omron 二维码阅读器v400_h

合集下载

欧洲OMRON工业自动化产品说明书

欧洲OMRON工业自动化产品说明书

Industrial AutomationSysmac NJ5 CPU, 20 mB memory, built-in EtherCAT (16 servo axes, in total 192 EtherCAT nodes) and EtherNet/IPController functionality Motion control, OPC-UA, Sequence control Max. number of synchronous axes16Max. number of axes (incl. virtual)16Max. number of robots0Primary task cycle time0.5 msProgram memory20 MBVariables memory 6 MBCommunication port(s)EtherCAT Master, EtherNet/IP, USBCommunication option(s)CAN, CompoNet Master, DeviceNet Master, DeviceNet Slave, EtherCAT Slave, MODBUS Master, MODBUS Slave, PROFIBUS DP Master, PROFIBUS DP Slave, PROFINET Master, Serial RS-232C, Serial RS-422, Serial RS-485Max. number of remote I/O nodes192I/O system CJ I/O Bus Max. number of expansion units40 Height90 mm Width90 mm Depth90 mm Weight550 gGX-JC033-port EtherCAT Junction module, 24 VDC power supplyGX-JC066-port EtherCAT Junction module, 24 VDC power supplyGX-JC06-H6-port EtherCAT Junction module, 24 VDC power supply, with node switchesHMC-SD492 4 GB SD memory cardNJ-PA3001Sysmac NJ power supply unit, 100-240 VAC, 30 W, "RUN" output relayNJ-PD3001Sysmac NJ power supply unit, 24 VDC, 30 W, "RUN" output relayW4S1-05D 5-port enhanced Ethernet switchCJ1W-BAT01Battery for CJ1M PLCsCJ1W-TER01End plate for CJ1 CPU rack or expansion rack. Only required as spare part.FDK CR14250SE Battery Safety DatasheetEN PDF 147 KBNJ-Series DatasheetEN PDF 3.05 MBNJ-Series CPU Unit Hardware Users ManualENPDF 6.95 MBNJ-series -[DeviceNet]-3G3MX2-series Inverter Connection GuideENZIP 2.98 MBNJ-series -[DeviceNet]-3G3RX-V1-series InverterConnection GuideENZIP 3.75 MBNJ-series -[DeviceNet]-ABB IRC5 Robot Controller Connection GuideEN ZIP 5.81 MBNJ-series -[DeviceNet]-NE1A-series Safety Network Controller Connection GuideENPDF 3.47 MBNJ-series -[EtherCAT]-3G3MX2-series Inverter Connection GuideENPDF 1.72 MBNJ-series -[EtherCAT]-3G3MX2-series Type V1Connection GuideENPDF 2.18 MBNJ-series -[EtherCAT]-3G3RX-V1-series InverterConnection GuideENPDF 2.28 MBNJ-series -[EtherCAT]-Balluff BNI ECT-508Connection GuideENPDF 1.85 MBNJ-series -[EtherCAT]-Balluff RFID (BIS V Series)Connection GuideENPDF 1.76 MBNJ-series -[EtherCAT]-CKD MW4G-seriesNW4Gx-T7ECxxx (W4G-OPP8-xEC-xx)Connection GuideEN PDF 1.2 MBNJ-series -[EtherCAT]-Copley Accelnet Connection GuideENZIP 5.75 MBNJ-series -[EtherCAT]-Copley Xenus Plus XEL Connection GuideENZIP 3.81 MBNJ-series -[EtherCAT]-DELTA ELECTRONICS ASDA-A2-series Connection GuideEN ZIP 3.72 MBNJ-series -[EtherCAT]-DELTA R1-EC-series Slave Remote Module Connection GuideENPDF 2.22 MBNJ-series -[EtherCAT]-DENSO WAVE RC8Robot Controller Connection GuideENPDF 3.54 MBNJ-series -[EtherCAT]-E3NW-ECT DigitalSensor Communication UnitConnection GuideEN PDF 2.01 MBNJ-series -[EtherCAT]-E3X-ECTConnection GuideENPDF 2.41 MBNJ-series -[EtherCAT]-Elmo Gold Solo Whistle Digital Servo Drive Connection GuideEN ZIP 3.49 MBNJ-series -[EtherCAT]-FANUC R-30iB Robot Controller Connection GuideENPDF 3.82 MBNJ-series -[EtherCAT]-FESTO CPX-FB38 Valve Terminals MPA Connection GuideENPDF 2.47 MBNJ-series -[EtherCAT]-FESTO CTEU-EC Valve Terminals VTUB-12Connection GuideENPDF 2.52 MBNJ-series -[EtherCAT]-FESTO Valve Terminals MPA CPX-FB37Connection GuideENPDF 2.01 MBNJ-series -[EtherCAT]-FH-series Vision System Connection GuideENPDF 2.38 MBNJ-series -[EtherCAT]-FQ-MS12x(-M)-ECT Vision Sensor Connection GuideENPDF 2.63 MBNJ-series -[EtherCAT]-GRT1-ECT SmartSlice Connection GuideENPDF 2.9 MBNJ-series -[EtherCAT]-GX-ILM08C -[IO-Link]-Balluff Cylinder Sensor (BMF 203K)Connection GuideEN PDF 2.24 MBNJ-series -[EtherCAT]-GX-ILMxxx -[IO-Link]-E2E-series Proximity SensorConnection GuideEN PDF 2.31 MBNJ-series -[EtherCAT]-GX-ILMxxx -[IO-Link]-E3Z-series Photoelectric SensorConnection GuideEN PDF 2.24 MBNJ-series -[EtherCAT]-GX-series Analog I/O TerminalConnection GuideENPDF 1.74 MBNJ-series -[EtherCAT]-GX-series Digital I/O TerminalConnection GuideENPDF 1.74 MBNJ-series -[EtherCAT]-GX-series Encoder Input TerminalConnection GuideENPDF 1.75 MBNJ-series -[EtherCAT]-HENGSTLER ACURO(R)AC58-series Absolute EncoderConnection GuideENPDF 1.47 MBNJ-series -[EtherCAT]-HIWIN D1-N-series Connection GuideENZIP 3.85 MBNJ-series -[EtherCAT]-HMS Anybus Communicator Connection GuideENPDF 1.93 MBNJ-series -[EtherCAT]-HMS Anybus X-gateway Connection GuideENPDF 3.16 MBNJ-series -[EtherCAT]-HORIBA STEC SEC-Z500X-series Mass Flow ControllerConnection GuideEN PDF 1.5 MBNJ-series -[EtherCAT]-Hivertec HES-C400/NJ Connection GuideENPDF 2.14 MBNJ-series -[EtherCAT]-Hivertec HES-M4xx/NJ Connection GuideENPDF 1.89 MBNJ-series -[EtherCAT]-IAI ACON/ACON-CA/PCON/PCON-CA/DCON-CA ControllerConnection GuideEN PDF 1.38 MBNJ-series -[EtherCAT]-IAI Corporation MSCON Controller Connection GuideENPDF 2.88 MBNJ-series -[EtherCAT]-IAI Corporation MSEP Controller Connection GuideENPDF 1.48 MBNJ-series -[EtherCAT]-IAI SCON-CA/SCON-CAL Controller Connection GuideENPDF 2.12 MBNJ-series -[EtherCAT]-IAI X-SEL Controller XSEL-R/S/RX/SX/RXD/SXDConnection GuideEN PDF 2.67 MB NJ-series -[EtherCAT]-KYOWA SENERGYController (MotionLinxSeries)Connection GuideEN PDF 1.72 MBNJ-series -[EtherCAT]-M-System R30-seriesRemote I/OConnection GuideENPDF 1.74 MBNJ-series -[EtherCAT]-M-System R8-seriesRemote I/OConnection GuideENPDF 2.19 MBNJ-series -[EtherCAT]-MTS KG R-series LinearPosition SensorsConnection GuideENPDF 2.46 MBNJ-series -[EtherCAT]-NX-ECC + NX-ILM400 -[IO-Link]- E2E-seriesProximity SensorConnection GuideEN PDF 2.44 MBNJ-series -[EtherCAT]-NX-ECC + NX-ILM400 -[IO-Link]- E3Z-seriesPhotoelectric SensorConnection GuideEN PDF 2.5 MBNJ-series -[EtherCAT]-NX-ECC + NX-ILM400 -[IO-Link]- FESTO SFAW-series W Flow SensorConnection GuideEN PDF 2.62 MBNJ-series -[EtherCAT]-NX-ECC + NX-ILM400 -[IO-Link]- FESTO SPAE-Pressure SensorConnection GuideEN PDF 2.42 MBNJ-series -[EtherCAT]-NX-ECC + NX-ILM400 -[IO-Link]- FESTO VPPM-seriesConnection GuideENPDF 2.35 MBNJ-series -[EtherCAT]-NX-ECC + NX-ILM400 -[IO-Link]- Piab ABVac.EjectorpiCOMPACT23Connection GuideEN PDF 2.68 MBNJ-series -[EtherCAT]-NX-ECC + NX-ILM400 -[IO-Link]- Turck I/O Hub(TBIL)Connection GuideEN PDF 2.76 MBNJ-series -[EtherCAT]-NX-PG0122 -[Pulse]-ORIENTAL MOTOR RK IIStepping MotorConnection GuideEN ZIP 6.11 MBNJ-series -[EtherCAT]-NX-PG0122 -[Pulse]-ORIENTAL MOTORStepping Motor αSTEPConnection GuideEN ZIP 8.5 MBNJ-series -[EtherCAT]-ORIENTAL MOTORNETC01-ECT NetworkConverterConnection GuideEN PDF 2.96 MBNJ-series -[EtherCAT]-ORIENTAL MOTORaSTEP DC Multi-AxisDrive (AZDxA-KED)Connection GuideEN PDF 3.99 MBNJ-series -[EtherCAT]-PHOENIX CONTACTAXL E ECx Axioline EConnection GuideEN PDF 2.71 MBNJ-series -[EtherCAT]-PHOENIX CONTACTAxioline F-series I/OsystemConnection GuideEN PDF 2.07 MBNJ-series -[EtherCAT]-SANYO DENKISANMOTION R TYPE SConnection GuideEN ZIP 4.28 MBNJ-series -[EtherCAT]-SMC EX180-SEC5-X23xSI UnitConnection GuideEN PDF 2.04 MBNJ-series -[EtherCAT]-SMC EX260-SECx SIUnitConnection GuideEN PDF 2.14 MBNJ-series -[EtherCAT]-SMC EX600-SECx SIUnitConnection GuideENPDF 2.62 MBNJ-series -[EtherCAT]-SMC IN587 SI unitConnection GuideENPDF 2.27 MBNJ-series -[EtherCAT]-SMC JXCE1 Direct inputtype Step MotorControllerConnection GuideEN PDF 1.59 MBNJ-series -[EtherCAT]-THK Network Unit TNU-EC Electrical Actuator Controller Connection GuideEN PDF 2.28 MBNJ-series -[EtherCAT]-Turck BL20-E-GW-EC GatewayConnection GuideENPDF 2.13 MBNJ-series -[EtherCAT]-VAT612/615/642/650/652/951/952/62/67Control ValveConnection GuideEN PDF 2.91 MBNJ-series -[EtherCAT]-WAGO I/O-SYSTEM 750-series Fieldbus Coupler Connection GuideENPDF 2.55 MBNJ-series -[EtherCAT]-YASKAWA Σ-V-series SGDV-xxxxE1Connection GuideEN ZIP 6.95 MBNJ-series -[EtherCAT]-ZW-7000-seriesDisplacement Sensor Connection GuideENPDF 2.11 MBNJ-series -[EtherCAT]-ZW-CE1 Displacement SensorConnection GuideENPDF 1.98 MBNJ-series -[EtherNet/IP]-ABB IRC5 Robot Controller Connection GuideEN ZIP 6.44 MBNJ-series -[EtherNet/IP]-CJ2-series Controller Connection GuideENZIP 6.41 MBNJ-series -[EtherNet/IP]-CK3M-CPU1x1Connection GuideENPDF 3.93 MBNJ-series -[EtherNet/IP]-DENSO WAVE RC7M Robot Controller Connection GuideEN ZIP 3.83 MBNJ-series -[EtherNet/IP]-DENSO WAVE RC8Robot Controller Connection GuideEN ZIP 5.39 MBNJ-series -[EtherNet/IP]-FH-series Vision System Connection GuideENZIP 1.96 MBNJ-series -[EtherNet/IP]-FQ2-series Smart CameraConnection GuideEN ZIP 3.55 MBNJ-series -[EtherNet/IP]-FZ4-series Vision SensorConnection GuideENZIP 1.74 MBNJ-series -[EtherNet/IP]-FZ5-series Vision SystemConnection GuideEN ZIP 1.93 MBNJ-series -[EtherNet/IP]-IAI CorporationACON/PCON/DCON/SCON Controller Connection GuideEN ZIP 2.73 MBNJ-series -[EtherNet/IP]-IAI Corporation XSEL-Rx/Sx ControllerConnection GuideEN ZIP 4.93 MBNJ-series -[EtherNet/IP]-Nidec Sankyo SC5000-seriesConnection GuideENZIP 7.36 MBNJ-series -[EtherNet/IP]-Omron Adept Robot ePLCConnection GuideENZIP 2.47 MBNJ-series -[EtherNet/IP]-Omron Adept Robot ePLCIOConnection GuideEN ZIP 2.6 MBNJ-series -[EtherNet/IP]-PHOENIX CONTACT AXL E-series I/O DeviceConnection GuideEN ZIP 2.22 MBNJ-series -[EtherNet/IP]-SMC EX600-SENx SI UnitConnection GuideEN ZIP 2.59 MBNJ-series -[EtherNet/IP]-SMC JXC91 Step Motor ControllerConnection GuideEN PDF 2.1 MBNJ-series -[EtherNet/IP]-Seiko Epson RC180 Robot Controller Connection GuideENZIP 2.6 MB NJ-series -[EtherNet/IP]-Turck BL20-E-GW-ENMultiprotocol GatewayConnection GuideEN ZIP 2.21 MBNJ-series -[EtherNet/IP]-Turck TBEN-seriesCompact Block I/O-moduleConnection GuideENZIP 1.57 MBNJ-series -[EtherNet/IP]-V680S-series RFIDConnection GuideEN ZIP 2.28 MBNJ-series -[EtherNet/IP]-WAGO I/O-SYSTEM 750-series Ethernet FieldbusCouplerConnection GuideEN ZIP 2.44 MBNJ-series -[EtherNet/IP]-Yamaha Motor RCX-series Robot ControllerConnection GuideEN ZIP 3.98 MBNJ-series -[EtherNet/IP]-Yamaha Motor TS-seriesSingle-axis RobotControllerConnection GuideEN ZIP 5.84 MBNJ-series -[EtherNet/IP]-Yamaha RCX340 RobotControllerConnection GuideEN ZIP 4.75 MBNJ-series -[EtherNet/IP]-ZW-7000-seriesDisplacement SensorConnection GuideEN ZIP 2.52 MBNJ-series -[EtherNet/IP]-ZW-CE1 DisplacementSensorConnection GuideEN ZIP 4.26 MBNJ-series -[EthernetTCP/IP]- FQ-CR-seriesConnection GuideEN ZIP 3.11 MBNJ-series -[EthernetTCP/IP]- Janome SewingMachine JR3000-seriesRobotConnection GuideEN ZIP 1.85 MBNJ-series -[EthernetTCP/IP]- MARS TOHKEN2D Image Reader (MVF-300/500 Series)Connection GuideEN PDF 2.05 MBNJ-series -[EthernetTCP/IP]- SCHOTTMORITEX MLEF-seriesDigital ControllerConnection GuideEN ZIP 2.75 MBNJ-series -[EthernetTCP/IP]- V750-seriesRFID SystemConnection GuideEN ZIP 4.7 MBNJ-series -[EthernetTCP/IP]- ZW-seriesDisplacement SensorConnection GuideEN ZIP 4.35 MBNJ-series -[RS-232C]-G9SP Safety ControllerConnection GuideEN ZIP 4.5 MBNJ-series -[RS-232C]-V400-R2-series UltraSmall Multi-code ReaderConnection GuideEN ZIP 4.64 MBNJ-series -[RS-232C]-V500-R2-series FixedLaser-Type BarcodeReaderConnection GuideEN ZIP 4.71 MBNJ-series -[RS-232C]-V750-series RFIDSystemConnection GuideEN ZIP 5.11 MBNJ-series -[RS-232C]-ZW-series DisplacementSensorConnection GuideEN ZIP 4.68 MBNJ-series -[RS-485CompoWay/F]-E5CC/E5EC/E5ACDigital ControllerConnection GuideEN ZIP 4.71 MBNJ-series -[RS-485CompoWay/F]-KM1/KE1-seriesConnection GuideEN ZIP 5.4 MBNJ-series -[RS-485Modbus]- ORIENTALMOTOR BLE-seriesBrushless MotorConnection GuideEN ZIP 2.67 MBNJ-series -[RS-485 Modbus]- ORIENTAL MOTOR RK II-series Stepping MotorConnection GuideEN ZIP 5.5 MB NJ-series -[RS-485Modbus]- ORIENTALMOTOR αSTEP AR-seriesConnection GuideEN ZIP 2.83 MBNJ-series -[RS-485Modbus]- ORIENTALMOTOR αSTEP AZ-seriesConnection GuideEN ZIP 3.01 MBNJ/NX SeriesBrochureEN PDF 6.96 MBNJ/NX-Series CPU UnitBuilt-in EtherCAT PortUsers ManualENPDF 16.3 MBNJ/NX-Series CPU UnitBuilt-in EtherNet/IP PortUsers ManualEN PDF 13.4 MBNJ/NX-Series CPU UnitMotion ControlUsers ManualEN PDF 20 MBNJ/NX-Series CPU UnitSoftwareUsers ManualENPDF 22.3 MBNJ/NX-SeriesInstructionsReference ManualENPDF 16 MBNJ/NX-Series MotionControl InstructionsReference ManualENPDF 4.93 MBNJ/NX-Series OPC UACPU UnitsUsers ManualENPDF 3.73 MBNJ/NX-SeriesTroubleshooting ManualUsers ManualENPDF 16.4 MBNJ/NX-Series for MotionControlGetting Started GuideENPDF 18.1 MBNJ/NX-series -[EtherCAT]- CKDABSODEX driver(AX9000TS/TH-U5)Connection GuideEN PDF 1.73 MBNJ/NX-series -[EtherCAT]- HitachiADV-Series AC ServoDrivesConnection GuideEN ZIP 4.29 MBNJ/NX-series -[EtherCAT]- Inficongauge (BPG402-SE)Connection GuideEN PDF 1.22 MBNJ/NX-series -[EtherCAT]- KashiyamaDry Vacuum Pump (E-CAT01 1ch)Connection GuideENPDF 1.59 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-CKD Sensor (PPXseries)Connection GuideEN PDF 2.43 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-CKD Sensor (WFCseries)Connection GuideEN PDF 2.75 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-CKD WFK2 Flow sensorConnection GuideEN PDF 2.09 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-MTS Sensors (E-Series)Connection GuideEN PDF 2.4 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-PATLITE Beacon (NE-IL)Connection GuideEN PDF 2.02 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-PATLITE Tower (LR6-IL)Connection GuideEN PDF 2.08 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-SMC (ISA3-xxx)Connection GuideEN PDF 2.61 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-SMC (xSE20Bx-L(-M/-P)-x)Connection GuideEN PDF 2.13 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-SMC ITVx000/-IO*Connection GuideEN PDF 1.89 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-SMC Servo 24VDC(JXCL1)Connection GuideEN PDF 2.23 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-Schmalz Ejector (SCPSi)Connection GuideEN PDF 2.4 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-ifm (O5D10x/O5D15x)Connection GuideEN PDF 2.42 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-ifm (PN7x94)Connection GuideEN PDF 2.72 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-ifm (TN24xx)Connection GuideEN PDF 2.74 MBNJ/NX-series -[EtherCAT]- NX-ECC +NX-ILM400 -[IO-Link]-ifm TR7439 Pt100/1000Connection GuideEN PDF 2.43 MBNJ/NX-series -[EtherCAT]- NidecSankyo S-FLAG II SeriesAC Servo (DB6xx41)Connection GuideEN PDF 2.65 MBNJ/NX-series -[EtherCAT]- ORIENTAL MOTOR Stepper Motor(AZ-series)Connection GuideEN PDF 2.89 MBNJ/NX-series -[EtherCAT]- SANYO DENKI AC ServoSANMOTION R 3E MODEL TYPE SConnection GuideEN PDF 3.08 MBNJ/NX-series -[EtherCAT]- SANYODENKI AC ServoSANMOTION RADVANCED MODEL TYPE FConnection GuideEN PDF 3.61 MBNJ/NX-series -[EtherCAT]- SHIMADZU Power Unit for TurboMolecular Pump (TMP)Connection GuideEN PDF 1.29 MBNJ/NX-series -[EtherCAT]- SICK Absolute Encoder (AFS60/AFM60)Connection GuideEN PDF 1.52 MBNJ/NX-series -[EtherCAT]- Schmalz Compact Terminal(SCTSi-ECT)Connection GuideEN PDF 1.33 MB NJ/NX-series -[EtherCAT]- WeidmüllerRemote I/O System (u-remote IP20)Connection GuideEN PDF 1.8 MBNJ/NX-series -[EtherCAT]- YASKAWA Σ-7-seriesConnection GuideEN ZIP 3.77 MBNJ/NX-series -[EtherNet/IP]- Balluff BNI EIP-50x-105-Z015Connection GuideEN PDF 3.35 MBNJ/NX-series -[EtherNet/IP]- CKD ABSODEX Driver (AX9000TS/TH-U6)Connection GuideEN PDF 1.71 MBNJ/NX-series -[EtherNet/IP]- HMSAnybus Communicator Connection GuideEN PDF 1.51 MBNJ/NX-series -[EtherNet/IP]- Hilscher netTAP NT100 Gateway (NT 100-RE-DN)Connection GuideEN PDF 3.5 MBNJ/NX-series -[EtherNet/IP]- IAI RCON system & MCON /MSCON / MSEP ControllerConnection GuideEN PDF 1.9 MBNJ/NX-series -[EtherNet/IP]- KOGANEI Manifold Solenoid Valve (F Series)Connection GuideEN PDF 2.43 MBNJ/NX-series -[EtherNet/IP]- Nordson ProBlue Adhesive MeltersConnection GuideEN PDF 2.61 MBNJ/NX-series -[EtherNet/IP]- ORIENTAL MOTOR αSTEP Compatible Driver (AZD-xEP)Connection GuideEN PDF 1.82 MB NJ/NX-series -[EtherNet/IP]- SMCSolenoid Valve (SI UnitEX260-SEN#)Connection GuideEN PDF 1.65 MBNJ/NX-series -[EtherNet/IP]- SchmalzK.K. Compact Terminal(SCTSi-EIP)Connection GuideEN PDF 1.69 MBNJ/NX-series -[EtherNet/IP]- ifm IO-Link master (AL1322)Connection GuideEN PDF 3.18 MBNJ/NX-series -[EtherNet/IP]- ifm IO-Link master (AL1920)Connection GuideENPDF 3.07 MBNJ/NX-seriesInstructions ReferenceReference ManualENPDF 67.9 MBNJ/NX-series MachineAutomation ControllerBrochureENPDF 1.95 MBNJ/NX-series MachineAutomation ControllerDatabase ConnectionCPU UnitBrochureEN PDF 1.24 MBNJ/NX/NY-seriesSysmac Library User’sManual for SafetySystem Monitor LibraryUsers ManualEN PDF 922 KBOmron GX-JC0x-xEtherCAT Junction BoxEtherCAT ESI fileENZIP 3.36 KBRedundancy and MotionSafetyFlyerENPDF 960 KBSysmacCatalogueEN PDF 43.5 MBSysmac CNCBrochureEN PDF 1.07 MBSysmac StudioOperation ManualEN PDF 65.9 MBSysmac: A FullyIntegrated PlatformBrochureENPDF 9.22 MB。

gfs4400中文说明书

gfs4400中文说明书

gfs4400中文说明书概述:Gryphon GFS4400 2D固定式二维影像条码扫描模块提供给用户一个完全独立的OEM使用解决方案,它易于集成到自助服务一体机、核价器、售票、文档处理和医学实验室应用,以及自助售货机和其他自动设备中。

易于集成的设计理念,让Gryphon GFS4400 2D扫描模块为系统设计者提供了一个‘即插即用’的解决方案。

采用抗高冲击树脂构造,经得起溶剂和消毒液反复清洗,同时密封外壳符合工业标准,防水防尘,提供可靠的扫描性能。

GFS4400 2D OEM扫描模块凭借出色的近距离扫描特性,广角视野,高移动耐受性,快速阅读,在解码以及读取受损条码方面为用户提供了卓越的性能。

与所有Gryphon扫描器相同,GFS4400扫描模块拥有Datalogic得利捷的‘绿点’技术,提供有效的读取反馈。

因为GFS4400 OEM扫描模块深红色的稳定照明光线,使得用户的使用舒适度更佳。

与竞争产品闪烁的光线相比,对眼睛来说更易分辨,同时高可见度的4点瞄准器定义了一个精确的阅读区域,可减少意外读取的次数。

瞄准器的中心十字在多条码的环境下,为目标条码进行了定位。

GFS4400 OEM扫描模块,针对类似邮政码、PDF417这样的堆叠码和复合码等的一维和二维条码,可提供快速读取性能。

对移动营销或票务应用而言,这款影像式扫描模块同样能在读取移动设备上的条码时表现出卓越的性能。

采集签名以及扫描文件需要单独设备来完成,但是有了GFS4400 OEM扫描模块之后,这些单独设备便不再需要了。

GFS4400 OEM扫描模块中有几种触发模式可供使用。

首先,该扫描模块可自动感测物体并自动触发。

还有一种连续扫描模式,可在条码通过其视野范围时自动扫描并传输数据。

另外也可以通过可编程序逻辑控制器(PLC)或从传感器外部远程触发。

GFS4400 OEM扫描模块有支持RS-232串口的GFS4450-9型号和支持USB接口的GFS4470型号。

Kobo Sage使用者指南说明书

Kobo Sage使用者指南说明书
關於 Kobo Stylus ........................................................................15
使用 Kobo Stylus 在螢幕上書寫和繪畫 .................................................15 更換 Kobo Stylus 電池 ...................................................................................17 使用手勢編輯手寫內容 ................................................................................. 18 使用 Kobo Sage 作為筆記本........................................................................22 使用 Kobo Stylus 在書上書寫備註...........................................................30 對 Kobo Stylus 進行故障排除.....................................................................32
在 eReader 上尋找書籍...........................................................48
關於「我的書籍」功能表 ............................................................................48 刪除書籍 ..............................................................................................................49

cx-one v4.0使用手册

cx-one v4.0使用手册

U


Ԏ᳡⬉ᴎ
598
᳔ᮄѻક䌘᭭䇋ⱏᔩ
FA整合工具包 CX-One Ver.4.0
新特性4
方便复用既存程序
数据结构
除了可用于管理具有同类型数据的数组之外, 在相同的结构中, 数据结构也可用于管理不同类型的数据。 此外, 该工具包通过数 据名称和类型而非I/O存储器地址管理数据结构。使用数据结构可 创建用于数据处理的既存程序, 从而实现轻松再用。
新特性1
᮴㒓䆒໛
ৃ㓪⿟ 㒜ッ
,7g䕃ӊ 㒘ӊ
ѻક㒘
智能输入功能可大幅减少输入程序的工作量
智能输入
提供包括指令和地址输入帮助、 地址递增以及地址增量复制功能 在内的全套直观编程功能。 以便让用户以最小的工作量实现高效的编程。
䕧ܹẃᔶ೒⿟ᑣⱘℹ偸
‫ޣ‬ᇥˁ
⊼˖Ϣ&;3URJUDPPHU9HUⳌ↨DŽ

& ;
2 Q H 9 H U
600
᳔ᮄѻક䌘᭭䇋ⱏᔩ
FA整合工具包 CX-One Ver.4.0
轻松编程CX-Programmer
来自列表的辅助位输入
可以从列表中选择辅助位中的时钟脉冲标志、 条件标志以及其他特殊位, 免去了记住地址的必要。
ৃ㓪⿟ ᥻ࠊ఼
໪ೈᎹ‫݋‬
ᣝ✻ᷛᖫⱘՓ⫼乥⥛ᥦ߫ˈ ᳔ᐌ⫼ⱘᷛᖫᰒ冫೼᳔Ϟᮍ
⦄എ㔥 㒰䆒໛
ⳕᏗ㒓ˋ ⳕᎹᯊ䆒໛
᮴㒓䆒໛
地址递增
下一操作数的地址(包括输入位和输出位)加1并作为默认显示。 这样可以轻松输入连续的地址。
ৃ㓪⿟ 㒜ッ ,7g䕃ӊ 㒘ӊ ѻક㒘
Ԏ᳡㋏㒳
ব乥఼
‫ࠡܜ‬䕧ܹⱘഄഔ &,2 Ӯ㞾ࡼࡴ ᑊ԰Ў咬䅸᪡԰᭄ᰒ冫DŽ

德国制造的4位数字数字显示压力传感器说明书

德国制造的4位数字数字显示压力传感器说明书

1:4-digit alphanumeric display 2:LEDs3:Programming buttonMade inGermanyProduct characteristics Combined pressure sensor ConnectorProcess connection:G 1A /Aseptoflex Vario Display units:bar,psi,MPa,%of the span Function programmable2-wire connection technology:analogue output3-wire connection technology:2outputsOUT1=switching outputOUT2=switching output or analogue output 4-digit alphanumeric displayMeasuring range:-1.00...10.00bar /-14.5...145.0psi /-0.100...1.000MPa Application Type of pressure:relative pressureHygienic systems,viscous media and liquids with suspended particlesLiquids and gasesApplication5MPa 725psi 50bar Pressure rating 15MPa 2175psi 150bar Bursting pressure min.5MPa725psi50barMAWP (for applications according to CRN)-25...125(145max.1h)Medium temperature [°C]Electrical data 2wires DC /3wires DC PNP/NPNElectrical design 20...32DC (2L)/18...32DC (3L)Operating voltage [V] 3.6...21(2L)/<45(3L)Current consumption [mA]>100(500V DC)Insulation resistance[MΩ]III Protection classyesReverse polarity protection Outputs 2-wire connection technology:analogue output3-wire connection technology:2outputsOUT1=switching outputOUT2=switching output or analogue outputOutput1x normally open /normally closed programmable +1x normally open /normallyclosed programmable or 1x analogue (4...20/20...4mA,scalable)Output function ---(2L)/250(3L)Current rating [mA]---(2L)/<2(3L)Voltage drop[V]pulsed Short-circuit protection yesOverload protection ---(2L)/125(3L)Switching frequency [Hz]I:4...20mA (Ineg:20...4mA)Analogue output 300(2L)/max.(Ub -10V)x 50(3L)Max.load[Ω]Measuring /setting range -0.100...1.000MPa -14.5...145.0psi -1.00...10.00bar Measuring range Setting range -0.098...1.000MPa -14.2...145.0psi -0.98...10.00bar Set point,SP -0.100...0.998MPa -14.5...144.7psi -1.00...9.98bar Reset point,rP-0.100...0.750MPa -14.5...108.7psi -1.00...7.50bar Analogue start point,ASP 0.150...1.000MPa21.8...145.0psi1.50...10.00barAnalogue end point,AEP 0.001MPa0.1psi0.01barin steps of SP1=2.50bar;rP1=2.30bar SP2=7.50bar;rP2=7.30bar ASP =0.00bar;AEP =10.00barFactory settingAccuracy /deviations Accuracy /deviations(in %of the span)Turn down 1:1<±0.2Switch point accuracy <±0.2Characteristics deviation *)<±0.15Linearity <±0.15Hysteresis <±0.1Repeatability **)<±0.1Long-term stability ***)Temperature coefficients (TEMPCO)in the temperature range 0...70°C (in %of the span per 10K)<±0.05Greatest TEMPCO of the zero point <±0.15Greatest TEMPCO of the span Reaction times 1(2L)/0.5(3L)Power-on delay time [s]---(2L)/3(3L)Min.response time switching output[ms]0.00...30.00Damping for the switching output (dAP)[s]0.01...99.99Damping for the analogue output (dAA)[s]45(2L)/7(3L)Step response time analogue output[ms]yesIntegrated watchdog Interfaces IO-Link Device COM2(38.4kBaud)Transfer type 1.0IO-Link revision 157d /00009D hIO-Link Device ID no profile Profiles yes SIO modeA Required master port type 1Process data analogue 2Process data binary 2.3Min.process cycle time [ms]Environment -25...80Ambient temperature [°C]-40...100Storage temperature [°C]IP 67/IP 68/IP 69KProtection Tests /approvals EMCDIN EN 61000-6-2DIN EN 61000-6-3Shock resistance 50g (11ms)DIN EN 60068-2-27:Vibration resistance 20g (10...2000Hz)DIN EN 60068-2-6:160MTTF[Years]Mechanical data G 1A /Aseptoflex VarioProcess connection ceramics (99.9%Al2O3);PTFE;stainless steel 316L /1.4435;surfacecharacteristics:Ra <0.4/Rz 4Materials (wetted parts)stainless steel 316L /1.4404;FPM;PTFE;PBT;PEI;PFAHousing materials 100million Switching cycles min.0.313Weight[kg]Displays /operating elements DisplayLED green Display unit LED yellowSwitching status 4-digit alphanumeric display Function display 4-digit alphanumeric displayMeasured values Electrical connection M12connector;Gold-plated contactsConnection Wiring1connection for2-wire operation2connection for3-wire operation3connection for IO-Link parameter setting(P=communication via IO-Link)RemarksRemarks(2L)=value for2-wire operation(3L)=value for3-wire operation*)linearity,incl.hysteresis and repeatability;(limit value setting to DIN16086)**)with temperature fluctuations<10K***)in%of the span per year1Pack quantity[piece]ifm electronic gmbh•Friedrichstraße1•45128Essen—We reserve the right to make technical alterations without prior notice.—GB—PI2794—16.04.2013。

Omron Microscan HAWK MV-4000智能相机配件清单说明书

Omron Microscan HAWK MV-4000智能相机配件清单说明书

Hardware RequiredStandard Ethernet ConfigurationNote: See page 5 of this document for a full list of available accessories, numbered to correspond with this table and the diagrams below.HAWK MV-4000 Smart CameraConfiguration Guide61-9000132-01CAMERA EndPOWER End1547621415Power Supply (12-Pin Socket)Ethernet Configuration with Flying Leads15462158M12 to Flying Leads Cable, 3 m – 61-9000151-01Pin Signal Wire Color 1Trigger White 2Power Brown 3Input 2Green 4Input 1Yellow 5Output 1Grey 6Output 3Pink 7Ground Blue 8Input Common Red 9NC Black 10NC Violet 11Output 2Grey-Striped Pink 12Output Common Red-Striped BlueEthernet Configuration with QX-1 and NERLITE Smart Series Illuminator10911131547621415Power Supply (12-Pin Socket)Photo SensorNERLITE Smart Series IlluminatorEthernet Configuration with Y Cable for Illuminator Control and Camera Power154762121415Power Supply (12-Pin Socket)NERLITE Smart Series IlluminatorNERLITE Smart Series IlluminatorNERLITE Smart Series IlluminatorHAWK MV-4000 AccessoriesElectrical SpecificationsHAWK MV-4000-03, -03C, -13, -13C, -20, -20C, -50, -50COperating Voltage for the HAWK MV-4000 under Testing Conditions 24V Rated Current600 mA Operating Voltage Tolerance±10%See the HAWK MV-4000 Smart Camera Guide for full electrical specifications.+10-28VTriggerGround Trigger/New Master / Input 1 CommonQX-1 Interface Device – for use with the HAWK MV-4000 (Top View)QX-1 Trigger Connector (T) 4-pin SocketConnector T on the QX-1 Interface Device is the trigger connector.Connectors 1, 2, and 3 can be used to bus power and data as required by the application.PTVGA/USB Connector M12 12-Pin Plug10/1000 Base-T Connector M12 8-Pin X-Coded SocketDigital I/O and Power ConnectorM12 12-Pin SocketOutput 3Power TriggerInput CommonInput 2Input 3Input 1Output 1GroundOutput 2Output CommonAnalog OutputHAWK MV-4000 Part Number Structure HAWK MV-4000 part numbers follow the format 8ABS-LFFA-LPPP.8 = HAWK MV-4000 Smart Camera(A) Enclosure0 = No Lens Cover1 = 50 mm Lens Cover2 = 70 mm Lens Cover(B) Software = 1 (Machine Vision)(S) Sensor Type1 = VGA, Mono2 = 1.3 Megapixel, Mono3 = 2 Megapixel, Mono4 =5 Megapixel, Mono5 = VGA, Color6 = 1.3 Megapixel, Color7 = 2 Megapixel, Color8 = 5 Megapixel, Color(L) Lens (See table below)0 = No Lens1 = 2/3” Standard Def.2 = 2/3” High Def.3 = 1” High Def.(FF) Lens Focal Length00 = No LensXX = Focal Length (mm) (See Lens table below.)(A) Accessories = 0(L) Lighting = 0(PPP) License100 = AutoVISION Sensor101 = AutoVISION102 = AutoVISION + Visionscape103 = AutoVISION + Verification104 = AutoVISION + Visionscape + Verification。

80pcs寺冈电子条码称操作步骤

80pcs寺冈电子条码称操作步骤

80pcs寺冈电子条码称操作步骤一、置141,142的步骤(一)设置141的步骤:用方式键选择到z模式下,按住置零键不放+141显示SP000;〔80L: 按住置零键不放+141显示SP000〕1、SP000〔条码格式〕:按4键—按*打印键显示SP001。

2、SP001〔条码方式〕:按1键—按*打印键—按3键—按x键显示SP003。

3、SP003〔标志位F1F2〕:按22键—按*打印键—按24键—按x键显示P024。

4、SP024〔条码缺省格式〕:按16键—按*打印键—42键—按X键显示SP0425、SP042〔是否承诺变价〕:按0键—按*打印键—按49键—按x键显示SP0496、SP049〔网络连接类型〕按2键—按*打印键—按50键—按x键显示SP0507、SP050〔客户服务机〕:按1键—按*打印键—按64键—按X键显示SP0648、SP064〔密码模式〕:按1键—按*打印键—按135键—按X键显示SP1359、SP135〔端口号〕按称号—按*打印键10、按项目键储存—按方式键两次退出。

〔80L:按M键两次退出〕(二)设置142的步骤:用方式键选择到Z模式下,按住置零键不放+3752后放开,再按置零键不放+142后放开显示SP600;〔80L:按住置零键不放+3752后放开,再按置零键不放+142后放开显示SP600〕1、SP600:按629键—按*打印键〔80L:按X键〕—显示SP626.2、SP629:按4键—按*打印键—按项目间储存—按方式键两次退出〔3:四设五入、4:保留分〕。

〔80L:按M M键两次退出〕3、SP628:按2键4、四次方式置零不放3752 置零不放142 628X 2 * 0 * 项目代码二、标签格式的设置步骤:(一)12X的设置〔30*37空白打印纸〕按方式键选择到S模式下:(80L:按M 键—按置零键—按M键—按12键—按X键—按1键—按*键〔显示Y_Cn_t〕)1、输入12—按*打印键—按1键—按*打印键—输入56—按*打印键—输入37—按*打印键三次,显示S 12.5 PIU.1F1EM;(80L:按去皮键—输入56—按*打印键—输入37—按*打印键—按0键〔显示P12.6no 1FrEE0〕)(二)、11X文本格式设置:按方式键选择在S模式下(80L: 按M 键—按置零键—按M键)1、按11键—按*打印键—按1键—按*打印键。

MicroHAWK V320-F多码读取器简介说明书

MicroHAWK V320-F多码读取器简介说明书

Compact barcode reader.•Simple configuration with WebLink. •5 megapixel sensor available.•Smallest in class.•IP40.•Single snap-in RJ50 connector and cable.•RS-232, Ethernet via USB.MicroHAWK V320-FOptics OptionsDirect Wiring OptionsAppearanceTypeModelDiffuser Kit – Peel and Stick Accessory. Exterior to unit.V330-AF1Polarizer Kit – Peel and Stick Accessory. Exterior to unit.V330-AF2AppearanceTypeLengthModelRJ50 to RS-232 and External PowerStraight2 Meters V320-WRX-2MRJ50 to RS-232 and External Power Right Angle2 Meters V320-WRXLR-2MPower Supply for V320-WRX-2M and V320-WRXLR-2M 2 Meters 97-9000006-01RJ50 to Flying Leads Straight3 Meters V320-W8-3MRJ50 to Flying Leads Right Angle to the Right *3 Meters V320-W8LR-3MV320-FWiring Options using V420-F Accessories*Right angle cables.AppearanceCategoryLengthModelAdapter V/F320-F to all V420-F Cable Accessories RJ50 to DB-151 Meter V320-WR-1MAdapter V/F320-F to all V420-F Cable Accessories Right Angle to the Right *RJ50 to DB-151 MeterV320-WRLR-1MUSB Breakout Cable 1 Meter V420-WUB-1MCable - USB Breakout With External Power Input 1 Meter V420-WUX-1M Power Supply2 Meters97-9000006-01Kit – Cable and Power Supply V420-AC1Cable – RS-232 Breakout (DB-15) and External Power Input 1 Meter V420-WRX-1M Power Supply2 Meters97-9000006-01Kit – Cable and Power Supply V420-AC0Cable – USB, IO, and Power Breakout 1 Meter V420-WU8X-1M Power Supply2 Meters97-000011-02Kit – Cable and Power Supply V420-AC2Cable – RS-232, USB, IO, and Power Breakout 1 Meter V420-WRU8X-1MPower Supply 2 Meters 97-000011-02Right angle to the rightV320-FV320-F Model Number StructureUse this legend when defining product part numbers. Please note that not all combinations of parameters are valid. For instance, fixed focus distance of 50 mm is not available with Narrow Lens. When ordering, use valid model numbers from the tables in the Ordering Information section only.V320-F [XXX][Y][ZZZ]-NN [P]Example Part Number:•V320-F050W03M-NNX: Fixed Focus at 50 mm, Wide Lens, 0.3 MP Monochrome, No Light, High Speed, X-ModeV320-F Valid Product MatrixV320-F Ordering InformationCategories:1.Fixed Focus Camerasa) V320 Monochrome and Color Fixed Focus Camera with Standard Lens b) V320 Monochrome and Color Fixed Focus Camera with Narrow Lens1a) V320 Mono and Color Camera with Standard Lens: Valid Combinations V320-F [XXX][Y][ZZZ]-NN [P]Key Classification Code MeaningXXXFocus Distance (mm)050Fixed Focus at 50 mm 064Fixed Focus at 64 mm 081Fixed Focus at 81 mm 102Fixed Focus at 102 mm 133Fixed Focus at 133 mm 190Fixed Focus at 190 mm 300Fixed Focus at 300 mmYLensW Wide Field of View - 5.2 mm Focal Length Lens M Medium Field of View – 7.7 mm Focal Length Lens NNarrow Field of View – 16 mm Focal Length Lens ZZZSensor03M 752 x 480 (0.3 MP) Pixel, Mono Sensor, Global Shutter 12M 1280 x 960 (1.2 MP) Pixel, Mono Sensor, Global Shutter 50C2592 x 1944 (5 MP) Pixel, Color Sensor, Rolling Shutter L Light Type N No Outer Light C Light Color N No Outer LightPSoftware LicenseP High Speed, Plus Mode XHigh Speed, X-ModeModelCategory Focus Type Sensor Lens Focus Distance (mm)Light License V320-FMonochromeFixed Focus 03M, 12M W, M 50, 64, 81, 102, 133, 190, 300None P, X Color Fixed Focus 50C W, M 50, 64, 81, 102, 133, 190, 300None P, X MonochromeFixed Focus 03M, 12M N 64, 81, 102, 133, 190, 300None P, X ColorFixed Focus50CN64, 81, 102, 133, 190, 300NoneP, XKey Classification Code MeaningXXXFocus Distance (mm)050Fixed Focus at 50 mm 064Fixed Focus at 64 mm 081Fixed Focus at 81 mm 102Fixed Focus at 102 mm 133Fixed Focus at 133 mm 190Fixed Focus at 190 mm 300Fixed Focus at 300 mmY Lens W Wide Field of View - 5.2 mm Focal Length Lens M Medium Field of View – 7.7 mm Focal Length Lens ZZZSensor03M 752 x 480 (0.3 MP) Pixel, Mono Sensor, Global Shutter 12M 1280 x 960 (1.2 MP) Pixel, Mono Sensor, Global Shutter 50C2592 x 1944 (5 MP) Pixel, Color Sensor, Rolling Shutter PSoftware LicenseP High Speed, Plus Mode XHigh Speed, X-ModeV320-F1b) V320 Mono and Color Camera with Narrow Lens: Valid CombinationsNote: 50 mm Fixed Focus option is not available with Narrow Lens.V320-F[XXX]N[ZZZ]-NN[P]Key Classification Code MeaningXXX Focus Distance (mm)064Fixed Focus at 64 mm081Fixed Focus at 81 mm102Fixed Focus at 102 mm133Fixed Focus at 133 mm190Fixed Focus at 190 mm300Fixed Focus at 300 mmZZZ Sensor03M752 x 480 (0.3 MP) Pixel, Mono Sensor, Global Shutter12M1280 x 960 (1.2 MP) Pixel, Mono Sensor, Global Shutter50C2592 x 1944 (5 MP) Pixel, Color Sensor, Rolling Shutter P Software License P High Speed, Plus ModeX High Speed, X-ModeV320-FRead RangesFixed Focus Field of View (mm) - Wide LensFixed Focus Field of View (mm) - Medium LensFixed Focus Field of View (mm) - Narrow Lens0.3 MP1.2 MP5 MPDistance (mm)Width Height Width Height Width Height 50493253395038646239664963478176498161785810295601017596721331217812997124921901711091821361741303002661702832132712024003532253762823592680.3 MP1.2 MP5 MPDistance (mm)Width Height Width Height Width Height 5034223627352664432745344332815334564254401026642705267501338454906786641901197612695121903001851181961471881404002451562601952491860.3 MP1.2 MP5 MPDistance (mm)Width Height Width Height Width Height 501510161216126419122115201581241525192418102301932243022133382440303929190543457435441300835389678563400111711188811384Read range specifications are subject to change.V320-FRatings and Specifications*1.These symbologies are supported based on Omron’s read capability validation standard. Omron recommends that validation be performed for each application.*2.Unless otherwise specified, reading performance is defined with center of field of view, angle R=∞.*3.*4.In an electrically noisy environment, use only the V430-F in combination with a noise filter cable (V430-W □F-□M) to ensure proper operation.V320-FV320-F □□□□03M-□□□V320-F □□□□12M-□□□V320-F □□□□50C-□□□Symbologies *11D SymbologiesCode 39, Code 128, BC412, Interleaved 2 of 5, UPC/EAN, Codabar, Code 93, Pharmacode, PLANET, Postnet, Japanese Post, Australian Post, Royal Mail, Intelligent Mail, KIX 2D Symbologies Data Matrix (ECC 0-200), QR Code, Micro QR Code, Aztec Code, DotCode Stacked SymbologiesPDF417, MicroPDF417, GS1 Databar (Composite and Stacked)Reading Performance *2Number of Reading Digits No Upper Limit (depending on bar width and reading distance)Aiming Light Two Blue LEDsIllumination Inner LEDs: Four White and Four Red (Wavelength: 625 nm)Outer LEDs:NoneOuter LEDs:NoneOuter LEDs:NoneReading Distance /Field of View Refer to Read Ranges section for detail.Pitch Angle (α) *3±30°Skew Angle (β) *3±30°Tilt Angle (γ) *3±180°Image CaptureFocus Fixed Focus (Wide = 5.2 mm, Medium = 7.7 mm, Narrow = 16 mm)Resolution752 (H) x 480 (V)1280 (H) x 960 (V)2592 (H) x 1944 (V)Color / Monochrome Monochrome CMOS Monochrome CMOS Color CMOS ShutterGlobal Shutter Global Shutter Rolling Shutter Frames per Second 60 fps42 fps5 fpsExposure50 to 100,000 μs Image Logging FTPTriggerExternal Trigger (Edge or Level), Communication Trigger (Ethernet, RS-232C)I/O Specifications Input Signals TriggerInput:5-28Vrated(0.16mA@5VDC);Default:3.3Vrated(********)Output Signals One Signal (Strobe): 5 V TTL-compatible, can sink 10 mA and source 10 mA Communication ConnectivityUSB 2.0 Full-Speed (Ethernet over USB and HID), RS-232Ethernet Specifications100BASE-TX / 10BASE-T Indicator LEDs PASS (Green), PWR (Green)Power Supply Voltage 5 VDC +/- 5%Current Consumption450 mA at 5 VDC (max.)Environmental Immunity *4Ambient Temperature RangeOperating: 0 to 40° C Storage: -50 to 75° C (No Icing or Condensation)Ambient Humidity RangeOperating and Storage: 5% to 95% (Non-Condensing)Ambient Atmosphere No Corrosive GasesVibration Resistance (Destructive)Oscillation Frequency: 10 to 150 Hz, Half Amplitude: 0.35 mm, Vibration Direction: X/Y/Z, Sweep Time: 8 minute/count, Sweep Count: 10 timesShock Resistance (Destructive)Impact Force: 150 m/s2, Test Direction: 6 directions, three times each (up/down, front/back, left/right)Degree of ProtectionIEC 60529 IP40Weight Main Body Only 59 gPackaging Weight Approx. 166 g (including packing)Dimensions Main Body Dimensions 52 (W) × 39 (D) × 24 (H) mm Packaging Dimensions 170 (W) × 117 (D) × 86 (H) mm AccessoriesReadMeFirst, CE Compliance Sheet LED Safety StandardIEC 62471-1: 2006 Risk-Exempt Group Safety StandardsEN 55024:2010, EN 55032:2015 + AC:2016FCC Part 15, Subpart B (Class B) UL60950-1BISRCM, KC, EAC and BSMI Pending Materials CaseAluminum Diecast, Alumite (Black)Reading Window Acrylic SoftwareWebLinkV320-F Dimensions (Unit: mm)V320-FDiffuser Kit – Peel and Stick Accessory. Exterior to unit. V330-AF1Polarizer Kit – Peel and Stick Accessory. Exterior to unit. V330-AF2V320-F RJ50 to RS-232 and External Power, Straight – 2 MetersV320-WRX-2MRJ50 to RS-232 and External Power, Right Angle – 2 MetersV320-WRXLR-2MPower Supply for V320-WRX-2M and V320-WRXLR-2M – 2 Meters97-9000006-01V320-FRJ50 to Flying Leads, Straight – 3 MetersV320-W8-3MRJ50 to Flying Leads, Right Angle to the Right– 3 MetersV320-W8LR-3MRight angle to the rightAdapter V/F320-F to all V420-F Cable Accessories, RJ50 to DB-15 – 1 Meter V320-WR-1MV320-F 11Adapter V/F320-F to all V420-F Cable Accessories, Right Angle to the Right, RJ50 to DB-15 – 1 MeterV320-WRLR-1MRight angle to the rightUSB Breakout Cable – 1 MeterV420-WUB-1MKit – USB Breakout Cable with External Power Input (1 Meter) and Power Supply (2 Meters)V420-AC1V320-F 12Kit – RS-232 Breakout Cable (DB-15) with External Power Input (1 Meter) and Power Supply (2 Meters)V420-AC0Kit – USB, IO, and Power Breakout Cable (1 Meters) and Power Supply (2 Meters)V420-AC2V320-F 13Related Manuals Man.No.Model Manual 84-9007234-02V320-F, V330-F, V420-F, V430-F MicroHAWK V320-F / V330-F / V420-F / V430-F User ManualCable – RS-232, USB, IO, and Power Breakout – 1 MeterV420-WRU8X-1MTerms and Conditions AgreementRead and understand this catalog.Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.Warranties.(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanshipfor a period of twelve months from the date of sale by Omron (or such other period expressed in writingby Omron). Omron disclaims all other warranties, express or implied.(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUTNON-INFRINGEMENT, MERCHANT ABILITY OR FITNESS FOR A P ARTICULAR PURPOSE OF THEPRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILLSUIT ABL Y MEET THE REQUIREMENTS OF THEIR INTENDED USE.Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) thenon-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty.See /global/ or contact your Omron representative for published information.Limitation on Liability; Etc.OMRON COMP ANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENT AL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.Suitability of Use.Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.NEVER USE THE PRODUCT FOR AN APPLICA TION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THA T THE OMRON PRODUCT(S) IS PROPERL Y RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.Programmable Products.Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.Performance Data.Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.Change in Specifications.Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product.Errors and Omissions.Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.Authorized Distributor:In the interest of product improvement, specifications are subject to change without notice.Cat. No. SP113A-EN-09190919 © OMRON Corporation 2019 All Rights Reserved.OMRON Corporation Industrial Automation CompanyOMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A.Tel: (1) 847-843-7900/Fax: (1) 847-843-7787Regional HeadquartersOMRON EUROPE B.V.Wegalaan 67-69, 2132 JD HoofddorpThe NetherlandsTel: (31)2356-81-300/Fax: (31)2356-81-388Contact: Kyoto, JAPAN OMRON ASIA PACIFIC PTE. LTD.No. 438A Alexandra Road # 05-05/08 (Lobby 2),Alexandra Technopark,Singapore 119967Tel: (65) 6835-3011/Fax: (65) 6835-2711OMRON (CHINA) CO., LTD.Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200· EtherNet/IP TM is a trademark of ODVA.· QR code is the registered trademark of DENSO WAVE.· Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. · The product photographs and figures that are used in this catalog may vary somewhat from the actual products.Note: Do not use this document to operate the Unit.。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

1240
相关信息
技术指南................................ 1298手册一览表............................ 1375标准认证机种一览表............. 1378EN/IEC 标准认证・适用型号一览表 (1384)
手持式二维码读码器
V400-H
最适合直接标志的便携式,简单、高性能
系统构成
与RS-232C 上位设备的连接与PC/PLC 连接
SYSMAC ㋏
˄RS-232C ッ 䖲 ˅
V400-H101V400-H201
PC
1241
二维码读码器 V400-H
种类
额定值/性能
名称
规格
型号 备注
通信I/F 视野二维码读码器RS-232C □5~10mm V400-H101二维码读码器
RS-232C
□15~30mm V400-H201
名称
规格
型号
备注
通信I/F
电缆长
通信电缆RS-232C 2m V400-W20-2M SYSMAC 系列连接用(带电源线)通信电缆RS-232C 2m V400-W21-2M DOS/V PC 连接用(带电源线)接触器————V400-AC1 定位用接触器(可以装卸)

——
——
V400-AS1
项目
型号
V400-H101
V400-H201
性能规格
视野
□5~10mm □15~30mm 最小单元尺寸70μm 200μm
读取距离(WD ) 40mm 照明
LED 控制
对应代码Data Matrix ECC200 10×10~64×64、8×18~16×48
QR Code (模式1、2) Version1~10读取方向360度 接口
RS-232C
输入(触发) 触发按钮(左右2个) 调试方法看LCD 画面进行/使用接触器
输出
工作指LED/LCD 显示(1.8英寸彩色液晶)/蜂鸣器一般规格
使用环境温度 0~40℃
使用环境湿度 35~85%RH (不结露) 保存环境温度-25~+60℃
保存环境湿度
35~85%RH (不结露)外形尺寸50×42×170(mm )保护结构 IP64(IEC 60529标准)
材质外壳:ABS 光学面:PC 显示面:PMMA 电源电压 DC5V ±10%(2m 电缆安装时) 消耗电流 1.0A 以下重量
约200g
1242
二维码读码器
V400-H
外形尺寸
(单位 :mm

二维码读码器V400-H101V400-H201
通信电缆
V400-W20-2M V400-W21-2M
1243
二维码读码器
V400-H

V400-AS1
接触器 V400-AC1。

相关文档
最新文档