475 说明书
475 Field Communicator产品数据手册说明书

475FieldCommunicatorProduct Data SheetJuly 2010I Full-color graphical user interfaceI Powerful field diagnostics I Bluetooth ®communication I Long-lasting Lithium-Ion power moduleIUniversal support for HART ®and F OUNDATION ™fieldbus devices475Field CommunicatorWhat you get is the most powerful handheld available –universal,user upgradeable,intrinsically safe,rugged and reliable.Only the 475Field Communicator can deliver all this in a single handheld communicator.IntroductionThe 475Field Communicator builds on the industry-leading technology of the 375Field Communicator while adding innovative newcapabilities including color display,Bluetooth communication,and advanced field diagnostics with applications like ValveLink ™Mobile.The 475Field Communicator is designed to support all HART and F OUNDATION fieldbus devices from all vendors.1981Product Data Sheet July2010Product DescriptionThe475Field Communicator is designed to simplify your work in the field.The intuitive full color user interface allows you to leverage the same practices for both HART and F OUNDATION fieldbus devices.It includes a larger touch screen than PDAsor Pocket PCs,supports HART versions5,6,and7(including Wireless HART™)devices,and allows you to upgrade your475 Field Communicator onsite using the Internet.See and Feel the Difference The touch screen display uses transflective technology,making it easy to read in both bright sunlight and normal lighting.To make sureall conditions are covered,amulti-level backlight is included,allowing bright,crisp display evenin plant areas with dim light.The touch screen display and largephysical navigation buttons providefor efficient use both on the benchand in the field.The full color graphics capability isprovided as standard with every475Field Communicator.It usespowerful EDDL technology to allowyou to read data from field devicesin a graphical manner.Charts,graphs,gauges,and productimages are just a few of the waysin which important device data canbe displayed using the475FieldCommunicator’s color LCD display.The weight of the475FieldCommunicator is evenlydistributed for comfortableone-handed operation in the field.It runs on Windows CE,a robust,real-time operating system.The475Field Communicatorhas plenty of memory to allow forfuture expansion.It has32MB ofapplication memory and1GB ofmemory on its System Card.User UpgradeableEasy Upgrade Keeps YourCommunicator CurrentThe475Field Communicator isuser upgradeable via the Internet.Avoid the time delays of sendingyour communicator to a servicecenter for upgrades.With theEasy Upgrade option,you candownload new device drivers,functionality,or licenses directlyto your475Field Communicator.Keeping your475FieldCommunicator updated is easy.New HART and F OUNDATIONfieldbus devices,as well asfunctional updates to existingdevices,are introduced continuallyby device vendors.Keepingup-to-date with the requiredDevice Descriptions(DDs)for allthe devices in your plant can bea real challenge.With Easy Upgrade,when newHART and F OUNDATION fieldbusDDs become available,you cansimply download them from theInternet and upgrade your475Field Communicator.Update atyour site,within your control,when it’s convenient for you.Gain advanced diagnostics in the field through ValveLink Mobile and enhanced graphics.Page2Through Easy Upgrade ,you always have access to the latest HART and fieldbus drivers.With the 475Field Communicator,you are guaranteed universal HART and F OUNDATION fieldbus support in a single,intrinsically safe handheld communicator.Page 3Online LicensingThe Online Licensing capability provided with Easy Upgradeallows you to enable new options for your 475Field Communicator over the Internet.With Online Licensing,powerful options like F OUNDATION fieldbus can be added by simply purchasing the license and downloading it directly to your communicator.Universal –HART and F OUNDATION fieldbusWith over 1,100different HART and F OUNDATION fieldbus devices available from more than 100manufacturers,the 475Field Communicator works with all your devices to positively impact your bottom line.475FieldCommunicatorThe Easy Upgrade Utility allows you to transfer system software,DDs,and HART device configurations between the 475Field Communicator and a PC.Connect using IrDA,Bluetooth,or an SD Card Reader.((()))Easily store and print device configurations for analysis and documentation requirements.Rugged and ReliableIt’s called “Field Communicator”for a reason.Some tasks just have to be performed at thedevice in the field.The 475Field Communicator is designed for tough use in your plant or mill.Its large keys and physical navigation buttons allow forone-handed operation,even with your work gloves on.The rugged display is designed to take the knocks and shocks from normal use in the plant.The 475Field Communicator’s Protective Rubber Boot provides added protection in the field and in your toolbox.Both the rubber boot and 475housing are designed in accordance with Intrinsic Safety standards to limitIntrinsically SafeThe 475Field Communicator meets the Intrinsic Safety requirements of the listed regulatory agencies andstandards.All of the available Hazardous Locations approvals are provided in a single model option (see Ordering Information).–CENELEC/ATEX –Factory Mutual (FM)–Canadian Standards Association (CSA)–FISCO –IECExPage 4the build up of static electrical energy.The 475Field Communicator is designed,manufactured,and tested to very demandingspecifications.It is ready to go wherever you need to go to get the jobdone.ATEXThe 475Field Communicator,with its handy carrying case,provides a single tool for configuring and diagnosing HART and F OUNDATION fieldbus devices.Even the power module is approved for installation in hazardousareas.The protective rubber boot provides added protection in the field.Product Data SheetJuly 2010Page 5475FieldCommunicatorPowerful DiagnosticsInterface with AMS Device ManagerThe 475Field Communicator is fully compatible with AMS Device Manager,the industry standard for asset management software.In fact,Control Magazine readers have selected AMS Device Manager as the #1Calibration Software package for over 10years in a row.AMS Device Manager uses the intelligence from field devices to create a predictive maintenance environment.AMS Device Manager allows you to configure,calibrate,configurations in yourcommunicator or transfer them to AMS Device Manager.Together,the 475FieldCommunicator and AMS Device Manager enable you to efficiently manage all of your devices.Device Configuration ManagementUsing the Easy Upgrade Utility,you can back up hundreds of device configurations and can transfer them between your communicator and a PC.This library of device configurations is easy to view and print for analysis.document,and troubleshoot HART ,F OUNDATION fieldbus,and WirelessHART devices.Transfer device configuration data to AMS Device Manager via the IrDA port or Bluetooth interface on your 475Field Communicator and PC.Take your 475Field Communicator out to the field to configure or update one or more devices.Save up to 1,000devicePage 6Detect power supply problems by monitoring low frequency noise on a segment.Locate incorrect terminations and faulty devices by diagnosing the communications signal level.For HART loops,the 475Field Communicator allows you to verify whether the DC voltage in the loop is correct.an asset management system like AMS Suite for in-depth analysis and documentation.Diagnose Network Problems The 475Field Communicator can be used to configure all the F OUNDATION fieldbus devices in your e it to perform diagnostics for effective start-up and troubleshooting of fieldbus segments.Create a quality segment by diagnosing the network DC voltage and average noise.Identify Valve Problems Run valve diagnostics in the field with the ValveLink Mobile application.You can quickly perform tests including valve signature,dynamic error band,and step response on HART Fisher ®FIELDVUE ™digital valve controllers.ValveLink Mobile does not currently support F OUNDATION fieldbus devices.The intuitive user interface makes ValveLink Mobile easy to use and understand.Diagnose issues in the field or transfer the results toSpecificationsMicroprocessorI 80MHz Hitachi ®SH3Memory Internal Flash I 32MBSystem CardI 1GB secure digital card RAMI 32MB WeightI Approximately 1.65lb.(0.75kg)with battery DisplayI 1/4VGA (240by 320pixels)color,3.5in.(8.9cm)transflective display with touch screen I Anti-glare coatedKeypadI25keys including 4action keys,12alphanumeric keys,tab key,function key,backlight key,power key,and 4cursor-control (arrow)keys;membrane design with tactile feedbackUsageI -10°C (14°F )to +50°C (122°F )I 0%to 95%RH (non-condensing)for 0°C (32°F )to +50°C (122°F )ChargeI 10°C (50°F )to +40°C (104°F )Storage With BatteriesI -20°C (-4°F )to +55°C (131°F )Storage Without BatteriesI -20°C (-4°F )to +60°C (140°F )Enclosure Rating IIP51(from front)ShockI Tested to survive a 1-meter drop test onto concrete UsageIPC with Internet access I CD Rom driveI IrDA port (or adapter)or Bluetooth (or adapter)I SD Card Reader (required for some upgrades)I Windows XP (SP2or SP3)or Windows Vista Business (SP1)BatteryI Rechargeable Lithium-Ion power module Battery Operating TimeI 20hours –continuous use I 40hours –typical use I 80hours –standby modeBattery Charger OptionsI Input voltage 100-240VAC,50-60Hz I Cables included with U.S.,Europe,and U.K.plugs Battery ChargerIMini DIN 6-pin jackHART and FieldbusI Three 4mm banana plugs (one common to HART and F OUNDATION fieldbus)IrDA PortI IrDA (Infrared Data Access)port supporting up to 115KbpsI ±15degrees recommended maximum angle from center lineI Approximately 18in.(45.7cm)recommended maximum distance BluetoothI Up to 32.8ft.(10m)communication distanceI Uses standard Windows drivers I FCC,IC,and CE approvalsProduct Data SheetJuly 2010475Field Communicator Spare Parts ListRuggedized 250Ohm Load Resistor 00275-0096-0001Rechargeable Lithium-Ion Power Module00475-0002-0022Power Supply &Charger (Li-ion/NiMH)US/UK/EU connection types included 00475-0003-0022Power Supply/Charger Standard Cord Set (US/UK/EU cords)00375-0003-0002Australian (AU)cord for Power Supply/Charger 00375-0003-0003Lead Set with connectors 00375-0004-0001Hand Strap (pack of 2)00475-0005-0002Carrying Case (with spare Hand Strap and Stylus)00475-0005-0003Magnetic Hanger00475-0005-0004Protective Rubber Boot with Stand 00475-0005-0005Stylus (pack of 2)00475-0006-0001IrDA to USB Adapter (1)00375-0015-0002System Card (SD)Reader (with USB Interface)(2)00375-0018-0022Bluetooth Adapter (1)00475-0018-0023Stand00475-0044-0001Getting Started Guide 00475-0045-3001F OUNDATION fieldbus License Via Web 00375-0142-0002Easy Upgrade (New)License via Web(3)00375-0142-0003(3)(5)AMS Device Manager Field Communicator Interface Kit (25tags)AW7005HC00025AMS Device Manager Field Communicator Interface Kit (100Tags and above)AW7005HC20000(1)Can be used to support communication between the 475and the Easy Upgrade Programming Utility or AMS Device Manager (with Handheld Communicator Interface Kit.IrDA or Bluetooth communication is required to register the 475and use the Online Licensing system.(2)The System Card (SD)Reader allows a user to upgrade a System Card much faster than when using IrDA or Bluetooth.Due to file size constraints,major upgrades require the use of a card reader.(3)The Easy Upgrade feature allows users to add new System Application software and Device Descriptions (DDs)to the 475for a period of 3years.To upgrade without this feature,the System Card must be sent to a Service Center and the upgrade will be completed for a fee.(4)The Field Communicator Online Licensing system is available to end users but it may also be performed by an agent on the user's behalf.It is at the agent's discretion if an additional fee should apply.Any order must be accompanied by the System Card S/N.Instant notification available licenses for download can be provided to email addresses provided at time of order.For more details,see the Online Licensing procedure at (5)The ReNew option is available on System Cards where the Easy Upgrade license has been expired for less than 90days.Date of expiration can be obtained by inter facing the 475with v1.6.0(or higher)of the Easy Upgrade Programming Utility.(6)Requires AMS Device Manager (v6.2or higher).Both AMS Device Manager and the Handheld Communicator Interface Kit are available for sale through select channels only.See for more details.Page 7475Field Communicator©2010,Emerson Process Management.The contents of this publication are presented for informational purposes only,and while every effort has been made to ensure their accuracy,they are not to be construed as warranties or guarantees,express or implied,regarding the products or services described herein or their use or applicability.All sales are governed by our terms and conditions,which are available on request.We reserve the right to modify or improve the designs or specifications of our products at any time without notice.All rights reserved.AMS,Fisher,FIELDVUE,and ValveLink are mark of one of the Emerson Process Management group of companies.The Emerson logo is a trademark and service mark of Emerson Electric Co.All other marks are the property of their respective owners.Emerson Process Management Asset Optimization Division 12001Technology DriveEden Prairie,MN 55344USA T 1(952)828-3206F 1(952)828-3006Product Data SheetJuly 2010475Field Communicator475Field Communicator Ordering Information475Field Communicator (1)P Rechargeable Lithium-Ion Power Module Code Power Supply/Charger1Power Supply and Charger NiMH/Li-Ion (US/UK/EU connection types included)(3)9Not included (4)Code Language E English D German J Japanese R RussianCode Product CertificationsKL ATEX,FM,CSA and IECEx Intrinsically Safe (includes FISCO as applicable)NA No Approval Code Easy UpgradeU Easy Upgrade (3year)Option (5)9Not IncludedCode Standard OptionsGMGraphics (included at No Charge)(6)Device Configuration Management (included at No Charge)(7)Code Bluetooth T Bluetooth Communication (8)9No Bluetooth Communication Code Options A Spare Rechargeable Lithium-Ion Power Module (9)S Protective Rubber Boot with Stand Typical HART Model Number:475H P 1E KL U GMT S Typical HART/Fieldbus Model Number:475F P 1E KL U GMT S(1)Base Model 475includes Field Communicator unit with Color LCD display,System Card,leadset with connectors,carrying case,Getting Started Guide,Resource CD,stylus,and straps.(2)Must specify Easy Upgrade Option (Code U)when ordering this model option.(3)To obtain an Australia power cord,order part number 00375-0003-0003.(4)This option should only be considered if the user already has a 375or 475Power Supply/Charger.If it is a 375Power Supply /Charger,it must be the Li-Ion/NiMH version.(5)The Easy Upgrade capability allows users to add new System Application software and Device Descriptions (DDs)to the 475for a period of 3years.To upgrade without this feature,the System Card would have to be sent to a Service Center.(6)The Graphics functionality enables a user to access enhanced grapical features when using the HART or F OUNDATION fieldbus application.(7)Device Configuration Management provides the capablity to store in excess of 1,000configurations and print them.(8)Bluetooth enables communication to a PC via the Bluetooth protocol.(9)A fully charged Lithium-Ion Power Module is capable of delivering power for 20hours of typical field use.If requirements exceed this specification,a Spare Power Module (code A)should be specified.。
Series 475 Mark III数字气压计用户手册说明书

SERIES 475 MARK III DIGITAL MANOMETERMADE IN U.S.A.475-000-F M 475-00-F M BATTERY INSTALLATIONRemove the two screws holding the bottom endcap and remove it. Connect the battery to the enclosed battery clip, observing correct polarity.When replacing the cover be sure the rubber sealing gasket is properly seated in the gasket channel of the endcap. Note the endcap will only fit one way.The holes are slightly offset to center. Replace the screws, DO NOT OVERTIGHTEN.LOW BATTERY INDICATORA weak battery can cause improper operation or inaccurate measurements. When the low batindicator is illuminated replace the battery. Do not leave exhausted battery in the unit due to the risk of leakage.475-AV AIR VELOCITY KITComplete kits include a Series 475 manometer(standard ranges as shown on back of card), (2) No. A-303 static pressure tips, (2) nine ft. lengths of 3/16î I.D. rubber tubing, a Model 166-6-CF , 6î Pitot tube, No. A-397 step drill, No. A-532 air velocity slide chart and instruction bulletin H-11. All items are packed in a tough molded plastic carrying case with die cut foam liner.475-0-F M475-1-F M 475-2-F M 475-3-F M 475-4-F M 475-5-F M 475-6-F M 475-7-F M475-8-F MCOPYRIGHT 2003 DWYER INSTRUMENTS, FR. 02-443041-00 Rev. 9C475-00-FM 0-4.00 IN W.C. (0-.995 kPa) 5 PSIG (35 kPa)475-0-FM 0-10.00 IN W.C. (0-2.49 kPa) 5 PSIG (35 kPa)475-1-FM 0-19.99 IN W.C. (0-4.97 kPa)10 PSIG (68.9 kPa)475-2-FM 0-40.0 IN W.C. (0-9.95 kPa)10 PSIG (68.9 kPa)475-3-FM 0-199.9 IN W.C. (0-49.7 kPa)30 PSIG (207 kPa)475-4-FM 0-10 PSID (0-.689 bar)30 PSIG (207 kPa)475-5-FM 0-19.99 PSID (0-1.378 bar)60 PSIG (4 bar)475-6-FM 0-30.00 PSID (0-2.07 bar)60 PSIG (4 bar)475-7-FM 0-100 PSID (0-6.89 bar)150 PSIG (10 bar)475-8-FM0-150 PSID (0-10.34 bar)150 PSIG (10 bar)MODEL PRESSUREMAX PRESSURE 475-000-FM 0-1.00 IN W.C. (0-.249 kPa)10 IN W.C. (2.5 kPa)OPERATING INSTRUCTIONSOn/Off OperationPress the I/O key to switch the unit on and off.Pressure unit selectionPress the E/M key to switch between english or metric units.Zeroing pressure unitsPotential inaccuracy due to temperature effects can be minimized by re-zeroing immediately before each use. To zero the display, vent both pressure ports to atmosphere. Adjust the knob on top until the displayreads exactly zero.OverpressureExceeding the range of the manometer will not damage it or affect calibration if the maximum pressure is not exceeded. Do not exceedthe maximum rated pressure established for your specific manometer model. Doing so will cause permanent damage to the sensor and may rupture the housing and/or cause injury. The maximum pressure is shown on the rear label of the manometerand on these instructions.PHONE: 219-879-8000 FAX: 219-872-9057 e-mail: info@ DWYER INSTRUMENTS, INC.102 HIGHWAY 212, MICHIGAN CITY, IN. 46360Service: Air and combustible, compatible gases.Wetted Materials: Consult Factory.Accuracy: +/-0.5% F .S., 60 to 78°F (15.6 to 25.6°C); +/-1.5% F .S. from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C).Pressure Hysteresis: +/-0.1% of full scale.Pressure Limits: See chart.Temperature Limits: 32 to 104°F (0 to 40°C).Storage Temperature Limits: -4 to 176°F (-20 to 80°C).Display: 0.5˝ liquid crystal. 3-1/2 digits.Resolution: See chart.Power Requirements: 9 volt alkaline battery (Up to 100 hours of operation). Battery not connected.Weight: 10.8 oz. (306 g).Connections: Two barbed connections for use with 1/8˝ (3.18 mm) or 3/16˝ (4.76mm) I.D. tubing. Two compression fittings for use with 1/8˝(3.18 mm) I.D. x 3/16˝ (4.76 mm) O.D. tubing for 475-7-FM and 475-8-FM.Agency Approvals: FM, CE.Size: 6-9/16˝ H x 2-13/16˝ W x 29/32˝ DSPECIFICATIONS:。
联想 G470 G475 G570 G575 说明书

3
第 1 章:了解您的電腦
左側視圖 -----------------------------------------------------------------------------------------------------
1
2
3
4
5
6
a Kensington 插槽 在此處安裝機械鎖 (未隨附)。
12
第 2 章:基本常識
取出電池組
如果您長時間不使用電腦,或是需要將電腦送到 Lenovo 維修等,請取出電腦 的電池組。取出電池組前,請確定電腦已關機。
處理電池
如果更換為類型不正確的可重新充電的電池組,可能會有爆炸的危險。電池組 含有少量的有害物質。若要避免造成人員傷害和環境危害的可能,請注意下列 事項。 • 僅更換 Lenovo 推薦類型的電池。 • 請讓電池組遠離火源。 • 請勿讓電池組外曝在水或雨中。 • 請勿嘗試拆解電池組。 • 請勿讓電池組發生短路。 • 請勿讓小孩取得電池組。 • 不可將電池組丟置於以掩埋方式處理的垃圾堆中。請依據當地法令或規範,
開啟電腦
按下電源按鈕開啟電腦。
設定作業系統
第一次使用時,您可能需要設定作業系統。設定程序可能包括以下步驟。 • 接受使用者授權合約 • 設定網際網路連線 • 註冊作業系統 • 建立使用者帳號
10
第 2 章:基本常識
使電腦進入睡眠狀態或關機
當您結束使用電腦時,可以使電腦進入睡眠狀態或關機。 使電腦進入睡眠狀態 如果只是短時間不使用電腦,使電腦進入睡眠狀態。 當電腦處於睡眠狀態時,您可以跳過啟動程式,快速喚醒電腦恢復使用。 若要使電腦進入睡眠狀態,請執行下列一項動作: • 按一下 ,然後從開始選單中選擇睡眠。 • 按下 Fn + F1。
hart475手操器中文说明书

目录第一章简介 (2)第二章基本使用 (3)2.1现场通讯器的基本性能和功能 (3)2.2开机注意事项 (4)2.3键区的使用和说明 (5)第三章在线操作菜单 (6)3.1检测菜单 (6)3.1.1轮询检测 (6)3.1.2按轮询号检测 (7)3.1.3选择设备类型 (7)3.2压力变送器主菜单 (8)3.2.1过程变量 (8)3.2.2组态与测试 (9)3.2.3特征化 (12)3.2.4 校准 (19)3.2.5显示模式 (21)3.2.6通用格式化 (22)3.3电磁流量计主菜单 (23)3.4涡街流量计主菜单 (23)3.5靶式流量计/浮筒液位计主菜单 (23)3.6金转流量计主菜单 (23)3.7通用主菜单 (23)第四章故障排除 (24)4.1故障介绍和排除方法 (24)4.2提示界面 (25)附一 (27)附二 (28)第一章简介感谢您使用本现场通讯器,本通讯器适合HART协议智能变送器的通讯操作,与HART275、HART388、HART375 兼容,具有极好的兼容性,可通讯1151,3051,EJA,ABB及流量方面的HART协议的进口仪表。
完全兼容国产的各种HART协议智能变送器。
该手册介绍了现场通讯器基本的使用、连接和操作方面的内容以及故障的排除和在使用过程中应该注意的事项。
在使用本现场通讯器之前,请阅读该该操作手册,为了更好发挥该产品的最佳性能,在使用或维修本产品之前,请深入掌握相应的内容。
如若设备需要维修,请联系我们公司。
我们将竭尽所能为您服务第二章基本使用2.1现场通讯器的基本性能和功能手操器—.台电池(机内)一块包一个充电器一部通讯线缆一条操作手册一本250欧姆电阻一支该设备配备:-可编辑修改-2.2开机注意事项在开机前,请确保以下几点:-该现场通讯器没有物理机械损坏-电池已充满电。
-将现场通讯器连接到回路(如图2-2)-回路中串有250欧姆的电阻启动现场通讯器在启动前请保证该设备已充好电。
HART475手操器英文说明书

FIELD COMMUNICATORJIANGSU BOOST INSTRUMENT SCIENCE AND TECHNOLOGY CO.,LTDCHAPTER Ⅰ Introduction (2)CHAPTER Ⅱ Basic use (3)2.1 Field communicator basic performance and functions (3)2.2 Power Considerations (4)2.3 Key areas of use and instructions (5)CHAPTER Ⅲ menu online operation3.1 Test menu (6)3.1.1 Always poll (6)3.1.2 Ask before polling (7)3.1.3 Select the type (7)3.2 PRESS TRANS MAIN MENU (8)3.2.1 Process variables (8)3.2.2 Diagnostics and service (9)3.2.3 Characterization (11)3.2.4 Calibration (17)3.2.5 Display mode (19)3.2.6 General format (20)3.3 ELECTROMAGNETIC FLOWMETER MAIN MENU (20)3.4 VORTEX FLOWMETER MAIN MENU (20)3.5 FARGET FLOWMETER/ FLOAT LEV GAUGE MAIN MENU (20)3.6 METAL ROTAMETER MAIN MENU (20)3.7 GENERAL MAIN MENU (21)CHAPTER Ⅳ Troubleshooting (21)4.1 Description and remedy fault (21)4.2 Windows for warning (22)Appendix I (24)Appendix II (25)Appendix Ⅲ (31)CONTENTSCHAPTER Ⅰ IntroductionThank you for using HART475 Field Communicator, Communicator for the HART Communication protocol smart transmitter operation, and HART275, HART375,HART475 compatible with excellent compatibility, communication 1151,3051,EJA, ABB and flow aspects of the HART protocol imported instruments. Completely and yung made a variety of smart transmitters.The manual describes the basic use of field communication device, connection and operation in Content as well as troubleshooting and in the course should pay attention.Field Communicator using the HART475, please read the manual, In order to better play to the best performance of the product in use or maintenance of the product Before understanding of the appropriate content.Should the equipment needs repair, please contact our company. We will do our best to for you.The device is equipped with:a manual operatorBattery aPack aA chargerA communication cableManual aA 250 ohm resistorCHAPTER Ⅱ Basic use2.1 Field communicator basic performance and functionsCommunicatecableBatterydisplayDisplayFourkeysnavigationPV KeyEnterON/OFFAlphanumeric keypadCharger connectorLeft -right selectionkeyField Communicator2.2 Power ConsiderationsIn turn, ensure the following:* The Field Communicator is no mechanical damage* Battery is fully charged.* The Field Communicator to connect to the circuit (Figure 2-2) * String loop resistance of 250 ohms+··Power —+-Figure 2-2Start Field CommunicatorBefore starting to ensure that the device is fully charged. Start holding down the power key until To the bright LCD screen, a successful boot.CloseSuch as to close the Field Communicator, hold the key to open up their show off, shutdown complete.2.3 Key areas of use and instructionsOpen keyThe key is used to enable or disable the Field Communicator. Arrow navigation keysFour navigation arrow keys provide menu options. Press the right arrow navigation key to enter a menu of specific options. Press Left navigation key to return to the previous menu, up and down navigation keys can be cut down in the menu Change. In the character input mode digital down navigation keys can be used as a backspace key. EnterAfter entering the menu, you can modify the contents of the LCD's bottom Line will automatically display the "Edit" to modify the words For you press the Enter key, the change was successful.Alphanumeric keyboardCharacter numeric keypad to enter characters, numbers and other symbols, numbers, and he has Characters in both input modes, field communication device according to the need to select the appropriate input mode.To enter numbers, press the number directly to where the keys to enter characters, according to the word Character position on the keyboard, first pressA key, then press the characterkey is located. For example, to enter the character "A", the first Press the left selection key, then press the number 1 character keyboard.PV keyMonitoring real-time variable shortcuts, view real-time pressure, current, percentage, Temperature, frequency and other real-time variable. Digital input mode, the character, the key is invalid.CHAPTER Ⅲ menu online operation3.1 Detection menuHow to poll:2.Ask Bef PollFigure 3-13.1.1 Polling DetectionSelect the menu, Field Communicator polling numbers from the polling numbers from 0 to 15 followed by detection equipment, if detected, the device will automatically detect the transmitter and the station number(Figure 3-1-1), press the right navigation key to enter the device type selection menu (Figure3-1-2); if not Have detected the device does not detect the transmitter will appear warning.TRANS detected:TAG No[DS8001]Figure 3-1-13.1.2 Detection by poll numbersSpecified number of polling devices to detect, according to the up and down navigation keys Choose between 0 to 15 polling numbers, then press the right navigation key to start the test (test results If the same as Figure 3-1-1).3.1.3 Select Device Type1. Pressure Transmitter2 electromagnetic flowmeter3. Vortex Flowmeter4. Target Flowmeter / float level gauge5. Turn meter gold6 General menuSelect the type:2.Electromagnetic Flow meter3.Vortex Flowmeter4.Target Flowmeter / FloatLEV gauge5.Metal Rotameter6. General MenuWhen choosing the type of equipment must be selected according to the type of field device into a specific menu, if you select the type does not match the actual type, will cause an error. If the site becomes non-pressure equipment, electromagnetic, vortex, target-style, gold transfer device is connected into the general menu. Press the down navigation key to select the device type, then press the right navigation key to enter the selected device type detection, and enter the corresponding menu, if you select the type does not match with the test will be prompted.3.2 Pressure Transmitter Main MenuSubmenu1 Process Variable2 Configuration and testing3 Characterization4 Calibration Main menu:2.DIAG and Service 3.Characterization5 Display Modes6 common formatFigure 3-2-13.2.1 Process VariableReal-time display of pressure transmitter, the percentage of current, temperature and other parameters (Figure 3-2-2). Press the left navigation button for 3 seconds before the bounce out of real-time variable monitoring model.PRESS AO PC –0.2584.8205.127KpamA%TEMP 19.570 ℃3.2.2 Configuration and TestingDIAG and Service 2.Loop Test Submenu:1. Equipment Testing2. Loop test3. Basic Settings4. User range3.Basic setup Figure 3-2-3 3.2.2.1 Test equipmentTesting equipment status, if everything is normal, liquid crystal display "device normal", if wrong, will be a warning.3.2.2.2 Loop TestDetection of the D / A current output. First, a series ammeter in the circuit, and then type a 4-20mA current between the values into the transmitter, the transmitter will automatically output the current value type, if the type of value and ammeter display values are not equal, current fine-tuning to be done.3.2.2.3 Basic SettingsSubmenu:1. Unit2. Write Protect3. DampBasic Setup 2.Write Protect 3.Damping 4. Output5. Device Information6. Polling numbersFigure 3-2-4 UnitChange the primary variable units and display units. Provide MPa, Kpa, Pa, InH2O, InHg, psi, g / cm ², kg / cm ², FtH2O, torr,ATM, mmH2O, mmHg, Bar, mBar these 15 units. When the unit of measure on behalf of the Not recognize the number will automatically display "No" means that the unit "unknow". Repair Change methods, see the menu tree.Write ProtectRead-write device protection status, when the write-protected, the transmitter can not change the internal data. DampRead-write device damping coefficient (rounded to three decimal places). Seconds.OutputRead-write device output. Divided into linear, square root, and the unknown. The default is linear.Device InformationRead and write tag number, date, descriptor, message, final assembly numberPolling numbers3.2.2.4 User rangeUser Range2.Provide pressureFigure 3-2-5Keyboard inputSelect this menu, the first prompt sensor range, then enter the range of the setup menu, press the down navigation key to select zero or range, then enter the user needs to set the value (rounded to three decimal places), then press the right navigation key into the transmitter.Sensor Range L –180.000KPa H 180.000KPa User RangeL –180.000KPa H 180.000KPaFigure 3-2-6 Figure 3-2-7Provide pressure valuesPressure on the current value with the transmitter zero and span settings, press the up and down navigation keys, press the right navigation key to confirm.Provide Pressure2.RangeFigure 3-2-83.2.3 CharacterizationSubmenu:1 .Sensor trim2. Sensor measuring range3 user range4.K coefficient5 Formatting Characterization 2.Sensor range 3.User range6 small-signal removal7 Device Address8. Data Backup9. Data RecoveryThe menu will seriously affect the operation of the transmitter to work and accuracy, so enter this menu, you need to enter the authentication password (Figure 3-2-10).Please input password:******Figure 3-2-10The default password is: 6666663.2.3.1 Sensor trimSensor Trim2.Low Range Trim3.High Range TrimFigure 3-2-11Zero trimAfter the pressure transmitter with 0 to select this operation, the transmitter automatically adjust zero.Low fine-tuningTo increase low-pressure transmitter (in KPa), type the applied pressure values (rounded to three decimal places), thetransmitter automatically corrected, so that the output value of the applied pressure.High-end fine-tuningTo the transmitter plus high pressure (in KPa), type the applied pressure values (rounded to three decimal places), the transmitter automatically corrected, so that the output value of the applied pressure.3.2.3.2 Sensor RangeSensor Range2.Madify rangeFigure 3-2-12Select the rangeFirst select the type of sensor, and then select the range of the sensor code, then press the Enter key into the transmitter. (Figure 3-2-13,3-2-14)Sensor type Range Code[DP ][5]Figure 3-2-14Figure 3-2-13Modify RangeFirst select the range sensor code, then enter the code in the range of the scale. Note: The input pressure is measured in Pa, can only enter a positive integer. Change and then select the sensor range.3.2.3.3 User rangeKeyboard inputSelect this menu, the first prompt sensor range, then enter the range of the setup menu, press the up and down navigation key to select zero or range, then enter the user needs to set the value (rounded to three decimal places), enter and press the right navigation key to send into the transmitter.Sensor Range User RangeL –180.000KPa H 180.000KPa L –180.000KPaH 180.000KPaFigure 3-2-16Figure 3-2-15Provide pressure valuesPressure on the current value with the transmitter zero and span settings, press the up and down navigation keys, the right navigation key to confirm.pressProvide Pressure2.Range3.2.3.4 K factorLow-end need to be done, do high-end.K-factor2.High RangeFigure 3-2-18Low RangeAdd 0 to the pressure transmitter, type 0 in the increase of pressure, press the right navigation key into the transmitter, the transmitter automatically adjust the k-factor low.High RangeAdded to the positive terminal of a pressure transmitter (close to or equal to the physical range), the pressure increases the pressure must be greater than 0, type in the increase of pressure values (rounded to three decimal places, units KPa), press the right navigation key into the transmitter device, the transmitter automatically adjusts the k-factor high.Note: K factors must be operated in positive pressure conditions, and the input unit KPa.3.2.3.5 FormatFull-scale formatNote: This action will seriously affect the accuracy of the transmitter, the user is best not to make their own format.How-to: give added pressure transmitter (pressure points must be positive from the negative pressure up to maximum pressure), then enter the applied pressure (Figure 3-2-19, note: do the negative pressure side formatting , the input pressure to a minus sign in front.), then press the right navigation key to format it, after a successful return to the next point format, an unsuccessful return warning.All of range:01PRESS:[ ]PaFigure 3-2-19InterpolationAfter the ultra-poor calibration point format.Note: This action will seriously affect the accuracy of the transmitter, the user is best not to make their own format.How-to: give added pressure transmitter, and then enter the increase of pressure. (Note: do the formatting in the negative pressure side, the input pressure to a minus sign in front). Press the right navigation key, the interpolation done at this time point measured the pressure should be basically equal to the applied pressure.InterpolationPRESS:[ ]PaFigure 3-2-203.2.3.6 Small-signal removalThis function is to eliminate the zero drift. Enter the number of users than the extreme range.3.2.3.7 Device addressView a device's address. Device address is the unique identification number the smart board.3.2.3.8 Data BackupData backup: the value of the current user scale and format all the data back to FLASH the database, this function is to facilitate data recovery after a mistake. Click the menu "Backup" button3.2.3.9 Data RecoveryData Recovery: The instrument factory, manufacturers have the formatting operation on the instrument, and the correct data formatted to do a backup, misuse of the instrument when the user does not work, you can use the "Data Recovery" function of its error Content removal operation, and re-manufacturers will re-initialize the backup data is written instrument, easy instrument to restore the original data. Click the menu "Data Recovery" button.3.2.4 CalibrationCalibrationSubmenu2.Output Trim1 Sensor trim2 Output TrimFigure 3-2-213.2.4.1 Sensor trimSensor Trim2.Low Range Trim3.High Range TrimZero trimAfter the pressure transmitter with 0 to select this operation, the transmitter automatically adjust zero.Low fine-tuningTo increase low-pressure transmitter (in KPa), type the applied pressure values (rounded to three decimal places), the transmitter automatically corrected, so that the output value of the applied pressure.High-end fine-tuningTo the transmitter plus high pressure (in KPa), type the applied pressure values (rounded to three decimal places), the transmitter automatically corrected, so that the output value of the applied pressure.3.2.4.2 Output TrimOutput fine-tuning needs to be a precision ammeter in series to the circuit, into the fine-tuning, the LCD will prompt access ammeter, the current fine-tuning exit, the LCD will prompt recovery circuit.Warning:Please access circuitammeter!Figure 3-2-234mA current fine-tuningChoose 4mA current fine-tuning, the output should be 4.000mA, if the ammeter shows the value is not equal to 4.000mA, select "No", an input box, type the ammeter showsthe input box value (rounded to three decimal places), then press right navigation key to enter the current value into the transmitter, the transmitter will automatically calibrate the current output, the output of 4.000mA, if a less than satisfactory results, repeat this operation.(Note: The meter accuracy should be higher than the output precision of the table)Output Trim2. Trim DAC GainFigure 3-2-2420mA current fine-tuning4mA current methods of operation and fine-tuning the same. 3.2.5 Display Mode1.%Select this mode, the transmitter displays the percentage.ER SETSelect this mode, the transmitter displays the user settings. ER SET &%Select this mode, the transmitter displays the percentage of user settings and are displayed alternately every 4S.4.INPUT PRESSSelect this mode, the transmitter only the input pressure.5.INPUT PRESS &%Select this mode, the transmitter displays the percentage of input pressure and alternating every 4S.Display Mode2.USER SET3. USER SET&%Figure 3-2-253.2.6 General FormattingGeneral Format: (known as three, five-point format)This menu requires a password to enter the default password is 666666.(1) Select the instrument type and range of code to determine the instrument's physical range.(2) in the common format into the format, the original plate for 1151 current 22mA, the order of the physical range of 0%, 60%, 100% three-point format, or 0%, 60%, 100%, -60%, 100% five-point format. Communication device according to the first line shows the calculation of the percentage range of physical pressure, the pressure and the input Fill pressure (in Pa), right-click until the pressure stabilized first sent.(3) operation is successful, display the percentage of the next point, to continue or exit.Operation failed (such as the pressure increases the pressure and display the corresponding percentage difference too large to return to this point redo. Done 100% in three-point format according to exit after completion of five-point format at 100% done automatically exit. withdrawal of current from 22mA into a measurement of current.3.3 Electromagnetic Flowmeter Main MenuSee photos3.4 Vortex FlowmeterSee photos3.5 Target Flowmeter / float level gaugeSee photos3.6 meter gold transferSee photos3.7 Common main menuSee photosRemarks:The handheld contains vortex flowmeter, the target flowmeter, flow meter gold turn, Common menu and menu operation is similar to the electromagnetic flow meter, this is not setting them in, with Please refer to the distribution of body attached page menu menu tree operation.CHAPTER Ⅳ Troubleshooting4.1 Introduction and troubleshooting faultsIt does not really startIf in the course can not be switched, that can not start the Field Communicator, First check the battery. Should the battery power is still not start, there may be on-site Communication device to open the key is damaged. (Note: Please do not use the process of firm Hard thing to touch the buttons Field Communicator film to avoid damage. )Communication or communications are not interrupted If there is no communication on the first check HART field device loop and voltage. Almost all field devices have at least 4mA and 12VDC to Victoria maintain normal operation.Check the loop impedance, to see whether the access loop 250 ohm external Impedance. Access to 250 ohm resistors, will lead 250 ohm resistor at both ends of the access. And then view the communication is normal.Check the terminal and HART communications cable is damaged.HART communication by the control system interference. At this point stop control system HART communication, recognition and communication between the field device communication.4.2 Tips interfaceLow battery warningWhen the battery voltage is low, top right of the LCD display will flash a battery-shaped pattern.TAG No(DS8001)OnlinePRESS AO0.0064.000KpamAFigure 4-2-1Communication Failure WarningWhen the Field Communicator to the transmitter with the communication failure warning (Figure 4-2-2).Warning:Communication interruption!Check the equipmentFigure 4-2-2Date Input ErrorAllows you to enter a date range January 1, 1900 to December 31, 2155, when the input is not in the range of dates, enter the error message will appear (Figure 4-2-3), note the date input format xxxx xx xx day in May.Date entered incorrectlyFigure 4-2-3Data entry errorsWhen the input parameter is incorrect when the prompt appears, such as the removal of only a small signal input is an integer, if you enter a negative number, an error message will appear (Figure 4-2-4).Entered incorrectly!Appendix I: General menu list of unit typesNo. Unit No. Unit No.3 Unit No.4Unit1 InH2O2 InHg mmH2O mmHg5 9psikg/cm2ATML/S6 barPa7 mbarkPa8 g/cm2torr10141811151912162013 17 L/minm3/sm3/h℃m/smv21 25 29 33Ωm3minv22263034Hzm23273135mAcmh24283236Lmm%spH kg MT37 41 45lb 384246STg/h394347LT 404448g/skg/minlb/s g/minkg/hkg/sMT/min MT/h49 lb/min 50 lb/ h 51 ST/min 52 ST/h53 57 61 65 69 LT/hkg/lL/hKJ5458626670g/cm3g/l5559636771kg/m3m/h5660646872g/mlm3/minKJ/hNm3/hMJ/hMPaNm3/minMJ GJ/h GJ None NoAppendix II: various types of equipment menu tree Pressure Transmitter menu tree:Electromagnetic Flowmeter menu tree:Vortex Flowmeter menu tree:Target Flowmeter / float level gauge menu tree:Gold transfer meter menu tree:Common menu tree:Appendix 3: GlossaryAlphanumericAlphanumeric character set, often including other character sets, such as punctuation marks.Device configurationDefine the physical properties and operating characteristics of the device parameters. Does not include dynamic data.Device DescriptionWritten in the HART Foundation fieldbus devices instruction set, the device description language of the host application and the HART or FOUNDATION fieldbus device communication parameters, and methods of instruction are defined.Field EquipmentIn addition to HART digital communication signal, the field device can generate or receive analog signals.HART devicesUsing the HART protocol for information communication equipment.HART LoopOne communication network, the master and slave devices are HART smart or HART compatible devices.HART protocolAddressing a high-speed remote communications protocol converter. One for the digital add-type 4-20mA communications and intelligent field devices, industry-standard protocols.PollOne kind of query the network in order to determine the method that the device online.。
HART475黑白屏中文说明书

目录第一章简介 (2)第二章基本使用 (3)2.1现场通讯器的基本性能和功能 (3)2.2开机注意事项 (4)2.3键区的使用和说明 (5)第三章在线操作菜单 (6)3.1检测菜单 (6)3.1.1轮询检测 (6)3.1.2按轮询号检测 (7)3.1.3选择设备类型 (7)3.2压力变送器主菜单 (8)3.2.1过程变量 (8)3.2.2组态与测试 (9)3.2.3特征化 (12)3.2.4校准 (19)3.2.5显示模式 (21)3.2.6通用格式化 (22)3.3电磁流量计主菜单 (23)3.4涡街流量计主菜单 (23)3.5靶式流量计/浮筒液位计主菜单 (23)3.6金转流量计主菜单 (23)3.7通用主菜单 (23)第四章故障排除 (24)4.1故障介绍和排除方法 (24)4.2提示界面 (25)附一 (27)附二 (28)附三 (34)第一章简介感谢您使用HART现场通讯器,本通讯器适合HART协议智能变送器的通讯操作,与HART275、HART375、HART475兼容,具有极好的兼容性,可通讯1151,3051,EJA,ABB及流量方面的HART协议的进口仪表。
完全兼容国产的各种智能变送器。
该手册介绍了现场通讯器基本的使用、连接和操作方面的内容以及故障的排除和在使用过程中应该注意的事项。
在使用HART现场通讯器之前,请阅读该该操作手册,为了更好发挥该产品的最佳性能,在使用或维修本产品之前,请深入掌握相应的内容。
如若设备需要维修,请联系我们公司。
我们将竭尽所能为您服务。
该设备配备:手操器一台电池一块包一个充电器一部通讯线缆一条操作手册一本250欧姆电阻一支第二章基本使用2.1现场通讯器的基本性能和功能现场通讯器示图开/关键数字字母按键区显示区PV 键左中右选择键四个导航键确认键充电器接口通讯电缆电池显示2.2开机注意事项在开机前,请确保以下几点:·该现场通讯器没有物理机械损坏·电池已充满电。
hart475手操器中文说明书

目录第一章简介⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯2第二章基本使用⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯32.1 现场通讯器的基本性能和功能⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯32.2 开机注意事项⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯42.3 键区的使用和说明⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯5第三章在线操作菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯63.1 检测菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯6 3.1.1 轮询检测⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯6 3.1.2 按轮询号检测⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯7 3.1.3 选择设备类型⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯73.2 压力变送器主菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯8 3.2.1 过程变量⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯8 3.2.2 组态与测试⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯9 3.2.3 特征化⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯12 3.2.4 校准⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯19 3.2.5 显示模式⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯21 3.2.6 通用格式化⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯223.3 电磁流量计主菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯233.4 涡街流量计主菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯233.5 靶式流量计 /浮筒液位计主菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯233.6 金转流量计主菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯233.7 通用主菜单⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯23 第四章故障排除⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯244.1 故障介绍和排除方法⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯244.2 提示界面⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯25附一⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯27 附二⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯⋯281第一章简介感谢您使用本现场通讯器,本通讯器适合 HART 协议智能变送器的通讯操作,与 HART275 、HART388 、 HART375 兼容,具有极好的兼容性,可通讯 1151,3051,EJA,ABB 及流量方面的HART 协议的进口仪表。
hart475手操器中文说明书32774

目录第一章简介 (2)第二章基本使用 (3)2.1现场通讯器的基本性能和功能 (3)2.2开机注意事项 (4)2.3键区的使用和说明 (5)第三章在线操作菜单 (6)3.1检测菜单 (6)3.1.1轮询检测 (6)3.1.2按轮询号检测 (7)3.1.3选择设备类型 (7)3.2压力变送器主菜单 (8)3.2.1过程变量 (8)3.2.2组态与测试 (9)3.2.3特征化 (12)3.2.4校准 (19)3.2.5显示模式 (21)3.2.6通用格式化 (22)3.3电磁流量计主菜单 (23)3.4涡街流量计主菜单 (23)3.5靶式流量计/浮筒液位计主菜单 (23)3.6金转流量计主菜单 (23)3.7通用主菜单 (23)第四章故障排除 (24)4.1故障介绍和排除方法 (24)4.2提示界面 (25)附一 (27)附二 (28)第一章简介感谢您使用本现场通讯器,本通讯器适合HART协议智能变送器的通讯操作,与HART275、HART388、HART375兼容,具有极好的兼容性,可通讯1151,3051,EJA,ABB及流量方面的HART协议的进口仪表。
完全兼容国产的各种HART协议智能变送器。
该手册介绍了现场通讯器基本的使用、连接和操作方面的内容以及故障的排除和在使用过程中应该注意的事项。
在使用本现场通讯器之前,请阅读该该操作手册,为了更好发挥该产品的最佳性能,在使用或维修本产品之前,请深入掌握相应的内容。
如若设备需要维修,请联系我们公司。
我们将竭尽所能为您服务。
该设备配备:手操器一台电池(机内)一块包一个充电器一部通讯线缆一条操作手册一本250欧姆电阻一支第二章 基本使用2.1 现场通讯器的基本性能和功能现场通讯器示图开/关键数字字母按键区显示区PV 键 左中右选择键四个导航键 确认键 充电器接口通讯电缆电池显示2.2开机注意事项在开机前,请确保以下几点:·该现场通讯器没有物理机械损坏 ·电池已充满电。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
现 在 有 了 便 利 升 级 功 能,当 新 的 HART 和Ff现 场 总 线 设 备 描 述 文 件 (DDs)发布时, 只需要从互联网直接 下载就可以升级475现场通 讯器了。 随时保持更新,一切尽在您的掌握之 中。
使用 -10°C (14°F ) 到+50°C (122°F ) 0% to 95% RH (无凝结) 从0°C (32°F) 到+50°C (122°F )
充电 10°C (32°F ) 到+40°C (104°F )
带电池储存 -20°C (-4°F ) 到+55°C (131°F )
无电池储存 -20°C (-4°F ) 到+55°C (131°F )
外壳保护级别 IP51(前部)
防撞击 测试通过1米自由落体到水泥表面
便利升级要求
使用 有Internet连接的PC CD Rom驱动器 IrDA口(或红外适配器) 蓝牙接口(或适配器) SD 读卡器(对某些升级需要) WindowsXP(SP2 或SP3)或 Windows Vista 商务版(SP1) 操作系统
键盘 共25键,包括4个动作键,12个数字字母键, tab键,功能键,背光键,电源键,和4个光标 控制(箭头)键
电池 可充电锂离子电池模块
电池运行时间 连续运行-20小时 常规使用-40小时 待机状态-80小时
电池充电器选项 输入电压100-240VAC,50-60Hz 包括电源线,插头有美国,欧洲,和英国选择
对 于HART回 路, 475现 场 通 讯 器 能 确认回路中的DC信号是否正确。
微处理器 80MHz 日立SH3
内部闪存 32MB
系统存储卡 1GB SD卡
随机内存 32MB
重量 包括电池大约1.65磅(0.75公斤)
显示 VGA(240 x 320点阵),彩色,3.5英寸(8.9cm) 透射式,触摸屏幕 防眩涂层
00275-0096-0001 00475-0002-0022 00475-0003-0022 00375-0003-0002 00375-0003-0003 00375-0004-0001 00475-0005-0002 00475-0005-0003 00475-0005-0004 00475-0005-0005 00475-0006-0001 00375-0015-0002 00375-0018-0022 00475-0044-0001 00475-0018-0023 00475-0045-3001 00475-0049-0001
2011年2月
发现阀门故障 在现场用ValveLink Mobile工具进行 阀 门 诊 断,可 以 对Fisher FIELDVUE 数字阀门控制器快速实现包括阀门 曲 线,动 态 错 误 频 段 和 阶 越 响 应 的 测试。
直观的用户界面让ValveLink Mobile 更 易 使 用 和 理 解。在 现 场 诊 断 故 障 或是传输结果到像AMS套件的设备 管理系统中可以作深入的分析并存 档。
通过便利升级选项, 可以获得最新 的HART和FF现 场 总 线 设 备 描 述 文 件(DD)。475现场通讯器, 确保通过 单一的本安手操器, 完成对HART和 现场总线仪表的通用支持。
方便的存储和打印设备组态信息,满足分析和文档的需求
2011年2月
配置便携式工作包的475现场通讯器,提供了组态和诊断HART和FF现场设备的工具
475 现场通讯器备件清单
加固型 250 欧姆负载电阻 可充电锂离子电池组 电源/充电器(可用于锂电池和镍氢电池)美/英/欧式插头 电源/充电器标准线(美/英/欧式) 电源/充电器澳大利亚制式线 带测试头的连接线 手携带 便携包(包括额外手携带和点触笔) 磁性挂钩 保护橡胶套和支架 点触笔 IrDA转USB适配器(1) 系统卡(SD)读卡器(USB接口)(2) 支架 蓝牙适配器(1) 快速启用指南 资源光盘 在线授权 (4) FF现场总线网上授权 便利升级网上授权 (3) 便利升级(更新)网上授权 (3) (5) AMS接口套件 现场通讯器AMS接口套件(25点) 现场通讯器AMS接口套件(100点及以上)
大的按钮和导航键让单手操作更加 容易,甚至可以戴着手套操作。坚固 的显示屏可以承受工厂中正常使用 时的碰撞和敲击。
电源模块也通过认证可以在危险环 境下安装。
475现场通讯器的橡胶套提供了在 现场以及工具箱中的额外保护。橡 胶套以及475的外壳也是根据本安 标准设计,能防止静电累积。
475现场通讯器的设计, 制造,和测 试都依据严格的标准。在任何地方 它都可以助您圆满完成任务。
00375-0142-0002 00375-0142-0003 00375-0142-2003
AW7005HC00025 AW7005HC20000
(1)
用于支持475和便利升级软件工具的通讯,或与AMS之间的通讯(需有AMS接口套件),475注册和在线授权系统需要用到IrDA通讯或蓝牙通讯
(2)
使用系统卡读卡器的系统升级速度比IrDA或蓝牙方式快,鉴于文件大小的限制,主要的升级要求使用读卡器
橡胶套在现场能提供额外的保护
强大的诊断功能
与AMS设备管理系统连接 AMS设备管理系统(以下简称AMS) 是工业标准的资产管理软件,475现 场 通 讯 器 与 之 完 全 兼 容。AMS在 控 制 杂 志 的 读 者 评 比 中,连 续10年 获 得标定软件的第一名。
AMS通过使用现场智能设备的信息 创 建 出 预 测 性 维 护 的 环 境。AMS允 许 您 对HART, FF现 场 总 线 和 无 线 HART的设备进行组态, 标定, 存档, 和故障诊断。
诊断网络问题
475现场通讯器能用来组态您工厂 中所有的FF现场总线设备, 使用它 可以进行现场总线网段的高效启动 和故障查找。通过诊断总线段网络 的DC电压和噪声均值, 能建立一个 符合质量要求的总线网。
通过监测网段的低频噪声, 能探测电 源问题。通过诊断通讯信号强度, 能 发现不正确的终端和出错的设备。
通过红外接口或蓝牙,475现场通讯 器与AMS之间能可以传送设备组态 数据, 携带475现场通讯器到现场更 新一个或多个设备的组态。475手操 器最多可存储多达1000个设备的组 态信息, 或传送给AMS。
475现场通讯器和AMS一起使用,能 为您所有的设备提供一个高效的管 理环境。
设备组态管理
使用便利升级工具,您可以备份成百 上千个设备的组态, 并在现场通讯 器和PC之间进行数据传送, 并且方 便地查看和打印这些组态数据以进 行分析。
2011年2月
通过 ValveLink Mobile 和增强的图形功能在现场进行高级故障诊断
便利升级 选项可使手操器一直保持 最新
475现场通讯器可由用户通过互联网 随时升级, 从而避免了因送往服务中 心所导致的时间拖延。带有便利升级 选项的手操器, 可以下载最新的设备 描述文件(DDs), 新的功能, 或直接获 得新的许可授权选项。保持 475现场 通讯器更新就是这样简单。
2011年2月 FF
中文
8
FF 总线型号
475 H P 1 E KL U GMT S 475 F P 1 E KL U GMT S
028-82928502
整 个475现 场 通 讯 器 的 重 量 分 配 均 匀, 适合现场单手操作。475基于可 靠 的Windows CE实 时 操 作 系 统。 475现场通讯器备有充足的内存,以 便 于 未 来 的 扩 展。包 括 含 有32MB的 应用内存和1GB的系统卡。
便利升级工具能在475现场通讯器和PC之间通过IrDA,蓝牙或Sd卡读卡器传送系统软件,DD文件和HART设备组态信息。
电池充电器
小型6针连接
HART和现场总线 三个4mm香蕉插头(HART和FF现场总线公 用一个)
IrDA口 IrDA(红外数据连接)口支持最高115Kbps 建议最大中线偏离角度±15 度 建议最大距离18英寸(47.5cm)左右
蓝牙接口 达到10米通讯距离 使用标准Windows驱动程序 FCC, IC和CE认证
本质安全
475现 场 通 讯 器 符 合 各 认 证 机 构 和 标准对本安的要求。所有的安全区域 认证都包含在单一的选型项中(请参 见订购选型表)
牢固可靠
被称作“现场通讯器”的一个原因就 是因为某些工作只能在仪表现场执 行。475现场通讯器是专门为工厂恶 劣工况所设计的现场通讯器,能完 成针对现场设备的任务。
(3)
便利升级选项允许用户在3年有效期内给475添加新的系统应用软件和设备描述文件(DD)。如果没有该选项,必须把系统卡送至服务中心升级,相应收取一定费用
(4)
现场通讯器的在线授权是针对最终用户的,同时代理商也可以代表用户执行,代理商决定是否收取额外费用。所有订单必须有系统卡的序列号。有效的授权可即时通过订购
475现场通讯器的设计理念在于简化 你在现场的工作。用户在操作HART 和FF现场总线设备时, 都可体验到直 观的彩色图形界面。它的触摸屏幕比 PDA或掌上电脑还大,支持 HART 协 议 版 本5, 6和 7 (包 括WirelessHART) 的设备, 并能通过互联网进行升级。
特点
触摸显示屏采用传输反射技术, 使 您无论是在阳光下还是在普通光线 中 都 能 清 晰 地 读 取 信 息。多 层 背 光 调节功能的引入, 确保屏幕能在不 同的光线条件, 甚至在厂区的昏暗 灯光下也清晰可读。
在线授权
有便利升级功能就可以进行在线授 权, 通过互联网为475现场通讯器添 加新功能。有了在线授权,例如增加 FF现场总线支持的这样强大的功能, 只需购买授权许可,便可直接下载到 您的现场通讯器。