CREE-LM80测试报告

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

XLamp XP-E White LEDs (Revision 1)

1. Number of LED light sources tested /LED光源

数量试验

See individual test reports.见测试报告

2. Description of LED light sources LED光源的描述XLamp XP-E White LEDs (XPEWHT)

All measurements provided are LED package measurements.

3. Description of auxiliary equipment测试设备描述Instrument Systems ISP-500 Integrating Sphere

Instrument Systems CAS-140 Spectrometer Keithley 2420 Sourcemeter

4. Operating cycle 循环周期LED packages are driven at constant current.

5. Ambient conditions 环境条件LED packages are operated in environmental

control chambers. The temperature of the

ambient air around the LED packages is actively

controlled by air flowing through the chamber.

TA : See individual test reports

RH : < 45%

Air flow : 800 CFM 包装是运作了环境控制室。周围

的空气的温度在LED包是乘飞机主动控制流过室。

助教:看个人测试报告

湿度,< 45%

空气流动:800 CFM立方英尺每分钟

6. Case temperature情况下温度The case temperature measurement point is shown in

the XLamp XP-E Soldering & Handling document

(AP25). 如此的温度测量点被证明在XLamp XP-E焊

接和处理文件(AP25)。

7. Drive current of the LED light source during lifetime test. LED驱动电流See individual test reports. The drive current used during lifetime testing is listed as “Drive Current.”看个人测试报告。驱动电流用在一生的测试被列为“驱动电流。”

8. Initial luminous flux and forward voltage at photometric measurement current 最初的光通量和正向电压¬度量测量电流在照片See individual test reports. The drive current used for luminous flux, forward voltage and chromaticity measurements is listed as “Measure-ment Current.” 看个人测试报告。用于驱动电流的光

Revision: 1 (September 20, 2010)

Test Summary Data Set

Case Temp. [TS] Ambient

Temp. [TA]

Drive

Current [IF]

Average Lumen Maintenanc e at 6,000 hours

Average Chromatici ty Shift (Δu’v’) at 6,000 hours 1 45°C 45°C

700 mA

97.7% 0.0012 2 55°C 55°C 700 mA 99.3% 0.0011 3 85°C 85°C 350 mA 97.9% 0.0006 4 85°C

85°C

700 mA

96.6%

0.0015

通量,正向电压测量及色度¬被列为“措施的观点电流。”

9. Lumen maintenance data for each individual LED light source 维护数据腔为每个LED 光源的

See individual test reports. Ambient temperature during luminous flux testing set to 25°C ±2°C. 看个人测试报告。 在环境温度测试集光通到25°C±2°C 。

10. Observation of LED light source failures 观察LED 光源的失败

No failures occurred during testing. 没有失败发生。

11. LED light source monitoring interval LED 光源的监测的时间间隔

See individual test reports.

12. Photometric measurement uncertainty 光度测量不确定度

Cree maintains a tolerance of +/- 2.0% on flux measurements for LM-80 testing. Cree 保持一颗宽容+ / - 2.0% LM-80流量测量测试。

13. Chromaticity shift reported over the measurement time 色度变化测量报导

See individual test reports.

Ambient temperature during chromaticity testing set to 25°C ±2°C. 看个人测试报告。 环境温度色度测试集在25°C±2°C 。

相关文档
最新文档