End-to-end Data Protection - HGST Solutions Hard Disk

合集下载

EMC产品介绍 201506

EMC产品介绍 201506
The EMC Answer Book
June 2015
© Copyright 2015 2014 EMC Corporation. All rights reserved. EMC & Partner Internal Use Only
1
Table of Contents
3. 4. 5. 6. 7. 8. 9. EMC Overview EMC Portfolio Our Global Presence WW External Storage & Software Market Share EMC Global Services EMC Global Services : Capabilities & Customer Benefits Education Services
Channels Specialized expertise to build unique solutions; examples: Fujitsu Siemens, Unisys
© Copyright 2015 2014 EMC Corporation. All rights reserved. EMC & Partner Internal Use Only
16. RSA - Advanced Security Operations
17. RSA – Identity Trust Management 18. RSA – Fraud & Risk Intelligence 19. RSA – Governance, Risk & Compliance 20. VMAX3 Family 21. VMAX3 – Customer Benefits 22. VMAX3 Engine Scale Up & Out 23. VMAX3 SRDF Remote Replication 24. VMAX3 All Flash Revolution 25. VMAX3 Massive Storage Density 26. VMAX3 Massive Storage Density 27. Protect Point Backup Revolution 28. Data Protection Backups 29. Snaps Redefined 30. VMAX3 eNAS Overview 31. Unisphere for VMAX With File 32. VPLEX Transforming Continuous Availability 33. VPLEX Overview 34. Oracle RAC With VPLEX 35. VMware With VPLEX 36. Microsoft Applications With VPLEX

HUS磁盘阵列产品说明v

HUS磁盘阵列产品说明v

Hitachi Unified Storage(HUS)日立统一存储产品介绍日立数据系统有限公司2020年4月目录一. 概述 (1)二. HDS HUS 100技术的技术优势 (7)2.1统一存储 (7)2.2独特的动态虚拟控制器和自动负载均衡 (11)2.3系统架构和硬件增强 (13)2.4软件增强部分 (16)2.5面向服务优化的系统 (18)2.6高安全性24×7运行保障 (19)2.7海量容量扩展和灵活的容量管理 (24)2.8SAN环境下的性能优化 (28)2.9安全简便的系统管理 (30)2.10HUS与VMW ARE的紧密结合 (31)三. HDS HUS 100产品技术指标 (43)3.1HUS110 (43)3.2HUS130 (49)3.3HUS150 (54)四. HDS HUS 100突出优势 (60)4.1对磁盘系统的选型依据 (60)4.2HDS HUS存储产品的突出优势 (62)五. HUS场地准备要求 (64)5.1HUS110场地环境说明 (64)5.2HUS130场地环境说明 (67)5.3HUS150场地环境说明 (71)一. 概述日立数据解决方案价值定位今天的数据中心,除了需要面对数据量的急剧增长以及存储基础架构的复杂性之外,如何在统一存储架构中支持多种数据(块数据、文件数据、对象数据)的综合存储需求也是目前大部分企业普遍面临的问题,企业需要在满足传统的高可用性、性能、可扩展性之外,能够从容应对管理、运维以及SLO要求。

Hitachi Data Systems 非常了解企业面临的这些挑战,因此开发了服务导向型存储方法,使应用和业务要求能够与存储属性协调一致。

Hitachi Data Systems推出了Hitachi Unified Storage 100系列存储,以模块化的方式经济高效地为大中型企业提供高效、高可靠的统一存储解决方案。

Hitachi Unified Storage (HUS)100产品家族是HDS中端产品线新一代产品,作为广受欢迎的AMS2000系列的继任者,HUS产品线继承了HDS产品一贯的可靠性、高性能以及无瓶颈的整体优化设计。

D ATA S H E E T

D ATA S H E E T

HostBusAdapter.TheQLE2462istheindustry’sfirst,trueenterpriseclass,4Gbps-to-PCIExpress®x4adapter.TheQLE2462deliversunprecedentedlevelsofperformanceandavailability,aswellasintelligentnetworkingfeaturesspecifictoenterpriseclassdatacenters. EnterpriseClassFeatures.TheQLE2462adapteristhehighestperformingandmostreliableadapterintheindustry.ItdeliversunmatchedperformanceleveragingasingleASICdesign,combininguniquehardwarearchitecturetodeliverover300,000IOPS,nearly1.6GBpsthroughput,andPCIExpressx4busspeeds.Moreimportantly,theQLE2462adapterprovidesnewintelligentstoragenetworkingfeaturesthatredefinetheenterpriseclassadapter,providingincreaseddataprotection,advancedframerouting,andenterprise-widemanagementcapabilities.Setup.Point-and-clickinstallationandconfigurationwizardsadaptersetupprocess.StorageadministratorscanquicklydeployadaptersacrossaSANusingstandardadaptermanagementtoolsutilities.TheQLE2462isfullycompatiblewithSNIAAPIandSMI-S,therebyallowingadministratorstomanageQLogicadaptersusingthird-partysoftwareapplications.ComprehensiveOSSupport.QLogicoffersthebroadestrangeofsupportforallmajoroperatingsystemstoensureOSandhardwareservercompatibility.Driversareavailableforallmajoroperatingsystemsandhardwareserverplatforms.AsingledriverstrategyperOSallowsstorageadministratorstoeasilydeployandmanageadaptersinheterogeneousSANconfigurations.combinedwithagencyandregulatorytesting,ensuresallproductsmeetworldcompliancehardwareandsoftwarespecifications.Alladaptersaretestedextensivelywiththird-partyhardware,alongwithmultiplesoftwareapplications,toensurebest-in-classSANinteroperabilityandcompatibility.YoucanbeconfidentpurchasingQLogicadapterstomeetyourFibreChannelstoragenetworkingneeds.Forover15years,QLogichasbeenatechnologicalcurrentneeds.Inaddition,QLogicprovidesstronginvestmentprotectiontosupportemergingtheindustrywithsuccessfullydeliveringtechnologicalsolutionsthataddresstheneedsoftodayandtomorrow.Corporate Headquarters QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 949.389.6000 Europe Headquarters QLogic (UK) LTD. Quatro House Lyon Way, Frimley Camberley Surrey, GU16 7ER UK +44 (0) 1276 804 670© 2004–2010 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic, the QLogic logo, and SANsurfer are registered trademarks of QLogic Corporation. AMD and Opteron are trademarks or registered trademark of Advanced Micro Devices, Inc. Apple, Mac OS, Power Mac, and Xserve are registered trademarks of Apple, Inc. Cisco is a registered trademark of Cisco Systems, Inc. Citrix and XenServer are trademarks or registered trademarks of Citrix Systems, Inc. Linux is a registered trademark of Linus Torvalds. Oracle is a registerd trademark of Oracle Corporataion. PCI Express is a registered trademark of PCI-SIG Corporation. Red Hat is a registered trademark of Red Hat, Inc. Solaris and OpenSolaris are trademarks or registered trademarks of Sun Microsystems, Inc. SPARC is a registered trademark of SPARC International, Inc. SUSE, Novell, and NetWare are registered trademarks of Novell, Inc. VMware, and ESX are trademarks or registered trademarks of VMware, Inc. Windows, Windows Server, and Windows Vista are registered trademarks of Microsoft Corporation. All other brand and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic Corporation is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to make changes in product design or specifications.PX2458003-00P2。

HDS公司、产品、解决方案(基础版)

HDS公司、产品、解决方案(基础版)
Average latency Random read seek time Random write seek time 可靠性 MTBF Annual Failure Rate 电源 18 Maximum start current, AC
Source: Seagate
146GB SAS硬盘
ST3146356SS SAS 3Gb/s x 2 (双活端口) 16 MBytes 146 GB 165 Gbits/inch2
HDS产品与解决方案
通用版本
© 2009 Hitachi Data Systems
日立数据系统公司
• 1989年成立于美国硅谷(美国国家半导体子公司)是 专业存储解决方案提供商,涉及硬件、软件和专业 服务,目前在高端存储市场份额第一。
• 承传30余年大型主机设计及制造经验,在全球 170+ 个国家为用户提供产品和服务
,造成整体性能瓶颈;
• 潜在增加计划内和计划外应用宕机时间
– 单通道下控制器微码无法在线升级 – 故障切换带来应用中断
• 前后端主机接口类型单一,同一端口无法支持 不同平台主机
• 后端磁盘接口带宽与并发访问能力限制,环路 6 性能瓶颈
Path Path
前后端 控制卡
CTL#0
Path Path
前后端 控制卡
Hitachi Universal Storage Platform VM
智能虚拟化 存储系统
USP VM
Hitachi Universal Storage Platform V USP V
高级中端 存储系统
Hitachi Adaptable Modular Storage
AMS2100
AMS2300

HDS产品优势介绍

HDS产品优势介绍

RAID Processor (Hi-PER)
DX2
200 MB/s (1 loop x 200 MB/s)
Switch Hub
1066 MB/s x 2 15 HDD
RAID Processor (Hi-PER)
3.2 GB/s
2 GB Cache
DX2
Switch Hub
PCI-X
PowerPC 500MHz
• 2 repair slots for replacement HDDs
• RAID-6, any two drives can fail without data loss
• Runs for 4 years or longer without required maintenance or repair
OEM LSI & DotHill SE 9900 OEM Hitachi
8
2000-2007:日立在高端存储拔得头筹
High-end Enterprise Disk Storage Share (End-users)
75.0% 72.5% 70.0% 67.5% 65.0% 62.5% 60.0% 57.5% 55.0% 52.5% 50.0% 47.5% 45.0% 42.5% 40.0% 37.5% 35.0% 32.5% 30.0% 27.5% 25.0% 22.5% 20.0% 17.5% 15.0% 12.5% 10.0%
SUN N/A SE9910 SE9960 SE9970 SE9980 SE9985 SE9990 SE9990V
7
各厂商磁盘产品
厂商 HDS EMC IBM HP SUN
中低端
高端

McAfee数据保护---端点加密解决方案

McAfee数据保护---端点加密解决方案

Simple Architecture
SafeBoot Client SafeBoot Client
Dynamic IP address Listening Port: 5556 (configurable)
Dynamic IP address Listening Port: 5556 (configurable)
Financial Services / Insurance Technology Manufacturing Telecoms / Utilities Business Services and Consulting Retail Healthcare
Note: * Based on Forbes Global Top 2000 list as of 2007
Windows Boot Up
SafeBoot Client Agent starts
Load User Profile
SB Client tries contacting the SafeBoot Server
SafeBoot® on the PC/Laptop

Client Boot Sequence
SafeBoot PreBoot Screen
Username: Jiexin256 Password: *******
Authentication takes place
SafeBoot Key loaded
SafeBoot loads Original MBR
Microsoft PKI Entrust PKI Active Directory Novell NDS LDAP
SafeBoot® Administration

HGST Ultrastar He 6 氦气密封式硬盘

HGST Ultrastar He 6 氦气密封式硬盘

HGST Ultrastar He 6 氦气密封式硬盘作者:暂无来源:《计算机世界》 2014年第25期HGST(昱科环球存储科技有限公司,前身为日立环球存储科技公司)是全球第一块硬盘的发明者。

借助其卓越的技术传承,HGST 为信息时代的来临带来了存储技术的革新,以满足社交网络、云服务、互联网服务供应商、移动设备、大数据及企业业务交易的需求。

HGST 的产品质量可靠,产品组合覆盖各类高质量硬盘和固态硬盘,为消费者以及企业的重要数据提供了安全高效的存储、管理及保护。

HGST 致力于为全球最大最先进的技术企业提供个性化的存储解决方案及高端存储基础设施咨询服务。

通过与客户直接合作以及与渠道合作伙伴的协作,HGST推出了创新的云存储器、数据中心、移动计算、台式电脑、消费类电子产品以及个人存储设备,创造了极大价值。

HGST 公司创立于2003 年,公司总部位于美国加州圣荷西。

随着云、移动设备、大数据和社交媒体推动数据的爆炸式增长,数据中心客户正在不断寻求如何经济高效地降低存储基础设施成本并提高效益。

这些数据中心客户必须部署容量极高、TCO(总体拥有成本)最佳的存储设施,而对于TCO 来说,有些数值则尤为重要,如每TB 的成本及能耗、单位系统重量的存储容量和每平方英尺的存储容量。

HGST 利用空气动力学研究成果解决了这一问题,使用氦气,大幅提升硬盘容量并降低总拥有成本。

目前的所有硬盘均密封空气,其存储密度也已经达到了极限。

而通过利用材料科学、机械工程和工艺工程领域的研究成果,HGST 率先推出了Ultrastar He6 氦气密封式硬盘。

与使用空气的传统硬盘解决方案相比,HGST 氦气密封硬盘拥有众多优势。

氦气的密度是空气的1/7。

较小的密度意味着作用在机械组件上的振动或干扰更小,这也意味着这些组件可以做得更加轻薄,因此可在相同高度的硬盘盒内放入更多盘片。

磁盘转轴上的阻力变得更小,所以能耗也得到了降低。

机械能耗降低了25%,容量可增加40%,因此W/TB 可减少45%。

联想ThinkSystem DE2000H混合存储阵列产品指南说明书

联想ThinkSystem DE2000H混合存储阵列产品指南说明书

Lenovo ThinkSystem DE2000H Hybrid Storage Array Product GuideLenovo ThinkSystem DE2000H is a low-cost, hybrid entry-level storage system that is designed to provide performance, simplicity, capacity, security, and high availability for small to large businesses. It delivers enterprise-class storage management capabilities with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features. The ThinkSystem DE2000H is a perfect fit for small offices and remote and branch offices of large enterprises that run a wide range of workloads, including big data and analytics, video surveillance, technical computing, backup and recovery, and other storage I/O-intensive applications.ThinkSystem DE2000H models are available in a 2U rack form-factor with 24 small form-factor (2.5-inch SFF) drives (2U24 SFF) or 12 large form-factor (3.5-inch LFF) drives (2U12 LFF) and include two controllers, each with 8 GB memory for a system total of 16 GB. Host interface cards provide 12 Gb SAS, 10/25 Gb iSCSI, or 8/16/32 Gb FC connections.The ThinkSystem DE2000H Storage Array scales up to 96 drives with the attachment of Lenovo ThinkSystem DE120S 2U12 and DE240S 2U24 SFF Expansion Enclosures. It also offers flexible drive configurations with the choice of 2.5-inch (SFF) and 3.5-inch (LFF) form factors, 10 K rpm SAS and 7.2 K rpm NL SAS hard disk drives (HDDs), and SAS solid-state drives (SSDs).Figure 1. Lenovo ThinkSystem DE2000H 2U24 SFF (top) and 2U12 LFF (bottom) enclosuresDid you know?The ThinkSystem DE2000H scales up to 1.47 PB of raw storage capacity.The ThinkSystem DE2000H offers block storage connectivity with support for 10/25 Gb iSCSI SFP28,8/16/32 Gb FC, or 12 Gb SAS, or 1/10 Gb iSCSI RJ-45 technologies.Click here to check for updatesFigure 2. ThinkSystem DE2000H and DE240S 2U SFF enclosures front viewThe front of the ThinkSystem DE2000H and DE240S 2U SFF enclosures includes the following components:24 SFF hot-swap drive baysEnclosure status LEDsEnclosure ID LEDFigure 3. ThinkSystem DE2000H and DE120S 2U LFF enclosures front viewThe front of the ThinkSystem DE2000H and DE120S 2U LFF enclosures includes the following components:12 LFF hot-swap drive baysEnclosure status LEDsEnclosure ID LEDFigure 4. Rear view ThinkSystem DE2000H 2U controller enclosure with two Gen2 controllers installed The rear of the ThinkSystem DE2000H 2U controller enclosure includes the following components: Two redundant hot-swap controllers, each with the following ports:One slot for a host interface cardNote: The DE2000H Gen2 controllers no longer offers base portsTwo 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644) for connections to theexpansion enclosures.One RJ-45 10/100/1000 Mb Ethernet port for out-of-band management.Note: The Ethernet port (P2) next to the GbE management port is not available for use.Two serial console ports (RJ-45 and Micro-USB) for another means to configure the system.One USB Type A port (reserved for factory use)Two redundant hot-swap 913 W (100 - 240 V) AC power supplies (IEC 320-C14 power connector) with integrated cooling fans.Figure 5. ThinkSystem DE240S or DE120S 2U expansion enclosure rear viewThe rear of the ThinkSystem DE240S or DE120S 2U expansion enclosure includes the following components:Two redundant hot-swap I/O Modules; each I/O Module provides four 12 Gb SAS x4 expansion ports (Mini-SAS HD SFF-8644) for connections to the controller enclosures and for connecting the expansion enclosures between each other.Two redundant hot-swap 913 W (100 - 240 V) AC power supplies (IEC 320-C14 power connector) with integrated cooling fans.4C57A14367B4B8Lenovo ThinkSystem DE2000/4000 HIC, 12Gb SAS,4-ports 24C57A14369B4BA Lenovo ThinkSystem DE2000/4000 HIC, 10/25GbE iSCSI,4-ports 24C57A14368B4B9Lenovo ThinkSystem DE2000/4000 HIC, 32Gb FC,4-ports 2SFP+ options for 10 Gb iSCSI / 16 Gb FC host interface card / 32 Gb FC host interface card 4M17A13527B4B2Lenovo 10Gb iSCSI/16Gb FC Universal SFP+ Module 8SFP28 options for 10/25 Gb iSCSI host interface card 4M17A13529B4B4Lenovo 10/25GbE iSCSI SFP28 Module 8SFP+ options for 32 Gb FC host interface card4M17A13528B4B3Lenovo 32Gb FC SFP+ Transceiver 8OM4 cable options for 16/32 Gb FC and 10/25 Gb iSCSI SW SFP+/SFP28 optical transceivers4Z57A10845B2P9Lenovo 0.5m LC-LC OM4 MMF Cable 44Z57A10846B2PA Lenovo 1m LC-LC OM4 MMF Cable 44Z57A10847B2PB Lenovo 3m LC-LC OM4 MMF Cable 44Z57A10848B2PC Lenovo 5m LC-LC OM4 MMF Cable 44Z57A10849B2PD Lenovo 10m LC-LC OM4 MMF Cable 44Z57A10850B2PE Lenovo 15m LC-LC OM4 MMF Cable 44Z57A10851B2PF Lenovo 25m LC-LC OM4 MMF Cable 44Z57A10852B2PG Lenovo 30m LC-LC OM4 MMF Cable 4OM3 cable options for 16/32 Gb FC and 10/25 Gb iSCSI SW SFP+/SFP28 optical transceivers00MN499ASR5Lenovo 0.5m LC-LC OM3 MMF Cable 400MN502ASR6Lenovo 1m LC-LC OM3 MMF Cable 400MN505ASR7Lenovo 3m LC-LC OM3 MMF Cable 400MN508ASR8Lenovo 5m LC-LC OM3 MMF Cable 400MN511ASR9Lenovo 10m LC-LC OM3 MMF Cable 400MN514ASRA Lenovo 15m LC-LC OM3 MMF Cable 400MN517ASRB Lenovo 25m LC-LC OM3 MMF Cable 400MN520ASRC Lenovo 30m LC-LC OM3 MMF Cable 4DAC cable options for 10 Gb iSCSI SFP+ host connectivity (iSCSI HICs)00D6288A3RG 0.5m Passive DAC SFP+ Cable 490Y9427A1PH 1m Passive DAC SFP+ Cable 400AY764A51N 1.5m Passive DAC SFP+ Cable 400AY765A51P 2m Passive DAC SFP+ Cable 490Y9430A1PJ 3m Passive DAC SFP+ Cable 490Y9433A1PK 5m Passive DAC SFP+ Cable 400D6151A3RH7m Passive DAC SFP+ Cable4DAC cable options for 25 Gb iSCSI SFP28 host connectivity (iSCSI HICs)7Z57A03557AV1W Lenovo 1m Passive 25G SFP28 DAC Cable 87Z57A03558AV1XLenovo 3m Passive 25G SFP28 DAC Cable8SAS host connectivity cables: Mini-SAS HD (controller) to Mini-SAS HD (host)Part number Featurecode DescriptionMaximum quantity per controller enclosure00YL847AU160.5m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 400YL848AU171m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 400YL849AU182m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 400YL850AU193m External MiniSAS HD 8644/MiniSAS HD 8644 Cable 4UTP Category 6 cables for 1/10 Gb iSCSI RJ-45 connectivity and 1 GbE management ports00WE123AVFW 0.75m Green Cat6 Cable 600WE127AVFX 1.0m Green Cat6 Cable 600WE131AVFY 1.25m Green Cat6 Cable 600WE135AVFZ 1.5m Green Cat6 Cable 600WE139AVG03m Green Cat6 Cable 690Y3718A1MT 10m Green Cat6 Cable 690Y3727A1MW25m Green Cat6 Cable6Part number Featurecode DescriptionMaximum quantity per controller enclosure * Factory-installed only.Expansion enclosuresThe ThinkSystem DE2000H supports attachment of up to three 2U expansion enclosures (ThinkSystem DE240S 2U24 SFF, ThinkSystem DE120S 2U12 LFF, or a combination of the ThinkSystem DE240S and DE120S). Intermix of 2U24 SFF and 2U12 LFF expansion enclosures behind a 2U24 SFF or 2U12 LFF controller enclosure is supported. The expansion enclosures can be added to the system non-disruptively.The following table lists the relationship models of the supported ThinkSystem DE Series expansion enclosures.Table 5. ThinkSystem DE240S and DE120S relationship modelsDescriptionPart numberWorldwideEuropean UnionJapanLenovo ThinkSystem DE240S 2U24 SFF Expansion Enclosure 7Y68A000WW 7Y68A004EA 7Y681001JP Lenovo ThinkSystem DE120S 2U12 LFF Expansion Enclosure7Y63A000WW 7Y63A003EA 7Y631000JPThe following table lists the TopSeller models of the supported ThinkSystem DE Series expansion enclosures.Table 6. ThinkSystem DE240S and DE120S TopSeller models: Brazil and Latin AmericaDescriptionPart numberLatin America Brazil Lenovo ThinkSystem DE240S 2U24 SFF Expansion Enclosure (TopSeller)7Y681002LA 7Y681002BR Lenovo ThinkSystem DE120S 2U12 LFF Expansion Enclosure (TopSeller)7Y631001LA7Y631001BRFigure 6. DE Series expansion enclosure connectivity topologyThe following table lists ordering information for the supported expansion enclosure connectivity options. Table 8. Expansion unit connectivity optionsDescription Part numberExternal MiniSAS HD 8644/MiniSAS HD 8644 0.5M Cable00YL847 External MiniSAS HD 8644/MiniSAS HD 8644 1M Cable00YL848 External MiniSAS HD 8644/MiniSAS HD 8644 2M Cable00YL849 External MiniSAS HD 8644/MiniSAS HD 8644 3M Cable00YL850DrivesThe ThinkSystem DE Series 2U24 SFF enclosures support up to 24 SFF hot-swap drives, and the 2U12 LFF enclosures support up to 12 LFF hot-swap drives.The following table lists supported drive options for the 2U24 SFF controller and expansion enclosures. Table 9. 2U24 SFF drive optionsPart number Featurecode DescriptionMaximumquantity per2U24 SFFenclosure2.5-inch 12 Gbps SAS hot-swap HDDs4XB7A14112B4BY Lenovo ThinkSystem DE Series 1.2TB 10K 2.5" HDD 2U2424 4XB7A14113B4BZ Lenovo ThinkSystem DE Series 1.8TB 10K 2.5" HDD 2U2424 4XB7A88046BW12Lenovo ThinkSystem DE Series 2.4TB 10K 2.5" HDD 2U2424 2.5-inch 12 Gbps SAS hot-swap FIPS HDDs (SED HDDs)4XB7A14114B4C0Lenovo ThinkSystem DE Series 1.8TB 10K 2.5" HDD FIPS 2U2424 4XB7A88048BW13Lenovo ThinkSystem DE Series 2.4TB 10K 2.5" HDD FIPS 2U2424 2.5-inch 12 Gbps SAS hot-swap SSDs (1 DWPD and 3 DWPD)4XB7A74948BKUQ Lenovo ThinkSystem DE Series 960GB 1DWD 2.5" SSD 2U2424 4XB7A74951BKUT Lenovo ThinkSystem DE Series 1.92TB 1DWD 2.5" SSD 2U2424 4XB7A74955BKUK Lenovo ThinkSystem DE Series 3.84TB 1DWD 2.5" SSD 2U2424 4XB7A14176B4RY Lenovo ThinkSystem DE Series 7.68TB 1DWD 2.5" SSD 2U2424 4XB7A14110B4CD Lenovo ThinkSystem DE Series 15.36TB 1DWD 2.5" SSD 2U2424 2.5-inch 12 Gbps SAS hot-swap FIPS SSDs (SED SSDs)4XB7A14107B4BV Lenovo ThinkSystem DE Series 1.6TB 3DWD 2.5" SSD FIPS 2U2424Power supplies and cablesThe ThinkSystem DE Series 2U24 SFF and 2U12 LFF enclosures ship with two redundant hot-swap 913 W (100 - 240 V) Platinum AC power supplies, each with an IEC 320-C14 connector. The Relationship and TopSeller models of the ThinkSystem DE2000H 2U24 SFF and 2U12 LFF, DE240S 2U24 SFF, andDE120S LFF enclosures listed in Controller enclosures and Expansion enclosures ship with two 1.5 m, 10A/100-250V, C13 to IEC 320-C14 rack power cables.The CTO models require the selection of two power cables.The following table lists the rack power cable and line cord options that can be ordered for the DE Series 2U24 SFF and 2U12 LFF enclosures (two power cords per enclosure).Table 12. Power cables for DE Series 2U24 SFF and 2U12 LFF enclosuresDescription PartnumberFeaturecodeRack power cables1.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable00Y3043A4VP 1.0m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable4L67A08367B0N5 1.5m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable39Y793762011.5m, 13A/100-250V, C13 to IEC 320-C14 Rack Power Cable4L67A08368B0N62.0m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable4L67A08365B0N4 2.0m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable4L67A083696570 2.8m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable4L67A083666311 2.8m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable4L67A083706400 2.8m, 10A/100-250V, C13 to IEC 320-C20 Rack Power Cable39Y79386204 4.3m, 10A/100-250V, C13 to IEC 320-C14 Rack Power Cable39Y79326263 4.3m, 13A/125V-10A/250V, C13 to IEC 320-C14 Rack Power Cable4L67A083716583 Line cordsArgentina 2.8m, 10A/250V, C13 to IRAM 2073 Line Cord39Y79306222 Argentina 4.3m, 10A/250V, C13 to IRAM 2073 Line Cord81Y23846492 Australia/New Zealand 2.8m, 10A/250V, C13 to AS/NZS 3112 Line Cord39Y79246211 Australia/New Zealand 4.3m, 10A/250V, C13 to AS/NZS 3112 Line Cord81Y23836574 Brazil 2.8m, 10A/250V, C13 to NBR 14136 Line Cord69Y19886532 Brazil 4.3m, 10A/250V, C13 to NBR14136 Line Cord81Y23876404 China 2.8m, 10A/250V, C13 to GB 2099.1 Line Cord39Y79286210 China 4.3m, 10A/250V, C13 to GB 2099.1 Line Cord81Y23786580 Denmark 2.8m, 10A/250V, C13 to DK2-5a Line Cord39Y79186213 Denmark 4.3m, 10A/250V, C13 to DK2-5a Line Cord81Y23826575 Europe 2.8m, 10A/250V, C13 to CEE7-VII Line Cord39Y79176212 Europe 4.3m, 10A/250V, C13 to CEE7-VII Line Cord81Y23766572 India 2.8m, 10A/250V, C13 to IS 6538 Line Cord39Y79276269 India 4.3m, 10A/250V, C13 to IS 6538 Line Cord81Y23866567 Israel 2.8m, 10A/250V, C13 to SI 32 Line Cord39Y79206218 Israel 4.3m, 10A/250V, C13 to SI 32 Line Cord81Y23816579 Italy 2.8m, 10A/250V, C13 to CEI 23-16 Line Cord39Y79216217Italy 4.3m, 10A/250V, C13 to CEI 23-16 Line Cord 81Y23806493Japan 2.8m, 12A/125V, C13 to JIS C-8303 Line cord 46M2593A1RE Japan 2.8m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A083576533Japan 4.3m, 12A/125V, C13 to JIS C-8303 Line Cord 39Y79266335Japan 4.3m, 12A/250V, C13 to JIS C-8303 Line Cord 4L67A083626495Korea 2.8m, 12A/250V, C13 to KS C8305 Line Cord 39Y79256219Korea 4.3m, 12A/250V, C13 to KS C8305 Line Cord 81Y23856494South Africa 2.8m, 10A/250V, C13 to SABS 164 Line Cord 39Y79226214South Africa 4.3m, 10A/250V, C13 to SABS 164 Line Cord 81Y23796576Switzerland 2.8m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 39Y79196216Switzerland 4.3m, 10A/250V, C13 to SEV 1011-S24507 Line Cord 81Y23906578Taiwan 2.8m, 10A/125V, C13 to CNS 10917-3 Line Cord 23R71586386Taiwan 2.8m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y23756317Taiwan 2.8m, 15A/125V, C13 to CNS 10917-3 Line Cord 81Y23746402Taiwan 4.3m, 10A/125V, C13 to CNS 10917-3 Line Cord 4L67A08363AX8BTaiwan 4.3m, 10A/250V, C13 to CNS 10917-3 Line Cord 81Y23896531Taiwan 4.3m, 15A/125V, C13 to CNS 10917-3 Line Cord 81Y23886530United Kingdom 2.8m, 10A/250V, C13 to BS 1363/A Line Cord 39Y79236215United Kingdom 4.3m, 10A/250V, C13 to BS 1363/A Line Cord 81Y23776577United States 2.8m, 10A/125V, C13 to NEMA 5-15P Line Cord 90Y30166313United States 2.8m, 10A/250V, C13 to NEMA 6-15P Line Cord 46M2592A1RF United States 2.8m, 13A/125V, C13 to NEMA 5-15P Line Cord 00WH5456401United States 4.3m, 10A/125V, C13 to NEMA 5-15P Line Cord 4L67A083596370United States 4.3m, 10A/250V, C13 to NEMA 6-15P Line Cord 4L67A083616373United States 4.3m, 13A/125V, C13 to NEMA 5-15P Line Cord4L67A08360AX8ADescriptionPart number Feature code Rack installationThe individually shipped ThinkSystem DE Series 2U12 enclosures ship with the ThinkSystem Storage Rack Mount Kit 2U12, and the individually shipped ThinkSystem DE Series 2U24 enclosures ship with the ThinkSystem Storage Rack Mount Kit 2U24/4U60. The rack mount kits are listed in the following table.Table 13. 4-post rack mount kitsDescriptionFeature code Quantity Lenovo ThinkSystem Storage Rack Mount Kit 2U12B38X 1Lenovo ThinkSystem Storage Rack Mount Kit 2U24/4U60B38Y1When the ThinkSystem DE Series enclosures are factory-integrated and shipped installed in a rack cabinet, the rack mount kits that support Ship-in-Rack (SIR) capabilities are derived by the configurator. The SIR-capable rack mount kits are listed in the following table.Table 14. 4-post SIR rack mount kitsDescription Featurecode QuantityLenovo ThinkSystem Storage Rack Mount Kit 2U12B38X1 Lenovo ThinkSystem Storage SIR Rack Mount Kit (for 2U24 enclosures)B6TH1The following table summarizes the rack mount kit features and specifications.Table 15. Rack mount kit features and specifications summaryAttribute Screw-in fixed rail with adjustable depth2U122U24/4U602U24 SIRFeature code B38X B38Y B6THEnclosure support DE2000H 2U LFFDE120S DE2000H 2U SFFDE240SDE2000H 2U SFFDE240SRail type Fixed (static) withadjustable depth Fixed (static) withadjustable depthFixed (static) withadjustable depthTool-less installation No No NoIn-rack maintenance Yes*Yes*Yes* Ship-in-rack (SIR) support Yes No Yes1U PDU support Yes Yes Yes0U PDU support Limited**Limited**Limited**Rack type IBM or Lenovo 4-post,IEC standard-compliant IBM or Lenovo 4-post,IEC standard-compliantIBM or Lenovo 4-post,IEC standard-compliantMounting holes Square or round Square or round Square or roundMounting flange thickness 2 mm (0.08 in.) –3.3 mm (0.13 in.)2 mm (0.08 in.) –3.3 mm (0.13 in.)2 mm (0.08 in.) –3.3 mm (0.13 in.)Distance between front and rear mounting flanges^605 mm (23.8 in.) –812.8 mm (32 in.)605 mm (23.8 in.) –812.8 mm (32 in.)605 mm (23.8 in.) –812.8 mm (32 in.)* The majority of the enclosure components can be serviced from the front or rear of the enclosure, which does not require the removal of the enclosure from the rack cabinet.** If a 0U PDU is used, the rack cabinet must be at least 1000 mm (39.37 in.) deep for 2U12 and 2U24 enclosures.^ Measured when mounted on the rack, from the front surface of the front mounting flange to the rear most point of the rail. Physical specificationsRack cabinetsThe following table lists the supported rack cabinets.Table 17. Rack cabinetsPart number Description93072RX 25U Standard Rack (1000mm)93072PX 25U Static S2 Standard Rack (1000mm)7D6DA007WW ThinkSystem 42U Onyx Primary Heavy Duty Rack Cabinet (1200mm)7D6DA008WW ThinkSystem 42U Pearl Primary Heavy Duty Rack Cabinet (1200mm)93604PX 42U 1200mm Deep Dynamic Rack 93614PX 42U 1200mm Deep Static Rack 93634PX 42U 1100mm Dynamic Rack93634EX 42U 1100mm Dynamic Expansion Rack 93074RX 42U Standard Rack (1000mm)7D6EA009WW ThinkSystem 48U Onyx Primary Heavy Duty Rack Cabinet (1200mm)7D6EA00AWWThinkSystem 48U Pearl Primary Heavy Duty Rack Cabinet (1200mm)For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:https:///lp1287-lenovo-rack-cabinet-referenceFor more information, see the list of Product Guides in the Rack cabinets category:https:///servers/options/racksPower distribution unitsThe following table lists the power distribution units (PDUs) that are offered by Lenovo.Table 18. Power distribution unitsPart number Feature code Description 0U Basic PDUs00YJ776ATZY 0U 36 C13/6 C19 24A 1 Phase PDU N Y Y N N N N N N Y Y Y N 00YJ777ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y 00YJ778AU000U 21 C13/12 C19 32A 3 Phase PDU Y Y N Y Y Y Y Y Y N N Y Y 0U Switched and Monitored PDUs00YJ783AU040U 12 C13/12 C19 Switched and Monitored48A 3 Phase PDUN N Y N N N Y N N Y Y Y N 00YJ781AU030U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDUN N Y N Y N Y N N Y Y Y N 00YJ782AU020U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDUY Y Y Y Y Y Y Y Y N Y N Y 00YJ780AU010U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDUY Y Y Y Y Y Y Y Y N Y N Y1U Switched and Monitored PDUsA N ZA S E A NB r a z i l E E TM E AR U C I S W EH T KI N D I A J A P A NL AN A P R C4PU7A81117BNDV1U 18 C19/C13 switched and monitored 48A3P WYE PDU - ETLN N N N N N N N N N N Y N4PU7A77467BLC41U 18 C19/C13 Switched and Monitored 80A3P Delta PDUN N N N N N N N N Y N Y N4PU7A77469BLC61U 12 C19/C13 switched and monitored 60A3P Delta PDUN N N N N N N N N N N Y N4PU7A77468BLC51U 12 C19/C13 switched and monitored 32A3P WYE PDUY Y Y Y Y Y Y Y Y N Y Y Y4PU7A81118BNDW1U 18 C19/C13 switched and monitored 48A3P WYE PDU - CEY Y Y Y Y Y Y Y Y N Y N Y 1U Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)71763NU6051Ultra Density Enterprise C19/C13 PDU60A/208V/3PHN N Y N N N N N N Y Y Y N71762NX6091Ultra Density Enterprise C19/C13 PDUModuleY Y Y Y Y Y Y Y Y Y Y Y Y 1U C13 Enterprise PDUs (12x IEC 320 C13 outlets)39M28166030DPI C13 Enterprise PDU Plus Module (WW)Y Y Y Y Y Y Y Y Y Y Y Y Y 39Y89416010DPI C13 Enterprise PDU Module (WW)Y Y Y Y Y Y Y Y Y Y Y Y Y 1U C19 Enterprise PDUs (6x IEC 320 C19 outlets)39Y89486060DPI C19 Enterprise PDU Module (WW)Y Y Y Y Y Y Y Y Y Y Y Y Y 1U Front-end PDUs (3x IEC 320 C19 outlets)39Y89386002DPI Single-phase 30A/120V Front-end PDU(US)Y Y Y Y Y Y Y Y Y Y Y Y Y39Y89396003DPI Single-phase 30A/208V Front-end PDU(US)Y Y Y Y Y Y Y Y Y Y Y Y Y39Y89346005DPI Single-phase 32A/230V Front-end PDU(International)Y Y Y Y Y Y Y Y Y Y Y Y Y39Y89406004DPI Single-phase 60A/208V Front-end PDU(US)Y N Y Y Y Y Y N N Y Y Y N39Y89356006DPI Single-phase 63A/230V Front-end PDU(International)Y Y Y Y Y Y Y Y Y Y Y Y Y 1U NEMA PDUs (6x NEMA 5-15R outlets)39Y89055900DPI 100-127V NEMA PDU Y Y Y Y Y Y Y Y Y Y Y Y Y Line cords for 1U PDUs that ship without a line cord40K96116504 4.3m, 32A/380-415V, EPDU/IEC 3093P+N+G 3ph wye (non-US) Line CordY Y Y Y Y Y Y Y Y Y Y Y Y40K96126502 4.3m, 32A/230V, EPDU to IEC 309 P+N+G(non-US) Line CordY Y Y Y Y Y Y Y Y Y Y Y Y40K96136503 4.3m, 63A/230V, EPDU to IEC 309 P+N+G(non-US) Line CordY Y Y Y Y Y Y Y Y Y Y Y Y40K96146500 4.3m, 30A/208V, EPDU to NEMA L6-30P(US) Line CordY Y Y Y Y Y Y Y Y Y Y Y Y40K96156501 4.3m, 60A/208V, EPDU to IEC 309 2P+G(US) Line Cord N N Y N N N Y N N Y Y Y NPart number Featurecode Description ANZASEABraziEETMEARUCIWEHTKINDIAJAPALANAPRC40K96176505 4.3m, 32A/230V, Souriau UTG Female toAS/NZ 3112 (Aus/NZ) Line Cord Y Y Y Y Y Y Y Y Y Y Y Y Y 40K961865064.3m, 32A/250V, Souriau UTG Female to KSC 8305 (S. Korea) Line CordY Y Y Y Y Y Y Y Y Y Y Y YPart number Feature code Description For more information, see the Lenovo Press documents in the PDU category:https:///servers/options/pduUninterruptible power supply unitsThe following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.Table 19. Uninterruptible power supply unitsPart number Description55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)55943KT†ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)55943LT†ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C1916A outlets)55946KT†ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)5594XKT†ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)† Only available in China and the Asia Pacific market.For more information, see the list of Product Guides in the UPS category:https:///servers/options/upsLenovo Financial ServicesA N ZA S E AB r a z i E E TM E AR U C I W EH T KI N D I A J A P A L AN A P R CTrademarksLenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web athttps:///us/en/legal/copytrade/.The following terms are trademarks of Lenovo in the United States, other countries, or both:Lenovo®Flex SystemLenovo ServicesSystem x®ThinkSystem®TopSellerXClarity®The following terms are trademarks of other companies:Linux® is the trademark of Linus Torvalds in the U.S. and other countries.Excel®, Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.Lenovo ThinkSystem DE2000H Hybrid Storage Array31。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

End-to-end Data Protection | 1End-to-end Data ProtectionDan ColegroveSenior Technical Staff Member

Introduction

End-to-end Data Protection is a new feature in SAS and Fibre Channel hard drives that extends error detec-tion to cover the entire path from the computer system to the hard drive media and back. Data protection information is appended to the data in the computer system. It stays with the data from the computer, through Fibre Channel or SAS connections, through RAID controllers, and through drive electronics to the drive media. When read, the same data protection information returns with the data to the computer sys-tem. The protection information is used to verify the correctness of the data at multiple points in the path.

Error Detection at the Hard DriveFor the first time, hard drives can detect an error created anywhere in the path before it is written to the drive media and before sending erroneous data back to the computer system.

Some storage systems without End-to-end Data Protection attach proprietary error-checking information to user data. The disadvantage of error checking that takes place only in the computer system is that hard drives can not understand the proprietary checking information, so they can not detect an error that oc-curred between the computer and the drive or check the proprietary information when data is read, before sending it to the computer system.

End-to-end, EDP and DIF are the Same End-to-end Data Protection is also known as EDP or the Data Protection Model. During development it was also referred to as Data Integrity Field or DIF.

Error IsolationErrors can be isolated to the host adapter, RAID controller or hard drive. As a standard feature, each device in the path from system to drive can check and report a data error (Figure 1). This simplifies isolation of the component that had the error. This allows for multiple points of failure isolation:

1. As it passes through intermediate devices (RAID Controllers)2. Before it is written to the hard drive media3. When it is read from the media4. As it passes back through intermediate devices (RAID Controllers)5. When it arrives at the computer system

Integration EDP allows integration of hardware and software from multiple vendors. As a standard feature, all devices use the same rules for interpreting the protection information. There is no need to customize controllers, drives or software to support proprietary checking information.

Whitepaper | April 2008ComputerData is checked as it flows through the storage systemRAID ControllerDrive MediaFigure 1. End-to-end means data protection information stays with the data from the computer to the hard drive media and back so errors can be isolated to a component when they occur. End-to-end Data Protection | 2

Protection Three WaysThe protection is provided by eight bytes of data appended to each user data block. The eight bytes are divided into three fields (Figure 2), the Guard, the Ref-erence Tag and the Application Tag. The protection data is created by computer systems, transmitted with the user data block, and written to the drive media.

GuardThe Guard field protects against errors in the data. The two-byte Guard is a Cyclic Redundancy Check (CRC) on the data in the data block. This allows each device along the path from the computer system to the drive to check that the data in the block is still correct. Computer systems use the CRC algorithm specified by the protection specification to fill the Guard when sending a write data command. Because a standard CRC algorithm is used, hard drives can check that the data is correct before writing it to the media. On a read command, the drive reads the protection information from the media, checks it, and then sends the protection information along with the data. When a block of data is received by the computer system, the user data block is checked against Guard to verify that the data was received correctly.

Reference TagThe four-byte Reference Tag contains block address information. As data is moved from computer to drive media and back, perhaps through intermediate devices, such as a RAID controllers, there is a possibility of an addressing error. An addressing error causes the wrong blocks of correct data to be sent, or blocks to be sent in the wrong order. The Reference Tag numbers the blocks so hard drives and computer systems can check to see that the correct data blocks are received in the proper order.

相关文档
最新文档