手持式细胞计数器
Cellometer细胞计数分析仪

Insert chamber in Cellometer Output data generated instantly
One click to generate more data
18
Vision 结果分析:
Automatically save all results in a data table Fluorescence intensity distribution
PBMC
platelets
PBMC
应用:酵母计数
应用背景: 酵母广泛应用于酿酒、生物燃 料的领域,由于其具有直径 小、出芽(budding)等特性, 常用方法计数比较困难。
常用方法: 手动计数
荧光染料: PI Oxonol
部分客户:
市场:
• Auto T4 • Auto X4(Auto 2000) • Vision
Cell size histograms
Automatically save cell images
Size vs. intensity scatter plot Export all data to Excel
Concentration calculator
可更换滤光片组件:
Cellometer Vision 应用:
Vision提供更加简便,快速的定量
检测细胞表面标志物的方法.
应用:原代肝细胞计数
首次实现原代肝细胞存活率的自动检测
AO & PI Stain
Live
Live
Dead
Live AO
Dead PI
应用:PBMC计数
Using fluorescent stains for accurate concentration and viability: •Fresh PBMCs •Splenocytes •WBCs in whole blood •BAL •Primary hepatocytes
Millipore手持式自动细胞计数器

ScepterHandheld Automated Cell Counter 手持式自动细胞计数器手持式自动细胞计数器Handheld Pipette Form•像移液器一样方便使用•屏幕式使用指导•USB数据下载•72组图形数据的内存传感器前后•2 种类型的传感器•灵敏的电极•精确的进样室•高精度的电子感应检测孔•精确到亚微米的细胞直径•精确到来皮升的细胞体积传感器特点40 µm Sensor60 µm Sensor检测样品浓度范围50,000-1,500,000particles/mL10,000-500,000particles/mL检验颗粒直径范围3-17 um6-36 um建议的检测细胞平均直径4-13 microns8-25 microns目录号50-pack: PHCC40050250-pack: PHCC40250500-pack: PHCC4050050-pack: PHCC60050250-pack: PHCC60250500-pack: PHCC60500Sensor Selection GuideMeasured size (µm)40 µm60 µm NIH 3T315454 beadsAlgae (various)7-9 CHO14-17 Cos-715 Epithelia 14-15 HEK29311-15 HeLa12-14 HepG212 HT-2911 HUH7-Hepatoma lineB Cells6-11 Human ES Cells9-12 HUVEC14-15 Jurkat13K56222 Luminex beads5-6 MCF715-17 MDCK13-15Measuredsize (µm)40 µm60 µm Mouse Embryomic Stem Cell5-13Mesenchymal Stem Cell15-16PBMCs7-12PC129-13Primary Astrocytes7Primary Neuronal CellRat Whole Blood 4.6Rat Dorsal Root Ganglion Cells7Red Blood Cells5-7Rat Neural Stem Cell11-13SF913SH-SY5Y12Splenocytes7-9U26612U87-Human Glioblastoma cell line12-14Yeast-Pichia Pastoris5Yeast-S.cerevisiae6Merck Millipore ValidatedCustomer ValidatedRecommended based on size仪器软件Software Pro•强大的细胞分析平台•直方图叠加比较多组数据和多参数设置表格•构建和保存门的设置Software Pro Analysis PackageAn intuitive, intelligent platform to perform high level cell analysisData:data files from your Scepter device Current Plot:working plot and data file Multifunctional Plot: multiple data sets/ histogram overlaysAnalysis Templates: saved gating parameters Group Stats:customizable stats from your data files selected Export, print selectedgraphs/files, cut and paste订购信息PHCC00000Scepter Handheld Cell Counter-42525 PHCC20040Scepter 2.0 Handheld Cell Counter, with 50pk of 40uM Sensors42525PHCC20060Scepter 2.0 Handheld Cell Counter, with 50pk of 60uM Sensors42525 PHCC60050Scepter Sensors, 60uM, 50PK1186 PHCC60250Scepter Sensors, 60uM, 250 PK (5-50PKs)5747 PHCC60500Scepter Sensors, 60uM, 500PK (10-50PKS)10919 PHCC40050Scepter Sensors, 40um, 50PK2120 PHCC40250Scepter Sensors, 40uM, 250 PK (5-50PKs)10275 PHCC40500Scepter Sensors, 40uM, 500 PK (10-50PKs)19522 PHCC00KIT Scepter 2.0 Startup Kit, 1 Scepter 2.0 pls 12 PKs of Sensors, 60uM51576 PHCC01KIT 2 Scepter 2.0 Handheld Automated Cell Counters80798 PHCC02KIT Scepter 2.0 Start Up Kit, 1 Scepter 2.0 pls 5 packs of 60uM Sensors47307PHCC03KIT Scepter 2.0 Startup Kit, 1 Scepter 2.0 pls 12 PKs of Sensors, 40uM58708PHCC04KIT Scepter 2.0 Start up kit, 1 Scepter 2.0 pls 5 pks of 40uM Sensors51744PHCC05KIT Scepter 2.0 Startup Kit, 1 Scepter 2.0 pls 17 PKs of Sensors, 60uM54737计数器原理-精确记数的保证VoltageV=I RCurrent Resistance•Scepter感应器吸入精确的样本体积•细胞穿过感应器小孔时,电阻值增加。
31例负载自体胃癌细胞裂解物DC-CIK细胞免疫治疗细节体会

31例负载自体胃癌细胞裂解物DC-CIK细胞免疫治疗细节体会发表时间:2013-12-10T14:56:54.357Z 来源:《中外健康文摘》2013年第30期供稿作者:王盛崔玉忠谢秀艳[导读] DC细胞和CIK细胞是肿瘤免疫治疗的两个重要部分。
王盛崔玉忠谢秀艳(滨州医学院附属医院临淄区人民医院 255400)【中图分类号】R967 【文献标识码】A【文章编号】1672-5085(2013)30-0089-03 【摘要】目的总结我院31例(2012年5月到2013年6月)负载自体胃癌细胞裂解物DC-CIK细胞免疫治疗全过程中细节上的心得体会。
方法31例胃癌病人术中保存肿瘤组织,治疗前制备肿瘤抗原,用血细胞分离机采集外周血单个核细胞,体外培养DC-CIK细胞,连续给病人8次回输治疗,同时加强回输时、回输后不良反应的观察及护理。
结果31例病人顺利完成抽血、回输过程,回输后1例病人出现轻微寒战,3例病人在回输后1-3h发热。
结论DC-CIK临床应用安全可靠。
【关键词】自体 DC-CIK细胞体会Details and experience of DC-CIK immunotherapy loaded autologous Gastric Carcinoma cell lysates for 31 cases 【Abstract】Purpose:To summarize details and experience in the whole process of DC-CIK cell immunotherapy loaded autologous gastric carcinoma cell lysates for 31 cases in our hospital from 2012.5 to 2013.6. Methods:The tumor tissues of 31 gastric cancer patients in surgery were saved,and tumor antigen was prepared before treatment, peripheral blood monocytes were collected with blood cell separator, DC-CIK cells were cultured in vitro and then infused for consecutive 8 times for treatment. Meanwhile,the observation and nursing of side effect was carried out during and after treatment. Result:Blood collection and cells injection were smoothly completed in 31 patients ,1 patient showed a slight shiver after cells injection,and 3 patients had a fever 1-3h after treatment. Conclusion:The clinical application of DC-CIK is safe and reliable. 【Key words】autologous DC-CIK cell experience DC细胞和CIK细胞是肿瘤免疫治疗的两个重要部分。
Scepter细胞计数全面介绍

18
Scepter | 28/12/2011
* 来源: Scepter Application Note (Lit. No. AN3775酿酒过程中,精确的酵母计数对于酵母接 种和酵母取样是很重要的,这样,才能保证 整个生产的一致性。
芬兰Sinebrychoff Brewery的发言人在评价 Scepter时说道:
Air bubble in tip Filter is wet Wrong diluent O-ring is damaged or misaligned
Keep tip fully immersed while screen displays Submerge the tip. If Aperture block error appears repeatedly, remove filter cover and dry filter. Refer to maintenance section. Refer to list of acceptable diluents in General Guidelines section. Change or reposition o-ring. Refer to maintenance section. Make sure sample volume is ≥ 100 µL. Keep tip fully immersed while screen displays Submerge the tip.
3 Scepter | 28/12/2011
你认识我么? ?
不同直径的细胞 数量分布 细胞数量
细胞浓度
细胞体积
4 Presentation title in footer | 00 Month 0000
Countstar 细胞计数仪介绍

10µl
30s 活细胞和死细胞浓度, 总细胞浓度,细胞存活 率,细胞的平均大小, 细胞图像
10µl
30s 活细胞和死细胞浓度, 总细胞浓度,细胞存 活率,细胞的平均大 小,细胞图像
通量 染料 CCD分辨率 调焦技术 细胞结团校正 结果输出格式
8 台盼蓝 2592 x 1944(500万像 素) 自动定焦 粗略校正 单一文本格式
样本混匀,加样
插入计数板
自动计数结果
宽广的样品检测范围
• 测量浓度范围:1×104~3×107/ml。 • 直径范围:5-180µm大小的各种原代细胞及传代细胞、干细胞、肿瘤 细胞、血细胞、昆虫细胞、藻类及部分浮游动物。
CHO
MCF7
4T1
Human lymphocyte
MSC
HepG2
微囊藻
隐甲藻
进行相关操作,确保数据的安全性和客观性。
数据输出功能
Countstar细胞计数仪检测结果可以通过JPEG/PDF/EXCEL多格式数
据输出,确保数据的客观真实性,并可以进行后期数据分析和处理。
系统参数
◆ 细胞浓度:1×104-3×107/ml
◆ 细胞直径:5-180μm ◆ 细胞活率范围:0-100% ◆ 样本体积:20μl
Countstar细胞计数仪 与人工计数对比
Countstar细胞计数仪与血球计数板计数细胞活率结果一致,两种方法 计数结果差异无统计学意义(Y=1.0072x;R2=0.9937)
Countstar细胞计数仪 与人工计数对比
Countstar细胞计数仪与血球计数板分别对CHO、MCF-7、HepG2、 MDCK、Vero细胞计数细胞浓度,两种方法计数结果一致,Countstar 细胞计数仪计数结果更准确,重复性测量标准偏差更小。误差线代表 精度
细胞计数仪说明书

1
快速参考卡 (QRC)
1
登录我们的网站/countess,获取完整的使用说明书。 有关 Countess™ 自动细胞计数仪的技术规格及描述信息,请参见第 vii 页。
收到仪器后应立即
仔细检查仪器,是否在运输过程中发生损坏。确定仪器的所有部件 (包括上表列出的附 件) 是否配备齐全。必须与承运商签署损坏索赔条款。保证书不包括运输过程中造成的 损坏。
方法...............................................................................................................................................3
启动........................................................................................................................................................3 一般准则.................................................................................................................................................9 使用 Countess™ 自动细胞计数仪.......................................................................................................10 清洁与维护............................................................................................................................................19 更新和校准 Countess™ 自动细胞计数仪.............................................................................................20 疑难解析................................................................................................................................................22 Countess™ 自动细胞计数仪错误代码...................................................................................................24
手持式放射性检测仪的原理介绍

手持式放射性检测仪的原理介绍随着现代工业的发展和放射性物质的广泛应用,人们对放射性污染的认识和重视程度越来越高。
而手持式放射性检测仪作为一种便携式、灵敏度高、易于使用的检测仪器,得到了广泛的应用。
本文将介绍手持式放射性检测仪的工作原理。
放射性污染的危害放射性污染指的是环境中存在放射性物质而引起的污染。
放射性物质会通过物质之间的相互作用或者核反应释放能量,释放出的粒子或者辐射对人体组织产生破坏性作用,从而导致放射性污染源的辐射危害。
这种辐射破坏人体的组织细胞,对人体的健康造成很大的威胁。
因此,针对放射性污染的危害,开发各种检测仪器来检测放射性物质的浓度和辐射损害程度。
其中最常用的就是手持式放射性检测仪。
手持式放射性检测仪的原理手持式放射性检测仪是一种利用半导体探头检测辐射剂量率的设备,其原理是利用半导体的禁带宽度率随射线所受剂量的变化,通过半导体物理性质的变化检测辐射强度,从而实现对放射性物质的检测。
其主要由探测器、Preamplifier和计数器等组成。
探测器探测器的主要作用是将被检测的辐射引到半导体材料中,使其辐射能量被转化成电荷,进而被测量。
该设备采用了半导体的物理特性,利用半导体探头检测放射物质的辐射剂量率。
探头通常使用硅(Si)或者镉钋(Cd-Pb)半导体材料制成。
半导体材料结构简单、稳定、可靠,检测精度高,但其探头灵敏度较低,因此需要加入Preamplifier进行前置放大。
PreamplifierPreamplifier是对探头信号进行前置放大的装置。
探头收到的信号很小,如果没有前置放大很难被准确检测。
Preamplifier将探头采集的极低信号进行前置放大,使其达到计数器能够处理的信号水平。
同时还对信号进行滤波降噪等处理,提高探测器的信噪比。
前置放大和滤波技术的精度是该设备检测功能的关键。
计数器计数器是在前置放大器之后对信号进行数字化处理,同时计算辐射剂量率的装置。
计数器通常使用微处理器芯片,将处理后的信号传送到CPU进行数字化处理。
细胞计数仪工作原理

细胞计数仪工作原理
细胞计数仪是一种用来计算悬浮在液体中的细胞数量的仪器。
它的工作原理基于光学原理和细胞的特征。
细胞计数仪通过传感器发出一束特定波长的光,这束光经过待测液体中的细胞时,会发生散射和吸收。
在细胞计数仪中,有两个光传感器,一个用来探测前向散射光,另一个用来探测侧向散射光。
对于前向散射光,当光线遇到较大的细胞或颗粒时,会发生散射现象,而小颗粒或溶解物则对光线几乎没有散射作用。
前向散射光的强度与细胞的大小和密度有关,因此可以通过测量前向散射光信号的强度来推断细胞的数量。
对于侧向散射光,当光线遇到细胞或颗粒时,会被散射到侧面,较大的细胞和颗粒会散射更多光线。
侧向散射光的强度与颗粒的大小、形状和内部结构有关,因此可以通过测量侧向散射光信号的强度来推断细胞的形态和结构。
细胞计数仪还会通过光吸收测量细胞的浓度。
当光通过细胞时,会被细胞内的色素或成分吸收,从而减弱光的强度。
通过测量光线在液体中的吸收程度,可以推断细胞的浓度。
通过对前向散射光、侧向散射光和光吸收的测量,细胞计数仪可以计算出液体中的细胞数量和相关的参数。
这些数据可以用于研究细胞的生长状态、细胞学研究和药物筛选等应用。