SARTORIUS MA150ⱘ ԰ ⊩˖ ⼎˖

⊼˖Џ㽕 䆒㕂⿟ ˈ Ҫⱘϰ㽓ϔ㠀ϡ䳔㽕

䗝 PROGRAM˄⿟ ˅

enter䖯 㦰 ⼎˖Heating Program( ⛁⿟ )

Standby temperature( ⏽ )

Bar graph for weighing-in sample(ḋ ⿄䞡 㒓 )

Start analysis( )

End of analysis end( ⊩ )

Display mode (⌟䞣㒧 ⼎῵ )

Print intermediate resuts( 㒧 )

Factory setting( 䆒㕂)

1˅Heating Program⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter䖯 㦰 ˈ䗝 Heating Program enter ⼎Standard drying˄ ⛁˅ enter ⼎Temperature 105ćˈ 䴶 ϞⱘϞϟ䬂 ҹ䇗㡖⏽ DŽ

Heating Program⿟ 䇈 ˖䆒 ԰ⱘ ⛁⏽ ˈ ҹḍ ḋ 䳔㽕ⱘ⏽ 䖯㸠䆒 ˈ⏽ 㣗 ˖40ćˉ ćˈҹ ć䖯㸠䇗 DŽ

2˅Standby temperature⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter䖯 㦰 ˈ䗝 Standby temperature enter ⼎OFF˄ ˅/ON( ) ,䗝 ON ҹ䆒

TemperatureЎ䳔㽕 ⏽ⱘ䇏 ˈ Ϟϟ䬂䇗 ⏽ DŽ

Standby temperature⿟ 䇈 ˖ 䖲㓁ⱘḋ 䳔㽕⌟䆩ˈ ҹ ㄝ 㺙ḋ ⱘ 䯈ϔⳈ 䆒 ⱘ⏽ DŽ

3˅Bar graph for weighing-in sample⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter䖯 㦰 ˈ

䗝 Bar graph for weighing-in sample enter ⼎Inactivated

Actiivaed

䗝 Inactivated㸼⼎ϡ䆒㕂

䗝 Actiivaed enter䬂 ⼎Target wt :hh g㸼⼎ ⱘḋ ⫼䞣ˈ 䗝 䖭Ͼ⿟ ˈ Ϟ ҹ ⼎ḋ ⱘ ḋ䞡䞣 ⱘ DŽ 䝦ḋ ḋⱘ DŽ

Bar graph for weighing-in sample⿟ 䇈 ˖ ⌟䆩 䳔㽕 ϔ 䞡䞣ⱘḋ ˈ ҹ䆒 ⱘ ḋ䞣ˈ 䝦 㕂ḋ ⱘ DŽ

4˅Start analysis⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter䖯 㦰 ˈ

䗝 Start analysis enter ⼎

With stability ,after Enter ket (ⲪϞⲪ〇 ˈ enter )

OW/O stability , after closing˄ϡ䆎〇 Ϣ ˈⲪϞⲪ ˅

Start analysis⿟ 䇈 ˖Џ㽕 ⱘ䗝

5˅End of analysis end⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter䖯 㦰 ˈ

䗝 End of analysis enter ⼎Automatic(㞾 )

Semi-automatic˄ 㞾 ˅

End of analysis end⿟ 䇈 ˖Џ㽕 ⱘ䗝 DŽ

䗝 Automaticҷ㸼ḋ ⌟䆩 㞾 ℶˈ

䗝 Semi-automaticˈҷ㸼 㞾 ⱘ DŽ enter ⼎loss/24S:hh g˄㸼⼎24S ∈ ˈ ҹ⫼Ϟϟ䬂䇗㡖 ˅ˈ䇗㡖 ҹ ˈ ⴔ ⼎Time enter䬂 ⼎hh minDŽ

6˅Display mode ⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter 䖯 㦰 ˈ

䗝 Display mode enter ⼎

Moisture (%M)-------∈ӑ

Solids (%S)-------- 䞡

Patio (%MS)------↨

Weight loss (mg)------ ∈ӑ

Residue (g)-------⚬ 䞡䞣

Display mode ⿟ 䇈 ˖䗝 ⱘ㒧 ⼎῵ ˈ ҹ ϞⳈ㾖ⱘ ⼎ ˈг ҹ Ϟϟ䬂䗝 䳔㽕 ⼎ⱘⱘ㒧 ῵ DŽ

7˅Print intermediate results⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter 䖯 㦰 ˈ䗝 Print intermediate resultsˈ enter ⼎OFF/ON

Print intermediate results⿟ 䇈 ˖ ⿟ ˈ ϡ䳔㽕 ⱘ䆱䗝 OFF, 䳔㽕 ҹ䌁фDENVERⱘ Ⳉ 䖲ϞIR60 DŽг ҹ䗮䖛ҢDENVER 䌁ф⬉㛥

䕃ӊ 㒓ˈ䫒 ⬉㛥䗮䖛 䗮ⱘ DŽ

8˅Factory setting⿟ ⱘ䆒㕂ℹ偸˖䗝 PROGRAMˈ enter 䖯 㦰 ˈ

䗝 Factory settingˈ enter ⼎YES/NO

Factory setting⿟ 䇈 ˖ DŽ

В՟˖䆒 ԰⿟

⛁⏽ Ў120 ˈ ⛁ 䯈Ў5 䩳ˈ ⿄ḋ䞣5gˈ ЎⲪϞⲪ〇 , Ў5mg / 10S ˈ⌟䞣㒧 ⼎῵ ЎgDŽ

ℹ偸 䬂 ⼎

2ˊ䗝 PROGAM, PROGAM

3ˊ⹂䅸PROGAM P1 / P2 / P3 / P4 / P5

Heating Program

Standby temperature

Bar graph for weighing-in sample

Start analysis

End of analysis end

Display mode

Print intermediate resuts

Factory setting

˄ϔ˅䆒㕂 ⛁⿟ ˄ℸ՟Ё⏽ Ў120 ˈ ⛁ 䯈Ў5 䩳˅

1ˊ䗝 Heating Program O Heating Program

2ˊ⹂䅸Heating Program O Standard drying

3ˊ⹂䅸Standard drying Temperature 105ć

4ˊ䆒 ⛁⏽ 䞡 Temperature 1hhć(ℸ՟ЁЎ130 )