给水排水毕业设计内容
给排水专业毕业设计论文(全)

摘要本设计是关于贵州省六盘水市给水排水工程的管网设计,它包括给水排水系统、污水排水系统和雨水排水系统。
设计的主要内容和深度应按照基本建设程序及有关的设计规定、规程确定。
通常,给水管道系统的主要设计内容包括:设计基础数据(包括设计地区的面积、设计人口数、用水定额)的确定;给水管道系统的平面布置;给水管道系统设计流量计算和水力计算。
污水系统采用完全分流制排水系统。
污水排水系统的管网设计内容包括划分排水面积,布置管道系统;根据设计人口数和污水定额,计算污水设计流量;根据污水水力计算表进行污水管道的水力计算,确定管径、坡度、流速及埋设深度等设计参数;绘制污水管道平面图和纵剖面图。
雨水排水系统的管网设计内容包括划分排水面积,进行雨水管渠定线,确定出水口的位置;划分设计管段,计算各管段设计流量;根据雨水水力计算表进行雨水管渠水力计算,确定管径、坡度、流速及埋设深度等设计参数;绘制雨水管道平面图和纵剖面图。
关键词:排水系统,管道布置,设计参数,水力计算ABSTRACTThe design is on the LiuPanShui in Guizhou Province, drainage pipe network engineering design includes a water supply and drainage system, a sewage drainage system and a stormwater drainage system.Design of the main contents and depth should be in accordance with the basic constructive procedures and relevant designed rules and procedures. Usually, the main designed content of water supply pipeline system includes: basic designed data (including the area of the design area, designed population and water quota) determination; The layout of Water supply pipeline system; Design flow calculation and hydraulic calculation of Water supply piping system. Sewage system is completely separate and drainage system. The pipe network design content of the sewage drainage system includs the division of the drainage area, layout of piping systems; population and sewage fixed according to the design, calculation of sewage design flow; hydraulic calculation of the sewers, the sewage hydraulic computation to determine the diameter, slope, flow rate and buried depth of the design parameters; draw the sewage pipeline plan and profile maps. Stormwater drainage system pipe network designing content includs division of the drainage area for rainwater sewers, fixing line, determing the outlet location; dividing designed tube segment, calculating each pipe segment design discharge; rain hydraulic Computation conduct rainwater pipe channels cut to divert force calculation, and determine the diameter, slope, and flow rate and burial depth design parameters; draw rainwater pipeline plan and longitudinal section diagram.KEY WORDS:Drainage system, Piping layout, Design parameters, hydraulic calculation目录前言 (1)第1章设计资料 (2)1.1设计任务与内容 (2)1.2贵州省六盘水市某地区状况资料 (2)1.2.3远期规划 (3)1.3 给水管网设计资料 (3)1.3.2绘制日用水量变化曲线及计算水塔、清水池容积的数据资料 (4)1.4 排水管网设计资料 (4)1.4.2雨水的设计 (4)第2章给水管网系统设计 (6)2.1设计水量 (6)2.1.1 最高日用水量计算 (6)2.1.2 消防用水量计算 (7)2.2 绘制日用水量变化曲线及计算水塔和清水池容积 (7)第3章管网布置及水力计算 (11)3.1管网定线 (11)3.2管网水力计算 (12)3.2.1比流量计算 (12)3.2.2由比流量确定管网的沿线流量 (12)3.2.3 节点流量计算 (13)3.2.4初步流量分配 (13)3.2.5管段直径设计 (14)3.3最大用水时管网平差 (14)3.4确定水塔高度、水泵扬程(房屋按4层计算) (16)3.4.1 水塔高度计算 (16)3.4.2 水泵扬程计算 (17)3.5 管网校核 (17)3.5.1不利管段事故时校核(供水能力按70%设计流量校核) (17)3.5.2 消防时管径校核 (21)3.5.3最大转输时校核 (24)第4章排水管网系统 (27)4.1 排水分类 (27)4.2排水系统的体制 (28)4.3排水体制的选择 (29)4.4管道材料及管道系统上的主要构筑物 (31)4.4.1管道材料管道材料有以下要求 (31)4.4.2 管道系统上的主要构筑物 (31)4.5污水管网设计步骤 (32)4.5.1确定排水区界、划分排水流域 (32)4.5.2 污水管道定线 (32)4.6 污水管网流量计算 (33)4.6.1街区编号及面积计算 (33)4.6.2 污水设计流量 (34)4.6.3设计管段的设计流量 (34)4.7污水管道的水力计算 (35)4.7.1 设计参数的选择 (35)第5章雨水管道系统的设计 (48)5.1雨水管渠系统平面布置特点 (48)5.2 雨水管渠设计流量的确定 (49)5.2.1 雨水管渠设计流量计算公式 (49)5.2.2 径流系数的确定 (49)5.2.3设计暴雨强度的确定 (49)5.3 雨水管渠系统的设计步骤 (51)5.3.1 划分排水流域和管道定线 (51)5.3.2 划分设计管段 (51)5.3.3划分并计算各设计管段的汇水面积 (51)5.3.4雨水水力计算 (51)参考文献 (54)致谢信 (56)诚信声明 (57)前言生命离不开水,随着现代社会的飞速发展,人类对水资源的重视程度在不断提高。
给水排水水厂毕业设计

给水排水水厂毕业设计1. 引言在现代城市化发展进程中,给水排水系统的建设和运行成为城市基础设施的重要组成部分。
给水排水水厂作为水资源处理的关键设施,起到了保障城市居民日常用水和处理废水的重要作用。
本文将围绕给水排水水厂的毕业设计展开介绍和分析。
2. 设计目标设计给水排水水厂的主要目标是满足城市居民日常用水和处理废水的需求,确保水质达到卫生标准并实现可持续发展。
具体设计目标包括:1.提供足够的给水量,满足城市的用水需求;2.对废水进行合理处理,确保废水排放符合环境保护要求;3.优化水资源利用,实现节水和循环利用;4.设计合理的给水排水工艺流程,保证系统的安全和可靠性;5.考虑未来的扩展和更新需求,确保水厂的可持续发展。
3. 设计内容设计给水排水水厂的主要内容包括以下几个方面:3.1 给水系统设计给水系统设计主要包括水源选取、水处理工艺和配套设施的设计。
具体步骤如下:1.确定水源选择:根据当地实际情况选择水源,例如地下水、河水、湖水等;2.水质分析和水处理工艺设计:对选定水源进行水质分析,设计合适的水处理工艺,如絮凝、混凝、沉淀、过滤等;3.配套设施设计:设计水厂的建筑布局、设备选择和安装方式等;3.2 排水系统设计排水系统设计主要包括污水收集、处理和排放系统的设计。
具体步骤如下:1.污水收集系统设计:确定污水收集范围和管网布置,考虑排水流量和管网的设计;2.污水处理工艺设计:根据污水的性质和排放标准,设计合适的处理工艺,如生物处理、化学处理等;3.排放系统设计:设计污水排放的方式和管道布置,确保排放水质符合环境保护要求;3.3 自动控制系统设计自动控制系统设计用于对给水排水水厂的运行过程进行监测和控制,提高系统的运行效率和可靠性。
具体步骤如下:1.选择合适的监测仪器和传感器,用于检测水质、流量和压力等参数;2.设计控制系统的硬件和软件,实现对给水排水系统的自动化控制;3.进行系统的集成和调试,确保系统的正常运行和可靠性;4. 设计实施步骤在完成给水排水水厂的设计之前,需要按照以下步骤进行设计实施:1.调研和数据收集:对当地的水资源情况、用水需求和废水排放标准进行调研,收集相关的数据;2.设计方案制定:根据调研结果和设计目标,制定给水排水水厂的设计方案;3.详细设计:根据设计方案,进行详细的给水排水系统设计,包括工艺和设备的选择、管网布置和自动控制系统设计;4.设计评审和修改:对设计进行评审,根据评审结果进行修改和完善;5.设计实施:根据最终确定的设计方案和修改意见,进行设计实施;6.运行调试和验收:在实施完成后,对给水排水系统进行运行调试和验收,确保系统的正常运行;7.毕业设计报告撰写:根据设计实施过程和结果,撰写毕业设计报告。
给水排水毕业设计参考

给水排水毕业设计参考给水排水毕业设计参考近年来,随着城市化进程的不断加快,给水排水系统的建设和改造成为了城市发展的重要课题。
而作为给水排水专业的毕业生,如何进行一项高质量的毕业设计成为了他们面临的重要任务。
本文将从设计思路、技术方案、材料选用等方面,为给水排水毕业设计提供一些参考。
一、设计思路在进行给水排水毕业设计时,首先需要明确设计的目标和需求。
可以从以下几个方面进行思考:1. 城市规划与发展:了解所在城市的规划和发展方向,确定设计的适用范围和需求。
2. 环境保护与可持续发展:考虑设计方案对环境的影响,提出节能减排的措施,促进可持续发展。
3. 技术创新与先进性:关注最新的给水排水技术,探索创新的设计思路,提高设计方案的先进性和可行性。
二、技术方案在设计方案的选择上,可以根据实际情况和需求进行综合考虑。
以下是一些常见的技术方案:1. 给水系统设计:包括水源选择、水质处理、输水管网设计等。
可以考虑利用地下水、河水等作为水源,采用物理、化学和生物等方法进行水质处理,设计合理的输水管网,确保水资源的供应和水质的安全。
2. 排水系统设计:包括雨水排放、污水处理等。
可以考虑采用分流制、蓄滞洪技术等措施,减少雨水对城市的影响;对于污水处理,可以选择生物处理、化学处理等方法,提高污水的处理效果。
3. 智能化设计:结合现代信息技术,将给水排水系统与智能化设备相结合,实现远程监测和控制,提高系统的运行效率和管理水平。
三、材料选用在给水排水系统的建设中,材料的选用至关重要。
以下是一些常用的材料:1. 输水管材料:可以选择铸铁管、钢管、塑料管等。
铸铁管具有耐腐蚀、耐压力大等特点;钢管具有强度高、承压能力强等特点;塑料管具有重量轻、施工方便等特点。
2. 排水管材料:可以选择铸铁管、钢管、塑料管等。
铸铁管具有耐腐蚀、耐压力大等特点;钢管具有强度高、承压能力强等特点;塑料管具有重量轻、施工方便等特点。
3. 水质处理设备:可以选择不锈钢材料,具有耐腐蚀、易清洗等特点。
给排水科学与工程专业《毕业设计》教学大纲

给排水科学与工程专业《毕业设计》教学大纲一、课程背景与目标1.1课程背景《毕业设计》是给排水科学与工程专业的一门重要课程,旨在培养学生在给排水领域的科学研究和工程实践能力,锻炼学生运用所学知识解决实际问题的能力。
1.2课程目标通过《毕业设计》的学习,学生应达到以下目标:1)理解和掌握给排水领域的基本理论和技术;2)具备独立进行科学研究和工程设计的能力;3)掌握数据采集、实验设计和数据分析的方法;4)培养项目管理和撰写科技论文的能力;5)培养团队合作和社会交往能力。
二、教学内容与进度安排2.1教学内容《毕业设计》的教学内容主要包括以下方面的内容:1)研究方向选择和题目确定;2)文献综述与问题研究;3)实验设计与数据采集;4)数据处理与分析;5)结果讨论与成果展示;6)撰写科技论文。
2.2进度安排第1-2周:选题与答辩;第3-5周:文献综述与问题研究;第6-8周:实验设计与数据采集;第9-11周:数据处理与分析;第12-13周:结果讨论与成果展示;第14-16周:撰写科技论文。
三、教学方法与要求3.1教学方法《毕业设计》的教学采用多种方法相结合,包括:1)教师讲授:通过课堂讲解,向学生传授给排水领域的理论与技术知识;2)实验实践:组织学生进行实验设计与数据采集,培养学生动手能力;3)案例分析:通过分析典型案例,引导学生解决实际问题;4)讨论与报告:组织学生进行课题讨论和成果展示,促进学生之间的交流与合作。
3.2教学要求1)学生需认真完成选题与答辩环节,选择与自己专业方向相关的研究题目;2)学生需定期撰写并提交相关的论文、实验报告、进展报告等;3)学生应按时参加课堂讲解、实验实践和讨论报告等教学活动;4)学生应积极参与团队合作,与导师和同学进行良好的沟通与合作。
四、考核方式与评价标准4.1考核方式《毕业设计》的考核主要通过以下几个环节进行:1)论文质量:撰写并提交优秀的科技论文;2)实习报告:撰写并提交规范的实习报告;3)讨论报告:参与并积极发表课题讨论报告;4)结业答辩:完成结业答辩并通过评审。
给排水毕业设计

ABSTRACT
This work was sewage pipe network and sewage treatment plant design for the JH county in the TJ city. According to the requirements of a modern urban sewage treatment, the rainwater and wastewater was discharged in separation system in order to rational utilization of resources in this area.
7.中华人民共和国国家标准,给水排水制图标准(GB/T50106-2001)
8.中华人民共和国国家标准,给水排水设计基本术语标准(GBJ125-89)
9.中华人民共和国国家标准,室外排水设计规范(GB50014,2006)
(二)主要参考书目
1.中国市政工程西南设计研究院主编.给水排水设计手册,第1册,常用资料,北京:中国建筑工业出版社,2000
2.北京市市政工程设计研究院主编.给水排水设计手册,第5册,城镇排水,北京:中国建筑工业出版社,2004
3.上海市政工程设计研究院主编.给水排水设计手册,第9册,专用机械,北京:中国建筑工业出版社,2000
4.中国市政工程西北设计研究院主编.给水排水设计手册,第11册,常用设备,北京:中国建筑工业出版社,2002
河流平均流量5.82 m3/s,平均流速1.07 m/s。
(2)河流最高水位3.80 m(五十年一遇洪水位),
正常水位2.7 m,最低水位1.20 m。
(3)河道宽度4.7 m,河底高程0.20m
给水排水毕业设计

2 工程概况及设计说明2.1 工程概况某地拟建一幢高层综合大楼,总建筑高度77.300m ,地上19层,地下2层。
地下1~2层为车库和设备用房,并且地下2层在战时作为人防地下室;地上1~3层为商场,4层为架空花园,5~19层为高级住宅。
结合该高层建筑的建设,对其给排水系统进行设计。
本工程从市政管网引两路DN150给水管环状布置,一市政接入点在此建筑西南角,埋深1.5m ,另一接入点位于该建筑东北角,埋深1.7m ,常年所提供的供水压力0.35MPa ;最冷月平均水温6℃,总硬度月平均最高值为12.1度。
城市管网不允许直接抽水。
室内粪便污水需经化粪池处理后方可排入城市下水道。
室外排水管道位于主体建筑东南面,埋深2m ,管径200mm ,管材为混凝土管。
室外雨水设计采用成都市暴雨强度公式:0.2310.7682806(10.803lg )(12.3)1,5min,0.6P q t P P t ψ+=+===住宅最高日给水定额为300L/人•d ,时变化系数2.0,设计使用户数根据各层平面图确定;商场员工及顾客给水定额为6L/m2营业厅•d ,时变化系数1.5。
本建筑地下层平时为Ⅱ类汽车库、中危险级Ⅱ级,战时为六级人防二等人员隐蔽所;商场、住宅楼中危险级Ⅰ级。
战时用水量表如下:名称掩蔽面积(m 3)掩蔽人数(P )生活用水量标准 (L/d •P )储水时间(d ) 生活用水量(m 3) 饮用水量标准 (L/d •P )储水时间(d ) 饮用水量(m 3)消毒用水量(m 3) 第一防护单元 1074.78004722.431536 15第二防护单元1034.2750472131533.75152.2 设计依据⒈ 已获批准的设计任务书; ⒉ 设计手册及规范:(1)、建筑给水排水设计规范GB50015—2003(2)、建筑设计防火规范GB50016-2006 (2006年版)(3)、高层民用建筑设计防火规范GB50045—95 (2005年版)(4)、自动喷水灭火系统设计规范GB50084—2001 (2005年版)(5)、人民防空工程设计防火规范GB50098—98(6)核工业部第二研究设计院主编《给水排水设计手册》第2册,中国建筑工业出版社,2003年;(7)陈方肃主编《高层建筑给水排水设计手册》,湖南科学技术出版社,2001年版;2.3 设计内容(1)绘制图纸,图纸总数在20张左右,建议用1#或2#图纸。
建筑给水排水毕业设计

摘要本设计的建筑为十八层的办公综合楼,给排水工程设计包括了建筑给水系统设计,建筑排水系统设计,消火栓系统设计,自动喷淋灭火系统设计。
建筑给水系统分为室内冷水系统和室内热水系统,其中室内冷水系统分为三个区:地下室至四层为低区,采用市政给水管网直接供水;四层至十二层为中区,采用中区变频泵组供水;十三至十八层为高区,采用高区变频泵组供水。
室内热水系统采用局部热水供应系统。
本建筑为一类高层民用建筑,而其建筑高度≥54m,建筑物火灾危险等级为中级危险Ⅰ级。
室内消火栓用水量和室外消火栓用水量分别取20L/s 和40L/s,火灾持续时间为3h,自动喷淋系统计算用水量为22.46L/s,火灾持续时间为1h,消火栓系统和自动喷淋系统前十分钟灭火用水由屋顶水箱提供,屋顶设增压与稳压设备。
排水系统采用污废分流制,污水立管采用双立管排水系统,设专用通气管,废水立管采用单立管排水系统。
给水系统均采用PP-R给水管材,消火栓给水系统和自动喷淋灭火系统采用内外热镀锌钢管,排水系统管材采用UPVC排水管。
在地下层设贮水池和加压泵房,地下室另设集水坑,集水坑中设潜污泵,保证污水及时排出。
关键词:建筑给水排水消防喷淋AbstractThe design of the building for 18 storey office building, to the drainage design of the project include the design of building water supply system, design of building drainage system, the design of fire hydrant system, automatic sprinkler fire extinguishing system design. Building water supply system water system and the life hot water system, which life water system is divided into three zones: basement to four layer for low area, the direct supply of municipal water supply pipe network; four to 12 storeys for the Central District, the central variable frequency pump water; thirteen to eighteen layers for high by high frequency pump water. Local hot water supply system for domestic hot water system. The building is a high-rise building, and the building height is more than 54m, the building fire danger level is extremely dangerous in grade I. Indoor fire hydrant water and outdoor fire hydrant water were taken 20L / s and 40L / s, fire duration 3h, automatic sprinkler system calculating water consumption 22.46L/s, fire duration for 1h, before the fire hydrant system and automatic sprinkler system ten minutes fire fighting water is provided from the roof tank roof design pressurization and pressure stabilizing device. Sewage drainage system uses sewage diversion system, sewage riser using double riser drainage system, dedicated aeration pipe, wastewater riser using single riser drainage system. Water supply system are PP-R water supply pipe, fire hydrant system and automatic sprinkler fire extinguishing system inside and outside the hot galvanized steel pipe, drainage pipe using UPVC drainage tube. In the underground layer design storage tank and pump pressure, underground chamber and the other set puddle, set a puddle in the submersible sewage pump to ensure timely discharge of sewage.Keywords: building Supply water drainage Fire control Spray目录摘要 (iii)Abstract (ii)第1章设计资料 (1)1.1 建筑设计原始资料 (1)第2章建筑给水系统的设计和计算 (2)2.1 室内冷水系统的设计 (2)2.1.1 室内冷水系统方案的确定 (2)2.1.3 冷水管材及管道设备方案安装要求 (5)2.2 室内热水系统的设计 (7)2.2.1 室内热水系统方案的确定 (7)2.2.2热水管材及管道设备安装要求 (9)2.3 室内冷热水系统计算 (11)2.3.1 用水量计算 (11)2.3.2 水池、水表的计算 (12)2.3.3 冷热水管网水力计算 (13)2.3.4 校核与选泵 (24)2.4热水系统计算 (27)2.4.1 热水用水量计算 (27)2.4.2 耗热量计算 (27)2.4.3 热损失计算 (28)2.4.4 热媒耗量计算 (28)2.4.5加热设备的选择和计算 (29)第3章建筑排水系统的设计与计算 (31)3.1 排水系统的设计 (31)3.1.1 排水方案的确定 (31)3.1.2 污废水排水系统类型的确定 (31)3.1.3 系统组成 (32)3.1.4 排水管材与管道布置敷设要求 (33)3.2 排水系统的计算 (38)3.2.1 设计秒流量公式的选用 (38)3.2.2 室内排水管道水力计算 (39)3.2.3 通气管管径的确定 (50)第4章消火栓系统的设计与计算 (51)4.1消火栓系统的设计 (51)4.1.1 室外消火栓系统布置要求 (51)4.1.2 室内消火栓系统布置要求 (52)4.1.3室内消火栓系统布置 (56)4.2消火栓系统的计算 (57)4.2.1 消火栓系统用水量 (57)4.2.2 消火栓系统的水力计算 (57)4.2.3 消防水箱 (61)第5章自动喷水灭火系统的设计与计算 (63)5.1自动喷水灭火系统的设计 (63)5.1.1 自动喷水灭火系统的布置要求 (63)5.1.2 自动喷水灭火系统类型的确定 (63)5.1.3 系统的组成 (64)5.1.4系统自动喷水灭火系统技术参数的组成 (64)5.1.5自动喷水灭火系统设计 (65)5.1.6 喷头选择 (65)5.2自动喷水灭火系统计算 (66)5.2.1 设计计算基本参数 (66)5.2.2 自动喷水灭火系统的水力计算 (66)参考文献 (71)致谢 (72)第1章设计资料1.1建筑设计原始资料图纸资料:建筑所在地总平面图,建筑底层平面图、首层平面图、二层平面图、标准层平面图、顶层平面图等。
全国给排水科学与工程本科生优秀毕业设计

全国给排水科学与工程本科生优秀毕业设计随着城市化进程的加速,给排水科学与工程领域的重要性日益凸显。
作为这一领域的学生,优秀的毕业设计不仅是对自身学业的总结,更是对专业知识的应用和实践,也是对社会发展的贡献。
全国各高校对给排水科学与工程本科生的毕业设计都寄予了厚望,希望他们围绕行业热点和实际需求,做出有价值的成果。
本文将对全国给排水科学与工程本科生优秀毕业设计进行总结和分析,以期为各相关专业提供有益的借鉴和参考。
一、设计主题选择1.1 环保节能优秀的毕业设计主题应当与时俱进,紧跟环保节能的潮流。
设计一种新型的污水处理工艺,提高污水处理的效率和降低能耗;或者设计一种新型的雨水利用系统,实现雨水资源的合理利用,减少城市排水压力。
1.2 城市化治理随着城市化进程的不断加速,城市给排水系统的建设和管理面临着越来越大的挑战。
可以选择设计一种智能化的城市给排水管理系统,提高系统的稳定性和智能化程度,为城市给排水系统的健康发展做出贡献。
1.3 新材料应用新材料的研发和应用一直是给排水科学与工程领域的热点之一。
学生可以选择在毕业设计中探索新颖的材料应用,如新型过滤材料、抗腐蚀材料等,为行业的技术创新贡献自己的力量。
二、设计内容及方法2.1 理论分析在毕业设计中,学生应当充分运用所学的专业知识,对设计主题进行深入的理论分析,明确所选择主题的核心问题,并找出合理的解决方案。
2.2 数据收集毕业设计需要建立在大量的实际数据基础之上,学生应该积极开展调研和实验工作,收集相关领域的数据和信息。
在数据分析的基础上,对设计方案和解决途径进行合理的优化和调整。
2.3 技术实践优秀的毕业设计要求学生能够将理论知识与实际技术相结合,在实践中检验和验证设计方案的可行性。
学生可以利用实验室或外部实习机会,进行相关技术的验证和改进工作。
三、设计成果及意义3.1 设计成果毕业设计的成果可以体现在论文、实际操作系统、模型或者其他创新产品上。
学生需要清晰地呈现出自己的设计思路、技术方案、成果和创新点,以及其对给排水科学与工程领域的积极影响。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
武汉科技大学城市学院毕业设计设计题目: 宜居新城一期建筑给排水工程设计研究学部:城建专业:10级给水排水学号:201010130120姓名:吴..指导老师:...目录摘要…………………………………………………………ABSTRC………………………………………………………第一卷第一册设计说明…………………………………第二卷第二册工程概算书………………………………第三卷第三册图纸目录…………………………………参考文献……………………………………………………致谢…………………………………………………………附录1 外文参考文献(译文)……………………………附录2 外文参考文献(原文)……………………………宜居新城一期建筑给排水工程设计研究摘要本设计的建筑为一十三层的商住楼,给排水工程设计包括了室内生活给水系统设计,室内排水系统设计,室内消防给水系统设计,以及雨水系统设计。
生活给水系统分为两个区:地下室至三层为低区,采用市政给水管网直接供水;四层至二十三层为高区,利用屋顶高位水箱给系统供水。
消防给水系统分为消火栓给水系统和自动喷淋灭火系统,本建筑为一类民用建筑,而其建筑高度≥50m,按《高层民用建筑防火设计规范》规定,室内消火栓用水量和室外消火栓用水量分别取20L/s和15L/s,自动喷淋系统计算用水量为16L/s,自动喷淋系统在屋顶设增压设备。
排水系统采用污废合流制,排水系统采用特殊的伸顶通气单立管排水系统,通气冒高出屋顶1.00m。
给水系统采用PP-R 给水管材,消火栓给水系统和自动喷淋灭火系统采用无缝镀锌钢管,排水系统立管采用PPI螺旋排水管,各层排水支管采用普通的UPVC排水管。
在地下层设贮水池和加压泵房,地下室另设集水坑,集水坑中设潜污泵,保证污水及时排出。
关键词:建筑给水消防排水AbstractWork in the complex building for23 floors of trade in the building originally designed, is it drain off water engineering design including room is it supply water system design , indoor fire control supply water the system is designed and the indoor drainage system set up to live to give. Life supplies water and is divided into two districts systematically: The ground lower floor to 3floor are the low district, adopt the pipe network of municipal water supply and supply water directly; 4are the high district to the 23th Floor, supply water for the system with the high-order water tank of the roof. Fire control supply water system divide into fire hydrant supply water system and automatic spray fire extinguishing system, building this one building, but area its does not exceed 1000m2, stipulate according to " high-story civil building fire prevention the design specification ", water consumption of the indoor fire hydrant and outdoor fire hydrant water consumption fetch 20L/s and15L/s respectively, automatic spray systematic water consumption fetch 16L/s, automatic spray system set up the pressurized equipment on the roof. Supply water system adopt PP-R supply water pipe , fire hydrant supply water system and automatic spray fire extinguishing system adopted and has not sewn the zinc-plated steel tube , the drainage system sets up and is in charge of adopting PPI spiral drain pipe, drain off water and prop up in charge of adopting ordinary UPVC drain piping on the everyth floor. Sets up the storage cistern and pressurizes in the pump house in the ground lower floor, the basement sets up and collects the puddle separately , collect and set up and sneak the corrupt pump in the puddle, guarantee sewages are discharged in time.Key word: Building Supply water Fire control Spray宜居新城一期建筑给排水工程设计研究第一卷第一册设计说明书武汉科技大学城市学院二零一四年五月目录第一卷第一册设计说明1.工程概述1.1设计任务1.2 设计参考依据及设计资料1.3 设计成果2.设计说明2.1 室内给水系统2.1.1水源及给水工艺的选择2.1.2给水系统组成2.1.3设计参数及生活用水量2.1.4管道布置及设备安装要求2.2 室内消火栓给水系统2.2.1系统的选择2.2.2系统的组成2.2.3消防管道及设备安装要求2.3 室内排水系统2.3.1 排水系统的选择2.3.2 排水系统的组成2.3.3 排水管道的安装要求1工程概况1.1设计任务按照上级批准的设计任务书规定,完成某13层(地下一层)商住楼建筑给排水工程设计。
要求设计室内给排水工程与土建工程配套,具体项目为:1、建筑给水工程2、建筑排水工程3、建筑消防给水工程1.2 设计参考依据及设计资料1、《建筑给排水设计规范》(GB50015-2003)2、《建筑设计防火规范》(GBJ16-87)3、《高层民用建筑设计防火规范》(GB50045-95)4、《自动喷水灭火系统设计规范》(GB50084-2001)5、《水喷雾灭火系统设计规范》(GB50219-95)6、建筑提供的各层平面图等条件图7、基本资料拟建一栋13层的商住楼,建筑高度46.4米。
地下一层,地上13层,一、二层为商业用,均设有公共卫生间。
3至13层为公寓,每户均按3.0人计。
该建筑物北侧道路下有市政给水管道,管径为DN400,常年可提供的资用水头为0.30MP,允许接管径为DN200,大楼40米范围无室外消火栓,污水管管径为DN600,管顶埋深为2.4米,雨水管管径为DN1200,管顶埋深为1.6米。
8、气象资料该市气候温和,地质条件较好。
最大积雪深度为200mm。
1.3 设计成果1、毕业设计说明书、计算书毕业设计说明书、计算书主要包括以下内容:工程概况(包括设计依据、设计资料、设计规模等),给水方案的选择,各系统的设计计算(包括建筑内部给水系统、排水系统、消火栓给水系统的设计计算,有增压、贮水设备的要进行增压、贮水设备的计算及选型等),其它内容(包括目录、中英文摘要、参考文献、小结等)。
2、设计图纸毕业设计图纸包括各层给水系统、排水系统、消火栓系统平面布置图,给水系统、排水系统、消火栓系统各系统图,卫生间大样图。
要求图面布局合理,正确清晰,用工程字注文,符合制图标准及有关规定。
2设计说明该建筑共13层,地下一层及一层为4.75米,二层为3.9米,三层至十三层为2.8米,建筑高度为46.4米。
2.1 室内给水系统2.1.1水源及给水工艺的选择由《给排水设计手册》可知:内部给水系统应尽量利用外部给水管网的水压直接供水。
在外部管网水压不能满足整个建筑或建筑小区的用水要求时,则建筑物的下层或地势较低的建筑,应尽量利用外管网的水压直接供水,上层或地势较高的建筑设置加压和流量调节装置供水。
由设计资料可知:市政管网可供水压为0.3MP,此水压远不能满足用水要求,故需二次加压,所以必须分区供水。
考虑到本建筑地下一层主要为停车区,一二层为商用区,三层及以上为公寓,故选择地下一层及一二层为低区,三层及以上为高区。
同时,由于该楼体中部存在楼面平接及墙体交接变形缝,故横向分区供水,分为左区和右区。
生活区的给水可以用到二种方式:①由增压水泵直接加压供给的下行上给式;②由高水箱供给的上行下给式。
方案一:低区-1-2层利用市政管网水压供水,高区3-13层利用变频泵从生活水池吸水供水。
方案二:低区-1-2层利用市政管网水压供水,高区3-13层利用高位水箱供水,在中间设置减压阀进行减压。
方案一的优点是供水可以随时间变化,水泵的流量由变频控制,自动改变水泵的转速,使水泵经常处于高效状态,能量损耗小。
缺点是需要一套较贵的变速水泵及其自动控制设备,且维修较复杂。
方案二的优点是减压阀不占楼层的房间的面积,使建筑物的面积发挥最大的经济效益,其缺点是减压阀宜损坏,有较大的能量损耗。
经方案比较,该建筑有足够的空间设置减压阀,本设计应该采用第二方案。
2.1.2给水系统组成本建筑的给水系统是:低区为-1至2层,采用下行上给供水方式,即城市管网直接供低区各卫生器具。
高区为3至13层,共11层,采用上行下给供水方式,用高位水箱供水,中间设置减压阀。
即城市管网→地下贮水池→水泵→屋顶水箱→高区各卫生器具。
低区由引入管、水表节点、给水管网和附件组成,高区由引入管、水表节点、地下贮水池、水泵、屋顶水箱、给水管网及附件组成。