直流电力电源充电模块ACT230M10III出厂报告
直流电力电源充电模块JYM-II检测报告

直流电力电源充电模块JYM-II检测报告
标题,直流电力电源充电模块JYM-II检测报告。
尊敬的领导:
根据公司要求,我对直流电力电源充电模块JYM-II进行了自查,并将自查结果报告如下:
1. 产品信息核对:
产品型号,JYM-II.
生产日期,2022年1月15日。
生产批次,2022-01-15-001。
产品数量,100个。
产品规格,输入电压220V,输出电压12V,输出电流5A.
2. 外观检查:
外观无明显划痕、变形或损坏。
产品标识齐全,清晰可辨认。
3. 功能检测:
连接电源后,充电模块能正常工作。
输入电压为220V时,输出电压为12V,输出电流为5A。
充电模块能够稳定输出电流,无明显波动或跳变。
4. 安全性能检测:
充电模块符合国家相关安全标准,无明显安全隐患。
充电模块外壳无明显漏电现象。
充电模块在工作过程中无异常发热现象。
5. 质量控制:
生产过程中,严格按照公司质量管理制度进行操作,保证产品质量。
产品生产过程中,进行了多道工序的检测和质量控制,确保产品符合要求。
以上是我对直流电力电源充电模块JYM-II的自查结果,经过检测,该产品符合公司要求和相关标准,可以正常投入市场销售。
如有任何问题或需要进一步了解,请随时与我联系。
感谢您的支持与关注!
此致,。
XXX.
日期,2022年1月20日。
充电模块产品说明书

电力高频开关电源模块技术手册河南耀睿科技有限公司目录第一章概述 (3)一、简述 (3)二、模块主要特点 (3)三、型号命名 (4)四、技术指标 (5)第二章使用环境 (7)第三章模块构成 (7)一、模块的工作原理 (7)二、模块外观及外形尺寸 (8)三、模块安装 (9)四、操作说明 (10)销售服务热线:177-****6500售后服务热线:180-****8778第一章概述一、简述●我公司研发的ZE系列智能型高频开关电源,是专为电力系统设计,具有“四遥”功能的高频开关电源,具有体积小、重量轻、效率高、可靠性高等优点。
产品包括220V和110V两大系列,十几个品种,配有标准RS-485接口,易于与自动化系统对接,适用于各类变电站、发电厂及水电站。
●我公司产品采用了LED数码管显示、注塑面板,进一步提高了产品的可靠性和美观性。
我公司NI型产品主要有以下型号:模块型号额定电压(V)额定电流(A)冷却方式外形尺寸(深×高×宽mm)ZE230D05NI2205自然冷却260×179×109ZE220D07NI2207自然冷却260×179×109ZE230D10NI22010自然冷却325×230×130ZE110D10NI11010自然冷却260×179×109ZE110D20NI11020自然冷却325×230×130二、模块主要特点●效率高,模块效率可达到95%~96%。
●重量轻,体积小。
●采用“三相无源功率因数校正电路”,输入无中线,功率因数可达0.94。
●采用隔离自主均流,并机不均流度<±3%,可保证二十台以上模块良好并机。
●模块内置直流输出隔离二极管,用户无需外设。
●风冷模块风扇为简易更换模式,无需拆装机壳就可快速更换。
●模块具有RS-485接口,方便接入自动化系统进行通信。
直流屏调试报告

试验日期:2004年6月28日-2004年9月28日
●微机控制高频开关电源直流系统
1、铭牌:
2、部件铭牌
3、绝缘检查:
4、报警保护功能:
《直流系统调试报告》
微机控制高频开关电源直流系统●报警保护功能:●
5、交流自投功能检测:
6、电池巡检仪功能检测:
7、绝缘监测仪功能检测:
8、电池组放电试验:
(放电数据见附表。
注:本装置安装了BATM30-2V电池巡检仪,放电全过程观测装置所检测的每个电池的电压,在放电结束前所有单只电池的电压均不低于技术要求规定的。
)
7、试验用仪器仪表:万用表 TX3 True RMS Multimeter—40/110 智能蓄电池组负载测试仪 FZY8、试验结果:合格。
《直流系统调试报告》
试验人员:试验负责人:。
直流电力电源充电模块ACT24MD30III说明

一、ACT24MD30III直流电力电源充电模块称说明概述ACT24MD30III直流电力电源充电模块称可在工作电流范围内进行频繁的操作或多次开断短路电流;机械寿命可高达30,000次,满容量短路电流开断次数可达50次。
直流电力电源充电模块适于重合闸操作并有极高的操作可靠性与使用寿命。
直流电力电源充电模块(普通型)采用了立式的绝缘筒防御各种气候的影响;且在维护和保养方面,通常仅需对操作机构做间或性的清扫或润滑。
直流电力电源充电模块(极柱型)采用了固体绝缘结构—集成固封极柱,实现了免维护。
直流电力电源充电模块在开关柜内的安装形式既可以是固定式,也可以是可抽出式的,还可安装于框架上使用动静触头允许磨损累计厚度mm 3四、直流电力电源充电模块选型用户可根据被保护对象选用不同型号的直流电力电源充电模块,对使用场所的不同可选用防污型和高原型。
为满足市场的需求我厂可根据用户的要求设计各种非标产品。
《直流电力电源充电模块ACT24MD30III》五、直流电力电源充电模块使用条件:1.适用于户内、外;2.环境温度-40℃~+40℃;3.海拔高度不超过3000m(瓷套式不超过1000m);4.电源频率不小于48Hz、不超过62 Hz;5.长期施加在直流电力电源充电模块端子间的工频电压不超过直流电力电源充电模块的持续运行电压;6.地震烈度8度及以下地区;7.大风速不超过35m/s。
8.直流电力电源充电模块保护发电厂、变电站的交流电气设备免受大气过电压和操作电压的损坏。
直流电力电源充电模块是变电站被保护设备免遭雷电冲击波袭击的设备。
直流电力电源充电模块测量电流是否超过电动机的额定电流值,调整整定电流值。
电动机运行时过载,热继电器的辅助头,常闭点断开,常开点闭合的特性进行保护。
在继电控制中把常闭点与停止按钮串入,过载时停止电动机运行,并给出报警信号。
六、直流电力电源充电模块基本原理直流电力电源充电模块是一种过电压(电流)保护器,主要用于保护电力系统、铁道电气化系统、通讯系统中的各种电气设备(变压器、开关、电容器、阻波器、互感器、发电机、电动力、电力电缆等)免遭大气过电压、电流操作过电压(电流)和工频暂态过电压(电流)等损坏,是电力系统绝缘配合的基础。
TLC-JC-DY009 通信用直流-直流模块电源检验报告模板 VA.3-150215

报告编号:×××<计量标志> <CNAS标志>检验报告产品型号产品名称通信用直流-直流模块电源申请单位检验类别产品认证初次/复评检验×××××××××检验中心注意事项1.报告无“检验报告专用章”或检验单位公章无效。
2.报告需加盖骑缝章。
3.复制报告未重新加盖“检验报告专用章”或检验单位公章无效.4.报告无主检、审核、批准人签字无效。
5.报告涂改无效。
6.部分复印本检验报告无效。
7.本检验报告仅对来样负责。
8.对检验报告若有异议,请于收到报告之日起十五日内向泰尔认证中心提出。
地址:××××××邮政编码:××××××电话:××××××传真:××××××网址:××××××E-MAIL:××××××检验报告检验情况一览表检验情况一览表检验结果检验结果页共9 页环境和机械性能试验条件样品信息1 样品信息描述××××××。
{如产品的结构、材质等}2 样品的关键材料信息:见附件3 样品照片样品照片应能反映与检测委托书一致的产品信息(如产品名称、型号/规格、生产厂家){注明样品型号规格}检验使用仪表附件样品的关键材料信息报告编号:××××××检测委托书号:×××申请单位:××××××产品名称:×××产品型号:×××材料名称型号生产厂家主要大功率器件高频变压器×××××检验中心(公章)×××年××月××日。
直流一体充电设备验收报告+培训记录表(通用)

直流一体设备
现场调试验收报告
完成日期:
调试人员:
项目编号:
充电桩群(站)名称:
充电桩群(站)地址:
验收报告
1设备明细
2上电前检查
2.1工艺外观检查
2.2各设备内部线路检查(使用万用表按以下测试项目进行测试时,需确保设备断电情况下执行)
2.3检查柜内各螺丝以及接插件情况
2.4检查绝缘阻值情况
2.5检查进线电压情况
3充电功能检查
3.1 充电机主监控功能
3.2启动停止功能
项目调试人(签名):日期:客户(签名):日期:
客户培训记录表
调试手册能源股份有限公司。
直流电源装置标书(两电三充)技术规范书(修改)
直流电源装置标书(两电三充)技术规范书(修改)220V直流高频开关电源成套装置(两组电池三套充电装置) 技术规范书河南省电力公司二○○七年十二月目录1.总则2.技术要求3.技术服务4.买方工作5.工作安排6.备品备件及专用工具7.质量保证和试验8.包装、运输和储存9.供货范围及报价表附录:两电三充直流系统接线图 1 总则本设备技术规范书适用于220千伏变电所直流系统中采用高频开关电源的直流成套装置的功能设计、结构、性能、安装和试验等方面的技术要求。
本设备技术规范书提出的是最低限度的技术要求,并未对一切技术细节作出规定,也未充分引述有关标准和规范的条文,卖方应提供符合本规范书和工业标准的优质产品。
如果卖方没有以书面形式对本规范书的条文提出异议,则意味着卖方提供的设备(或系统)完全符合本技术规范书的要求。
如有异议,不管是多么微小,都应在报价书中以“对规范书的意见和同规范书的差异”为标题的专门章节中加以详细描述。
本设备技术规范书所使用的标准如遇与卖方所执行的标准不一致时,按较高标准执行。
本设备技术规范书经买、卖双方确认后作为订货合同的技术附件,与合同正文具有同等法律效力。
本设备规范书未尽事宜,买卖双方协商确定。
2 技术要求应遵循的主要现行标准GB/-1993 GB/T7261-1987 GB/17478-1998 JB/T8456-1996 半导体变流器基本要求的规定继电器及继电器保护装置基本试验方法低压直流设备的特性及安全要求低压直流开关设备电力系统直流屏通用技术条件及安全要求电控设备用低压直流电源DL/T5136-2001DL/T459-2000 DL/T5044-2004 DL/T5137-2001 环境条件周围空气温度最高温度:火力发电厂、变电所二次接线设计技术规程电力系统直流电源柜订货技术条件电力工程直流系统设计技术规程电测量及电能计量装置设计技术规程45℃ 1 最低温度:环境相对湿度:日平均90%月平均90%海拔高度:地震烈度:防护等级:工程条件工程概况-10 ℃<1000 m8度IP 31 级 1. 变压器120~240MV A x 2~3台电压220 kV/ 110 kV/ 10(35) kV 2. 电气控制方式:计算机监控方式系统概况直流系统电压:220V 直流系统接线:单母分段接线见直流系统接线图。
ATC230M10Ⅲ、ATC115M20Ⅲ使用说明书
5.1 工作原理 ·········································································································· 4 5.2 主要特点 ·········································································································· 4
二 型号命名··································································································1
三 正常使用条件··························································································1
八 操作指导································································································10
8.1 开机 ················································································································ 10 8.2 关机 ················································································································ 10 8.3 主画面显示 ···································································································· 10 8.4 参数设置操作 ································································································ 11 8.5 模块校验 ········································································································ 13 8.6 多机并联运行 ································································································ 14 8.7 自动 / 手动 ·································································································· 14
9.ATC230M10-IVA模块说明书
fide 二 型号命名 any Con 三 正常使用条件 p 户内使用,正常工作环境温度-10℃~+45℃,+50℃以上降功率输出,大于 60℃过温 m 关机。在设备停用期间,周围空气温度不低于-25℃,不高于+55℃; o日平均相对湿度不超过 95%,月平均相对湿度不大于 90%; C 运行地点无导电或爆炸尘埃,无腐蚀金属和破坏绝缘的气体或蒸汽;
tia 4.3 输出特性 ................................................................................................................2
4.4 保护与报警.............................................................................................................3 4.5 监控特性 ................................................................................................................3
e 五 工作原理及主要特点....................................................................................5 fid 5.1 工作原理 ................................................................................................................5
TLC-JC-DY009 通信用直流-直流模块电源检验报告模板 VB.0-171208
报告编号:×××<计量标志> <CNAS标志>检验报告1产品型号产品名称通信用直流-直流模块电源申请单位检验类别产品认证初次/复评检验2×××××××××检验中心3旗开得胜注意事项1.报告无“检验报告专用章”或检验单位公章无效。
2.报告需加盖骑缝章。
3.复制报告未重新加盖“检验报告专用章”或检验单位公章无效.4.报告无主检、审核、批准人签字无效。
5.报告涂改无效。
6.部分复印本检验报告无效。
7.本检验报告仅对来样负责。
8.对检验报告若有异议,请于收到报告之日起十五日内向泰尔认证中心提出。
4旗开得胜地址:××××××邮政编码:××××××电话:××××××5传真:××××××网址:××××××E-MAIL:××××××6检验报告产品型号/产品名称通信用直流-直流模块电源×××规格出厂编号/×××申请单位××××××生产日期生产单位××××××检验类别产品认证初次/复评检验生产地址××××××送样日期×××年××月××日送样者×××样品基数——样品数量×××样品初始样品初始状态完好,符合检验要求状态检验依据YD/T 1376-2005《通信用直流-直流模块电源》1。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
一、ACT230M10III直流电力电源充电模块称说明概述
ACT230M10III直流电力电源充电模块称可在工作电流范围内进行频繁的操作或多次开断短路电流;机械寿命可高达30,000次,满容量短路电流开断次数可达50次。
直流电力电源充电模块适于重合闸操作并有极高的操作可靠性与使用寿命。
直流电力电源充电模块(普通型)采用了立式的绝缘筒防御各种气候的影响;且在维护和保养方面,通常仅需对操作机构做间或性的清扫或润滑。
直流电力电源充电模块(极柱型)采用了固体绝缘结构—集成固封极柱,实现了免维护。
直流电力电源充电模块在开关柜内的安装形式既可以是固定式,也可以是可抽出式的,还可安装于框架上使用
动静触头允许磨损累计厚度mm 3
四、直流电力电源充电模块选型
用户可根据被保护对象选用不同型号的直流电力电源充电模块,对使用场所的不同可选用防污型和高原型。
为满足市场的需求我厂可根据用户的要求设计各种非标产品。
《直流电力电源充电模块ACT230M10III》
五、直流电力电源充电模块使用条件:
1.适用于户内、外;
2.环境温度-40℃~+40℃;
3.海拔高度不超过3000m(瓷套式不超过1000m);
4.电源频率不小于48Hz、不超过62 Hz;
5.长期施加在直流电力电源充电模块端子间的工频电压不超过直流电力电源充电模块的持续运行电压;
6.地震烈度8度及以下地区;
7.大风速不超过35m/s。
8.直流电力电源充电模块保护发电厂、变电站的交流电气设备免受大气过电压和操作电压的损坏。
直流电
力电源充电模块是变电站被保护设备免遭雷电冲击波袭击的设备。
直流电力电源充电模块测量电流是否超过电动机的额定电流值,调整整定电流值。
电动机运行时过载,热继电器的辅助头,常闭点断开,常开点闭合的特性进行保护。
在继电控制中把常闭点与停止按钮串入,过载时停止电动机运行,并给出报警信号。
六、直流电力电源充电模块基本原理
直流电力电源充电模块是一种过电压(电流)保护器,主要用于保护电力系统、铁道电气化系统、通讯系统中的各种电气设备(变压器、开关、电容器、阻波器、互感器、发电机、电动力、电力电缆等)免遭大气过电压、电流操作过电压(电流)和工频暂态过电压(电流)等损坏,是电力系统绝缘配合的基础。
直流电力电源充电模块的其核心元件采用了以航空标准的先进配方,具有十分优异的非线性(伏一安)特性,即在正常工作电压、电流之下,通过的电流有微安级,当遭受到过电压时,通过的电流瞬间达到数千安培,使避雷器处于导通状态,释放过电压能量,从而有效地限制了过电压对输变电设备的侵害。
传统的直流电力电源充电模块有因放电电压高、操作波放电分散性大导致辞操作波放电电压高等缺点,而扬州福一开关有限公司研发的直流电力电源充电模块具有良好的陡波响应特性,对陡波电压电流无延迟,操作残压低,没有放电分散性等优点,使得陡波、操作波下的保护裕度大大提高,而且在绝缘配合方面,能够作到陡波,雷电波、操作波的保护裕度近接一致,从而对电力设备提供最佳的保护。
直流电力电源充电模块,密封性能良好、防爆性优异,耐污秽免清洗并能减少雾天温闪发生,耐电蚀、抗老化、体积小、重量轻,便于安装和维护。
是20世纪的更新换代产品。
七、直流电力电源充电模块技术标准
产品生产执行的标准为GB11032-2000(eqvIE60099-4.1991)《直流电力电源充电模块》、
JB/8952-20045《直流电力电源充电模块》
八、直流电力电源充电模块产品特点
1、体积小、重量轻、耐碰撞、运输无碰损,安装灵活,适合在开关柜内使用。
2、特殊结构,整体模压成形,无所隙、密封性良好、防潮防爆。
3、爬电距离大,憎水性好,耐污能力强,性能稳定,减少运行维护。
4、独特配方的航空技术标准,泄漏电流小,老化速度慢,使用寿命长。
5、实配直流参考电压、方波通流容量和大电流耐受能力都高于国家标准。
九、用户需知
1、直流电力电源充电模块在安装使用前,应存放在清洁、干燥的房间,不得受到腐蚀性气体或者液体的腐蚀。
2、直流电力电源充电模块在投入运行前,应作预防性试验,在投入运行后,也应定期(10KV以下直流电力电源充电模块5年一次,35KV及以上直流电力电源充电模块2年一次)做如下试验并参照附表与运行前的数据进行对比。
3:测量直流电力电源充电模块的绝缘;
4:测量直流电力电源充电模块的耐压;
十、直流电力电源充电模块出厂报告
直流电力电源充电模块出厂检验报告
检验方式出厂:检验
序号检验名称检验内容检验结果
1 主要配件入厂检验电压,电流,耐压,张力,拉力,合格
2 组装车间7S生产标准人员、机器,坏境合格
3 组装半成品一道检测材料,外观合格
合格4 组装半成品二道检测正常坏境测试(万次比倍测试)
(测试100次出现的损伤,*100是否
达标)
合格5 组装半成品三道检测极限坏境测试(万次比倍测试)
(测试100次出现的损伤,*100是否
达标)
合格6 组装完毕测试装入标准电器组件中(测试多种配套是
否兼容)
7 成品一道检测包装,外观合格
8 出厂检测拍照,扫描合格
经检验各项符合标准规定,准予出厂
检验员:质检公司:扬州福一开关有限公司。