2019锂电池安全测试标准安规)
锂电池检验标准

锂电池检验标准Lithium batteries have become an essential part of our everyday lives, powering everything from smartphones to electric vehicles. With the rise in demand for lithium batteries, there has been a growing need for standardized testing methods to ensure their safety and reliability. 锂电池已经成为我们日常生活中不可或缺的一部分,为智能手机到电动汽车等一切提供动力。
随着对锂电池需求的增加,对其安全性和可靠性进行标准化测试方法的需求也日益增长。
One of the most important aspects of lithium battery testing is safety. It is crucial to ensure that lithium batteries do not overheat, catch fire, or explode during use. This is especially important for electric vehicles, where a battery malfunction could have catastrophic consequences. 锂电池测试最重要的方面之一是安全性。
必须确保锂电池在使用过程中不会过热、起火或爆炸。
对于电动汽车来说,这一点尤为重要,因为电池故障可能导致灾难性后果。
In order to test the safety of lithium batteries, various standards and regulations have been established. These standards cover a wide range of tests, including short circuit tests, overcharge tests, andcrush tests. By following these standards, manufacturers can ensure that their lithium batteries meet the necessary safety requirements. 为了测试锂电池的安全性,制定了各种标准和规定。
锂电池安全测试标准

锂电池安全测试标准锂电池是一种高能量密度的电池,被广泛应用于电动汽车、便携式电子设备和储能系统中。
然而,由于其化学特性和高能量密度,锂电池在使用过程中存在一定的安全隐患。
为了确保锂电池的安全性能,制定了一系列的安全测试标准,以评估锂电池的安全性能和稳定性。
首先,锂电池的安全测试标准包括外观检查、充放电性能测试、短路测试、过充测试、过放测试、高温测试、振动测试等多个方面。
外观检查主要是检查锂电池外壳是否有破损、变形等情况,以确保外壳的完整性。
充放电性能测试则是评估锂电池在充放电过程中的性能表现,包括容量、循环寿命、内阻等指标。
短路测试是为了模拟锂电池在受到外部短路时的安全性能,以确保锂电池在短路情况下不会发生爆炸或火灾。
过充测试和过放测试则是评估锂电池在过充和过放条件下的安全性能,以确保锂电池在异常工作条件下不会出现安全隐患。
高温测试和振动测试则是评估锂电池在高温和振动条件下的安全性能,以确保锂电池在极端环境下依然能够安全可靠地工作。
除了以上测试外,锂电池的安全测试标准还包括了热失控测试、穿刺测试、冲击测试等更加严苛的测试项目。
热失控测试是为了评估锂电池在受到外部热源刺激时的安全性能,以确保锂电池不会因外部热源而发生热失控。
穿刺测试和冲击测试则是为了评估锂电池在受到外部物理损伤时的安全性能,以确保锂电池在受到损伤时不会发生爆炸或火灾。
总的来说,锂电池的安全测试标准涵盖了多个方面,旨在评估锂电池在各种工作条件下的安全性能。
通过严格的安全测试,可以确保锂电池在使用过程中不会出现安全隐患,从而保障人们的生命财产安全。
因此,在生产和使用锂电池时,必须严格遵守相关的安全测试标准,确保锂电池的安全可靠性能。
锂电池安全检测标准

UL1642安全标准(锂电池)前言本标准含有覆盖UL规定的大类的产品的基本要求。
这些要求基于合理的工程原理,研究和试验结论以及现场经验,并且参考了制造商、用户、检查机构和其它一些有专业经验的机构或人士的意见。
A.遵守本标准的要求是制造商在制造产品时应具备的一个基本条件。
B.产品仅能书面满足本标准条文规定不足以断定满足本标准,比如:当检测和试验时,发现其它特征不满足本标准安全水平的要求。
C.产品采用的材料或结构与本标准技术要求不符的不能认为符合本标准。
如果该产品采用的材料或由采用不同于本标准所列的结构形成;但性能可以符合标准要求的,有可能断定符合本标准。
D.UL在执行客户的安全测试要求时,并不承诺为客户的产品负责,UL只是依据当前水平考虑到的一些实际安全限制及要求为产品提供一个专业的判断。
UL对产品造成的危害不承担义务。
E.许多本标准的测试由于其固有的危险性,必须有足够的人身及财产安全防护措施。
简介1. 领域1.1 这些要求包括一次(不可重复充电)和二次(可重复充电)锂电池。
这些电池包括金属Li或Li合金,或Li离子,以及单芯、两个或两个以上多芯串/并联结构的电池组。
1.2 这些要求包括技师可更换的和用户可更换的应用。
1.3 这些要求目的是降低锂电池在用于产品时着火或爆炸的危险。
这些电池能否接受并依赖于他们能否满足所应用的完整产品应符合的要求。
1.4 这些要求也倾向于降低用户更换的Li电池因着火或爆炸而对人身造成的危害。
1.5 这些要求覆盖含Li量≤5g的技师更换型锂电池,对于含Li大于5g的锂电池,即使能满足本规定,仍需进一步测试和检查以确定是否能够应用。
1.6 这些要求覆盖含金属锂≤4g而每个电芯含金属锂≤1g的用户更换型锂电池。
电池含金属锂量>4g或每个电芯金属锂量>1g需要求做进一步测试和验证以确定能否实际应用。
1.7 本要求不包括食入锂电池及其组成物造成的有毒危害,也不包括当电池被切开时对人造成的伤害情况。
锂离子电池的安全性及相关标准规定

锂离子电池的安全性及相关标准规定锂离子电池安全性及相关标准规定锂离子电池是一种高能量密度、长寿命、无记忆效应、环保等优点的电池,被广泛应用于便携式设备、电动工具、电动汽车等领域,但其安全性问题也备受关注。
本文将介绍锂离子电池的安全性及相关标准规定。
一、锂离子电池的安全性问题1. 热失控当锂离子电池内部温度达到一定程度时,电池的正副电极、电解液等将会燃烧甚至爆炸,造成严重事故。
热失控的主要原因是电池内部产生热量无法及时散发出去,导致电池内部温度升高。
2. 机械失控锂离子电池内部物质的结构很脆弱,在受到机械碰撞、摩擦等外力作用时,可能会发生机械失控。
3. 内短路内短路是锂离子电池内部发生短路的一种情况。
由于正负电极之间隔膜被损坏,电解液中的离子可以直接通过短路通道流动,导致电池损坏或甚至爆炸。
4. 外短路外短路发生在电池的正负接口被短路时,电池可以在极短的时间内输出大量电流,可能会引发电池爆炸。
二、锂离子电池相关标准规定1. UL标准UL标准是美国安全试验实验室(Underwriters Laboratories)制定的电池安全标准,主要用于规范锂离子电池的安全性能。
2. IEC标准国际电工委员会(IEC)制定了IEC 62133标准,用于规范电池的安全性能,其中包括锂离子电池。
3. GB/T标准GB/T是中国标准制定机构国家标准化管理委员会发布的标准。
《锂离子电池安全性要求和测试方法》(GB/T 31241-2014)是规范锂离子电池安全性能的重要标准。
4. UN标准联合国(UN)也制定了一系列标准来规范锂离子电池的安全性能,主要针对电池的包装和运输。
综上所述,锂离子电池的安全性问题备受关注,相关标准规定的制定和实施对于确保锂离子电池的安全性具有关键性作用。
同时,生产、使用锂离子电池时也要严格按照标准规定进行操作,尽可能避免电池对人身和环境造成损害。
未来发展趋势和前景随着科技的不断发展和新能源的广泛应用,锂离子电池的前景越来越广阔。
锂电池安全标准

锂电池安全标准锂离子电池常见的五个安全标准是:1、IEC621332、UN/DOT38.33、IEC626194、UL16425、UL2580IEC62133是锂离子电池和电池的安全测试标准,是测试含有碱性或非酸性电解质的二次电池和电池的安全要求。
它用于测试便携式电子产品和其他应用中使用的LIB。
IEC62133解决了可能威胁消费者和环境的化学和电气危害以及振动和冲击等机械问题。
UN/DOT38.3(也称为T1-T8测试和UNST/SG/AC.10/11/Rev.5)涵盖所有LIB、锂金属电池和电池的运输安全测试。
测试标准包括八项测试(T1–T8),均侧重于特定的运输危险。
UN/DOT38.3是一个自我认证标准,不需要独立的第三方测试,但使用第三方测试实验室是常见的,以减少发生事故时的诉讼风险。
UL1642是锂电池安全的UL标准,规定了在电子产品中用作电源的一次和二次锂电池的标准要求。
UL1642涵盖:(1)、技术人员可更换的锂电池,含有5.0克(0.18盎司)或更少的金属锂。
锂含量超过5.0克的电池将根据其是否符合要求(如适用)进行判断,并进行额外的测试和检查,以确定电池是否可用于其预期用途。
(2)、用户可更换的锂电池,每个电化学电池中金属锂含量不超过4.0克(0.13盎司),金属锂含量不超过1.0克(0.04盎司)。
超过4.0克的电池或超过1.0克锂的电池需要进一步检查和测试,以确定电池或电池是否可以用于其预期用途。
IEC62619涵盖了二次锂电池和电池组的安全标准,规定了LIB 在电子和其他工业应用中的安全应用要求。
IEC62619标准测试要求适用于静止和动力应用。
固定应用包括电信、不间断电源(UPS)、电能存储系统、公用事业开关、应急电源和类似应用。
动力应用包括叉车、高尔夫球车、自动引导车辆(AGV)、铁路和船舶——不包括公路车辆。
UL1642不涵盖因摄入锂电池而导致的毒性风险,或因电池损坏或切开而导致接触金属锂的风险。
锂离子测试标准-安全测试

1.0范围SCOPE本规范规定了锂离子电池定义、要求、测验方法、测试频次和数量;本规范适用于公司所有的锂离子电池。
This criterion describes the definition, requirement, test method, test frequency and amount.This criterion only applies to Li-ion battery produced by B&K.2.0变更记录CHANG RECORD3.0引用标准REFERANCE下列是本文引用的标准。
执行本规范时,所示版本均应该为有效版本。
使用本规范的各部门应注意下列引用标准是否是最新版本。
There are the references in this document. The edition of references is valid edition. All of the department using this criterion should notice the edition of the references.GB/T2828-1987逐批检查计数抽样程序及抽样表(适用于连续批的检查)GB/T2829-1987周期检查计数抽样程序及抽样表(适用于生产过程稳定性的检查)GB/T2900.11-1988蓄电池名词术语GB/T18287-2000蜂窝电话用锂离子电池总规范4.0 定义DEFINITION4.1充电限制电压--电池由恒流充电转入恒压充电时的电压值.Limited charge voltage—the voltage of constant current switches to constant voltage when battery is charged.4.2标称容量—指电池在环境温度为25±2℃的条件下,以5h率放电至终止电压时所应提供的电量,用C5表示,单位为Ah(安培小时)或mAh(毫安小时).Rated capacity—under 25±5℃,65±5%RH,i t means the capacity value of being charge by 5h ratio to cut-off voltage. The capacity value can be expressed with code C5. The unit is Ah or mAh.5.0测试条件和要求TEST CONDITIONS and REQUIREMENT5.1测试条件Testing conditions除非测试项目另有规定,本规范中各项测试应在以下条件下进行.All of the testing is done on the conditions hereinafter, unless there is other requirement.温度:25℃±2℃; 相对湿度:45%±20%;大气压力:86kPa—106kPaTemperature: 25℃±2℃;Related humidity: 45%±20%;Atmospheric pressure: 86kPa—106kPa5.2测量仪表与设备要求Requirement of the testing equipment and meter测量电压的仪表准确度应不低于0.5级,内阻应不小于10kΩ/V.The precision of meter used to measure voltage is no less than degree 0.5, and equipment used to measure internal resistance is no less than 10kΩ/V.测量电流的仪表准确度应不低于0.5级. 测量时间用的仪表准确度不低于±0.1%.The precision of meter used to measure current is no less than degree 0.5, and the precision of meter used to measure time is no less than degree ±0.1%.测量温度的仪表准确度应不低于±0.5℃. 恒压源电压可调,其电压变化范围为±0.5%.The precision of meter used to measure temperature is no less than degree ±0.5℃. The constant voltage source can be adjust with range of voltage change is ±0.5%.恒流源的电流恒定可调,在充电或放电过程中,其电流变化应在±1%范围内.The constant current source can be adjust with range of current change is ±1% during charge or discharge.6.0测试方法TEST METHOD6.1外观Appearance电池表面应清洁;无划伤、破裂、污迹、锈蚀、变形、漏液等缺陷。
锂电池测试标准

锂电池测试标准
锂电池作为一种重要的电池类型,广泛应用于移动电子设备、电动汽车、储能
系统等领域。
为了确保锂电池的安全性能和可靠性,需要对其进行严格的测试。
本文将介绍锂电池测试的相关标准,以便为相关行业提供参考。
首先,锂电池的测试标准主要包括安全性能测试、电性能测试和环境适应性测试。
安全性能测试包括过充、过放、短路、振动、冲击等测试,以验证锂电池在各种极端情况下的安全性能。
电性能测试主要包括容量、循环寿命、内阻、自放电率等测试,以评估锂电池的电性能指标。
环境适应性测试则包括高温、低温、高湿度、低压等测试,以验证锂电池在各种环境条件下的适应性能。
其次,锂电池测试标准的制定应遵循国际标准和行业标准。
国际标准如IEC 62133、UN 38.3等,是全球范围内通用的锂电池测试标准,具有权威性和可靠性。
行业标准则是针对特定行业领域的锂电池测试标准,如电动汽车行业的GB/T 31485、储能系统行业的GB/T 31467等,具有针对性和实用性。
最后,锂电池测试标准的执行需要符合相关的测试设备和测试方法。
测试设备
包括充放电测试系统、内阻测试仪、环境试验箱等,用于对锂电池进行各项测试。
测试方法则是根据标准规定的测试流程和要求,进行测试操作和数据采集,以确保测试结果的准确性和可比性。
总之,锂电池测试标准是保障锂电池安全性能和电性能的重要手段,其制定和
执行对于推动锂电池产业的健康发展具有重要意义。
希望本文介绍的内容能够为相关行业提供参考,促进锂电池测试标准的规范化和统一化,推动锂电池产业的可持续发展。
锂电池 寿命 测试 标准

锂电池寿命测试标准锂电池作为现代电子设备的核心能源,其性能和寿命至关重要。
近年来,随着科技的飞速发展,锂电池在消费电子、电动汽车以及储能等领域得到广泛应用。
然而,锂电池的寿命问题一直是业内关注的焦点。
如何正确测试锂电池的寿命,以及如何提高其使用寿命,成为行业迫切需要解决的问题。
锂电池寿命测试主要包括以下几个方面:1.充放电循环测试:通过测量锂电池在一定次数的充放电循环后的容量变化,评估电池的寿命。
一般来说,锂电池的寿命是用充放电循环次数来衡量的,当电池容量衰减到原有容量的80%时,即可认为电池寿命结束。
2.容量保持率测试:在不同的存储条件下,如温度、湿度等环境因素变化,测试锂电池的容量保持率。
这一指标可以反映电池在实际使用过程中的性能稳定性。
3.温度循环测试:通过在不同温度条件下对锂电池进行充放电循环测试,观察电池性能的变化。
温度是影响锂电池寿命的重要因素,因此了解电池在不同温度下的性能表现,有助于优化电池设计和提高使用寿命。
4.存储寿命测试:在特定的存储条件下,如温度、湿度等环境因素,测试锂电池的存储寿命。
存储寿命是指电池在未经使用的情况下,其性能衰减到一定程度所需的时间。
要提高锂电池寿命,可以从以下几个方面着手:1.材料选择:采用高性能的正极、负极和电解质材料,以提高电池的能量密度和循环寿命。
2.电池设计优化:优化电池的结构设计,如减小电池的内阻、提高电池的充放电效率,从而降低电池的损耗。
3.电池管理系统应用:采用电池管理系统(BMS)对锂电池进行实时监测和控制,确保电池在安全、合理的范围内工作,避免过充、过放等现象发生,从而延长电池寿命。
我国锂电池产业发展现状喜人,产能持续扩大,技术不断突破。
在政策的扶持下,新能源汽车、储能等领域的锂电池需求迅速增长。
然而,与国际先进水平相比,我国锂电池在关键材料、制造工艺等方面仍有一定差距。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
跌落
6pcs
4
短路
3pcs
5
过充
3pcs
在跌落实验6pcs中抽取3pcs
3、范围:
容量、寿命、过充、过放、振荡、短路、跌落,重物冲击。
4、性能:
等同于国标或优于国标。
容量测试
1、使用仪器:
路华RF检测仪,新威检测仪。
2、使用方法:
使用检测仪保护电压在2.50V—4.35V,保护电流为正负2000mA。在环境温度15℃-25℃的条件下,设定操作如下:
2.1以1C5A恒流充电,电压限制4.20V。
2.2以4.20V恒压充电,电流限制20mA。
2.3静置5min。
2.4以1C5A恒流充电,电压下限2.75V。
2.5停止。
3、品质要求:
放电时间不低于54min,电池外观无变形,无爆裂、漏液、冒烟、起火等现象。
振动测试
1、使用仪器:
多频振动台、电压内阻检测仪。
1、使用仪器:
路华、瑞能、新威检测仪,安全测试桶。
2、使用方法:
2.1将接有引出片的电池置于安全测试桶内,连接正负极于检测仪。
2.2设置检测仪工步:在无保护电压与保护电流的条件下
1恒流充电:0.2C、0.5C、1C充电到5.00V。
2恒压充电:5.00V充电到电流变为40mA。
3静置:5min。
4停止。
2.3检测电压。
3、品质要求:
电池外观无损伤、无漏液、冒烟、起火、爆炸现象。
过放测试
1、使用仪器:
路华、瑞能、新威检测仪,安全测试桶。
2、使用方法:
2.1将接有引出片的电池置于安全测试桶内,连接正负极于检测仪。
2.2设置检测仪工步:在无保护电压与保护电流的条件下
①恒流放电:0.2C、0.5C、1C放电,电压限制为50mV。
短路
3pcs
重物冲击
3pcs
2.2每一批号电池化成结束随即抽检4pcs做容量,寿命检测。
工步
检验项目
抽检数量
备注
1
容量
4pcs
2
寿命
4pcs
2.3每一批出货电池的每一种型号都抽检20pcs做容量,振荡,跌落,短路,过充检测。
工步
检验项目
抽检数量
备注
1
容量
8pc振荡
20pcs
2.1环境温度15℃-25℃的条件下,以1C5A充电,电压达到4.20V时,恒压充电10min。
2.2使用电压内阻测试仪测试电压内阻。
2.3电池从一米高度,三个不同的方向。正、反各跌落1次。
2.4重新测试电压内阻。
3、品质要求:
电池电压内阻无明显变化,电池外观无损伤、无漏液、冒烟、起火、爆炸现象。
过充测试
1、目的:
检测电池的安全性能。
2、内容:
随机抽检且抽检比例不大于1%。
2.1新型号电池投产,化成结束随机抽检20pcs做安全性实验。
工步
检验项目
抽检数量
备注
1
容量
20pcs
2
振荡
20pcs
3
寿命
8pcs
跌落
6pcs
4
过充
3pcs
在跌落实验6pcs中抽取3pcs
过放
3pcs
在跌落实验6pcs中抽取3pcs
②静置:5min。
③停止。
2.3检测电压。
3、品质要求:
电池外观无损伤、无漏液、冒烟、起火、爆炸现象。
重物冲击
1、使用仪器:
10kg重锤,冲击台,电压内阻测试仪。
2、使用方法:
2.1电池充电至4.20V。
2.2电池放置于冲击台上,电池的最大面应与台面垂直。
2.3将10Kg重锤直1m高度自由落下,冲击已固定的电池。
2.4检测电压内阻。
3、品质要求:
电池允许发生变形,但无漏液、冒烟、起火、爆炸现象,且电池电压内阻无明显变化。
短路实验
1、使用仪器:
铜板、安全保护桶、电压内阻测试仪。
2、使用方法:
2.1电池充电至4.20V。
2.2将电池两端引出连接片。
2.3在安全保护桶内,连接电池正负极连接片,压于铜板之下。直至电池不再放电为止。
电池电压内阻无明显变化,电池外观无损伤、无漏液、冒烟、起火、爆炸现象。
循环寿命测试
1、用仪器:
路华RF检测仪,新威检测仪。
2、使用方法:
使用检测仪保护电压在2.50V—4.35V,保护电流为正负2000mA。
在环境温度15℃-25℃的条件下,设定操作如下:
2.1以1C5A恒流充电,电压限制4.20V。
2.2以4.20V恒压充电,电流限制20mA。
2.3静置5min。
2.4以1C5A恒流充电,电压下限2.75V。
2.5静置5分钟。
2.6重复1至5工步。
3、品质要求:
方形电池循环次数不低于500次。
圆柱形电池循环次数不低于300次。
跌落测试
1、使用仪器:
直尺、跌落平台、电压内阻测试仪。
2、使用方法:
2.4检测电压内阻。
3、品质要求:
电池不允许发生变形,且无漏液、冒烟、起火、爆炸现象,电池电压内阻无明显变化。
2、使用方法:
2.1环境温度15℃-25℃的条件下,以1C5A充电,电压达到4.20V时,恒压充电10min。
2.2用电压内阻检测仪检测电池电压内阻。
2.3将电池直接安装或通过夹具安装在振动台上。
2.4调节振幅为2.5mm,振动1h.然后把电池反向固定,重复振动1h。
2.5重新测试电压内阻。
3、品质要求: