莫顿智能照明产品手册
LB Management智能灯泡控制系统用户手册说明书

LB Management18CONTENTS The new LB Management 02Overview of the advantages 04In use: Single family house 06In use: Office building 08The controls 10The inserts 11Operation in switch design 12With the press of a button 14The Standard timer 16The Universal timer Bluetooth 20The Clever Config app 22Simply illuminating 24The automatic switches 26The motion and presence detector 28Dimming expertise 30LB Management workbook 3216 Timer with added convenience 26 Control light automatically 04An overview of all advantages22The Clever Config app 1The new LB ManagementThe installation is designed for tradespeople. For example, the small installation depth of only 24 mm (DALI insert 29 mm) creates more space for the wiring. A stable supporting plate in steel, the enclosed mounting claws and increased claw pull-out forces provide a firm hold and optimum alignment in the flush-wall box. In addition, satellites can be connected. Test operation at the site is also possible without a cover. The integrated test button, with which different operating modes can be set, shortens the installation time. The covers are simply pushed on with the help of stable retaining springs in stainless steel. During the installation, the integrated signalling by means of LED or display ensures that no unintended confusion occurs when allocating insert and cover.Out of the JUNG light and blinds management has come theLB Management. With the combination of different inserts andcovers, the modular system provides a solution for virtuallyevery desired function for light and shading control. Whenretrofitting installations, individual components (always insertplus cover) can also be exchanged for new ones from the LB Management and the others can continue to be used.Characteristics are the simple installation and commissioning, the possibility for retrofitting of existing installations andconvenient operation.Overview of the advantagesThe modular principle of the LB Management offers clearadvantages not only for tradespeople but also for ownersand modernisers.1 “Hands-free lighting” with automatic switches: practical and energy-saving 2Alarm function: blinking light for motion detection 3 Automatic light in the guest bathroom: no searching for the light switch 4 Lighting control with satellite unit: extension by operating element 5 Lock-out prevention: deactivation of the automatic shutter control at the press of a button 6 Shading complete areas: shutter control in groups by room, floor or house 7 Astro function: shade a living room with a timer and based on sun positionThe description of these scenarios, withcircuit diagrams and parts list can be foundIn use: Single familyIn private building, the LB Management provides more convenience and energy efficiency with control of light and shadingaccording to need. Daily routines are made easier with automaticfunctions. Individual settings and variable operating possibilities improve living quality.75443126666 76In use: Office buildingIn commercial construction such as office buildings, with the LB Management, the working conditions are optimised in a simple manner. Automatic functions provide more security and convenience here. With constant light regulation, the energy efficiency is increased in addition.1Daylight-linked lightingcontrol in the entrance area:safe and economical2Automatic stairwell light:automatic switches provide safety,also for retrofitting3In the meeting room: always theright light with light and shadingcontrol matched to your needs4Constant light function in the office:optimum illumination with a combinationof presence detectors and DALI push-button controls5Semi-automatic lighting with energy-saving function through appropriate delay times:ideal for small kitchens or server roomsThe description of these scenarios, withcircuit diagrams and parts list can be found532544431 2198STANDARD TIMER WITH DISPLAYThe Standard timer is a 1-channel timer for all inserts. The high-quality,real glass surface has an illuminated display and six sensor buttonsfor operation. The current time can be saved as the switching timeusing fast programming. The locking function deactivates automaticfunctions, satellites and timer programmes. Thanks to the astrofunction , switching times are adapted to the position of the sun.UNIVERSAL CENTRE PLATEThe Universal centre plate with memory and locking function is suit-able for almost all LB Management inserts. A coloured LED is assignedto each rocker half and is used for the function and status display.Opera t ion is performed manually or automatically. The cover forthe automatic shading control is available with appropriate arrow symbols.UNIVERSAL TIMER BLUETOOTHThe Universal timer Bluetooth is an attachment forall inserts for light and shading control. Operationcan be manual with the two rockers or with a smart-phone using the Clever Config app. Colour LEDs forthe display of functions and appropriate buttonprinting optimise operation.The controlsThe inserts LIGHT INSERTS BLIND INSERTS STANDARD CENTRE PLATEThe Standard centre plate is an attachment for all LB Managementinserts. Operation of light and shade is manual. The button can beactuated at the top, bottom and also full surface. The centre plateis available with or without symbols.11Operation in switch designThe controls in the LB Management are all available in the multifaceted JUNG design. As a result, they convince not only with their intuitive operating philosophy, but also with respect to form, colour and material.Without symbols for lighting control Left button without symbols for lighting control“Standard” and “Universal” centre plates, depending on the combined insert, light or shading is controlled manually with the press of a button. The universal design has additional convenience functions. For example, the upper right button (lock symbol) can activate the locking function for all automatic functions and the memory function. Alongside two switching times, a ventilation position for the shutter can also be stored. Thanks to appropriate symbols, operation is self-explanatory.With the press of a buttonThe Standard timerReal glass front in black or white with six sensor buttons forintuitive operation – these are the striking characteristics ofthe Standard timer with illuminated display. In this way, theautomatic control of light and shading becomes particularlyconvenient.SWITCHING TIMESThe Standard timer has two week blocks: fromMonday – Friday and from Saturday – Sunday.For both, time switching for light (4 times) or shade(2 times) can be programmed.ASTRO FUNCTIONThe astro function controls light and shadedepending on sunrise and sunset.SUMMER/WINTER CLOCK CHANGEThe change from summer to winter time and backis automatic. In the process, switching times arechanged accordingly.LOCK-OUT PREVENTIONProtection against being locked out: if the lockingfunction is activated, this is shown clearly on thedisplay .The display switches off automatically aftertwo minutes or a continuous display of thecurrent time is possible . The current time canbe saved as the switching time using fastprogramming . The next blind movementtime or switching time is shown on the display.The integrated Astro function, automaticsummer/winter clock change and a lockingfunction are also included.The Universal timer Bluetooth impresses above all with its operating concept. The opera t ion and parametrisation are carried out both mechanically with button presses and mobile with a smartphone with the Clever Config app. The combination with the brightness/temperature sensor allows auto m atic shade or light control based on sun position. With Bluetooth Low Energy, connecting and data transmission are parti-cularly convenient and secure.UNIVERSAL TIMER BLUETOOTHBrightness andtemperature sensorCREATING A CONNECTION Connecting the app with the LB Management device uses Bluetooth Low Energy. After a successful scan, the devices found are displayed in a clear list. The respective device configurations can then be transferred to the app.SIMPLE SET-UPThe connected devices can now be assigned to rooms and given a name, which simplifies allocation during opera t ion. In the “Parameters” menu point, the device settings can then be individualised as desired or simply copied from devices already stored.TIMER SETTINGAutomatically running timer pro-grammes: creating timer controls for the LB Management is as simple as the alarm on a smartphone. In this way, the respective device is switched on or off or switched to a different status, e. g. “Illumination dimmed 40 %”.ACCORDING TO SUN POSITION As well as programming by time, the sequences can also be set with the astro function dependent on the sun position. In the course of the year, the times for the blinds/shutters moving out and in, and the switching on and off of the light, adapt to the changing sunrise and sunset times.The Clever Config appMore information on the settings for the Clever Config app can be found in the LB Management workbook.MORE SECURITYDevice configuration and device pair-ing can be locked with a password and thus protected from unwanted access. The pairing mode can also be protected so that the device cannot be operated with the app by other people.OPERATION MADE EASYWith one finger tip, the lighting is switched on or off or the illumination is dimmed to the desired brightness. Blinds and shutters are moved out or in or into the desired position. Eventhe louvre angle can be simply set.2322Simply illuminatingLight according to your mood, light on demand – with the components of the LB Management you get more convenience and energy efficiency for your illumination control . Very easy with automatic switches, presence detectors and dimmers.The automatic switchesThe 180° detection range of the automatic switches is monitored by two PIR sensors that can be used individually or together. In the function as movement detector, they are ideal to use in corridors and passages. The 2.20 mversion can be used very well in offices or recreation rooms. The settings in the universal designs are conveniently made using the Clever Config app.Automatic LightThe automatic switches 1.10 m and 2.20 m for illumination control based on movement.Settings using Clever Config appEach of the three PIR sensors is allocated an individually activated area of 120° detection angle. By grouping up to five devices, the detec t ion area can be extended. In its role as a presence detector, the compact device auto m atically provides, for example, energy- saving lighting of the work area in an office. In corridors and hallways on the other hand, the motion detector demonstrates its strengths. The device has a 360° detection area with a radius of 20 metres – assuming an installation height of three metres. The device has a pres-ence, night light, alarm and hotel function as well as constant light control.You can rely on the detection characteristics of the motion/ presence detector. When installed at heights of up to six metres, the unit registers everything that is moving within a diameter of approx. 20 m. For this, the device has three PIR sensors operating independently of each other. All settings are made conveniently using the Clever Config app.Settings usingClever Config app29ROTARY DIMMER/POWER DALI POTENTIOMETER The Standard and Universal rotary dimmers work according to the leading edge phase control or trailing edge phase control principle. Setting the device to the dimming principle that matches the respective consumer is done automatically or also manually for the universal design. A coloured LED indicates the selected operating mode. The Power DALI potentio m eter insert operates lamps with DALI interface, including colour temperature control (tunable white).UNIVERSAL DIMMER FOR RAIL MOUNTING LED/ POWER AMPLIFIERThe dimmer version for the distribution also works according to the leading edge phase control or trailing edge phase control principle. The dimmer for rail mounting is operated via a 2-wire or 3-wire satellite unit or with a button with make contact. The power amplifier LED is used as a capacity expan s ion for spreading larger loads for the LB Management dimmers.MINI UNIVERSAL DIMMER LEDThe compact dimmer is suitable for installation in standard flush-mounting boxes. The operation of all common lamps is then carried out via a 2-wire satellite unit, rotary satellite unit or a button with make contact. The dimmer mini also uses the leading edge phase control or trailing edge phase control principle.LB Management workbookCONTROL VERSIONSThe various possibilities for controlling light and shade described in detail and clearly presented. Including use cases, concrete advantages and notes on connection versions.WIRING DIAGRAMSFrom simple installation of the individual components to complex installations with multiple satellite units or group switching, the descriptions in the work-book are always provided with concrete wiring diagrams.COMMISSIONINGCommissioning and parametrisation of the individual LB Management devices are also explained and illustrated. In this way, the installer can become familiar with the work in advance or also refer to specific areas on location at the site.The handbook for the electrical installer: With the LB Management workbook, the professional has all the information on the modular system in the hand. From the individual building blocks to functions and application examples to concrete wiring diagrams – all the valuable information in an overview.1710 DEStandard touch dimmer insert LED1711 DEUniversal touch dimmer insert LED1708 IEPulse insert1713 DSTEPower DALI push-buttoncontroller TW1704 ESEElectronic switch insert 1-channel1733 DNERotary satellite insert 3-wireULZ 1755 REGAmplifier LEDUD 1755 REGUniversal dimmer LED1720 NESatellite insert 2-wireLi ght1701 SERelay switch insert 1-channel1723 NESatellite insert 3-wire Light ManagementLight ManagementLB ManagementLB ManagementOverview reference numbers1730 DDStandard rotary dimmer LED 1731 DDUniversal rotary dimmer LEDL it1240 STEPush-button controller1202 URERelay switch insert 2-channel 1224 LEDUDELED universal touch dimmer insert 1225 SDEStandard touch dimmer insert 1208 UI Pulse unit1254 TSETRONIC switch insert 1201-1 URERelay switch insert with floating contact 1252 UDEUniversal 2-gang dimmer insert 1244 NVSELV triac switch insert1220 NESatellite insert “2-wire”1201 URERelay switch insert 1-channel 201 TETimer switch insert1223 NESatellite insert “3-wire”254 NIE1Satellite rotary dimmer insert1730 JEStandard blinds insert 1731 JEUniversal blinds insert B l i n d Blinds ManagementLB Management230 MEMotor control insert 232 MEMotor control insert 32 SDSunlight/dawn sensorULZ 1215 REGUniversal amplifier for rail mountingUD 1255 REGUniversal dimmer for rail mounting225 NVDERotary dimmer insert 225 TDETRONIC rotary dimmer 266 GDERotary dimmer insert 254 UDIE1Universal rotary dimmer insertBlind Blinds ManagementAS rangeBlinds ManagementA rangeCD rangeLB Management LB ManagementA 5232 S..Centre plate with sensor connectionA 5232 T3..Centre plate with timer functionuniversalA 5232 TS3..Centre plate with timer functionuniversalA 5232..Centre plate standardAS 5232 MS..Centre plate with memory functionAS 5232 MS..Centre plate with memory functionAS 5232..Centre plate standardA 5232 BF..Centre plate standardA 5232 BFMS..Centre plate with memory functionA 5232 MS..Centre plate with memory functionA 5232 MS..Centre plate with memory functionBliA 5232 T3..Centre plate with timer functionuniversalA 5232 TS3..Centre plate with timer functionuniversalA 5232 ST..Centre plate with timer functionstandardCD 5232 ST..Centre plate with timer functionstandardCD 5232 TS3..Centre plate with timer functionuniversal and sensor connectionCD 5232..Centre plate standardCD 5232 MS..Centre plate with memory functionCD 5232 MS..Centre plate with memory functionCD 5232 S..Centre plate with sensor connectionCD 5232 T3..Centre plate with timer functionuniversalA 5232 BFMS..Centre plate with memory functionA 5232 BFS..Centre plate with sensor connectionL i g h tLight ManagementLB Management..5201 DTST..Standard timer switch..5201 DTU..Universal timer switch A 1561.07 BF..Standard centre plate..1561.07..Standard centre plate ..1561.07 U..Universal centre plate A 5201 DTST..Standard timer switchCD 5201 DTST..Standard timer switchCD 5201 DTU..Universal timer switch CD 1561.07..Standard centre plate CD 1561.07U..Universal centre plateA 1561.07U..Universal centre plate A 1561.07U BF..Universal centre plate A 5201 DTU..Universal timer switch L i tB l i Blinds Management Light Management LB Management LB ManagementLS rangeAS rangeA rangeA 1561.07..Standard centre plateAS 1561.07..Standard centre plate AS 1561.07U..Universal centre plate.. 5232 ST..Centre plate with timer function standard.. 5232 T3..Centre plate with timer function universal.. 5232 TS3..Centre plate with timer function universal and sensor connection .. 5232..Centre plate standard.. 5232 MS..Centre plate with memory function .. 5232 MS..Centre plate with memory function .. 5232 S..Centre plate with sensor connectionCD rangeLS rangeLight ManagementAu t o m a t i c s w i t c hLight ManagementLight Management LB ManagementLB ManagementLS range.. 1280-1..Universal automatic switch 2.2 mDAW 360..Ceiling automatic switch PMU 360..Universal presence detector.. 1280..Standard automatic switch 2.2 m .. 1180..Standard automatic switch 1.1 m .. 1180-1..Universal automatic switch 1.1 m .. 1180 WU..Standard automatic switch 1.1 m IP44.. 1180-1 WU..Universal automatic switch 1.1 m IP44t t i c s i t c CD rangeAS/A rangeLB Management CD 1280..Standard automatic switch 2.2 m CD 1180-1 WU.. Universal automatic switch 1.1 m IP44A 1180-1 WU..Universal automatic switch 1.1 m IP44A 1280..Standard automatic switch 2.2 mA 1280-1..Universal automatic switch 2.2 mCD 1180..Standard automatic switch 1.1 m CD 1180-1..Universal automatic switch 1.1 m CD 1180 WU..Standard automatic switch 1.1 m IP44A 1180..Standard automatic switch 1.1 m A 1180-1..Universal automatic switch 1.1 m A 1180 WU..Standard automatic switch 1.1 m IP44CD 1280-1..Universal automatic switch 2.2 mALBRECHT JUNG GMBH & CO. KGP.O. Box 132058569 SchalksmuhleGermanyPhone +49 2355 806-553Fax +49 2355 806-254*********************For sales contacts in your country see:/contactBL-BG-P。
Modulay 全箱式灯具说明书

The Modulay range has ingenious design features popular for all types of installations where high quality, competitive luminaires are demanded. The full box, fully enclosed body constructiongives additional strength, whilst reducing light spill into the void, important for open cell ceilings. The housing offers enhanced attachment retention and cleverly maintains the compatibility with both 15mm and 24mm exposed ‘T’ ceilings, including the higher Armstrong Peakform style.The range is offered with a choice of switch start or high frequency control gear and with or without triphosphor lamps. There is also a choice of louvre types and prismatic panel material options.• Fully enclosed body, reducing light spill into the void• Luminaire fits 15 and 24mm exposed ‘T’ ceiling grids• Choice of 65°- 1000 cd/m² or general purpose louvres or prismatic controllers • Fully integral emergency options• Available with a choice of triphosphor or lesslamp optionsModulayW AR R A NT YWA R R A NT YYEAR 591Recessed1Mains lightingModulayLamp and Control Gear Options• 18W, 36W T8 fluorescent 4000°K - G13 cap •4000°K - G5 cap• High frequency or switch start control gear as standard• DSI digital dimming also available Materials• Body - full box steel construction, powder coated in RAL9016 finish•Louvres - high grade specular aluminium• Prismatic controller - TPa flame retardant, UV stable PVC. TPb UV stable styrene Installation Notes• Designed for exposed ‘T’ ceilings with 15mm and 24mm tees• C ompatible with ‘T’ up-stands up to and including the 43.5mm high Armstrong Peakform system • Luminaire lies onto table of tee• Louvre and prismatic controllers fitted by lifting and tilting in and out of body. Louvre supported on hanging straps for hands free re-lamping• High frequency control gear used in conjunction with triphosphor lamps are recommended for the most energy efficient results• Supplied either less lamp or complete with triphosphor lampsDimensionsOptions• Intellem self-test emergency versions available• Suitable for use on defined escape routes with louvre and TPa attachment• Available fitted with pre-wired socket to suit Connect rapid wiring system. Add suffix ‘CX’ to catalogue number • We offer a range of product support contracts to aidcommissioning, reduce your maintenance costs, comply with legislative test requirements and increase the lifespan of yourlighting equipmentSpecificationTo specify state: Lay-in recessed luminaire, of full box construction with post coat powder paint, RAL9016 White, for both 15mm and 24mm tees, for use with 65°-1000 cd/m² mirror finish/ ribbed cross blade general purpose louvre/prismatic controller in TPa/TPb material, as Eaton’s Modulay range, part no. ________Lamp Rating L (mm) W (mm) D (mm) 3/4 x 18W/14W611 593 90 3/4 x 36W/28W/54W 1221 593 90Photometric Data60°90°120°LOR: 0.62ULOR: 0.00DLOR: 0.62SHR nom: 1.50SHR max: 1.557Cat. No. ML418ZT/MLV418Utilisation factors / TM5 R eflectances Room Index C W F 0.75 1.0 1.25 1.5 2.0 2.5 3.04.05.0 70 50 20 48 53 56 59 62 63 65 66 67 30 45 50 53 56 59 61 63 65 66 10 43 4751 54 57 60 61 63 65 50 50 20 48 52 55 57 60 61 63 64 65 30 45 49 52 55 58 60 61 63 64 10 43 47 51 53 56 58 60 62 63 30 50 20 47 51 54 56 58 60 61 62 63 30 44 48 52 54 57 58 59 61 62 10 42 47 50 52 55 57 58 60 61 0 0 0 41 45 49 51 53 55 56 57 58 BZ-class 1 1 1 1 1 1 1 1 1LOR: 0.68ULOR: 0.00DLOR: 0.68SHR nom: 1.50SHR max: 1.66Cat. No. ML414ZT/MLDFR66Utilisation factors / TM5 R eflectances Room Index C W F 0.75 1.0 1.25 1.5 2.0 2.5 3.0 4.0 5.0 70 50 20 46 53 58 61 65 68 69 72 73 30 42 49 54 57 62 65 67 70 71 10 38 46 51 54 59 62 65 68 70 50 50 20 45 52 56 59 63 65 67 69 70 30 41 48 53 56 60 63 65 67 69 10 38 45 50 53 58 61 63 66 68 30 50 20 44 51 55 57 61 63 65 67 68 30 41 48 52 55 59 61 63 65 67 10 38 45 50 53 57 60 62 64 660 0 0 37 4448 51 55 57 59 61 62 BZ-class2 22 2 2 2 2 2 2See page 468 for design guideSee page 468 for design guide601Recessed1Mains lightingModulayCatalogue NumbersLamp RatingLamp TypeModular SizeGear OptionCat NoWeight (kg)Emergency Cat NoWeight (kg)Body - supplied with triphosphor lamps - order attachment separately3 x 18W T8600 x 600High Frequency ML318ZT 3.1 EBML318ZT 4.14 x 18W T8600 x 600 High Frequency ML418ZT 3.2 EBML418ZT 4.23 x 36W T8600 x 1200 High Frequency ML336ZT 5.7 EBML336ZT 6.74 x 36W T8600 x 1200 High Frequency ML436ZT 5.9 EBML436ZT 6.93 x 14W T5600 x 600High Frequency ML314ZT 3.1EBML314ZT 4.14 x 14W T5600 x 600High Frequency ML414ZT 3.2EBML414ZT 4.23 x 28W T5600 x 1200High Frequency ML328ZT 5.7EBML328ZT 6.74 x 28W T5600 x 1200High Frequency ML428ZT 5.9EBML428ZT 6.93 x 54W T5600 x 1200High Frequency ML354ZT 5.7EBML354ZT 6.74 x 54W T5600 x 1200High Frequency ML454ZT 5.9EBML454ZT 6.93 x 18W T8600 x 600DSI Digital Dim ML318RDT 3.3EBML318RDT 4.34 x 18W T8600 x 600 DSI Digital Dim ML418RDT 3.4EBML418RDT 4.43 x 36W T8600 x 1200 DSI Digital Dim ML336RDT 5.9EBML336RDT 6.94 x 36W T8600 x 1200 DSI Digital Dim ML436RDT 6.1EBML436RDT 7.13 x 14W T5600 x 600DSI Digital Dim ML314RDT 3.3EBML314RDT 4.34 x 14W T5600 x 600DSI Digital Dim ML414RDT 3.4EBML414RDT 4.43 x 28W T5600 x 1200DSI Digital Dim ML328RDT 5.9EBML328RDT 6.94 x 28W T5600 x 1200DSI Digital Dim ML428RDT 6.1EBML428RDT 7.13 x 54W T5600 x 1200DSI Digital Dim ML354RDT 5.9EBML354RDT 6.94 x 54W T5600 x 1200DSI Digital Dim ML454RDT 6.1EBML454RDT 7.13 x 18W T8600 x 600 Switch Start ML318ST 3.8 EBML318ST 4.84 x 18W T8600 x 600 Switch Start ML418ST 3.9 EBML418ST 4.93 x 36W T8600 x 1200 Switch Start ML336ST 7.5 EBML336ST 8.54 x 36WT8600 x 1200Switch StartML436ST7.7EBML436ST8.7Body - supplied without lamps - order attachment separately3 x 18W T8600 x 600 High Frequency ML318ZX 2.8 EBML318ZX 3.84 x 18W T8600 x 600 High Frequency ML418ZX 2.8 EBML418ZX 3.83 x 36W T8600 x 1200 High Frequency ML336ZX 5.1 EBML336ZX 6.14 x 36W T8600 x 1200 High Frequency ML436ZX 5.1 EBML436ZX 6.13 x 18W T8600 x 600 DSI Digital Dim ML318RDX 3.0EBML318RDX 4.04 x 18W T8600 x 600 DSI Digital Dim ML418RDX 3.0EBML418RDX 4.03 x 36W T8600 x 1200 DSI Digital Dim ML336RDX 5.3EBML336RDX 6.34 x 36W T8600 x 1200 DSI Digital Dim ML436RDX 5.3EBML436RDX 6.3 3 x 18W T8600 x 600 Switch Start ML318SX 3.5 EBML318SX 4.54 x 18W T8600 x 600 Switch Start ML418SX 3.5 EBML418SX 4.53 x 36W T8600 x 1200 Switch Start ML336SX 6.9 EBML336SX 7.94 x 36WT8600 x 1200Switch StartML436SX6.9EBML436SX6.9Lamp Rating Modular Size (mm)Louvres 65°-1000cd/m 2Louvres Gen Purpose Weight (kg)Louvre attachment - order body separately 3 x 18W 600 x 600 MLV318 MLG318 0.84 x 18W 600 x 600 MLV418 MLG418 0.83 x 36W 600 x 1200 MLV336 MLG336 1.74 x 36W 600 x 1200 MLV436 MLG436 1.7Lamp Rating Modular Size (mm)TPa PVCTPb Styrene Weight (kg)Prismatic Controller - order body separately3 x 18W 600 x 600 MLDFR66 MLD66 0.64 x 18W 600 x 600 MLDFR66 MLD66 0.63 x 36W 600 x 1200 MLDFR612 MLD612 1.24 x 36W 600 x 1200 MLDFR612 MLD612 1.2For more information on the installation requirements and product specifications, please visit our website: https:///content/gb/en/products/product-catalog/recessed-ceiling-lights-modulay-eaton.html611Recessed1Mains lightingModulay。
Allmand 品牌 Port-A-Lite 摆动式灯塔操作手册说明书

PORT-A-LITE AUSTRALIAN STANDARD OPERATOR’SMANUALALLMAND BROTHERS INC.P.O. BOX 888HOLDREGE, NE 68949PHONE: (308) 995- 4495, 1- 800- 562- 1373 ALLMAND FAX: (308) 995– 5887 ALLMAND PARTS DEPT. FAX : (308) 995– 4883PART NO 103586 REVISED JANUARY 2012PORT-A-LITERECORD IMPORTANT INFORMATIONRecording the equipment information will help when placing an order for replacement parts and/ordecals.COMPANY Equip MENT No:Unit Model No:Unit Vin:Accessories:TABLE OF CONTENTSINTRODUCTION 4 SAFETY DEFINITIONS 5 SAFETY PRECAUTIONS 5 SAFETY LABELS 7 PREPARING THE UNIT FOR DELIVERY 7 OPERATION PROCEDURES 8-10 SCHEMATIC 11 WARRANTY 12NOTE: NS = NOT SHOWN. WHEN ORDERING, SPECIFY THE COLOR WANTED ON PARTS CONTAINING THE LETTER “P”INTRODUCTIONABOUT THIS MANUALTAKE TIME TO READ THIS MANUAL THOROUGHLYThis instruction manual provides necessary instructions for the PORT-A-LITE light tower.The information found in this manual is in effect at the time of printing. Allmand Bros Inc. may change contents without notice and without incurring obligation.If you are uncertain about any of the information in the manual, contact Allmand service department at 1-800-562-1373, for clarification.SAFETY DEFINITIONSSafety statements are one of the primary ways to call your attention to potential hazards. Fol-low the precautions listed throughout the man-ual before operation, during operation and dur-ing periodic maintenance procedures for your safety, the safety of others and to protect the performance of equipment. Keep the decals from becoming dirty or torn and replace them if they are lost or damaged. Also, if a part needs to be replaced that has a decal attached to it, make sure to order the new part and decal at the same time.Indicates a hazardous situation which, if not avoided, will result in death or serious injury.Indicates a hazardous situation which, if not avoided, could result in death or serious in-jury.Indicates a hazardous situation which, if not avoided, could result in minor or serious in-jury.This safety alert symbol appears with most safety statements. Itmeans attention,become alert, your safety is in-volved! Read and abide by the mes-sage that follows the safety alertsymbol. Indicates a situation which can cause damage to the equipment, personal property and/or the environment, or cause the equipment to oper-ate improperly.NOTE : provides key information to make pro-cedures easier or clearer.SAFETY PRECAUTIONSThere is no substitute for common sense and careful practices. This information contains gen-eral safety precautions and guidelines that must be followed to reduce risk to personal safety. Special safety precautions are listed in specific procedures. Read and understand all of the safety precautions before operating or perform-ing repairs or maintenance. This safety section cannot cover every situation that may occur that is incidental to the use of the equipment.If you are uncertain about any of the information in the manual, contact Allmand service depart-ment at 1-800-562-1373, for clarification.The safety statements that follow haveDANGER level hazards.ELECTROCUTION HAZARD∙ Do not operate the light tower if the insulation on the electrical cord or other electrical wiring is cut or worn or if bare wires are exposed. Repair or replace damaged wiring before usingthe unit.The safety statements that follow haveWARNING level hazards.UNSAFE OPERATION HAZARD∙ Read and understand this Operator’s Manual, the Engine Operator’s Manual before operating or servicing the light tower to ensure that safe operating practices and maintenance procedures are followed.∙ Never permit anyone to install or operate the equipment without proper training. ∙ Safety signs and decals are additional reminders for safe operating and maintenance techniques.MODIFICATION HAZARD∙ Never modify the equipment without written consent of the manufacturer. Any modification can effect the safe operation of the equipment.EXPOSURE HAZARD∙ Always wear personal protec-tive equipment, including appropriate clothing, gloves, work shoes, and eye andhearing protection, as required by the task at hand.ALCOHOL AND DRUG HAZARD∙ Never operate the light tower while under the influence of alcohol or drugs, or when ill.BURN HAZARD∙ Handle hot components, such as light fixtures, with heat resistant gloves.The safety messages that follow haveCAUTION level hazards.TOOL HAZARD∙ Always use tools appropriate for the task at hand and use the correct size tool for loosening or tightening equipment parts.The safety statements that follow haveNOTICE level .∙Any part which is found defective as a result of inspection or any part whose measured value does not satisfy the standard or limit MUST be replaced.∙ Only use replacement parts specified. Other replacement parts may effect warranty cov-erage.SAFETY LABELSRefer to these representations of the safety warning decals used on the PORT-A-LIGHT light tower to insure correct ordering if replace-ment becomes necessary.PREPARING THE UNIT FOR DELIVERY OR RENTALThe PORT-A-LITE light tower should be oper-ated properly and maintained properly for maxi-mum service life. Never deliver or put machine into service with known defects or missing in-structions or decals. Always instruct the cus-tomer in proper operation and safety proce-dures as described in this Operator’s Manual. Always provide the manual with the equipment for proper and safe operation.CHECK LIST∙ Visually inspect the equipment to ensure that all instructions and decals are in place and legible.∙ Inspect the light tower spring latch assembly which locks the light tower in the vertical po-sition for proper operation.∙ Inspect the light assemblies for damage and test for proper operation.∙ Inspect the electrical wiring for signs of damage.∙ Check to make sure the Operator’s Manual is with the equipment.∙ Inspect the machine physically for damage and repair if necessary.OPERATION PROCEDURESBefore operating the tower light, review Safety on page 5-6.To remove light fixture from storage on base and attach light fixture to mast prior to use:1. Remove the light fixture nut handle and the three washers retaining the light fixture to the base unit and remove the light fixture from the storage bolt.SHO NUT HANDLELIGHT FIXTURE2. Place one of the plastic washers on top of the mast bolt. Then set the light fixture on top of the mast aligning the hole in the light fixture yoke with the mast bolt, place the other plastic washer, one metal washer and the nut handle, then tighten to secure the light fixture on the mast.MAST BOLT4. Connect the male three-pin connector on light fixture cord to the female three-pin con-nector on the base unit cord. Screw on the retaining collar until tight.MALE THTREE-PIN CONNECTORFEMALE THREE-PIN CONNECTOR5. Move the light fixture to the desired position. By rotating the lens and reflector and/or by the light fixture mount.To raise tower to desired height:1. Pull spring latch pin ring out. Raise thetower to the desired height. Retain height by allowing the spring latch pin to engage into one of the three holes in the inner mast sec-tion.TIPPING HAZARDBe sure to keep the base unit level before elevating tower. If the base unit is not level, the entire unit could become unstable and prone to tipping when extending the tower. SPRING LATCH PINHOLES IN INNER MASTGRASP LIGHT FIXTURE HERE TO POSITION RIGHT OR LEFTGRASP LIGHT FIXTURE HERE TO POSITION UP OR DOWNTo operate light fixture:1. Plug base unit cord into wall socket or gen-erator outlet (240V, 50Hz) only.2. Using ON/OFF switch located on the baseunit move switch to ON position.3. The light will begin to illuminate after a briefwarm-up period.To shutdown the unit:1. Using the ON/OFF switch located on thebase turn the switch to the OFF position. 2. Unplug the unit from the (204V, 50Hz) wallsocket or generator outlet.NOTICE:∙ When disconnecting cords, pull on the plug and not the cord.∙ The bulb and light fixture need to cool-down before it can be re-illuminated. Allow 10-15minutes after shut-down before turning thelight fixture on again. ON/OFF SWITCH CORD (240V )ELECTROCUTION HAZARDDo not operate the light tower if the insulation on the electrical cord or other electrical wiring isELECTROCUTION HAZARD Positioning the unit or cord in water can cause electrocution. Always position the unit and cordon dry ground.SCHEMATICSWARRANTYPORT-A-LITE AUSTRALIAN STANDARD PARTS MANUALALLMAND BROTHERS INC.P.O. BOX 888HOLDREGE, NE 68949PHONE: (308) 995- 4495, 1- 800- 562- 1373 ALLMAND FAX: (308) 995– 5887 ALLMAND PARTS DEPT. FAX : (308) 995– 4883PART NO. 103586 REVISED JANUARY 2012TABLE OF CONTENTSSHO 1000W LAMP 3 SHO LAMP HOLDER 4 MAST SECTIONS 5 BALLAST AND CAPACITOR 6 BASE 7 DECALS 8SHO 1000W LAMP1/27/12PORT-A-LITE530555 – 1000W LAMP ASSEMBLY1/27/12 SHO LAMP HOLDERPORT-A-LITEMAST SECTIONS1/27/12 PORT-A-LITEBALLAST AND CAPACITOR1/27/12 PORT-A-LITEBASE1/27/12 PORT-A-LITEDECALS1/27/12 PORT-A-LITE。
cbus系统方案

施耐德莫顿 INSTA BUS EIB智能楼宇控制系统方案施耐德莫顿 INSTA BUS EIB智能楼宇控制系统目录●设计简要●前言一、施耐德 I-BUS 总线控制系统特点及优势二、工程设计三、工程验收及竣工资料四、系统培训及维护设计简要1.品牌选择选用世界最先进的施耐德莫顿EIB/KNX INSTA BUS系统。
遵循欧洲电气安装总线EIB标准,系统具有高可靠性、灵活性、舒适性、安全性、经济性,强扩展能力,强兼容性和开放性。
2.功能实现采用智能面板和智能驱动模块,可定时开闭、调光,光线感应控制。
可统一管理,遥控开启等。
3.集成功能系统采用EIB网关,I- bus系统可接受其他系统干结点信号、交直流信号,实现消防系统、安保系统、音响系统、会议系统的联动,使灯光或设备及时联动。
4.施工EIB I-bus总线是带屏蔽的四芯控制线,可与共同电源线缆敷设,在强电系统中统一考虑,方便、节省。
前言现代化的建筑对于配套设施的需求越来越多样化,既要满足多功能的要求,又要易于操作,同时还要具有高度经济性,灵活性及安全性。
从而对楼宇的智能控制系统提出了更高的要求,越来越多的现代楼宇采用了智能灯光照明控制系统,从而达到了经济合理使用能源的目的,增强了自动化管理的程度,实现了绿色照明,楼宇自控、负荷控制,中央空调、供热系统,门禁、报警系统,无线巡更系统等应用的高度集成,构建起现代化建筑的自动化体系,用最好的性能价格比来迎接智能建筑时代的到来。
施耐德电气(中国)投资有限公司,简称施耐德公司,是一家专业大型电气公司,其EIB/KNX INSTA BUS智能安装系统已在各种建筑领域成熟使用近20年,自2001年进入中国市场以来,在上海F1国际赛车场、上海HYTTA REBENCY HOTEL、上海盛大金磐、北京新源大厦、滨海会展中心等大型项目中已得到使用。
由于施耐德INSTA BUS EIB控制系统的高度集成性和扩展性,向诸多系统提供了标准的物理接口,使该系统使用功能更为强大。
2021年[导演照明师手册]智能照明产品手册
![2021年[导演照明师手册]智能照明产品手册](https://img.taocdn.com/s3/m/ac5cf30680eb6294dc886c21.png)
[导演照明师手册]智能照明产品手册照明师手册(mr_temple 我话密)第一章:基础入门电影制作的每一种技术——生胶片,摄影机,灯光,音效,效果——都包含了成千上万的细微工作,看起来总是非常复杂。
无论在哪一个职位中,想成为 ___必须积累多年的经验并且已经经历了很多不同的实际拍摄情况。
然而,我的经验是,并没有任何一种设备或技术是非常复杂的;也并没有任何一样东西可以在十分钟内解释清楚并完全被掌握。
电影制作是将成千上万与之相关的细节组合起来并加以艺术化的应用。
这本书将帮助你理解其中的一部分。
我们从一名灯光技术员在一部电影制作中所扮演的角色开始讲起。
灯光技术员的工作职能(Job Descriptions of the Lighting Crew)灯光,置景及摄影部门都需服从摄影指导(director of photography: DP)的指挥。
照明组长(或称灯光师:gaffer)与置景主任(key grip)是摄影指导的助手。
照明组长的手下有灯光助理(assistant chief lighting technician)组成,也被称为the best boy electric或second electrician。
在灯光助理之下是电工(electricians),也被称为lamp operators或third electricians。
摄影指导 (Director of Photography) 摄影指导是导演的右手;他(或“她”)是帮助导演作出所有重大决定的人。
摄影指导的主要职责有:将他和导演一同设想好的场景制作成电影;决定使用灯光的正确时间,地点以及气氛;选择最适合于剧情的摄影角度。
摄影指导还将选择光源,根据剧本和导演的要求平衡现实效果与已被风格化的戏剧效果以达到画面要求。
摄影指导还要对布景与服装的设计和色彩提出建议,同时,还要参与拍摄场地的选择。
摄影指导将帮助导演决定每场戏所包含的内容以及决定拍摄不同的摄影角度以提供给剪辑师供剪辑时使用。
智能照明控制模块说明书

一、产品应用领域产品广泛应用于商厦、学校、医院、公园、体育馆、展览馆、工业园区、机场、铁路、车站、变电站等地的灯光控制、消防联动、能耗监测和节能管控二、功能特点1. 1-12路继电器开关输出单元2. 自带场景控制器,多达128个场景3. 每个回路具有灯具保护延时(0-60分钟)4. 每个回路具有分批开启延时(0-25秒)5. 继电器开关可手动控制6. 具有远程编程和管理功能7.自带两路开关量输入,消防,自检反馈,电流检测等功能8. 设备重启可选择已开的场景或指定的场景三、安装连接1.安装条件安装位置要通风良好,注意防潮、防震、防尘。
2. 建筑照明智能化管控系统,采用分层、分区或结构,每个区域采用总线结构,可连接40-50个模块。
区域与中心干线采用10M/100M以太网通讯方式,通过IP网关或Wifi链接有效提高整个系统得数据交换速率。
通讯总线采用RVVP2*2*0.75、RVVP2*2*1.0、RVVP2*2*1.2(根据总线上元件的数量、通信线路长度确定)屏蔽双绞线将各种模块手拉手的并接在总线上,任何模块的损坏不会影响到其他模块的正常运行,安装、维修和更换极为简便。
3.中心通过软件程序,对总线上的各种模块进行编程,可关联总线上任意模块之间的控制关系,只需少量的程序调整,即可实现业主的实际照明要求。
模块采用35mm导轨安装,智能面板采用标准86底盒安装。
l四、MOT型系列智能灯光控制器接线图说明1、输出控制常开触点AC250V/16A(注:负载接线示意图)2、运行和通信状态指示。
3、手动控制开关,现场实验按钮。
4、工作电源:V+,V-:DC12V;VCC,GND:DC12V/ 2A;电源和智能照明模块对应V+连接VCC,V-连接GND,B0,A0,RS-485通信接口,主要与后台总线连接,智能照明控制模块BO,A0之间对应手拉手方式连接,KEY为开关量连接信号或消防接口,B1,A1为抄表连接信号,DS1为温度采集连接信号,I1,I2干接点输入根据现场编程设定五、MOT型系列智能灯光控制器选型▲设计及选型说明1.中心根据实际需要的照明场景,通过编程软件,对总线上的各个模块进行控制关系、照明场景的编程,实现照明智能化控制及照明能源的合理分配及利用。
施耐德莫顿智能照明技术方案

智能照明系统一、概述现代化建筑对照明的要求越来越高,不仅要求提供舒适、绿色的光照,同时不同的场合需要不同的照明环境。
传统的照明控制一般采用开关手动控制,对于上述要求很难实现,而且线路十分复杂,操作非常繁琐。
随着用户要求的提高和技术的进步,传统的照明控制由于许多问题无法解决而逐步被智能照明控制取代,这已成为一种趋势。
宁波电力调度大楼是一座现代化办公楼,本次智能照明设计采用施耐德公司的莫顿智能化照明控制系统,对大楼的不同区域、不同使用功能的照明营造有层次、变化的灯光环境、美化办公及生活环境;减少人力工作疏忽,节约能源和人力资源;降低人力工作强度,增强控制的灵活性和可靠性。
二、设计依据•招标文件技术要求•《民用电气设计规范》JGJ/T16-92•《建筑电气安装工程质量检验评定标准》GYJ1253-88•《民用建筑照明标准规范》GBJ133-90•《智能建筑评估标准》DG/TJ08-602-2001J10105-2001三、设计目的通过智能化照明控制系统,给大楼各功能区域以焕然一新的风格,完成公共区域灯光回路的开关控制,完成整个大楼照明的自动化控制。
智能化照明控制技术是计算机技术、通讯技术、控制技术相结合、相渗透的产物,是现代高新技术的结晶。
与以往的照明控制相比,它从人工控制、单机控制过渡到整体性控制,从普通开关过渡到智能化开关,其最突出的特点是能够预置场景的变化,不同的照明回路强度组合形成不同的“场景”,场景可预置并存储在控制器里,调用时只需按一键就能选择场景和通过预设的程序自动变换场景(可按时顺序、时间、事件等),操作十分方便。
可依据需要实现自动时间控制、自动顺序控制、占空(动静)探测控制、事件程序响应控制、分割空间控制等多种方式的自动控制,也可增加自动日照控制、事件程序响应控制、远程电话控制、远程Internet控制等。
采用莫顿智能照明控制系统完成车库区域、公共走廊、电梯厅、卫生间等公共区域的灯光的控制。
(精品)智能照明系统安装指导手册

智能照明系统安装指导手册V1.2本文件包括机密性信息属于南京天溯自动化控制系统有限公司的私有财产。
此文件及其包含的信息均不得在南京天溯自动化控制系统有限公司的书面同意前为了第三方的利益进行复制,利用和传播目录1系统简介 (1)1.1简介 (1)1.2运行环境 (1)1.2.1网络环境 (1)1.2.2网络模式 (1)1.2.3硬件平台 (2)1.2.4软件平台 (2)1.3附加说明 (2)2 系统安装 (4)2.1安装前提条件 (4)2.1.1 Windows2000/XP操作系统 (4)2.1.2 SQL SERVER数据库及升级包 (4)2.1.3 OFFICE办公软件 (8)2.2系统安装步骤 (9)2.2.1自动安装步骤 (9)2.2.2手动安装步骤 (13)3 系统配置 (21)3.1安装自动完成配置 (21)3.2系统注册 (22)4平台功能介绍 (24)4.1实时监控功能 (24)4.1.1实时图表显示TSView.exe (24)4.1.2实时告警AClientU.exe (28)4.1.3定时与联动控制TSconfig.exe (30)4.2数据安全 (31)4.2.1主从备份 (31)4.2.2权限管理 (41)4.3操作与维护 (50)4.3.1主控台NTS-9000.exe (50)4.4工程配置 (52)4.4.1图表绘制TSDraw.exe (52)4.4.2图元绘制TSEleEdit.exe (75)4.4.3数据配置TSconfig.exe (81)4.4.5策略管理TSStrategyManageU.exe (94)4.4.3 OPC服务器TS Opcserver.exe (96)4.4.4 OPC客户端TS OpcClient.exe (102)4.4.5支持的接口 (110)5智能照明子系统 (111)5.1通讯参数 (111)5.1.1配置规约路径 (111)5.1.2配置通道信息表 (112)5.2设备参数 (112)5.2.1配置网关信息表 (112)5.2.2配置工程项目表 (113)5.2.3导入esf文件 (113)5.2.4配置控制配置表 (114)5.2.5配置文件配置 .................................................................................................................... 错误!未定义书签。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
TRANCENT IP TOUCH-PANEL 10”
KNX
KNX
系统元件
• 这些设备所达到的防护等级为IP20,仅可室内使用。采用其他防 护类型的设备具有单独标记。
160mA 电源供应器
可以为一条最多可带32个总线设备的线路提供总 线电压。带内置扼流器,用于隔离总线的供电; 带开关,用于中断电压并复位连接在线路上的总 线设备。 可以通过附带的插装式螺纹端口连接在线路上。 用于安装在配电柜DIN轨道EN50022上。总线的 连接通过一个总线连接端子完成,无需数据导轨 数据条。
本印刷品版权归施耐德电气 (中国) 投资有限公司所有 , 不得翻印! 内容如有更改,恕不另行通知! MER080001
KNX product overview
施耐德电气 KNX 系统产品目录
KNX SYSTEM
KNX
智能建筑环境控制系统
在离开房间的时候,您是否希望 通过按下某个按键来确保所有的灯和 电器都已经关闭?您是否希望在早晨 按下某个按键放下百叶窗从而营造出 良好的光线氛围?
电源电压:AC 230 V, 50-60 Hz 输出电压:DC 29 V±1 V 输出电流:最大160 mA, 防短路 模块宽度:5 模数 = 约 90 mm
供货范围: 总线连接端子和线路护板。
款式 产品编号 包装单位 PG 备注
浅灰
683429
1/21
9.3
320mA电源供应器(可外接蓄电池)
可以为一条最多可带64个总线设备的线路提供总线电 压。带内置扼流器,用于隔离总线的供电;带开关, 用于中断电压并复位连接在线路上的总线设备。可以 通过附带的插装式螺纹端口连接在线路上。用于安装 在配电柜DIN轨道EN50022上。总线的连接通过一个 总线连接端子完成,无需数据导轨数据条。为了对总 线电压或者IC1互联网控制器的电源进行缓冲,可以 在备用电源输入端上连接一个带DC12V电压 (SELV)的外部铅凝胶蓄电池。通过内置的缓冲电路 可以对6-15Ah铅凝胶蓄电池进行缓冲或重新充电。
在KNX中,与以下部件组合使用: 电源REG-K/640mA,产品编号683890。 附件: 铅酸蓄电池,产品编号668990。 供货范围: 带有总线连接端子和电缆套。
款式
产品编号 包装单位
PG 备注
浅灰
683901 1/10
9.3
扼流器
用于隔离电源 640 REG-K 的第二条线路与总线的连 接。带开关,用于中断电压并复位连接在线路上的 总线设备。 用于安装在配电柜DIN轨道EN 50022-35 x 7.5 (粘 入数据导轨数据条)上。
供货范围: 总线连接端子。
款式
产品编号 包装单位
PG 备注
690299 1/50
9
支线耦合器
可用于支线和区域的逻辑连接和电流隔离,DIN导轨 安装。 总线的连接通过一个总线连接端子完成,无需数据导 轨数据条。主从线路之间的通讯连接通过总线连接端 子实现。
装置宽度: 2 模数 = 约 36 mm 供货范围: 2个总线连接端子。
电源电压:AC 230 V, 50-60 Hz 输出电压:DC 29 V±1 V 输出电流:最大320mA, 防短路 模块宽度:5 模数 = 约 90 mm
供货范围: 总线连接端子和线路护板。
款式 产品编号. 包装单位 PG 备注
浅灰
683729 1/16
9.3
003 KNX SYSTEM | KNX | ©2007
KNX
640mA电源供应器
最多可以为一条带64个总线设备的线路提供总线电 压。带内置扼流器,用于隔离总线的供电;带开关, 用于中断电压并复位连接在线路上的总线设备。通过 一根单独导出的DC29V电源线可以为一条配有专用 扼流器的附加线路供电。 用于安装在配电柜DIN轨道EN50022上。总线的连接 通过一个总线连接端子完成,无需数据导轨数据条。
电源电压:AC 230 V, 50-60 Hz 输出电压:DC 29 V±1 V 输出电流:最大640mA, 防短路 模块宽度:7 模数 = 约 126 mm
供货范围: 2个总线连接端子和2个线路护板。
款式 产品编号 包装单位 PG 备注
浅灰
680401 1/70
9.3
KNX
KNX
总线耦合器
用于连接带插装式应用接口的齐平安装应用模块。 可用螺丝安装在60型安装底盒内。 平面造型结构。带用于编程的LED指示灯和编程按 钮。 安装深度:20 mm
在KNX中与以下装置组合使用: 带插装式应用接口的齐平安装应用 模块。
附件: 防护盖, 产品编号690098。 供货范围: 总线连接端子。
浅灰
683329 1/21
9.3
320mA 电源供应器
可以为一条最多可带64个总线设备的线路提供总 线电压。带内置扼流器,用于隔离总线的供电; 带开关,用于中断电压并复位连接在线路上的总 线设备。 可以通过附带的插装式螺纹端口连接在线路上。 用于安装在配电柜DIN轨道EN50022上。总线的 连接通过一个总线连接端子完成,无需数据导轨 数据条。
产品编号 包装单位 680329 1/70
PG 备注 9.3
数据导轨连接器(2极)
用于通过总线连接端子分别将最多8条信息总线与数据导 轨数据条连接起来。用于安装在配电柜内粘入数据导轨 数据条的DIN EN 50022-35 x 7.5轨道上。 装置宽度: 1 模数 = 约 18 mm
电源电压:AC 230 V, 50-60 Hz 备用电源输入端:用于铅凝胶蓄电池,6-15 Ah, DC 12 V (SELV) 充电电流:最大250 mA 输出电压:DC 29 V±1 V 输出电流:最大320mA, 防短路 模块宽度:5 模数 = 约 90 mm
附件: 铅凝胶蓄电池,产品编号668990。 供货范围: 总线连接端子和线路护板。
电源电压: DC12-30 V (在DC 24 V 40 mA), AC 12-24 V
装置宽度: 2 模数 = 约 36 mm
在KNX中, 与以下部件组合使用: 电源REG,DC 24V/0.4A,产品编号 693003。也可以采用以太网供电(PoE)技术。
供货范围: 带有总线连接端子。
款式 浅灰
款式
产品编号 包装单位
PG 备注
浅灰
680204 1/3/IP路由器可以作为快速干线在不同支线之间通 过局域网(IP)转发报文控制信号。设备还可以用 作一个编程接口,可以将PC与KNX总线连接起来 (比如使用合适的ETS进行ETS编程)。 可以通过一个DHCP服务器或人工配置(ETS参数) 动态分配IP地址。设备按照KNXnet/IP规格使用 Core、设备管理、隧道和路由功能来操作。KNX/IP 路由器能够双向转发报文控制信号,并考虑过滤器 表的因素,最多可以对150个控制信号报文进行缓 冲处理。 安装在符合EN 50022要求的DIN导轨上。使用一个 总线连接端子连接总线,不需要使用数据导轨数据 条。
电网电压:AC 110-230V,50-60 Hz 输出电压:DC 30V±2V 输出电流:最大640mA,防短路 设备宽度:4 模数 = 大约72mm
附件: REG 应急电源,产品编号683901 供货范围: 带有总线连接端子和电缆套。
款式 产品编号 包装单位 PG 备注
浅灰
683890 1/10
9.3
应急电源模块(可接蓄电池)
用来缓冲总线电压。如果出现了一个总体电网故 障,可以将一个电压为DC12V(SELV)的外部铅酸蓄 电池连接到REG电源以便实现缓冲功能。通过内置的 电子充电装置给铅酸蓄电池充电或使其保持在充满 电的状态。 可以连接一个二进制输入,以便记录操作状态。
浅灰
683829 1/16
9.3
640mA电源供应器(可接应急电源模块)
用来在带有不超过64个总线设备的线路中产生总线 电压。带有内置扼流器,可以把电源和总线隔离。 带有一个开关,可以隔离电源并复位与线路相连的 总线设备。可以连接应急电源REG,以便为总线电 压提供缓冲。 安装在DIN EN 50022导轨上。使用一个总线连接端 子来连接总线,不需要数据导轨数据条。
款式 产品编号 包装单位 PG 备注
浅灰
683129
1/21
9.3
2路320mA 电源供应器
可以为一条最多可带64个总线设备的线路提供总线 电压。带内置扼流器,用于隔离总线的供电;带开 关,用于中断电压并复位连接在线路上的总线设备。 可以通过附带的插装式螺纹端口连接在线路上。用于 安装在配电柜DIN轨道EN50022上。总线的连接通过 一个总线连接端子完成,无需数据导轨数据条。
款式
产品编号 包装单位
PG 备注
690099 1/50
9
总线耦合器(2.0版)
用于连接带插装式应用接口的齐平安装面板等。 (如:多功能控制面板或者齐平安装串行数据接 口)。 可用螺丝安装在60型安装底盒内。平面造型结构。 带用于编程的LED指示灯和编程按钮。
安装深度:20 mm
在KNX中与以下装置组合使用: 带插装式应用接口的齐平安装应用模块。 附件: 防护盖,产品编号690098。
电源电压:AC 230 V, 50-60 Hz 输出电压:2 x DC 29 V±1 V 输出电流:最大2 x 320mA, 防短路 模块宽度:7模数 = 约 126 mm
供货范围: 2个总线连接端子和2个线路护板。
款式 产品编号 包装单位 PG 备注
ARTEC
KNX
CONTENTS 目录
KNX系统
003 系统元件 008 接口/网关 010 面板 024 输入模块 027 其它传感器 033 定时器 034 开关控制模块 039 百叶窗/开关控制模块 040 百叶窗控制模块 043 调光控制模块 047 其它控制模块 048 触摸屏及温控面板 056 电源