MA5600机柜系统介绍

合集下载

华为EPON设备介绍

华为EPON设备介绍

一、EPON技术介绍.......................................................................................... 错误!未定义书签。

二、硬件介绍................................................................................................... 错误!未定义书签。

1 MA5680T业务框外观如所示......................................................... 错误!未定义书签。

2 MA5606T的外观与尺寸................................................................. 错误!未定义书签。

3 MA5620E的外观与尺寸................................................................. 错误!未定义书签。

4 MA5616的外观与尺寸 ................................................................... 错误!未定义书签。

二、业务配置过程........................................................................................... 错误!未定义书签。

1组网图............................................................................................... 错误!未定义书签。

2业务配置流程................................................................................... 错误!未定义书签。

华为产品全览--边缘层接入设备-华为(第一版)

华为产品全览--边缘层接入设备-华为(第一版)

MSAN&MSAG边缘层接入设备: 多业务综合接入系统 HONET UA5000边缘层接入设备: 小容量室内型盒式综合接入设备 HUAWEI ONU-60A边缘层接入设备: 室内型中规格综合接入设备HONET UA5000边缘层接入设备: 室内型大容量AG接入设备HONET AMG5000边缘层接入设备: 室内型小容量AG接入设备HONET AMG5160局端DSLAM边缘层接入设备: SmartAX MA5600边缘层接入设备: SmartAX MA5300边缘层接入设备: SmartAX MA5100XPON汇聚型OLT设备SmartAX MA5680T接入设备系列化接入终端HG810e HG813e HG850e HG810 HG850 OT925G接入节点及其光配线网(ODN)光纤配线架(ODF)光缆交接箱光分路单元光缆接头盒分纤盒终端盒入户终端盒弱电箱网络箱光缆系列管材接入网管理系统MSAN随着用户对电信业务的需求与日俱增,提供大容量、高速率、高质量的综合业务(语音、数据、视频和多媒体等)成为接入网发展的方向。

电信网正朝着智能化、宽带化、综合化的方向迈进,运营商已经建立了较完善的骨干网络,如何实现接入层设备的有效建设是当前网络建设关注的重点,这就需要有一种可以快速实现宽窄带一体化接入,并具有平滑演进能力的接入层产品。

华为HONET多业务综合接入系统顺应了接入网发展的方向,满足传统语音业务、VoIP业务、数据专线业务、宽带业务和视频业务的混合接入需求。

截至2007年3季度,华为综合接入产品已经向全球60个国家和地区销售了超过8300万端口, 产品销往英国、西班牙、新加坡、俄罗斯、埃及、沙特阿拉伯、巴西和中国等地,市场份额超过45%,成为MSAN名符其实的全球第一品牌。

为适应各种不同的应用场景,HONET 多业务综合接入系统推出了系列化的产品规格。

MSAN&MSAG 多业务综合接入系统 HUAWEI HONET UA5000UA5000采用先进的融合平台设计,支持V5、H.248/MGCP、内部协议,提供GE/FE/E1上行,可作为综合AG、V5综合接入、交换机综合模块设备。

MA5600硬件介绍与系统原理

MA5600硬件介绍与系统原理
5
华为机密,未经许可不得扩散 文档密级:内部公开
全GE宽带接入平台:MA5600宽带接入航母
SCU
xDSL LAN FTTH
GE N×GE上行 GE 全GE交换网 N×GE 全GE交换网
XDSL
增值业务 处理板
用户板
大容量
控制交换框/母局
N×GE 内部星型链路
模块化
综合化
LAN WiMax
SCU xDSL
RN U AL M
(1) (2) (3) (4) (5)
RESET
组网管理.
(7)
提供端口:
丰富的
(6)
FE/GE 接口, 8×FE or 4×FE+
2×GE
HUAWEI
21
华为机密,未经许可不得扩散 文档密级:内部公开
SCU-ISU 背板内部tEthernet

ITU-G.991.2

ITU-G.991.2 Annex A
北美标准


ITU- G.991.2 Annex
提供维护串口与网口。 支持主控板主备倒换功能。 提供环境监控接口,用于连接环境监控模块。
SPL
H ET
(8)
0
HUAWEI
提供接口 :
维护接口:
ETH,CON, MON
15
丰 富 的 FE/GE 接 口 :
6×FE / 6×GE / 1/2×GE + 4×FE / 2×FE + 4×GE
文档密级:内部公开
13
系统总线图
S C U S C U
GE BUS
A D E F
A D B F
S H E A
E I U

MOXA NPort 5600系列19英寸柜架串行设备服务器特性与优势说明书

MOXA NPort 5600系列19英寸柜架串行设备服务器特性与优势说明书

NPort5600Series8and16-port RS-232/422/485rackmount serial device serversFeatures and Benefits•Standard19-inch rackmount size•Easy IP address configuration with LCD panel(excluding wide-temperaturemodels)•Configure by Telnet,web browser,or Windows utility•Socket modes:TCP server,TCP client,UDP•SNMP MIB-II for network management•Universal high-voltage range:100to240VAC or88to300VDC•Popular low-voltage ranges:±48VDC(20to72VDC,-20to-72VDC)CertificationsIntroductionWith the NPort®5600Rackmount Series,you not only protect your current hardware investment,but also allow for future network expansion by centralizing the management of your serial devices and distributing management hosts over the network.Network Readiness for up to16Serial DevicesOnly basic configuration is needed with the NPort®5600to connect up to16serial devices to an Ethernet network.19-Inch Rackmount Device ServerNPort®5600device servers come with Tx/Rx LEDs for the serial ports on the front panel,and8or16RJ45serial port connectors on the rear panel. This makes the NPort®5600device servers suitable for a standard19-inch rackmount,allowing you to simplify operational,maintenance,and administrative tasks.Real COM/TTY PortsReal COM/TTY drivers are provided to make the serial ports on the NPort®5600recognizable as Real COM ports by Windows,or Real TTY ports by Linux.In addition to supporting basic data transmission and reception,the NPort®drivers also support the RTS,CTS,DTR,DSR,and DCD control signals.LED Indicators to Ease Your Maintenance TasksThe System LED,serial Tx/Rx LEDs,and Ethernet LEDs(located on the RJ45connector)provide a great tool for basic maintenance tasks and help engineers analyze problems in the field.The LEDs not only indicate current system and network status,but they also help field engineers monitor the status of attached serial devices.Adjustable Termination and Pull High/Low ResistorsWhen using termination resistors to prevent serial signal reflection,itis important to set the pull high/low resistors correctly so that theelectrical signal is not corrupted.Since no set of resistor values isuniversally compatible for all environments,the NPort®5650-8/16has DIP switches on the bottom panel for setting the termination andpull high/low resistor values.AppearanceSpecificationsEthernet Interface10/100BaseT(X)Ports(RJ45connector)1Magnetic Isolation Protection 1.5kV(built-in)Optical Fiber100BaseFXMulti-Mode Single-ModeFiber Cable Type OM150/125µmG.652 800MHz x kmTypical Distance4km5km40kmWavelength Typical(nm)13001310TX Range(nm)1260to13601280to1340 RX Range(nm)1100to16001100to1600Optical Power TX Range(dBm)-10to-200to-5 RX Range(dBm)-3to-32-3to-34 Link Budget(dB)1229 Dispersion Penalty(dB)31Note:When connecting a single-mode fiber transceiver,we recommend using anattenuator to prevent damage caused by excessive optical power.Note:Compute the“typical distance”of a specific fiber transceiver as follows:Linkbudget(dB)>dispersion penalty(dB)+total link loss(dB).Ethernet Software FeaturesConfiguration Options Telnet Console,Web Console(HTTP/HTTPS),Windows UtilityManagement ARP,BOOTP,DHCP Client,DNS,HTTP,HTTPS,ICMP,IPv4,LLDP,RFC2217,Rtelnet,PPP,SLIP,SMTP,SNMPv1/v2c,TCP/IP,Telnet,UDPFilter IGMP v1/v2cWindows Real COM Drivers Windows95/98/ME/NT/2000,Windows XP/2003/Vista/2008/7/8/8.1/10(x86/x64),Windows2008R2/2012/2012R2(x64),Windows Embedded CE5.0/6.0,Windows XPEmbeddedFixed TTY Drivers SCO UNIX,SCO OpenServer,UnixWare7,QNX4.25,QNX6,Solaris10,FreeBSD,AIX5.x,HP-UX11i,Mac OS XLinux Real TTY Drivers Kernel version:2.4.x,2.6.x,3.x,4.xAndroid API Android3.1.x and laterTime Management SNTPSerial InterfaceConnector8-pin RJ45No.of Ports8or16portsSerial Standards NPort5610Series:RS-232NPort5630Series:RS-422,RS-485NPort5650Series:RS-232,RS-422,RS-485Operation Modes Disabled,Ethernet Modem,Pair Connection,Real COM,Reverse Telnet,RFC2217,TCPClient,TCP Server,UDPBaudrate Supports standard baudrates(unit=bps):50,75,110,134,150,300,600,1200,1800,2400,4800,7200,9600,19200,38400,57600,115200,230.4k,460.8k,921.6kData Bits5,6,7,8Stop Bits1,1.5,2Parity None,Even,Odd,Space,MarkFlow Control None,RTS/CTS(RS-232only),DTR/DSR(RS-232only),XON/XOFFPull High/Low Resistor for RS-4851kilo-ohm,150kilo-ohmsTerminator for RS-485120ohmsRS-485Data Direction Control ADDC®(automatic data direction control)Serial SignalsRS-232TxD,RxD,RTS,CTS,DTR,DSR,DCD,GNDRS-422Tx+,Tx-,Rx+,Rx-,GNDRS-485-4w Tx+,Tx-,Rx+,Rx-,GNDRS-485-2w Data+,Data-,GNDPower ParametersInput Current NPort5610-8-48V/16-48V:135mA@48VDCNPort5650-8-HV-T/16-HV-T:152mA@88VDCNPort5610-8/16:141mA@100VACNPort5630-8/16:152mA@100VACNPort5650-8/8-T/16/16-T:158mA@100VACNPort5650-8-M-SC/16-M-SC:174mA@100VACNPort5650-8-S-SC/16-S-SC:164mA@100VACInput Voltage HV Models:88to300VDCAC Models:100to240VAC,47to63HzDC Models:±48VDC,20to72VDC,-20to-72VDCReliabilityAutomatic Reboot Trigger Built-in WDTPhysical CharacteristicsHousing MetalInstallation19-inch rack mountingDimensions(with ears)480x45x198mm(18.90x1.77x7.80in)Dimensions(without ears)440x45x198mm(17.32x1.77x7.80in)Weight NPort5610-8:2,290g(5.05lb)NPort5610-8-48V:3,160g(6.97lb)NPort5610-16/5630-16:2,490g(5.49lb)NPort5610-16-48V:3,260g(7.19lb)NPort5650-8/5650-8-T:2,310g(5.09lb)NPort5650-8-M-SC:2,380g(5.25lb)NPort5650-8-S-SC/5650-16-M-SC:2,440g(5.38lb)NPort5650-8-HV-T:3,720g(8.20lb)NPort5650-16/5650-16-T:2,510g(5.53lb)NPort5650-16-S-SC:2,500g(5.51lb)NPort5650-16-HV-T:3,820g(8.42lb)Interactive Interface LCD panel display(standard temp.models only)Push buttons for configuration(standard temp.models only) Environmental LimitsOperating Temperature Standard Models:0to60°C(32to140°F)Wide Temp.Models:-40to75°C(-40to167°F)High-Voltage Wide Temp.Models:-40to85°C(-40to185°F) Storage Temperature(package included)Standard Models:-20to70°C(-4to158°F)Wide Temp.Models:-40to75°C(-40to185°F)High-Voltage Wide Temp.Models:-40to85°C(-40to185°F) Ambient Relative Humidity5to95%(non-condensing)Standards and CertificationsEMI CISPR32,FCC Part15B Class AEMC EN55032/24EMS NPort5650-8/16Series:IEC61000-4-2ESD:Contact:8kV;Air:15kVIEC61000-4-3RS:80MHz to1GHz:10V/mIEC61000-4-4EFT:Power:4kV;Signal:2kVIEC61000-4-5Surge:Power:2.5kV;Signal:1kVIEC61000-4-6CS:150kHz to80MHz:3V/m;Signal:3V/mIEC61000-4-8IEC61000-4-11DIPsNPort5650-8/16-HV Series:IEC61000-4-2ESD:Contact:4kV;Air:8kVIEC61000-4-3RS:80MHz to1GHz:3V/mIEC61000-4-4EFT:Power:4kV;Signal:2kVIEC61000-4-5Surge:Power:2kVIEC61000-4-6CS:150kHz to80MHz:3V/m;Signal:3V/mIEC61000-4-8Medical EN60601-1-2Class B,EN55011Safety UL60950-1MTBFTime NPort5610-8:877,888hrsNPort5610-8-48V:870,961hrsNPort5610-16:666,105hrsNPort5610-16-48V:662,111hrsNPort5630-8:765,449hrsNPort5630-16:473,748hrsNPort5650-8:692,010hrsNPort5650-8-T:692,010hrsNPort5650-8-HV-T:627,078hrsNPort5650-8-M-SC:678,053hrsNPort5650-8-S-SC:678,053hrsNPort5650-16:473,748hrsNPort5650-16-T:473,748hrsNPort5650-16-HV-T:442,626hrsNPort5650-16-M-SC:467,180hrsNPort5650-16-S-SC:467,180hrsStandards AC models:MIL-HDBK-217FHV models:Telcordia(Bellcore)Standard TR/SR WarrantyWarranty Period5yearsDetails See /warrantyPackage ContentsDevice1x NPort5600Series device serverInstallation Kit1x rack-mounting kitCable1x power cord,suitable for your region(AC models) Documentation1x document and software CD1x quick installation guide1x warranty cardDimensionsOrdering InformationNPort5610-88-pin RJ45RS-23280to60°C100-240VAC NPort5610-8-48V8-pin RJ45RS-23280to60°C±48VDC NPort5630-88-pin RJ45RS-422/48580to60°C100-240VAC NPort5610-168-pin RJ45RS-232160to60°C100-240VAC NPort5610-16-48V8-pin RJ45RS-232160to60°C±48VDC NPort5630-168-pin RJ45RS-422/485160to60°C100-240VAC NPort5650-88-pin RJ45RS-232/422/48580to60°C100-240VAC NPort5650-8-M-SC Multi-mode fiber SC RS-232/422/48580to60°C100-240VAC NPort5650-8-S-SC Single-mode fiber SC RS-232/422/48580to60°C100-240VAC NPort5650-8-T8-pin RJ45RS-232/422/4858-40to75°C100-240VAC NPort5650-8-HV-T8-pin RJ45RS-232/422/4858-40to85°C88-300VDC NPort5650-168-pin RJ45RS-232/422/485160to60°C100-240VAC NPort5650-16-M-SC Multi-mode fiber SC RS-232/422/485160to60°C100-240VAC NPort5650-16-S-SC Single-mode fiber SC RS-232/422/485160to60°C100-240VAC NPort5650-16-T8-pin RJ45RS-232/422/48516-40to75°C100-240VAC NPort5650-16-HV-T8-pin RJ45RS-232/422/48516-40to85°C88-300VDC Accessories(sold separately)CablesCBL-RJ458P-1008-pin RJ45CAT5Ethernet cable,1mCBL-RJ45F25-1508-pin RJ45to DB25female serial cable,1.5mCBL-RJ45F9-1508-pin RJ45to DB9female serial cable,1.5mCBL-RJ45M9-1508-pin RJ45to DB9male serial cable,1.5mCBL-RJ45SF9-1508-pin RJ45to DB25male serial cable with shielding,1.5mCBL-RJ45SF25-1508-pin RJ45to DB25female serial cable with shielding,1.5mCBL-RJ45SM25-1508-pin RJ45to DB9female serial cable with shielding,1.5mCBL-RJ45SM9-1508-pin RJ45to DB9male serial cable with shielding,1.5mConnectorsADP-RJ458P-DB9F DB9female to RJ45connectorADP-RJ458P-DB9M RJ45to DB9male connectorPower CordsPWC-C13AU-3B-183Power cord with Australian(AU)plug,1.83mPWC-C13CN-3B-183Power cord with three-prong China(CN)plug,1.83mPWC-C13EU-3B-183Power cord with Continental Europe(EU)plug,1.83mPWC-C13JP-3B-183Power cord with Japan(JP)plug,7A/125V,1.83mPWC-C13UK-3B-183Power cord with United Kingdom(UK)plug,1.83mPWC-C13US-3B-183Power cord with United States(US)plug,1.83mRack-Mounting KitsWK-45-01Rack-mounting kit,2L-shaped plates,8screws,45x57x2.5mm©Moxa Inc.All rights reserved.Updated Sep04,2019.This document and any portion thereof may not be reproduced or used in any manner whatsoever without the express written permission of Moxa Inc.Product specifications subject to change without notice.Visit our website for the most up-to-date product information.。

华为ma5600设备开局配置

华为ma5600设备开局配置

1华为MA5600设备开局配置华为MA56001.1准备工作第一步:建立本地配置环境,只需将PC(或终端)的串口通过标准RS-232 配置电缆与SCUK板的CON口连接。

第二步:在PC 上运行终端仿真程序(Win9X 的超级终端等),设置终端通信参数为9600bps、8 位数据位、1 位停止位、无校验和无流控,并选择终端类型为VT100。

第三步:路由器上电自检,系统自动进行配置,自检结束后,输入用户名root,密码admin 进入系统。

1.2基本配置enable //进入特权模式config //进入配置视图hostname YC-859-D-MA5600-01 #根据命名规范给设备命名1.3单板配置board confirm 0/0 //单板确认,board confirm 0/1board confirm 0/2board confirm 0/31.4上行口配置interface scu 0/7up 0 //激活端口description TO YCXS-836-S-8508-01 GE1/2 //端口描述quit1.5vlan配置vlan 2 to 449 mux //创建用户VLANYport vlan 2 to 449 0/7 0 //用户VLAN通过的上行口Ymulti-service-port from-vlan 2 board 0-15 vpi 0 vci 100 rx-cttr 1 tx-cttr 1 //将用户端口和VLAN绑定1.6网管配置vlan 3889 standard //创建网管VLANport vlan 3889 0/7 0 //设置上行口允许通过网管VLANinterface vlanif 3889ip address 188.35.3.22 255.255.255.0 //管理地址ip route 0.0.0.0 0.0.0.0 188.35.3.1 //配置默认路由snmp-agent community write wangguansnmp-agent sys-info version allsnmp-agent trap enable standardsnmp-agent trap source vlanif 3889 //管理VLANsnmp-agent target-host trap address 202.102.11.195 securityname wangguan1.7配置速率模板adsl line-profile add 2 //模版配置>Do you want to name the profile (y/n) [n]:y>Please input profile name:1M> Please choose default value type 0-adsl 1-adsl2+ (0~1) [0]:1> Will you set basic configuration for modem? (y/n)[n]:yNote: Setting to these mode of G992.3~5 will lead that the adsl ports that are not supportadsl2+ not be activatedADSL transmission mode:> 0: All (G992.1~5,T413)> 1: Full rate(G992.1/3/5 or T413)> 2: g.lite(G992.2/4) (ADSL over ISDN board doesn't support g.lite mode)> 3: T413(ADSL over ISDN board doesn't support T413 mode)> 4: g.dmt (G992.1/3/5)> 5: g.hs (G992.1~5, G992.5 is prior)> 6: G992.1> 7: G992.2> 8: G992.3> 9: G992.4> 10:G992.5Please select (0~10) [0]:> Trellis mode 0-disable 1-enable (0~1) [1]:> Downstream channel bit swap 0-disable 1-enable (0~1) [1]: 0> Upstream channel bit swap 0-disable 1-enable (0~1) [1]: 0> Please select channel mode 0-interleaved 1-fast (0~1) [0]:> Will you set interleaved delay? (y/n)[n]:y> Maximum downstream interleaved delay(0~255 ms) [16]:> Maximum upstream interleaved delay(0~255 ms) [6]:>Please select form of transmit rate adaptation in downstream:> 0-fixed 1-adaptAtStartup 2-adaptAtRuntime (0~2) [1]:> Will you set SNR margin for modem? (y/n)[n]:y> Target SNR margin in downstream(0~15 dB) [6]:> Minimum SNR margin in downstream (0~6 dB) [0]:> Maximum SNR margin in downstream (6~31 dB) [31]:> Target SNR margin in upstream (0~15 dB) [6]:> Minimum SNR margin in upstream (0~6 dB) [0]:> Maximum SNR margin in upstream (6~31 dB) [31]:> Will you set parameters for rate? (y/n)[n]:y> Minimum transmit rate in downstream (32~32000 Kbps) [32]:> Maximum transmit rate in downstream (32~32000 Kbps) [24544]: 1280 > Minimum transmit rate in upstream (32~3000 Kbps) [32]:> Maximum transmit rate in upstream (32~3000 Kbps) [1024]: 640Add profile 2 successfully1.8用户板配置interface adsl 0/0deactivate allactivate all profile-index 2 //每块用户板都要做interface adsl 0/1deactivate allactivate all profile-index 21.9保存配置save cur //保存配置。

GPON各种设备介绍

GPON各种设备介绍
外观
风扇框具有以下功能:
散热:
风扇框插在机箱的左侧,采用吹风方式实现机箱的通风散热。冷风从机箱左侧进入,经过机箱内各工作单板后,热风由机箱右侧排出。
监控:
风扇框中配置有风扇监控板,可以检测出风扇是否正常工作,并提供接口和主控板通讯,定时将检测信息通过风扇监控板传送到主控板。
调速:
风扇的转速可根据检测出的环境温度自动调节,也可通过手动配置数据来调节。
手动调速:风扇根据主机下发的命令行设置具体的转速等级。可选调速等级有0档~5档,其中0档风速最低,5档风速最高。
1.1.4
介绍MA5680T支持的单板的类别、简称、全称、功能概述。
MA5680T支持的单板如表1-6所示。
表1-1MA5680T支持的单板列表
单板类别
简称
全称
功能概述
主控板
SCUL
超级控制单元板
MA5606T支持的单板如表1-13所示。
表1-1单板列表
单板类别
简称
全称
功能概述
主控板
MCUA
小规模控制单元板
实现对业务板的管理、通过扣板实现业务的上行。支持热插拔。
业务板
EPBA
4路EPON接口板
提供4个EPON接口,与终端ONT(Optical Network Terminal)设备配合完成EPON接入功能。支持热插拔。
工作环境湿度
5%RH~95%RH
气压环境
70kPa~106kPa
海拔高度
2000m以内
电源参数
表1-1电源参数
参数
指标
供电方式
直流供电
工作电压范围
-38.4V~-57.6V
功耗
表1-1整机功耗

MA5600T 产品介绍

MA5600T 产品介绍

全 GPON,单机4K用户接入(FTTH) 业 兼容传统E1线路的Native TDM模式,高 务 质量承载传统E1业务 O GPON/P2P/Native TDM同一平台,满 L 足运营商家庭、商业、移动的全业务运 T
营需要
IGMP
MA5600T
超强组播特性
V3,PIM-SSM
超 高速VDSL2 30a接口支持 强 单/多PVC多业务、 IPoA-IPoE、 PPPoA-PPPoE、802.1X认证等 M VRF、RIP、OSPF、BGP、IS-IS支持 S 基于IP的语音、传真、Modem等基 A 本、补充、智能(800、卡号业务); N
0
PRTG
1
2 x P O N
3 x P O N
4 x P O N
5 x P O N
6
7
8
9 S C U
10 N U L L
11 x P O N
12 x P O N
13 x P O N
14 x P O N
15 x P O N
16 T O P A
17 T O P A
18 19 T O P A
SCUN:600Mpps(主备方式)、1200Mpps (负荷分担方式) SCUL:600Mpps SCUB:72Mpps SCUL:400Gbit/s SCUN:480Gbit/s(主备方式)、960Gbit/s (负荷分担方式) SCUB:48Gbit/s
主控板交换容量
交换转发时延
满负荷误码率
具有较低的转发时延。100Mbit/s以太网端口发 送64Byte以太网数据包,时延不超过20μs。
Page 5
MA5600T产品介绍

SmartAX MA5603T 产品描述(V800R005C03_01)

SmartAX MA5603T 产品描述(V800R005C03_01)

修改记录
修订记录累积了每次文档更新的说明。最新版本的文档包含以前所有文档版本的更新内 容。
文档版本 01 (2009-05-08)
针对 MA5603T V800R005C03,手册初次发行。
vi
华为所有和机密
文档版本 01 (2009-05-08)
版权所有 © 华为技术有限公司
SmartAX MA5603T 多业务接入设备 产品描述
目录
目录
前 言...................................................................................................................................................iii
1 产品定位与特点............................................................................................................................1-1
1.1 产品定位.........................................................................................................................................................1-2 1.2 产品特点.........................................................................................................................................................1-3
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

MA5600机柜系统介绍
本章介绍MA5600机柜的外观、尺寸、重量、配置、外部接线关系、内部接线关系、机柜通风散热原理及防尘网。

本章描述内容如下表所示。

1.1 机柜外观
MA5600配置的机柜为前维护机柜,根据高度的不同分为:
● H66-18
● H66-22
MA5600机柜外观如图1-1所示。

图1-1 MA5600机柜外观图
1.2 尺寸和重量
MA5600机柜的尺寸和重量如表1-1所示。

机柜型号机柜尺寸(宽深高)空机柜重量H66-22 600mm600mm2200mm 95kg
H66-18 600mm600mm1800mm 81kg
1.3 进线孔
MA5600机柜安装线缆时,可以采用上走线或者下走线两种方式,采用上走线时,线缆由机柜顶部进线孔进入,采用下走线时,线缆由机柜底部进线孔进入。

1.3.1 H66-22机柜进线孔
H66-22机柜顶部进线孔如图1-2所示。

图1-1 H66-22机柜顶部进线孔(俯视图)
H66-22机柜底部进线孔如图1-3所示。

图1-2 H66-22机柜底部进线孔(俯视图)
1.3.2 H66-18机柜进线孔
H66-18机柜的顶部进线孔如图1-4所示。

图1-1 H66-18机柜顶部进线孔(俯视图)
H66-18机柜的底部进线孔与H66-22机柜底部进线孔相同如图1-5所示。

图1-2 H66-18机柜底部进线孔(俯视图)
1.4 ESD插孔
MA5600机柜在进行安装操作时,需要佩戴防静电手腕,防静电手腕的接口一端要插在机柜侧门的ESD插孔中,如图1-6所示。

图1-1 ESD插孔位置
1.5 机柜配置
1.5.1 H66-22机柜配置
使用H66-22机柜时,具体配置如图1-7所示。

图1-1 H66-22机柜配置图
使用H66-22机柜时,MA5600的配置参数如表1-2所示。

配置提供最大用户数最大功耗1业务框+1分离器框896 1538W 2业务框+2分离器框1792 3076W 3业务框2688 4515W
1.5.2 H66-18机柜配置
当使用H66-18机柜时,典型配置如图1-8所示。

图1-1 H66-18机柜配置图
使用H66-18机柜时,MA5600典型配置参数如表1-3所示。

1.6 外部接线关系
MA5600的外部线缆支持上走线和下走线。

(以H66-22机柜的配置为例)
当使用交流电源时上走线时的连接关系如图1-9所示,下走线时的连接关系
如图1-10所示。

图1-1 MA5600使用交流供电时上走线的连接关系图图1-2 MA5600使用交流供电时下走线的连接关系图
当使用直流电源内置分离器框配置时,上走线的连接关系如图1-11所示,下
走线的连接关系如图1-12所示。

图1-3 MA5600使用直流供电内置分离器框时上走线的连接关系图图1-4 MA5600使用直流供电内置分离器框时下走线的连接关系图
当使用直流电源外置分离器配置时,上走线的连接关系如图1-13所示,下走
线的连接关系如图1-14所示。

图1-5 MA5600使用直流供电外置分离器框时上走线的连接关系图图1-6 MA5600使用直流供电外置分离器框时下走线的连接关系图
1.7 内部接线关系
1.7.1 H66-22配置
MA5600使用H66-22的机柜时,根据供电类型和分离器是否内置,分为三种
配置:
● 带分离器框的交流配置
● 带分离器框的直流配置
● 不带分离器框的直流配置
具体的配置请参见“1.5 机柜配置”。

带分离器框的交流配置
MA5600使用带分离器框的交流配置时,内部电缆连接如图1-15和图1-16所示。

接线说明如表1-4所示。

图1-1 带分离器框的交流配置内部电缆接线图图1-2 机柜内地线接线图(俯视
带分离器框的直流配置
MA5600使用带分离器框的直流配置时,内部电缆连接如图1-17和图1-18所示,接线说明如表1-5所示。

图1-1 带分离器框的直流配置的内部电缆接线图图1-2 机柜内地线接线图(俯视
不带分离器框的直流配置
MA5600使用不带分离器框的直流配置时,内部电缆连接如图1-19和图1-20所示,接线说明如表1-6所示。

图1-1 不带分离器框的直流配置的内部电缆接线图图1-2 机柜内地线接线图(俯
1.7.2 H66-18配置
MA5600使用H66-18的机柜时,根据供电类型和分离器内置,分为三种配置:
● 带分离器框的交流配置
● 带分离器框的直流配置
● 不带分离器框的直流配置
具体的配置请参见“1.5 机柜配置”。

带分离器框的交流配置
MA5600使用带分离器框的交流配置时,内部电缆连接请参见“1.7.1带分离器框的交流配置”。

带分离器框的直流配置
MA5600使用带分离器框的直流配置时,内部电缆连接如图1-21和图1-22所示,接线说明如表1-7所示。

图1-1 带分离器框的直流配置的内部电缆接线图图1-2 机柜内地线接线图(俯视
不带分离器框的直流配置
MA5600使用不带分离器框的直流配置时,内部电缆连接如图1-23和图1-24所示,接线说明如表1-8所示。

图1-1 不带分离器框的直流配置的内部电缆接线图图1-2 机柜内地线接线图(俯
Modem -48V电源线、Modem信号转接电缆和Modem电话转接电缆由Modem框自带,发货前已经在 Modem框内安装好,在本章中不详细介绍。

1.8 通风散热原理
MA5600业务框上部配置有风扇框,通过抽风方式为机框内的单板散热。

MA5600机柜的通风过程(以配置3个业务框为例说明):
顶部有导风框的机框
配置在机柜最下面的机框和中间的机框顶部有导风框,其通风散热原理如图1-25所示。

步骤 1 冷风从机柜底部及每个机框下方进入机框。

步骤 2 冷风通过风扇的抽风作用,经过业务框带走热量,变为热风。

步骤 3 热风沿导风框的导风板走到机柜后部。

步骤 4 热风从机柜顶部排出。

----结束
图1-1 顶部有导风框的机框通风示意图
顶部没有导风框的机框
配置在机柜最上面的机框顶部没有导风框,其通风散热原理如图1-26所示。

冷风从业务框下方进入机框。

相关文档
最新文档