拨 器说明书
国威WS848-P型电话交换器说明书

目录一、系统简介...................................................................................................................................................1.1概况.........................................................................................................................................................1.2主要功能.................................................................................................................................................二、产品规格...................................................................................................................................................三、结构和安装...............................................................................................................................................3.1外观说明.................................................................................................................................................3.2安装环境.................................................................................................................................................3.3接地法.....................................................................................................................................................四、一般功能编程举例………………………………………………………………………………4.1 怎能样开通或关闭外线…………………………………………………………………4.2怎样录制电脑话务员的语音…………………………………………………………………4.3怎样开通电脑话务员…………………………………………………………………4.4怎样设置外线打进指定分机响铃……………………………………………………………4.5怎样设置分机打出直拨外线或拨9打外线…………………………………………………4.6怎样设置外线打出专线专用…………………………………………………………………4.7怎样设置长途自动加发IP…………………………………………………………………4.8怎样设置自编分机号…………………………………………………………………五、系统编程...................................................................................................................................................5.2如进入编程状态5.2系统初始化 ............................................................................................................................................5.3外线开通与关闭设置............................................................................................................................5.4外线打入响应式选择............................................................................................................................5.5外线打入指定分机响铃设置...............................................................................................................5.6分机打出式设置....................................................................................................................................5.7分机外线打出权限设置.......................................................................................................................5.8分机允使用外线权限设置...................................................................................................................5.9分机国长途、声讯台及限制权限设置...............................................................................................5.10分机国际长途权限设置 .....................................................................................................................5.11分机外线通话时间设置 .....................................................................................................................5.12分机IP功能设置.................................................................................................................................5.13分机更改设置......................................................................................................................................5.14系统密码更改设置.............................................................................................................................5.15限制码设置..........................................................................................................................................5.16IP设置................................................................................................................................................5.17电脑话务员接通时间 .......................................................................................................................六、系统编程表...............................................................................................................................................七、功能使用表...............................................................................................................................................八、功能使用具体操作法 ..............................................................................................................................8.1呼叫线分机 ............................................................................................................................................8.2外线打出.................................................................................................................................................8.3指定外线打出 ........................................................................................................................................8.4外线打入响应 ........................................................................................................................................8.5日夜式选择 ............................................................................................................................................8.6外线转接.................................................................................................................................................8.7外线保留及取回 ...................................................................................................................................8.8遇忙转移及无人接转移........................................................................................................................8.9代接.........................................................................................................................................................8.10电脑话务员录制..................................................................................................................................一、系统简介1.1概况本集团是在综合国外众多集团优点的基础上开发出来的新一代通信设备,并按照中华人民国信息产业部技术要求生产。
TB6600升级版驱动器说明书最最新

TB6600升级版驱动器!安全注意事项一、简介TB6600升级版是一款适用于57/42型相电流4.0A以下两相混合式步进电机的驱动器,通过6位拨码开关设定7种细分(1/2A/2B/4/8/16/32)和8档输出电流(0.5A/1.0A/1.5A/2.0A/2.5A/2.8A/3.0A/3.5A)。
广泛用于各种中小型自动化设备和硬件,如:雕刻机、打标机、切割机、激光照排、绘图仪、数控机床、水晶打磨机、自动装配设备等。
最佳应用对象力矩1.8N.m及以下57步进电机,42步进电机。
产品特点※直流9-42V电源供电,12-30V供电最佳※控制信号输入电压3.3-24V通用(无需串电阻)※细分精度1-32细分可选※输出峰值电流4.0A※ H桥双极恒流驱动※输入信号高速光耦隔离※内置温度保护和过流保护※自动半流减少发热※电机噪声优化功能※体积小巧,节省空间电气参数输入电压 DC9-42V输入电流推荐使用开关电源功率5A输出电流0.5-4.0A最大功耗160W细分1,2/A,2/B,4,8,16,32温度工作温度-10~45℃;存放温度-40℃~70℃湿度不能结露,不能有水珠气体禁止有可燃气体和导电灰尘重量0.2千克输入输出端说明信号输入端PUL+:脉冲信号输入正。
PUL-:脉冲信号输入负。
DIR+:电机正、反转控制正。
DIR-:电机正、反转控制负。
ENA+:电机脱机控制正。
ENA-:电机脱机控制负。
◆电机绕组连接A+:连接电机绕组A+相。
A-:连接电机绕组A-相。
B+:连接电机绕组B+相。
B-:连接电机绕组B-相。
◆电源电压连接VCC:电源正端“+”GND:电源负端“-”注意:DC9-42V。
不可以超过此范围,否则会无法正常工作甚至损坏驱动器。
◆输入端接线说明输入信号共有三路,它们是:①步进脉冲信号PUL+,PUL-;②方向电平信号DIR,DIR-;③脱机信号ENA+,ENA-。
输入信号接口有两种接法,用户可根据需要采用共阳极接法或共阴极接法。
欧芯电子-DALI-P02触摸屏控制器说明书

DALI-PO2 (Product No.:402000030201)SummaryProduct FeatureDALI-P02 is one of our high-end, DALI walldim touch panel controller series, with characteristic of fashionable and beautiful appearance, complete functions, easy operations, sensitive key touch. The user can control DALI controller and driver to achieve group and scene control via this panel. It can be widely used in hotels, restaurants, villas, hospitals and offices and other regions.DALI-P02SignalIndicator lights Groups ScenesVoltage Current Dimension Packing size N.WG.W Working temp.Relative humidityDALI signal (Group/Scene/ broadcast )93416VDC±5%8mA86*86*10mm (L*W*H )145*135*48mm (L*W*H )100g 135g -10℃ ~ 60℃20~90% RHOthersModelOutputInputTechnical ParametersDimension (mm )1.ON/OFF2.GROUP DimmingFunction DescriptionMeet DALI Standard protocol IEC60929/IEC62386Supplied via DALI bus Support broadcast control.Support up to 3 groups control individually. Support up to 4 scenes control e blue led button indicator, easy to use.Can support many standard electrical wall box Glass panel, fashion style.Start Group and start Scene can be set by dip-switch in back side.Can choose white or black according to personal preference.In OFF status, long press the ON/OFF button to enable the panel, all the lamps will light up with the sceneALL: broadcast ,select all the lights connected in this DALI loop ,up to 64.When you want to select the broadcast command, press ALL and the corresponding indicator lights, you can choose the scene, or adjust the brightness by touch the ring with finger directly.If ALL is selected, the indicator lights, long press ALL, all the lamps will turn off.In ON status, long press the ON/OFF button to close the panel, and all the lamps will turn off. ON/OFF button led indicator will light weakly, indicate the ON/OFF switch position in darkness.GROUP 1: Select the start group, the “start group ID” can be set by dip-switch in backside.GROUP 2: Select the group which group ID is “start group ID +1” GROUP 3: Select the group which group ID is “start group ID +2”3.SCENEInterface IntroductionBinary dial table as following (0 means OFF, 1 means ON)4.Brightness adjust ringTouch the Scene 1/2/3/4 button, you can recall 4 kinds of scene configured by user.SCENE1:Recall the start scene, the “start scene ID” can be set by dip-switch in backside.SCENE2:Recall the scene which scene ID is “start scene ID +1” SCENE3:Recall the scene which scene ID is “start scene ID +2”SCENE4:Recall the scene which scene ID is “start scene ID +3”You can touch the ring to adjust brightness with finger. Clockwise turn will increase the brightness;Anti-clockwise turn will reduce the brightness. The lowest brightness is 1.5%, the maximum brightness is 100%.Start Group ID SettingsGroup DIP Switch: the start group ID setting, the ID is 0, 3, 6, 9, 12…..15.Start Scene ID SettingsScene DIP Switch: the start scene ID setting, the range is 0-15.Button Indicator SettingsUse the DIP switch 1 to set button indicator light. When set the DIP switch 1 to "ON", the button indicator will light up when touch the button; otherwise, the button lights are dark.Button Tone SettingsDALI DiagramUse the DIP switch 2 to set button tone. When set the DIP switch 1 to "ON", the button tone is enable; otherwise, the button tone is disable.Installation guide1.Mount an electrical box inside the wall2.To separate the glass panel and the back cover of the controller with a screwdriver along the gap of the back cover.3.Connect the wires4.To put the back cover on the electrical box and fix it with the screw.5.To buckle the glass panel to the bottom box.DALI-PO2(产品代码:402000030201)概述产品特点DALI-P02是欧切斯设计的高端DALI触摸式玻璃面板控制器系列的产品之一,它具有界面时尚美观,功能齐全,简单易用,按键触摸灵敏等特点。
世伟洛克 OG、1G和92系列 拨动开关阀 说明书

拨动开关阀 A-303A 拨动开关阀OG、1G 和 92 系列■手动和气动模式■直通型、角型和四通型阀体型式■阀体材料为 316 SS 和黄铜A-304 针形阀和计量阀A 特点■ 设计坚固、结构紧凑■ 启闭快速■ 孔径尺寸由 0.080 至 0.250 in. (2.0 至 6.4 mm)■ 流量系数 (C v) 由0.11 至 0.70■ 直通型、角型和四通流道型■ 气动执行■ 世伟洛克® (Swagelok®) 卡套管接头、内螺纹 NPT、外螺纹 NPT 及混合端接。
技术数据涂 PTFE 弹簧面板安装O 型圈阀杆密封、无需调节软阀座关闭123456结构材料测试每一世伟洛克拨动开关阀的阀座和密封在 200 psig (13.7 bar) 压力的氮气中测试过。
要求用检漏液检测、无泄漏。
清洁和包装每一世伟洛克拨动开关阀均按世伟洛克标准清洁和包装规范 (SC-10)、MS-06-62进行清洁和包装。
7P A-306 页气动执行机构介绍。
➀在填料螺母和弹簧之间有一个透明尼龙止推垫圈 (未标出)。
拨动开关阀 A-305A以 in. (mm) 所示尺寸仅供参考、可能有变动。
不锈钢阀选择一订购号.黄铜阀将 SS 改为 B 。
例:B -OGS2角型阀在订购号上添加 -A 。
例:SS-OGS2-A四通型阀可供应某些带有四通型阀体的拨动开关阀、这些阀能使流体在侧孔间连续流动、并能开通和切断通过底孔的流体。
有关详情、请与您当地授权的世伟洛克销售服务商联系。
TOGGLE VALVEW-ELD-137TOGGLE VALVE W-ELD-138订购信息和尺寸直通型阀角型阀A-306 针形阀和计量阀A执行机构最小压力、p s i g结构材料气动执行机构性能特点■ 阀与执行机构进行完全装配并经过工厂测试。
■ 阀杆可靠缩回不会滞留。
■ O 型圈阀杆密封、无需填料调节。
■ 执行机构端口可回转、使得机构安装方便。
TAC60I说明书 (1)

150- 150A AC
360 长×230 宽×220 厚
电流容量
200- 200A AC
360 长×230 宽×220 厚
(一般纯阻负载,阻值恒定)
260- 260A AC
350 长×255 宽×236 厚
外形尺寸 mm
300- 300A AC
425 长×254 宽×250 厚
400- 400A AC
475 长×325 宽×260 厚
500- 500A AC
475 长×325 宽×260 厚
600- 600A AC
475 长×485 宽×260 厚
800- 800A AC
458 长×500 宽×324 厚
1500- 1500A AC
540 长×584 宽×339 厚
过流报警
C 过流报警和限0% 50HZ
3 电流容量
20,50,80,100,150,200,260,300,400,500,600,800,1500A AC
控 制板电 源与 功 电源:380V AC ±10% 50HZ, 要求与负载电源同相位
4 耗
功耗:5W 最大
风扇电源
5
电压:220V AC 电流:0.5 A 以下
加电后,逐步增加控制输入信号或调整手动电位器,使负载电压从小到大逐步增加。若 发现异常,需停机检查。
三相负载连接形式
Y0- Y0:星型中心点接零 TR- Δ:三角型;或 Y:星型中心点不接零
20-
20A AC
203 长×143 宽×113 厚
50-
50A AC
227 长×158 宽×185 厚
80-
80A AC
227 长×158 宽×185 厚
ZZ-IO404D-RS485四路控制器说明书

ZZ-IO404D-RS485 四路控制器产品使用说明书目录一、产品特点 (3)二、产品功能 (3)三、产品选型 (3)四、主要参数 (3)五、接口说明 (4)六、接线说明 (5)1、RS485级联接线方式 (5)2、输出接线 (5)3、输入接线 (8)七、测试软件说明 (9)1、软件界面 (9)2、通讯测试 (9)八、参数及工作模式设置 (10)1、设备地址 (10)2、工作模式 (12)3、闪开闪断功能及设置 (13)九、开发资料说明 (14)1、通讯协议说明 (14)2、Modbus寄存器说明 (14)3、指令生成说明 (15)4、指令列表 (15)5、指令详解 (16)十、常见问题与解决方法 (19)十一、联系方式 (19)十二、质保售后 (19)十三、免责声明 (20)一、产品特点⚫DC7-30V;⚫继电器输出触点隔离;⚫通讯接口支持RS485;⚫通信波特率:2400,4800,9600,19200,38400(可以通过软件修改,默认9600);⚫通信协议:支持标准modbus RTU协议;⚫可以设置0-255个设备地址,5位地址拨码开关可以设置1-31地址码,大于31的可以通过软件设置;⚫具有闪开、闪断功能,可以在指令里边带参数、操作继电器开一段时间自动关闭;二、产品功能⚫四路继电器控制;⚫四路开关量输入;⚫支持电脑软件手动控制;⚫支持本机非锁联动模式;⚫支持本机自锁联动模式;三、产品选型型号modbus RS232 RS485 USB WiFi 继电器输入 ZZ-IO404D-RS485 ●● 4 4四、主要参数参数说明触点容量10A/30VDC 10A/250VAC耐久性10万次数据接口RS485额定电压DC 7-30V电源指示1路红色LED指示输出指示4路红色LED指示温度范围工业级,-20℃~85℃尺寸115*95*41mm重量330g默认通讯格式9600,n,8,1波特率2400,4800,9600,19200,38400软件支持配套配置软件、控制软件;支持各家组态软件;支持Labview等五、接口说明引脚说明:序号引脚说明1 + 电源正极2 - 电源负极3 VIN 无源输入时VIN和COM短接用,具体查看输入接线图4 COM+ 无源输入时VIN和COM短接用,具体查看输入接线图5 IN1 第一路开关量输入6 IN2 第二路开关量输入7 IN3 第三路开关量输入8 IN4 第四路开关量输入9 COM- 无源输入时使用,具体查看输入接线图10 常开第一路继电器输出常开端11 公共端第一路继电器输出公共端12 常闭第一路继电器输出常闭端13 常开第二路继电器输出常开端14 公共端第二路继电器输出公共端15 常闭第二路继电器输出常闭端16 常开第三路继电器输出常开端17 公共端第三路继电器输出公共端18 常闭第三路继电器输出常闭端19 常开第四路继电器输出常开端20 公共端第四路继电器输出公共端21 常闭第四路继电器输出常闭端六、接线说明1、RS485级联接线方式电脑自带的串口一般是RS232,需要配232-485转换器(工业环境建议使用有源带隔离的转换器),转换后RS485为A、B两线,A接板上A端子,B接板上B端子,485屏蔽可以接GND。
万能断路器说明书

智能型万能式断路器使用说明书1.概述适用范围HJW1系列空气断路器(以卜简称断路器)主要适用于交流50Hz,额定工作电压为400V、690V,额定电流为400A-6300A的配电网络中,用来分配电能和保护线路及电源设备免受过载、欠电压、短路取和接地等故障的危害。
断路器核心部件采用智能型控制器,具有精确的选择性保护,可避免不必要的停电,提高供电系统的可靠性、连续性和安全性。
型导及其舍义1 3正常的使用,安装和运输条件1.3.1正常使用条件a)周围空气温度上限不超U+40℃,下限不低于-5℃,24h的平均值不超过+35℃,注:在周围空气温度高于+40℃或低-5℃的条件下使用的断路器应与制造厂协商。
b)安装地点的海拔不超过2000m,c)大气的相对湿度在周围最高温度+40℃时不超过50%,在较低在温度下可以有较高的相对湿度(侧如20℃时的90%),并考虑到因温度变化发生在产品表面上的凝露。
1.3.2正常安装条件a)安装位置应垂直、各方向的倾斜度不超过5℃;b)污染等缎:3级c)安装类别:断路器主电路及欠电压脱扣器线圈、电源变压器初级线圈为Ⅳ级,辅助电路、控制电路为Ⅲ级。
1 3 3正常贮存和运输条件a)温度下限不低于-25℃,上限小超过十55℃,b)相对湿度(25℃时)不超过95%,c)产品在运输过程中,应轻搬轻放,小应倒放,应尽量避免剧烈碰撞。
2.技术特征21分类2.1.1按安装方式分:固定式、抽屉式。
2 1 2按操作方式分:电动操作、手动操作。
2 1 3按脱扣器种类:具有智能型控制器、欠电压瞬时(或延时)脱扣器和分励脱扣器。
2 1 4智能型控制器分娄:a) Perfection-L(简称L)型(经济型,光柱显示),h) Perfection-M(简称M)型(普通型,LED数码显示),c) Perfection-H (简称H)型(增强型,LCD液晶显示)。
主要技术参数见表1表1主要技术参数2 .3主要技术性能. l智能型控制器保护特性的电流整定值范围及准确度见表2。
tiger911拨号器说明书

tiger911拨号器说明书连接911设备1、接至DC12V电源:红色(+)、黑色(-)2、设定触发信号及电话系统。
设置J1、J2、J3跳线:J1:左边—TONE音频如使用电压输入:黄色(+)、绿色(-)J2—左边,J3—右边:电压输入。
将报警主机的报警输出正极端接Tiger911的黄色端。
电话线直接插到tiger911的电话输入端子即可。
进入编程输入:[P]+[密码911]+[Enter](默认密码为911)。
如密码输入正确,则显示一下O,然后进入编程状态显示S;如密码输入错误,则显示一下E,退回工作状态,可按上述步骤重新输入。
存储第一组电话号码例如电话号码为:62817323,操作步骤如下:1、在编程状态下,输入:[E1]-[62817323]-[Enter],键入Enter后开始存储电话号码。
如显示O,则表示正确存入;如显示E,则表示未能正确输入,用户可重新输入。
2、如要清除第1组电话号码,在编程状态下输入[E1]+[Enter]。
3、由总机自动拨分机(不用转接),例如分机为12,则输入:[E1]-[62817323]-P-12-[Enter] 每按一次P,即暂停2秒。
4、第2,3,4组电话号码设置方式同第1组设置。
查询电话号码在编程状态下,按[3]键,显示C(表示CHECK),再按查询之E1,E2,E3,E4或P。
输入:[3]+[E1](或E2,E3,E4,P)存储语音信息可存储20秒语音信息。
在编程状态下,1、直接录音。
按[1]键,显示R(表示RECORD)。
输入[1]+开始讲话,录音2、播放语音。
按[3],再按[2]键,显示P(表示PLAY)。
输入[3]+[2]+播放存储的20秒录音存储及查询密码1、存储密码:例如密码为714160(密码为0-6位)输入:[P]+714160+[Enter]2、查询密码:输入[3]+[P]3、按下[RESET]按钮,恢复默认密码911三种编程可选报警方式A、输入[5]+[0]+[enter]:报警信号一旦触发,则连续拨号3次,中间可用密码解除。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
AUTO-DIALER 911
微电脑自动求救机
CCTV SECURITY ALARM AUTOMATION SYSTEM
电气特性:
工作电压:DC11V TO 15V
静态电流:20mA (MAX)
拔号方式:音频/脉冲,跳线选择J1
报警方式:N.C.、N.O.和电压信号跳线选择J2、J3
录音时间:20秒,掉电后电话号码、语音不丢失
储存电话号码:4组电话,每组最长可存入16位数字
二级私密码:0-6位私人密码,前三位可用解除报警,整体(六体)密码用于更改设置出厂密码:911
外观图:
① 喇叭
② 麦克风
③ 7段显示器:输入所要储存之号码时,会同时显示其号码
④ E4指示灯:设定E4号码时,此灯会亮
⑤ E1指示灯:设定E1电话或行动电话号码时,此灯会亮
⑥ E2指示灯:设定E2电话或行动电话号码时,此灯会亮
⑦ E3指示灯:设定E3电话或行动电话号码时,此灯会亮
若设定密码时,E1、E2、E3及E4指示灯会亮
⑧ 接至电话接头
⑨○10 接至DC12V电源,桔色线(或红色)接正电压,咖啡色线(或黑色)接负电压 ○11○12 信号触发线,当接到N.C.或N.O.干接点时,不分极性,作为DC12V电压输入时,蓝
色线(或黄色)接正电压,绿色线接负电压
○13 P按键可作为以下用途:
可储存6位数字作为密码
当使用于语音自动回报系统之总机时,可作为暂停时间,按1次,两秒;按2次,4秒,以此类推.有此功能,即可自动打到分机
○14 接并联电话机
设定触发信号及电话系统:
①打开背盖
②可看见印刷电路板上有3个跳线座J1、J2、J3,依序并排。
可根据附图调整触发信号及电话系统
③ 配合电信局设定电话为TONE或PULSE系统
将J1设定于“左边”即为TONE系统
将J1设定于“右边”即为PULSE系统
④ 触发信号,请根据保全主机或感应器触发后输出接点,
选择适当之跳线座组合。
(A)N.C.输入:将J2置于“左边”,J3亦置于“左边”
(B)N.O.输入:将J2置于“右边”,J3置于“左边”
(C)电压输入:将J2置于“左边”,J3置于“右边”
⑤ 设定完成后,请将背盖盖上
微电脑自动求救机AUTO-DIALER操作程序
开机后先自检:
自检完毕后进入工作状态,七段显示器的右下角小数点闪烁,若已存有信息,则收到报警信号后AUTO-DIALER自动开始报警,如要设置或改变设置,按以下步骤可以储存,检查电话号码,密码及录音、放音
1 进入编程状态:
位)然后按下
注意:出厂密码为911
例如:新机器未更改密码时进入编程状态操作如下:
P ⑨ ① ① ENTER
如密码输入正确则显示一下 □ , 然后进入编程状态显示 5
若密码输入错误则显示一下 E ,退回工作状态,可按上述步骤重新输入
2 储存第1组电话号码:
在编程状态下,即显示 5 状态下:
例如电话号码为93953399,则操作程序如下:
A
9○3○5○3○3○99
□ ,则表示已正确存入, 然后返回 5 状态,如显示一下E ,则表示未能正确存入,
机器会返回 5 状态,用户可重新操作,如要清除第1组电话号码时,只需在 5 状态下
B 若先拨至语音自动播报总机,不透过接线员转接,再自动拨到分机,假设分机号码为
12,则储存方式如下:
9○3○5○3○3○99①②
C 每按一次
(储存第2、3、4组电话号码方式均与第1组相同)
3查询所预存之电话号码:
在编程状态下,即显示5状态下,按3键,此时显示匚,表示CHECK,再按所欲查询之E1、E2、E3、E4或PAUSE,显示器开始显示号码,其操作程序如下:
或或或显示器开始显示所预存之电
4储存及播放求救语音信息:
A 本机可储存20秒语音信息,在编程状态下,即5状态下,按1键(此时显示器显示┌
表示RECORD),即可直接录音,其操作程序如下:
①开始讲话,录音回音嘟响(20秒后录音完毕,即自动停止。
)
B播放求救语音信息:在编程状态下按3键再按2键,(此时显示器显示P ,表示PLAY),即播放录入之语音信息,其操作程序如下:
③②播放预存之20秒语音信息回音嘟响(20秒后,即自动停止)5储存密码及查询密码:
A 储存密码:
可储存(0-6位)私人密码,密码出厂时预设为911。
如私人密码为714160,则操作程序如下:
5 ⑦①④①⑥
0,即可听到回音嘟响声,表示输入完毕
B 查询密码:
在编程状态下,即 5 状态下,按3键,显示器显示密码,其操作程序如下:
键③显示密码,显示完毕后,即回音嘟响声
C如使用当中遗忘密码,则需打开背盖,加电到工作状态,按下(图一)所示的RESET 键,则密码恢复为出厂密码911
6三种编程可选择报警方式:
A 依次键入--5--0--enter:报警信号一旦触发,则连续拨号报警三个循环,中间可用密
码解除;详见第8条
B依次键入--5--1--enter:报警信息号一旦触发,则连续拨号报警一个循环,中间可
用密码解除;详见第8条
C 依次键入--5--2--enter:报警信号保持触发才拨号,一旦报警信号中断,拨号报警也立
刻停止
检查键入--3--5:对应A、B、C分别显示0、1、2
7停止求救拨号:
当AUTO-DIALER911被触发后,即根据原先储存之电话号码,拨号求救报警。
想要随时停止AUTO-DIALER拨号报警,可于显示器显示□时,输入私人密码,以停止拨号求救。
假设密码为1、2、3,当输入1 2 3时,显示器即由原来之显示□,改为显示1、2、3,如密码正确时,即发出嘟声解除报警。
解除报警,只需键入前碱闰密码即可,若密码不足三位,则需用“0”补齐
例如:密码为1、2,操作程序为:显示□状态下,键①② 0 即可
8注意事项:
A 以上设定操作时,若欲变更原设定内容,只需编程状态下,即5状态下,重新操作同
一步骤,即可自动储存新内容
B正确地按照说明书安装使用是十分重要的。
在我们的销售活动中,经常会遇到一些新客户在试用机器后说机器不正常,当我们的工程师赶赴现场后,才发现往往是客户电话线接错或者是跳线设置不对,以及报警方式没有设置。
所以我们针对这三点希望客户能够特别注意:
(1) 报警方式设置(详见使用说明书第6条)
(2) 报警线触发方式跳线设置(详见设定触发信号及电话系统)
(3) 电话线的连接(详见设定触发信号及电话系统)
C 常见故障排除法:
(1)触发但拨不出号码:可能是电话线接反
(2)不触发:可能触发方式设置错误,即J2、J3跳线设置错误
(3)放音时噪音大:大多是由于拨号器的电源有问题
(4)拨号不停:是没有选择设置报警方式
D 不需主机直接用拨号器的方法:
(1)选择对应的触发方式,911可直接接探头、门磁、紧急按钮、电源开关而形成独立的防盗系统
(2)布防:只需关掉电源,关门出去后,打开电源进入警戒状态
(3)撤防:在输入电话号码时,在电话号码前面按8次P,即可延时16秒,每按一次P可延时2秒,进门后在16秒内按密码解除报警或关掉电源。