ABB 接触器及热继尺寸

Manual Motor Starters MS 116, MS 325, MS 450, MS 495 ..................................................................................... 9/69
Thermal and Electronic O/L Relays TA 25 DU, TA 42 DU, TA 75 DU, TA 80 DU, TA 110 DU, TA 200 DU, TA 450 DU/SU ...... 9/72 E 16 DU, E 200 DU, E 320 DU, E 500 DU, E 800 DU, E 1250 DU ..................................... 9/74 T 7 DU ...........ቤተ መጻሕፍቲ ባይዱ...................................................................................................................... 9/77
Mini Contactors with Thermal O/L Relays and with Accessories B 6, B 7, BC 6, BC 7 ............................................................................................................ 9/76
Only major dimensions are quoted on the drawings contained in this section. Detailed dimension drawings on request.
Specific Contactors UA 16..RA ... UA 110..RA .................................................................................................... 9/63 UA 16 ... UA 110 .................................................................................................................. 9/65 GA 75 and GAE 75 .............................................................................................................. 9/66 AM 45, AM 50 and AM 75 .................................................................................................... 9/67 EH 1200 ............................................................................................................................... 9/68
9 NL, NL Z, TNL ...................................................................................................................... 9/55
K 6 and KC 6 ........................................................................................................................ 9/76
Contactor Relays and Mini Contactor Relays with Accessories N .......................................................................................................................................... 9/47
9/0
Dimensions
Contents
3-pole Contactors with Thermal or Electronic O/L Relays and with Accessories A 9, A 12 and A 16 ................................................................................................................. 9/2 A 26 ........................................................................................................................................ 9/4 A 30 and A 40 ........................................................................................................................ 9/6 A 50, A 63, A 75, AF 50, AF 63 and AF 75 ............................................................................ 9/8 A 95, A 110, AF 95 and AF 110 ........................................................................................... 9/10 A 145, A 185, AF 145 and AF 185 ....................................................................................... 9/12 A 210, A 260, A 300, AF 210, AF 260 and AF 300 .............................................................. 9/15 AF 400 and AF 460 .............................................................................................................. 9/18 AF 580, AF 750, AF 1350 and AF 1650 ............................................................................... 9/21 AL 9, AL 12, AL 16, AL 9..Z, AL 12..Z, AL 16..Z, TAL 9, TAL 12 and TAL 16 ..................... 9/28 AL 26 and TAL 26 ................................................................................................................ 9/30 AL 30, AL 40, TAL 30 and TAL 40 ....................................................................................... 9/32 AE 50, AE 63, AE 75, TAE 50 and TAE 75 .......................................................................... 9/34 AE 95, AE 110, TAE 95 and TAE 110 ................................................................................. 9/36 A Series Contactors with LD.. Additional Terminal Blocks ................................................... 9/38 A Series Contactors with BEA.. Connecting Links and MMS - PM 26.. Mounting plate ...... 9/40
4-pole Contactors with Accessories A 9 and A 16 ........................................................................................................................ 9/47 A 26 ...................................................................................................................................... 9/49 A 45, A 50, A 75, AF 45, AF 50 and AF 75 .......................................................................... 9/51 EK 110, EK 150, EK 175, EK 210, EK 370, EK 550 and EK 1000 (a.c. Operated) ............. 9/53 AL 9, AL 12, AL 16, TAL 9, TAL 12 and TAL 16 .................................................................. 9/55 AL 26 and TAL 26 ................................................................................................................ 9/57 AE 45, AE 50, AE 75, TAE 45, TAE 50 and TAE 75 ............................................................ 9/59 EK 110, EK 150, EK 175, EK 210, EK 370, EK 550 and EK 1000 (d.c. Operated) ............. 9/61
合集下载

abb接触器参数说明

abb接触器参数说明

abb接触器参数说明摘要:I.接触器简介A.接触器的作用B.接触器的种类II.ABB 接触器参数说明A.额定电压B.额定电流C.额定功率D.工作制种类E.使用类别III.ABB 接触器型号及含义A.微型接触器B.空气断路器C.塑壳断路器D.框架断路器IV.接触器应用领域A.建筑业B.工业领域C.电力行业正文:ABB 接触器是一种用于控制电路的开关装置,具有很高的性能和稳定性。

作为全球领先的工业自动化和电力技术供应商,ABB 接触器被广泛应用于各种领域。

接下来,我们将详细介绍ABB 接触器的参数说明以及应用领域。

一、接触器简介接触器主要用于控制电动机和其他电感性负载,可以实现接通和分断电路的功能。

根据工作原理和结构的不同,接触器可以分为多种类型,如电磁式接触器、真空接触器、空气接触器等。

在实际应用中,根据负载的特性和工作环境的要求,选择合适的接触器是非常重要的。

二、ABB 接触器参数说明1.额定电压:额定电压是指接触器能正常工作的电压值。

不同的接触器型号具有不同的额定电压,用户在选择时需要根据实际应用需求进行选择。

2.额定电流:额定电流是指接触器在额定电压下能正常工作的电流值。

额定电流的大小决定了接触器的负载能力,用户在选择时需要根据负载的大小进行选择。

3.额定功率:额定功率是指接触器在额定电压和额定电流下能承受的功率。

额定功率反映了接触器的功率承受能力,用户在选择时需要根据负载的功率进行选择。

4.工作制种类:工作制种类是指接触器在正常工作条件下的工作方式。

根据不同的工作制种类,接触器可以分为长期工作制、短时工作制和断续工作制等。

5.使用类别:使用类别是指接触器在实际应用中可能遇到的环境条件和使用要求。

根据不同的使用类别,接触器可以分为标准型、防尘型、防水型等。

三、ABB 接触器型号及含义ABB 接触器型号繁多,根据负载类型和应用领域的不同,可以分为微型接触器、空气断路器、塑壳断路器和框架断路器等。

ABB接触器概述

ABB接触器概述

ABB接触器概述:接触器适用于建筑业和工业领域,如:电机控制、保暖和通风、空调、水泵、提升设备、照明和校正功率因数等。

ABB接触器的规格包括4 和 5.5KW 的微型接触器、高达400kW 的接触器组(AC3),建筑用接触器(家用和工业用),拍合式接触器,热过载继电器和电子继电器,以及完整的附件,确保选择灵活性和满足客户需求,公司制造工厂位于海西经济区的核心----美丽的鹭岛厦门。

通用型接触器-交流操作接触器-直流操作接触器适用范围A9 ... A300 接触器主要用于控制三相电动机以及额定工作电压达690 VAC / 1000 V AC 或220 V DC / 600 V DC 的电力线路。

并可适用于其他应用场合,如隔离、电容器组切换、照明控制等。

AF09 ... AF38 接触器用于控制电压至 690 V AC 和 220 V DC 的电源回路。

它们主要用于控制三相电动机、非感性负载或微感负载。

AF09 ... AF38 接触器带有 1 个电子线圈接口,可接受很宽的控制电压范围 Uc min ... Uc max。

三种线圈涵盖 24...250 V 50/60 Hz 或20 ... 250 V DC 之间的控制电压• AF 接触器具有很强的抗控制电压波动能力。

一种线圈(如 100 ...250 V 50/60 Hz - DC)可适用于全球范围内各种控制电压,无需更换线圈• AF .. Z 接触器配有 1 个 Z 型线圈,可直接由 24 V DC 500 mA 的PLC 输出控制,它同时具有很低的保持功耗。

可耐受短时压降和电压中断(符合 SEMI F47-0706)AF50 ... AF2050 接触器主要用于三相电动机以及额定工作电压达 690VAC / 1000 V AC 或220 V DC / 600 V DC。

适用于旁路、电容器组切换、照明控制、直流电力线路控制等其他应用场合。

AF 系列接触器带交直流通用、宽电压、电子式控制线圈,无论控制电 源为交流50/60Hz 或直流,均可直接接至控制线圈,无需考虑不同国家的电力网络及控制电源种类不同等问题。

接触器与热继电器选型表

接触器与热继电器选型表

接触器与热继电器选型表接触器与热继电器选型表施耐德电动机接触器与热继电器选型表序号功率断路器直接启动星三角启动备注接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 C65N 3P D16A LC1-D09M7CLRD04C0.63~1A0.56A2 0.37 C65N 3P D16A LC1-D09M7C LRD06C 1~1.6A 1.1A3 0.55 C65N 3P D16A LC1-D09M7CLRD07C1.6~2.5A1.5A4 0.75 C65N 3P D16A LC1-D09M7CLRD07C1.6~2.5A2A5 1.1 C65N 3P D16A LC1-D09M7C LRD08C 2.5~4A 2.8A6 1.5 C65N 3P D16A LC1-D09M7C LRD08C 2.5~4A 3.7A7 2.2 C65N 3P D16A LC1-D18M7C LRD10C 4~6 5.3A8 3 C65N 3P D16A LC1-D18M7C LRD12C 5.5~8 7A9 3.7 C65N 3P D16A LC1-D18M7C LRD14C 7~10 8A10 5.5 C65N 3P D20A LC1-D18M7C LRD16C 9~13 12A11 7.5 C65N 3P D25A LC1-D18M7C LRD21C 12~18 15A LC1-D12M7C LC1-D09M7C LRD14C 7~10 7A12 9 C65N 3P D25A LC1-D25M7C LRD22C 17~24 18A LC1-D18M7C LC1-D09M7C LRD16C 9~13 9A13 11 C65N 3P D32A LC1-D32M7C LRD22C 17~24 23A LC1-D18M7C LC1-D09M7C LRD16C 9~13 11A14 15 NSE100N 3P 50A MA LC1-D40M7C LRD33 53C 30A LC1-D25M7C LC1-D12M7C LRD21C 12~18 14A23~3215 18.5 NSE100N 3P 50A MA LC1-D25M7C LC1-D12M7C LRD22 17~25 18A16 22 NSE100N 3P 50A MA LC1-D32M7C LC1-D18M7C LRD-32 23~32 21A17 30 NSE100N 3P 50A MA LC1-D38M7C LC1-D18M7C LRD-35 30~38 29A18 37 NSE100N 3P 100AMALC1-D50M7C LC1-D25M7CLRD-33 5730~4040A19 45 NSE100N 3P 100AMALC1-D65M7C LC1-D38M7CLRD-33 5948~6547A20 55 NSE160N 3P 150AMALC1-D65M7C LC1-D38M7CLRD-33 5948~6558A21 75 NSE160N 3P 150AMALC1-D95M7C LC1-D50M7CLRD-33 6363~8078A22 90 NSE250N 3P 220AMALC1-D115M7C LC1-D65M7CLRD-43 6580~10499AABB电动机接触器与热继电器选型表序号功率断路器直接启动星三角启动备注接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 S263-D16 A9-30-10*80+CA5-22M TA25 DU1.0 0.56A2 0.37 S263-D16 A9-30-10*80+CA5-22M TA25 DU1.4 1.1A3 0.55 S263-D16 A9-30-10*80+CA5-22M TA25 DU1.8 1.5A4 0.75 S263-D16 A9-30-10*80+CA5-22M TA25 DU2.4 1.9A5 1.1 S263-D16 A9-30-10*80+CA5-22M TA25 DU4.0 2.8A6 1.5 S263-D16 A16-30-10*80+CA5-22TA25 DU5.0 3.5AM7 2.2 S263-D16 A12-30-10*80+CA5-22MTA25 DU6.5 5A 8 3 S263-D16 A26-30-10*80+CA5-22MTA25 DU8.5 6.6A 9 3.7 S263-D16 A30-30-10*80+CA5-22MTA25 DU11 8A 10 5.5 S263-D20A A30-30-10*80+CA5-22MTA25 DU14 12A11 7.5 S263-D25A A30-30-10*80+CA5-22MTA25 DU19 15A A30-30-10*80+CA5-22M A16-30-10*80+CA5-22M TA25 DU8.5 7A 12 9 S263-D25A A30-30-10*80+CA5-22 MTA42 DU25 18A A30-30-10*80+CA5-22M A16-30-10*80+CA5-22M TA25 DU8.5 9A 13 11 S263-D32AA30-30-10*80+CA5-22M TA42 DU25 22A A30-30-10*80+CA5-22M A16-30-10*80+CA5-22M TA25 DU14 11A 14 15T1N160 MA52 FFC 3PA40-30-10*80+CA5-22M TA42 DU3228.5A A40-30-10*80+CA5-22M A16-30-10*80+CA5-22MTA25 DU19 14A 15 18.5T1N160 MA52 FFC3P A50-30-11*80 A30-30-10*80+CA5-22MTA25 DU25 18A 16 22 T1N160 MA52 FFC3PA63-30-11*80 A30-30-10*80+CA5-22MTA25 DU32 26A 17 30 T1N160 MA80 FFC3PA75-30-11*80 A40-30-10*80+CA5-22MTA42 DU32 29A 18 37 T1N160 MA80 FFC3PA75-30-11*80 A40-30-10*80+CA5-22MTA75 DU52 40A 19 45T1N160 MA100 FFC3PA75-30-11*80 A40-30-10*80+CA5-22MTA75 DU63 47A 20 55 T1N160 MA100 FFCA75-30-11*80A40-30-10*80+CA5-22TA75 DU6358A3P M21 75 T3N250N MA160 FF3PA95-30-11*80 A50-30-11*80 TA110 DU90 78A22 90 T3N250N MA200 FF3PA110-30-11*80 A63-30-11*80 TA110 DU110 99A常熟富士电动机接触器与热继电器选型表序号功率断路器直接启动星三角启动备注接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 BC63E1DG-3P016 SC-E02 +SZ-A11TK-E02H-C0.0.48~0.720.56A2 0.3 BC63E1DG-3P016 SC-E02 +SZ-A11 TK-E02K-C0.8~1.21.1A3 0.4 BC63E1DG-3P016 SC-E02 +SZ-A11 TK-E02M-C1.4~2.21.5A4 0.75 BC63E1DG-3P016 SC-E02 +SZ-A11 TK-E02N-C1.7~2.61.9A5 1.1 BC63E1DG-3P016 SC-E02 +SZ-A11 TK-E02P-C2.2~3.42.8A6 1.5 BC63E1DG-3P016 SC-E02 +SZ-A11 TK-E02R-C2.8~4.23.5A7 2.2 BC63E1DG-3P016 SC-E02 +SZ-A11 TK-E02S-C 4~6 5A8 3 BC63E1DG-3P016 SC-E02 +SZ-A11 TK-E02T-C 5~8 6.6A9 3.7 BC63E1DG-3P016 SC-E03 +SZ-A11 TK-E02V-C7~118A10 5.5 BC63E1DG-3P016 SC-E03 +SZ-A11 TK-E02W-C 9~1312A11 7.5 BC63E1DG-3P020 SC-E04 +SZ-A11 TK-E02X-C 12~1815A SC-E03 +F4-11+SZ-A22 SC-E02 +F4-11+SZ-A11 TK-E02V-C7~117A12 9 BC63E1DG-3P025 SC-E05 +SZ-A11 TK-E02Q-C 16~2218A SC-E03 +F4-11+SZ-A22 SC-E02 +F4-11+SZ-A11 TK-E02W-C9~139A13 11 BC63E1DG-3P032 SC-E05 +SZ-A11 TK-E02Y-C 20~2522A SC-E04 +F4-11+SZ-A22 SC-E02 +F4-11+SZ-A11 TK-E02W-C9~1311A14 15 BW103E0 50 SC-E1 +SZ-A11 TK-E2E-C24~3628.5A SC-E05 +F4-11+SZ-A11 SC-E03 +F4-11+SZ-A11 TK-E02X-C12~1814A15 18.5 BW103E0 50 SC-E05 +F4-11+SZ-A22 SC-E04 +F4-11+SZ-A11 TK-E02Q-C16~2218A16 22 BW103E0 80 SC-E1 +F4-11+SZ-A22 SC-E04 +F4-11+SZ-A11 TK-E2E-C24~3626A17 30 BW103E0 80 SC-E2 +F4-11+SZ-A22 SC-E05 +F4-11+SZ-A11 TK-E2E-C24~3629A18 37 BW162E0 125A SC-E2S +F4-11+SZ-A22 SC-E05 +F4-11+SZ-A11 TK-E2H-C40~5040A19 45 BW162E0 150A SC-E3 +F4-11+SZ-A22 SC-E1 +F4-11+SZ-A11 TK-E3J-C45~6547A20 55 BW162E0 160A SC-E3 +F4-11+SZ-A22 SC-E2 +F4-11+SZ-A11 TK-E3J-C45~6558A21 75 BW253E0 225A SC-E5 +F4-11+SZ-AS2 SC-E3 +F4-11+SZ-A11 TK-E5M-C65~9578A22 90 BW253E0 250A SC-E5 +F4-11+SZ-AS2 SC-E3 +F4-11+SZ-A11 TK-E5I-C85~10599A常熟开关厂电动机接触器与热继电器选型表序号功率断路器直接启动星三角启动备注接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 I0.48-0.720.56A2 0.3 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 K0.8-1.21.1A3 0.4 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 M1.4-2.21.5A4 0.75 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 N1.7-2.61.9A5 1.1 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 P2.2-3.42.8A6 1.5 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 R2.8-4.23.5A7 2.2 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 T4~65A8 3 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 U6~96.6A9 3.7 CH1-63 D16/3 CK3-09+FSZ-A11 CJR3-25 V 7~11 8A10 5.5 CH1-63 D20/3 CK3-12+FSZ-A11 CJR3-25 W 9~13 12A11 7.5 CH1-63 D25/3 CK3-18+FSZ-A11 CJR3-25 X12~1815A CK3-18+FSZ-A11 CK3-12+FSZ-A11 CJR3-25 V 7~11 7A12 9 CH1-63 D25/3 CK3-25+FSZ-A11 CJR3-25 Q16~2218A CK3-18+FSZ-A11 CK3-12+FSZ-A11 CJR3-25 W 9~13 9A13 11 CH1-63 D32/3 CK3-25+FSZ-A11 CJR3-25 Y20~2522A CK3-18+FSZ-A11 CK3-12+FSZ-A11 CJR3-25 W 9~13 11A14 15 CM1-63L3300 63A CK3-32 CJR3-50 E24~3628.5A CK3-25+FSZ-A11 CK3-12+FSZ-A11CJR3-25 X12~1814A15 18.5 CM1-63L3300 63A CK3-25+FSZ-A11 CK3-12+FSZ-A11 CJR3-25 Q16~2218A16 22 CM1-100L3300 80A CK3-32 CK3-18+FSZ-A11 CJR3-50E24~3626A17 30 CM1-100L3300 80A CK3-40 CK3-18+FSZ-A11 CJR3-50 E24~3629A18 37 CM1-160L3300125ACK3-50 CK3-25+FSZ-A11CJR3-50 H40~5040A19 45 CM1-160L3300140ACK3-65 CK3-32CJR3-105B O48~6847A20 55 CM1-160L3300160ACK3-65 CK3-32CJR3-105B O48~6858A21 75 CM1-225L3300225ACK3-80 CK3-50CJR3-105B M65-9578A22 90 CM1-250L3300250ACK3-105 CK3-65CJR3-105 I85~10599A士林电动机接触器与热继电器选型表序号功率断路器直接启动星三角启动备注接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 BHA33D16A S-P12 TH P12 0.6~1 0.56A2 0.3 BHA33D16A S-P12 TH P12 0.6~1 0.9A3 0.4 BHA33D16A S-P12 TH P12 1~1.6 1.2A4 0.75 BHA33D16A S-P12 TH P12 1.6~2.4 1.7A5 1.1 BHA33D16A S-P12 TH P12 2.4~4 2.1A6 1.5 BHA33D16A S-P12 TH P12 2.4~4 3.0A7 2.2 BHA33D16A S-P12 TH P12 4~6 4.6A8 3 BHA33D16A S-P12 TH P12 6~9 7A9 3.7 BHA33D16A S-P12 TH P12 7~11 8A10 5.5 BHA33D20A S-P16 TH P12 9~13 12A11 7.5 BHA33D25A S-P21 TH P12 12~18 15A S-P21 S-P11 TH P20 6~9 7A12 9 BM60SN 3P 40A S-P25 TH P20 17~24 18A S-P21 S-P11 TH P20 7~11 9A13 11 BM60SN 3P 50A S-P25 TH P20 22~34 21A S-P21 S-P11TH P20 9~13 11A14 15 BM60SN 3P 50A S-P35T TH P20 22~34 28A S-P21 S-P11 TH P20 12~18 14A15 18.5 BM60SN 3P 50A S-P21 S-P11 TH P20 17~24 18A16 22 BM100SN 3P 75A S-P35T S-P16 TH P20 22~34 21A17 30 BM100SN 3P 100A S-P35T S-P16 TH P20 28~38 29A18 37 BM100SN 3P 100A S-P50T S-P21 TH P60 32~48 35A19 45 BM160SN 3P 125A S-P50T S-P21 TH P60 43~65 43A20 55 BM250SN 3P 200A S-P60T S-P21 TH P60 54~80 52A21 75 BM250SN 3P 225A S-P80T S-P35 TH P60 60~100 71A22 90 BM250SN 3P 250A S-P100T S-P50 TH P120 80~130 85A三菱电动机接触器与热继电器选型表序号功率断路器直接启动星三角启动备注接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 BH-D6 3P D16A S-V12+UN-AX11TH-N12KP0.55~0.850.56A2 0.3 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP 0.9A0.7~1.13 0.4 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP1.0~1.61.2A4 0.75 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP1.4~21.7A5 1.1 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP1.7~2.52.1A6 1.5 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP2.8~4.43.0A7 2.2 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP 4~6 4.6A8 3 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP5.2~87A9 3.7 BH-D6 3P D16A S-V12+UN-AX11 TH-N12KP7~118A10 5.5 BH-D6 3P D20A S-V12+UN-AX11 TH-N12KP9~1312A11 7.5 BH-D6 3P D25A S-V18+UN-AX11 TH-N18 12~18 15A S-V18+UN-AX11 S-V12+UN-AX11 TH-N12KP5.2~87A12 9 BH-D6 3P D32A S-V25 TH-N20TAKP18~2618A S-V18+UN-AX11 S-V12+UN-AX11TH-N12KP7~119A13 11 NF63-SW 3P 40A S-V25 TH-N20TAKP18~2621A S-V18+UN-AX11 S-V12+UN-AX11TH-N20KP9~1311A14 15 NF63-SW 3P 50A S-V32 TH-N20TAKP24~3427A S-V25 S-V12+UN-AX11TH-N20KP12~1814A15 18.5 NF63-SW 3P 50A S-V25 S-V12+UN-AX11 TH-N20TAKP18~2618A16 22 NF125-SW 3P 80A S-V40 S-V18 TH-N20TAKP18~2620A17 30 NF125-SW 3P 80A S-V40 S-V18 TH-N20TAKP24~3429A18 37 NF125-SW 3P100A S-V50 S-V25 TH-N20TAKP30~4035A19 45 NF125-SW 3P125A S-V50 S-V25 TH-N60KP34~5043A20 55 NF250-SW 3P200A S-N65 S-V40 TH-N60KP43~6552A21 75 NF250-SW 3P225A S-N95 S-V50 TH-N60TAKP65~10071A22 90 NF250-SW 3P250A S-N125 S-N65 TH-N120TAKP85~12585A正泰电动机接触器与热继电器选型表序号功率断路器直接启动星三角启动备注接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 DZ47-60 3P D16A CJX2-09 +F4-11 NR2-11.50.63~1A0.56A2 0.37 DZ47-60 3P D16A CJX2-09 +F4-11 NR2-11.51~1.6A1.1A3 0.55 DZ47-60 3P D16A CJX2-09 +F4-11 NR2-11.51.6~2.5A1.5A4 0.75 DZ47-60 3P D16A CJX2-09 +F4-11 NR2-11.51.6~2.5A2A5 1.1 DZ47-60 3P D16A CJX2-09 +F4-11 NR2-11.52.5~4A2.8A6 1.5 DZ47-60 3P D16A CJX2-09 +F4-11 NR2-11.52.5~4A3.7A7 2.2 DZ47-60 3P D16A CJX2-12 +F4-11 NR2-11.5 4~6 5.3A8 3 DZ47-60 3P D16A CJX2-18 +F4-11 NR2-11.55.5~87A9 3.7 DZ47-60 3P D16A CJX2-18 +F4-11 NR2-11.5 7~10 8A10 5.5 DZ47-60 3P D20A CJX2-18 +F4-11 NR2-11.5 9~13 12A11 7.5 DZ47-60 3P D25A CJX2-25 +F4-11 NR2-25 12~18 15A CJX2-18 +F4-22 CJX2-12 +F4-11 NR2-11.55.5~87A12 9 DZ47-60 3P D25A CJX2-25 +F4-11 NR2-25 17~25 18A CJX2-18 +F4-22 CJX2-12 +F4-11 NR2-11.5 7~10 9A13 11 DZ47-60 3P D32A CJX2-32 +F4-11 NR2-25 17~25 23A CJX2-18 +F4-22 CJX2-12 +F4-11 NR2-11.5 9~13 11A14 15 NM1-63S 3P 40A CJX2-40 JR36-63 28~45 30A CJX2-18 +F4-22 CJX2-18 +F4-11 JR36-20 10~16 14A15 18.5 NM1-63S 3P 63A CJX2-32 +F4-22 CJX2-18 +F4-11 JR36-20 14~22 18A16 22 NM1-100S 3P 80A CJX2-40 08(2NO2NC) CJX2-25 +F4-11 JR36-63 20~32 26A17 30 NM1-100S 3P 100A CJX2-50 8(2NO2NC) CJX2-25 +F4-11 JR36-63 28~45 29A18 37 NM1-100S 3P 100A CJX2-50 08(2NO2NC) CJX2-32 +F4-11 JR36-63 28~45 40A19 45 NM1-225S 3P 160A CJX2-65 08(2NO2NC) CJX2-32 +F4-11 JR36-63 40~63 47A20 55 NM1-225S 3P 160A CJX2-80 08(2NO2NC) CJX2-4008(2NO2NC) JR36-63 40~63 58A21 75 NM1-225S 3P 225A CJX2-95 08(2NO2NC) CJX2-50 08(2NO2NC) JR36-16053~8578A22 90 NM1-400S 3P 315A CJ20-160 CJX2-80 08(2NO2NC) JR36-16075~12099A德力西电动机接触器与热继电器选型表序功率断路器直接启动星三角启动备注号接触器热继电器整定值接触器*2 接触器热继电器整定值1 0.15 DZ47-60 3P D16A CJX2-09 +F4-11 JRS1-250.63~1A0.56A2 0.37 DZ47-60 3P D16A CJX2-09 +F4-11 JRS1-251~1.6A1.1A3 0.55 DZ47-60 3P D16A CJX2-09 +F4-11 JRS1-251.6~2.5A1.5A4 0.75 DZ47-60 3P D16A CJX2-09 +F4-11 JRS1-251.6~2.5A2A5 1.1 DZ47-60 3P D16A CJX2-09 +F4-11 JRS1-252.5~4A2.8A6 1.5 DZ47-60 3P D16A CJX2-09 +F4-11 JRS1-252.5~4A3.7A7 2.2 DZ47-60 3P D16A CJX2-12 +F4-11 JRS1-25 4~6 5.3A8 3 DZ47-60 3P D16A CJX2-18 +F4-11 JRS1-25 55.5~87A9 3.7 DZ47-60 3P D16A CJX2-18 +F4-11 JRS1-257~108A10 5.5 DZ47-60 3P D20A CJX2-18 +F4-11 JRS1-2510~1312A11 7.5 DZ47-60 3P D25A CJX2-25 +F4-11 JRS1-25 13~18 15A CJX2-18 +F4-22 CJX2-12 +F4-11 JRS1-25 55.5~87A12 9 DZ47-60 3P D25A CJX2-25 +F4-11 JRS1-25 18~25 18A CJX2-18 +F4-22 CJX2-12 +F4-11 JRS1-257~109A13 11 DZ47-60 3P D32A CJX2-32 +F4-11 JRS1-25 18~25 23A CJX2-18 +F4-22 CJX2-12 +F4-11 JRS1-2510~1311A14 15 CDM1-63S 3P 40A CJX2-40 JR36-63 30~40 30A CJX2-18 +F4-22 CJX2-18 +F4-11 JR36-20 10~16 14A15 18.5 CDM1-63S 3P 63A CJX2-32 +F4-22 CJX2-18 +F4-11 JR36-20 14~22 18A16 22 CDM1-100S 3P 80A CJX2-40 +F4-22 CJX2-25 +F4-11JR36-63 20~32 26A17 30 CDM1-100S 3P100ACJX2-50 +F4-22 CJX2-25 +F4-11 JR36-63 28~45 29A18 37 CDM1-100S 3P100ACJX2-50 +F4-22 CJX2-32 +F4-11 JR36-63 28~45 40A19 45 CDM1-225S 3P160ACJX2-65 +F4-22 CJX2-32 +F4-11 JR36-63 40~63 47A20 55 CDM1-225S 3P160ACJX2-80 +F4-22 CJX2-40 08(2NO2NC) JR36-63 40~63 58A21 75 CDM1-225S 3P225ACJX2-95 +F4-22 CJX2-50 08(2NO2NC)JR36-16053~8578A22 90 CDM1-400S 3P315ACJX2-150 +F4-22 CJX2-80 08(2NO2NC)JR36-16075~12099A。

abb接触器参数说明

abb接触器参数说明

abb接触器参数说明摘要:1.ABB接触器简介2.ABB接触器参数说明a.额定电压b.额定电流c.额定功率d.工作制种类e.使用类别3.ABB接触器型号及含义4.ABB接触器的应用领域5.ABB接触器优势与特点正文:ABB接触器是一种广泛应用于建筑业和工业领域的电气控制设备。

它主要用于电机控制、保暖和通风、空调、水泵、提升设备、照明和校正功率因数等方面。

ABB接触器参数包括额定电压、额定电流、额定功率、工作制种类和使用类别等。

1.ABB接触器简介ABB接触器是ABB公司生产的一款接触器产品,具有较高的品质和性能。

接触器是一种开关设备,主要用于控制电路的接通和断开。

它具有体积小、性能稳定、操作方便等特点。

2.ABB接触器参数说明ABB接触器的参数主要包括额定电压、额定电流、额定功率、工作制种类和使用类别等。

a.额定电压:接触器铭牌上的额定电压是指主触点上的额定电压。

通常用的电压等级有直流接触器和交流接触器,如127V、220V、380V、500V等。

b.额定电流:接触器铭牌上的额定电流是指主触点的额定电流。

直流接触器的额定电流有25A、40A、60A、100A、250A、400A、600A等;交流接触器的额定电流有5A、10A、20A、40A、60A、100A、150A、250A、400A、600A等。

c.额定功率:接触器的额定功率是指在额定电压下,接触器能承受的最大功率。

通常,额定功率与额定电压和额定电流有关。

d.工作制种类:接触器的工作制种类包括连续工作制、断续工作制和短时工作制等。

不同的工作制种类对接触器的使用寿命和性能有影响。

e.使用类别:接触器的使用类别包括通用接触器、高性能接触器和特殊性能接触器等。

不同类别的接触器适用于不同的应用场景。

3.ABB接触器型号及含义ABB接触器的型号通常由数字和字母组成,如T1、T2、T3等。

每个型号都代表不同的接触器类型和参数。

通过型号,可以快速了解接触器的性能和特点。

ABB接触器资料

ABB接触器资料
询熔断器的选型手册。 (3) 为保证电气寿命,必须遵照安装手册
上的维护程序。 (4) 该电流值由熔断器和接触器的时间—
电流脱扣曲线的交点决定。 (5) 应加装避雷器等防止过电压设备。 (6) 如有特殊要求,请与厦门ABB 开关有
限公司咨询。
6
2 接触器选择和订货
标准配置
1. MAC 永磁操动机构用储能电容( 1b )。 2. 辅助触点:
20...30 35...45 49
371 350 215
636 531 657
3.6/5 1,500 2,000 1,500
250 8 2.5
VSC 12 400 A - VSC/P 12 400A
接触器
起动器
3.4.105
12 42 75 50-60 400 6,000 15 1 -
3.4.110
20...30 35...45 20 49
371 350 215
636 531 657
400 100,000 1,000,000 1,000,000 C 6,000 15,000 -
20...30 35...45 20 49
371 350 215
636 531 657
VSC 7 - 400A 2.2/2.5 1,000 1,100 1,000
ABB 凭借在中压真空断路器中使用“ MABS ”型永磁操 动机构取得的成功经验,开发出了性能更优异的中压接 触器用双稳态“ MAC ”型永磁操动机构。
永磁操动机构由宽电源稳压模块供电。不同的电源模块 可根据功能模块及辅助电源电压的要求选择。
电源电压可以选择在其工作频率下允许范围内的任意值。
可选型号
供电模块类型 1 (24 ... 60 DC)

ABB接触器 产品简介

ABB接触器 产品简介
電壓 ... V - 50 Hz
24 48 110 220 ... 230 230 ... 240 380 ... 400 400 ... 415
電壓 ... V - 60 Hz
24 48 110 ... 120 230 ... 240 240 ... 260 400 ... 415 415 ... 440
A40-30-10 A40-30-01 A50-30-11 A63-30-11 A75-30-11 A95-30-11 A110-30-11
常開 (NO)
1 0 1 0 1 0 1 0 1 0
1 0 1 1 1 1 1
常閉 (NC)
0 1 0 1 0 1 0 1 0 1
0 1 1 1 1 1 1
線圈電壓:
11
50
65
75
15
18.5
22
380 - 400V
4
操作頻率 (AC-3) 每小時
線圈操作範圍
線圈功耗 吸合
50Hz VA
保持
VA/W
5.5
7.5
11
15**
18.5
22
30
37
1200
0.85 - 1.1Uc
70 8/2
120 12 / 3
180 18 / 5.5
A95 A110
145
160
98
0.10...0.16 0.16...0.25 0.25...0.4
0.4 ...0.63 0.63 ...1.0 1.0 ...1.4 1.3 ...1.8 1.7 ...2.4
2.2...3.1 2.8...4.0 3.5...5.0 4.5...6.5 6.0...8.5

ABB接触器A30-30-10

品牌:ABB 型号:A30-30-10主触头:3A 辅助触头:1AABB接触器的规格包括4 和5.5KW 的微型辅助触头:1B接触器、高达400kW 的接触器组(AC3),建筑用接触器(家用和工业用),拍合式接触器,热过载继电器和电子继电器,以及完整的附件,确保选择灵活性和满足客户需求。

ABB系列交流接触器用于交流50Hz 或60Hz,额定绝缘电压为690-1000V,在AC-3 使用类别下额定工作电压为380V 时的额定工作电流为9A-400A。

AF400-30-11 200kW线圈电压:48-130/110-250/250-500。

主要供远距离接通及分断电路之用,适用于控制交流电动机的起动、停止及反转。

符合IEC947,VDE0660,GB14048-0577********-136********等标准。

主要结构及工作原理接触器为正装直动式双断点结构,罩盖与躯壳采用耐弧塑料制成,A 9-A16采用自动灭弧,而A26-A110有U型的灭弧片置于躯壳中,形成封闭灭弧室灭弧好,飞弧距离为零。

触头采用抗熔焊及耐电磨损的银基合金材料制成,导电性能好,寿命长,对环境无污染。

铁芯采用E形结构,体积小。

线圈的接线方式有两种可供用户选择,一种两接线端在产品的同一端,另一种两接线端分别在产品的两端,接线灵活方便。

底座用玻璃纤维增强塑料制成,强度高,介电性能好。

安装方式可以螺钉安装,也可以用导轨安装,拆装方便迅速。

导电部件不外露,安全性能好。

正常工作条件和安装条件1、安装地点的海拔不超过2000M。

2、周围空气温度不超过+40度,且其25H内的平均温度值不超过= 35度,周围空气温度下限值为-5度。

3、安装地点的空气相对温度在最高+40度时不超过50%,在较低温度时可允许有较高的相对温度,例如20度时达90%,对由于温度变化偶尔产生的凝露应采取特殊措施。

4、安装地点的污染等级为3级。

5、接触器允许垂直或水平安装,当垂直安装时,安装而与垂直的倾斜度不大于正负30%。

abb接触器参数说明

abb接触器参数说明(最新版)目录1.ABB 接触器的概念与应用领域2.ABB 接触器的型号与参数3.ABB 接触器的参数说明4.ABB 接触器的使用注意事项5.结束语正文一、ABB 接触器的概念与应用领域ABB 接触器是一种电气控制元件,主要用于建筑业和工业领域,如电机控制、保暖和通风、空调、水泵、提升设备、照明和校正功率因数等。

它通过主触点接通或分断电路,实现对电路的控制。

二、ABB 接触器的型号与参数ABB 接触器的型号大全涵盖了多种规格,包括 4、5.5kW 的微型接触器和高达 400kW 的接触器。

接触器的参数包括额定电压、额定电流、额定工作电压等。

例如,某负载是 380V 的三相感应电动机,则应选 380V 的交流接触器。

三、ABB 接触器的参数说明1.额定电压:接触器铭牌额定电压是指主触点上的额定电压。

通常用的电压等级为:直流接触器为 110V、220V、440V、660V 等档次;交流接触器为 127V、220V、380V、500V 等档次。

2.额定电流:额定电流接触器铭牌额定电流是指主触点的额定电流。

直流接触器的额定电流为 25A、40A、60A、100A、250A、400A、600A;交流接触器的额定电流为 5A、10A、20A、40A、60A、100A、150A、250A、400A、600A。

四、ABB 接触器的使用注意事项在使用 ABB 接触器时,应注意以下几点:1.根据负载的电压、电流等参数选择合适的接触器型号。

2.接触器应安装在通风、干燥、无腐蚀性气体的环境中,避免阳光直射和雨淋。

3.接线时应确保线径与接触器额定电流相匹配,并正确连接主触点和辅助触点。

4.接触器操作频率不宜过高,以免影响其使用寿命。

5.定期检查接触器的工作状态,发现异常应及时处理。

五、结束语总之,ABB 接触器作为一款优秀的电气控制元件,在多个应用领域发挥着重要作用。

电动机接触器与热继选型表


SC-E02 +F4-11+SZA11
SC-E02 +F4-11+SZA11
SC-E02 +F4-11+SZA11
SC-E03 +F4-11+SZA11
SC-E04 +F4-11+SZA11
SC-E04 +F4-11+SZA11
SC-E05 +F4-11+SZA11
SC-E05 +F4-11+SZA11
16 22 T1N160 MA52 FFC 3P
17 30 T1N160 MA80 FFC 3P
18 37 T1N160 MA80 FFC 3P
19 45 T1N160 MA100 FFC 3P
20 55 T1N160 MA100 FFC 3P
21 75 T3N250N MA160 FF 3P
ห้องสมุดไป่ตู้
22 90 T3N250N MA200 FF 3P
LRD-43 65 80~104 99A
备注
ABB电动机接触器与热继电器选型表
序 号
功率
1 0.15 2 0.37 3 0.55 4 0.75 5 1.1 6 1.5 7 2.2 83 9 3.7 10 5.5 11 7.5 12 9 13 11 14 15 15 18.5
断路器
S263-D16 S263-D16 S263-D16 S263-D16 S263-D16 S263-D16 S263-D16 S263-D16 S263-D16 S263-D20A S263-D25A S263-D25A S263-D32A T1N160 MA52 FFC 3P T1N160 MA52 FFC 3P

ABB常用型号说明

ABB常用型号说明2009-12-06 11:43针对现在有很多业务员反映看不懂ABB面价表,里面的型号有很多相似之处,客户又没特殊要求,常用的型号根本不知道怎么选。

在此,特对我们最常用型号做如下说明及订货输入方式。

一、接触器1、选型必要参数:清楚电流大小,极数,触点方式及工作电压,就可以选型。

如额定工作电流为110A,主回路3极,1常开1常闭,工作电压是220V。

则可以选型为A110-30-11 AC220V2、如何在面价表中查询:我们在04年ABB低压产品面价表中工作电压为220V的正确型号也是最常用的型号应该为A110-30-11*220-230V50HZ,所以在面价表中选接触器时,都要以这样的型号为准,除客户特殊要求。

我们库存型号如:A110-30-11 AC220V,这个型号就是面价表中的A110-30-11*220-23050HZ,现在出现业务员订A110-30-11*220V50HZ,可能就会看到为什么处理的货期这么长,220V的不是很常用的吗?我们的解释是,这是两个完全不同的型号,你已经订错货了,此为不常用型号。

所以请各位在选型时看清楚常用型号,如果是要220V,就必须在价格表中找220-230V50HZ的,以免订错货物承担库存。

以下是交流接触器在面价表中的几个电压等级正确型号:24V————A110-30-11*24V50HZ110V————A110-30-11*110-115V50HZ220V-------A110-30-11*220-23050HZ380V————A110-30-11*380-400V50HZ3、订货输入要求:型号输入:A110-30-11 AC220V型号就这样输入,但品名必须要输入220-230V所对应的物料号,虽然我们没有输入220-230V,但物料号一定不能错。

要和自己订的型号完全一致。

二、热过载继电器1、过载继电器在价格表中如TA25DU1.0和TA25DU1.0 V1000,同是1.0的就有两个型号,就纳闷了,我到底应该选哪个呢,导致无法确认?现在明确的说明,选TA25DU1.0,所有的热继都不要去管带V1000的,包括我们库存型号也是一样的。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档