钢结构面积换算表

合集下载

钢材面积换算表

钢材面积换算表

钢材面积换算表Φ20钢管:0. 063㎡/M Φ25钢管:0. 079㎡/M Φ32钢管:0. 1㎡/M Φ38钢管:0. 119㎡/M Φ40钢管:0.126㎡/M Φ57钢管:0.179㎡/M Φ76钢管:0.239㎡/M Φ89钢管:0.279㎡/M Φ108钢管:0.339㎡/M Φ133钢管:0.418㎡/M Φ159钢管:0.499㎡/M Φ219钢管:0.688㎡/M Φ273钢管:0.857㎡/M Φ325钢管:1.02㎡/M Φ377钢管:1.184㎡/M Φ426钢管:1.338㎡/M Φ478钢管:1.501㎡/M Φ530钢管:1.664㎡/M Φ630钢管:1.978㎡/M Φ720钢管:2.261㎡/M Φ820钢管:2.575㎡/M Φ920钢管:2.889㎡/M Φ1020钢管:3.203㎡/M Φ1220钢管:3.831㎡/M Φ1400钢管:4.396㎡/M Φ1600钢管:5.024㎡/M [5槽钢:0.248㎡/M [6.3槽钢:0.286㎡/M [6.5槽钢:0.29㎡/M [8槽钢:0.332㎡/M [10槽钢:0.392㎡/M [12槽钢:0.452㎡/M [14槽钢:0.52㎡/M [16槽钢:0.58㎡/M [18槽钢:0.64㎡/M [20槽钢:0.7㎡/M [22槽钢:0.756㎡/M [24槽钢:0.808㎡/M [25槽钢:0.828㎡/M [27槽钢:0.884㎡/M [28槽钢:0.904㎡/M [30槽钢:0.956㎡/M[32槽钢:1.008㎡/M [36槽钢:1.12㎡/M[40槽钢:1.216㎡/M 工10工字钢:0.472㎡/M 工12工字钢:0.536㎡/M 工12.6工字钢:0.548㎡/M 工14工字钢:0.6㎡/M 工16工字钢:0.672㎡/M 工18工字钢:0.736㎡/M 工20工字钢:0.808㎡/M 工22工字钢:0.888㎡/M 工24工字钢:0.952㎡/M 工25工字钢:0.972㎡/M 工27工字钢:1.036㎡/M 工28工字钢:1.056㎡/M 工30工字钢:1.12㎡/M工32工字钢:1.176㎡/M 工36工字钢:1.28㎡/M工40工字钢:1.384㎡/M 工45工字钢:1.516㎡/M 工50工字钢:1.648㎡/M 工55工字钢:1.78㎡/M工56工字钢:1.8㎡/M 工63工字钢:1.98㎡/M∠20角铁:0.08㎡/M ∠25角铁:0.1㎡/M∠30角铁:0.12㎡/M ∠36角铁:0.144㎡/M∠40角铁:0.16㎡/M ∠45角铁:0.18㎡/M∠50角铁:0.2㎡/M ∠56角铁:0.224㎡/M∠63角铁:0.252㎡/M ∠70角铁:0.28㎡/M∠75角铁:0.3㎡/M ∠80角铁:0.32㎡/M∠90角铁:0.36㎡/M ∠100角铁:0.4㎡/M∠110角铁:0.44㎡/M ∠125角铁:0.5㎡/M∠140角铁:0.56㎡/M ∠160角铁:0.64㎡/M∠180角铁:0.72㎡/M ∠200角铁:0.8㎡/M。

最新钢结构面积和油漆计算

最新钢结构面积和油漆计算

BH每吨 利用平均板厚算平均每顿表面积 构件面 即: 1000/(平均t*7850)*2 (㎡/t)
积 或:每米面积/每米吨数
即:0.5*2+0.4*4 ㎡ (总的表积) (0.5*0.04+0.4*0.02*2)*7.85 t
指构件一米体积
箱型每吨面积计算
例如: 500*300*20*10 每米面积/每米吨数 即:0.5*2+0.3*2 ㎡ (0.5*0.02+0.3*0.01)*2*7.85 t
腹板宽 度 400
翼板宽 度 400
板厚不一BH面积计算
腹板厚 翼板厚 截面积
度度㎡Fra bibliotek2020 0.024
平均板 厚m 0.02
每顿表面积㎡ /t
油漆单价
膜厚
12.7388535
38
100
0 #DIV/0! #DIV/0!
0 #DIV/0! #DIV/0!
例如BH:500*400*40*20 总截面积:S=0.5*0.04+0.4*0.02*2 则平均板厚:t=S/(0.5+0.4*2)
#DIV/0!
#DIV/0!
#DIV/0!
每吨钢构每层用漆价格 =油漆单价*(每吨钢构表面积S/涂 布率)*(实际膜厚/50)(元) 涂布率3.5
#DIV/0!
每吨构件油漆价格
138.3075523 #DIV/0! #DIV/0!
计算稀释液
则1.3倍单价
179.799818 #DIV/0! #DIV/0!
箱型计算
腹板宽 翼板宽 腹板厚 翼板厚 每米构 每米构



度 件面积 件吨数
每顿表面积 油漆单价 膜厚

钢结构防腐换算 各种形状面积换算

钢结构防腐换算 各种形状面积换算

重量换算成平米是58平米/吨,管支架30平米/吨。

焊口数,是10米按1.27个口算量。

管廊上,做跨接线,需要套两个定额,跨接线和构件接地(含材料)。

如果河北省没有跨接线定额需要套避雷引下线加上主材价格。

法兰跨接线,只做跨接线即可。

设备构件接地:大设备4处,小设备2处,泵按1处长方形的周长=(长+宽)×2正方形的周长=边长×4正方形的面积=边长×边长三角形的面积=底×高÷2平行四边形的面积=底×高长方形的面积=长×宽梯形的面积=(上底+下底)×高÷2直径=半径×2半径=直径÷2圆的周长=圆周率×直径= 圆周率×半径×2圆的面积=圆周率×半径×半径圆柱的底面积公式就是圆形的计算公式。

已知底面直径求底面积:(直径÷2)²×3.14已知底面半径求底面积:半径²×3.14拱面积=2*3.14*SR(曲直半径)*拱高长方体的表面积= (长×宽+长×高+宽×高)×2 长方体的体积=长×宽×高正方体的表面积=棱长×棱长×6正方体的体积=棱长×棱长×棱长圆柱的侧面积=底面圆的周长×高圆柱的表面积=上下底面面积+侧面积圆柱的体积=底面积×高圆锥的体积=底面积×高÷3长方体(正方体、圆柱体)的体积=底面积×高阀门类型:Z 闸阀J 截止阀L 节流阀Q 球阀D 碟阀H 止回阀和底阀G 隔膜阀A 安全阀T 调节阀X 旋塞阀Y 减压阀S 疏水阀DZ电磁阀O 电磁动传动方式:1.电磁一液动2.电一液动3.蜗轮4.正齿轮转动5.伞齿轮转动6.气动7.液动8.气一液动9.电动其它手轮、手柄、板手无号表现边接方式;1.内螺纹2.外螺纹3.法兰(用于双弹簧安全阀)4.法兰5.法兰(用于杠杆式、安全门、单弹簧安全门)6.焊接7.对夹8.卡箍9.卡套示密封面或衬里:T 铜合金H 合金钢B 锡基轴(巴承合金氏合金)Y 硬质合金X 橡胶J 硬橡胶SA聚四氟乙烯SB聚三氟乙烯SC 聚氟乙烯SD酚醛塑料SN尼龙表现阀体材料:Z 灰铸件(一般不表现)X 可锻铸铁Q 球墨铸铁T 铜合金B 铅合金II铬钼合金钢L 铬合金P 铬镍钛钢V (II)铬钼钒合金钢R 铬镍钼钛钢 F 氟塑料P 皮革(渗硼钢)S 塑料D 渗氮钢CJ衬胶TC搪磁CS衬塑料CQ衬铅W 密封圈由阀体加工 C 碳钢(一般不表现)G 硅铁。

钢结构计算表及尺寸表

钢结构计算表及尺寸表

2-5 钢结构计算2-5-1 钢结构计算用表为保证承重结构的承载能力和防止在一定条件下出现脆性破坏,应根据结构的重要性、荷载特征、结构形式、应力状态、连接方法、钢材厚度和工作环境等因素综合考虑,选用合适的钢材牌号和材性。

承重结构的钢材宜采用Q235钢、Q345钢、Q390钢和Q420钢,其质量应分别符合现行国家标准《碳素结构钢》GB/T 700和《低合金高强度结构钢》GB/T 1591的规定。

当采用其他牌号的钢材时,尚应符合相应有关标准的规定和要求。

对Q235钢宜选用镇静钢或半镇静钢。

承重结构的钢材应具有抗拉强度、伸长率、屈服强度和硫、磷含量的合格保证,对焊接结构尚应具有碳含量的合格保证。

焊接承重结构以及重要的非焊接承重结构的钢材还应具有冷弯试验的合格保证。

对于需要验算疲劳的焊接结构的钢材,应具有常温冲击韧性的合格保证。

当结构工作温度等于或低于0℃但高于-20℃时,Q235钢和Q345钢应具有0℃C冲击韧性的合格保证;对Q390钢和Q420钢应具有-20℃冲击韧性的合格保证。

当结构工作温度等于或低于-20℃时,对Q235钢和Q345钢应具有-20℃冲击韧性的合格保证;对Q390钢和Q420钢应具有-40℃冲击韧性的合格保证。

对于需要验算疲劳的非焊接结构的钢材亦应具有常温冲击韧性的合格保证,当结构工作温度等于或低于-20℃时,对Q235钢和Q345钢应具有0℃冲击韧性的合格保证;对Q390钢和Q420钢应具有-20℃冲击韧性的合格保证。

当焊接承重结构为防止钢材的层状撕裂而采用Z向钢时,其材质应符合现行国家标准《厚度方向性能钢板》GB/T 5313的规定。

钢材的强度设计值(材料强度的标准值除以抗力分项系数),应根据钢材厚度或直径按表2-77采用。

钢铸件的强度设计值应按表2-78采用。

连接的强度设计值应按表2-79至表2-81采用。

钢材的强度设计值(N/mm2)表2-77注:表中厚度系指计算点的钢材厚度,对轴心受力构件系指截面中较厚板件的厚度。

钢结构重量与面积换算

钢结构重量与面积换算

根据相关有经验的建筑钢结构工程造价人员测定,建筑钢结构重量换算成涂覆表面积的经验数值是:每吨钢结构型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米,如果钢结构每吨在平均厚度10mm时为26平方米,8mm:32平方米,6mm:43平方米,5mm:51平方米;管道面积约为一半。

关于每吨钢结构型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米的说法,在湖北97定额解释说明的防腐工程章说明中,就曾有此说明。

所以我们在计算中完全可以借鉴这一经验换算数值,方便我们将建筑钢结构的重量换算成涂覆表面积进行涂覆工程的计价94定额中,除400以上的型钢及H型钢按面积计算外,其余按5.8mm2/100kg换算;但在03定额做了修改,不得换算,可按照钢结构所用钢材表面积进行换算,与重量无关;但在03定额中有钢结构除锈刷漆的子目,可直接套用(400以上的型钢和H型钢除外)。

网架工程防火涂层又是怎么计算的呢?来源:山东恒大网架钢结构工程有限公司作者:山东网架钢结构发布:2012-11-3 修改:2012-11-3隶属:网架知识点击:830网架工程造价一般采用重量的单位来计算,这是鲜为人知的,然而防火涂层又是怎么计算的呢?防火涂料在工程施工中应用普遍,防雨、防火的特效增加建筑寿命。

它作为直接与保护层直接与构件表面发生有效的载荷系数,目前已经形成了多分类、多等级。

如超薄型、薄型和厚型,耐火等级也可按照等级来确实用量。

涂层采用涂抹覆盖表面积来计算,或者由于建筑工程造价人员测定,每吨网架型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米,如果网架每吨在平均厚度10mm时为26平方米,8mm:32平方米,6mm:43平方米,5mm:51平方米;管道面积约为一半。

关于每吨网架型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米的说法,在湖北97定额解释说明的防腐工程章说明中,就曾有此说明。

所以我们在计算中完全可以借鉴这一经验换算数值,方便我们将建筑网架的重量换算成涂覆表面积进行涂覆工程的计价。

关于钢结构防腐中型钢表面积的计算及数值对照表

关于钢结构防腐中型钢表面积的计算及数值对照表

刚接触防腐的预算才知道动力除锈要用表面积找了半天希望能帮助大家每1m表面积(m2)=2(h-d)+4b-0.8584(r+r1)h:高度(14a为140mm)b:腿宽度(14a为58mm)d:腰厚度(14a为6.0mm)r:内圆弧半径(14a为9.5mm)r1:腿端圆弧半径(14a为4.8mm)计算时各个数据均以"m"为单位,这样算出来的是正反两面表面积之和槽钢表面积对照表序号型号理论重量表面积kg/m M2/t1 [5 5.438 44.8462 [6.3 6.634 42.4923 [6.5 6.709 42.574 [8 8.045 39.3045 [10 10.007 38.8266 [12 12.059 37.2947 [12.6 12.318 37.4888 [14a 14.535 35.0889 [14b 16.733 30.710 [16a 17.24 33.07811 [16 19.752 29.05912 [18a 20.174 31.25513 [18 23 27.57614 [20a 22.637 30.55815 [20 25.777 26.9816 [22a 24.999 29.93417 [22 28.453 26.46318 [24a 26.86 29.55119 [24b 30.628 26.03720 [24c 34.396 23.31921 [25a 27.41 29.70222 [25b 31.335 26.123 [25c 35.26 23.32624 [27a 30.838 28.20525 [27b 35.077 24.92926 [27c 39.316 22.33527 [28a 31.427 28.32528 [28b 35.823 24.97929 [28c 40.219 22.34130 [30a 34.463 27.39131 [30b 39.173 24.19232 [30c 43.883 21.6833 [32a 38.083 26.15134 [32b 43.107 23.18935 [32c 48.131 20.84536 [36a 47.814 23.17537 [36a 53.466 20.79538 [36b 59.118 18.86939 [40c 58.928 20.40940 [40a 65.204 18.50241 [40a 71.488 16.94不等边角钢表面积对照表中国标准热轧H型钢GB/T 11263-19981、“#”表示的规格为非常用规格;“*”表示的规格,目前国内尚未生产;2、型号属同一范围的产品,其内侧尺寸是一致的;3、截面面积计算公式为"t1(H-2t2)+2Bt2+0.858r2。

excel计算大全-钢结构计算表格

excel计算大全-钢结构计算表格

一.1b=100t=10h=230s=6B=200T=104380mm 2152mm 98mm4.6E+07mm 4302773mm 3469607mm 32混凝土等级C208.08板厚h d 100梁跨度6000梁左相邻净距1800梁右相邻净距1800板托顶宽b 0300板托高度h t150b 1 =600b 2 =6001500mm150000mm 222944.4mm 2402mm混凝土板顶面至组合截面中和轴的距离 x= [b e *h d 2/(2*αE )+A*y]/A 0 =117mm混凝土截面惯性矩 I c = b e *h d 3/12=1.3E+08mm 4换算成钢截面的组合截面惯性矩 I 0 = I c /αE + A c *(x-0.5h d )2/αE + I + A(y-x)2 =5E+08mm 43.5E+07mm 42.4E+08mm 43763855mm 41307031mm 4313662.2mm 2混凝土板顶面至组合截面中和轴的距离x c = [b e *h d 2/(4*αE )+A*y]/A 0c =162mm4.2E+08mm 44.2E+07mm 41.1E+08mm 44800913mm 41249942mm 4二施工阶段的验算1弯矩和剪力钢梁自重:0.41kN/m板自重: 6.00kN/m 2000mm)板托重:0.90kN/m6.09kN/m 自重标准值 g 1:7.31kN/m施工荷载: 2.80kN/m施工阶段弯矩设计值M 45.51kN.m (梁跨度:6000mm)施工阶段剪力设计值V 30.34kN2钢梁抗弯强度设计143.14N/mm 2<215N/mm 2PASS!92.29N/mm 2<215N/mm 2PASS!3钢梁剪应力计算面积矩 S=207492mm 322.80N/mm 2<125N/mm 2PASS!4挠度计算考虑混凝土徐变的组合截面特征计算换算成钢截面的组合截面面积 A 0c = A c / 2αE + A =换算成钢截面的组合截面惯性矩 I 0c = I c /(2*αE ) + A c *(x c -0.5h d )2/(2*αE) + I + A(y-x c )2 =(平台梁间距:钢梁剪应力τ1max = v 1*s 1/I*t w =混凝土板截面面积A c = b e * h d =换算成钢截面的组合截面面积A 0=A c /αE +A =对混凝土板底面的组合截面弹性抵抗矩 w 0c b =αE *I 0 / (x - h d ) =对钢梁上翼缘的组合截面弹性抵抗矩 w 0t = I 0 / (d-x) =对混凝土板顶面的组合截面弹性抵抗矩 w 0c tc = 2αE *I 0c / x c =对钢梁下翼缘的组合截面弹性抵抗矩 w 0b = I 0 / (H-x) =组合梁计算截面特征计算钢梁面积 A =b*t + h*s +B*T =钢梁中和轴至钢梁顶面的距离为 y t = [0.5b*t 2 + h*s*(0.5h + t) + B*T*(t+h+0.5T)] / A =钢梁截面特征计算:钢梁中和轴至钢梁顶面的距离为 y b = h + t + T - y t =钢梁截面惯性矩 I= (b*t 3 + s*h 3 + B*T 3) / 12 + b*t*(yt-0.5t)2 + s*h*(y t -0.5h-t)2 + B*T*(0.5T+h+t-y t )2 =钢梁上翼缘的弹性抵抗矩 W 1 = I / y t =混凝土板顶面至钢梁截面中和轴的距离 y = h d + h t +y t =对混凝土板顶面的组合截面弹性抵抗矩 w 0c t = αE *I 0 / x=混凝土板计算宽度b e =钢梁上翼缘的弹性抵抗矩 W 2 = I / y b =组合截面特征计算:钢与混凝土弹性模量比αE =自重标准值 g 1k :对混凝土板底面的组合截面弹性抵抗矩 w 0c bc =2αE *I 0c / (x c - h d ) =对钢梁上翼缘的组合截面弹性抵抗矩 w 0tc = I 0c / (d-x c ) =对钢梁下翼缘的组合截面弹性抵抗矩 w 0bc = I 0c / (H-x c ) =钢梁上翼缘应力 M / r x *W 1 =钢梁下翼缘应力 M / r x *W 2=△=5*g*l 4/(384*E*I)=10.8mm < L/400 =15mm PASS!三使用阶段的验算1弯矩及剪力找平层重: 1.9kN/m活荷载:15.6kN/m (活荷载:6kn/m 2)78.84kN.m52.56kN22.1-2.28N/mm 2<10N/mm 2PASS!-0.33N/mm 2<10N/mm 2PASS!-87.74N/mm 2<215N/mm 2PASS!130.39N/mm 2<215N/mm 2PASS!2.2-2.24N/mm 2<10N/mm 2PASS!-0.37N/mm 2<10N/mm 2PASS!-88.23N/mm 2<215N/mm 2PASS!130.69N/mm 2<215N/mm 2PASS!2.3(略)2.4(略)3钢梁的剪应力147000mm 31105812mm 319.35N/mm 2<125N/mm 2PASS!4组合梁的挠度3.46mm < L/400 =15mm PASS!τ=V 1S 1/It w +V 2S o /I o T w =两个受力阶段的荷载对组合梁的钢梁产生的剪应力△=5q k l 4/384EI o +5g k l 4/384EI o c =组合梁中由于混凝土收缩引起的内力钢梁腹板顶面处对钢梁中和轴的面积矩S 1=钢梁腹板顶面以外的砼及钢梁上翼缘对组合截面中和轴的面积矩S o =使用阶段弯矩设计值M 使用阶段剪力设计值V 组合梁的抗弯强度在垂直荷载作用下的正应力考虑混凝土徐变在垂直荷载作用下的正应力混凝土板顶面应力:σ0c tc =-(M 2g /W 0c tc +M 2q /W 0c t )=混凝土板顶面应力σ0c t =-M/W 0c t =混凝土板底面应力σ0c b =-M/W 0c b =钢梁上翼缘应力σ0t = -M 1/W 1+M 2/W 0t =钢梁下翼缘应力σ0b = -M 1/W 2+M 2/W 0b =σ0bc = -M 1/W 2+(M 2g /W 0bc +M 2q /W 0b )=钢梁下翼缘应力温度差产生的应力σ0c bc =-(M 2g /W 0c bc +M 2q /W 0c b )=混凝土板底面应力:钢梁上翼缘应力σ0tc = -M 1/W 1+(M 2g /W 0tc +M 2q /W 0t )=。

钢结构重量与面积换算

钢结构重量与面积换算

根据相关有经验的建筑钢结构工程造价人员测定,建筑钢结构重量换算成涂覆表面积的经验数值是:每吨钢结构型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米,如果钢结构每吨在平均厚度10mm时为26平方米,8mm:32平方米,6mm:43平方米,5mm:51平方米;管道面积约为一半。

关于每吨钢结构型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米的说法,在湖北97定额解释说明的防腐工程章说明中,就曾有此说明。

所以我们在计算中完全可以借鉴这一经验换算数值,方便我们将建筑钢结构的重量换算成涂覆表面积进行涂覆工程的计价94定额中,除400以上的型钢及H型钢按面积计算外,其余按5.8mm2/100kg换算;但在03定额做了修改,不得换算,可按照钢结构所用钢材表面积进行换算,与重量无关;但在03定额中有钢结构除锈刷漆的子目,可直接套用(400以上的型钢和H型钢除外)。

网架工程防火涂层又是怎么计算的呢?来源:山东恒大网架钢结构工程有限公司作者:山东网架钢结构发布:2012-11-3 修改:2012-11-3隶属:网架知识点击:830网架工程造价一般采用重量的单位来计算,这是鲜为人知的,然而防火涂层又是怎么计算的呢?防火涂料在工程施工中应用普遍,防雨、防火的特效增加建筑寿命。

它作为直接与保护层直接与构件表面发生有效的载荷系数,目前已经形成了多分类、多等级。

如超薄型、薄型和厚型,耐火等级也可按照等级来确实用量。

涂层采用涂抹覆盖表面积来计算,或者由于建筑工程造价人员测定,每吨网架型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米,如果网架每吨在平均厚度10mm时为26平方米,8mm:32平方米,6mm:43平方米,5mm:51平方米;管道面积约为一半。

关于每吨网架型材平均厚度在5mm以下时,折算成涂覆表面积大概为58平方米的说法,在湖北97定额解释说明的防腐工程章说明中,就曾有此说明。

所以我们在计算中完全可以借鉴这一经验换算数值,方便我们将建筑网架的重量换算成涂覆表面积进行涂覆工程的计价。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档