中央空调设计速成版.
办公楼中央空调设计毕业设计书

办公楼中央空调设计摘要本设计为天津市XX公司办公楼中央空调系统,拟为之设计合理的中央空调系统,为室内工作人员提供舒适的工作环境。
建筑共四层,总面积为4446.9m²,首层净高4.2m,其他三层净高均为3.9m。
要求采用空调夏季制冷冬季供暖。
设计的空调系统采用风机盘管—新风系统,选用水冷机组制冷冻水供冷,冬季依靠市政集中供热采暖。
设计的内容包括:选定合适空调系统的类型并确定设计方案,计算部分也十分重要,例如:空调冷负荷的计算;空调系统的划分与系统方案的确定;冷源的选择;风系统的设计与计算;室内送风方式与气流组织形式的选定;水系统的设计、布置与水力计算;风管系统与水管系统保温层的设计等内容。
除此之外,还需要进行空调末端处理设备及机房辅助设备及的选型。
需要结合所选择的空调系统的特点及办公楼的建筑结构选择合适的空调机组及末端设备,合理的布置吊顶内风管与水管的位置。
并根据所选择的空调机组选配合适的辅助设备:冷冻水循环水泵,冷却水循环水泵,开式水箱,冷却水塔,及相应的水管风管阀门等。
关键词:办公楼,中央空调,水冷机组,风机盘管—新风系统THE CENTRAL AIR-CONDITION OFOFFICIAL BUILDINGABSTRACTThe design of central air-conditioning system for the building of a Tianjin company is aimed to get a comfortable working condition indoors. The total area of the building is 4446.97 m². The height of the first floor is 4.2 meters,and the other three floor’heights are all 3.9 meters. The air-condition system is designed to supply cool air in summer, and a fan coil units (FCUs)--fresh air system is selected and central screw water chillers are used to provide the chilling water needed. In winter, the municipal central heating system is used to supply heat and keep official room warm.Some of the main points in this design are given as follows:To design an appropriate air-conditioning system for the building, the overall analysis is important. This includes the calculation, such as cooling load calculation, the estimation of system zoning; the design of air duct system and calculation; the estimation of air distribution method and the selection of relevant equipments; the design of water system and the analysis of its resistance losses; the plan of the insulation of air duct and chilled water pipes; etc.. Meanwhile, equipment selection is also an essential part of the design. According to the requirement, a fan coil units (FCUs)--fresh air system is appropriate. Thus,the main process equipment, i.e. the chiller, the fan coil units, the circulating water pumps, the cooling tower, are also determined in the design considering their characteristics and working conditions.KEY WORDS:official building, central air conditioning, cooling water chiller fan coil units (FCUs)--fresh air system目录第一章绪论 (1)第二章系统方案的选择确定 (3)第三章工程概况 (5)§ 3.1建筑特点 (5)§ 3.2建筑相关资料 (5)§ 3.3室外设计参数 (6)§ 3.4室内设计参数 (7)第四章空调负荷计算 (8)§ 4.1围护结构瞬变冷负荷计算原理 (8)§ 4.1.1外墙和屋面瞬变传热引起的冷负荷 (8)§ 4.1.2室内传热维护瞬时冷负荷 (8)§ 4.1.3外窗瞬变传热引起的冷负荷 (9)§ 4.1.4设备散热形成的冷负荷 (9)§ 4.1.5新风冷负荷 (11)§ 4.2办公楼围护结构冷负荷计算 (11)§ 4.3各房间送风方式的确定 (14)§ 4.4 办公楼新风量和新风负荷的确定 (15)§ 4.4.1新风负荷计算举例 (15)§ 4.4.2办公楼新风冷负荷计算书 (16)第五章风机盘管加新风系统选型计算 (21)§ 5.1风机盘管系统选型计算 (21)§ 5.2新风机组的选型 (24)第六章空调风系统 (25)§ 6.1空调房间气流组织 (25)§ 6.2风口的布置 (25)§ 6.2.1新风入口注意事项 (25)§ 6.2.2风道的布置和制作要求 (25)§ 6.2.3新、排风口的防雨百叶尺寸的确定 (26)§ 6.2.4风管阀门的选择 (27)§ 6.2.5送风口的布置原则 (27)§ 6.3 风口的选择 (27)§ 6.4 新风管的设计计算 (28)§ 6.6 办公区及卫生间排风 (30)第七章空调水系统 (32)§ 7.1 空调水系统的选型比较 (32)§ 7.2 空调水系统的布置 (33)§ 7.3风机盘管水系统水力计算 (33)§ 7.3.1基本公式 (33)§ 7.3.2标准层的冷冻水供水管路水力计算 (34)§ 7.4 办公楼水管最不利循环水利计算 (37)§ 7.5 空调风机盘管水系统供、回、凝水管 (39)§ 7.6 水管系统中的阀门 (40)第八章机房布置与设备选择 (41)§ 8.1机房布置原则 (41)§ 8.2机房的设备选择 (42)§ 8.2.1冷水机组的选择 (42)§ 8.2.2水泵的选择 (42)§ 8.2.3定压补水水箱选择 (44)§ 8.2.4冷却水塔、水箱的选择计算 (46)第九章管道保温、防腐 (47)结论 (48)参考文献 (49)致谢 (50)附录 (51)第一章绪论本篇文章是对天津某机关办公楼中央空调的设计计算说明。
家用中央空调设计教程42页PPT

家用中央空调设计教程
41、俯仰终宇宙,不乐复何如。 42、夏日长抱饥,寒夜无被眠。 43、不戚戚于贫贱,不汲汲于富贵。 44、欲言无予和,挥杯劝孤影。 45、盛年不重来,一日难再晨。及时 当勉励 ,岁月 不待人 。
ห้องสมุดไป่ตู้ 谢谢你的阅读
❖ 知识就是财富 ❖ 丰富你的人生
71、既然我已经踏上这条道路,那么,任何东西都不应妨碍我沿着这条路走下去。——康德 72、家庭成为快乐的种子在外也不致成为障碍物但在旅行之际却是夜间的伴侣。——西塞罗 73、坚持意志伟大的事业需要始终不渝的精神。——伏尔泰 74、路漫漫其修道远,吾将上下而求索。——屈原 75、内外相应,言行相称。——韩非
中央空调设计速成版

• 送風量V(單位m3/h)= 房間面積 * 房間吊頂高度 * 換 氣次數
中央空調
1
空調房間送風狀態及送風量的確定
4、新風量的確定
2021-11-6
中央空調
1
空調房間送風狀態及送風量的確定
• 因為每人每小時所需的新風量,直接關係到 空調設備的節能,因此應根據實際情況慎重 選擇其數值。
• 各類房間空調負荷分類指標
2021-11-6
中央空調
1
空調負荷的概算指標
• 各類房間空調負荷分類指標
2021-11-6
中央空調
1
空調負荷的概算指標
• 各類房間空調負荷分類指標
2021-11-6
• 說明:1.末端設備冷量參考值=房間面積*單位冷量 2.冰水機組冷量參考值=(0.84~0.86修正值)*末 端總中負央荷空調
中央空調
1
空調水系統設計
• 中央空調水系統,一般包括冷(熱)水系統、 冷卻水系統和冷凝水排放系統。
• 水系統設計,包括管路系統形式選擇、分區 佈置方案、管材、管件選擇、管徑確定、阻 力計算與平衡、水量調節控制、管道保溫、 水泵和冷卻塔等設備的選擇,以及安裝要求 等。
2021-11-6
中央空調
1
2021-11-6
中央空調
1
2021-11-6
空調水系統設計
• 因為變水量系統負荷處於變化狀態,建議在 中央機房內的供回水管之間設置旁通管,並 設置壓差電動調節閥。
• 此外,無論是定水量還是變水量系統,空調 末端設置除設自動控制的電動閥外,為了維 修方便,前後兩邊必須設置截止閥,或增加 旁通裝置。
E、單式水泵系統和複式水泵系統 • 以中央機房的供回水集管為界,冷熱源側和
中央空调设计教程

• 确定型号以后,还需确定风机盘管的安装方式(明装或安装),送回风方式(底送 底回,侧送底回等)以及水管连接位置(左或右)等条件。
对于一般的住宅和办公建筑,房间面积在20m2以下,可选用FP-3.5,25m2 左右的选用FP-5.0,30m2左右的选用FP-6.3,35m2左右的选用FP-7.1。房间面 积较大时应考虑使用多个风机盘管,房间单位面积负荷较大,对噪音要求不 高时可考虑使用风量和制冷量较大的风机盘管。
一般,冷冻水泵和冷却水水泵的台数应和制冷主机一一对应, 并考虑一台备用。补水泵一般按照一用一备的原则选取。
2024/6/9
中央空调
三、冷却塔的选择
1、冷却塔的主要形式
圆形逆流冷却塔
方形横流冷却塔
当然冷却塔的分类形式还有很多种,在这里就不一一列举了。
2024/6/9
中央空调
2、冷却塔的结构
2024/6/9
中央空调
3、冷却塔设计选型
•
1、冷却塔台数与制冷主机的数量一一对应,
可以不考虑备用;
• 2、冷却塔的水流量 = 冷却水系统水量×1.2;
•
• 举例:假设空调系统冷却水量为160m3/h,那 么冷却塔的冷却水量=160 ×1.2=192 m3/h,根 据就近原则,选择冷却塔参数表中冷却水量为 200m3/h 的冷却塔。
2024/6/9
中央空调
水冷螺杆机组水系统流程图(二)
2024/6/9
中央空调
水冷冷水机空调系统
一、制冷主机的选择
• 1.根据建筑的空调面积和房间功能进行空调冷负荷计 算
• 2.统计建筑空调总冷负荷 • 3.大部分建筑需要考虑房间的同时使用率,一般建筑
的同时使用率为70~80%,特殊情况需根据建筑功能和 使用情况确定。 • 4.制冷机冷负荷为建筑空调总冷负荷与同时使用率的 乘积。根据计算的制冷机冷负荷既可选择制冷主机。
中央空调系统设计教程

•
空氣處理機組一般有吊頂式和落地式兩種。落地式包括立式和臥式兩種。
另外機組的送回風方式也有多不同。徐根據建築情況和建築業主要求進行最
終的確定。
•
注意:空調工況的製冷(熱)量比新風工況時要小。
3、組合式空調機組的選擇(略)
七、工程概算
•
1.設備費(除膨脹水箱、軟化水箱、閥門管道和管件以外,全部為設
備費,設備費的準確度應比合同最終簽訂價高8%~10%左右)。
製冷主機台數可根據建築業主和建築所備機房情況進行確定
建築物
辦公室
中部區 周邊 個人辦公室
會議室
學校
教室 圖書館 自助餐廳
公寓
高層,南向 高層,北向
戲院、大會堂
實驗室
圖書館、博物館
醫院
手術室 公共場所
建築物冷負荷估算指標
冷負荷W/m2 顯冷負荷 總冷負荷
逗留者 m2/人
照明 W/m2
65
95
10
60
160
260
逗留者 m2/人
10 4 1.5 2 3 3 2.5 5 2 2 10 10 3.5 15
照明 W/m2
40 50 40 60 40 30 40 30 15 17 15 15 45 30
送風量 l/sm2
10 10 12 10 8 10 10 10 10 12 7 8 9 10
二、水泵的選擇
建築物
衛生所、診所
理髮室、美容院
百貨 商店
地下 中間層
上層
藥店
零售店
精品店
酒吧
餐廳
飯店
房間 公共場所
工廠
裝配室 輕工業
冷負荷W/m2
顯冷負荷
中央空调工程设计方案

中央空调工程设计方案一、项目概述中央空调系统是一种多房间或整个建筑内的空气处理和控制系统。
它用于提供室内空气的舒适性和温度控制,以及为一些特定的生产或加工过程提供特定的温度和湿度条件。
在现代建筑中,中央空调系统已经成为一个不可或缺的部分。
本项目是对某大型商业综合体的中央空调系统进行设计,为了满足不同区域的空调需求和节能要求,需对系统进行全面设计规划。
二、项目目标1.满足商业综合体内不同空间的空调需求,确保室内环境的舒适性和健康性;2.提高中央空调系统的能效比,减少能源消耗和运行成本;3.充分考虑系统的可靠性、安全性和可维护性,减少维护和维修成本;4.根据建筑结构特点,采取合理的系统布局和设计方案,确保系统的稳定性和可持续性。
三、项目规划1.可行性研究:对商业综合体的建筑结构、使用功能和空间布局进行分析,确定中央空调系统的需求和适用方案;2.系统设计:根据商业综合体的空间分布和使用特点,设计中央空调系统的分区控制、温度湿度控制、风量控制等各项参数;3.设备选型:选择适用于商业综合体的中央空调系统设备,包括制冷机组、风机盘管、新风处理机等;4.管道布局:根据建筑结构和系统设计要求,设计中央空调系统的供冷供暖管道布局和连接方式;5.电气设计:制定中央空调系统的电气控制系统,包括设备配电、控制逻辑、安全保护等;6.自动化控制:采用现代化自动化控制技术,对中央空调系统进行智能化控制和运行管理。
四、系统设计1.分区控制:根据商业综合体的空间分布和使用功能,将中央空调系统划分为多个分区进行独立控制,以实现不同区域的空调需求;2.温度湿度控制:根据不同区域的室内气候条件要求,通过风机盘管和温度传感器实现室内温湿度的精确控制;3.风量控制:根据不同区域的空间大小和人员密度,采用不同的风量控制策略,保证不同区域的舒适性和空气质量;4.设备组合:根据商业综合体的总供冷负荷和分区需求,选择合适的制冷机组、风机盘管和新风处理机进行组合配置;5.管道布局:通过对建筑结构和空间布局的深入分析,设计合理的供冷供暖管道布局和连接方式,确保空调系统的运行效率和性能可靠;6.电气控制:对中央空调系统的电气控制系统进行精心设计,采用PLC控制技术和安全保护措施,确保系统的安全稳定运行;7.智能化控制:采用现代化的建筑自动化系统,实现对中央空调系统的远程监控、故障诊断和运行管理,提高系统的可靠性和便捷性。
办公楼中央空调设计(风机盘管加新风系统毕业设计)

办公楼中央空调设计摘要本设计为市XX公司办公楼中央空调系统,拟为之设计合理的中央空调系统,为室工作人员提供舒适的工作环境。
建筑共四层,总面积为4446.9m²,首层净高4.2m,其他三层净高均为3.9m。
要求采用空调夏季制冷冬季供暖。
设计的空调系统采用风机盘管—新风系统,选用水冷机组制冷冻水供冷,冬季依靠市政集中供热采暖。
设计的容包括:选定合适空调系统的类型并确定设计方案,计算部分也十分重要,例如:空调冷负荷的计算;空调系统的划分与系统方案的确定;冷源的选择;风系统的设计与计算;室送风方式与气流组织形式的选定;水系统的设计、布置与水力计算;风管系统与水管系统保温层的设计等容。
除此之外,还需要进行空调末端处理设备及机房辅助设备及的选型。
需要结合所选择的空调系统的特点及办公楼的建筑结构选择合适的空调机组及末端设备,合理的布置吊顶风管与水管的位置。
并根据所选择的空调机组选配合适的辅助设备:冷冻水循环水泵,冷却水循环水泵,开式水箱,冷却水塔,及相应的水管风管阀门等。
关键词:办公楼,中央空调,水冷机组,风机盘管—新风系统THE CENTRAL AIR-CONDITION OFOFFICIAL BUILDINGABSTRACTThe design of central air-conditioning system for the building of a Tianjin company is aimed to get a comfortable working condition indoors. The total area of the building is 4446.97 m². The height of the first floor is 4.2 meters,an d the other three floor’heights are all 3.9 meters. The air-condition system is designed to supply cool air in summer, and a fan coil units (FCUs)--fresh air system is selected and central screw water chillers are used to provide the chilling water needed. In winter, the municipal central heating system is used to supply heat and keep official room warm.Some of the main points in this design are given as follows: To design an appropriate air-conditioning system for the building, the overall analysis is important. This includes the calculation, such as cooling load calculation, the estimation of system zoning; the design of air duct system and calculation; the estimation of air distribution method and the selection of relevant equipments; the design of water system and the analysis of its resistance losses; the plan of the insulation of air duct and chilled water pipes; etc.. Meanwhile, equipment selection is also an essential part of the design. According to the requirement, a fan coil units (FCUs)--fresh air system is appropriate. Thus,the main process equipment, i.e. the chiller, the fan coil units, the circulating water pumps, the cooling tower, are also determined in the design considering their characteristics and working conditions.KEY WORDS:official building, central air conditioning, cooling water chillerfan coil units (FCUs)--fresh air system目录第一章绪论 (1)第二章系统方案的选择确定 (3)第三章工程概况 (5)§ 3.1建筑特点 (5)§ 3.2建筑相关资料 (5)§ 3.3室外设计参数 (6)§ 3.4室设计参数 (7)第四章空调负荷计算 (8)§ 4.1围护结构瞬变冷负荷计算原理 (8)§ 4.1.1外墙和屋面瞬变传热引起的冷负荷 (8)§ 4.1.2室传热维护瞬时冷负荷 (8)§ 4.1.3外窗瞬变传热引起的冷负荷 (9)§ 4.1.4设备散热形成的冷负荷 (9)§ 4.1.5新风冷负荷 (11)§ 4.2办公楼围护结构冷负荷计算 (11)§ 4.3各房间送风方式的确定 (14)§ 4.4 办公楼新风量和新风负荷的确定 (15)§ 4.4.1新风负荷计算举例 (15)§ 4.4.2办公楼新风冷负荷计算书 (16)第五章风机盘管加新风系统选型计算 (21)§ 5.1风机盘管系统选型计算 (21)§ 5.2新风机组的选型 (25)第六章空调风系统 (27)§ 6.1空调房间气流组织 (27)§ 6.2风口的布置 (27)§ 6.2.1新风入口注意事项 (27)§ 6.2.2风道的布置和制作要求 (27)§ 6.2.3新、排风口的防雨百叶尺寸的确定 (28)§ 6.2.4风管阀门的选择 (29)§ 6.2.5送风口的布置原则 (29)§ 6.3 风口的选择 (29)§ 6.4 新风管的设计计算 (30)§ 6.6 办公区及卫生间排风 (32)第七章空调水系统 (34)§ 7.1 空调水系统的选型比较 (34)§ 7.2 空调水系统的布置 (35)§ 7.3风机盘管水系统水力计算 (35)§ 7.3.1基本公式 (35)§ 7.3.2标准层的冷冻水供水管路水力计算 (36)§ 7.4 办公楼水管最不利循环水利计算 (39)§ 7.5 空调风机盘管水系统供、回、凝水管 (41)§ 7.6 水管系统中的阀门 (42)第八章机房布置与设备选择 (43)§ 8.1机房布置原则 (43)§ 8.2机房的设备选择 (44)§ 8.2.1冷水机组的选择 (44)§ 8.2.2水泵的选择 (44)§ 8.2.3定压补水水箱选择 (46)§ 8.2.4冷却水塔、水箱的选择计算 (48)第九章管道保温、防腐 (49)结论 (50)参考文献 (51)致 (52)附录 (53)第一章绪论本篇文章是对某机关办公楼中央空调的设计计算说明。
中央空调设计全过程(新手篇)

中央空调设计全过程(新手篇)设计顺序:先末端,后主机设计原则:合理、经济,最大限度节约运行成本第一章设计方案及适用范围:一、末端部分:1、风机盘管系统;适用范围:一般办公、餐饮等场所2、风机盘管加新风系统;适用范围:要求较高的办公、酒店、餐饮娱乐等场所3、全空气系统;适用范围:商场超市、车间等大开间场所二、主机部分:1、螺杆式冷水机组制冷,市政或锅炉供热;适用范围:有专用机房、电力充足、需专人值守2、风冷机组制冷(制热),市政或锅炉供热;适用范围:空调面积较小、没有机房、无专人值守3、离心式冷水机组制冷,市政或锅炉供热;适用范围:空调面积较大、有专用机房、电力充足、需专人值守4、溴化锂机组制冷(制热),市政或锅炉供热;适用范围:电力不足、有市政热源并经综合比较经济、有专用机房、需专人值守三、其它系统形式:1、一拖多系统;适用范围:空调面积较小、无专用机房、无专人值守、空调面积较大但非同时使用且需独立计费等场所2、风管机系统;适用范围:大开间、无专用机房、无专人值守、控制灵活、初投资较低四、设计程序:1、末端部分:(1)设备选型:1、计算实际空调面积;2、根据使用场所确定冷负荷指标,计算出设计总负荷,根据设备布置特点确定所需设备数量,确定设备型号;冷负荷概算指标:(仅供参考,有高人说现在审图中心已经使用面积负荷法,要求采用逐时负荷计算法)按空调建筑面积估算冷指标(W/m2空调面积)注:本表为最大负荷,在求建筑总冷负荷时,应考虑空调房间同时使用系数0.7-0.9 按建筑面积冷指标进行估算注:l、上述指标为总建筑面积的冷负荷指标:建筑面积的总建筑面积小于5000平米时,取上限;大于l0000平米,取下限值。
2、按上述指标确定的冷负荷,即是制冷机的容量,不必再加系数。
3、由于地区差异较大,上述指标以北京地区为准。
南方地区可按上限采取。
建筑物冷负荷概算指标(香港地区,广东及沿海城市可参考)采用组合式空调器,循环次数商场6~7次,推荐8~9次(2)水系统设计:1、设备定位布置,确定立管位置,根据系统复杂程度确定采用同程式或异程式(当立管和最末端设备距离超过30米时尽量采用同程式);2、确定主管道走向,并和设备合理连接,当主管道有分支时应设阀门以便于调节;3、根据设备流量确定每一管段的水流量,再根据设计水流速计算出管径;4、空调水设计流速为0.9-2.5m/s,管径越大、流速越大,管道比摩阻应小于500;5、水管和设备连接时,进水管上设软接、过滤器、阀门,出水管上设软接、阀门;6、冷凝水管径设计:Q=机组制冷量(KW)7、空调水管保温:(1)当采用超细玻璃棉管壳保温时,供回水管保温厚度采用50mm,冷凝水管保温厚度采用30mm;(2)当采用橡塑材料保温时,供回水管保温厚度采用30mm,冷凝水管保温厚度采用15mm;(3)当冷凝水管采用PVC等塑料管材时,可不作保温处理。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
中央空调 13
空调水系统设计
1、空调冷(热)水系统的设计步骤 (1)选择冷(热)水系统的形式 1)空调水系统的形式 A、双管制和四管制系统 • 对任一空调末端装置,只设一根供水管和一 根回水管,夏季供冷水、冬季供热水,这样 的冷(热)水系统,称为双管制系统; • 对任一空调末端装置,设有两根供水管和两 根回水管,其中一组供回水管用于冷水系统, 另外一组用于热水系统,这样的冷(热)水 系统,称为四管制系统;
2019/4/13
中央空调 15
空调水系统设计
C、异程式和同程式系统 • 风机盘管设在各空调房间内,按照起并联于 供水干管和回水干管间的各机组的循环管路 总长是否相等,可分为异程式和同程式系统。 • 异程式管路系统配置简单,省管材,但各并 联环路管长不等,因而阻力不等,流量分配 难以均衡,增加了初次调整的难度。同程式 各并联环路管长相等,阻力大致相等,流量 分配也较均衡,可减少初次调整的难度,但 初投资较高。
大会堂
体育馆
2019/4/13 中央空调
190~290
280~470
•
说明:1.冰水机组冷量参考值=房间面积*单位冷量
3
空调负荷的概算指标
• 各类房间空调负荷分类指标
2019/4/13
中央空调 4
空调负荷的概算指标
• 各类房间空调负荷分类指标
2019/4/13
中央空调 5
空调负荷的概算指标
• 各类房间空调负荷分类指标
2019/4/13
中央空调 16
空调水系统设计
D、定水量和变水量系统 • 定水量系统中的系统水量是不变的。它通过 改变末端装置的供水量来调节空调房间的负 荷变化。各空调末端装置或各分区水量,采 用手设在空调房内感温器控制的电动三通阀 进行调节。 • 变水量系统则保持空调水系统供、回水的温 度不变,通过改变水系统的水流量来适应空 调负荷的变化,这种系统各空调末端装置的 水流量收设在室内的感温器控制的电动二通 阀进行调节,目前采用变水量调节方式的较 多。
2019/4/13
中央空调 8
空调房间送风状态及送风量的确定
2、送风状态及送风量的确定
• 选定送风温差后,即可按照以下步骤确定送 风状态和送风量: (1)在h-d图上确定室内空气状态点N以及对 应的焓值hN; (2)根据房间的余热Q和余湿D画热湿比过程 线(过N点); (3)根据送风温差,求出送风温度,过它的 等温线与热湿比线的交点即为送风状态 点0; (4)确定送风量 • 计算公式为:G(Kg/h)= -Q/(hN - h0) 送风量V(m3/h) = Q/1.2 中央空调 (1.2m3/kg为空气密度)
中央空调设计速成版
2019/4/13
中央空调 1
目录
• 空调负荷的概算指标 • 空调房间送风状态及送风量的 确定 • 空调水系统设计 • 空调风系统设计 • 中央空调的通风系统
2019/4/13
中央空调 2
空调负荷的概算指标
• 夏季空调冷负荷综合指标
建筑物类型 旅馆、招待所 旅游宾馆 办公大楼 综合大楼 百货大楼 医院 普通电影院 综合影剧院 冷负荷(W/m2) 95~115 140~175 110~140 130~160 140~175 110~140 260~350 290~385
2019/4/13
中央空调 12
空调水系统设计
• 中央空调水系统,一般包括冷(热)水系统、 冷却水系统和冷凝水排放系统。 • 水系统设计,包括管路系统形式选择、分区 布置方案、管材、管件选择、管径确定、阻 力计算与平衡、水量调节控制、管道保温、 水泵和冷却塔等设备的选择,以及安装要求 等。
2019/4/13
•
2019/4/13
说明:1.末端设备冷量参考值=房间面积*单位冷量 2.冰水机组冷量参考值=(0.84~0.86修正值)*末 中央空调 端总负荷
6
空调负荷的概算指标
• 舒适空调室内设计参数
2019/4/13
中央空调 7
空调房间送风状态及送风量的确定
1、送风温差的确定 • 空调系统夏季送风温差,应根据风口类型、 安装高度和气流射程以及是否贴附等因素确 定。 • 舒适性空调, 送风高度H≦5m时,送风温差≦10℃, 送风高度H>5m时,送风温差≦15℃。 • 按风口形式建议的送风温差
9
2019/4/13
空调房间送风状态及送风量的确定
3、洁净室空调送风量的确定
洁净室级别 300,000级 100,000级 10,000级 1,000级 100级 •
2019/4/13
换气次数(n) 10 10~20 20~40 50~80 300~500
送风量V(单位m3/h)= 房间面积 * 房间吊顶高度 * 换 气次数
中央空调 10
空调房间送风状态及送风量的确定
4、新风量的确定
2019/4/13
中央空调 11
空调房间送风状态及送风量的确定
• 因为每人每小时所需的新风量,直接关系到 空调设备的节能,因此应根据实际情况慎重 选择其数值。 • 旅馆客房等设有专用卫生间,新风量应稍大 于排风量,或排风量取为新风量的90%,以维 持室内正压。一般情况下,新风量约为送风 量的10~15% 。 • 新风负荷Q(W)=空气密度(1.2 kg / m3) * 新风量(m3/h)* 室外新风与室内设计回风 状态点的焓差(KJ/kg)
2019/4/13 中央空调 14
空调水系统设计
B、闭式和开式系统 • 闭式系统的水循环管路中无开口处,而开式 系统的末端水管是与大气相通的。开式系统 使用的水泵,除要克服管路阻力损失外,还 需具有把水提升到某一高度的压头,因此, 要求有较大扬程,相应的能耗也较大。闭式 系统管路系统不与大气相通,水泵所需扬程 仅需克服管路阻力损失,不需涉及将水位提 高所需的位置压头,因此,所需扬程较开式 小,相应的能耗也小,并且管路和设备受空 气腐蚀的可能性也小。
2019/4/13 中央空调 17
空调水系统设计
• 因为变水量系统负荷处于变化状态,建议在 中央机房内的供回水管之间设置旁通管,并 设置压差电动调节阀。 • 此外,无论是定水量还是变水量系统,空调 末端设置除设自动控制的电动阀外,为了维 修方便,前后两边必须设置截止阀,或增加 旁通装置。 E、单式水泵系统和复式水泵系统 • 以中央机房的供回水集管为界,冷热源侧和 负荷侧共用水泵的, • 叫单式水泵系统;冷热源侧和负荷侧分别设 置水泵的,叫复式水泵系统,也叫二次泵系 统。