手机数据线可靠性测试标准
手机数据线测试检验标准(Data cable Inspection Standard)

手机数据线检测标准Data cable Inspection Standard版本记录Version Records本文件属于公司秘密信息,请您恪守保密义务,勿向第三人透露。
谢谢合作。
This file is confidential. Recipient(s) is(are) obligated to maintain secrecy and is(are) not permitted to disclose the contents of this file to others. Thank you.1、目的Purpose为确保数据线的生产、检验工作有序进行,为过程质量控制、例行检验、最终成品检验和确认检验提供依据。
This standard is the data cable quality acceptance criterion, to ensure the data cable design and produce meet the quality requirements, make sure product quality, provide the judgment standard for the inspection;2、适用范围 S cope本标准适用本公司手机产品的各种数据线质量检验。
The standard will be applied to data cable’s quality evaluation and sampling inspection for all XXX products ;3、规范性引用文件Referred files手机可靠性测试标准;reliability test standard手机外观检验标准;handset appearance inspection standard4、检验工具 E quipment游标卡尺、硬度计、投影测试机、振动测试仪、拉力计、压力计、扭曲测试仪、盐雾机、摇摆测试机、自由跌落测试机、拔插测试机、高低温箱Vernier Caliper, Hardness Meter, Projective Tester, Vibration Tester, Tension Meter, Pressure Meter, Torque Meter, Salt Tester, Swing Tester, Free Fall Tester, Insertion and Draw Tester, Temperature Chamber.5、基本要求Requirement5.1 工作条件Working condition工作温度范围Working temperature range :-20℃~65℃相对湿度Humidity:5%~90%大气压力Atmospheric pressure:70 KPa~106 KPa存储温度Store Temperature: -40℃~70℃5.2 外观要求Appearance requirement数据线表面应平整无划痕,外观无损伤、碎裂痕迹、镀涂层剥落、外露金属无锈;塑料制品不应有起泡、断裂、变形、烫伤、污溃;卡簧安装方向正确。
数据线检验标准

判定MIN MIN MIN MINMIN MIN MIN MAJ MAJMAJ MAJ MAJ MAJ(二)、外觀卡尺判定标准(一)、包裝1.拿取时要戴手套,静电环.按承认书QC管制尺寸检验,或对样品.目视1.来料颜色、形状是否与样品一致.目视1.与手机及电脑连接实配,并用1Kg力度做拉拔测试,要求数据线无松动无接触不良。
(四)﹑尺寸成品机台版 次一﹑作业內容品质检验人員抽样计划依照MIL-STD-105E, 正常检验(Normal Inspection), Level II, 单次抽样。
如客戶有特殊要求﹐以客戶提供之抽样水准抽样。
品质检验允收水准(AQL): MA=0.1,MI=1.0。
抽样计划采用『分批检查, 分批验退』的方式。
二﹑缺点分类致命缺点 (Critical Defect, CR) 指由经验和判断表明产品对人体有害的产品缺陷。
2.检測时注意动作轻柔﹐避免碰撞﹑摔落。
不可叠放﹑竖放﹐以防損坏。
严重缺点 (Major Defect, MAJ)指影响产品正常使用功能,降低产品可靠性或严重影响产品外观的缺陷. 轻微缺点 (Minor Defect, MIN) 偏离限定标准,但不影响产品正常使用功能或外观缺陷不太明显的缺陷。
1.來料外箱无厂商名称,料号,品名规格之标示并确认來料是否为禁用料.五﹑注意事項三.检验条件位置: 产品置放于检验者正前面, 垂直于检验者。
目视時間: 10秒钟内确认缺陷。
目视距离:肉眼与被测物距离30cm至45cm. 深圳万事通通信技术发展有限公司MSTIQC-07-024第3页共3页1.0文 件 编 号页 次目视2.來料包装不合理导致材料受损或其它不良现象(需有透明袋单独包装).目视3.同一批量中,混有两种或以上不同规格之物料.目视 目视角度:与被测物成30度至45度角范围内 工作场所灯光: 60W,距离检测者50cm.四﹑检验步骤检验项目检验方法和工具目视2.表面不可有污点、毛刺、气泡、凹凸点、脱漆、划伤、压痕等不良现象.目视1.是否可将电脑与手机连接,且可以彼此储存、读写、删除文件及充电.1.拆开接口观察内部焊接方式及材质是否与样品一致.2.有无锡渣、锡珠、虚焊、假焊、断铜丝、各元件及结构是否与样品一致等不良现象.(六)﹑试装3.实配后观察USB接口及手机接口PIN是否有下陷等现象.成品机台2.与机台不可有干涉,间隙,多出等不良现象.成品机台(三)、工艺刀片、目视刀片、目视(五)﹑性能2.绕线确认接口处有无焊接不良现象.。
USB-3.0--A-TO--C-可靠性测试规范

30
环保要求
本技术要求数据线所有组成材料符合ROHS要求,Reach要求.
外背jacket无断裂;
连接器与线缆无分离;
芯线端点无脱离连接器;
电气性能正常;
导通阻抗符合规格要求,并记录实际值
EIA 364-41
6
滚筒跌落
跌落高度1米,跌落次数150次,每50检查一次,跌落速度参考值10-12次/分次(以跌落在滚筒铁板中心位置为准)
测试完成线缆无损坏,松脱;
连接器可以无明显尺寸变化;
修订履历
版本
修订内容
日期
修/制订者
审核
批准
A/0
新制订
2017-03-03
Peter
Mils
YANG
可靠性测试规范:
Test condition
Temperature:15℃ to 35℃
Air pressure :86 to106 kPa
Relativehumidity:25% to 85%
NO
Test description
29
阻燃要求
VW-1(北美),满足IEC60332或GB/T18380电缆在火焰条件下的燃烧试验标准(欧洲、国内)。
参考标准:IEC60950/EN60950/UL60950/GB4943、IEC60332/GB/T18380、UL1581
满足IEC60332或GB/T18380电缆在火焰条件下的燃烧试验标准(欧洲、国内)。
Micro USB插拔耐久测试前后:拔出力大于等于8N,小于等于20N
EIA364-13
usb数据线检验标准

usb数据线检验标准USB数据线检验标准。
USB数据线作为连接电子设备和充电设备的重要工具,其质量的好坏直接影响着设备的充电速度和数据传输效率。
因此,制定USB数据线检验标准,对于保障用户权益,提高产品质量具有重要意义。
首先,USB数据线的外观应当符合标准规定,线材应该柔软而有弹性,外部不应该有明显的破损或者变形。
连接头部分应该与线材连接紧密,不应该出现松动现象。
其次,USB数据线的传输性能也是检验的重点之一。
传输性能主要包括数据传输速度和充电速度。
数据传输速度应该符合USB协议规定的标准,充电速度也应该在合理范围内,不能出现充电缓慢或者充电不稳定的情况。
另外,USB数据线的耐用性也是需要检验的重点之一。
耐用性主要体现在插拔次数和弯曲次数上,合格的USB数据线应该能够经受多次的插拔和弯曲而不影响其正常使用。
除了上述几点之外,USB数据线的安全性也是需要检验的重点。
合格的USB 数据线应该符合国家相关的安全标准,不应该出现漏电、过热等安全隐患。
另外,USB数据线的防护性也是需要考虑的因素,合格的USB数据线应该具有一定的防护功能,能够防止外部环境对线材的损坏。
总的来说,USB数据线的检验标准应该包括外观检验、传输性能检验、耐用性检验、安全性检验和防护性检验等内容。
只有通过严格的检验标准,才能够保障用户的权益,提高产品的质量,推动整个行业的健康发展。
在实际生产中,制定严格的USB数据线检验标准并不是一件容易的事情,需要相关部门和企业的共同努力。
一方面,相关部门应该加强对USB数据线质量的监督和检验,建立健全的检验体系,加大对违规产品的处罚力度;另一方面,企业应该自觉遵守USB数据线的相关标准,加强内部质量管理,提高产品质量。
总之,USB数据线作为电子产品中不可或缺的配件,其质量的好坏直接关系到用户的体验和设备的使用寿命。
制定严格的USB数据线检验标准,对于保障用户权益,提高产品质量具有重要意义。
希望通过全社会的共同努力,能够建立起一套严格的USB数据线检验标准体系,为消费者提供更加优质的产品。
手机数据线检验标准

数据线组件文件编号:HBS—PZ ---WI—015更改记录目录1.0............................................................................................................................................................................. 目的2.0............................................................................................................................................................................. 范围3.0............................................................................................................................................................................. 抽样计划4.0............................................................................................................................................................................. 定义4.1 ...................................................................................................................................................................... 检验条件4.2 ...................................................................................................................................................................... 抽样标准5.0 .......................................................................................................................................................................... 术语和定义5.1 ...................................................................................................................................................................... 缺陷等级5.2 .................................................................................................................................................... 数据线不良缺陷定义6.0............................................................................................................................................................................. 检验内容6.1..................................................................................................................................................... 外观不良判定标准6.2............................................................................................................................................................. 尺寸判定标准7.0....................................................................................................................................................... 可靠性试验及判定标准8.0................................................................................................................................................................... 周期性测试要求9.0 .......................................................................................................................................................................... 包装要求10.0 ...................................................................................................................................................................... 出货附带报告手机数据线检验标准1.0目的本标准明确了深圳市华邦盛电子有限公司手机数据线的质量检验标准,确保产品质量达到客户要求。
PR-QA-0045手机数据线类可靠度测试规范

1.目的
为确认和监督产品各阶段的可靠度符合要求;使ORT作业有所依据,有计划进行从而确保产品的品质。
2.适用范围
适用于本公司开发阶段/试产/量产等阶段产品之相应测验。
3.名词定义
ORT(On Going Reliability Test):产品可靠度测试。
4.职责权限
4.1 研发和工程单位负责对新产品的开发,设计,改良。
4.2 品管在生产制令批中/外购进料批中取样送至实验室。
4.3 实验室执行产品ORT验证。
5.作业内容
5.1检测频率:开发验证/试产/量产/例行1个月。
5.2送测单位依测验需求填写测验申请单与待检测样品一起送至实验室。
5.3 实验室依ORT测试项目及测试条件执行ORT测试。
5.4 测验结束后实验室出具检测报告,测试样品由送测单位取回,测试结案。
5.5 当实验不合格时,依《不合格品控制程序》处理。
5.6客户有特殊要求的依客户要求执行测验。
5.7产品测试项目,条件及判定如下:
6.支持文件
6.1《不合格品控制程序》 COP-830-01
7.记录
7.1《测验申请单》 QR-760-08 7.2《检测报告》 QR-824-08。
华为数据线测试标准

测试数量、频率
5pcs/月 5pcs/月 5pcs/月 5pcs/月 5pcs/月 5pcs/月
5pcs/月
5pcs/月 5pcs/月
5pcs/月
复插拔5次,记录最大拔出力并计算平均值。
类型 次数
USB A 1500
接口插入力及拔出力检测 MiniUSB 5000
MicroUSB 10000
要求:试验后样品连接插头从插座中完全拔出的力量USB-A拔出力不小
于8N,MiniUSB拔出力不小于3N,MicroUSB拔出力不小于8N。样品能
正常充电及上传下载数据。
线体抗拉测试5Kgf,1分源自静拉基本功能1.550mA充电40分钟; 2.文件传输(文件大小5M、反复3次)
接触可靠性测试
上下、左右、前后、用力扭动
反向插拔防呆设计
反向不可插入 试验方法:将插座与插头分别固定在试验台上进行反复试验,插拔频
率不超过200次/h,插拔次数如下表,试验后以12.5mm/min的速度重
测试项目 插拔耐久性试验 线材弯折测试
I类标准
I/O插拔手机5000次. 充电线USB口与充电头插拔配合3000次,与电脑串口插拔2000次. 试验方法:样品负重500g,正负60度,总共120度,以20次/分钟的速 度弯折3000次(一次来回计一次)。 要求:芯线不可有短路现象,样品能正常充电及上传下载数据
高温贮存试验 低温贮存试验 盐雾试验
试验方法:样品放置于70℃±2℃的恒温箱中,放置16h。恢复2h后测 试。 要求:试验后样品无应出现起泡、变形、变色、功能丧失,数据线能 正常通信 试验方法:样品放置于-40℃±2℃的恒温箱中,放置16h。恢复2h后测 试。 要求:试验后样品无应出现起泡、变形、变色、功能丧失,数据线能 正常通信 试验方法:样品在35℃±2℃的密闭环境中,湿度>85%,PH值在6.57.2范围内,用5%±0.1%的Nacl溶液连续喷雾(铁壳48h,PIN针 72h)后,将样品用清水冲洗干净后在常温环境内放置2h后检查产品的 外观。 要求:样品插头不得有生锈、氧化现象。
手机数据线质量检验规范

好好学习社区
更多优惠资料下载:
德信诚培训网
手机数据线质量检验规范
(ISO9001-2015)
1、常规标准要求
序
号 检验项目 标准要求
缺陷类别
检验工具
B 类
C 类 1 型号 型号,线材型号等对比样品、规格书是否一致 ● 目视 2 标识 数据线上贴纸、插头朝向标识是否与样品一致 ● 3
胶体
起泡、缩水、起丝、脏污,严重划伤和异色点
● 目视 4 毛刺批锋 不能有刮手的毛刺和批锋 ● 酒精、擦布
5 破损 线材、胶体不能破损、缺角,露线材芯现象 ●
6 锈蚀 外露金属部分不允许有锈蚀 ● 目视
7 变形 Pin 针不能有变形,翘起现象
● 目视 8
开裂
在扣位和壳体结合处,扳扣位或壳体结合处,不
能松动和开裂
● 目视 9 挂钩弹性
挂钩弹性良好,装卸方便,插上插头至少能承受200g 拉力(约大于1台手机重量),5s 不松脱
●
工装手机
2、尺寸
序号 测量项目
测量方法
接受标准
测量工具 抽样数量 1
尺寸超差 用卡尺或投影仪测量产品的关键、重要尺寸及装配尺寸
尺寸在工程设
计规格内 卡尺
5pcs/lot
2 配合不良
两端连接头与对应的手机和电
脑不能出现不易插入或难取出
配合松紧适度
电脑 2pcs/lot
3、可靠性检验
3.1 IQC 常规可靠性检验
序
号 检验项目 检验内容方法及条件
接受标准
检验工具 抽样数量 1
接触阻抗 将数据线与其配套插头配合后
测量其阻抗
每PIN 引脚阻
抗小于规格书
要求
万用表
5pcs/lot。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
德信诚培训网
更多免费资料下载请进: 好好学习社区 手机数据线可靠性测试标准
1、范围
本标准规定了手机数据线需要满足的可靠性能要求,以及其试验方法及质量评定标准。
本标准适用于公司在新产品开发及生产和出货过程中数据线样品的确认、 周期性质量监控、出货可靠性能检测标准。
2.检测项目与要求
2.1 常规性能指标
2.1.1 摇摆试验
a)测试区域:数据线插头网尾处。
b)测试条件:摇摆试验机(要求:当导线开路时能够自动停止;能够数显自动计数) 。
c)测试要求:
1)对要进行测试部分引出处的母体(插头)固定,使引出线垂直朝下。
2)负载100g ,摆动角度±60°、25次(来回)/分钟,摇摆半径800mm ,摆动1000次;
d )测试结果:试验完后对线体进行导通性测试,不应出现开路、短路等电性能不良。