安费诺先进传感器推出IPT2000压力变送器

合集下载

安诺精密 SmartLine STA800 绝对气压传感器说明书

安诺精密 SmartLine STA800 绝对气压传感器说明书

SmartLineIntroductionPart of the SmartLine® family of products, the STA800 and STA80L are high performance absolute pressuretransmitters featuring piezoresistive sensor technologycombining pressure sensing with on chip temperaturecompensation capabilities providing high accuracy, stability and performance over a wide range of applicationpressures and temperatures. The SmartLine family is also fully tested and compliant with Experion® PKS providing the highest level of compatibility assurance and integrationcapabilities. SmartLine easily meets the most demandingapplication needs for pressure measurement applications..Best in Class Features:•Accuracies up to 0.0375% of span standard &0.025% of span optional.•Stability up to 0.01% of URL per year for 15 years. •Automatic temperature compensation. •Rangeability up to 100:1.•Response times as fast as 80ms.•Multiple local display capabilities.•External zero, span, & configuration capability. •Polarity insensitive electrical connections. •Comprehensive on-board diagnostic capabilities. •Integral Dual Seal design for highest safety based on ANSI/NFPA 70-202 and ANSI/ISA 12.27.2.•Full compliance to SIL 2/3 requirements.•Modular design characteristics.•Available with additional 15-year warranty. •Plugged Impulse Line Detection Option.•Supports NAMUR NE-107 Extended Diagnostics (FF). •Dual/Triple Calibration Option (HART & Fieldbus Only).Figure 1 – STA800 Absolute Pressure Transmitters feature field-proven piezoresistive sensor technology Communications/Output Options:•4-20mA•Honeywell Digitally Enhanced (DE)•HART ® (version 7.0)•FOUNDATION™ FieldbusAll transmitters are available with the above listedcommunications protocols.Span & Range Limits:2 STA800 Smart Pressure TransmitterDescriptionThe SmartLine family of gauge pressure, differential pressure, and absolute pressure transmitters is designed around a high performance piezo-resistive sensor. This one sensor actually integrates multiple sensors linking process pressure measurement with on-board static pressure (DP Models) and temperature compensation measurements resulting in the best total performance available. This level of performance allows the ST 800 to replace virtually any competitive transmitter available today. (√)Unique Indication/Display OptionsThe ST 800 modular design accommodates a standard alphanumeric LCD display or a unique advanced graphics LCD display with many unparalleled features.Standard LCD Display Features•Modular (may be added or removed in the field). •Supports HART protocol variant.•0, 90,180, & 270 degree position adjustments.•Four configurable screens.•Standard and custom measurement units available. •Display calculated flow (square root) value in addition to analog output signal.• 2 Lines 6 digits PV (9.95H x 4.20W mm) 8 Characters. •Write protect Indication.•Built-in Basic Device Configuration through Internal or External Buttons – Range/Engineering Unit/Loop Test/Loop Calibration/Zero /Span Setting.•Multiple language capabilities (EN, RU).Advanced Graphics LCD Display Features•Modular (may be added or removed in the field). •0, 90, 180, & 270-degree position adjustments. •Standard and custom measurement units available. •Up to eight display screens with 3 formats are possible.•Large PV with Bar Graph or PV with Trend Graph. •Configurable screen rotation timing (1 to 30 sec). •Display calculated flow (square root) value in addition to analog output signal.•Unique “Health Watch” indication provides instant visibility of diagnostics.•Multiple language capability (EN, DE, FR, IT, ES, RU, TR, CN, & JP).DiagnosticsSmartLine transmitters all offer digitally accessible diagnostics which aid in providing advanced warning of possible failure events minimizing unplanned shutdowns, providing lower overall operational costs.Configuration ToolsIntegral Three Button Configuration OptionSuitable for all electrical and environmental requirements, SmartLine offer the ability to configure the transmitter and display via three externally accessible buttons when either display option is selected. Zero/span capabilities are also optionally available via these buttons with or withoutselection of a display option.Handheld ConfigurationSmartLine transmitters feature two-way communication and configuration capability between the operator and the transmitter. All Honeywell transmitters are designed andtested for compliance with the offered communication protocols and are designed to operate with any standards compliant handheld configuration device, such as the Honeywell Versatilis Configurator.Personal Computer ConfigurationOn a personal computer or laptop, Honeywell Field Device Manager (FDM) Software and FDM Express can be used for managing HART & Fieldbus device configurations.System Integration•SmartLine communications protocols all meet the most current published standards for HART/DE/Fieldbus.•Integration with Honeywell’s Experion PKS offers the following unique advantages.o Transmitter messaging.o Maintenance mode indication.o Tamper reporting.o FDM Plant Area Views with Health summaries.o All ST 800 units are Experion tested to providethe highest level of compatibility assurance.STA800 Smart Pressure Transmitter 3Modular DesignTo help contain maintenance & inventory costs, all ST 800 transmitters are modular in design supporting the user’s ability to replace meter bodies, add indicators or change electronic modules without affecting overall performance or approval body certifications. Each meter body is uniquely characterized to provide in-tolerance performance over a wide range of application variations in temperature and pressure and due to the Honeywell advanced interface, electronic modules may be swapped with any electronics module without losing in-tolerance performance characteristics.Modular Features•Meter body replacement•Exchange/replace electronics/comms modules*•Add or remove integral indicators*•Add or remove lightning protection (terminalconnection)** Field replaceable in all electrical environments (including IS) except flameproof without violating agency approvals.With no performance effects, Honeywell’s unique modularity results in lower inventory needs and lower overall operating costs. Plugged Impulse Line DetectionSTA800 models are offered with a PILD option which provides indication of a plugged impulse line or process connection. When used in conjunction with an advanced display, a non-critical diagnostic indication appears on the integral display. For units without an integral display, an indication can be seen via the host or handheld device when HART Protocol is utilized.Dual/Triple CalibrationSTA800 models are optionally offered with multiple calibrations. In lieu of a standard factory calibration, units can be supplied with 1, 2, or 3 customer specified calibrations. These calibrations are stored in the meter body and provide users with factory calibrated performance at up to three different calibrated ranges. This increases application flexibility without requiring any costly recalibration or additional inventory.4 STA800 Smart Pressure Transmitter Performance SpecificationsReference Accuracy:(conformance to +/-3 Sigma)Performance SpecificationsAccuracy at Specified Span and Temperature: (Combined Zero & Span, conformance to +/-3 Sigma)STA800 Smart Pressure Transmitter 5 Total Performance (% of Span):Total Performance Calculation: = +/- √(Accuracy)2 + (Temperature Effect)2Total Performance Examples (for comparison): standard accuracy 5:1 Turndown, +/-50o F (28o C) shiftTypical Calibration Frequency:Calibration verification is recommended every four (4) years.Notes:1. Terminal Based Accuracy - Includes combined effects of linearity, hysteresis, and repeatability. Analog output adds 0 .005% of span.2. For zero based spans and reference conditions of: 25o C (77o F), 10 to 55% RH, and 316 Stainless Steel barrier diaphragm.Operating Conditions – All ModelsLCD Display operating temperature -20︒C to +70︒C Storage temperature -30︒C to 80︒C.2Silicone 704 minimum temperature rating is 0o C (32o F). CTFE minimum temperature rating is -40︒C (-40︒F).3Short term equals 2 hours at 70︒C (158︒F)4 Units can withstand overpressure of 1.5 x MAWP without damage5Consult factory for MAWP of ST 700 transmitters with CRN approval6 STA800 Smart Pressure TransmitterFigure 2 - Measured pressure versus meter body temperature chart for STA722, 72LFigure 3 - Supply voltage and loop resistance chart & calculationsSTA800 Smart Pressure Transmitter 7 Performance Under Rated Conditions – All Models8 STA800 Smart Pressure Transmitter Materials Specifications(see model selection guide for availability/restrictions with various models)3 Monel® 400 or UNS N044004 Supplied as 316 SS or as Grade CF8M, the casting equivalent of 316 SS.5 Carbon Steel heads are zinc-plated and not recommended for water service due to hydrogen migration. For that service, use 316 stainless steel wettedProcess Heads.6 Hastelloy® C-276 or UNS N10276. Supplied as indicated or as Grade CW12MW, the casting equivalent of Hastelloy® C-2767 Monel® 400 or UNS N04400. Supplied as indicated or as Grade M30C, the casting equivalent of Monel® 400STA800 Smart Pressure Transmitter 9 Communications Protocols & DiagnosticsHART ProtocolVersion: HART 7Foundation Fieldbus (FF)* AI block may have two (2) additional instantiations.All available function blocks adhere to FOUNDATION Fieldbus standards. PID blocks support ideal & robust PID algorithms with full implementation of Auto-tuning.Link Active SchedulerTransmitters can perform as a backup Link ActiveScheduler and take over when the host is disconnected. Acting as a LAS, the device ensures scheduled data transfers typically used for the regular, cyclic transfer of control loop data between devices on the Fieldbus.Number of Devices/SegmentEntity IS model: 6 devices/segmentSchedule Entries18 maximum schedule entriesNumber of VCR’s: 24 maxCompliance Testing: Tested according to ITK 6.0.1 Software DownloadUtilizes Class-3 of the Common Software Download procedure as per FF-883 which allows the field devices of any manufacturer to receive software upgrades from any host. Honeywell Digitally Enhanced (DE)DE is a Honeywell proprietary protocol which provides digital communications between Honeywell DE enabled field devices and hosts.Standard DiagnosticsST 800 top level diagnostics are reported as either critical or non-critical and are readable via the DD/DTM/FDI tools or integral display. All critical diagnostics will appear on the Advanced and Standard integral displays, and some non-critical diagnostics will also appear on the Advanced integral display. Some of the diagnostics are listed below. Critical Diagnostics•Electronics Module Fault.•Meter body Memory Corruption.•Config Data Corruption.•Electronics Module Diagnostics Failure.•Meter body Critical Failure.•Sensor Communication Timeout.Non-Critical Diagnostics•Electronics Module Fault.•Display Failure.•Electronics Module Comm Failure.•Meter body Excess Correct.•Sensor Over Temperature.•Fixed Current Mode.•PV Out of Range.•No DAC Compensation.•Tamper Attempt Alarm.Refer to the product user manual for comprehensive list of diagnostics and details.Other Certification OptionsMaterialso NACE MRO175, MRO103, ISO1515610 STA800 Smart Pressure Transmitter Hazardous Areal CertificationsII 2 D Ex tb IIIC T95 Intrinsically Safe: SIRA 12ATEX2233XII 2 D Ex ia IIIC T125FISCO Field Device (Only for FF Option) Zone 2, Intrinsically Safe: SIRA12ATEX4234XFISCO Field Device (Only for FF Option) II 3 G Ex ic IIC T4 GcII 2 D Ex tb IIIC T95 Intrinsically Safe: CSAE 22UKEX1021XII 2 D Ex ia IIIC T125FISCO Field Device (Only for FF Option) Zone 2, Intrinsically Safe: CSAE22UKEX1008XFISCO Field Device (Only for FF Option) II 3 G Ex ic IIC T4 Gc1.Operating Parameters:Voltage = 11 to 42 VDC = 9 to 32 V (FF) Current = 4-20 mA Normal = 30 mA (FF)2.Intrinsically Safe Entity Parametersa. Analog/ DE/ HART Entity Values:Vmax = Ui = 30V Imax= Ii = 105mA Ci = 4.2nF Li = 984 uH Pi = 0.9WTransmitter with Terminal Block revision E or LaterVmax = Ui = 30V Imax= Ii = 225mA Ci = 4.2nF Li = 0 Pi = 0.9WNote : Transmitter with Terminal Block revision E or laterThe revision is on the label that is on the module. There will be two lines of text on the label:•First is the Module Part #: 50049839-001 or 50049839-002•Second line has the supplier information, along with the REVISION:XXXXXXX-EXXXX, THE “X” is production related, THE POSITION of the “E” IS THE REVISI ON.b. Foundation Fieldbus - Entity ValuesVmax= Ui = 30V Imax= Ii = 180mA Ci = 0nF Li = 984 uH Pi = 1WTransmitter with Terminal Block revision F or LaterVmax= Ui = 30V Imax= Ii= 225mA Ci = 0nF Li = 0 Pi = 1 WImax= Ii= 380 mA Ci = 0nF Li = 0 Pi = 5.32 W FISCO Field DeviceVmax= Ui = 17.5VNote : Transmitter with Terminal Block revision F or laterThe revision is on the label that is on the module. There will be two lines of text on the label:•First is the Module Part #: 50049839-003 or 50049839-004•Second line has the supplier information, along with the REVISION:XXXXXXX-EXXXX, THE “X” is production related, THE POSITION of the “E” IS THE REVISION.Approval CertificationsMounting & Dimensional DrawingsReference Dimensions:millimetersinchesMounting Configurations (Dual head design)Dimensions (Dual head design)Figure 4 – Typical mounting dimensions of STA822 & STA840 for referenceReference Dimensions:millimeters inchesMounting Configurations (Inline Designs)Dimension (Inline Design)Figure 5 – Typical mounting dimensions of STA82L, STA84L, & STA87L for referenceModel Selection GuideModel Selection Guides are subject to change and are inserted into the specifications as guidance only.Model STA800 & STA80LAbsolute Pressure TransmittersModel Selection Guide 34-ST-16-85, Issue 32Except Carbon Steel Heads shall use 316SS Vent/Drain & Plugs1aSTA822,840 supplied via 1/2" flange adapter same material as process head except carbon steel shall use 316 SS 1bReference head available only with Dual head models. In-line models supplied with process head only1cWhen selected for In-Line Gage models the Process Head / Bonnet is supplied in Dual Certified SS316/316LInstructions:Make selections from all Tables using column below the proper arrow. Asterisk indicates availability. Letter (a) refers to restrictions highlighted in the restrictions table. Tables delimited with dashes.List Price:Price equals the sum of prices for all selections made.3 NAMUR Output Limits 3.8 - 20.5mAdc can be configured by the customSTA800 Smart Pressure Transmitter211The PM option is available on all Smartline Pressure Transmitter process wetted parts such as process heads, flanges, bushings and vent plugs except plated carbon steel process heads and flanges. PM option information is also available on diaphragms except Gold plated and STG and STA in-line construction pressure transmitters.For more informationTo learn more about SmartLine Pressure Transmitters visit Or contact your Honeywell Account ManagerProcess Solutions Honeywell1250 W Sam Houston Pkwy S Houston, TX 77042Honeywell Control Systems LtdHoneywell House, Skimped Hill Lane Bracknell, England, RG12 1EB34-ST-03-85 October 2023©2023 Honeywell International Inc.Shanghai City Centre, 100 Jungi Road Shanghai, China 20061Sales and ServiceFor application assistance, current specifications, ordering, pricing, and name of the nearest Authorized Distributor, contact one of the offices below.ASIA PACIFICHoneywell Process Solutions, Phone: + 800 12026455 or +44 (0) 1202645583 (TAC) hfs-tac-*********************AustraliaHoneywell LimitedPhone: +(61) 7-3846 1255 FAX: +(61) 7-3840 6481 Toll Free 1300-36-39-36 Toll Free Fax: 1300-36-04-70China – PRC - Shanghai Honeywell China Inc.Phone: (86-21) 5257-4568 Fax: (86-21) 6237-2826SingaporeHoneywell Pte Ltd.Phone: +(65) 6580 3278 Fax: +(65) 6445-3033South KoreaHoneywell Korea Co Ltd Phone: +(822) 799 6114 Fax: +(822) 792 9015EMEAHoneywell Process Solutions, Phone: + 800 12026455 or +44 (0) 1202645583Email: (Sales)*************************** or (TAC)*****************************WebKnowledge Base search engine http://bit.ly/2N5VldiAMERICASHoneywell Process Solutions, Phone: (TAC) (800) 423-9883 or (215) 641-3610(Sales) 1-800-343-0228Email: (Sales)*************************** or (TAC)*****************************WebKnowledge Base search engine http://bit.ly/2N5VldiSpecifications are subject to change without notice.。

METTLER TOLEDO ACT350 ACT350xx POWERCELL 变送器用户手册说明

METTLER TOLEDO ACT350 ACT350xx POWERCELL 变送器用户手册说明

1.9. 配置工具...................................................................................................... 7
2 安装......................................................................................................8
30424736 | 03 | 12/2019
METTLER TOLEDO ACT350/ACT350xx POWERCELL 变送器用户手册
I
ACT350/ACT350xx POWERCELL 用户手册
3.5. 拨码开关和主复位 ..................................................................................... 19
2.4. 网络口连接 ................................................................................................ 16
2.5. 拨码开关.................................................................................................... 16
3 操作....................................................................................................17

1-氯丙烷气体报警传感器变送模块

1-氯丙烷气体报警传感器变送模块

1-氯丙烷气体检测传感器变送模块一,产品分类二,产品介绍单一气体1-氯丙烷气体检测传感器变送模块(网络版)简介大部分单一气体1-氯丙烷气体检测传感器输出信号都是非标准信号,不能直接使用,需要经过输出信号放大、滤波等处理等才可以使用。

安帕尔单一气体1-氯丙烷气体检测传感器变送模块(网络版),正是为了解决这些问题而研发的产品。

安帕尔科技是全球单一气体1-氯丙烷气体检测传感器变送模块(网络版)种类最齐全的公司,不论从量程选择、结构尺寸、供电方式、信号输出、功能特点等安帕尔科技基本上都有非常丰富的产品供您选择。

公司成立到现在一直都在为各行业、各环境的客户OEM和ODM各种各样的单一气体1-氯丙烷气体检测传感器变送模块(网络版)。

如您有特殊的单一气体1-氯丙烷气体检测传感器变送模块(网络版)需要开发,请咨询我公司。

多年的技术经验和强大的技术实力您放心的选择保障!无线1-氯丙烷气体检测传感器变送模块(网络版)简介安帕尔科技的无线1-氯丙烷气体检测传感器变送模块(网络版)具有无线输出方式多样,产品种类齐全的特点;WIFI、Zigbee、LO1-氯丙烷A、433M、800M、GP1-氯丙烷S/3G/4G等各种无线输出方式随意选择,可以满足市场上各种客户对无线现场使用的要求。

如您需要开发它其功能的无线1-氯丙烷气体检测传感器变送模块(网络版),请咨询安帕尔科技。

我们公司有多年的研发经验和强大的技术实力可以满足您的需求,请您放心的选择我们。

市面上大部分1-氯丙烷气体传感器输出信号都是非标准信号,不能直接使用,需要经过输出信号放大、滤波等处理等才可以使用,安帕尔无线1-氯丙烷气体检测传感器变送模块(网络版)正是为了解决这个问题而研发的产品。

三,产品特点单一气体1-氯丙烷气体检测传感器变送模块(网络版)特点★产品质量可靠、性能稳定:10多年的气体检测传感器变送模块研发经验,保证了安帕尔单一气体1-氯丙烷气体检测传感器变送模块(网络版)质量、性能的可靠性。

idp10差压变送器说明书

idp10差压变送器说明书

idp10差压变送器说明书
IDP10差压变送器是一种用于测量流体流动中压力差的仪器,通常用于工业控制和监测系统中。

它可以测量液体、气体或蒸汽等流体的压力差,从而确定流体流速或流量。

以下是IDP10差压变送器可能包含的一些说明书内容:
1. 产品描述,说明书会包括IDP10差压变送器的基本参数和特性,比如测量范围、精度等。

同时还会介绍其外观特征、安装方式等信息。

2. 技术规格,说明书中会详细列出IDP10差压变送器的技术参数,包括输入/输出信号范围、工作温度、工作压力、防护等级等,这些参数对于用户选择合适的设备和安装环境非常重要。

3. 安装和使用说明,这部分会详细描述IDP10差压变送器的安装方法、使用注意事项、维护保养等内容,以确保用户能正确安装和使用设备,并且能够保持其性能。

4. 现场校准,说明书可能会包括IDP10差压变送器的现场校准方法和步骤,以确保其测量准确性和稳定性。

5. 故障排除,针对常见问题,说明书通常也会提供故障排除的方法和建议,帮助用户在设备出现问题时能够及时解决。

6. 安全注意事项,最后,说明书还会包括一些安全注意事项,以及设备的环保要求等内容,帮助用户正确、安全地使用IDP10差压变送器。

总的来说,IDP10差压变送器的说明书将会全面介绍设备的技术参数、安装使用方法、维护保养、故障排除等内容,以帮助用户正确、安全地使用该设备。

希望这些信息能够对你有所帮助。

泛华测控压力和振动数据采集分析系统

泛华测控压力和振动数据采集分析系统
采 集 量 及 缩 短 了测 试 时 间 。该 系 统 采 用 便 携 式 设 计 , 对 数 据 可 进 行 时 域 频 域 分 析 , 生 成 报 表 。 中 P D谱 分 析 是 该 系 统 的 并 其 S 设 计 亮 点 之 一 , 是 目前 该 领 域 中 较 为 领 先 的 技 术 。 也
响度监测。
T -P DK E C推 出电网分析 用便携 式测量设备
T K E C推 出 爱 普 科 斯 研 制 的 完整 测 量 系 统 , 于 测 量 D —P 用 和 储 存 相 低 压 电 网 的 电 气 参 数 。MC 00 3设 计 用 于 测 量 70— 5 z 6 时 范 围 介 于 3X 0VA 0H 或 0Hz 3 C至 4 0VA ( — 和 4 C L N) 3 0VA 5 C至 6 0V A ( — ) 电 压 。 使 用 夹式 电 表 最 高 可 X 9 C L L 的 以记 录 30A电流 。除 了测 量 电压 、电流 和线 频 率之 外 , 00
21 0 0第 0 4期

MC 0 0 3还 用 于 测 量 70—
无 功 、 观 功 率 和 实 际 表
功率 ,以及功率 因数 ,
还 可 以 记 录 电 压 和 电
流谐 波 。 所 有 数 据 和 渎 数 都 以 数 字 或 图 形 形 式 显 示 在 像 素 为 2 4 8X6 的显 示 器 上 。 设 备 还 该
加速度等信号进行采 集 、 分析 以及存储 。 其秉 承了泛华测控一
贯 的 设 计 开 发 理 念 一 柔 性 测 试 技 术 ” 整个 系统 具 有 较 高 的 ” , 可 扩 展 性 ,最 多 可 配 置 达 8 单 轴 加 速 度 信 号 输 入 、 个 2个 轴

压力变送器协议种类

压力变送器协议种类

压力变送器协议种类
1. 4-20mA模拟信号协议,这是最常见的压力变送器输出信号协议之一。

在这种协议下,压力变送器将压力信号转换为4-20mA的模拟信号输出,通常用于远程传输和连接到PLC或DCS系统。

2. HART协议,HART(Highway Addressable Remote Transducer)协议是一种数字信号协议,它可以在4-20mA模拟信号的基础上叠加数字信号,实现对压力变送器的远程监测和配置。

HART协议的应用使得压力变送器可以实现智能化管理和诊断功能。

3. Foundation Fieldbus协议,Foundation Fieldbus是一种数字通信协议,它提供了更高级的数据传输和控制功能,适用于对实时性要求较高的工业自动化系统。

压力变送器采用Foundation Fieldbus协议可以实现更复杂的控制和监测功能。

4. Modbus协议,Modbus是一种常用的工业通信协议,适用于建立压力变送器与上位机或其他设备之间的通信连接。

通过Modbus 协议,压力变送器可以实现与其他设备的数据交换和控制。

除了上述列举的几种协议外,还有一些专有的通信协议和接口
标准,如Profibus、DeviceNet等,它们也被广泛应用于压力变送器的通信连接中。

选择合适的协议种类取决于具体的应用场景和系统要求,以确保压力变送器能够与其他设备有效地进行通信和数据交换。

浙大中控CJT型电容式智能压力变送器

浙大中控CJT型电容式智能压力变送器
非接液件材料
灌充液体:硅油。 螺栓和螺母:不锈钢。 电气壳体:低铜铝合金。 “O”形圈:丁腈橡胶。
引压管接口
法兰引压口:1/4-18NPT。
电气导线管接口
M20×1.5 两个接口。
外壳结构
IEC IP65 防护等级。
重量
约为 3.5kg(不包括选件)。
附件
连接块 (椭 圆法 兰): 可 将 导压管 接口 螺纹 转换为 1/2-14NPT,可选件。
明。
防爆结构
隔爆型:ExdⅡCT6。 本安型:ExiaⅡCT6。
量程和零点调整
可通过手持通讯器或变送器顶部的零点和量程按钮进 行调整;零位与量程可设定在量程范围内的任何值上。
正负迁移
零点可在各自量程段的极限范围内正负迁移。
阻尼
用手持通讯器进行调整,可设定在(0.1~16)s 之间。
报警
若变送器在自诊断时发现故障,则模拟量信号将输出高 报警(22mA)或低报警(3.8mA)电流以警告用户。
振动影响
在任意轴线上,S=0.15mm,频率为(10~55)Hz,引起 的误差为最大量程的±0.1%/g。
电源影响
小于输出量程的±0.05%/V。
负载影响
小于输出量程的±0.05%。
安装位置影响
最大可产生±0.24kPa 的零点误差,但可校正。
结构指标 接液件材料
隔离膜片:316L 不锈钢、哈氏合金 C。 排气/排液阀:316L 不锈钢。 法兰和接头:316L 不锈钢。 “O”形圈(与介质接触):氟橡胶。
输出
可选择线性或开方(4~20)mA 输出;叠加在(4~20)mA 信 号上的数字过程变量可提供给任何符合 HART 协议的主机。
电源

质量流量计使用说明书

质量流量计使用说明书
请确保在安装或检修仪表前切断电源
警告
不正确的安装可能使仪表不能正常工作或损坏
参考说明书的安装部分与传感器的接线部分
1.2传感器的结构与外形尺寸
1.2.1仪表参数
适用围:适用于液体、气体、液固、气固的微小质量流量的测量
测量管材质:304 或316L不锈钢
压力等级:标准配置见下表,其他高压可以特殊订货。
3.1.3测量单位的选择
选择不同单位后的量程转换是由软件自动完成的。
t/h kg/min L/minm3/h
3.1.4小数点位数的选择
可选择流量 0至3位小数显示
3.1.5电流输出的设置
可选择流量或者密度的(4—20)mA输出
3.1.6频率的输出
频率输出只对应“瞬时质量流量”或“相应质量流量”的体积流量。
2.1.2倒立安装
质量流量计测量气体(蒸汽)时建议安装方式,可以有效的排空仪表测量管可能存在的液体。
2.1.3旗式安装
悬浮液、液固两项流或某些特殊工艺场合的建议安装方式,比如:高温易凝固流体在生产结束时要求排空管道流体等。任何流体应用旗式安装不会影响流量计的测量精度,但流体方向必须自下而上。
2.1.4其它安装要求
型号
仪表通径
测量围(Kg/h)
工作压力(MPa)
连接形式(mm)
-1-A
3
4~40
0~32
焊接式活接头 Φ6×1.5
-1-B
6
10~100
0~25
焊接式活接头 Φ10×2
-2-A
8
20~200
0~20
焊接史活接头 Φ12×2
-2-B
10
40~400
0~25
焊接式活接头 Φ14×2
  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

安费诺先进传感器推出IPT2000压力变送器
 安费诺先进传感器推出一款IPT2000压力变送器,防护等级IP67,拥有优异的EMC性能,采用多种电气连接方式,可应用于工业过程控制、供热、HVAC控制、空压机、注塑机、工程机械、水处理、船舶、锅炉等领域。

 安费诺先进传感器IPT2000压力变送器过载能力强,为满量程的6到10倍,拥有高灵敏度的输出功能同时微功耗;先进的数字补偿及放大工艺使产品具有更高的精度及低的温度系数;电子兼容设计使得抗干扰能力强,可以适用在各种恶劣环境。

 作为安费诺授权分销商,Heilind可为市场提供相关服务与支持,此外Heilind也供应多家世界顶级制造商的产品,涵盖25种不同元器件类别,并重视所有的细分市场和所有的顾客,不断寻求广泛的产品供应来覆盖所有市场。