电器图中各术语英文解释介绍

电器图中各术语英文解释介绍
电器图中各术语英文解释介绍

电器图中各术语英文解释

第一部分

GCK、GCS、MNS是低压抽出式开关柜;

GGD、GDH、PGL是低压固定式开关柜;

XZW综合配电箱;

ZBW箱式变电站;

XL、GXL低压配电柜、建筑工地箱;

JXF电器控制箱;

PZ20、PZ30系列终端照明配电箱;

PZ40、XDD(R)电表计量箱

PXT(R)K-□/□-□/□-□/□-□/IP□系列规格型号解释:

(1)PXT明装配电箱,暗装加(R)

(2)K有如表1的系列配线方式

(3)□/□额定电流/额定短时耐受电流能力:用数字表示,250/10表示:额定电流250A/额定短时耐受电流能力10kA,根据顾客要求可以降低。

(4)□/□进线型式:□/1单相输入;□/3三相输入;1/3表示混合输入

(5)□×□出线回路:单相回路×三相回路,6×3单相6回路,三相3回路

(6)□/ □主开关型式/防护等级;1/IP30单相主开关/IP30;3/IP30三相主开关/IP30

表1:

序号汉语拼音字头中文解释装配图号电气原理图号

1 JL 计量箱 PXT01 PXT01 dq系列

2 CZ 插座箱 PXT02 PXT02 dq系列

3 ZM 照明箱 PXT03 PXT03 dq系列

4 DL 动力箱 PXT04 PXT04 dq系列

5 JC 计量插座箱 PXT05 PXT05 dq系列

6 JZ 计量照明箱 PXT06 PXT06 dq系列

7 JD 计量动力箱 PXT07 PXT07 dq系列

8 ZC 照明插座箱 PXT08 PXT08 dq系列

9 DC 动力插座箱 PXT09 PXT09 dq系列

10 DZ 动力照明箱 PXT10 PXT10 dq系列

11 HH 混合功能箱 PXT11 PXT11 dq系列

12 ZN 智能箱 PXT12 PXT12 dq系列

表二:

电气箱柜名称编号规格型号

高压开关柜 AH

高压计量柜 AM

高压配电柜 AA

高压电容柜 AJ

低压电力配电箱柜 AP

低压照明配电箱柜 AL

应急电力配电箱柜 APE

应急照明配电箱柜 ALE

低压负荷开关箱柜 AF

低压电容补偿柜 ACC或ACP 直流配电箱柜 AD

操作信号箱柜 AS

控制屏台箱柜 AC

继电保护箱柜 AR

计量箱柜 AW

励磁箱柜 AE

低压漏电断路器箱柜 ARC 双电源自动切换箱柜 AT 多种电源配电箱柜 AM

刀开关箱柜 AK

电源插座箱 AX

建筑自动化控制器箱 ABC 火灾报警控制器箱 AFC

设备监控器箱 ABC

住户配线箱 ADD

信号放大器箱 ATF

分配器箱 AVP

接线端子箱 AXT

举例说明吧

例一:

GCK

第一个 G 代表配电柜

第二个 C 代表抽屉式

第三个 K 代表控制

例二:

GGD

第一个 G 代表配电柜

第二个 G 代表固定式

第三个 D 代表动力

第二部分

配电箱1LA1a 1AL1b AT-DT是什么意思还有1AP2 2AP1 3APc 7AP 1KX之类的。。。

这是工程配电系统图中各个配电盘的常用代号,由设计者自行编排,没有强制性的规范。但遵循一定的规律,AL是配电箱、AP是动力配电箱、KX是控制箱等。例如:

1AL1b——代表一层一位置的b种类配电箱;

AT-DT——电梯配电箱;

1AP2——代表一层第二位置上的动力配电箱。

GGD固定柜,便宜,单个柜子馈出回路少

GCK,GCS都是抽屉柜,价格贵点,馈出回路多,方便接线

单纯看柜体价格应该不会差很多,关键是断路器贵。

第一位,P-开启式低压开关柜

G-封闭式低压开关柜

第二位,G-固定死,C-抽出式,H-固定、抽出混装式。

第三位,L(或D)-动力用,K-控制用,S-森源电气系统,

GGD较便宜,GCS为GCK的经济型,

关于各种低压配电柜型号及意思?

GGD/M/J①②③

G-交流低压配电柜

G-电器元件固定安装,固定接线

D/M/J-D:电力用柜 M:面板操作 J:静电电容器

①-设计序号:1.分断能力为15kA;2.分断能力为30kA;3.分断能力为50kA

②-主电路方案代号

③-辅助电路方案代号

PGL □—□

P-低压开启式配电柜

G-电器元件固定安装,固定接线

L-动力用

前面□-设计序号

后面□-主电路方案号

PGL1型为15KA(有效值),PGL2型为30KA(有效值);

现在PGL已基本不用了,动力大部分采用GGD了

配电箱中的“pe、kx 、cos 、 pjs 、ijs”是什么意思? 他们之间如何换算

Pe是额定功率 Kx是需要系数 cosO是功率因数 Pjs是计算功率 Ijs是计算电流

Pjs=Pe*Kx Ijs=Pjs*1.52/cosO

RV一般用途单芯软硬导体无护套电缆

BV-70内部布线用导体温度为70℃的单芯实心导体无护套电缆 RV-70内部布线用导体温度为70℃的单芯软导体无护套电缆BV-90内部布线用导体温度为90℃的单芯实心导体无护套电缆BV-90内部布线用导体温度为90℃的单芯软导体无护套电缆

BVV轻型聚氯乙稀护套电缆

RVB扁型无护套软线

RVV轻型聚氯乙稀护套软线

RVV普通聚氯乙稀护套软件

BV铜芯聚氯乙稀绝缘电线JB8734-1998

BLV铝芯聚氯乙稀绝缘电线

BVR铜芯聚氯乙烯绝缘软电缆

BVV铜芯聚氯乙稀绝缘聚氯乙烯护套圆形电缆

BLVV铝芯聚氯乙稀绝缘聚氯乙烯护套圆形电缆

BVVB铜芯聚氯乙稀绝缘聚氯乙烯护套扁形电缆

BLVVB铝芯聚氯乙稀绝缘聚氯乙烯护套扁形电缆

RVS铜芯聚氯乙稀绝缘绞型连接用软电缆

RVP铜芯聚氯乙稀绝缘屏蔽软电线

RVP-90铜芯耐热90℃聚氯乙稀绝缘屏蔽软电线

RVVP铜芯聚氯乙稀绝缘屏蔽聚氯乙稀护套软电缆

普通型电缆型号

YJV、YJLV交联聚乙烯绝缘聚氯乙烯护套电力电缆

YJY、YJLY交联聚乙烯绝缘聚乙烯护套电力电缆

YJV22、YJLV22交联聚乙烯绝缘钢带铠装聚氯乙烯护套电力电缆YJV23、YJLV23 交联聚乙烯绝缘钢带铠装聚乙烯护套电力电缆YJV32、YJLV32 交联聚乙烯绝缘细钢丝铠装聚氯乙烯护套电力电缆

YJV33、YJLV33 交联聚乙烯绝缘细钢丝铠装聚乙烯护套电力电缆阻燃型电缆型号

在普通型电力电缆型号前加ZA、ZB、ZC

耐火型电缆型号

在普通型电力电缆型号前加N

无卤低烟型电缆型号

WDZ-YJY、WDZ-YJLY-交联聚乙烯绝缘阻燃聚烯烃护套无卤电缆WDZ-YJY22、WDZ-YJLY22-交联聚乙烯绝缘钢带铠装阻燃聚烯烃护套无卤电缆

WDZ-YJY32、WDZ-YJLY32-交联聚乙烯绝缘细钢丝铠装阻燃聚烯烃护套无卤电缆

C M 1 - 63 M / 3 300 (代号解释)

C.....................................企业特征号(常熟开关厂)

M................................ 塑料外壳式断路器

1............................. 设计序号

63......................壳架等级额定电流

M.................分断能力级别

3...........开关极数(3表示3极开关。4表示4极开关)

300....脱扣器类型(3为复式脱扣器,00表示无附件)

德力西:企业特征号一般为CD。所以对应型号为CDM1-63M/3300 正泰:企业特征号一般为N。所以对应型号为NM1-63M/3300 天正:企业特征号一般为TG。所以对应型号为TGM1-63M/3300 对于CM1可以完全这样套用,但是对于其他型号的产品一般可以按照这个来替换,但是要确保设计代号一样哟,有的按2有的厂家就会标为其他的数字(如3、4等等)。

1、隔离开关在电气回路中主要起电气隔离用,保证在维修时能

看到一个明显的断开点,它没有灭弧装置,不能接通和断开负荷、短路电流,只能在空载情况下进行拉开、闭合操作。

2、断路器有较好的灭弧装置,能开断短路电流,负荷电流。

建筑电气图纸中W3-L3-BV-450/750-3*2.5-PC16-CC.WC具体意

思,越全越好!

W3回路编号 L3相序 BV-是聚氯乙烯绝缘铜芯电线 450-导体

与屏蔽护套之间的额定工频电压有效值 750指相间导体的额定工频

电压有效值 3*2.5 3跟2.5平方毫米导线 PC16是穿外径16mm聚乙

烯电线管 CC是电线管顶板内暗敷设 WC指的是电线管墙面内暗敷

设。FC是地面或地板下敷设。PR 用塑料线槽敷设 XC BE 沿屋架或跨屋架敷设 LM

SR 用钢线槽敷设

CLE、AC 沿柱或跨柱敷设 ZM

RC 穿水煤气管敷设

WE、WS 沿墙面敷设 QM

SC 穿焊接钢管敷设 G

CE 沿天棚面或顶板面敷设 PM

TC、MC 穿电线管敷设 DG

ACE 在能进人的吊顶内敷设 PNM

PC 穿聚氯乙烯硬质管敷设 VG

BC 暗敷设在梁内 LA

FPC 穿聚氯乙烯半硬质管敷设 RVG

CLC 暗敷设在柱内 ZA

KPC 穿聚氯乙烯塑料波纹电线管

WC 暗敷设在墙内 QA

FC 暗敷设在地面内 DA

CC 暗敷设在顶板内 PA

PCL 用塑料夹敷设 VJ

CP 穿金属软管敷设 SPG

建筑电气图纸上标注BV-3*4/T20/FC,请问T是什么意思,什么导管?

T是指镀锌电线管镀锌电线管与镀锌钢管是有区别的镀锌电线管就是JDG管套接紧定式薄壁镀锌钢导管各种型号壁厚均为

1.6MM

BV-2*2.5-TC20-CC这个最后的CC是什么意思啊?

答:铜芯聚氯乙烯绝缘电线-2条2.5平方毫米电线—穿直径20电线管—在天花内或者顶棚敷设,最后的CC是暗敷在顶板内的意思。

其他说明:BV电线:1.分类和用途是用来分布电流用的,属于布电线类,用字母“B”表示; 2.导体材料是铜,用字母“T”表示,布电线中铜芯导体省略表示;3.绝缘材料为聚氯乙烯,用字母“V”表示;电线型号及名称;4.布电线结构简单,除上面三点,有的还有护套,护套材料为聚氯乙烯也用字母“V”表示;护套材料为橡胶就用字母“X”表示。没有护套以及后面没有的就不用表示。如BVV 表示铜芯聚氯乙烯绝缘聚氯乙烯护套圆型电线。

02、有时还有FC、WC之类的是表示什么个安装方式啊?

答:FC 暗敷在地面, WC 暗敷设在墙内,CC 暗敷在顶板内

其他说明:穿焊接钢管敷设:SC;穿电线管敷设:MT;穿硬塑料管敷设:PC;穿阻燃半硬聚氯乙烯管敷设:FPC;电缆桥架敷设:CT;金属线槽敷设:MR;塑料线槽敷设:PR;用钢索敷设:M;穿聚氯乙烯塑料波纹电线管敷设:KPC;穿金属软管敷设:CP;直接埋设:DB;电缆沟敷设:TC;混凝土排管敷设:CE

03、最好能解释一下BV-2*2.5-TC20-CC(FC、WC)是表示什么意思啊?

答:详见上述01回答;

04、常见的安装表示方式?

线路敷设方式:穿焊接钢管敷设:SC;穿电线管敷设:MT;穿硬塑料管敷设:PC;穿阻燃半硬聚氯乙烯管敷设:FPC;电缆桥架敷设:CT;金属线槽敷设:MR;塑料线槽敷设:PR;用钢索敷设:M;穿聚氯乙烯塑料波纹电线管敷设:KPC;穿金属软管敷设:CP;直接埋设:DB;电缆沟敷设:TC;混凝土排管敷设:CE;沿或跨梁(屋架)敷设:AB;暗敷在梁内:BC;沿或跨柱敷设:AC;暗敷设在柱内:CLC;沿墙面敷设:WS;暗敷设在墙内:WC;沿天棚或顶板面敷设:CE;暗敷设在屋面或顶板内:CC;吊顶内敷设:SCE;地板或地面下敷设:F;PR 塑料线槽敷设;PC 硬制塑料管敷设;FPC 半硬制塑料管敷设;SC 薄电线管敷设;RC 水煤气管敷设;MR 封闭式金属线槽敷设;CT 电线桥架或托盘敷设;K 瓷瓶或拄式绝缘子敷设;PCL 塑料夹敷设;CP 蛇皮管/金属软管敷设;QR 铝合金线槽敷设;PL阻燃半

硬聚乙烯管敷设;AL 铝皮线卡敷设;SR 沿钢索敷设;BE 沿屋架或跨屋架敷设;CLE 沿柱或跨柱敷设;WE 沿墙面敷设;

ACE 能进入的吊顶内敷设;CE 沿顶棚面或顶板面敷设;BC 暗敷设在梁内;C 暗敷设在柱内;WC 暗敷设在墙内;FC 暗敷在地面;CC 暗敷在顶板内;ACC 暗敷在不能进人的吊顶内要穿金属管;SCE 在吊顶内敷设要穿金属管管路敷设标注方法;SC:焊接钢管;TC:电线管镀锌或非镀锌薄钢管;PC:硬质塑料管;CT:电缆桥架;CP:金属软管;SR:钢线槽;MR: 金属线槽;RC:水煤气管;KBG:管为套接扣压式镀锌薄壁钢导管;JDG:为套接紧定式镀锌薄壁钢导管;导线敷设部位:CT:电缆桥架敷设;SR:沿钢索敷设;CLE:沿柱或跨柱敷设;WE:沿墙面敷设;CC:沿现浇板内暗敷设;CE:沿天棚面或顶棚面敷设;AC 沿或跨柱敷设;ACE:在能进入人的吊顶在敷设;SCE 吊顶内敷设;BC:暗敷设在梁内;CLC:暗敷设在柱子内;BC 暗敷设在梁内;WC:暗敷设在墙内;WE:沿墙明敷设;WS 沿墙面敷设;FC:地板或地面下敷设;CC:暗敷设在屋面或顶板内;

电线常用的表示法:RVB:平行多股软线(扁的);RVS:对绞多股软线;RVV:多股软线……

05、CC是由哪两个单词首字母抽出来的?

Concealed in Ceiling or slab(藏在天花板或板)。

概述

CH系列模数化终端电器主要包括:CH1、CH2系列小型断路器,CH2Z

系列小型直流断路器, CH1L、CH2L系列漏电断路器, CH1G系列隔离开关,CH1A系列模数化插座及各系列产品附件。它们广泛用于工业、商业及民用等各个领域。

●线路过流保护装置

CH1、CH2系列小型断路器符合GB10963、IEC60898(其中CH2-125符合GB14048.2、IEC60947-2),具有单极+中性极、单极、二极、三极和四极,额定电流范围为1A-125A,最大短路分断能力10kA,适用于配电电路的短路、过载保护及线路的不频繁转换。

CH2Z系列小型直流断路器符合GB10963.2、IEC60898-2,具有单极和二极,额定电流范围为1A-63A,最大短路分断能力10kA,适用于直流配电电路的短路、过载保护及线路的不频繁转换。

●线路过流和漏电保护装置

CH1L、CH2L系列漏电断路器符合GB16917.1、IEC 61009-1(其中CH2L-100符合GB14048.2、IEC60947-2),具有单极+中性极、二极、三极、三极+中性极和四极,额定电流范围为1A-100A,最大短路分断能力10kA,适用于配电电路的短路、过载保护,同时可对人体直接或间接接触、线路或负载对地漏电等故障进行保护。

●隔离开关

CH1G系列隔离开关符合GB14048.3、IEC60947-3,具有单极、二极、三极、四极,额定电流范围为32A-100A,用来对建筑物和类似场所的线路设施、工业配电系统和电动机电路作隔离之用。

●模数化插座

CH1A系列模数化插座符合GB2099.1、IEC60884-1,额定电压至440V,额定电流至25A的固定式插座,装于模数化终端配电箱和其它成套电器箱内,对用电设备进行插接。

●汇流排

汇流排是CH1-63、CH2-63小型断路器的一种模数化附件,具有单极、二极、三极,适用于多台断路器同相位进线端之间的联接,也可以作为一种通用化的标准附件用于同相位终端电器间的联接。

电气英语翻译

Heat sink 散热器 Forward conduction 正向导通 Thyristor 晶闸管 Solid-state power device 固态功率器件 Silicon wafer 硅片,硅晶片 Self-latching 自锁 电流额定值current rating 反向击穿电压reverse breakdown voltage 负电流脉冲negative current pulse 交流电动机相位控制phase control AC motor 反向并联二极管reverse shunting diode 正信号positive signal Gate-turn-off thyristors 可关断晶闸管 固态功率器件基础 2.1 引言 在这一章中我们重点讨论固态功率器件,并且只讨论它们在相位控制或频率控制的三相460V交流鼠笼式感应电动机的应用。 2.2 固态功率器件 应用于固态交流电动机控制的功率半导体主要的五个类型如下: (1)二极管 (2)晶闸管(例如:硅控整流器SCRs) (3)(电子)晶体管 (4)可关断晶闸管 (5)双向可控硅 硅控整流器和双向可控硅通常用于相位控制。各种各样的二极管制品、硅控整流器、电子晶体管和可开断晶体管都应用于速度控制。这些器件的共性是:利用硅晶体薄片层层堆叠构成PN结的各种组合。在二极管、硅控整流器和可关断晶闸管中,P结常被叫作阳极,N结常被叫做阴极,在电子晶体管中相应的被叫做集电极和发射极。这些器件的区别在于导通和关断的方法及电流和电压的容量。 让我们来简答看一下这些器件,了解一下他们的参数。 2.2.1 二极管 图2.1是一个二极管。左边是一个中间有硅晶片的PN结,右边是单个二极管的表示符号。当阳极为正阴极为负时,会有电流通过,二极管本身伴随着一个比较小的压降。当极性相反时,只有很小的反向漏电流通过,这在图2.2中有表现出来。正向压降一般是1V左右,与电流额定值无关。 (PN结阳极阴极单个二极管PN结和表示符号) 二极管的正向电流额定值取决于起大小和设计,而这二者是根据器件的散热要求来确定的,一保证掐进不超过最大结温(通常是200℃)。 反向击穿电压(见图2.2)是二极管的另一个重要参数,它的数值较二极管尺寸大小更多地取决于其内部设计。

安全防护行业专业英语术语【全】

安全防护行业专业英语术语第1页 安全防护行业专业英语术语第1页 火灾警报alarm of fire 火灾警报器fire alarm sounder 火灾警报装置fire alarm device 火灾事故fire accident 火灾探测和报警fire detection and alarm 火灾探测器fire detector 火灾探测设备fire detection equipment 火灾危害性fire hazard 火灾危险fire danger/fire peril 火灾危险性fire risk 火灾显示盘fire indicating panel 火灾现场scene of fire 火灾寻视器firefinder 火灾自动报警系统automatic fire alarm system 火灾自动报警系统效用试验operational test for automatic fire alarm system 机器处所的固定低膨胀泡沫灭火系统low-expansion foam fire extinguishing system in machinery space 机器处所的固定高膨胀泡沫灭火系统high-expansion foam fire extinguishing system in machinery space 机械控烟mechanical smoke control 集中火灾报警控制器central fire alarm control unit 假火警false alarm of fire 间接扑火indirect fire suppression 减光型光电感烟火灾探测器obscuration-type photoelectric smoke detector 检烟系统smoke detection system 脚面罩metatarsal guard 截流管嘴shutoff nozzle 紧急出口escape exit 紧急信号emergency signal/urgency signal 警报alarm 警报阀alarm valve 警报器alarm 警报信号alarm signal 警报信号器alarm annunciator 警报信号系统alarm system 警笛alarm whistle/police whistle 警铃alarm bell 警惕装置vigilance device 警钟alarm bell

电气英文文献+翻译

POWER SUPPLY AND DISTRIBUTION SYSTEM ABSTRACT The basic function of the electric power system is to transport the electric power towards customers. The l0kV electric distribution net is a key point that connects the power supply with the electricity using on the industry, business and daily-life. For the electric power, allcostumers expect to pay the lowest price for the highest reliability, but don't consider that it's self-contradictory in the co-existence of economy and reliable.To improve the reliability of the power supply network, we must increase the investment cost of the network construction But, if the cost that improve the reliability of the network construction, but the investment on this kind of construction would be worthless if the reducing loss is on the power-off is less than the increasing investment on improving the reliability .Thus we find out a balance point to make the most economic,between the investment and the loss by calculating the investment on power net and the loss brought from power-off. KEYWARDS:power supply and distribution,power distribution reliability,reactive compensation,load distribution

安全专业英语词汇

Unit 1 safety management system Accident causation models 事故致因理论 Safety management 安全管理Physical conditions 物质条件Machine guarding 机械保护装置 House-keeping 工作场所管理Top management 高层管理人员 Human errors 人因失误Accident-proneness models 事故倾向模型 Munitions factory 军工厂 Causal factors 起因Risking taking 冒险行为Corporate culture 企业文化 Loss prevention 损失预防Process industry 制造工业Hazard control 危险控制Intensive study 广泛研究Organizational performance 企业绩效 Mutual trust 相互信任Safety officer 安全官员 Safety committee 安全委员会Shop-floor 生产区Unionized company 集团公司Seniority 资历、工龄Local culture 当地文化Absenteeism rate 缺勤率Power relations 权力关系Status review 状态审查 Lower-level management 低层管理者 Business performance 组织绩效Most senior executive 高级主管Supervisory level 监督层Safety principle 安全规则Wall-board 公告栏Implement plan 执行计划Hazard identification 危险辨识Safety performance 安全性能 Unit 2 System Safety Engineering System safety engineering 系统安全工程 By-product 附带产生的结果 Engineering practice 工程实践Safety problem 安全问题Accelerating technology 快速发展的技术 Safety effort 安全投入System’s life cycle 系统的生命周期 System effectiveness 系统有效性Logical reasoning 逻辑推理Potential accident 潜在事故Accident cause 事故原因 Logical programming 合理的规划System hazard 系统危害 Safety input 安全投入Inherently safe system 本质安全系统 Schedule delays 进度拖延Concept phase 初步计划阶段 Safety criteria 安全标准Government regulations 政府管制System operation 系统运行System analysis 系统分析System design 系统设计 Aid in 有助于 Equipment specifications 设备说明Maintenance plans 维护计划Safety problems 安全问题Development phase 发展阶段Operation phase 运行阶段Performance reviews 绩效评估Disposal phase 处理阶段Intuitive process 直觉过程

电气专业英语翻译

Foundation of PLC 1. The central processing unit Although referred to as the brain of the system, the Central Processing Unit in a normal installation is the unsung hero, buried in a control cabinet, all but forgotten. 2. Basic Functionality In a programmable controller system, the central processing unit(CPU) provides both the heart and the brain required for successful and timely control execution. It rapidly and efficiently scans all of the system inputs, examines and solves the application logic, and updates all of the system outputs. In addition, it also gives itself a checkup each scan to ensure that its structure is still intact. In this chapter we will examine the central processing unit as it relates to the entire system. Included will be the various functional blocks in the CPU, typical scan techniques, I/O interface and memory users, power supplies, and system diagnostics. 3. Typical Function Block Interactions In practice, the central processing unit can vary in its architecture, but consists of the basic building block structure illustrated in Fig.1.1.The processing section consists of one or more microprocessors and their associated circuitry. While it is true that some of the luxury of using microprocessors, most modern systems use either a single microprocessors such as the AMD 2903, usedin a bit slice architecture. This multiple microprocessor system to break the control system tasks into many small components which can be executed in parallel. The result of this approach is to achieve execution speeds that are orders of magnitude faster than their single-tasking counterparts. In addition to efficiently processing direct I/O control information and being programmable, the real advantage that microprocessor-based system have over their hardwired relay counterparts is the ability to acquire and manipulate numerical data easily. It is this attribute that makes programmable controllers the powerhouses that they are today in solving tough factory automation problems. The factory of tomorrow will run efficiently only if quality information about process needs and status of the process equipment are known on a realtimes basis. This can and will come about only if the unit level controllers, including programmable controllers, are empowered with the ability to collect, analyze, concentrate, and deliver data about the process. As the

安全英文术语解释

DEFINITIONS AND ABBREVIATIONS Safety: a state in which the risk of harm or damage will affect life, property and environment is limited to an acceptable level. SAFETY: 安全是对人类的生命、财产、环境可能产生的损害控制在人类能接受水平以下的状态。 Environment: Surroundings in which an organization operates, including air, water, land, natural resources, foliage, fauna, humans, and their interrelation. 环境:组织运行活动的外部存在,包括空气、水、土地、自然资源、植物、动物和人,以及它们之间的相互关系。 HSEMS: health, Safety and Environment Management System. HSEMS:健康、安全和环境管理体系 HSE inspection: A practical check performed at regular intervals regarding the general HSE status at the work site. HSE 检查:在合适时间间隔内进行的作业现场实际总体HSE 状况的检查。 Hazard: The potential to cause harm, including ill health or injury; damage to property, plant, products or the environment; production losses. 危害: 可能导致人员伤害、财产/工厂/产品/环境破坏、生产损失的潜在因素。HAZID: Hazard Identification (HAZID) is a systematic examination related to design or operation. The technique is used to identify problem areas and actions to be taken along with responsibilities and planned due dates. HAZID:危害识别(HAZID)是一种对设计和作业所做的系统的检查技术。该技术用来识别什么地方会出现问题、应采取的措施、责任部门(人)和采取措施的时间。 Risk: is defined as a combination of the frequency of occurrence (likelihood) of an undesired event, and the severity of the consequences (effects) of that event. Risk – a hazard associated with the work which potentially can cause damage to personal and/or property. 风险:风险的定义是发生特定危害事件的可能性与发生该事件的后果的严重性的结合。 Risk Analysis: Use of available information to identify hazards and to estimate the risk. 风险分析:通过可利用的信息,识别危害并计算其风险。 Near-miss: Any event which had the potential to cause injury and/or damage and/or loss, but which was avoided by circumstances. 未遂事件:任何可能会造成人员伤亡、环境破坏、或/和财产损失,但由于种种原因没有发生那些后果的事件。

家用电器说明文

电冰箱 在我们家里,有许许多多家用电器,它们给我们生活带来了生活中的便利。但我自己还是喜欢我家那台电冰箱,它不但外表好看,功能作用也不少。 电冰箱“身穿”乳白色的外衣,像一位白衣天使,稳稳地站在墙脚。给人以素雅清新的感觉。它比我还高一头呢!它是长方形的,高约两米,宽约半米。 冰箱分为两层:上层是冷冻室,下层是冷藏室。当你打开冷冻室的门,一股薄薄的 `轻纱般的“雾气”迎面扑来,让人感到丝丝两意,是那么清晰,那么舒服。里面存放剩饭`剩菜,还有两个制冰盒。烈日炎炎,我和姐姐常常把自制冰放进里面,或者从这里拿出一块冰摸一摸,凉快凉快。 冷藏室的功能可多呢,可以冷藏许多食品:冷藏室分为三层:第一层是由一个窝一个窝的小洞组成,用来放鸡蛋,鸡蛋放那儿既稳当又保鲜;第二层妈妈用来放鸡`鸭`鱼`肉等美味佳肴`小吃。冷藏使食物新鲜,不变质;第三层可以放些饮料`水果`饼干等小食物,放在上面,馋得我直留口水。 听了我的介绍,您一定会认为我家的电冰箱本领不小吧!它可是我家的好帮手。 家用电器作文400字二:家用电器—洗衣机

我们在平时,常常会听到人们在谈家用电器。比如说“洗衣 机”、“电冰箱”等的话题。你们知道“洗衣机”是怎么回事吗? 其实,我们所说的“洗衣机”就是在我们生活中,实用、耐用的家用电器。你们肯定知道“洗衣机”就是用一些普通的塑料和铁质零件和全自动的发动零件制成的。可是,你们可别小看这“洗衣机”,他们则作用可别提多大了。“洗衣机、洗衣机”其实就是帮助我们洗干净衣服、裤子和其它一些床单等等。 以前人都是用手洗净衣服,而“洗衣机”就像是老天带给我们的神圣礼物帮助我们生活,比如说,我们用“洗衣机”洗干净一件衣服,根本不用我们用手洗,只要直接把脏衣服放进“洗衣机”中,一按开关在加上一小匙洗衣粉就可以洗干净衣服了。这可比我们用手洗净衣服快多了。 “洗衣机”不仅有洗干净衣服的功能还能把洗干净的衣服自动放进烘干盆中去,主动烘干衣服,这样衣服只要拿出就干了,而且带一阵阵清香呢! 可以这样说“洗衣机”和我们的生活息息相关,只要有了它,我们生活就会感到快乐、方便。 家用电器作文400字三:我家的电器 我家有许多电器,有洗衣机、电视机、电风扇等。 我先介绍我家的洗衣机。我家的洗衣机胖墩墩的,像个大怪物。它

建筑电气英文翻译

建筑电气 电气工程设计包括两个主要的设计方面。主要是一部分的电能的转换及分配和电力的供配、照明系统、防雷接地系统。一般来说,建筑主要的变化包括:高压和低压配电系统、变压器、备用电源系统。电力系统包括配电和控制,室内和室外照明系统包括所有类型的照明,防雷系统包括入侵波防护、闪电传感器、接地、等电位连接和局部等电位连接等。辅助等电位连接等。在短短的20年里,系统在技术和产品的面貌发生了翻天覆地的变化。许多的设计理念也发生了巨大的变化。开关设备如高压系统的第一个断路器油断路器,后来油断路器的逐步发展,不仅规模大,但是一般都包含油物质。由于开关设备尺寸较大,我们还必须建立独立的设备房间,占据了大量的建筑面积。现在真空断路器和六氟化硫断路器,不仅体积小,而且短路容量大,外壳尺寸远小于原来的橱柜,并且断路器没有任何油,防火性能大大提高。而且断路器和其他低压设备在一个房间里,这样即节省空间又方便管理。过去大容量的低压断路器,短路电流容量逐渐变大,规模也逐渐变小,而且更加稳定,使系统运行更加安全可靠,为设计带来了方便。向着智能化低压断路器方向发展,断路器各种参数可以通过总线工业控制,信号直接传输到计算机。 干式变压器的出现,对建筑电气设计带来了极大的方便,因为没有变压器油泄漏和火灾的可能性,以便它可以很容易地安装在建筑本身,甚至直接到负荷中心。它还消除变压器对油的需求限制,构建大容量设备时可以使用干式变压器。在实际工程设计中曾应用四个台湾2500kVA干式变压器。 在使用紧急发电机方面,从性能和尺寸的角度来看,比过去进步很多。除了使用柴油发电机;应急照明使用EPS备用电源;中断供电在一个毫秒以内的设备,可以使用UPS。 电力设备的控制从单一元件的控制到控制继电器控制变化。除了更好的性能的各种组件的规模较小,也降低控制箱的规模。由于数字技术更多的运用于控制能达到最佳的控制状态来控制设备。进一步提高了节能的效果。 照明系统从过去单一光源、灯具和低效率的状态向更广泛的前景发展。建筑中使用的光源可供选择的品种数量很多。光的发光效率和色调在向着高效的方向发展,灯具不断地改进其效率和不同形式的灯具运用于不同场合。例如,普通的荧光灯镇流器由普通的镇流器向节能型镇流器方向发展。还对谐波组件的大小进行精简,生产低谐波电子镇流器。许多措施如配件和灯具的使用,可以满足设计要求,同时能实现不同的体系结构、照明要求的各种场所。无论照明和室内装饰照明还是道路照明和户外庭院建筑的光照明,所有的都展示了照明技术的发展和建筑照明的好处与便利。

电气专业术语中英对照

一.电气名词Electric items 二.线路(母线、回路)Lines (Bus , circuits) 三.设备Equipments 四.保护、继电器Protection , relays 五.电气仪表Electric instruments 六.防雷Lightning protection 七.接地Grounding , earthing 八.室、所Room , Substation 九.电修车间设备Equipments of electric repair 十.材料Material 十一.图名Drawings , diagrams 十二.表头Tables 十三.标准图词汇Terms from standard DWG 一.电气名词Electric items 交(直)流Alternating (direct) current 短路电流Short-circuit current 起始次暂态短路电流Initial subtransient short-circuit current 冲击电流Impulse current 稳态短路电流Steady state short-circuit current 临界电流Critical current 切断电流Rupturing current 熔断电流Blow-out current 故障电流Fault current 计算电流Calculating current 极限有限电流Limit effective current 过电流Over current 逆电流Inverse current 整定电流Setting current 额定电流Rated current 电流密度Current density 短路电流最大有效值Maximum effective value of short-circuit current 高压High-voltage , High-tension 低压Low-voltage , Low-tension 计算电压Calculating voltage 激磁电压Exciting voltage 冲击电压Impulse voltage 临界电压Critical voltage

电气专业术语中英文对照

一.电气名词 Electric items 二.线路(母线、回路)Lines (Bus , circuits) 三.设备 Equipments 四.保护、继电器 Protection , relays 五.电气仪表 Electric instruments 六.防雷 Lightning protection 七.接地 Grounding , earthing 八.室、所 Room , Substation 九.电修车间设备 Equipments of electric repair 十.材料 Material 十一.图名 Drawings , diagrams 十二.表头 Tables 十三.标准图词汇 Terms from standard DWG 一.电气名词 Electric items 交(直)流 Alternating (direct) current 短路电流 Short-circuit current 起始次暂态短路电流 Initial subtransient short-circuit current 冲击电流 Impulse current 稳态短路电流 Steady state short-circuit current 临界电流 Critical current 切断电流 Rupturing current 熔断电流 Blow-out current 故障电流 Fault current 计算电流 Calculating current 极限有限电流 Limit effective current 过电流 Over current 逆电流 Inverse current 整定电流 Setting current 额定电流 Rated current 电流密度 Current density 短路电流最大有效值 Maximum effective value of short-circuit current 高压 High-voltage , High-tension 低压 Low-voltage , Low-tension 计算电压 Calculating voltage 激磁电压 Exciting voltage 冲击电压 Impulse voltage 临界电压 Critical voltage 残留电压 Residual voltage 击穿电压 Puncture voltage 脉动电压 Pulsating voltage 供电电压 Supply voltage 电力电压 Power voltage

安全英语 专业词汇

专业词汇 1、上海海事大学Shanghai Maritime University 2、海洋科学与工程学院College of Ocean Science and Engineering 3、美国安全工程师协会American society of safety engineers 4、职业安全与健康Occupational safety and health OSH 5、职业健康与安全管理局Occupational Safety and Health Administration 6、安全、健康和环境safety, health and environmental (SH&E) 7、职业安全与健康法案Occupational Safety and Health Act 8、安全工程Safety Engineering 9、安全行业Safety Profession 10、安全专家(安全专业人员)Safety Professional 11、安全实践(安全业务)Safety Practice 12、安全科学Safety Science 13、损失预防Loss Prevention 14、损失控制Loss Control 15、危险Hazard 16、风险Risk 17、危险识别Hazard recognition /Hazard identification 18、危险分析Hazard analysis 19、防灾Hazard prevention 20、减灾Hazard reduction 21、火灾隐患Fire hazard 22、辐射危害Radiation hazard 23、危险评估Hazard assessment/evaluation

电气自动化专业毕业论文英文翻译

电厂蒸汽动力的基础和使用 1.1 为何需要了解蒸汽 对于目前为止最大的发电工业部门来说, 蒸汽动力是最为基础性的。 若没有蒸汽动力, 社会的样子将会变得和现在大为不同。我们将不得已的去依靠水力发电厂、风车、电池、太阳能蓄电池和燃料电池,这些方法只能为我们平日用电提供很小的一部分。 蒸汽是很重要的,产生和使用蒸汽的安全与效率取决于怎样控制和应用仪表,在术语中通常被简写成C&I(控制和仪表 。此书旨在在发电厂的工程规程和电子学、仪器仪表以 及控制工程之间架设一座桥梁。 作为开篇,我将在本章大体描述由水到蒸汽的形态变化,然后将叙述蒸汽产生和使用的基本原则的概述。这看似简单的课题实际上却极为复杂。这里, 我们有必要做一个概述:这本书不是内容详尽的论文,有的时候甚至会掩盖一些细节, 而这些细节将会使热力学家 和燃烧物理学家都为之一震。但我们应该了解,这本书的目的是为了使控制仪表工程师充 分理解这一课题,从而可以安全的处理实用控制系统设计、运作、维护等方面的问题。1.2沸腾:水到蒸汽的状态变化 当水被加热时,其温度变化能通过某种途径被察觉(例如用温度计 。通过这种方式 得到的热量因为在某时水开始沸腾时其效果可被察觉,因而被称为感热。 然而,我们还需要更深的了解。“沸腾”究竟是什么含义?在深入了解之前,我们必须考虑到物质的三种状态:固态,液态,气态。 (当气体中的原子被电离时所产生的等离子气体经常被认为是物质的第四种状态, 但在实际应用中, 只需考虑以上三种状态固态,

物质由分子通过分子间的吸引力紧紧地靠在一起。当物质吸收热量,分子的能量升级并且 使得分子之间的间隙增大。当越来越多的能量被吸收,这种效果就会加剧,粒子之间相互脱离。这种由固态到液态的状态变化通常被称之为熔化。 当液体吸收了更多的热量时,一些分子获得了足够多的能量而从表面脱离,这个过程 被称为蒸发(凭此洒在地面的水会逐渐的消失在蒸发的过程中,一些分子是在相当低的 温度下脱离的,然而随着温度的上升,分子更加迅速的脱离,并且在某一温度上液体内部 变得非常剧烈,大量的气泡向液体表面升起。在这时我们称液体开始沸腾。这个过程是变为蒸汽的过程,也就是液体处于汽化状态。 让我们试想大量的水装在一个敞开的容器内。液体表面的空气对液体施加了一定的压 力,随着液体温度的上升,便会有足够的能量使得表面的分子挣脱出去,水这时开始改变 自身的状态,变成蒸汽。在此条件下获得更多的热量将不会引起温度上的明显变化。所增 加的能量只是被用来改变液体的状态。它的效用不能用温度计测量出来,但是它仍然发生 着。正因为如此,它被称为是潜在的,而不是可认知的热量。使这一现象发生的温度被称为是沸点。在常温常压下,水的沸点为100摄氏度。 如果液体表面的压力上升, 需要更多的能量才可以使得水变为蒸汽的状态。 换句话说, 必须使得温度更高才可以使它沸腾。总而言之,如果大气压力比正常值升高百分之十,水必须被加热到一百零二度才可以使之沸腾。

电气工程及其自动化专业英语翻译

电气工程及其自动化专业英语翻译.Electric Power Systems. The modern society depends on the electricity supply more heavily than ever before. It can not be imagined what the world should be if the electricity supply were interrupted all over the world. Electric power systems (or electric energy systems), providing electricity to the modern society, have become indispensable components of the industrial world. The first complete electric power system (comprising a generator, cable, fuse, meter, and loads) was built by Thomas Edison –the historic Pearl Street Station in New York City which began operation in September 1882. This was a DC system consisting of a steam-engine-driven DC generator supplying power to 59 customers within an area roughly 1.5 km in radius. The load, which consisted entirely of incandescent lamps, was supplied at 110 V through an underground cable system.. Within a few years similar systems were in operation in most large cities throughout the world. With the development of motors by Frank Sprague in 1884, motor loads were added

安全专业术语解释.

安全专业术语解释 ◆安全生产方针:“安全第一、预防为主、综合治理”。 ◆瓦斯治理十二字方针:“先抽后采、以风定产、监测监控”。 ◆探放水十六字原则:“预测预报、有疑必探、先探后掘、先治后采”。 ◆瓦斯排放二十字要领:“从外向里、逐段排放、错口对接、由小到大、循序渐进”。严禁“一风吹”排放瓦斯。 ◆两个责任主体和两个负责制:政府是安全生产的监管主体,企业是安全生产的责任主体;政府行政首长负责制和企业法定代表人负责制。这两个责任制是我国安全生产工作的基本责任制度。 ◆双基两化工作:“基层建设、基础工作”和“安全质量标准化、采掘机械化”工作。 ◆两型三化矿井:“安全高效型、本质安全型”和“基础管理精细化、技术装备现代化、人员培训制度化”矿井。 ◆一通三防:通风、防瓦斯、防火、防尘。 ◆一炮三检制:装药前、放炮前、放炮后检查瓦斯浓度。 ◆三人联锁放炮制:班长、*****工、瓦斯检查员“三人”联锁进行放炮。放炮前,*****工将警戒牌交给班长,由班长指定专人警戒,下达放炮命令,并将自己携带的放炮命令牌交给瓦斯检查员,瓦斯检查员经检查瓦斯、煤尘合格后,将自己携带的放炮牌交给*****工,*****工发出放炮口令,并吹哨进行放炮,放炮后三牌各归原主。 ◆雨季三防:防署、防讯、防雷电。 ◆冬季三防:防冻、防火、防中毒。 ◆瓦斯爆炸三条件:瓦斯浓度在爆炸界限内,一般为5%—16%;混合气体中的氧气浓度不低于12%;有足够能量的点火源,一般为650℃—750℃。 ◆煤尘爆炸三条件:煤尘本身具有爆炸性,且煤尘浮游在空气中并达到一定浓度(45g-2000g/m3);有能引起爆炸热源的存在(610℃-1050℃);氧气浓度不低于18%。 ◆三大保护:供电系统(包括小型电器)的过流保护、接地保护和漏电保护。 ◆三反意识:隐患查处用脑反思、施工质量用眼反查、措施落实用口反问。 ◆化学品:指各种化学元素、由元素(单质)组成的化合物及其混合物,包括天然的或者人造的。 ◆危险化学品:指具有易燃、易爆、有毒、有害、腐蚀及放射特性,会对人员、设施、环境造成伤害或损害的化学品,均属危险化学品。

电气专业英语翻译

第八章 第一节燃煤发电厂 在化石燃料电厂中 煤 石油和天然气在炉内燃烧 燃烧产生的热能将水加热并把它转化为蒸汽 蒸汽用来驱动与发电机机械耦合的涡轮机。典型燃煤发电厂的示意图如图8-1所示。将发电厂的运行过程简单描述如下。煤从储煤场取出后送入磨煤机 从磨煤机出来的煤粉与预热过的空气混合后吹入炉内燃烧。包含一套复杂管道和汽包的炉子叫做锅炉 水泵将水送入锅炉 在锅炉内 水的温度上升直到蒸发成蒸汽。蒸汽流向涡轮机 燃烧烟气在送入机械和静电除尘器除去99%的固体颗粒 灰 后派往烟囱。上面描述的以煤粉 空气和水作为输入以蒸汽作为输出的单元可以叫做蒸汽发生单元 锅炉或蒸发器。当考虑燃烧过程时 常用术语“锅炉” 而考虑水—汽循环时 常用“蒸发器”一词。典型压力为3500psi 温度为1050度F的蒸汽通过关断阀门和控制阀门送给汽轮机 蒸汽的热能由汽轮机转化为机械能。从汽轮机出来的乏汽在一个叫做“冷凝器”的热交换器内冷却 然后作为给水再次送回锅炉。控制阀门允许汽轮发电机组通过调节蒸汽流量而改变输出功率。关断阀门起一个保护作用 正常时它是全开的 如果电气输出功率突然降低 由于断路器动作 他可以突然关断以防止汽轮发电机超速 但此时控制阀门不关闭。图8-1所示为“单级”汽轮机 但实际中采用更为复杂的“多级”布置以获得相对高的热效率。图8-2所示为代表性的“多级“布置汽轮机示意图。在这个多级布置中 四个蒸汽压力不同的涡轮机在机械以级联的排列形式连接在一起。在惯常的的流程中 从锅炉 过热器 出来的高压蒸汽进入高压 HP 缸。蒸汽从高压缸出来被送回锅炉的再热器 然后送入中压 IP 缸。蒸汽离开中压缸后 压力很低体积膨胀很大 被送入低压 LP 缸。从低压缸出来的乏汽在冷凝器中被冷却 然后作为锅炉给水用从汽轮机中抽出的蒸汽预热后 通过给水泵送回锅炉。燃煤发电厂的净效率通常低于40% 也就是煤的化学能转化成电能的比例低于40% 。尽管这个数字与大约30%的工业平均值相比具有一定的优越性 但是超过60%的化石燃料能量被转化为废热。

常用安全名词解释

安全名词解释 1.“三违”:指违章指挥、违章操作、违反劳动纪律。 2.四不放过:事故原因分析不清不放过;事故责任者和群众没有受到教育不放过;没有采取切实有效的防范措施不放过;事故责任者没有被处理不放过。 3.三同时:生产经营单位新建、改建、扩建工程项目的安全设施,必须与主体工程同时设计、同时施工、同时投入生产和使用。 管理:整理、整顿、清扫、清洁、修养(素养)、安全。 5.新工人的三级教育:入厂教育、车间教育、岗位(班组)教育。 6.工业“三废”:废水、废气、废渣。 7.安全标志:禁止标志(红色)、警告标志(黄色)、指示标志(蓝色) 8.车辆保养制度的“三检”:出车前检查、行车中检查、回场后检查。 9.十大不安全心理因素:侥幸、麻痹、偷懒、逞能、莽撞、心急、烦躁、赌气、自满、骄傲。 10.我国安全生产方针:“安全第一,预防为主”。 11.三不伤害:不伤害自己、不伤害别人、不被别人伤害。 12.我国消防工作方针:“预防为主,防消结合”。 13.车辆“三交一封”:交准驾证、交行车证、交车钥匙、停封车辆。 14. 三品:易燃品、易爆品、化学危险品 15. 八懂:懂规章制度和责任;懂岗位技术的规定;懂安全生产的方针和政策;懂设备构造和性能;懂工艺流程和原理;懂防火常识和规定;懂尘毒危害和治理;懂伤亡事故报告的规定。 16. 四会:会操作维护和保养;会排除故障和预防;会正确使用防护用品,会防火救火和报警。 17. 事故构成要素:人、物、自然环境和社会环境 18. 民用爆炸物品:爆破器材,包括各类炸药、雷管、导火索、导爆索、非电导爆系统、起爆药和爆破剂等;黑火药、烟火剂、民用信号弹和烟花爆竹。 19. 安全电压:对于比较干燥而触电危险性较大的环境,国际电工标准协会规定安全电压为50V以下,我国规定安全电压为36V。对于潮湿而又触电危险性较大的环境,国际电工标准协会规定为25V以下,我国则规定为12V。对于在游泳池或其他因触电导致严重二次事故的环境,国际电工标准协会规定为2.5V以下,我国无规定。一般认为,这种环境的安全电压可采用3V。 20. 职业禁忌症:是指不宜从事某种作业的疾病或解剖、生理状态。在该状态下接触某些职业性危害因素时可导致下列情况:①使原有疾病病情加重。②诱发潜在疾病。③影响子代健康。④对某种职业危害因素易感、较易发生该种职业病者。

相关文档