施耐德(优力)空调(UG40面板)使用讲解-文档资料

合集下载

施耐德电气 Easy UPS 3S 10-40 kVA 操作说明书

施耐德电气 Easy UPS 3S 10-40 kVA 操作说明书
维护 .............................................................................................................40
部件更换 ..................................................................................................40 确定是否需要更换部件 ........................................................................40
带内部电池和模块电池柜的 UPS 的推荐设置 ........................................34 设置生命周期监控..................................................................................... 36 设置......................................................................................................... 37
目录
10-40 kVA
重要安全说明- 请妥善保存这些说明 ......................................................5
电磁兼容性.................................................................................................6 安全注意事项 .............................................................................................6

施耐德空调UG40通讯协议

施耐德空调UG40通讯协议

UG40----NEW LEONARDO: DIGITAL VARIABLES (COILS)variable address description variabletypeMODBUS Database(e.g. address -> bit nr.)unit 1 unit 2 unit 3 unit n0 Notused … 1 201 401 (n-1)*200+11 System On (Fan) R2 202 402 (n-1)*200+22 Compressor1 R 3 203 403 (n-1)*200+3 3 Compressor2 R 4 204 404 (n-1)*200+4 4 Compressor3 R 5 205 405 (n-1)*200+5 5 Compressor4 R 6 206 406 (n-1)*200+66 El. Heater 1 R7 207 407 (n-1)*200+77 El. Heater 2 R8 208 408 (n-1)*200+88 NotUsed R9 209 409 (n-1)*200+99 Hot gas ON R10 210 410 (n-1)*200+1010 Dehumidification R11 211 411 (n-1)*200+1111 Humidification R12 212 412 (n-1)*200+1212 EmergencyWorking R13 213 413 (n-1)*200+1313 Not used…14 214 414 (n-1)*200+1414 Not used…15 215 415 (n-1)*200+1515 Not used…16 216 416 (n-1)*200+1616 Not used…17 217 417 (n-1)*200+1717 Not used…18 218 418 (n-1)*200+1818 Not used…19 219 419 (n-1)*200+1919 Not used…20 220 420 (n-1)*200+2020 Wrong Password Alarm R21 221 421 (n-1)*200+2121 High Room Temperature Alarm R22 222 422 (n-1)*200+2222 Low Room Temperature Alarm R23 223 423 (n-1)*200+2323 High Room Humidity Alarm R24 224 424 (n-1)*200+2424 Low Room Humidity Alarm R25 225 425 (n-1)*200+2525 Room Temp. And Humidity Limits by ExternalSensorsR26 226 426 (n-1)*200+2626 Clogged Filter Alarm R27 227 427 (n-1)*200+2727 FloodingAlarm R28 228 428 (n-1)*200+2828 Loss of Air Flow Alarm R29 229 429 (n-1)*200+2929 Heater Overheating Alarm R30 230 430 (n-1)*200+3030 Circuit 1 High Pressure Alarm R31 231 431 (n-1)*200+3131 Circuit 2 High Pressure Alarm R32 232 432 (n-1)*200+3232 Circuit 1 Low Pressure Alarm R33 233 433 (n-1)*200+3333 Circuit 2 Low Pressure Alarm R34 234 434 (n-1)*200+3434 Circuit 1 Electronic Valve Failure R35 235 435 (n-1)*200+3535 Circuit 2 Electronic Valve Failure R36 236 436 (n-1)*200+3636 Wrong Phase Sequence Alarm R37 237 437 (n-1)*200+3737 Smoke-FireAlarm R38 238 438 (n-1)*200+3838 Interrupted LAN Alarm R39 239 439 (n-1)*200+3939 Humidifier: High Current Alarm R40 240 440 (n-1)*200+4040 Humidifier: Power Loss Alarm R41 241 441 (n-1)*200+4141 Humidifier: Water Loss Alarm R42 242 442 (n-1)*200+4242 CW Temperature too High for Dehumidification R43 243 443 (n-1)*200+4343 CW Valve Failure or Water Flow too Low R44 244 444 (n-1)*200+4444 Loss of Water Flow Alarm R45 245 445 (n-1)*200+4545 High Chilled Water Temperature Alarm R46 246 446 (n-1)*200+4646 Room Air Sensor Failed/Disconnected R47 247 447 (n-1)*200+4747 Hot Water Temp. Sensor Failed/Disconnected R48 248 448 (n-1)*200+4848 Chilled Water Temp. Sensor Failed/Disconnected R49 249 449 (n-1)*200+4949 Outdoor Temperature Sensor Failed/Disconnected R50 250 450 (n-1)*200+5050 Delivery Air Temp. Sensor Failed/Disconnected R51 251 451 (n-1)*200+5151 Room Humidity Sensor Failed/Disconnected R52 252 452 (n-1)*200+52R53 253 453 (n-1)*200+5352 Chilled Water Outlet Temp.SensorFailed/Disconnected53 Compressor 1: hour counter threshold Alarm R54 254 454 (n-1)*200+5454 Compressor 2: hour counter threshold Alarm R55 255 455 (n-1)*200+5555 Compressor 3: hour counter threshold Alarm R56 256 456 (n-1)*200+5656 Compressor 4: hour counter threshold Alarm R57 257 457 (n-1)*200+5757 Air filter: hour counter threshold Alarm R58 258 458 (n-1)*200+5858 Heater 1: hour counter threshold Alarm R59 259 459 (n-1)*200+5959 Heater 2: hour counter threshold Alarm R60 260 460 (n-1)*200+6060 Humidifier: hour counter threshold Alarm R61 261 461 (n-1)*200+6161 Air conditioning unit: hour counter threshold Alarm R62 262 462 (n-1)*200+6262 Alarm by Digital Input 2 R63 263 463 (n-1)*200+6363 Alarm by Digital Input 4 R64 264 464 (n-1)*200+6464 Alarm by Digital Input 6 R65 265 465 (n-1)*200+6565 Humidifier General Alarm R66 266 466 (n-1)*200+6666 Unit on Alarm R67 267 467 (n-1)*200+6767 Unit on Rotation Alarm R68 268 468 (n-1)*200+6868 Unit on Alarm Type A R69 269 469 (n-1)*200+6969 Unit on Alarm Type B R70 270 470 (n-1)*200+7070 Unit on Alarm Type C R71 271 471 (n-1)*200+7171 DX/CW Switch on TC Units R/W 72 272 472 (n-1)*200+72Switch R/W 73 273 473 (n-1)*200+7372 Summer/Winter73 Not used…74 274 474 (n-1)*200+7474 Not used…75 275 475 (n-1)*200+7575 Unit ON/OFF Switch R/W76 276 476 (n-1)*200+7676 Buzzer and Alarm Unit Reset R/W77 277 477 (n-1)*200+7777 Filter Run Hours Reset R/W78 278 478 (n-1)*200+7878 Compressor 1 Run Hours Reset R/W79 279 479 (n-1)*200+7979 Compressor 2 Run Hours Reset R/W80 280 480 (n-1)*200+8080 Compressor 3 Run Hours Reset R/W81 281 481 (n-1)*200+8181 Compressor 4 Run Hours Reset R/W82 282 482 (n-1)*200+8282 Compressor 1 Starting Reset R/W83 283 483 (n-1)*200+8383 Compressor 2 Starting Reset R/W84 284 484 (n-1)*200+8484 Compressor 3 Starting Reset R/W85 285 485 (n-1)*200+8585 Compressor 4 Starting Reset R/W86 286 486 (n-1)*200+8686 Heater 1 Run Hours Reset R/W87 287 487 (n-1)*200+8787 Heater 2 Run Hours Reset R/W88 288 488 (n-1)*200+8888 Heater 1 Starting Reset R/W89 289 489 (n-1)*200+8989 Heater 2 Starting Reset R/W90 290 490 (n-1)*200+9090 Humidifier Run Hours Reset R/W91 291 491 (n-1)*200+9191 Humidifier Starting Reset R/W92 292 492 (n-1)*200+9292 Unit Run Hours Reset R/W93 293 493 (n-1)*200+9393 Not used…94 294 494 (n-1)*200+9494 Not used…95 295 495 (n-1)*200+9595 Setback Mode (Sleep Mode) R/W96 296 496 (n-1)*200+9696 Sleep Mode Test R/W97 297 497 (n-1)*200+9797 Local/Mean Usage of Values R/W98 298 498 (n-1)*200+9898 No. of Stand-by Units R 99 299 499 (n-1)*200+99used … 100 300 500 (n-1)*200+100 99 NotOnly for LAN Unit Number 1:100 Unit 2 on Rotation Alarm R101 301 501 (n-1)*200+101 101 Unit 3 on Rotation Alarm R102 302 502 (n-1)*200+102 102 Unit 4 on Rotation Alarm R103 303 503 (n-1)*200+103 103 Unit 5 on Rotation Alarm R104 304 504 (n-1)*200+104 104 Unit 6 on Rotation Alarm R105 305 505 (n-1)*200+105 105 Unit 7 on Rotation Alarm R106 306 506 (n-1)*200+106 106 Unit 8 on Rotation Alarm R107 307 507 (n-1)*200+107 107 Unit 9 on Rotation Alarm R108 308 508 (n-1)*200+108 108 Unit 10 on Rotation Alarm R109 309 509 (n-1)*200+109NEW LEONARDO: ANALOG VARIABLES (HOLDING or INPUT REGISTERS)(all values x 10)variable address description m.u.variabletypeMODBUS Database(e.g. address -> bit nr.)unit 1unit 2 unit 3 unit n0 Notused - - 1 257 513 (n-1)*256+1 1 RoomTemperature °C R 2 258 514 (n-1)*256+2 2 OutdoorTemperature °C R 3 259 515 (n-1)*256+33 Delivery Air Temperature °C R4 260 516 (n-1)*256+44 Chilled Water Temperature °C R5 261 517 (n-1)*256+55 HotWaterTemperature °C R 6 262 518 (n-1)*256+66 Room Relative Humidity rH% R7 263 519 (n-1)*256+77 OutletChilledWaterTemperature °C R8 264 520 (n-1)*256+88 Circuit 1 Evaporating Pressure bar R9 265 521 (n-1)*256+99 Circuit 2 Evaporating Pressure bar R10 266 522 (n-1)*256+1010 Circuit 1 Suction Temperature °C R11 267 523 (n-1)*256+1111 Circuit 2 Suction Temperature°C R12 268 524 (n-1)*256+1212 Circuit 1 Evaporating Temperature °C R13 269 525 (n-1)*256+1313 Circuit 2 Evaporating Temperature °C R14 270 526 (n-1)*256+1414 Circuit 1 Superheat °C R15 271 527 (n-1)*256+1515 Circuit 2 Superheat °C R16 272 528 (n-1)*256+1616 Cold Water Valve Ramp % R/W 17 273 529 (n-1)*256+1717 Hot Water Valve Ramp % R/W18 274 530 (n-1)*256+1818 Evaporating Fan Speed % R/W19 275 531 (n-1)*256+1919 Not_used - - 20 276 532 (n-1)*256+2020 CoolingSetpoint °C R/W21 277 533 (n-1)*256+21 21 CoolingSensitivity °C R/W22 278 534 (n-1)*256+2222 Second Cooling Setpoint °C R/W23 279 535 (n-1)*256+2323 HeatingSetpoint °C R/W24 280 536 (n-1)*256+2424 Second Heating setpoint °C R/W25 281 537 (n-1)*256+2525 HeatingSensitivity °C R/W26 282 538 (n-1)*256+2626 High Room Temperature Alarm Threshold(1) °C R/W27 283 539 (n-1)*256+2727 Low Room Temperature Alarm Threshold(1) °C R/W28 284 540 (n-1)*256+2828 Setback Mode: Cooling Setpoint °C R/W29 285 541 (n-1)*256+2929 Setback Mode: Heating Setpoint °C R/W30 286 542 (n-1)*256+3030 CW Setpoint to Start Dehumidification °C R/W31 287 543 (n-1)*256+3131 CW High Temperature Alarm Threshold °C R/W32 288 544 (n-1)*256+3232 CW Setpoint to start CW Operating Mode(Only TC Units)°C R/W33 289 545 (n-1)*256+3333 Radcooler Setpoint in Energy Saving Mode °C R/W34 290 546 (n-1)*256+3434 Radcooler Setpoint in DX Mode °C R/W35 291 547 (n-1)*256+3535 Delivery Temperature Low Limit Setpoint(1) °C R/W36 292 548 (n-1)*256+3636 Delta Temperature for Automatic Mean/LocalChangeover°C R/W37 293 549 (n-1)*256+3737 Serial Transmission Offset R/W38 294 550 (n-1)*256+3838 Notused - - 39 295551(n-1)*256+39 39 Not used- - 40 296 552 (n-1)*256+4040 Not used- - 41 297 553 (n-1)*256+4141 Not used- - 42 298 554 (n-1)*256+4242 Not used- - 43 299 555 (n-1)*256+4343 Not used- - 44 300 556 (n-1)*256+4444 Not used- - 45 301 557 (n-1)*256+4545 Not used- - 46 302 558 (n-1)*256+4646 Not used- - 47 303 559 (n-1)*256+4747 Not used- - 48 304 560 (n-1)*256+4848 Not used- - 49 305 561 (n-1)*256+4949 Not used- - 50 306 562 (n-1)*256+50Only for LAN Unit Number 1:50 LAN Unit 2 Room Temperature °C R 51 307 563 (n-1)*256+5151 LAN Unit 3 Room Temperature °C R52 308 564 (n-1)*256+5252 LAN Unit 4 Room Temperature °C R53 309 565 (n-1)*256+5353 LAN Unit 5 Room Temperature °C R54 310 566 (n-1)*256+5454 LAN Unit 6 Room Temperature °C R55 311 567 (n-1)*256+5555 LAN Unit 7 Room Temperature °C R56 312 568 (n-1)*256+5656 LAN Unit 8 Room Temperature °C R57 313 569 (n-1)*256+5757 LAN Unit 9 Room Temperature °C R58 314 570 (n-1)*256+5858 LAN Unit 10 Room Temperature °C R59 315 571 (n-1)*256+59used - 60 316 572 (n-1)*256+6059 Not60 LAN Unit 2 Room Humidity rH% R61 317 573 (n-1)*256+6161 LAN Unit 3 Room Humidity rH% R62 318 574 (n-1)*256+6262 LAN Unit 4 Room Humidity rH% R63 319 575 (n-1)*256+6363 LAN Unit 5 Room Humidity rH% R64 320 576 (n-1)*256+6464 LAN Unit 6 Room Humidity rH% R65 321 577 (n-1)*256+6565 LAN Unit 7 Room Humidity rH% R66 322 578 (n-1)*256+6666 LAN Unit 8 Room Humidity rH% R67 323 579 (n-1)*256+6767 LAN Unit 9 Room Humidity rH% R68 324 580 (n-1)*256+6868 LAN Unit 10 Room Humidity rH% R69 325 581 (n-1)*256+69 N.B.: all the analog variables are expressed in °C/10 except for those indicated by (1) these one are the expressed in °C.NEW LEONARDO: INTEGER VARIABLES (HOLDING or INPUT REGISTERS)variable address description m.u.variabletypeMODBUS Database(e.g. address -> bit nr.)unit 1unit 2 unit 3 unit n0 NotUsed - - 129385 641 (n-1)*256+128+11 Air Filter Run Hours h R 130386 642 (n-1)*256+128+22 Unit Run Hours h R131387 643 (n-1)*256+128+33 Compressor 1 Run Hours h R132388 644 (n-1)*256+128+44 Compressor 2 Run Hours h R133389 645 (n-1)*256+128+55 Compressor 3 Run Hours h R134390 646 (n-1)*256+128+66 Compressor 4 Run Hours h R135391 646 (n-1)*256+128+77 Heater 1 Run Hours h R136392 648 (n-1)*256+128+88 Heater 2 Run Hours h R137393 649 (n-1)*256+128+99 Humidifier Run Hours h R138394 650 (n-1)*256+128+1010 Notused - - 139395 651 (n-1)*256+128+11 11 Notused - - 140396 652 (n-1)*256+128+12 12 DehumidificationProp.Band rH% R/W 141397 653 (n-1)*256+128+13 13 HumidificationProp.Band rH% R/W142398 654 (n-1)*256+128+1414 High Humidity Alarm Threshold rH% R/W143399 655 (n-1)*256+128+1515 Low Humidity Alarm Threshold rH% R/W144400 656 (n-1)*256+128+1616 DehumidificationSetpoint rH% R/W145401 657 (n-1)*256+128+1717 Setback Mode: Dehumidification Setpoint rH% R/W146402 658 (n-1)*256+128+1818 HumidificationSetpoint rH% R/W147403 659 (n-1)*256+128+1919 Setback Mode: Humidification Setpoint rH% R/W148404 660 (n-1)*256+128+2020 RestartDelay sec R/W149405 661 (n-1)*256+128+21 21 RegulationStartTransitory sec R/W150406 662 (n-1)*256+128+22 22 LowPressureDelay sec R/W151407 663 (n-1)*256+128+2323 Temp./Humid.Limits Alarm Delay min R/W152408 664 (n-1)*256+128+2424 Anti-HuntingConstant min R/W153409 665 (n-1)*256+128+2525 Stand-by Cycle Base Time h R/W154410 666 (n-1)*256+128+2626 NotUsed - - 155411 667 (n-1)*256+128+2627 Number of LAN Units n R/W156412 668 (n-1)*256+128+2828 NotUsed - -157413 669 (n-1)*256+128+2929 Circuit 1 Electronic Valve Position step R 158414 670 (n-1)*256+128+3030 Circuit 2 Electronic Valve Position step R 159415 671 (n-1)*256+128+31。

优力空调操作手册UG30

优力空调操作手册UG30

数字输入–接线头 2 配 10 个 24Vac 数字输入
CW – CW/S ID1 遥控 开 / 关 ID2 气流开关 ID3 过滤器堵塞开关
(CW/S 机组为标准,CW 机组为选项) ID4 电加热器过热保护 ID5 外部温湿度传感器和漏水传感器(选项)报警 ID6 加湿器报警 ID7 --ID8 --ID9 ---
CW – CW/S
DX-DX/S
B1 室内温度 B2 外部温度 – 夏/冬季转换
室内温度 外部温度 – 夏/冬季转换
B3 室内相对湿度
室内相对湿度
B4 STM 送风温度 GND 逻辑输入公共点
STM 送风温度
+V 探头 14Vdc (最大 30mA)的电源输入
数字输出 配有 7 个数字输出:包括 1 个 200 Vac 交流继电器,1 个 200 Vac 常开继电器
UNIFLAIR
UG30 控制器使用手册
UG30 和 mp30 控制器
恒温恒湿精密空调机组
- 冷冻水机组 - 直接膨胀机组
INSTRUCTION MANUAL
使用手册
Mp30-UG30-Rev.1.4-Date: 20-02-2002 CN
1 (39)
UNIFLAIR
UG30 控制器使用手册
关于软件
显示器能显示机组的运行状态和主要参数,用符号和数字及字母组成:
1, 2….
传感器参数
r1,r2…..
调节参数
C9, CA….
压缩机参数
F9, FA…..
风扇参数
P1,P2…..
报警参数
H1,H2….
常用格式化参数
所有控制参数在出厂前已根据具体机组类型设置好;已编定的程序会因硬件键或串行线受影响。如更改

施耐德变频远程面板设置2

施耐德变频远程面板设置2

搅拌机变频本地和远程面板控制的相关设置★本地模式:(显示屏左侧的“给定、监视、配置”模式LED小红灯交替闪烁)1.在非本地模式时,按“模式”按钮3秒钟,显示屏左侧的“给定、监视、配置”模式LED小红灯交替闪烁,进入本地模式,即用变频器上的面板进行操作。

2.按“运行”按钮,变频器进入运行状态,顺时针旋转导航按钮为加频率,逆时针为减频率;按“停止/复位”变频器停止运行。

★远程面板控制模式:(205→02,401→163,308→50,远程面板设频率)在电控柜柜门上安装好远程控制面板并插上通讯电缆后,首次送电时,变频器显示屏左侧的“配置”模式LED小红灯亮起,显示屏上显示“ ”。

1.逆时针轻旋导航按钮至“ ”;2.按下导航按钮,显示屏上显示“ ”;3.顺时针轻旋导航按钮至“ ﹣”;4.按下导航按钮,显示屏上显示“ ”;5.顺时针轻旋导航按钮至“ ”;6.按下导航按钮,显示屏上显示“ ”;7.顺时针轻旋导航按钮至“ ”(R1分配变频器运行);8.按下导航按钮,听到变频器里有轻微的吧嗒声,显示屏上显示“ ”;9.两下○退出按钮,显示屏上出现“ ”;10.按下导航按钮,显示屏上显示“ ”;11.顺时针轻旋导航按钮至“ ﹣”;12.按下导航按钮,显示屏上显示“ ”;13.顺时针轻旋导航按钮至“ ”(最大频率);14.按下导航按钮,显示屏上显示“ ”;15.逆时针轻旋导航按钮至“ ”;16.按下导航按钮,显示屏上显示“ ”;17.两下○退出按钮,显示屏上出现“ ”;18.顺时针轻旋导航按钮至“ ”;19.按下导航按钮,显示屏上显示“ ”;20.顺时针轻旋导航按钮至“ ”(给定通道远程面板);21.按下导航按钮,显示屏上显示“ ”;22.两下○退出按钮,显示屏上出现“﹣﹣ ”;23.此时切换到远程面板上操作24.远程面板上同样显示“﹣﹣ ”;25.按下○ENT键,显示屏左侧的“REF”模式LED小红灯亮起,屏幕显示“ ”;26.按下○ENT键,出现“ ”;27.按○▲键或○▼键调整所需要设定的频率,如“ ”(可调整范围为-400~400,可忽略成0~50)28.按下○ENT键,出现“ ”后显示“ ”;29.按三下○ESC键,显示“﹣﹣ ”(变频器运行时显示运行频率);30.按○RUN键或○STOP键可对变频器进行启停,如需修改频率,可按25~到29步操作如需存客户参数设置,可按如下操作:1.如此时变频器在运行,需按○STOP键停止,如在停止状态即在变频器上的面板操作。

Sepam20&40使用说明手册

Sepam20&40使用说明手册

施耐德SEPAM 20/40系列微机保护装置使用说明手册目录第一章 SEPAM微机保护装置的构造与功能第二章 面板操作说明第三章 运行注意事项及故障显示第四章 保护整定内容及范围第五章 计算机软件的操作附件1:SEPAM保护原理附件2:SEPAM保护继电器测试附件3:富友嘉园10kV中心站保护整定清单3-1:进线保护整定清单3-2:出线保护整定清单3-3:分段保护整定清单3-4:自切保护整定清单附件4:SEPAM 20安装和用户手册附件5:SEPAM 40安装和用户手册1第一章S E PA M微机保护装置的构造与功能S e p a m 20和40保护和测量单元系列产品适用于各种电压等级的工业、商业与民用等公共变电站中电力设备和配电网的保护。

保护、测量、监控等功能详见产品选型表。

S e p a m 20和40系列产品是由保护和测量单元本体和逻辑输入/输出、通讯接口、温度传感器、模拟量输出等扩展模块组成。

保护和测量单元本体是保护、测量、监视及控制的中心处理部分。

它将由各个模块及信号输入所采集的数字和模拟信号加以处理,从而实现保护、测量、监视及控制的功能。

本体正面含有液晶显示面板,操作按钮及状态指示灯;背面含有电压/电流采集输入端子、四个基本的逻辑输出口和连接各种模块的接口。

逻辑输入/输出模块用于各种状态开关量的输入及控制和信号的接点输出。

按照开关量输入所相配合的辅助电源电压等级分为3种类型,分别是:M E S114(24V~250V D C);M E S114E(110V A C/D C);M E S114F(220V A C/D C)。

其模块共有10个逻辑信号输入和4个逻辑信号输出。

2适用Sepam类型名称端子号功能S20 T20 M20 B21,B22逻辑输入I11 M1,M2 分闸位置其他(自定义使用)⑴■■■■■■■■I12 M4,M5 合闸位置其他(自定义使用)⑴■■■■■■■■I13 M7,M8 逻辑分辨, 接收闭锁整定组A/B切换其他(自定义使用) ■■■■■■■■■I14 M10,M11 外部复位外部跳闸4其他(自定义使用) ■■■■■■■■■■■■I21 K1,K2 外部跳闸1外部网络同步其他(自定义使用) ■■■■■■■■■■■■I22 K4,K6 外部跳闸2电动机重起其他(自定义使用) ■■■■■■■■■I23 K4,K7 外部跳闸3瓦斯报警转子旋转方向检测其他(自定义使用) ■■■■■■■■■■I24 K4,K8 储能结束位置温度报警其他(自定义使用) ■■■■■■■■■I25 K4,K9 禁止遥控SF6压力域值1其他(自定义使用) ■■■■■■■■I26 K4,K10 SF6压力域值2热整定切换闭锁热过载保护禁止重合闸其他(自定义使用) ■■■■■■■■■■■■■逻辑输出O1 A4,A5 跳闸其他(自定义使用)⑴■■■■■■■■O2 A7,A8 禁止合闸其他(自定义使用)⑴■■■■■■■■O3 A10,A11 逻辑闭锁输出其他(自定义使用) ■■■■■■■■O4 A13,A14,A15 继电器故障(看门狗)其他(自定义使用) ■■■■■■■■O11 L2,L3 合闸其他(自定义使用)⑴■■■■■■■■O12 L5,L6 其他(自定义使用) ■■■■O13 L8,L9 其他(自定义使用) ■■■■O14 L11,L12 其他(自定义使用) ■■■■注: ⑴ 当使用断路器控制功能时,该功能不可使用。

空调使用说明书

空调使用说明书

空调使用说明书空调使用说明书1、概述1.1 产品介绍本文档是关于空调使用的详细说明,包括产品功能、操作方法和维护注意事项。

1.2 目标读者本文档适用于所有使用本产品的用户。

2、产品安装2.1 准备工作在安装空调之前,请确认以下事项:- 安装位置是否适于空调安装。

- 是否已确认电源和电线符合要求。

2.2 安装步骤请按照以下步骤安装空调:1、定位室内和室外机的安装位置。

2、连接室内和室外机的电线。

3、安装室内和室外机,并确保稳固。

4、连接室内和室外机的冷媒管道。

5、安装空调的遥控器或按键面板。

3、产品使用3.1 遥控器介绍请详细介绍遥控器的各个按钮及功能。

3.2 使用方法请按照以下步骤使用空调:1、打开空调电源。

2、使用遥控器选择合适的模式(制冷、制热、除湿等)。

3、调整温度设置。

4、调整风速和风向。

3.3 温度调节技巧请提供一些建议用于温度调节的技巧,如夏季制冷时的最佳温度设置等。

4、维护和保养4.1 清洁空调请提供清洁空调的方法和频率建议。

4.2 更换滤网请详细说明如何更换空调滤网以保持空气的清洁。

4.3 维修和维护4.3.1 常见故障排除请提供一些常见故障和对应的排除方法。

4.3.2 维修服务请提供维修服务的联系方式和流程。

5、法律名词及注释5.1 法律名词解释在本文档中涉及到的法律名词解释如下:- 消费者权益:指消费者在购买产品时所拥有的权益和保障。

- 产品质量法:指针对产品质量问题所制定的法律法规。

5.2 注释本文档中的注释见附件。

6、结束语感谢您阅读本空调使用说明书。

如有其他问题,请联系我们的客服。

敬请享用愉快!附件:- 注释表本文所涉及的法律名词及注释见附件。

空调面板安装使用说明

空调面板安装使用说明

空调面板安装使用说明一、前言空调面板是空调控制系统中非常重要的组成部分,它可以方便地调节空调的温度、风速、模式等参数。

正确安装和使用空调面板可以确保空调系统的正常运行和高效性能,因此本文将介绍空调面板的安装和使用方法,以便用户正确操作和享受空调系统的舒适。

二、安装1.确认安装位置:选择适合的安装位置,通常应该选在离地面1.5米左右的墙壁上,远离阳光直射和水汽直接接触的地方。

2.准备工具:安装空调面板需要准备的工具有电钻、批丝机、螺丝刀等。

3.安装孔位:使用尺子、水平仪等工具,确定准确的孔位位置,并在墙壁上做好标记。

4.进行钻孔:使用电钻和适当的钻头在标记好的位置上进行钻孔,以安装面板底座螺丝的固定。

5.安装底座:将面板底座按照孔位对齐,使用螺丝刀将它固定在墙上。

6.连接电源:将面板和空调控制系统的电源线连接好,确保连接牢固且无接触不良。

三、使用1.面板开关:使用手指轻触面板开关,即可打开或关闭空调。

2.温度调节:通过触摸面板上的"+"和"-"按键,分别增加或减少设定的温度。

一般每次调整温度为1度。

3.模式选择:面板上通常有多种不同的模式供用户选择,如制冷、制热、抽湿和通风模式。

用户可以根据自己的需求选择合适的模式。

4.风速调节:面板上通常有多个不同的风速档位,用户可以根据需求选择合适的风速。

5.定时设置:一些高级型面板上还会有定时功能,用户可以设置自动开关机的时间,以便在指定的时间内控制空调的运行。

6.温控设置:面板上通常有温度控制设置,可以将室内温度控制在设定的范围内,提高舒适度。

注意事项:1.遥控器使用:在面板上通常会配备遥控器,用户可以通过遥控器远程操作空调面板,提高使用的便利性。

2.避免挤压:在使用过程中,用户应避免面板被重物挤压,以免导致面板损坏或操作不便。

3.定期清洁:定期清洁面板,以保持其外观美观,并避免灰尘和污渍影响面板的使用。

四、故障排除1.面板不工作:检查面板的电源是否接通,并确认电源是否正常。

空调使用手册

空调使用手册

空调使用手册使用手册:空调1. 简介空调是一种常见而实用的家用电器,专门用于调节室内温度和湿度。

本使用手册将为您介绍空调的基本操作方法和注意事项,以确保您能正确、安全地使用空调。

2. 前期准备在使用空调前,请确保以下准备工作已完成:- 确保空调的电源线与插座连接稳固,没有松动或破损;- 清洁空调周围的阻隔物,保持机身周围的通风畅通;- 检查空调滤网,清除灰尘和杂物。

3. 开关机操作- 开机:按下电源键,空调将开始工作并显示当前温度。

您可以使用“Mode”键选择不同的工作模式,如制冷模式、制热模式、送风模式等。

以及设置所需的温度。

- 关机:再按一次电源键,空调将停止运行。

4. 温度调节您可以通过空调控制面板上的温度加减键来调节室内温度。

每按一次键,温度将上下调整1摄氏度。

您也可以通过遥控器上的相应按键来完成温度调节。

5. 模式选择空调通常具有多种工作模式,以满足不同时期和季节的需要。

以下是一些常见的模式选择:- 制冷模式:适用于夏季,通过降低室内温度来达到舒适的效果。

- 制热模式:适用于冬季,通过加热室内空气来提供温暖。

- 除湿模式:适用于潮湿的环境,通过降低室内湿度来提高舒适度。

6. 风速调节空调通常具有多档风速可选,您可以根据个人喜好和需求来调节风速。

- 高风速:适用于需要快速降温或散热的情况。

- 中风速:适用于维持室内舒适温度。

- 低风速:适用于睡眠期间或需要较弱的风力时。

7. 定时开关空调还常常配有定时开关功能,您可以在设定的时间内自动开启或关闭空调。

- 定时开启:按下定时开启键,并设置所需的时间。

空调将在设定的时间自动开启运行。

- 定时关闭:按下定时关闭键,并设置所需的时间。

空调将在设定的时间自动关闭。

8. 其他注意事项- 室内清洁:定期清洁空调周围的灰尘和杂物,以保持通风良好。

- 滤网清洁:定期清洁或更换空调滤网,以确保空气质量和运行效果。

- 注意安全:当空调长时间工作时,机身会变热,请注意避免触碰,以免烫伤。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档