LWES-SL-PTCL-01065-NA-340-SHOWER CURTAINS-V19
Rise N Tilt淋浴马桶用户手册说明书

Rise N Tilt Shower CommodeThe world’s first shower commode that lifts and tilts the bariatric user to a 30° angle. A carefully considered and safe combination chair that takes both the user and the caregiver into consideration in any bathing situation.Rise N Tilt Shower Commode is used in care homes, institutions, and hospitals. User weight up to 325 kg.Cobi Rehab and Cobi Rehab suppliers comply with the UN conventionsUSER MANUALUP TO 325 KGScan or click on the code and •Brakes on all four wheels. •Washable in a cabinet washer.•Optional extra-wide butterfly arm rests. •Remote control provides the carer witheasy access to the electrical functions.•Ensures a better working environment for the carer and a comfortable and safe bathing experience for the user. •Adjustable seat height and seat depth. •Several types of leg rests.Table of content1. Safety (3)2. Explanation of symbols (4)3. General comments (5)4. Application (5)5. Use (6)6. Charging and operation (7)7. Actuators (8)8. Maintenance and cleaning (9)9. Transport and storage (9)10. Recycling and disposal (10)11. Warranty (10)12. Specifications (11)13. Accessories and spare parts (12)WARNINGDo not use the Rise N Tilt Shower Commode without thorough instruction from trained staff or from persons who have received instruction in the use of the shower commode. Improper operation may injure the user.Using the Rise N Tilt Shower Commode for people weighing more than the maximum user weight of 325 kg increases the risk of damaging the commode.Read this user manual carefully before using the Rise N Tilt Shower Commode. Pay particular attention to Safety Instructions marked .Cobi Rehab assumes no responsibility for any damage to the product nor for personal injury caused by incorrect installation, incorrect mounting, or incorrect use of the Rise N Tilt Shower Commode.Immediately contact Cobi Rehab if parts are damaged or missing. Never use your own spare parts.Cobi Rehab cannot be held responsible for errors or accidents occurring after repairs are made without written permission from Cobi Rehab.SAFETY INSTRUCTIONSIn this user manual, the symbol indicates a safety instruction. Follow safety instructions carefully.The caregiver staff assesses whether the user should be restrained in the Rise N Tilt during use for safety reasons.Always lift users not able to stand and walk in and out of the Rise N Tilt. Always take care when using the tilt-in-space and recline function to avoid jerky movements.The maximum user weight of the Rise N Tilt is 325 kg.The surface temperature can rise when the shower commode is exposed to external heat sources e.g., sunlight.Due to its large width, the Rise N Tilt Shower Commode may have difficulty passing through ordinary doorways and emergency exits. Always use helper control for users with impaired cognitive function. Always ensure that the wheelchair is charged.The charging cable must always be disconnected from the control box in bathing situations.Rise N Tilt Shower Commode may only be used on a flat, hard floor witha maximum inclination of 3 °. Larger slope increases the risk of tipping.1. Safety2. Explanation of symbolsCaution!Double insulated (class II)Declaration of conformity, Medical DeviceRegulation, EU 2017/745IPX6IP-classificationDispose of through correct waste managementCobi Catalogue numberSerial numberYear of manufactureManufacturerMedical deviceMax. user weightConsult the manualCE label located at the frame.See an example of an CE-label below.4. ApplicationThis user guide contains important information about the use of the Rise N Tilt Shower Commode and the target group for the shower commode. It also includes a wide range of specifications on the Rise N Tilt Shower Commode.The most recent version of this user guide can be found on our website. Check if the version you are reading now is the most recent.If you need a user guide that is written in a larger font size, the product sheet is available in PDF format at , which can be scaled up to the required font size.You can always contact Cobi Rehab on telephone +*************************************information about the Rise N Tilt Shower Commode.Cobi Rehab reserves the right to change the product specifications without providing prior notice.The UDI number of the shower commode appears on the label, which is located on the side of the frame.Product safety notices and product recalls can be viewed on the website.3. General commentsRise N Tilt Shower Commode is designed for indoor use in e.g., hospitals, care centres and institutions.The Shower Commode is intended for bariatric users of up to 325 kg with reduced physical functional capacity.Rise N Tilt Shower Commode is not intended for traversing obstacles such as door steps, etc. The shower commode should only be used on a firm surface to avoid the risk of tipping.The intended operator of the Rise N Tilt Shower Commode is a health professional, such as atherapist, nurse, or social and healthcare worker. Rise N Tilt Shower Commode can be used inenvironments with a temperature range of 0-40°C and a humidity interval of 20-80 %. ContraindicationsMonitor users with cognitive impairment while using the Rise N Tilt Shower Commode.5. UseBefore useThe arm rests must be correctly mounted in the holes on the side of the shower commode. The width of the foot rests may be gradually adjusted. Always mount the lock bolts under the foot rests correctly in the foot rest holes. The lock bolts must not be tightened against the foot rest outside the holes.Ensure that the seat is correctly mounted on the seat frame of the shower commode.Do not use the shower commode until both arm rests have been mounted. Without arm rests, the user may fall sideways.Rise N Tilt makes it easier for care staff to performdaily hygiene and care for skin and tissue.While in useThe user must not use the foot rests to stand on or as a step during transfer as this may lead to a risk of tipping. Risk of trapping- Mounting the arm rests while the user occupies the shower commode, may cause trappingbetween the arm rest and the side of the chair. - A foot may be trapped between the foot rests if the lock bolts are not correctly mounted in the foot rests.- Fingers and other body parts may be trapped between the seat frame of the shower commode and a toilet bowl or the bedpan. Therefore, always exercise great care when moving the shower commode above a toilet, or when the bedpan is inserted underneath the seat.- A caregiver’s hand may be trapped between the handlebar and the seat frame when the seat is inthe top-most position.Always make sure to brake at least two wheels when transferring the user to and from Rise N Tilt Shower commode and when the useroccupies the shower commode.When transporting the user, the seat must be lowered as far down as possible, as it may otherwise tip.The charging cable must always bedisconnected from the control box in bathing situations. Rise N Tilt is a unique combination of a commode chair and a shower chair.Bedpan with cover. Easy to insert and empty.6. Charging and operationBefore using the shower commode, the battery must be charged. The battery is located inside the control box which is mounted on the handlebar. Charging the battery takes up to 10 hours.When connecting the control box with the battery to the power supply, the yellow LED on the battery lights up. Once the battery has been charged, the yellow LED switches off.Once the charge is complete, all three LEDs on the remote control light up at the same time. Charging the shower commode every day after use is recommended. Low battery levelWith a 25% charge, the shower commode can only move downwards. This ensures that the user can always be lifted down. Hard strain on batteryIf the battery is heavily strained with manysuccessive up-and-down movements, the battery may become too hot, thus activating the safety thermostat inside the battery.This means that the control box will stop working. The battery must be allowed to cool down for at least 30 minutes before being used again. At least one minute must be allowed to pass before another battery is installed in the control. Always having a charged battery to hand is recommended.6.1 PreparationAccompanying battery for charging. Located in thecontrol bo x and charged directly from there.The Rise N Tilt Shower commode is equipped with four actuators located under the seat. These four actuators provide the lifting and tilting function of the shower commode. Please note that the battery must not be removed from the control box until five seconds after the last actuator has stopped. Should this occur, the bath-and commode chair must be calibrated. See section 7.1.If e.g., the two actuators that control the tilt have been lowered, the control box will shut these down. This also applies if the two actuators that control lifting run skewed, or if all four actuators run skewed at the same time.Should this occur, the shower commode must be calibrated. See section 7.1.7. Actuators If issues with operation arise, it is important to check that all plugs are correctly connected to the control box and the remote control as well as between the battery and the control box. If the actuators do not work, the shower commode must be 0-point calibrated.A 0-point calibration is performed by pressing the two bottom buttons of the remote control until the shower commode has reached ”b ottomposition ”. The calibration has not been completed and the actuators are able to move again. Charging errorIn case of charging errors, the yellow battery LED will blinks.1. Remove the lead from the power supply.2. Wait to minutes and reconnect the lead. If all LEDs blink, this is a signal of irregularities in the electrical functions of the shower commode. This requires a 0-point calibration:Press the two bottom buttons of the remote control until the shower commode has reached ”b ottom position ”.In case of other irregularities, please contact Cobi Rehabat+**************************.7.1 Calibrating the actuators using the remote controlThe Tilt Shower Commode frame, seat and armrests can be cleaned using water and a regular cleaning agent.The seat can be removed and disinfected using ethanol 70-85 % or a chlorine product of min. 1000 ppm and max. 10000 ppm.The Tilt Shower Commode can be washed in a cabinet washer tunnel in e.g., a hospital.The remote control and control box can be disinfected using ethanol 70-85 % or a chlorine product of min. 1000 ppm and max. 10000 ppm. Bolts and lock nuts must be regularly inspected and possibly retightened. Failure to inspect bolts may result in malfunction. Battery handlingAlways use batteries that are in good condition and fully charged when installed in the control box.Battery life can be extended by recharging it albeit if it is not entirely flat.If the control box is not to be used for a considerable period (days and weeks), the battery should be removed from the control box to prevent it from being completely discharged which could cause permanent damage to the battery.When the shower commode is not in use, store itin a dry place and between -10 – 40°C.The Rise N Tilt Shower Commode is suitable for land and/or air transport (without the user). The Rise N Tilt Shower Commode cannot be folded as the frame is fixed.To avoid injuries to e.g., the back, care staffshould refrain from carrying the 46 kg shower commode. If it is to be transported, the Rise N Tilt Shower Commode can be lifted by the frame, without the user being seated in it, into a motor vehicle.9. Transport and storageWhen storing the Rise N Tilt Shower Commode for a longer period (more than three months), store it in 0-40°C and a humidity not exceeding 80 %.It is recommended that the battery is charged to 60 % prior to storage. When putting the Rise N Tilt Shower Commode into use again after long-term storage, it must be connected to the power supply and charged for at least ten hours.Keep an eye on the battery capacity as the Rise N Tilt Shower Commode will discharge over time.9.1 Long-term storage8. Maintenance and cleaningDispose of products that are no longer in use in an environmentally safe manner.Contact your local authority or Cobi Rehab for further information on disposal. Contact Cobi Rehab for more information on the recycling of Lithium batteries and parts of the Rise N Tilt Shower Commode .Cobi Rehab warrants that the Rise N Tilt Shower Commode is without defects on delivery. If, against all expectations, the Rise N Tilt Shower Commode is subject to deficiencies or defects on receipt, please contact Cobi Rehab immediately. The warranty period for the Rise N Tilt Shower Commode is one year from the date of purchase and covers manufacturing defects or defect on receipt. The invoice is your certificate of warranty. The warranty does not apply to:- products on which the serial number, batch number or the like have been removed or significantly damaged.- products which have been repaired by unauthorised personnel. The warranty does not cover:- wearing parts.This warranty does not apply when Cobi Rehab assesses that the Rise N Tilt Shower Commode has been improperly operated.For damage caused by improper operation, an invoice will be issued for both the service and the spare parts used.Lack of maintenance can damage the product, shorten the life, or affect the performance of the Rise N Tilt Shower Commode.11. Warranty10. Recycling and disposalReport any incidents related to the use of the RiseN Tilt Shower Commode to Cobi Rehab.11.1 Unintended eventAfter the expected service life, it is important thatan overall assessment of the product is madebefore continued use.After the expected service life, Cobi Rehabcannot guarantee the suitability and safety of theproduct, as Cobi Rehab has no control over howthe product is used and wear and tear.The overall assessment of the product must becarried out by qualified professionals, and as aminimum, consideration must be given to how theproduct has been used, the condition of theproduct and its components.Cobi Rehab can always make such an assessment.11.2 After expiry of the expected service life12. SpecificationsMax. user weight 325 kg Risk class I Basic UDI DI 5740000100005N4 Expected product service life 7 years Expected battery service life 2-3 years Total length in low position 1400 mm Total width standard arm rests/butterfly arm rests 760/850 mm Seat width 610 mm Seat depth adjustable 420/480/540 mm Seat angle electric backwards 0-30° Seat angle independent of height adjustment Yes Width between standard arm rest/butterfly arm rest 610 mm/750 mm Width toilet opening Ø 240 mm, 350 mm long Seat height electric adjustable 550-1110 mm Distance from ground to seat underside 445 mm Distance from ground to pushbar1000 mm Distance from seat to foot rests390/420/450/480 mm Distance from seat to arm rests 220 mm Total weight of Rise N Tilt Shower Commode 46 kg Swing away arm rests Yes Foot rests and folding Yes Foot rests swing away, hight adjustable Yes Neck support Yes Lockable wheels Yes, 4 Up/down capacity with fully charged battery Approx. 15 times Turning radius 1560 mm Frame Powder-coated chrome molybdenum steel Wheels Ø150 mm with brake Seat/back/arm rests Polyurethane IP-classification IPX6 ISO-classification 09 12 03 - 23 Four actuators LINAK A20/A40Control box LINAK Remote control LINAK Risk assessment EN/ISO 14971: 2012 General requirements and test methods EN 12182:201213. Accessories and spare partsAccessory Part number Butterfly arm rest right (adds 7 cm width between the arm rest) 0150-999-012R Butterfly arm rest left (adds 7 cm width between the arm rest) 0150-999-012L Neck support adjustable 0156-999-020 Seat entirely with cover for shower commode 0150-999-023 Bedpan with cover plastic 0140-999-001 Foot rest standard shower commode right 0156-999-090H Foot rest standard shower commode left 0156-999-090V Lateral leg rest for shower commode right 0156-999-030 Lateral leg rest for shower commode left 0156-999-031 Battery for Rise N Tilt Shower Commode 0157-999-050MANUFACTURER Cobi Rehab Fuglebækvej 1D DK-2770 KastrupDenmark+45 7025 2522 。
瑟尼妆容清洁液SC-1015说明书

Foaming Facial CleanserSC-1015This clear cleansing gel foams quickly to gently cleanse the skin. Lexquat C provides mild conditioning to leave the skin soft.INGREDIENTS %W/WPROCEDURE:bine phase “A”ingredients and begin heating to 80︒C. Mix with moderate speedpropeller mixing.2.Slowly add “B” ingredients to phase “A” with low speed propeller mixing.3.Begin cooling batch.4.At 40 - 42︒C, add phase “C” to batch.5.Cool to 25︒C and adjust pH to 5.50 –6.0 using phase “D”.PHYSICAL PROPERTIES:pH @ 25︒C = 5.74Viscosity @ 25︒C (Brookfield RVT, Spindle T-C @ 10 rpm) = 14,000cpsSUPPLIERS:1Inolex Chemical Co 2Cognis 3Lipo Chemicals 4Bell Flavors & FragrancesDate: 12/09Ref: 571-072Inolex and its marketing subsidiaries, affiliates, partners and suppliers, disclaim responsibility for results of use of the Materia ls or of any product, method, or apparatus mentioned herein. Nothing stated herein is to be considered a recommendation or inducement of any use, manufacture or sale that may infringe any patents or any other proprietary rights now or hereafter in existence. The Materials are intended to act as a guide foruse at your discretion and risk. We assume no liability in connection with the use, or the utilization of the Materials or the methods or products described therein. Information pertaining to availability, pricing and technical assistance for these products can be obtained from the marketing department, through the nearest sales representative or authorized distributor. Copyright 2002 Inolex Chemical Company. All Rights Reserved.Inolex2101 S. Swanson St. 215 271 0800 office Philadelphia, PA 19148 215 271 2621 fax。
微型浴缸说明书

•Stability to ±0.015 °C•Ranges from -30 °C to 200 °C •Exceptional bath portabilityMicro-Baths can be used anywhere for any type of sensor. The Model 6102 weighs 4.5 kg with the fluid.It’s lighter and smaller than most dry-wells and has a spill-proof lid. Micro-Baths can even be transported with fluid in them.Display accuracy to ±0.25 °C for quick calibrations without a reference thermometer.With a 4.8 cm diameter, 14 cm deep tank, a Micro-Bath can calibrate any type of sensor including short,square, or odd-shaped sensors. The problems of fit and immersion are virtually eliminated by using a fluid medium rather than a dry-block calibrator.Micro-Baths are perfect for liquid-in-glass and bimetal thermometers.All Micro-Baths have RS-232 ports and come with Interface-it software. Also included arecontacts to Calibrate a thermal switch, eight set-point memory storage, ramp-rate adjust and over-tempera-turesafety cutout.Ordering InformationModels7103-256Micro-Bath, 30 °C to 125 °C(includes a transport seal lid and a 2085 test lid), (220 V)7102-256Micro-Bath, -5 °C to 125 °C(includes a transport seal lid and a 2082-P test lid),(220 V)6102-256Micro-Bath, 35 °C to 200 °C(includes a transport seal lid and a 2082-M test lid)(220 V)Options & Accessories2082-P Spare test lid, plastic (7102)2082-M Spare test lid, metal (6102)2085Spare test lid, plastic (7103)20837.6 cm tank expansion adapter for 6102 and 7102(affects stability, uniformity and range at extreme temperatures)5010-L Silicone oil, type 200.05, 1 liter (usable range: -40 °C to 130 °C)5013-L Silicone oil, type 200.20, 1 liter (usable range: 10 °C to 230 °C)9317Carrying case for 71039310Carrying case for 61029311Carrying case for 7102Portability and extreme stability6102, 7102 and 7103 Micro-Baths10 800-404-ATEC (2832)E s t a b l i s h e d 1981Summary specifications 6102, 7102 and 7103Specifications610271027103Range35 °C to 200 °C –5 °C to 125 °C –30 °C to 125 °CAccuracy±0.25 °CStability±0.02 °C at 100 °C (oil 5013)±0.015 °C at –5 °C (oil 5010)±0.03 °C at –25 °C (oil 5010)±0.03 °C at 200 °C (oil 5013)±0.03 °C at 121 °C (oil 5010)±0.05 °C at 125 °C (oil 5010)Uniformity±0.02 °CResolution0.01 °COperating Temperature 5 °C to 45 °CHeating Time25 °C to 200 °C: 40 minutes25 °C to 100 °C: 30 minutes25 °C to 100 °C: 35 minutesCooling Time200 °C to 100 °C: 35 minutes25 °C to 0 °C: 30 minutes25 °C to –20 °C: 45 minutesWell Size 2.5 in dia. x 5.5 in deep (64 x 139 mm)(access opening is 1.9 in [48 mm] in diameter)Size H x W x D26 x 14 x 20 cm31 x 18 x 24 cm34 x 23 x 26 cmWeight 4.5 kg with fluid 6.8 kg with fluid9.8 kg with fluidVolume0.75 L0.75 L 1.0 LPower230 VAC (±10 %), 1.1 A,230 VAC (±10 %), 0.9 A,94–234 VAC (±10 %), 50/60 Hz,switchable, 50/60 Hz, 270 W switchable, 50/60 Hz, 200 W400 WComputer Interface RS-232 included with free Interface-it softwareNIST-Traceable Data at 50 °C, 100 °C, Data at –5 °C, 25 °C, 55°C,Data at –25 °C, 0 °C, 25 °C, 50 °C,Calibration150 °C, and 200 °C90 °C, and 121 °C75 °C, 100 °C, and 125 °CFluke and Hart Scientific have teamed up to solveone of the most common yet neglected problemswhen calibrating process loops: the calibration ofthe temperature sensor itself. Thanks to a newfirmware release, the Fluke 744 calibrator nowsupports Hart Scientific’s Dry-Wells and Micro-Bathsfor complete temperature transmitter calibrations.11。
维萨拉工业测量产品手册说明书

维萨拉工业测量产品手册湿度 | 温度 | 露点 | 二氧化碳 | 沼气 | 油中水分 | 连续监测系统 |溶解气体分析系统 | 过氧化氢 | 压力 | 气象 | 服务支持观测让世界更美好维萨拉的工业测量业务领域产品能够帮助客户了解工艺过程。
我们的产品为客户提供准确可靠的测量数据,帮助客户做出优化工业过程的决策,从而提高过程效率、产品质量、生产力和产量,同时减少能源消耗、浪费和排放。
我们的监测系统还能帮助客户在受监管的环境中运营,以履行监管合规性。
维萨拉工业测量服务于多种类型的运营环境,从半导体工厂和高层建筑,到发电厂和生命科学实验室,对环境条件的可靠监测是实现成功运营的先决条件。
维萨拉的测量产品和系统广泛应用于监测温度、湿度、露点、气压、二氧化碳、汽化过氧化氢、甲烷、油中水、变压器油中溶解气体和液体浓度等参数。
我们的生命周期服务可在测量仪表的整个使用寿命内提供维护。
作为值得信赖的合作伙伴,我们通过在产品和系统生命周期中保证准确的测量数据来支持客户做出可持续的决策。
本产品目录对我们的产品进行整体的介绍,以帮助您选择适合您需求的产品。
如需更多信息,请通过以下方式联系我们:销售热线:400 810 0126电子邮箱:**********************公司网址:扫描二维码,关注维萨拉企业微信3目 录Indigo系列变送器Indigo200系列数据处理单元 (7)Indigo300数据处理单元 (9)Indigo510数据处理单元 (12)Indigo520数据处理单元 (15)用于抽检和校准的手持设备Indigo80手持式显示表头 (18)HMP80系列手持式湿度和温度探头 (21)DMP80系列手持式露点和温度探头 (23)HM70手持式湿度和温度仪 (26)HUMICAP® 手持式湿度温度仪表HM40系列 (29)DM70手持式露点仪 (33)MM70适用于现场检测的手持式油中微量水分和温度测试仪 (36)湿度和温度用于测量相对湿度的维萨拉HUMICAP® 传感器 (38)如何为高湿度应用选择合适的湿度仪表 (40)Insight PC机软件 (44)HMP1墙面式温湿度探头 (46)HMP3一般用途湿度和温度探头 (48)HMP4相对湿度和温度探头 (51)HMP5相对湿度和温度探头 (54)HMP7相对湿度和温度探头 (57)HMP8相对湿度和温度探头 (60)HMP9紧凑型湿度和温度探头 (63)TMP1温度探头 (66)适用于苛刻环境中湿度测量的HMT330系列温湿度变送器 (68)HMT370EX系列本安型温湿度变送器 (78)HMT310温湿度变送器 (84)HUMICAP® 温湿度变送器HMT120和HMT130 (87)适用于高性能暖通空调应用的HMW90系列湿度与温度变送器 (90)HMD60系列湿度和温度变送器 (92)HMD110/112和HMW110/112湿度和温度变送器 (96)适用于楼宇自动化高精度室外测量的HMS110系列温湿度变送器 (99)HMDW80系列温湿度变送器 (101)适用于楼宇自动化应用室外测量的HMS80系列温湿度变送器 (105)HMM100湿度模块 (107)适用于OEM应用的HMM105数字湿度模块 (109)HMM170温湿度模块 (111)INTERCAP® 温湿度探头HMP60 (113)4INTERCAP® 温湿度探头HMP63 (115)HUMICAP® 温湿度探头HMP110 (117)HUMICAP® 温湿度探头HMP113 (120)SHM40结构湿度测量套件 (122)HMK15湿度校准仪 (125)DTR500太阳辐射和雨水防护罩 (127)HMT330MIK气象安装套件 (129)适用于动力汽轮机进气测量的HMT300TMK汽轮机安装组件 (131)露点Vaisala DRYCAP® 传感器用于测量干燥过程中的湿度 (133)DMP5露点和温度探头 (135)DMP6露点探头 (138)DMP7露点和温度探头 (140)DMP8露点和温度探头 (142)DMT340系列露点和温度变送器 (145)适用于高温应用的DMT345和DMT346露点变送器 (151)DMT152露点变送器 (155)DMT143露点变送器 (157)DMT143L露点变送器 (160)用于冷冻干燥机的DMT132露点变送器 (162)DM70用DSS70A便携式采样系统和采样室 (164)DPT146露点和气压变送器 (166)DPT145多参数变送器 (168)二氧化碳适用于苛刻环境的维萨拉CARBOCAP® 测量传感器 (171)GMP343二氧化碳探头 (173)适用于CO2恒温箱的GMP231二氧化碳探头 (176)GMP251二氧化碳探头 (178)GMP252二氧化碳探头 (181)GM70手持式二氧化碳测试仪 (184)适用于苛刻通风要求应用的GMW90系列二氧化碳及温湿度变送器 (187)适用于智能控制通风系统 (DCV) 的GMW80系列二氧化碳、湿度和温度一体变送器 (190)按需控制通风系统中的GMD20系列二氧化碳变送器 (193)GMD110管道安装式二氧化碳变送器 (195)沼气MGP261多气体探头 (197)MGP262多气体探头 (199)油中水用于测量油中微水的维萨拉HUMICAP® 传感器 (201)MMP8油中水分探头 (203)MMT330系列油中微量水分与温度变送器 (205)5MMT310系列油中微量水分与温度变送器 (209)MMT162油中微量水分和温度变送器 (211)连续监测系统维萨拉viewLinc企业版服务器版本5.1 (213)AP10 VaiNet无线接入点 (215)用于连续监测系统的RFL100无线数据记录仪 (218)HMP115温湿度探头 (223)TMP115宽范围温度探头 (225)维萨拉温度与相对湿度数据记录仪系列DL2000 (227)维萨拉通用输入数据记录仪系列DL4000 (229)维萨拉多应用温度数据记录仪DL1016/1416 (231)维萨拉热电偶数据记录仪系列DL1700 (233)维萨拉中端温度、湿度及触点通道数据记录仪 (235)维萨拉vNet以太网供电数据记录仪接口 (238)溶解气体分析OPT100 Optimus™ 溶解气体分析(DGA)监测系统 (240)MHT410变压器油中微量水分、氢气和温度分析仪 (244)过氧化氢用于测量汽化过氧化氢、相对饱和度和相对湿度的维萨拉PEROXCAP® 传感器 (246)用于过氧化氢、湿度和温度测量的HPP270系列探头 (249)压力用于测量压力的维萨拉BAROCAP® 传感器 (253)PTU300气压、湿度和温度一体变送器 (255)适用于专业气象、航空与工业用户的PTB330数字式气压计 (260)气压传递标准PTB330TS (262)PTB210数字气压计 (265)PTB110气压计 (267)将风引起误差降低的SPH10/20静压头 (269)气象Vaisala用于工业应用测量的风和气象传感器技术 (271)风测量装置WA15 (273)WINDCAP® 超声波风传感器WMT700系列 (276)气象变送器WXT530系列 (278)服务支持面向仪表全生命周期服务 (280)67功能•数据处理单元 USB-C 端口支持使用通用 USB 电缆连接到维萨拉Insight PC 软件•数字和图形彩色显示屏(针对模拟型号提供可选的不带显示屏的款式)•IP65 外壳•24 V AC/DC 电源输入•Indigo201:3 个模拟输出(mA 或 V)•Indigo202:RS-485,带有Modbus ® RTU•2 个可配置的继电器维萨拉 Indigo200 系列数据处理单元是一种主机设备,它显示来自维萨拉 Indigo 兼容探头的测量值,同时也可通过模拟信号、Modbus RTU 通信或继电器将这些测量值传输到自动化系统。
智能卫浴方便人们的生活

智能卫浴方便舒适纵享沐浴时光
智能无处不在,卫浴的智能也在逐渐的进入人们的生活,何为卫浴智能化?智能卫浴是不同于一般的卫浴产品,而是把科技,如数码,电控,自动化等应用于五金陶瓷洁具,这样将会把卫浴产品功能提高,提升了卫浴的整体舒适性和便利性,并且,一般的智能产品都会有节能的功能,为世界的环保事业作一份贡献。
在现在的卫浴产品中,坐便器,浴室柜,水龙头,浴缸等都分别不同程度实现了智能化。
随着消费水平的提高,智能化卫浴越来越人性化,有专门为老年人或是儿童设计的保健卫浴产品,智能卫浴行业也越来越渐入佳境。
SAVOIA赛唯雅卫浴就是智能化卫浴中前卫的品牌之一,并且其与国内知名的乐华集团合作,为了在实现卫浴智能化方面更上一层。
据专家指出,一个普通的关不紧的水龙头,一个月会流掉1-6L的水,然而智能水龙头可以省去这些烦恼,自动节水让更多人都点赞,因此智能的卫浴产品不仅仅是卫浴公司为家庭作出贡献,更是为社会作出不可或缺的改变。
因为智能的便利让现代人赞许,因此SAVOIA赛唯雅卫浴根据此和自己的皇家高贵气质优势,创造出不同的智能产品。
如红外线感应的智能水龙头,具有LED灯、除雾镜等多种功能的智能浴室柜或是能实现座便盖加热、温水洗净、暖风干燥、杀菌等多种功能的马桶。
这些都是近几年来比较受欢迎的智能卫浴产品,但是因为智能产品的价格偏高,即使在卫浴产品出现智能化的十几年后,在国内始终难以普及,智能产品代替传统产品的道路还是很漫长的,但是SAVOIA赛唯雅卫浴愿意用其真心去让消费者们感到便利。
不可否认,卫浴出现的智能化方便人们的生活,带给人们更多的生活享受。
SIKO SATSSTK SAT淋浴系统使用说明书

Manuals+— User Manuals Simplified.SIKO SATSSTK SAT Shower System Instruction Manual Home » SIKO » SIKO SATSSTK SAT Shower System Instruction ManualContents1 SIKO SATSSTK SAT ShowerSystem2 Product Information3 Product Usage Instructions4 PRODUCT DIMENSION5 INSTALLATION INSTRUCTION6 PART LIST7 Cleaning Recommendation8 SAFETY INSTRUCTION9 ABOUT COMPANY10 Documents / Resources10.1 ReferencesSIKO SATSSTK SAT Shower SystemProduct InformationThe product is a SATSSTK SATSSTKC, designed for cleaning and maintenance purposes. It is manufactured by SIKO KOUPELNY a.s. The product is made in P.R.C. and imported by SIKO KOUPELNY a.s.Product Usage InstructionsTo ensure proper usage and avoid damage, please follow these instructions:1. When cleaning the fittings and showers, do not use cleaning powders, sponge pads, or microfiber cloths withan abrasive effect.2. Use the specified cleaner dosage and contact time recommended for the product.3. Rinse the surfaces with clean water after using liquid soaps, shampoos, and shower foams to avoid damage.4. If the surfaces are already damaged, they must be exchanged to prevent further deterioration under the effectof cleansers.5. Improper treatment that causes damage will not be covered by the guarantee.6. Install filtration equipment distribution (corner valve filter) as per the guarantee terms.***********************************.swatec.chformoreinformationabouttheproduct.PRODUCT DIMENSIONINSTALLATION INSTRUCTIONPART LIST1-11NDSSTKTERMSET12-13NDSSTK1215NDSSTKPREP16-21NDSSTK2013, 22-24NDSSTK2428NDSIKOBSTPREVLMAT 30-31NDSIKOBSTROZETASET 33NDSSTKJEZDEC34SATHADICE35SATBSRS3636SATBSHS361-11NDSSTKCTERMSET12-13NDSSTK12C15NDSSTKPREP16-21NDSSTK20C13, 22-24NDSSTK24C28NDSIKOBSTPREVLMATC30-31NDSIKOBSTROZETASETC33NDSSTKCJEZDEC34SATBSHPBW35SATBSRS37C36SATBSHS37CCleaning RecommendationTo avoid damage and reclamations, it is necesary to consider certain criteria when cleaning.At the cleaning of the fittings and showers, in principle, it must be pointed out:Only use cleaning material which is explicitly provided for this type of application.Never use cleaning materials, which contain hydrochloric acid, formic acid, chlorine pale lye or acetic acid, as they cause considerable damage.Phosphorus acidic cleaners are only conditionally applicable.Mixing cleaning agents is not permitted, generally.Never use cleaning materials or appliances with an abrasive effect, such as unsuitable clearing powders, sponge pads or micro fibre cloths.The instructions of the cleaning agent manufacturers have to be followed absolutely.Cleaning has to be carried out with a specified cleaner dosage, contact time, object-related and adapted to the needs.The building up of calcifications has to be removed by cleaning regulary.When using spray cleaners, spray first onto a soft cloth or sponge never directly onto the sanitary tapware, as drops could enter openings and gaps and cause damage.After cleaning rinse thoroughly with clean water to remove any cleaner residue.The use of steam cleaners is not permitted. The high temperatures can damage the products.ImportantResidues of liquid soaps, shampoos and shower foams can also cause damage, so rinse with cleanwater after using.The damage of already damaged surfaces will deteriorate under the effect of the cleansers. Components with damaged surfaces must be exchanged, otherwise there could be an injury danger.Damage caused by improper treatment will not be covered by guarantee.Under terms of the guarantee is necessary to install filtration equipment distribution (corner valve filter).SIKO SATSSTK SAT Shower System [pdf] Instruction ManualSATSSTK SAT Shower System, SATSSTK, SAT Shower System, Shower SystemReferencescleaning.atSwiss Aqua Technologies AG - Swiss Aqua TechnologiesManuals+,。
克洛克斯商业用品有限公司克洛克斯浴室用品Toilet Bowl Cleaner 安全数据表说明书

Issuing Date January 5, 2015 Revision Date 8-Dec-2020 Revision Number 4Product identifierProduct Name Clorox Commercial Solutions® Clorox® Toilet Bowl Cleaner with Bleach1Other means of identificationEPA Registration Number 67619-16Document Number US001276Recommended use of the chemical and restrictions on useRecommended use Disinfecting toilet bowl cleaner with bleachUses advised against No information availableDetails of the supplier of the safety data sheetSupplier AddressClorox Professional Products Company1221 BroadwayOakland, CA 94612Phone: 1-510-271-7000Emergency telephone numberEmergency Phone Numbers For Medical Emergencies, call: 1-800-446-1014For Transportation Emergencies, call Chemtrec: 1-800-424-9300ClassificationThis chemical is considered hazardous by the 2012 OSHA Hazard Communicati on Standard (29 CFR 1910.1200).GHS Label elements, including precautionary statementsEmergency OverviewPrecautionary Statements - PreventionWash face, hands and any exposed skin thoroughly after handling.Wear protective gloves, protective clothing, face protection, and eye protection such as safety glasses.Precautionary Statements - ResponseImmediately call a poison center or doctor.If swallowed: Rinse mouth. Do NOT induce vomiting.If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water.Wash contaminated clothing before reuse.If inhaled: Remove person to fresh air and keep comfortable for breathing.Specific treatment (see supplemental first aid instructions on this label).If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Precautionary Statements - StorageStore locked up.Precautionary Statements - DisposalDispose of contents in accordance with all applicable federal, state, and local regulations.Hazards not otherwise classified (HNOC)Although not expected, heart conditions or chronic respiratory problems such as asthma, chronic bronchitis, or obstructive lung disease may be aggravated by exposure to high concentrations of vapor or mist.Unknown Toxicity0.11% of the mixture consists of ingredient(s) of unknown toxicity.Other informationVery toxic to aquatic life.Toxic to aquatic life with long lasting effects.Interactions with Other ChemicalsReacts with other household chemicals such as other toilet bowl cleaners, rust removers, acids, or products containing ammonia to produce hazardous irritating gases, such as chlorine and other chlorinated compounds.First aid measuresGeneral Advice Call a poison control center or doctor immediately for treatmen t advice. Show this safetydata sheet to the doctor in attendance.Eye Contact Hold eye open and rinse slowly and gently with water for 15 - 20 minutes. Remove contactlenses, if present, after the first 5 minutes, then continue rinsing eye. Call a poison controlcenter or doctor for treatment advice.Skin Contact Take off contaminated clothing. Rinse skin immediately with plenty of water for 15-20minutes. Call a poison control center or doctor for treatment advice.Inhalation Move to fresh air. If breathing is affected, call a doctor.Ingestion Call a poison control center or doctor immediately for treatment advice. Have person sip aglassful of water if able to swallow. Do not induce vomiting unless told to do so by a poisoncontrol center or doctor. Do not give anything by mouth to anunconscious person.Protection of First-aiders Avoid contact with skin, eyes, and clothing. Use personal protective equipment as required.Wear personal protective clothing (see section 8).Most important symptoms and effects, both acute and delayedBurning of eyes and skin.Most Important Symptoms andEffectsIndication of any immediate medical attention and special treatment neededNotes to Physician Treat symptomatically. Use of gastric lavage or emesis is contraindicated.Suitable Extinguishing MediaUse extinguishing measures that are appropriate to local circumstances and the surrounding environment.Unsuitable Extinguishing MediaCAUTION: Use of water spray when fighting fire may be inefficient.Specific Hazards Arising from the ChemicalThis product causes burns to eyes, skin, and mucous membranes. Thermal decomposition can release sodium chlorate and irritating gases and vapors.Explosion DataSensitivity to Mechanical Impact None.Sensitivity to Static Discharge None.Protective equipment and precautions for firefightersAs in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.Personal precautions, protective equipment and emergency proceduresPersonal Precautions Avoid contact with eyes, skin, and clothing. Ensure adequate ventilation. Use personalprotective equipment as required. For spills of multiple products, responders should evaluatethe MSDSs of the products for incompatibility with sodium hypochlorite. Breathing protectionshould be worn in enclosed and/or poorly-ventilated areas until hazard assessment iscomplete.Other Information Refer to protective measures listed in Sections 7 and 8.Environmental precautionsEnvironmental Precautions See Section 12 for ecological Information.Methods and material for containment and cleaning upMethods for Containment Prevent further leakage or spillage if safe to do so.Methods for Cleaning Up Absorb and containerize. Wash residual down to sanitary sewer. Contact the sanitarytreatment facility in advance to assure ability to process washed-down material.Precautions for safe handlingHandling Handle in accordance with good industrial hygiene and safety practice. Avoid contact withskin, eyes, and clothing. Do not eat, drink, or smoke when using this product.Conditions for safe storage, including any incompatibilitiesStorage Store in a location inaccessible to children. Tightly close cap between uses.Incompatible Products Other toilet bowl cleaners, rust removers, acids, or products containing ammonia.Control parametersExposure GuidelinesACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value. OSHA PEL: Occupational Safety and Heal th Administration - Permissible Exposure Limits. NIOSH IDLH: Immediately Dangerous to Life or Health.Appropriate engineering controlsEngineering Measures ShowersEyewash stationsVentilation systemsIndividual protection measures, such as personal protective equipmentEye/Face Protection If splashes are likely to occur: Wear safety glasses with side shields (or goggles) or faceshield.Skin and Body Protection Wear rubber or neoprene gloves and protective clothing such as long-sleeved shirt. Respiratory Protection If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approvedrespiratory protection should be worn. Positive-pressure supplied air respirators may berequired for high airborne contaminant concentrations. Respiratory protection must beprovided in accordance with current local regulations.Hygiene Measures Wash hands after direct contact. Do not wear product-contaminated clothing for prolongedperiods. Remove and wash contaminated clothing before re-use. Do not eat, drink, orsmoke when using this product.Physical and Chemical PropertiesPhysical State Viscous liquid Appearance ClearOdorCrisp, green, floral, bleach ColorGreenOdor ThresholdNo information availableProperty Values Remarks/ MethodpH 12.5 - 13.5None known Melting/freezing point No data available None known Boiling point / boiling range No data available None known Flash Point Not flammable None known Evaporation rate No data available None known Flammability (solid, gas) No data availableNone known Flammability Limits in AirUpper flammability limit No data available None known Lower flammability limit No data available None knownVapor pressure No data available None known Vapor density No data available None known Specific Gravity ~1.05 None known Water Solubility Soluble in water None known Solubility in other solvents No data available None known Partition coefficient: n-octanol/water No data available None known Autoignition temperature No data available None known Decomposition temperature No data available None known Kinematic viscosity No data available None known Dynamic viscosity ~1000 cPNone knownExplosive Properties Not explosive Oxidizing Properties No data availableOther Information Softening Point No data available VOC Content (%)No data available Particle SizeNo data available Particle Size DistributionNo data availableReactivityReacts with other household chemicals such as other toilet bowl cleaners, rust removers, acids, or products containing ammonia to produce hazardous irritating gases, such as chlorine and other chlorinated compounds.Chemical stabilityStable under recommended storage conditions. Possibility of Hazardous Reactions None under normal processing.Conditions to avoidNone known based on information supplied.Incompatible materialsOther toilet bowl cleaners, rust removers, acids, or products containing ammonia.Hazardous Decomposition ProductsNone known based on information supplied.Information on likely routes of exposureProduct InformationInhalation Exposure to vapor or mist may irritate respiratory tract and cause coughing. Inhalation ofhigh concentrations may cause pulmonary edema.Eye Contact Corrosive. May cause severe damage to eyes.Skin Contact May cause severe irritation to skin. Prolonged contact may cause burns to skin.Ingestion Ingestion may cause burns to gastrointestinal tract and respiratory tract, nausea, vomiting,and diarrhea.Component InformationInformation on toxicological effectsSymptoms May cause redness and tearing of the eyes. May cause burns to eyes. May causeredness or burns to skin. Inhalation may cause coughing.Delayed and immediate effects as well as chronic effects from short and long-term exposureSensitization No information available.Mutagenic Effects No information available.Carcinogenicity The table below indicates whether each agency has listed any ingredient as a carcinogen.Group 3 - Not Classifiable as to Carcinogenicity in HumansReproductive Toxicity No information available.STOT - single exposure No information available.STOT - repeated exposure No information available.Chronic Toxicity Carcinogenic potential is unknown.Target Organ Effects Respiratory system, eyes, skin, gastrointestinal tract (GI).Aspiration Hazard No information available.Numerical measures of toxicity - Product InformationThe following values are calculated based on chapter 3.1 of the GHS documentNo information available.EcotoxicityVery toxic to aquatic life. Toxic to aquatic life with long lasting effects.Persistence and DegradabilityNo information available.BioaccumulationNo information available.Other adverse effectsNo information available.Disposal methodsDispose of in accordance with all applicable federal, state, and local regulations.Contaminated PackagingDo not reuse empty containers. Dispose of in accordance with all applicable federal, state, and local regulations.DOT Not Regulated per 49 CFR 171.4 (c)(1)IMDG Not Restricted per IMDG Code 2.10.2.7 Marine Pollutant exemptionIATA Not Restricted per IATA Special Provision A197 Environmentally Hazardous SubstanceExemptionChemical InventoriesTSCA All components of this product are either on the TSCA 8(b) Inventory or otherwise ex emptfrom listing.DSL/NDSL All components are on the DSL or NDSL.TSCA - United States Toxic Substances Control Act Section 8(b) InventoryDSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances ListU.S. Federal RegulationsSARA 313Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not contain a ny chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 SARA 311/312 Hazard CategoriesAcute Health Hazard YesChronic Health Hazard NoFire Hazard NoSudden Release of Pressure Hazard NoReactive Hazard NoClean Water ActThis product contains the following substances which are regulated pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.42)CERCLAThis material, as supplied, contains the following substances regulated as a hazardous substance under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) (40 CFR 302)EPA StatementThis chemical is a pesticide product registered by the Environmental Protection Agency and is subject to certain labeling requirements under federal pesticide law. These requirements differ from the classification criteria and hazard information required for safety data sheets and for workplace labels of non-pesticide chemicals. Following is the hazard information as required on the pesticide label:DANGER: CORROSIVE. Causes irreversible eye damage. Causes skin irritation. Prolonged or frequently repeated skin contact may cause allergic reactions in some individuals. Do not get in eyes, on skin, or on clothing. For prolonged use, wear gloves. Wash thoroughly with soap and water after handling. Remove and wash contaminated clothing before reuse. Use only in well-ventilated areas.US State RegulationsCalifornia Proposition 65This product does not contain any Proposition 65 chemicals.U.S. State Right-to-Know RegulationsPrepared By Product Stewardship23 British American Blvd.Latham, NY 121101-800-572-6501Revision Date 8-Dec-2020Revision Note Reference Updated transport. 1108907/50916001.002General DisclaimerThe information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief a t the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal, and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text.End of Safety Data Sheet。
迷你脸部清洁器VisaPure旋转技术清洁器1个清洁刷头1个强度设置BSC111 066倍更好的清洁

VisaPureRotation technologyCleansing1 cleansing brush head1 intensity settingBSC111/066x better cleansingReady in 1 minute*The mini facial cleanser with rotation technology. It's compact. It's easy to use. It'sperfect for your daily skincare. Wherever you are.Better skincareRotation cleansing technology6x better cleansing than hands*. Ready in just 1 minute!Easy to use, easily fits in your skincare routine100% waterproof designRechargeable device for long lasting batteryCleansing has never been easier! 1 minute for better resultsCompatible with all Philips brushesCompact and lightweightCompact and lightweight designGentle to your skinGentle to your skin, tough on impuritiesPerfectly designed for optimal hygieneHighlightsRotation technologyThe rotating motion quickly but gently removes these impurities by sweeping them away,leaving the skin more deeply cleansed.6x better cleansingThanks to the rotation technology and the 17,000 silky soft bristles of the normal cleansing brush you get six times better cleansing results for a soft and radiant skin.Gentle to your skinVisaPure mini facial cleanser is tough onimpurities, but gentle to your skin. Thanks to its silky soft, thin and dense bristles, it ensures a smooth glide while cleansing for absolute skin comfort. VisaPure mini facial cleanser is gentle enough to use twice a day.100% waterproofThis device is 100% waterproof and can be easily used in the shower and cleaned under the tap.RechargeableWhen fully charged, this device has cordless power for 20 uses, equivalent to 10 days when used twice per day.1 minute cleansing programWith the 1 minute recommended cleansing program for effective and superior cleansing,VisaPure mini facial cleanser easily fits in your routine and makes it better!Compatible with all brushesThis device is compatible with all Philips brushes, which are designed to fit your individual skin type and needs.Compact for your convenienceWith its compact and lightweight designVisaPure mini facial cleanser easily fits in your handbag or bathroom shelf. It’s the perfect mini cleanser for your daily skincare routine wherever you are.Designed for optimal hygieneThe silky soft bristle material of all ourVisaPure brush heads is a specially chosen,delicate nylon. This helps to ensure the brush heads are super easy to clean and keep fresh.SpecificationsBenefitsAbsorption: Improves the absorption of your skin care productSkin cleansing: 6x more effective than hand cleansingEase of useCordless: up to 20 uses without charging Battery indicator: Icon indicates battery life 1 Speed settings: Deep cleansing Waterproof: Can be used in the shower Application areasFace and neck: Cheeks, Chin, Fronthead, Neck,NoseItems includedBrush heads: Normal skin brush headInstruction for use: Quick start guide, usermanualPower adapter: 100 - 240 V adapterTechnical specificationsOne way rotationPowerCharging time: 8 hoursPower system: Rechargeable batteryRunning time: 20 uses of 1 minute eachVoltage: 100-240 VServiceWarranty: 2-year limited warranty* *Compared to cleansing by hands. Data on file.© 2020 Koninklijke Philips N.V.All Rights reserved.Specifications are subject to change without notice. Trademarks are the property of Koninklijke Philips N.V. or their respective owners.Issue date 2020‑04‑22 Version: 5.1.112 NC: 8845 400 06220 EAN: 08 71010 38268 73。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Date:Reviewed By/Date:LOWES TEST PROTOCOL FORLWES-01065-NASHOWER CURTAINS (V19)Evaluation Citation/Method Criteria Results RatingSCOPE: The testing procedures outlined in this protocol are designed for Shower Curtains.SUPPLEMENTAL PROTOCOLS* California Proposition 65Safe Drinking Water andToxic Enforcement Actof 1986The sample shall be reviewed against the requirements of California Proposition 65 to determine if additional testing or labeling is required.Note:- When labeling is allowed by the Consent Judgment, and product contains relevant warning label rate as Pass and no actual test is required.- When labeling is NOT allowed by the Consent Judgment, labeling is allowed by the client if it contains a relevant warning label. Rate as Pass. If product does not contain relevant warning label, actual test will be conducted.- Equivalent wordings in warning label are allowed. Warning label shall contain the appropriate name of chemical(s) (if the label contains the chemical names instead of the generic reference to "chemicals"), hazards of the chemical(s) and shall be written in standard format.* Non Regulatory Analytical Testing LWES -GB-PTCL-08443-NA-020All samples shall be reviewed against the requirements of NonRegulatory Analytical Testing supplemental protocol to determine ifadditional testing or labeling is required.Note: Additional cost, sample size & TAT may be required if testing to one or more supplemental protocol is necessary. Please refer to the above referenced supplemental protocol(s) for additional information.LABELING (US)One Time Use ProductsFair Packaging and Labeling Act ORAll Other ProductsUniform Packaging and Labeling RegulationsF.P. & L. Act(16 CFR 500)ORNIST Uniform Laws andRegulations Handbook130For product for the US, Manufacturer, Packer, or Distributor’s Name& Address (City, State & ZIP Code)One Time Use ProductsFair Packaging and Labeling Act ORAll Other ProductsUniform Packaging and LabelingF.P. & L. Act(16 CFR 500)ORNIST Uniform Laws andRegulations HandbookProduct IdentificationLWES-01065-NASHOWER CURTAINS (V19)Evaluation Citation/Method Criteria Results RatingOne Time Use ProductsFair Packaging and Labeling Act ORAll Other ProductsUniform Packaging and Labeling RegulationsF.P. & L. Act(16 CFR 500)ORNIST Uniform Laws andRegulations Handbook130For product for the US, Net quantity of contents shall be expressed interms of weight or mass, measure, numerical count, or combination soas to give accurate information to facilitate consumercomparison.Lowe’s Requirement – Metric Units not required and (“)are acceptable abbreviation for Inch.Country of origin marking 19 CFR 134 For product for the US, shall indicate country of origin legibly,permanently, and in comparable size and close proximity to anymention of country other than country in which the article wasmanufactured or produced. Must be visible at point of purchase. Fiber Content FTC Fiber label must comply with Federal Trade Commission (FTC)RegulationsRN# (Registered Number) FTC Verify presence (Textile fiber products identification act)Care Label 16 CFR 423 Must conform to regulationsLABELING (Product for CANADA)Labeling - packaging - packaging copy or artwork request form may be substitutedConsumer packagingand labelling regulations,C.R.C., c. 417 / ClientrequirementProduct for Canada shall have Manufacturer or distributor’s name &address (City & Postal Code).Placed anywhere except bottom – English or FrenchWhere a prepackaged product is wholly manufactured or produced ina country other than Canada, one of the following formats may beused:-The name and address of a Canadian dealer preceded by the words“imported by” (importé par”) or “imported for” (“importé pour”); or-The statement of geographic origin located immediately adjacent tothe name and address of a Canadian dealer; or-The name and address of the dealer outside CanadaClient requirement = do not evaluate font sizeLabeling - packaging - packaging copy or artwork request form may be substitutedConsumer packagingand labelling regulations,C.R.C., c. 417 / ClientrequirementProduct Net QuantityDeclaration must be in English and French, metric units, on PDP, boldClient requirement = do not evaluate font sizeLWES-01065-NASHOWER CURTAINS (V19)Evaluation Citation/Method Criteria Results RatingLabeling - packaging - packaging copy or artwork request form may be substitutedConsumer packagingand labelling regulations,C.R.C., c. 417 / ClientrequirementProduct identification shall be English and French, on PDP and in boldClient requirement = do not evaluate font sizeLabeling – packaging Consumer packagingand labeling regulations,C.R.C., c. 417 section 6 For product for Canada, all mandatory labeling information must be shown in both French and English languages. The type of mandatory labeling that is required includes, but is not limited to, any written statement or warning, product identity, net content and ingredient declarations. The names and address of the manufacturer and country of origin labeling requirements may be presented in either French or English. Other supplemental label information that is considered to be non-mandatory (e.g. directions for use) also does not have to appear in a bilingual manner. However, manufacturers are encouraged to include such information in a bilingual format if plausible.Country of origin marking Canada Customs Tariff,Marking of ImportedGoods Regulations,SOR-94-10 / Marking ofImported GoodsMemorandum D11-3-1 a) Imported goods shall indicate country of origin.b) Must be legible and sufficiently permanent to remain on the goods until it reaches the purchaser.c) For goods from NAFTA countries, the language may be English, French or Spanish.d) For goods from non-NAFTA countries, language may be English or French and marking should appear on individual articles.e) If the packaging conceals the Country of Origin mark, then the packaging must also be marked.f) There is a provision to mark only the container providing that certain conditions are met, such that the ultimate purchaser will see the marked container.**Fiber Content Label Canadian TextileLabeling ActR.S., c. T-10(For Indoor Items Only) Must be bilingual and must contain the generic name and amount of fiber expressed in %.Must be visible at point of purchase (can be sewn on, on sticker label/hangtag, on package or imprint directly on the article). Note: Take exhibit photo and attach with the reportLabeling of Pre-PackagedConsumer Textile Articles (if Applicable) Visual Per Section 21 of the Textile Labeling and Advertising Regulations,C.R.C., c. 1551, if the textile article is sold in a wrapper, package orcontainer and the fiber content label is clearly visible to the consumer,no further labeling is required. If the label is not visible, theinformation to be shown on the label must be repeated on the wrapper,package or container in the prescribed manner.Note: Take exhibit photo and attach with the reportLWES-01065-NASHOWER CURTAINS (V19)Evaluation Citation/Method Criteria Results Rating Care Label (If claimed) Visual If Canadian care symbols are used, the care labels must bepermanently attached to the textile article.Canadian Care Symbols must be presented in accordance with theNational Standard of Canada, Care Labeling of Textiles, andCAN/CGSB-86.1-2003 and must be accurate based on the criteria inthis standard.Note: Take exhibit photo and attach with the reportCA No. or Dealer Identity Visual The CA number of the Canadian dealer or the name and full postaladdress under which the dealer normally carries out his business mustbe present on the fiber content label per Sections 11 and 12 of theTextile Labeling and Advertising Regulations.Note: Take exhibit photo and attach with the reportLABELING (ALL)Claim verification - Level 2 Claim verification Examine the retail packaging (or submitted artwork).Record each objective (factual) claim which can be substantiated bythe testing within this protocol and rate accordingly.Any net quantity/dimensional claims evaluated in other sections of thisprotocol need not be recorded.Record all other objective (factual) and subjective (opinion) claims as"NT" for Not Tested and report as data (also include in the remarkssection of the Executive Summary).Modification = claim(s) not verified / tested report as data.Use Labeling Visual Use/care instructions that are clear and understandable shall beprovided.ANALYTICAL*Mildew Resistance (Qualitative) AATCC 30 [If claimed]No growth on 6 x 6 inch swatchPHYSICAL CHARACTERISTICSOverall Dimensions Standard Measure Report overall dimensions; shall meet label claims (if applicable).Report in primary units as claimed. ( -5 / +5%)Weight (Gms.) Standard Measure Report overall weight; shall meet label claims(If applicable) (-10 / +10%)LWES-01065-NASHOWER CURTAINS (V19)Evaluation Citation/Method Criteria Results RatingFiber Analysis: Blends AATCC 20A/20A Blends : 3% toleranceSingle Fiber : No toleranceCONSTRUCTION & WORKMANSHIPDefects Visual •No Major Defects, Shall demonstrate good, even construction,with no sharp edges, sharp points or discoloration.•Shall have no components missing. Shall Function as intended.PERFORMANCE*Canadian Flammability - Textile Products Textile FlammabilityRegulations /CAN/CGSB-4.2No.27.5:2008Time of flame spread shall be(a) greater than 3.5 seconds where the product does not have a raisedfiber surface, or(b) time of flame spread shall be greater than 4.0 seconds, where theproduct has a raised fiber surface and exhibits ignition or fusion of thebase fibers* Flammability – US ASTM D1230-10 Must comply* Flammability of Vinyl Film - US 16 CFR 1611 Meets RequirementFunctionality Visual Shall function as intended as received* Resistance to corrosion - only for indoor metal components ASTM B117 modified Metal for use in damp, or wet locations (ie. bathroom) shall withstand24 hours in 1% salt fog with no failure of any of the following:•Ferrous rust corrosion (red rust)•Loss of functionInclude before and after photos of any corrosion areas in report. (Useanother sample for “before” photo. If none available, cover photo isacceptable.)LWES-01065-NASHOWER CURTAINS (V19)Evaluation Citation/Method Criteria Results Rating*Dimensional changes of garments after home laundering(After 3HL If Applicable) AATCC 150 [If claimed]Woven –General Fabrics: -3% x -3%Stretch Fabrics (with spandex): -4% x -4%Corduroy, Velvet, Terry, Flannel, Jacquard, Basket, Pique: -5% x -5%Growth: +1% maximumKnit –General Fabrics: -5% x -5%Stretch Fabrics (With Spandex): -6% x -6%Fleece/ Sherpa / French Terry: -6% x -6%Rib/ /Pique: -7% x -7%Thermal: -8 % x -8%Growth: +3% maximum*Appearance after care (3 HL) Per Care instructions [If claimed]List all observations affecting the end productperformance/appearance. For laminated products: no bubbling,puckering, crack marks or blisters, or face fabric pilling.Color Change: ModerateSelf Staining: SlightSeam Appearance/Wrinkling: Fairly smooth but non-pressedappearanceFrosting: Moderate DifferencePilling: Moderate PillingCOLORFASTNESSCrocking AATCC8 or 116 Dry: Grade 4 minimumWet: Grade 3 minimumEXCEPTIONS: Dark Colors (Hunter Green, Dark Red, Burgundy, Black, Navy) regardless of Dyestuffs/Fabrication Dry: Grade 3 minimumWet: Grade 2 minimum* Actual Laundering(After 1HL, 3 HL as per care label) AATCC 150 Modified [If claimed]Color change: Grade 4 minimum after 3 HLStaining: Grade 3 minimum after 1HLSelf- staining: Grade 4.5 minimum after 3 HL(Modification = Adding Multifiber to Specimen)LWES-01065-NASHOWER CURTAINS (V19)Evaluation Citation/Method Criteria Results Rating* Quick methods for colorfastness to chlorine bleach(If care label is present) AATCC/ASTM TS-001 Grade 4 Minimum(If "Do not bleach" claim is made - Do not perform bleach tests andmark as "N/A" per label claim of "Do Not Bleach on product")* Quick methods for colorfastness to non chlorine bleach(If care label is present) AATCC/ASTM TS-001 Grade 4 Minimum(If "Do not bleach" claim is made - Do not perform bleach tests andmark as "N/A" per label claim of "Do Not Bleach on product")Key:* Additional Charge For This TestYellow highlighted tests are Canadian tests to be conducted when distributing in Canada Blue highlighted tests are US tests to be conducted when distributing in the USResults Key: Rating Key:M Meets NM Does Not Meet Good Good Unsat. UnsatisfactoryNA Not Applicable NT Not Tested C/A Conditionally Approved -- Not RatedC Claimed R RecordedNo. Of Samples Required For Complete Testing: 3 sq. yd (fabric) +2 garmentsNo. Of (Fully Packed) Cartons For Transit Testing: 1 Creation Date: ARPIL 16, 2010 No. Of Working Days For Complete Testing: 7 Editorial Revision Date: JULY 31, 2013 No. Of Working Days for Mildew Resistance 20ITS Review Date: January 22, 2013SGS Review Date: January 21, 2013。