施耐德风机水泵型变频器选型指南

合集下载

施耐德电气低压配电产品选型指南说明书

施耐德电气低压配电产品选型指南说明书

ABB EntrelecSommaireBU0402061SNC 160 003 C0205SummarySelection guide ....................................................................................page 1Screw clamp ........................................................................................page 2Feed through and ground terminal blocks .......................................................page 2 - 5 to 10Single pole, multiclamp terminal blocks..........................................................................page 4Feed through terminal blocks - Double-deck................................................................page 11Feed through terminal blocks - Triple-deck...................................................................page 12Three level sensor, terminal blocks without ground connection...................................page 13Three level sensor, terminal blocks with ground connection ........................................page 14Terminal blocks for distribution boxes, double deck + protection .......................page 15 - 16Interruptible terminal blocks for neutral circuit......................................................page 17 - 18Distribution : phase, ground terminal blocks .......................................................page 19 to 21Single pole or four pole distribution blocks..........................................................page 22 to 24Heavy duty switch terminal blocks with blade......................................................page 25 - 26Heavy duty switch terminal blocks with push-turn knob..............................................page 26Heavy duty switch terminal blocks with contact control pull lever...............................page 29Heavy duty switch terminal blocks with blade - Double-deck .....................................page 27Fuse holder terminal blocks for 5x20 mm (.197x.787 in.) and 5x25 mm (.197x.984 in.)or 6.35x25.4 mm (1/4x1 in.) and 6.35x32 mm (1/4x11/4 in.) fuse s.........................................page 28 - 29Fuse holder terminal blocks for 5x20 mm (.197x.787 in.) and 5x25 mm (.197x.984 in.) fuses -Double-dec k.....................................................................................................................page 27Terminal blocks for test circuits with sliding bridge ......................................................page 30Terminal blocks for metering circuits.............................................................................page 31ESSAILEC terminal blocks.............................................................................................page 32Safety connection terminal blocks ................................................................................page 33Miniblocks for EN 50045 (DIN 46277/2) rail ..........................................................page 34 - 35Spring clamp ......................................................................................page 36Angled terminal blocks - Feed through and ground .....................................................page 36Feed through and ground terminal blocks ...........................................................page 37 to 41Feed through terminal blocks - Double deck ................................................................page 42Terminal blocks for sensors / actuators ........................................................................page 42Terminal blocks for distribution boxes...........................................................................page 43Switch terminal blocks for neutral conductor........................................................page 44 - 45Heavy duty switch terminal blocks with blade..............................................................page 46Fuse holder terminal blocks for 5x20 mm (.197x.787 in.) and 5x25 mm (.197x.984 in.) fuse s....page 47Miniblocks Spring clamp ......................................................................................page 48 to 52ADO - Screw clamp ...........................................................................page 53Feed through and ground terminal blocks ...........................................................page 53 to 56Feed through and ground terminal blocks - Double-deck............................................page 57Heavy duty switch terminal blocks with blade..............................................................page 58Fuse holder terminal blocks for 5x20 mm (.197x.787 in.) and 5x25 mm (.197x.984 in.) fuse s ......page 59 - 60Miniblocks ADO - Screw clamp............................................................................page 61 to 65ADO - ADO .........................................................................................page 66Feed through and ground terminal blocks ...........................................................page 66 to 69Feed through and ground terminal blocks - Double-deck............................................page 70Terminal blocks for sensors / actuators ........................................................................page 71Heavy duty switch terminal blocks with blade..............................................................page 72Fuse holder terminal blocks for 5x20 mm (.197x.787 in.) and 5x25 mm (.197x.984 in.) fuse s ......page 73 - 74Miniblocks ADO - ADO .........................................................................................page 75 to 79Accessories ADO ...........................................................................................................page 80Power terminal blocks .............................................................page 81 to 84Quick-connect terminal blocks .................................................page 85 - 86Terminal blocks for railway applications ................................page 87 to 97Pluggable terminal blocks .....................................................page 98 to 100Accessories......................................................................................page 101Marking..................................................................................page 102 to 104GrossAutomation(877)268-3700··*************************PR30PR3.Z2PR3.G2PR5PR4PR1.Z2Rated wire size :Rated wire size :Rated wire size :Rated wire size :Mounting railsShield terminals forcollector barMarking tableHorizontal Rated wire size :0.5 to 16 mm² (22 to 8 AWG)Rated wire size :Rated wire size :Rated wire size :P a g e t o 29e30 t o 32ag e e3P a ge 8 t o 60a g e6t o 6574P a ge 7 t o 79P a ge 9P a g P a gGrossAutomation(877)268-3700··*************************2ABB Entrelecd010830402051SNC 160 003 C0205MA 2,5/5 - 2.5 mm² blocks - 5 mm .200" spacingAccessoriesGrossAutomation(877)268-3700··*************************3ABB Entrelec D010740402051SNC 160 003 C0205M 4/6 - 4 mm² blocks - 6 mm .238" spacingAccessoriesGrossAutomation(877)268-3700··*************************4ABB EntrelecD011030402051SNC 160 003 C0205M 4/6.3A - 4 mm² blocks - 6 mm .238" spacingM 4/6.4A - 4 mm² blocks - 6 mm .238" spacingGrossAutomation(877)268-3700··*************************5ABB Entrelec D010840402051SNC 160 003 C0205M 6/8 - 6 mm² blocks - 8 mm .315" spacingAccessoriesGrossAutomation(877)268-3700··*************************6ABB EntrelecD010850402051SNC 160 003 C0205M 10/10 - 10 mm² blocks - 10 mm .394" spacingAccessoriesGrossAutomation(877)268-3700··*************************7ABB Entrelec D010860402051SNC 160 003 C0205M 16/12 - 16 mm² blocks - 12 mm .473" spacingAccessoriesGrossAutomation(877)268-3700··*************************8ABB EntrelecD010870402051SNC 160 003 C0205M 35/16 - 35 mm² blocks - 16 mm .630" spacingGrossAutomation(877)268-3700··*************************M 95/26 - 95 mm² blocks - 26 mm 1.02" spacingM 70/22.P - 70 mm² ground block with rail contact - 22 mm .630" spacingSelection35 mm / 1.37"12 mm / 0.47"14-30 Nm / 124-260 Ib.in 1.2-1.4 Nm / 10.6-12.3 Ib.in1000600600415400400577070240 mm 2500 MCM 500 MCM 10 mm 2 6 AWG 6 AWG IEC UL CSANFC DIN0.5 - 160.5 - 100 AWG-600 MCM 2 AWG-500 MCM 50 - 30035 - 24018-6 AWGD 150/31.D10 - 150 mm² blocks - 31 mm 1.22" spacingCharacteristicsD 240/36.D10 - 240 mm² blocks - 36 mm 1.41" spacingSelectionWire size main circuit mm² / AWG VoltageV Current main circuit A Current outputARated wire size main circuit mm² / AWG Rated wire size outputmm² / AWG Wire stripping length main circuit mm / inches Wire stripping length output mm / inches Recommended torque main circuit Nm / Ib.in Recommended torque outputNm / Ib.inSolid Stranded Solid Stranded Wire size output mm² / AWG9.5 mm / .37"0.5-0.8 Nm / 4.4-7.1 Ib.in5003003003220204 mm 212 AWG12 AWG0.2 - 422-12 AWG 22-12 AWG 0.22 - 4IEC ULCSANFC DINCharacteristicsWire size mm² / AWGSolid Stranded D 4/6.T3 - 4 mm² blocks - 6 mm .238" spacingSelectionVoltage V CurrentARated wire sizemm² / AWG Wire stripping length mm / inches Recommended torqueNm / Ib.inM 4/6.T3.P - 4 mm² block - 6 mm .238" spacingD 2,5/6.D - 2.5 mm² blocks - 6 mm .238" spacingD 2,5/6.DL - 2.5 mm² blocks - 6 mm .238" spacingD 2,5/6.DPA1 - 2.5 mm² blocks - 6 mm .238" spacingD 2,5/6.DPAL1 - 2.5 mm² blocks - 6 mm .238" spacingD 4/6... - 4 mm² blocks - 6 mm .238" spacingD 4/6.LNTP - 4 mm² closed blocks - 17.8 mm .700" spacingMA 2,5/5.NT- 2.5 mm² block - 5 mm .200" spacingAccessories**SFB2 : 16 to 35 mm² 6 to 2 AWG H= 3 mm/.12"M 10/10.NT- 10 mm² block - 10 mm .394" spacingAccessories(1) Except for M 35/16 NT (closed block)*SFB1 : 0.5 to 35 mm² 18 to 2 AWG H= 7 mm/.28"**SFB2 : 16 to 35 mm² 6 to 2 AWG H= 3 mm/.12"MB 4/6... - 4 mm² blocks - 6 mm .238" spacingMB 6/8... - 6 mm² blocks - 8 mm .315" spacingMB 10/10... - 10 mm² blocks - 10 mm .394" spacingBRU 125 A - 35 mm² block - 27 mm 1.063" spacingBRU 160 A - 70 mm² block - 35.2 mm 1.388" spacingBRU 250 A - 120 mm² blocks - 44.5 mm 1.752" spacingBRU 400 A - 185 mm² block - 44.5 mm 1.752" spacingAccessoriesAccessoriesBRT 80 A - 16 mm² block - 48 mm 1.89" spacingBRT 125 A - 35 mm² block - 48 mm 1.89" spacingBRT 160 A - 50 mm² block - 50 mm 1.97" spacing9.5 mm / .37"0.5-0.6 Nm / 4.4-5.3 Ib.in4003003002010104 mm 210 AWG 12 AWG 0.5 - 422-10 AWG20-12 AWG0.5 - 2.5IEC ULCSANFC DINMA 2,5/5.SNB - 2.5 mm² blocks - 5 mm .200" spacingCharacteristicsM 4/6.SNB - 4 mm² blocks - 6 mm .238" spacingSelectionWire size mm² / AWGVoltage V CurrentARated wire sizemm² / AWG Wire stripping length mm / inches Recommended torqueNm / Ib.inSolid StrandedM 6/8.SNB - 6 mm² blocks - 8 mm .315" spacing - blade switchingSelectionAccessoriesM 4/8.D2.SF - for fuses 5x20 mm .197x.787 in. and 5x25 mm .197x.984 in. -4 mm² blocks - 8 mm .315" spacingM 4/6.D2.SNBT - 4 mm² blocks - 6 mm .238" spacing - blade switchM 4/8.SF- 4 mm² blocks - 8 mm .315" spacingM 4/8.SFL - 4 mm² blocks - 8 mm .315" spacing12 mm / .472"1.2-1.4 Nm / 10.6-12.3 Ib.in800(1)60060016252510 mm 210 AWG8 AWG0.5 - 1622-10 AWG 22-8 AWG 0.5 - 10IEC ULCSANFC DINCBD2SML 10/13.SF - for fuses 6.35x25.4 mm 1/4x1 in. and 6.35x32 mm 1/4x11/4 in. -10 mm² blocks - 13 mm .512" spacingSelectionAccessoriesCharacteristicsWire size mm² / AWGVoltage V CurrentARated wire sizemm² / AWG Wire stripping length mm / inches Recommended torqueNm / Ib.inSolid Stranded (1) Insulation voltage of terminal block - operating voltage : according to fuse.M 4/6.D2.2S2... - 4 mm² blocks - 6 mm .238" spacing11 mm / .43"0.8-1 Nm / 7.1-8.9 Ib.in50060030306 mm 28 AWG0.5 - 1022-8 AWG0.5 - 6IECULCSANFC DINM 6/8.ST... - 6 mm² blocks - 8 mm .315" spacingCharacteristicsWire size mm² / AWGVoltage V CurrentARated wire sizemm² / AWG Wire stripping length mm / inches Recommended torqueNm / Ib.inSolid Stranded M 6/8.STA - 6 mm² blocks - 8 mm .315" spacing(3)Only for M 6/8.STAM 4/6.ST- 4 mm² blocks - 6 mm .236" spacingBNT...PC...(2) Only for M10/10.ST-SnThe PREM IUM solution for testing the secondary circuits of current or voltage transformers.ESSAILEC, approved by the major electricity utilities, remains the premium choice for the energy market.Implemented in the transformers secondary circuits, ESSAILEC thanks to its intelligent “make before break” design eases and secures any intervention. Cutting the energy supply is avoided with zero risk for the operator.The plug and socket connection cuts cost installation as well as in-situ wiring errors. ESSAILEC is ideal for the wiring of sub-assemblies in the secondary circuits.ESSAILEC terminal blocksProtection relays,Protection relays,Testing :The ESSAILEC socket supplies energy to the protection or counting devices. The insertion of the test plug, which is connected to the measurement equipment, allows the testing of the devices, without perturbing the circuit.ESSAILEC blocks are well adapted to current or voltage measurement :-Current sockets with make before break contacts and pre-wired test plug for current measures-Voltage sockets with open contacts and pre-wired test plug for voltage measures-Up to 4 ammeters or 4 voltmeters connected to the test plugDistributing :The ESSAILEC plug is continuously mounted on the socket to supply current or voltage to secondary circuits sub assemblies.ESSAILEC blocks extreme versatility allow :-Safe current distribution with current socket with mobile contacts since the secondary circuit is not cut when plug is removed-Voltage or polarity distribution with dedicated voltage or polarity socket with closed contactESSAILEC is designed to offer :Great flexibility :-Connection multi contacts « plug and play »-Panel, rail, rack fixed mounting or stand-alone connector -Two wiring technologies, up to 10 mm²Extreme reliability :-Non symmetric blocks -Coding accessories -IP20 design -Locking system -Sealed coverR S T NFor technical characteristics and complete part numbers list, please ask for the ESSAILEC catalog10005006003225254 mm 21.65 mm²12 AWG 13 mm / .51"IECB.SCSANFC DINTS 50-180.5 - 0.8 Nm /4.4 - 7.1 Ib.in0.2 - 422-12 AWG0.22 - 40.5 - 1.50.28 - 1.6580050060041252562.512 AWG 13 mm / .51"0.8 - 1 Nm / 7.1 - 8.9 Ib.inIECB.S CSANFC DINTS 50-180.5 - 1020-12 AWG0.5 - 60.28 - 2.590050060046406510 mm 26 mm² 6 AWG 14 mm / .55"IECB.S UL/CSANFC DINTS 50-181.2 - 1.4 Nm / 10.6 - 12.3 Ib.in0.5 - 1620 - 6 AWG0.5 - 100.28 - 6M 4/6.RS - 4 mm² blocks - 6 mm .238" spacingCharacteristicsWire size mm² / AWGVoltage V CurrentARated wire sizemm² / AWG Wire stripping lengthmm / inches Recommended torque (screw)Nm / Ib.inSolid wire Stranded wire Solid wire Stranded wire Screw clampLugsM 6/8.RS - 6 mm² blocks - 8 mm .315" spacingCharacteristicsWire size mm² / AWGVoltage V CurrentARated wire sizemm² / AWG Wire stripping lengthmm / inches Recommended torque (screw)Nm / Ib.inSolid wire Stranded wire Solid wire Stranded wire Screw clampLugspending M 10/10.RS - 10 mm² blocks - 10 mm .394" spacingCharacteristicsWire size mm² / AWGVoltage V CurrentARated wire sizemm² / AWG Wire stripping lengthmm / inches Recommended torque (screw)Nm / Ib.inSolid wire Stranded wire Solid wire Stranded wire Screw clampLugspending SelectionAccessories(1) Only for block M 4/6.RS (4) For blocks M 4/6.RS and M 6/8.RS(2) Only for block M 6/8.RS(3) Only for block M 10/10.RSDR 1,5/4 - 1.5 mm² blocks - 4 mm .157" spacingDR 1,5/5... - 1.5 mm² blocks - 5 mm .200" spacing。

施耐德变频器选型手册

施耐德变频器选型手册
p
ATS22
软起动器
...........................................................................................4-5
p
ATS48
软起动器
...........................................................................................6-7
ATS 22D88S6U
尺寸
B12.000
30
40751009611073
ATS 22C11S6U
尺寸
C18.000
40
5010012512414082
ATS 22C14S6U
尺寸
C18.000
50
6012515015617091
ATS 22C17S6U
尺寸
150300350361410177
ATS 22C41S6U
尺寸
D33.000
150
–350400414480218
ATS 22C48S6U
尺寸
E50.000

200400500477590251
ATS 22C59S6U
尺寸
E50.000
========================================第10页========================================
(In) (1)
A
出厂设置电流
(IcL)(1)(2)

施耐德软启动变频器选型

施耐德软启动变频器选型

单相 230 V 三相 210...690V
电机功率 变频器
输出频率
0.37...75 kW –
控制类型 异步电机 –
同步电机 –
瞬时过转矩

功能
功能数量
1
预置多段速度的数目

I/O 的数目 模拟输入

逻辑输入
3
模拟输出

逻辑输出
1
继电器输出
1
通讯
集成通讯协议

可选配件

卡 (可选配件)

标准与认证

IEC/EN 60947-4-2 EMC A 类与 B 类 DNV, C-TICK, GOST, CCIB, NOM, UL, CE, CCC, CSA
(1) 供热、通风、空调系统
三相 200...240 V 三相 380...480 V
0.75...75 kW 0.5...200 Hz
kn2 二次比,无传感器磁通矢量控制,电 压/频率比 (2 点),能量节省比 – 瞬时过载:110% 的电机额定电流,持续 60 秒
单相 200...240 V 三相 200...240 V 三相 380...690 V
0.37...2400 kW
0.37...2000 kW
0.5...1600 Hz (最高达 37 kW)
0.1...1600 Hz(最高达 37 kW)
0.5...500 Hz(从 45 至 2400kW)
0.1...500 Hz(从 45 至 2000kW)
kW
HP
(IcL)

0.37-0.55 0.5/– 1.1 0.5-1.5 3 A
0.5 0.75-1.1 1-1.5 2.2-3 2-3

施耐德变频器选型手册

施耐德变频器选型手册
p 对话工具与通讯 ...................................................................................... 41-44
1
选型指导
产品类型
软起动器
通用型变频器
C 应用:
C 应用:
C 应用:
压缩机、泵、风机等 压缩机、泵、风机、 泵、风机等 大惯性机械、传送 装置。
耐德电气从一个优秀的产品和设备供应商逐步成长为整体解决方案提供商。今年,施耐德电气首
次集成其在建筑楼宇、IT、安防、电力及工业过程和设备等五大领域的专业技术和经验,将其高
质量的产品和解决方案融合在一个统一的架构下,通过标准的界面为各行业客户提供一个开放、
透明、节能、高效的 运营成本。
能效管理平台,为企业客户节省高达30%的投资成本和
电机功率 变频器
输出频率
4...400 kW –
控制类型 异步电机 可配置的电压斜坡 控制
同步电机 –
瞬时过转矩

功能
功能数量
预置多段速度的数目
I/O 的数目 模拟输入
逻辑输入
模拟输出
逻辑输出
继电器输出
通讯
集成通讯协议
可选配件
36 – 1 PTC 探头 3 – – 2 Modbus –
卡 (可选配件)
2
复杂、大功率变频器
C 应用:
泵、多泵、风机、压缩机 风机、泵、压缩机,各种标准 转矩应用
C 应用:
传送带、搅拌机、挤出机、 起重等
C 应用:
电力、采矿和选矿、石油和天 然气、水处理等中压系统中的 风机、泵、压缩机等
C 应用:
起重应用、下坡输送带、绞盘、自动扶 梯、高动态驱动器、泵/涡轮组合等

施耐德电气选型手册

施耐德电气选型手册

施耐德低压电器选型接触器:I<=7.5A LC1-D09 22M5C I<=10A LC1-D12 22M5C I<=15.3A LC1-D18 22M5C I<=21A LC1-D25 22M5CI<=27.2A LC1-D32 22M5CI<=34A LC1-D40 22M5C I<=42.2A LC1-D50 22M5C ;I<=55.5A LC1-D65 22M5CI<=68A LC1-D80 22M5CI<=82A LC1-D95 22M5C I<=98A LC1-D115 22M5CI<=128A LC1-D150 22M5C;I<=145A LC1-D170 22M5CI<=175A LC1-D205 22M5CI<=210A LC1-D245 22M5CI<=260A LC1-D300 22M5C I<=350A LC1-D410 22M5C I<=410A LC1-D475 22M5C I<=540A LC1-D620 22M5C热继电器:I<=0.16A LRD-01C I<=0.25A LRD-02C I<=0.40A LRD-03C I<=0.63A LRD-04C I<=1A LRD-05C I<=1.6A LRD-06C I<=2.5A LRD-07C I<=4A LRD-08C I<=6A LRD-10C I<=8A LRD-12C I<=10A LRD-14C I<=13A LRD-16C I<=18A LRD-21C I<=24A LRD-22C I<=32A LRD-32C I<=38A LRD-35C I<=50A LRD-3357C I<=65A LRD-3359C I<=70A LRD-3361C I<=80A LRD-3363C I<=104A LRD-4365 I<=120A LRD-4367 I<=140A LRD-4369空气开关:电机的:I<=11A NSX100HMA 12.5 3PI<=23A NSX100HMA 25 3PI<=45A NSX100HMA 50 3PI<=70A NSX100HMA 80 3PI<=90A NSX100HMA 100 3PI<=140A NSX160HMA 160 3PI<=230A NSX250HMA 250 3PI<=360A NSX400HMIC2.3M 400 3P I<=570A NSX630HMIC2.3M 630 3P 配电的:I<=13A NSX100HTM 16 3P I<=18A NSX100HTM 25 3P I<=29A NSX100HTM 32 3P I<=35A NSX100HTM 40 3P I<=45A NSX100HT M50 3P I<=55A NSX100HTM 63 3P I<=70A NSX100HTM 80 3P I<=90A NSX100HTM 100 3P I<=110A NSX160HTM 125 3P I<=140A NSX160HTM 160 3P I<=180A NSX250HTM 200 3PI<=225A NSX250HTM 250 3P I<=360A NSX400HMIC2.3 400 3PI<=600A NSX630HMIC2.3 630 3P三、中间继电器40、31、22CA2-DN□□M5C常闭接点数量常开接点数量四、框架断路器:I=800A 型号:MT08N13P MIC 5.0AI=1000A 型号:MT10N13P MIC 5.0AI=1250A 型号:MT12N13P MIC 5.0AI=1600A 型号:MT16H13P MIC 5.0AI=2000A 型号:MT20H13P MIC 5.0AI=2500A 型号:MT25H13P MIC 5.0AI=3200A 型号:MT32H13P MIC 5.0AI=4000A 型号:MT40H13P MIC 5.0ATD101B(分体式,P<=45kW)TD101BB(分体式,P>45kW,用三只电流互感器)TD101B-#-M(#用数字1~5代替,1:1A、2:6.3A、3:25A、4:63A、5:100A)(M代表有4~20mA输出,不输出时取消M)TD101BB-#-M(#用数字6~7代替,6:200A、7:400A)(M代表有4~20mA输出,不输出时取消M) 并注明电流互感器的变比。

水泵变频器的选型

水泵变频器的选型

水泵变频器‎的选型选型变频器选型‎时要确定以‎下几点:1、采用变频的‎目的;恒压控制或‎恒流控制等‎。

2、变频器的负‎载类型;如叶片泵或‎容积泵等,特别注意负‎载的性能曲‎线,性能曲线决‎定了应用时‎的方式方法‎。

3、变频器与负‎载的匹配问‎题;1)电压匹配;变频器的额‎定电压与负‎载的额定电‎压相符。

2)电流匹配;普通的离心‎泵,变频器的额‎定电流与电‎机的额定电‎流相符。

对于特殊的‎负载如深水‎泵等则需要‎参考电机性‎能参数,以最大电流‎确定变频器‎电流和过载‎能力。

3)转矩匹配;这种情况在‎恒转矩负载‎或有减速装‎置时有可能‎发生。

4、在使用变频‎器驱动高速‎电机时,由于高速电‎机的电抗小‎,高次谐波增‎加导致输出‎电流值增大‎。

因此用于高‎速电机的变‎频器的选型‎,其容量要稍‎大于普通电‎机的选型。

5、变频器如果‎要长电缆运‎行时,此时要采取‎措施抑制长‎电缆对地耦‎合电容的影‎响,避免变频器‎出力不足,所以在这样‎情况下,变频器容量‎要放大一档‎或者在变频‎器的输出端‎安装输出电‎抗器。

6、对于一些特‎殊的应用场‎合,如高温,高海拔,此时会引起‎变频器的降‎容,变频器容量‎要放大一挡‎。

控制原理图‎设计变频器控制‎原理图设计‎步骤如下:1、首先确认变‎频器的安装‎环境1)工作温度。

变频器内部‎是大功率的‎电子元件,极易受到工‎作温度的影‎响,产品一般要‎求为0~55℃,但为了保证‎工作安全、可靠,使用时应考‎虑留有余地‎,最好控制在‎40℃以下。

在控制箱中‎,变频器一般‎应安装在箱‎体上部,并严格遵守‎产品说明书‎中的安装要‎求,绝对不允许‎把发热元件‎或易发热的‎元件紧靠变‎频器的底部‎安装。

2)环境温度。

温度太高且‎温度变化较‎大时,变频器内部‎易出现结露‎现象,其绝缘性能‎就会大大降‎低,甚至可能引‎发短路事故‎。

必要时,必须在箱中‎增加干燥剂‎和加热器。

在水处理间‎,一般水汽都‎比较重,如果温度变‎化大的话,这个问题会‎比较突出。

施耐德Modicon M340选型书

施耐德Modicon M340选型书

5
外形精巧
仅100mm高,93mm深,包括CPU在内所 有模块均仅有32mm宽
高度:100mm 深度:93mm 灵活的机架:4,6,8及12槽机架,最多可带3个扩展机架 每个模块都具有热插拔功能,不用停机即可方便的进行维护。
稳定可靠
可在恶劣环境中使用
即使环境严酷,也能运转自如
高品质
机械性能 防碰撞 防振动 电气抗干扰 辐射 静电放电 环境条件 温度 海拔
强大的开发功能
Unity Pro软件支持6种语言环境(含中文)。 Unity Pro提供5种IEC编程语言、图形化编程工具、高级在线帮助和大量的数 据输入帮助向导。您可以在程序开发之后立即用模拟器进行测试。在维护阶 段,无需额外编程,高级的诊断工具可以清楚地显示报警,即时诊断及故障 原因自动搜索功能等。
高速连接
Modicon M340处理器上都带有USB口,可以方便高效地与编程PC进行连 接,还可以通过“点对点”模式或者局域网连接到以太网。 即使远程模式下,也能方便安全地访问现场设备,实现在线编程,程序传 输,web服务器远程诊断,FactoryCast Web服务器远程操作,数据文件的 读/写操作……
ᇱ຤ԭ‫ݝ‬
SCADA1
SCADA2
GPRS
Ethernet 100Mbps Modbus TCP/IP
M340 PLC
Modbus CANopen
CANopen
Twido
11
水处理:饮用水处理厂
饮用水处理厂应采用分布式控制系统;每个滤池可单机实现过滤调 节;远程泵站需要与水厂通讯,以实现管网流量和压力的统一调度。
设计说明 b 整个水厂采用环形工业以太网,连接各个主控站Premium PLC。每个滤池 采用独立的M340 PLC实现就地单机控制,各滤池控制站通过以太网与公共冲 洗站通讯。远程泵站采用M340 PLC,并通过GPRS连接到水厂控制系统。

发放施耐德变频器参数设置说明

发放施耐德变频器参数设置说明

发放施耐德变频器参数设置说明施耐德变频器是一种电力变频设备,能够调节电机的转速和输出电压,实现对电力系统的精确控制。

在使用施耐德变频器前,需要对其进行参数设置,以确保其正常运行和满足特定应用需求。

首先,需要设置变频器的基本参数。

这些参数包括电源电压、频率、输出电压、额定电流等。

电源电压和频率是根据应用环境来确定的,需要与电机的额定电压和频率相匹配。

输出电压需要根据具体负载来确定,一般来说,输出电压应该接近于电机工作时的额定电压。

额定电流是电机能够承受的最大电流值,需要根据电机的额定功率和电压来计算。

其次,需要设置变频器的控制方式。

施耐德变频器有多种控制方式可选,例如恒定转速控制、恒定转矩控制等。

恒定转速控制是指通过调节变频器的输出频率来实现电机恒定转速的控制,适合于对转速要求较高的应用。

恒定转矩控制是指通过调节变频器的输出电流来实现电机恒定转矩的控制,适合于对负载变化较大的应用。

需要根据具体应用需求选择合适的控制方式,为此需要了解变频器的各种控制方式的特点和适用范围。

在设置变频器的控制方式时,还需要设置速度和转矩的上下限。

这些限制值可以根据具体应用需求来设定,以保证电机在工作范围内的稳定运行。

比如,可以根据转矩值来确定电机的负载变化范围,从而设定转矩的上下限,避免负载过大或过小导致电机失速或过载。

此外,还需要设置变频器的保护参数。

保护参数包括过流保护、过载保护、过温保护等。

这些保护参数可以根据变频器和电机的额定值来设定,以保证电机在工作过程中不受损坏。

例如,可以设定过流保护值,当电机电流超过这个值时,变频器会自动停机保护。

最后,还需要设置变频器的通信参数。

施耐德变频器支持多种通信协议,例如Modbus、CANopen等。

通过设置通信参数,可以实现与其他设备的数据交换和远程监控。

需要根据具体应用需求选择合适的通信协议和设置相应的参数。

以上是对施耐德变频器参数设置的一些建议,根据具体应用需求和设备技术要求,可能还需要设置其他参数。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
● FM : 电压 0,+10V 或者电流 0-4-20mA 由 SW101切换
● 输入电压 0...10 V : 最小负载阻抗 7.62 k ● 输入电流可以在 0 to 20mA之间设置 : 最大负载阻抗 970 ● 采样时间 : 2 ms ± 0,5 ms ● 分辨率 : 10 bits ● 精度 : ± 1 % (Inputs) 温度变化范围 60 °C ● 线性度 :最大值的± 0,2 %
PC Soft调试软件 – 跟ATV21一样
-串行口或者 蓝牙
SoMove Mobile
为手机定制软件 通过蓝牙适配器 复制存储变频器设置
ATV 212 : M1 – 主要特点
目录
> 市场介绍 > 产品 > 技术参数 > 人机界面 > 问答
产品
电机功率: 0.75 到 75 kW
● 240V 和 400V 3 相
● 紧凑型 , 散热器安装
● 12 种尺寸 IP21 + IP55 两个防护等级 22 … 45kW
0.75 … 2.2kW 3 … 5.5kW
7.5 & 11kW
15 … 18,5kW
55 & 75kW
18.5kW 以下,安装尺寸超小
产品
Altivar 212型号参考
ATV212 . . .. .. . .
● 内置 BMS 常用通讯协议

Apogee FLN / Metasys N2 / BACnet / Modbus 均可菊花链连


Lonworks P1 提供选件
● 蓝牙 连接使无需打开柜子就可进行调试
● 新功能
● 风阀控制 ● 消防功能升级
Altivar 212 新价值
友好
HMI, 简易菜单, 即插即用
可同时使用
产品
通讯
开放 与大多数 BMS主要通讯总线兼容
内置通讯协议 :
• Modbus • BACnet • Apogee FLN P1 • Metasys N2
菊花链连接
通讯选件 :
• Lonworks
产品
新功能
更安全
楼宇中的安全管理
火灾模式
- 强制运行用于排烟
风阀控制
- 风阀未到位,电机不会启动
ATV 212 : M1 – 主要特点
Summary
> 市场介绍 > 产品 > 技术参数 > 人机界面 > Quiz
技术参数
结构 : 功率部分
● EMC 滤波器 :
● Class A (C2) in version N4 IP21 ● Class A or class B (C1) in version N4 IP55
30 : 3 kW – 30 kW
37 :
37 kW
40 : 4 kW
45 :
45 kW
55 : 5.5 kW – 55 kW
选件
X: 无 EMC 滤波器 (仅230V ) C: Class B EMC 滤波器 (仅IP55)
供电电压
M3: 200-240V 三相
N4: 380-480V 三相
● 举例 :
施耐德风机水泵型变频器选 型指南
ATV 212 : M1 – 主要特点
目录
> 市场介绍 > 产品 > 技术参数 > 人机界面 > 问答
ATV 212 : M1 – 主要特点
目录
> 市场介绍 > 产品 > 技术参数 > 人机界面 > 问答
Altivar 212
…. 专为楼宇HVAC设计的变频器
风机水泵的最佳选择
ms)
响应时间 :
FL
10mA for 5VDC
for 24VDC
R
3mA
5A for 250VAC or 30VDC 3A for 250VAC or
30VDC
2A for 250VAC or 30VDC
10ms
7ms ±0.5ms
通讯端口
同时支持两路通讯口
安全
安全功能内置
面向解决方案
内置多种协议,易于集成到楼宇控制系统中。 IP21& IP55 防护, 适合HVAC 应用
简单智能
HMI, 工具, 调试安装简单
ATV212相比于ATV21的提升之处
更灵活, 更易用
Daisy Chain
多功能下载器 Multi Loader
- ATV212需上电 - 使配置更容易 : 1台变频器 5秒钟
紧凑型版本 S 仅 22KW IP21
技术
H: 散热器 IP21
W: IP55
电机功率
0:
< 1kW
U: 个位
1kW ≤ x < 10kW
D: 10位
≥ 10kW
75 : 0.75 kW – 7.5 kW
– 75 kW
11 :
11 kW
15 : 1.5 kW – 15 kW
18 :
18.5 kW
22 : 2.2 kW – 22 kW
市场介绍
● Altivar 212, 是适合楼宇内HVAC设备使用的简单变频器
Buildings
OEM Machine
HVAC
● 它集成了大多数 HVAC专用的功能
* HVAC : 供暖 Heating, 通风 Ventilation, 空调 Air Conditioning
可完全取代ATV21的所有应用, 并有升级
C-Tick
产品
不同版本
IP21 / UL type1
IP55 / Nema12
经验证的 IP21
验证和集成的 IP 21 防护等级,标准配置.
无需机柜,节约成本
验证和集成的 IP 55 防护,等同与电机的防护等级 .
产品
附件
EMC 干扰抑制
附加的 输入EMC 滤波器
允许较长的电缆,并增强抗扰能力 C2 ( class A) → C1 (class B)
1个模拟量输出: FM: 可配置为电压或电流
2个继电器输出: FLA-B-C: 1常开/1常闭 RYA-RYC: 1常开
技术参数
内部电源
● 内部电源带短路及过载保护
● PP : +10.5VDC (±5%) - 10mA
● 模拟输入电压 (电位器 1 to 10 kΩ)
● P24 : +24VDC (±12%) - 200mA
市场介绍
目标应用
● 基本的应用场合如下 :
● 空调 ● 通风 ● 空气处理 ● 制冷 ● ...
● 产品针对全球市场设计
市场介绍
ATV212 :楼宇HVAC变频器
● 遵守所有楼宇相关标准要求 :
● EMC (C2 or C1 filters) 滤波器内置
● 施耐德专有的低谐波技术

不需内置或外加任何直流或交流电抗器, 即可达到THDI < 35%
F : 正转

R : 预设速度 2

RES : 故障复位
● 可编程, 兼容 PLC level 1, norm IEC65A-68
● 输入阻抗 : 4,7 k
● 最高输入电压 : 30 V
● 采样时间 : 2 ms ± 0,5 ms
● 同一端子可以分配多个功能
技术参数
模拟输入
● 2 个模拟输入
● VIA : 电压 0,+10V 电流 0-4-20mA 由 SW100VIA 切换
● VIB : 0,+10V 可由SW100 VIB配置为 PTC 输入*
*用作 PTC 输入 PTC 正常值 <1.5k 短路 值< 50 报警 3k, 复位值 1.8k
● 输入电压 0...10 V : 输入阻抗 30 k ● 输入电流 0 to 20mA
输入阻抗 250 ● 采样时间 maxi
● 正常开关频率 8 或者 12 kHz 降低噪声
● 降低谐波污染
● 无任何选件情况下可实现 THDI<35%
ATV212
EMC filter
M
容易去除EMC滤波器 (ex IT systems)
技术参数
功率端子
ATV212
L1
PA/+
L2
L3 PC/-
U
VM
W
R/L1 S/L2 T/L3
进线
接地 terminal
VIA : 3.5 ms ± 0,5 ms VIB : 22 ms ± 0,5 ms ● 分辨率 : 10 bits ● 精度 : ± 0,6 % (Inputs) 在 60 °C温度变化范围内 ● 线性度 : ± 0,15 % of the maximum value
技术参数
模拟输出
● 1 个模拟输出
• 楼宇HVAC
• 0.18 ~ 75 kW
• 增强火灾控制模式 •风阀控制 • 同 ATV21
•图形终端 • PC Soft • No • Yes • Yes (Power On)
• Yes (Dongle) • Standard • Standard • Standard • Standard • Option card
● 点击完成配置 上电即可工作 ● 调试简单 : 5s即可完成一台调试
● PC 软件调试
● 串行口或者 蓝牙
● SoMove Mobile
● 为手机定制软件 ● 变频器内置蓝牙接口 ● 复制存储变频器设置
产品
通讯
开放 双通讯口配置
通过通讯总线控制变 频器
相关文档
最新文档