SD5075 两线通信数字温度传感器规格书v1.1b
温度传感器传输器(DIN 尺寸)说明书

iiE -'%: GYJ17.1057X(�±t: Obere Wank 1, 87484 Nesselwang, Germany)� � jE!Jlt3t:�$ (�$h.��)� -'% � � TMT121/127/128 -*�tllJf.i 11 *� � Ex nA II C T4-T6 Ge00 *$ UQ -'% 141000000GB 3836.1-2010, GB 3836.8-2014� ftVi � llt iiE 0* iiE � fi $& Wh 2017 � 2 .Fl 22 f3 � 2022 � 2 .Fl 21 B� 51 1. ��f�m 51��I»im*iiE� 1l11i!fo2. iiE�t.Ifij-%J§g� "x" �a,ijf"�1t���1�m���i!f, r*.J�m*iiE�1l11i!fo3. m-%m�iJta,ijm*iiE�1l11i!fo4. It ����J&m*iiE�1l11i!fo5. *iiE�li5'Jlt1�mT.'�l�wr�wr;li�,}tf)(.* (�#I) ��lH}i'iJ (�±t: �#lI�Il!I!R�!l!Ia:p�465-%) �f"l't.Jli5'Jm-%f"�o:tt!!.il: : ..t. jfiHP' m 3i: R& 103�JIlß!.IiQ: 200233 1XX.I!.il:: www.nepsLo r Emai l:****************��: +8621 643681801{,Ji: +8621 64844580EXPLOSION PROTECTIONCERTIFICATE OF CONFORMITYCert NO.GY J17.1057XThis is to certify that the productTemperatllre transmitter (DIN raH)manufactured by Endress + Hauser Wetzer GmbH + Co. KG(Address:Obere Wank 1,87484 Nesselwang, Gerrnany)which model is TMT1211127/128 SeriesEx marking Ex nAlIC T4�T6 Geproduct standard /drawing number 14 1000000has been inspected and certified by NEPSI, end that it conformsto GB 3836.1-2010,GB 3836.8-2014This Approval shall remain in force until 2022.02.21Remarks I.Conditions for safe use are specified in the attachment(s) to this certificate.2.Symbol "X" placed after the certification number denotes specific conditions of use,which are specified in the attachment(s) to this certificate.3.Model designation is specified in the attachment(s) to this certificate.4.Safe parameters specified in the attachment(s) to this certificate.5.This certificate is also applicable for the product with the same type manufactured byEndress+Hauser Wetzer (Suzhou) Co., Ltd. (address: Su Hong Zhong Lu No.465,S u z hou-S I P, China)DirectorThis Certificate is valid for products com patible with the d ocuments and sam p ies alJproved by NEPSI.103 Cao Bao Road Shanghai 200233, China Email:**************.cnTel: +862164368180Fax: +8621 64844580Editlon05�*�tt�tt��.*�����M National Supervision and Inspection Centre forExplosion Protection and Safety of Instrumentation (GYJ17.1057X) (Attachment I )GY J17.1 057X�lIit�iiEffi"{tt I1'1'1 }ßl1i&\;ltfr+ ;;:Wri� '§'j �tz: ß'.JTMT121/127/128�3i�1Mdt5V!:1l� c ��j L:t:�) , � I� �� 1x..g�1x�Il1J��:i:%-l.'����ft�(NEPSIH:ft��, �B:ifTJ�f5Ff1t:GB3836.1-2010 ;l�HFtl:l:;f:LJ't�1:gf)7J\.: &-1.r J.ill.):g�*GB3836.8-2014 ;/;!!Ht'l"tPfm �8:gß7t: U,I "n"FJD�J5il�HF;:tEx nA II C T4�T6 Ge, �J5;tiif*hLE�GY J17.1 057Xo;;$: iLE.=p; iA PT I'('.J F���. #Ht P�I T :iTEMP pCP DIN rail TMT 121-20iTEMP RTD DIN rail TMT 127-20iTEMP TC DIN rail TMT 128-20X�: O*��.��.��� .•• ffi��, W�F��mm��o-. F 5it:tc:i:�ffl *f��{tfA#�W�T:;;$:F�10f�*�fi;J, :tIJJUh1tmn�·�N:t:�fr�B:�GB4208-2008N\lJEFI J IP54�Lt. JitittJ"J!: GB3836.1-201 o tnGB3836.8-2014!?f*ß'.Jjr:J't/!=' 0=,F5it�fflr±f!.J.}Ji1, FRn1!fmJf:Ijß�ffiU�t D�JJnBjJiJB���:�l5tmfJl J T4 T5 T6jb9=:q��11ü\.15t -40'C-+85'C -40'C -+65 'c -40'C-+50'C2. FRr,I'F11jt Ft!, Itlli15J: 8�35Vde o3. 7t� B� fm!t l}[ 5e�..g� j r :rMfr�}1±fuftltd T, IJI)h 1!f m n�' @04.m����ff�.���F�ß'.J��$$#, @��F���ft��M*�ff�� ���., ����m.tl��m���ß'.J��o5. F� 1'F1:t:�. 1!ft8tD�fu�)� @If.1J F,f�r1!f Fl-J���. GB3836.13-2013 "!it1=tt:q� lJ't �13gß7t:&�B�1Itll. fft11t. 1��tDi:&jjl[" GB3836.15-2000 ".tt:'t1/-"t#Pf l�t8� �1Jl� t1115$7t: m:;�ft:f:hfifi��:t:� ctNJrI!#;jl') " GB3836.16-2006 ".tH1�1*Pfjjt ffllt�i&1k-�16tfll5}: t:h���ß'.J��t D�tt�J� o}.lnr�#;!tr) " RGB50257-2014 "�I1�i&.�(GY J 17.1 057X)�,it!J)t rJJf iE2mU � r &, �JjJ )'L I<: *it :r5< fln NE P SI iA riJ-B� )( 1�: j9i �4 �F ; 3 � � tt Jt� rp ßY � j> {Q. J5 r JU r*J � :a) N EPS I -!A nJt;F$ (�ltIJ;lIil-*itiiE b) c )�)]-;lI il-*it iiE -'%d ) 1t J-FJ Jf jjHfm &(Attachment I )�*�{)(�{)(��1I��lI{r1f�%M National Supervision and Inspection Centre forExplosion Protection and Safety of Instrumentation(GYJ17.1057X) (Attachment I )Attachment I to GYJ17.1057X1.TMT121 /127/128 series Temperature transmitter (DIN rail), manufactured by Endress+Hauser Wetzer GmbH + CO.KG, has been certified by National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation (NEPSI). The product accords with following standards:G83836.1-2010 Explosive atmospheres-Part 1: Equipment-General requirementsG83836.8-2014 Explosive atmospheres-Part 8: Equipment protection by type of protection "n"The Ex marking is Ex nA TI C T 4-T6 Gc, its certificate number is GY J17.1 057X.Type approved in this certificate is shown as the following:iTEMP PCP DIN rail TMT121-2DiTEMP RTD DIN rail TMT127-2DiTEMP TC DIN rail TMT128-2Do indicates type of connection, sensor, meauring range and ete.Refer to instruction manual for the details.2. Special Conditions for Safe UseThe suffix "X" placed after the certificate number indicates that this product is subject to special conditions for safe use, that is:When using this head type product, it shall be installed in the enclosure which IP degree is at least IP54 according to G84208-2008, and meet the relative requirements of G83836.1-201 0 and G83836.8-2014.3. Conditions for Safe Use3.1 The relationship between ambient temperature range and the temperature class is shown as folIows:Temperature class T4 T5 T6Ambient temperature range -40"C-+85"C -40"C-+65"C -40"C-+50"C3.2 Electrical data: 8-35 Vdc.3.3 The external earth connection facility of the whole product shall be connected reliably.3.4 The user shall not change the configuration in order to maintain/ensure the explosion protection performance of the equipment. Any change may impair safety.3.5 For installation, use and maintenance of this product, the end user shall observe the instruction manual and the following standards:Page 1 of 2(GY J17.1 057X) (Attachment I )GB50257-2014 "Code for construction and acceptance of electric device for explosion atmospheres and fire hazard electrical equipment installation engineering".GB3836.13-2013 "Explosive atmospheres-Part 13:Equipment repair, overhaul and reclamation".G B3836.15-2000 "Electrical apparatus for explosive gas atmospheres-Part 15:Electrical installations inhazardous area (other than mines)".GB3836.16-2006 "Electrical apparatus for explosive gas atmospheres-Part 16:lnspection and maintenance of electrical installation (other than mines)".4. Manufacturer's Responsibility4.1 Conditions for safe use, as specified above, should be included in the documentation the user is provided with. 4.2 Manufacturing should be done according to the documentation approved by NEPSI.4.3 Nameplate should include these contents listed below:1) NEPSl logo @2) Ex marking3) certificate number4) ambient temperature5) electrical dataPage 2 01 2。
510系列说明书最终版

二、技术参数
输入
输入信号 输入阻抗 输入电流
电流 ≤250Ω ≤30mA
电压 ≥500KΩ
电阻
最大限制
输入电压 最大限制
≤6V
输出
输出信号
电流
电压
继电器
输出负载能力 ≤500Ω
≥250 KΩ (注:需要更高负载
能力时须更换模块)
AC220V/0.6(小) DC24V/0.6A(小) AC220V/3A(大)
★ 返回工作状态 1 手动返回:在仪表参数设定模式下,按压 键4秒后,仪表即自动回到实时测量状态。 2 自动返回:在仪表参数设定模式下,不按任何按键,30秒后,仪表将自动回到实时测量状态。 六、参数设置
6.1一级参数设置
在工作状态下,按压 键PV显示LOC,SV显示参数数值:按 或 键来进行设置,长按 键2秒可返回上 一级参数,Loc等于任意参数可进入一级参数
五、通电设置 仪表接通电源后,即进入自检状态(见右图),自检完毕后,仪表自动转入工作状态, 在工作状态下,按压 键显示LOC,LOC参数设置有如下: 1、1) Loc等于任意参数可进入一级菜单(LOC=00;132时无禁锁);
2) Loc=132,按压 键4秒可进入二级菜单; 3) Loc=130,按压 键4秒可进入时间设置菜单;对于带打印功能的表. 4) Loc等于其他值,按压 键4秒退出到测量画面。 2、如果Loc=577,在Loc菜单下,同时按住 键和 键达4秒,可以将仪表的 所有参数恢复到出厂默认设置。 3、在其它任何菜单下,按压 键4秒即可退出到测量画面。 4、在测量画面下同时按压 键和 键4秒,可修改一级参数的报警值。 5、采用热电偶信号输入时,通道小数点dP=0时,温度显示分辨率为1℃;dP=1 时,温度显示分辨率为0.1℃,(1000℃以上自动转为1℃分辨率)。 6、时间设定 在仪表PV显示测量值的状态下,按压 键进入参数,设定LOC=130,在PV显示LOC,SV显示130的状态下,按压 键4秒,即进入时间参数设定,仪表PV显示"dATE",SV显示当前日期(如:100120-2010年1月20日),在此状态下 ,可参照仪表参数设定方法,设定当前日期。在仪表当前日期显示状态下,按压 键,仪表PV显示"TlnE",仪表 SV将显示当前时间(如183047 -18点30分47秒),在此状态下,可参照仪表参数设定方法,设定当前时间。在仪 表当前时间显示状态下,再次按压 键,则退出时间设定,回至PV测量值显示状态。
温湿度传感器(型号:WHT20B)使用说明书

温湿度传感器(型号:WHT20B)使用说明书版本号:1.0实施日期:2023-02-01郑州炜盛电子科技有限公司Zhengzhou Winsen Electronic Technology Co.,Ltd声明本说明书版权属郑州炜盛电子科技有限公司(以下称本公司)所有,未经书面许可,本说明书任何部分不得复制、翻译、存储于数据库或检索系统内,也不可以电子、翻拍、录音等任何手段进行传播。
感谢您使用本公司的系列产品。
为使您更好地使用本公司产品,减少因使用不当造成的产品故障,使用前请务必仔细阅读本说明书并按照所建议的使用方法进行使用。
如果您没有依照本说明书使用或擅自去除、拆解、更换传感器内部组件,本公司不承担由此造成的任何损失。
您所购买产品的颜色、款式及尺寸以实物为准。
本公司秉承科技进步的理念,不断致力于产品改进和技术创新。
因此,本公司保留任何产品改进而不预先通知的权力。
使用本说明书时,请确认其属于有效版本。
同时,本公司鼓励使用者根据其使用情况,探讨本产品更优化的使用方法。
请妥善保管本说明书,以便在您日后需要时能及时查阅并获得帮助。
郑州炜盛电子科技有限公司WHT20B温湿度传感器产品描述WHT20B温湿度传感器嵌入了适于回流焊的双列扁平无引脚SMD封装,温度和湿度信号可以在不同的引脚读出,底面3.0×3.0mm,高度1.0mm。
传感器输出经过标定的数字信号,标准I2C格式。
WHT20B温湿度传感器,包含一个全新设计的ASIC专用芯片内置晶体管Vbe温度特性,实现高精度温度检测;同时包含一个电容湿度芯片,其中湿敏材料吸湿后介电常数变化实现环境湿度检测。
并结合最新的集成电路信号处理技术而成的双芯片解决方案。
具有体积小、功耗低、可靠性高、兼容性好等优点。
产品特点⏹高精度,±3.0%RH和±0.5℃⏹宽电源电压范围,从2.0V到5.5V⏹采用SMD封装,适于回流焊⏹响应迅速、抗干扰能力强⏹高湿条件下优异的长期稳定性应用场景家电领域:家电、湿度调节、暖通空调、除湿机、智能恒温器、房间监视器;工业领域:汽车、测试及检测设备、自动控制;其他领域:数据记录器、气象站、医疗及其他相关温湿度检测控制。
SD5075 两线通信数字温度传感器规格书v1.1b

单次测温模式
芯片的单次测温模式通过设置配置寄存器 的 bit5 来实现。当 bit5 设置为“1”时,芯片 立刻进入待机状态,此时芯片功耗小于 1uA。
向地址指针寄存器写 04H,然后(向单次 测温寄存器,见图 5)写任意 8 位值启动一次温
该温度寄存器的高字节为温度的整数部 分,低字节的高 4 位为温度的小数部分,因此 分辨率为 0.0625℃。如果测量温度结果超出 -55℃ ~ +125℃范围,则可能会超出最大误差。 如果分辨率 1℃就可以满足用户要求,可以只 使用温度寄存器的高 8 位。
表 2. 温度测量结果
温度
温度测量结果(二进制)
属性
管脚描述
数字输入/输出
两线通信数据线
数字输入
两线通信时钟线
输出
开漏端口,作温度报警或者 SMBus Alert 用
地
地
数字输入
地址选择信号
电源
电源
功能描述
VDD 8 GND 4
A0 7 A1 6 A2 5 SCL 2 SDA 1
寄存器: 地址指针 温度结果
配置 迟滞阈值 过温阈值 单次测温
2线通信 接口 和
控制器
ALARM 3
过温检测
参考电压 温度传感器
温度校准
Sigma-Delta 模数转换器
RC振荡器
图 2. 功能框图
图 2 是 SD5075 的功能框图。SD5075 是一 个 2 线通信的数字温度传感器,芯片内部的温 度传感器产生一个跟温度成正比变化的电压信 号,再经过自带电压基准的 ADC 转换成数字 信号,保存为 12 位二进制补码形式,以便表示 正温度或者负温度。
MTL5074温度传感器转换器说明书

EUROPE (EMEA) Tel: +44 (0)1582 723633 Fax: +44 (0)1582 422283AMERICAS Tel: +1 281 571 8065 Fax: +1 281 571 8069ASIA PACIFIC Tel: +65 6 487 7887 Fax: +65 6 487 7997E-mail:***************************:Aug 2008The MTL5074 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safe-area load. Software selectable features include linearisation, ranging, monitoring, testing and tagging for eight thermocouple types and 2-, 3- or 4-wire RTDs. For thermocouples requiring cold-junction compensation, the HAZ-CJC plug can be ordered with the product, and includes an integral CJC sensor.SPECIFICATION See also common specification Number of channels One Signal source Types J, K, T, E, R, S, B or N THCs to BS 4937EMF input 2/3/4-wire platinum RTDs to BS 1904/DIN43760 (100Ω at 0°C) Location of signal source Zone 0, IIC, T4 hazardous area Div.1, Group A, hazardous location Input signal range –75 to +75mV, or 0 to 400Ω (Input impedance 10M Ω)Input signal span 3 to 150mV, or 10 to 400ΩRTD excitation current 200µA nominal Cold junction compensation Automatic or selectable Cold junction compensation error≤1.0°C Common mode rejection 120dB for 240V at 50Hz or 60Hz Series mode rejection 40dB for 50Hz or 60Hz Calibration accuracy (at 20°C)(includes hysteresis, non-linearity and repeatability) Inputs:m V/THC: ±15µV or ±0.05% of input value (whichever is greater) R TD: ±80m ΩOutput: ±11µA Temperature drift (typical) Inputs:m V/THC: ±0.003% of input value/°C R TD: ±7m Ω/°C O utput: ±0.6µA/°C Example of calibration accuracy and temperature drift (RTD input)Span: 250ΩAccuracy: ± (0.08/250 + 11/16000) x 100% =0.1% of span Temperature drift: ± (0.007/250 x 16000 + 0.6) µA/°C = ±1.0µA/°C Safety drive on sensor burnout U pscale, downscale, or off Output range 4 to 20mA nominal (direct or reverse)Maximum load resistance 600ΩLED indicator G reen: one provided for power and status indication Power requirement, Vs with 20mA signal 68mA at 24V 82mA at 20V 52mA at 35V Power dissipation within unit with 20mA signal 1.5W at 24V 1.6W at 35V MTL5074 TEMPERATURE CONVERTER THC or RTD input Isolation 250V ac between safe- and hazardous-area circuits and power supply Safety description Terminals 1 and 3i) Without CJ plug V out = 1.1V I out = 7mA P out = 2mW Non-energy-storing apparatus ≤1.2V, ≤0.1A, ≤20µJ and ≤25mW. Can be connected without further certification into any IS loop with open-circuit voltage not more than 10V.ii) With CJ plug V out = 6.6V, I out = 10mA P out = 17mW Terminals 1 and 3, 4 and 5V out = 6.6V, I out = 76mA, P out = 0.13W Configuration socket (CON6)V out = 8.3V, I out = 15mA, P out = 26mW Standard configuration Input type RTD, 3-wire Linearisation enabled CJ Compensation disabled Units °C Damping/Smoothing value 0 seconds/0 seconds Output zero 0°C Output span 250°C Tag and description fields blank Open circuit alarm set high (upscale)Transmitter failure alarm set low (downscale)CJ failure alarm set low (downscale)Line frequency 50Hz Configurator A personal computer running MTL PCS45 software with a PCL45 interface.TO ORDER, specify:MTL5074 Includes HAZ-CJC signal plug (with internal CJC sensor). For use with thermocouple, mV or RTD inputs.MTL5074-RTD Includes standard HAZ1-3 signal plug. For use with mV or RTD inputs. (Can be used with thermocouples with cold-junction compensation if HAZ-CJC plug is fitted.)HAZ-CJC Hazardous-area signal plug for terminals 1 to 3 including cold-junction compensation sensor.TerminalFunction 1 THC/EMF/RTD input –ve 3 THC/EMF/RTD input +ve 4 3-wire RTD input –ve 5 4-wire RTD input +ve 11 Output –ve 12 Output +ve 13 Supply –ve 14 Supply +ve Jan 2012。
温度传感器说明书.

SWD系列温度传感器用户使用说明书北京传感星空自控技术有限公司SWD 系列温度传感器使用说明书SWD 系列温度传感器是用铂金属丝制成的测温度电阻器,可用来测量各种液体、气体等流体的温度。
具有精度高、分辨率好,安全可靠、使用方便等优点,也可以直接测量各种生产过程中的液体、蒸气和气体介质的温度。
一、原理本传感器是利用铂金属(PT100)在温度变化时自身电阻也随着变化的特性来测量温度的。
它的受热元件是利用细铂丝均匀的双绕在绝缘材料制成的骨架上。
二、技术指标1、0℃对应电阻为100Ω,100℃对应电阻为138.5Ω2、测量范围:-200~500℃3、时间参数:<5秒4、外型尺寸:参照定货要求三、传感器接线示意图四、安装使用方法及注意事项1、本温度传感器通过螺纹固定。
在固定的时候切记不要用力过度,以免损坏传感器。
2、如传感器有杂质粘附于传感器上,要及时清洗,保证传感器可靠、准确运行。
3、线缆的铺设以不防碍现场工作人员的现场操作和不易被砸碰、损坏且架设安全可靠为原则。
三线制四线制4、传感器接触的介质应为经常流动的介质,这样才能保证所测值的准确性。
五、故障现象及现场处理办法1、如果温度传感器在使用过程中发生故障,如无信号输出或超过标准输出,首先应检查线缆的断线、短路及接线的脱落。
2、怀疑温度传感器有故障,可用万用表测量铂电阻的电阻值是否在正常范围之内。
如铂电阻的输入正常,则应检查上位仪表。
3、本传感器出厂时已作密封处理,如出现故障,请送厂里维修,用户不要自行拆卸。
4、本传感器自出售之日起。
一年内出现故障,可免费维修或更换,终身维修。
久茂自动化(大连)有限公司 室内、室外、通道温度测量热电阻说明书

室内、室外、通道温度测量热电阻⏹测温范围-50~+90℃(200℃)⏹用于空调行业⏹防护等级从IP20到IP65⏹二线制、三线制或四线制连接⏹可提供变送器一体化型(4~20mA或0~10V)该电阻温度计主要应用于空调系统,用来测量室温、通风孔及室外的温度。
采用不同的塑料外壳以满足各种特殊应用所要求的不同防护等级。
传感器通常使用一支符合DIN EN 60751 B级二线制的Pt100热电阻,也可提供Pt500、Pt1000、Ni1000型和各种NTC版本。
从接线盒开始可进行三线或四线连接,可提供变送器一体化型。
技术数据接线盒塑料PC支架(材料PP对应型号902520/11),防护等级从IP20到IP65 型号902524/25防护等级IP54和IP65保护管不锈钢1.4571,直径6mm热电阻插芯Pt100热电阻温度传感器,DIN EN 60751 B级,二线制Pt1000热电阻温度传感器,DIN EN 60751 B级,二线制更多热电阻温度传感器请参考选型说明变送器模拟变送器,输出4~20mA或0~10V变送器1所指数据为量程满度20mA2使用较高数据认证/认证标准接线图标准版本变送器用于基本型号902520/10变送器适用于基本型号902520/2x和902524/3x供电单元接线示例,4~20mA和0~10V外形尺寸基本型号 902520/10基本型号 902520/11基本型号 902520/15基本型号 902520/21基本型号 902520/22基本型号902520/23基本型号 902520/24基本型号 902524/25基本型号 902524/31基本型号 902524/32选型说明:室内、室外、通道温度测量热电阻(1)基本型号(1)(2)(3)(4)(5)选型代码- - / (1)选型举例902520/10 - 572 - 1001 - 1 / 0001请逐一列出附加代码,代码顺序由小到大,用逗号隔开2请指明测量范围选型说明:室内、室外、通道温度测量热电阻(1)基本型号×658(1)(2)(3)(4)(5)选型代码- - /选型举例902520/21 - 573 - 1003 - 1 / 000选型说明:室内、室外、通道温度测量热电阻(1)基本型号(1)(2)(3)(4)(5)(6)(7)(8)选型代码- - - - - - / (1)选型举例902524/25 - 380 - 1003 - 1 - 6 - 100 - 000 / 0001请逐一列出附加代码,代码顺序由小到大,用逗号隔开2工艺连接可在“工艺连接附件”部分找到选型说明:室内、室外、通道温度测量热电阻(1)基本型号(1)(2)(3)(4)(5)(6)(7)(8)- - - - - / (1)902524/31 - 380 - 1003 - 1 - 6 - 100 - 000 / 0001请逐一列出附加代码,代码顺序由小到大,用逗号隔开2请指明测量范围过程连接附件。
SD5075简记_Summary

SD5075数字温度传感器 Digital Temperature Sensor主要特点●12位数字温度读数,分辨率为0.0625℃。
● 在-40℃~+100℃范围内最大误差±0.8℃。
● 在-55℃~+125℃范围内最大误差为±1.5℃。
● 2线通信接口,跟I 2C/SMBUS 协议兼容。
● 提供过温报警功能,可设置过温阈值及迟滞恢复阈值。
● 可选连续测温模式或单次测温模式。
● 连续测温时典型工作电流只有170uA ,关断模式工作电流小于1uA 。
● 工作电压范围:2.7V ~5.5V 。
● 管脚兼容ADT75/LM75A/TMP75。
Features●12 bits digital temperature readout, 0.0625℃ resolution ● ±0.8℃ maximum error at -40℃~+100℃ range ● ±1.5℃ maximum error at -55℃~+125℃ range ●Two wires communication interface, compatible with I 2C/SMBus protocol●Over-temperature alarm function, user settable alarm threshold and hysteresis● Continuous or single measurement options ●170uA typical during measurement, less than 1uA at shutdown mode● 2.7V ~ 5.5V power supply range●Pin compatible with ADT75/LM75A/TMP75Fig1. 典型应用图(Typical application diagram )经大量测试数据总结,SD5075测温误差低于同类型管脚兼容的产品。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
0000H 00H 4B00H (75℃) 5000H (80℃) XXH
地址指针寄存器: 8 位地址指针寄存器用于设置要读或者写
的寄存器地址。该寄存器只能写,不能读。上 电后的值默认为 00H。
温度结果寄存器(00H): 16 位温度结果寄存器用于存储芯片上温
芯片内有过温阈值寄存器和迟滞阈值寄存 器,测温值会与这些寄存器值作比较,决定是 否通过开漏结构的报警输出端口(ALARM)输 出报警信号。该报警信号的极性可在配置寄存 器中预设选择。
温度值的读出以及寄存器的设置均通过一 个 2 线通信接口,兼容 I2C/SMBus 通信协议。 片内 RC 振荡器提供系统时钟,完成一次温度 测量的时间约为 85ms。测温过程中 ADC、电 压基准、时钟等电路都工作,系统功耗最大。
如果 SDA 管脚拉低的时间维持 200ms 以 上,SD5075 的两线接口会复位到空闲(开漏) 状态,等待启动条件。
在一次操作中可以完成多个字节数据的读 或者写,但不能在一次操作中既读又写。
写数据
写数据过程有两种:一种是为了读某个寄 存器的值,需要先对地址指针寄存器写该寄存 器的地址,见图 4;另外一种是向某个寄存器 写数据,见图 5 和图 6。图 5 是向 8 位寄存器 写数据,图 6 是向 16 位寄存器写数据,第三帧 数据后需要再多写入一个字节数据。
比较模式 高电平有效 中断模式 高电平有效
ALARM ALARM
读
过温 阈值
迟滞 阈值
时间
读
读
图 3. ALARM 温度响应输出
寄存器说明
SD5075 有六个寄存器:一个 8 位地址指 针寄存器、四个数据寄存器(16 位温度结果寄 存器、8 位配置寄存器、16 位迟滞阈值寄存器、 16 位过温阈值寄存器)、一个 8 位单次测温寄 存器。,具体见表 3。
SD5075
两线通信数字温度传感器
特点
12 位数字温度读数,分辨率为 0.0625℃ 在-40℃ ~ +100℃范围内最大误差±0.8℃ 在-55℃ ~ +125℃范围内最大误差±1.5℃
2
2 线通信接口,兼容 I C/SMBus 协议 提供过温报警功能,可设置阈值及迟滞量 可选“连续测温模式”或“单次测温模式” 低功耗:测温时典型工作电流只有 170uA,
从机 主机发送 应答 停止信号
图 4. 写入地址指针寄存器以选择用于随后续操作的寄存器
版本 v1.1b 2017/01 tel:13713800286
第5页共5页
SD5075
1 SCL
9
1
9
SDA
1
主机发送 启动信号
Bit6:保留
Bit5:为“1”时,芯片进入单次测温工作 模式,写“1”后芯片立即进入待机状态。为“0” 时,芯片进入连续测温工作模式。
Bit4-3:选择过温事件发生次数(N),防 止误判过温。只有过温事件连续发生 N 次后才 确认过温,具体关系见表 5。
表 5. Bit4-3 与过温次数关系
bit4-3
SD5075 有一个 7 位的从机地址,高 4 位 固定为 1001,低 3 位地址取决于管脚 A2-A0 的设置。表 6 是该芯片可以设置的地址。
表 6. A2-A0 设置和地址关系
A2-A0
地址
000
48H
001
49H
010
4AH
011
4BH
100
4CH
101
4DH
110
4EH
111
4FH
SD5075
过温次数(N)
00
1
01
2
10
4
11
6
Bit2: 定义 ALARM 管脚输出极性。“1” 事件发生时,输出高电平;“0”事件发生时, 输出低电平。
Bit1:定义过温的输出模式。“1”为中断 模式;“0”为比较模式。
Bit0:关断模式,设定“1”时,芯片进入 关断模式,启动单次测温命令无效,工作电流 小于 1uA。两线通信接口可以工作,其他电路 关闭。
迟滞阈值寄存器(02H): 16 位寄存器,低 4 位无效,可以读/写,
用于设置过温报警恢复的下限温度,默认设置 是 75℃。数据格式是补码形式,最高位是符号 位:“0”表示正温度;“1”表示负温度。
过温阈值寄存器(03H): 16 位寄存器,低 4 位无效,可以读/写,
用于设置报警值的上限,默认设置是 80℃。数 据格式是补码形式,最高位是符号位:“0”表 示正温度;“1”表示负温度。b 2017/01 tel:13713800286
第4页共4页
两线通信口
SD5075 有一个两线通信接口,协议兼容 I2C/SMBus,作为一个从机,可以通过这个接 口接受外部的控制,亦可以通过 Alert 功能向 主机发出服务请求。图 10 为 SD5075 的一种单 从机典型应用,ALARM 管脚、SDA 和 SCL 管脚都各需要一个上拉电阻。
关断模式工作电流小于 1uA 工作电压范围:2.7V ~ 5.5V 管脚兼容 ADT75/LM75A/TMP75
典型误差小于±0.5℃,在-55℃ ~ +125℃范围
2
内典型误差小于±1.0℃。通过两线 I C/SMBus 接口可以很方便与其他设备建立通信。设置 A2 ~ A0 的地址线,可支持 8 片芯片并联总线连接。
如果写入的字节数超出了寄存器的字节 数,多余的字节会被自动忽略。如果要写不同 地址的寄存器,需要重新发起一个写数据过程。
1
91
9
SCL
SDA
1 0 0 1 A2 A1 A0 R/W
P7 P6 P5 P4 P3 P2 P1 P0
主机发送 启动信号
第一帧数据,发送 从机地址
从机(SD5075) 应答
第二帧数据,向地址指针寄存 器写入要读的寄存器地址
属性
管脚描述
数字输入/输出
两线通信数据线
数字输入
两线通信时钟线
输出
开漏端口,作温度报警或者 SMBus Alert 用
地
地
数字输入
地址选择信号
电源
电源
功能描述
VDD 8 GND 4
A0 7 A1 6 A2 5 SCL 2 SDA 1
寄存器: 地址指针 温度结果
配置 迟滞阈值 过温阈值 单次测温
2线通信 接口 和
该温度寄存器的高字节为温度的整数部 分,低字节的高 4 位为温度的小数部分,因此 分辨率为 0.0625℃。如果测量温度结果超出 -55℃ ~ +125℃范围,则可能会超出最大误差。 如果分辨率 1℃就可以满足用户要求,可以只 使用温度寄存器的高 8 位。
表 2. 温度测量结果
温度
温度测量结果(二进制)
中断模式:当测量温度值高于过温阈值寄 存器或者低于迟滞阈值寄存器时,ALARM 输 出有效电平;当读 SD5075 的任意寄存器时, ALARM 管脚输出默认电平。
温度 82℃ 81℃ 80℃ 79℃ 78℃ 77℃ 76℃ 75℃ 74℃ 73℃
比较模式 低电平有效
中断模式 低电平有效
ALARM ALARM
对于 12 位温度测量结果: 正温度值=温度测量结果/16 负温度值=(温度测量结果-4096)/16
单次测温模式
芯片的单次测温模式通过设置配置寄存器 的 bit5 来实现。当 bit5 设置为“1”时,芯片 立刻进入待机状态,此时芯片功耗小于 1uA。
向地址指针寄存器写 04H,然后(向单次 测温寄存器,见图 5)写任意 8 位值启动一次温
本芯片可选 3 种工作模式:连续测温模式, 单次测温模式,关断模式。可根据速度或功耗 的需求灵活选择和配置。
应用领域
温控系统、工业过程控制、电源热保护、 环境温度检测等
描述
订购信息
SD5075 是一款高准确度温度传感器芯片, 内含高精度测温 ADC,在-40℃ ~ +100℃范围内
SOP8 封装
管脚图和管脚描述
VDD A0 A1 A2
8
7
6
5
SDIC XX
5075
1
2
3
4
SDA SCL ALARM GND
图 1. 管脚图
版本 v1.1b tel:13713800286
2017/01
序号. 1 2 3 4 5-7 8
管脚名称 SDA SCL
ALARM GND A2-A0 VDD
SD5075
表 1. 管脚描述
新的温度值产生后,会跟过温阈值寄存器/ 迟滞阈值寄存器的值相比较,并根据比较结果 和配置寄存器 bit4-bit1 的设置发出报警信号, 见图 3。
比较模式:当测量温度值高于过温阈值寄 存器,ALARM 输出有效电平;当测量温度值 低于迟滞阈值寄存器时,ALARM 管脚输出默 认电平。关断模式不影响该管脚状态。
-55℃
1100 1001 0000 XXXX
-40℃
1101 1000 0000 XXXX
-25℃
1110 0111 0000 XXXX
-0.0625℃
1111 1111 1111 XXXX
0
0000 0000 0000 XXXX
0.0625℃
0000 0000 0001 XXXX
25℃
0001 1001 0000 XXXX
版本 v1.1b 2017/01 tel:13713800286
第3页共3页
SD5075
地址指针寄存器: 8 位地址指针寄存器只能写,不能读,该
寄存器用于设置要读或者写的寄存器地址,具 体见表 3。
地址指针 寄存器 00H 01H 02H 03H 04H