©KROHNE 03/20027.02425.21.00GRElectromagneticFlowmetersVariable area flowmetersVortex flowmetersFlow controllersElectromagnetic flowmetersUltrasonic flowmetersMass flowmetersLevel measuring instrumentsCommunications technologyEngineering systems & solutionsSwitches,counters,displays and recordersHeat meteringPressure and temperatureApplicationKROHNE electromagnetic flowmeters are to be found in many industrial sectors and applications.Just a small selection:G Chemical industry G Water and wastewaterGHydraulic transport,liquid products with up to 50% solids content G Paper and woodpulp production G Pharmaceutical G Food and beveragesG Filling and dispensing processes G Highly abrasive slurriesG High-pressure industrial processes GPartially filled pipelinesand many,many other applications in other industriesFIT and FORGET !All electromagnetic flowmeters are delivered ready for operation.Install the flowmeter in the pipeline,make the electrical connection,that's it.Always one step ahead with KROHNEThis highly accurate measurement technology is available with integrally or remote mounted converter,some with measuring errors of less than 0.2% of the measured value.The primary head is installed in the pipeline,while the signal converter for signal processing is remote mounted in a field housing or 19" plug-in unit.In the integral system,the signal converter is mounted in a housing with high protection category directly on the primary head.With meter sizes of DN2.5 - 3000 / 1/10" - 120",measurements can be carried out from 2l/h to 300 000m3/hand more.Most of the devices are approved for use in hazardous locations.Various materials are available for the measuring tube,liner and electrodes of the flowmeters for most applications. Electromagnetic flowmetersProduction and calibrationAll electromagnetic flowmeters from KROHNE meet the requirements of CE directives and EMC guidelines.Fabrication and production shops are certified to ISO 9001.At KROHNE,all electromagnetic flowmeters are calibrated by direct comparison of volumes,the most accurate calibration method of all.The KROHNE calibration rigs are the world's biggest and most accurate,and are accredited to EN17 025.Measurement uncertainty is less than 0.013% of themeasured value for meter sizes up to DN 3000 / 120" and above.7Electromagnetic flowmeters >0.05 µS /c m >5 µS /c m >20 µS /c m >50 µS /c mD N 2.5,4,6 1/10”,1/6”,1/4”D N 10 3/8”D N 32 11/2”Signal converterDatenblätterF l a n g e c o n n e c t i o n s F l a n g e l e s s ‘s a n d w i c h ’d e s i g n C h e m i c a l s W a t e r a n d s e w a g e P a r t i a l l y f i l l e d p i p e s P h a r m a c e u t i c a l s ,s a n i t a r y B a t c h i n g (1-10s )V e r y a b r a s i v e s l u r r i e s H i g h p r e s s u r e 2- o r 2 x 2-w i r e s y s t e mG e n e r a l p u r p o s e S a n i t a r y c o n n e c t i o n s H A R T ®/R S 485 (s t a n d a r d )P r o f i b u s P A H A R T ®/R S 485 (o p t i o n )H A R T ® (o p t i o n )O t h e r s o n r e q u e s t m Ao u t p u t ,2 w i r e c o n n e c t i o n ≤3 W ≤5 V A / ≤4.5 W ≤10 V A / ≤8 W ≤15 V A / ≤15 W ≤50 V A 2o r 2 x 2-w i r e s y s t e m 24,48,100 – 240 V A C ,48– 63 H z 24 V D C 24 V A C / D C 100 – 230 V A C ,48 –63 H z L i q u i d s ,p a s t e s S l u d g e a n d s l u r r i e s % s o l i d s /v o l u m e ≤3%S l u d g e a n d s l u r r i e s % s o l i d s /v o l u m e ≤5%S l u d g e a n d s l u r r i e s % s o l i d s /v o l u m e ≤30%P u l s a t i n g f l o w ,< 200 p u l s e s /m i n B a t c h i n g p r o c e s s > 1.5 s P a p e r a n d p u l p H y d r a u l i c t r a n s p o r t (o r e d r e s s i n g )o n l y I F C 090 K -C A P C a p a c i t i v e s i g n a l p i c k u p F ou n d a t i o n F i e l d B u s F A D N 251”D N 40 11/2”D N 502”D N 803”D N 1004”D N 1255”D N 1506”D N 2008”D N 25010”D N 30012”≤D N 1800≤72”≤D N 3000≤120”I S O f i t t i n g l e n g t h o n l y I F C 110 P F a n d I F C 210 E -P F P a r t i a l l y f i l l e d p i p e s ,AQUAFLUXECOFLUX 1000ALTOFLUX 2000ALTOFLUX 4000PROFIFLUX 5000VARIFLUX 6000ALTOFLUX 2W 2 wireBATCHFLUXCAPAFLUXTIDALFLUX partially filledALTOFLUX IFS 2005 FALTOFLUX IFS 4005 FALTOFLUX M 900IFC 010 K,FIFC 020 K,F ,EIFC 040 K 2 wireIFC 090 K,F IFC 090 K-CAP IFC 110 F IFC 110 PFIFC 210 E IFC 210 E-PFSC 150 FBatchflux IFC 012 KElectrical conductivitySizesConnectionsApplications (examples)Flow measurements (examples)Power supply Power consuptionInterfacesIFM 1080 KG Flangeless versionG Rugged measuring tube withstainless steel reinforced 080 KG Flanged connectionsG Steel housingµP-signal converter in plasticsIFM 4080 KG Flanged connectionsG Steel housingTeflon® PFA liner,reinforced withIFM 5080 KG Flangeless versionG Stainless steel housing The only precision flowmeter IFM 6080 KG Various sanitary/flangedconnectionsStainless steel housingG Precision flowmeterG With capacitive signal pickup(electrodes not in contact withG Flangeless versionG Rugged measuring tube withstainless steel reinforced G Flanged connectionsG Steel housingG Liner of Polypropylene,NSF-G Flanged connectionsG Steel housingG Teflon® PFA liner,reinforced withG Flangeless (sandwich) designG Stainless steel housingG The only precision flowmeter with G Flanged connectionsG Steel housingG Measuring tube made of Al2O3G Various sanitary/flanged connec-tions,stainless steel housingG FDA approved Teflon® PFA liner,G Designed for partially filled pipelinesG Excellent measuring accuracy,for low levels,through the integratedG IFC 010 K/IFC 020 K of integral design G IFC 010 F/IFC 020 F in field housing G IFC 020 E 19”plug-in version.G IFC 090 K of integral designG IFC 090 F in field housingG Signal processing by microprocessor,G Signal converter in field housingG Signal processing by microprocessor,outstanding interference rejection,G Signal converter in field housing for wall mounting G Signal processing by microprocessor,outstanding interference rejection,T o w e r h e i g h t 43 m e q u i v a l e n t t o 141 f t / n e t v o l u m e 350000 l i t r e s e q u i v a l e n t t o 95000 U S G a lPrecisionLM28 precision level switches control the flow volume and various computer-aided volume totalizersQmInlet run ≥10 ×DN (DN = meter size)©G The world’s largest and most accurate calibration rigGCalibration of flowmeters up to DN 3000 / 120”GCalibration by direct comparison of volumes,altogether the most accurate method GComparison measurements with so-called master meters are much less accurate and cannot be verifiedGThe volume measurement standards ofKROHNE calibration rigs have been calibrated by NMI,the Netherlands Standards Institute.Measurement uncertainty is less than 0.013% of the measured value.GKROHNE Altometer calibration rigs are accredited in conformity with EN 17 025.GCalibration accuracy is better than 99.97% of the measured value.GThe error of measurement of the calibration rigs is better by a factor of 10 than theaccuracy data of the flowmeter being tested.GAll flowmeters are calibrated underreference conditions,similar to EN 29 104.GAll calibration data are genuine and verifiable; documented in writing in the calibration reports,which are supplied together with each KROHNE flowmeter.An example is shown on the right.E r r o r o f m e a s u r e m e n t [% o f m e a s u r e d v a l u e ]Flow rate [m 3/h]0,50,402000400060008000100000,30,20,10,0-0,1-0,2-0,3-0,4-0,5+ 0.03%Accuracy inspires confidenceAt this flowrate,a typical public swimming-pool can be filled in less than 1 minute.Inaccuracy is less than 0.013% in terms of volume and less than 0.26 mm in terms of filling level (equal to the thickness of a single hair),based on an average pool depth of 2 metres.Flowmeters up to DN 3000/120”creates theKROHNE standardOutlet run ≥2 ×DN (DN =meter size)Volume flow rate Q max = 40 000 m 3/h= 11 m 3/sMeasuring Principle 3.1The induced voltage signal is picked up either by two measuring elec-trodes in conductive contact with the medium or indirectly bycapacitive coupling.A signal converter amplifies the signal and convertsit into a standard analog signal (e.g.4 to 20 mA) and a frequencysignal (e.g.1 pulse for every US gallon or cubic metre of mediumflowing through the measuring tube).To ensure that the voltage is not short-circuited by the pipe wall,themeasuring tube is made of an electrically insulating material or fittedwith an insulating liner.Measurement is largely independent of the flow profile and other prop-erties of the medium,such as pressure,temperature,viscosity,density,consistency,electrical conductivity,and electrode contamination.Measuring systemsThe electromagnetic flowmeter consists of a primary head,that isinstalled in the pipeline,and a signal converter.The compact design has the signal converter mounted directly on theprimary head.For systems with pulsed d.c.field the primary head field coils whichgenerate the magnetic field are energized by a pulsed direct currentfrom the signal converter.The measuring signal is a squarewave voltage of the same frequency.These systems feature extremely small measuring errors. Electromagnetic flowmeters measure the volume flow of electricallyconductive liquids and slurries.Measuring principleAn electric conductor,in this case the electrically conductive medium,passes through a magnetic field.The voltage U induced in this mediumis directly proportional to the mean flow velocity v.Magnetic inductionB (magnetic field strength) and the distance between electrodes D(nominal pipe diameter) are constant.K instrument constantB magnetic field strengthv mean flow velocityD electrode spacingThe volumetric flow rate qv can be calculated according toTherefore:q v=U x D xπ(4)K x B4The reducing angle (α) should not exceed 8°(equivalent to α/2 = 4°),otherwise measuring accuracy may be affected.If the reducing angle is greater,a straight inlet section must be fitted between reducing socket and primary head.Expanding sectionPressure Loss CalculationFor the expanding section,the optimum angle of expansion is α= 8°.ζat α= 8°d1/d2 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0ζ10.0180.0230.02550.0280.030.03080.03150.03230.0332Recommendations for installationSelection of meter sizeThe size of primary head should if possible be selected to provide a velocity of 2 to 3m/s or 6 to 9ft/sec.for the full-scale range. Minimum full-scale range is 0.5m/s or 1.5ft/sec.,maximum is 10 or 11m/s or 30 or 33ft/sec.,depending on flowmeter type.For fluids with a solids content,the velocity should be between 3 and 5m/s or 9 and 15ft/s to prevent deposits and minimize abrasion.Exact determination of flow velocityFor range setting purposes,the exact flow velocity can be determined using the flow table for each nominal pipe width.Example: v in m/sNominal pipe diameter DN150Desired measuring range200m3/hFrom the table we obtain for the flow velocity of 1m/sa flow rate of 63.617m3/h at DN150; for 200m3/hthe flow velocity v is:Example: v in ft/sNominal pipe diameter6”Desired measuring range1000 US GPMFrom the table we obtain for the flow velocity of 1ft/sa flow rate of 88.128 US GPM at 6”meter size;for 1000 US GPM the flow velocity v is:Flow tablesv = 1m/sMeter size Flow rate Meter size Flow rate DN mm m3/h DN mm m3/h2.50.017671250176.71 40.0452********.47 60.10179350346.36 100.28274400452.39 150.63617500706.86 20 1.131********.9 25 1.76717001385.4 32 2.89538001809.6 40 4.52399002209.2 507.068610002827.4 6511.94612004071.5 8018.09614005541.8 10028.27416007238.2 12544.17918009160.9 15063.617200011310 200113.10v = 1ft/sMeter size Flow rate Meter size Flow rate inch US GMP inch US GMP1/100.024********.801/80.03825012352.511/40.1530014479.813/80.3442516626.69 1/20.6120020979.21 3/4 1.3770241410.1 1 2.4480281919.211/4 3.8250322506.8 11/2 5.5080363172.6 29.7921403916.8 21/215.300485640.2 322.032567677.0 439.1686410027 561.2007212691 688.1288015667 8156.67Protection classes to IEC 529/EN 60529。

电磁流量计的优点和缺点,你知道吗

电磁流量计的优点和缺点,你知道吗

电磁流量计的优点和缺点,你知道吗电磁流量计是根据法拉第电磁感应定律制成的一种测量导电性液体介质流量的仪表。

电磁流量计有一系列优良特性,可以对脏污流、腐蚀流的进行测量。

电磁流量计的优点:
(1)测量通道是段光滑直管,不会阻塞,适用于测量含固体颗粒的液固二相流体,如纸浆、泥浆、污水等。

(2)不产生流量检测所造成的压力损失,节能效果好。

(3)所测得体积流量实际上不受流体密度、粘度、温度、压力和电导率变化的明显影响。

(4)流量范围大,口径范围宽。

(5)可应用腐蚀性流体。

电磁流量计的缺点:
(1)有一定局限性,它只能测量导电介质的液体流量,不能测量非导电介质的流量。

(2)安装与调试比其它流量计复杂,且要求更严格。

安装地点不能有振动,不能有强磁场。

安装时必须使变送器和管道有良好的接触及良好的接地。

在使用时必须排尽测量管中存留的气体,否则会造成较大的测量误差。

(3)用来测量带有污垢的粘性液体时,粘性物或沉淀物附着在测量管内壁或电极上,电极上污垢物达到一定厚度,可能导致仪表无法测
量。

电磁流量计广泛应用在油气田注水、污水处理、造纸、市政给排水等领域。

科隆电磁流量计修改系数

科隆电磁流量计修改系数

科隆电磁流量计修改系数
【原创实用版】
目录
1.科隆电磁流量计简介
2.科隆电磁流量计的修改系数
3.修改系数对科隆电磁流量计的影响
4.如何修改科隆电磁流量计的系数
5.结论
正文
科隆电磁流量计是一种用于测量导电介质的流速、电导率、体积流量和质量流量的仪器。

它具有安装和启动简便、自诊断功能以及信号转换快等特点,因此被广泛应用于化工、环保、冶金、医药、造纸、给排水等工业技术和管理部门。

科隆电磁流量计的修改系数是指在测量过程中,为了提高测量精度,对原始数据进行修正的一个参数。

这个系数可以通过调整流量计的参数来修改。

修改系数对科隆电磁流量计的影响非常大,如果修改不当,可能会导致测量结果不准确。

那么,如何修改科隆电磁流量计的系数呢?一般来说,科隆电磁流量计的修改系数包括两个部分:GK 值和 GKL 值。

其中,GK 值是流量系数,修改 GK 的大小可以调整流量的大小;而 GKL 值是线性校正系数,修改GKL 值可以调整流量计的测量精度。

在修改系数时,需要根据实际情况来进行调整,以保证测量结果的准确性。

总之,科隆电磁流量计的修改系数对于测量结果的准确性具有重要影响。

因此,在使用科隆电磁流量计时,需要对修改系数进行适当的调整,以提高测量精度。

电磁流量计工作原理及特点

电磁流量计工作原理及特点

电磁流量计工作原理及特点
电磁流量计是一种利用电磁感应原理来测量导体内液体流量的仪表。

它由两个主要部分组成:测量管和传感器。

1. 工作原理:
电磁流量计通过施加一个垂直于流动液体方向的磁场,并测量液体中感应出的电动势来测量液体的流量。

当导体内液体流动时,垂直于流动方向的磁场会产生涡流。

涡流的大小与导体内液体流速成正比。

根据法拉第电磁感应定律,涡流会在导体内产生电动势。

根据电动势的大小,可以计算出液体的流量。

2. 特点:
a. 非侵入式:电磁流量计不直接接触流动液体,因此不会对流动液体造成阻力或压力损失。

b. 强大的适应能力:电磁流量计可以测量各种导电液体,包括腐蚀性液体、污水、石油等。

c. 精度高:电磁流量计具有较高的精度,通常可达到0.5%。

d. 宽测量范围:电磁流量计可测量的流量范围广,通常可覆盖
0.01m/s至25m/s的速度范围。

e. 无移动部件:电磁流量计没有移动部件,因此维护成本低、响应时间快。

f. 成本效益高:电磁流量计的制造成本相对较低,且可以长期稳定运行。

需要注意的是,电磁流量计只能测量导电液体,并且对于含有气泡或颗粒物质的液体流量测量具有一定的局限性。

此外,电
磁流量计在安装时需要考虑导体与仪表之间的绝缘,以防止磁场发生干扰。

电磁流量计流速计算公式

电磁流量计流速计算公式

电磁流量计流速计算公式
一、电磁流量计原理。

电磁流量计是根据法拉第电磁感应定律来测量管内导电介质体积流量的感应式仪表。

当导体在磁场中做切割磁力线运动时,在导体的两端将产生感应电动势,其方向由右手定则确定,其大小与磁场的磁感应强度、导体在磁场内的有效长度及导体的运动速度成正比。

1. 法拉第电磁感应定律基础公式。

- 设磁场的磁感应强度为B,导体(这里是导电液体流束)在磁场中的有效长度为L,液体的流速为v,则产生的感应电动势E为:E = BLv。

2. 电磁流量计中流速与流量的关系。

- 对于圆形管道,设管道内径为D,则流束的有效长度L = D。

- 流量Q(体积流量)与流速v的关系为Q=π((D)/(2))^2v=(π D^2v)/(4),可以推出v = (4Q)/(π D^2)。

- 又因为E = BLv,在电磁流量计中B、L = D是已知的仪表参数,当感应电动势E被测量出来后,由E = BDv可得v=(E)/(BD)。

- 如果要通过流量Q来表示感应电动势E,将v=(4Q)/(π D^2)代入E = BDv 中,得到E = BD×(4Q)/(π D^2)=(4BQ)/(π D)。

所以,电磁流量计中流速v的计算公式为v=(E)/(BD)或者v = (4Q)/(π D^2)。

其中E为感应电动势,B为磁感应强度,D为管道内径,Q为体积流量。

电磁流量计原理

电磁流量计原理

电磁流量计原理电磁流量计是一种通过测量流体对磁场的干扰来测量流量的仪器。

电磁流量计具有精度高、稳定性好、无需移动零件、试验损失小等优点,广泛应用于化工、石油、冶金、水利等行业中的流量测量。

电磁流量计的原理是基于法拉第电磁感应定律,即当导体在磁场中运动时,导体内部会产生电动势。

当流体经过电磁流量计的测量管时,流体作为导体,会产生运动,所以在测量管的周围产生一个交变磁场。

同时,在测量管两端引入一对电极,当流体流过的时候,由于导体内部的电阻,会形成一个电场,因此在管道两端的电极之间会产生一个电压信号。

由于电磁流量计测量管内部的电导率是固定不变的,因此随着流体流过测量管,流体对于周围磁场的干扰也是固定不变的。

因此,只需要测量电极之间的电压信号的大小,就可以计算出流量的大小。

具体来说,电磁流量计的测量原理分为两个部分,即磁场的产生和电场的检测。

电磁流量计的磁场产生可以通过感应线圈来实现,感应线圈产生的磁场可以是交变的,也可以是恒定的。

在测量管内部安装一对电极,电极之间测量出的电压信号与流体流动有关。

在实际应用中,可以通过不同的方法来测量电压信号的大小,例如使用电压表或连接到计算机等等。

在电磁流量计的应用过程中,需要注意的是,不同的流体会对磁场产生不同的干扰,因此需要对不同的流体进行针对性调整,以保证测量结果的准确性。

同时,由于测量管的几何形状和流体流动速度的差异,不同型号的电磁流量计也需要经过特定的校验和调整才能达到精确测量的效果。

总之,电磁流量计是一种基于法拉第电磁感应定律的流量测量仪器,采用交变磁场和电场检测的方式来测量流体的流量。

它具有精度高、稳定性好、无需移动零件、试验损失小等优点,广泛应用于化工、石油、冶金、水利等行业中的流量测量。

电磁流量计怎么用

电磁流量计怎么用

电磁流量计怎么用电磁流量计是一种用于测量管道内液体流量的常见设备,它通过应用法拉第电磁感应原理来确定导电液体内的流速。

使用电磁流量计可以实现准确的流速测量,适用于各种工业应用领域。

下面将详细介绍电磁流量计的使用方法。

步骤一:安装电磁流量计1.将电磁流量计安装在要测量的管道上。

确保安装方向正确,传感器与管道呈90度角,并且没有倾斜。

2.确保电磁流量计的电气连接正确,接好电源线和信号线。

3.对电磁流量计进行初始化设置,如输入流体参数、管道直径等。

步骤二:设置流量计参数1.打开流量计设备的电源,进入设备设置菜单。

2.在设备设置菜单中,输入流体密度、流速范围,根据实际情况设置输出信号类型和量程。

3.确认设备参数设置无误后保存并退出设置菜单。

步骤三:校准电磁流量计1.使用标准流量计或知名流速测量仪器对电磁流量计进行校准。

2.根据实际测量情况,对电磁流量计进行手动或自动调零和调校。

3.确认校准结果准确无误后,即可进行正式的流量测量。

步骤四:实际使用1.开启电磁流量计的测量功能,观察流速显示。

2.监测流速变化,根据需要调整参数或操作。

3.定期清洁和维护电磁流量计,确保其长期稳定的测量性能。

注意事项1.电磁流量计只适用于导电液体的流速测量,不适用于非导电液体或气体。

2.在使用过程中,避免电磁流量计受到强磁场干扰,影响测量准确性。

3.定期对电磁流量计进行检查和校准,确保测量结果的准确性和可靠性。

通过以上步骤,您可以成功地使用电磁流量计进行准确的流速测量,为工业生产和流程控制提供可靠的数据支持。

电磁流量计的优缺点

电磁流量计的优缺点

电磁流量计的优缺点电磁流量计是一种常见的流量计,它基于法拉第电磁感应定律,通过对流体中感应电势的测量来确定其流量。

在很多应用中,电磁流量计是一种可靠且准确的选择。

然而,电磁流量计也有其优缺点。

优点宽测量范围电磁流量计可以测量很宽范围内的流量,从微弱的几微升每小时到大流量的几百升每分钟,从液体到气体,它们都可以胜任。

高度准确性相比于其他类型的流量计,电磁流量计通常拥有更高的准确度。

因为它们根据物理定律进行测量,而不是通过简单的近似估计方法得出结果。

接头稳定性电磁流量计中使用的接头通常比其他类型的流量计更稳定。

这些接头设计精细,能够很好地保持线路的完整性,从而保证数据的准确性。

维护简单电磁流量计内部部件结构简单,清洁和维护相对简单。

维修零件容易获得,而且大量的服务商为用户提供了维护、校准等服务。

缺点灵敏度电磁流量计较为灵敏,因此需要一定的运行条件和维护保养,例如对电源品质的要求高,负载会影响电压输出等。

环境适应性受外部环境影响,如强电磁干扰,气温参差不齐等,可能导致数据变化或者不准确。

因此使用时需要一定的环境条件,以保证测量数据的稳定和准确。

成本高相对于其他类型的流量计,电磁流量计的成本更高。

自生产、组装、维护等成本等因素,让其价格相对更高。

可靠性虽然电磁流量计的部件简化,但是设备太过于复杂和高灵敏度,需要对材料和工艺有较高的物理学和电学需求,如果因失工或质量监控等原因,所引发损耗也较高。

结论电磁流量计是一种高度准确的流量计,可应用于广泛的流体类型和流量范围,但也存在一些局限性。

在实际应用中,需要考虑不同的使用环境和流量测量要求,并评估其优缺点,才能选择最适合的测量方法和设备。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

电磁流量计简介
1、电磁流量计介绍及电磁流量计工作原理
流量传感器是把流过管道内的导电液体的体积流量转换为线性电

信号。其转换原理就是著名的法拉第电磁感应定律,即导体通过磁场,
切割电磁线,产生电动势。流量传感器的磁场是通过励磁实现的,分
直流励磁、交流励磁和低频方波励磁。现在大多流量传感器采用低频
方波励磁。变送器是由励磁电路、信号滤波放大电路、A/D采样电
路、微处理器电路、D/A电路、变送电路等组成。工作原理电磁流
量计(EletromagneticFlowmeters,简称EMF)是20世纪50~60年
代随着电子技术的发展而迅速发展起来的新型流量测量仪表。电磁流
量计是根据法拉第电磁感应定律制成的,电磁流量计用来测量导电液
体体积流量的仪表。由于其独特的优点,电磁流量计目前已广泛地被
应用于工业过程中各种导电液体的流量测量,如各种酸、碱、盐等腐
蚀性介质;电磁流量计各种浆液流量测量,形成了独特的应用领域。
在结构上,电磁流量计由电磁流量传感器和转换器两部分组成。传感
器安装在工业过程管道上,它的作用是将流进管道内的液体体积流量
值线性地变换成感生电势信号,并通过传输线将此信号送到转换器。
转换器安装在离传感器不太远的地方,它将传感器送来的流量信号进
行放大,并转换成流量信号成正比的标准电信号输出,以进行显示,
累积和调节控制。电磁流量计的基本原理(一)测量原理根据法拉第
电磁感应定律,当一导体在磁场中运动切割磁力线时,在导体的两端
即产生感生电势e,其方向由右手定则确定,其大小与磁场的磁感应
强度B,导体在磁场内的长度L及导体的运动速度u成正比。
2、优点
EMF的测量通道是一段无阻流检测件的光滑直管,因不易阻塞适

用于测量含有固体颗粒或纤维的液固二相流体,如纸浆,煤水浆,矿
浆,泥浆和污水等.EMF不产生因检测流量所形成的压力损失,仪表
的阻力仅是同一长度管道的沿程阻力,节能效果显著,对于要求低阻
力损失的大管径供水管道最为适合.EMF所测得的体积流量,实际上
不受流体密度,粘度,温度,压力和电导率(只要在某阈值以上)变化
明显的影响.与其他大部分流量仪表相比,前置直管段要求较低.
EMF测量范围度大,通常为20:1~50:1,可选流量范围宽.满度值液
体流速可在0.5~10m/s内选定.有些型号仪表可在现场根据需要
扩大和缩小流量(例如设有4位数电位器设定仪表常数)不必取下作
离线实流标定.EMF的口径范围比其他品种流量仪表宽,从几毫米
到3m.可测正反双向流量,也可测脉动流量,只要脉动频率低于激磁
频率很多.仪表输出本质上是线性的.易于选择与流体接触件的材料
品种,可应用于腐蚀性流体.
3、缺点
EMF不能测量电导率很低的液体,如石油制品和有机溶剂等.不

能测量气体,蒸汽和含有较多较大气泡的液体.通用型EMF由于衬
里材料和电气绝缘材料限制,不能用于较高温度的液体;有些型号仪
表用于过低于室温的液体,因测量管外凝露(或霜)而破坏绝缘.
4、
分类
市场上通用型产品和特殊型仪表可以从不同角度分类.如按激
磁电流方式划分,有直流激磁,交流(工频或其他频率)激磁,低频矩形
波激磁和双频矩形波激磁.按输出信号连线和激磁(或电源)连线的
制式分类,有四线制和二线制.按转换器与传感器组装方式分类,有
分离型和一体型.按流量传感器与管道连接方法分类,有法兰连接,
法兰夹装连接,卫生型连接和螺纹连接.按流量传感器电极是否与被
测液体接触分类,有接触型和非接触型.按流量传感器结构分类,有短
管型和插入型.按用途分类,有通用型,防爆型,卫生型,防侵水型和
潜水型等.
5、
应用概况

EMF应用领域广泛.大口径仪表较多应用于给排水工程.中小口
径常用于固液双相等难测流体或高要求场所,如测量造纸工业纸浆
液和黑液,有色冶金业的矿浆,选煤厂的煤浆,化学工业的强腐蚀液以
及钢铁工业高炉风口冷却水控制和监漏,长距离管道煤的水力输送
的流量测量和控制.小口径,微小口径常用于医药工业,食品工业,生
物工程等有卫生要求的场所.

相关文档
最新文档