分析化学课后习题答案(第7-12章)

合集下载

分析化学第五版课后习题答案

分析化学第五版课后习题答案

分析化学第五版课后习题答案第1章分析化学概论2.有0.0982mol/L的H2SO4溶液480mL,现欲使其浓度增至0.1000mol/L。

问应加入0.5000mol/LH2SO4的溶液多少毫升?解:c1V1c2V2c(V1V2)0.0982mol/L0.480L0.5000mol/LV20.1000mol/L(0.480LV2),V22.16mL4.要求在滴定时消耗0.2mol/LNaOH溶液25~30mL。

问应称取基准试剂邻苯二甲酸氢钾(KHC8H4O4)多少克?如果改用解:H2C2O42H2O做基准物质,又应称取多少克?nNaOH:nKHC8H4O41:1m1n1McV1M0.2mol/L0.025L204.22g/mol1.0gm2n2McV2M0.2mol/L0.030L204.22g/mol1.2g应称取邻苯二甲酸氢钾1.0~1.2gnNaOH:nH2C2O42H2O2:1m1n1McV1M20.2mol/L0.025L126.07g/mol0.3g2m2n2McV2M20.2mol/L0.030L126.07g/mol0.4g220.3~0.4g应称取2246.含S有机试样0.471g,在氧气中燃烧,使S氧化为SO2,用预中和过的H2O2将SO2吸收,全部转化为H2SO4,以0.108mol/LKOH标准溶液滴定至化学计量点,消耗28.2mL。

求试样中S的质量分数。

HCO2HO解:SSO2H2SO42KOHwnM100%m00.108mol/L0.0282L32.066g/mol100%0.471g10.3%8.0.2500g不纯CaCO3试样中不含干扰测定的组分。

加入25.00mL0.2600mol/LHCl溶解,煮沸除去CO2,用0.2450mol/LNaOH溶液反滴定过量酸,消耗6.50mL,计算试样中CaCO3的质量分数。

解:CaCO32HCl,NaOHHCl(cVcV)MnMw100%100%m0m0(0.2600mol/L0.025L0.2450mol/L0.0065L)100.09g/mol100%0.2500g98.24%10.不纯Sb2S30.2513g,将其置于氧气流中灼烧,产生的SO2通入FeCl3溶液中,使Fe3+还原至Fe2+,然后用0.02000mol/LKMnO4标准溶液滴定Fe2+,消耗溶液31.80mL。

分析化学第七章习题答案

分析化学第七章习题答案

分析化学》第七章习题答案(华中师范大学、东北师范大学、陕西师范大学、北京师范大学)(共13页)-本页仅作为预览文档封面,使用时请删除本页-第七章氧化还原滴定1.条件电位和标准电位有什么不同影响电位的外界因素有哪些答:标准电极电位E′是指在一定温度条件下(通常为25℃)半反应中各物质都处于标准状态,即离子、分子的浓度(严格讲应该是活度)都是1mol/l(或其比值为1)(如反应中有气体物质,则其分压等于×105Pa,固体物质的活度为1)时相对于标准氢电极的电极电位。

电对的条件电极电位(E0f)是当半反应中氧化型和还原型的浓度都为1或浓度比为,并且溶液中其它组分的浓度都已确知时,该电对相对于标准氢电极电位(且校正了各种外界因素影响后的实际电极电位,它在条件不变时为一常数)。

由上可知,显然条件电位是考虑了外界的各种影响,进行了校正。

而标准电极电位则没有校正外界的各种外界的各种因素。

影响条件电位的外界因素有以下3个方面;(1)配位效应;(2)沉淀效应;(3)酸浓度。

2.是否平衡常数大的氧化还原反应就能应用于氧化还原滴定中为什么答:一般讲,两电对的标准电位大于(K>106),这样的氧化还原反应,可以用于滴定分析。

实际上,当外界条件(例如介质浓度变化、酸度等)改变时,电对的标准电位是要改变的,因此,只要能创造一个适当的外界条件,使两电对的电极电位超过,那么这样的氧化还原反应也能应用于滴定分析。

但是并不是平衡常数大的氧化还原反应都能应用于氧化还原滴定中。

因为有的反应K虽然很大,但反应速度太慢,亦不符合滴定分析的要求。

3.影响氧化还原反应速率的主要因素有哪些?答:影响氧化还原反应速度的主要因素有以下几个方面:1)反应物的浓度;2)温度;3)催化反应和诱导反应。

4.常用氧化还原滴定法有哪几类这些方法的基本反应是什么答:1)高锰酸钾法.2MnO4+5H2O2+6H+==2Mn2++5O2↑+8H2O.MnO2+H2C2O4+2H+==Mn2++2CO2+2H2O2) 重铬酸甲法. Cr2O72-+14H++Fe2+===2Cr3++Fe3++7H2OCH3OH+Cr2O72-+8H+===CO2↑+2Cr3++6H2O3)碘量法 3I2+6HO-===IO3-+3H2O,2S2O32-+I2===2I-+S4O62Cr2O72-+6I-+14H+===3I2+3Cr3++7H2O5.应用于氧化还原滴定法的反应具备什么条件?答:应用于氧化还原滴定法的反应,必须具备以下几个主要条件:(1)反应平衡常数必须大于106,即△E>。

无机及分析化学第十二章沉淀滴定和重量滴定课后练习与答案

无机及分析化学第十二章沉淀滴定和重量滴定课后练习与答案

第十二章沉淀溶解平衡与沉淀滴定法一、选择题1.下列说法违反无定形沉淀条件的是()A. 在浓溶液中进行B. 在不断搅拌下进行C. 陈化D. 在热溶液中进行2.下列不属于沉淀重量法对沉淀形式要求的是()A.沉淀的溶解度小B.沉淀纯净C.沉淀颗粒易于过滤和洗涤 D.沉淀的摩尔质量大3.指出下列哪一条不是晶形沉淀所要求的沉淀条件()A.沉淀作用宜在较稀溶液中进行 B.应在不断地搅拌作用下加入沉淀剂C.沉淀应陈化 D.沉淀宜在冷溶液中进行4.在重量法测定硫酸根实验中,硫酸钡沉淀是()A.非晶形沉淀B.晶形沉淀C.胶体D.无定形沉淀5.晶形沉淀的沉淀条件是()A.浓、冷、慢、搅、陈 B.稀、热、快、搅、陈C.稀、热、慢、搅、陈 D.稀、冷、慢、搅、陈6.用 SO42-沉淀 Ba2+时,加入过量的 SO42-可使 Ba2+沉淀更加完全,这是利用()A.络合效应B.同离子效应 C.盐效应D.酸效应7.在重量分析中,待测物质中含的杂质与待测物的离子半径相近,在沉淀过程中往往形成()A.后沉淀 B.吸留 C.包藏 D.混晶8. 为了获得纯净而易过滤、洗涤的晶形沉淀,要求()A.沉淀时的聚集速度小而定向速度大B.沉淀时的聚集速度大而定向速度小C.溶液的过饱和程度要大D.沉淀的溶解度要小9.下列哪些要求不是重量分析对称量形式的要求()A.要稳定B.颗粒要粗大C.相对分子质量要大D.组成要与化学式完全符合10. 恒重是指样品经连续两次干燥或灼烧称得的重量之差小于()。

A. 0.1mgB. 0.1gC. 0.3mgD. 0.3g11. 有利于减少吸附和吸留的杂质,使晶形沉淀更纯净的选项是()A.沉淀时温度应稍高B. 沉淀完全后进行一定时间的陈化C.沉淀时加入适量电解质D. 沉淀时在较浓的溶液中进行12.重量分析中,依据沉淀性质,由()计算试样的称样量。

A.沉淀的质量B.沉淀的重量C.沉淀灼烧后的质量D.沉淀剂的用量13.在重量分析中能使沉淀溶解度减小的因素是()。

分析化学课后习题答案(第六版-李发美)

分析化学课后习题答案(第六版-李发美)

第十章紫外-可见分光光度法1.名词解释:吸光度、透光率、吸光系数(摩尔吸光系数、百分吸光系数)、发色团、助色团、红移、蓝移。

2.什么叫选择吸收?它与物质的分子结构有什么关系?物质对不同波长的光吸收程度不同,往往对某一波长(或波段)的光表现出强烈的吸收。

这时称该物质对此波长(或波段)的光有选择性的吸收。

由于各种物质分子结构不同,从而对不同能量的光子有选择性吸收,吸收光子后产生的吸收光谱不同,利用物质的光谱可作为物质分析的依据。

3.电子跃迁有哪几种类型?跃迁所需的能量大小顺序如何?具有什么样结构的化合物产生紫外吸收光谱?紫外吸收光谱有何特征?电子跃迁类型有以下几种类型:σ→σ*跃迁,跃迁所需能量最大;n →σ*跃迁,跃迁所需能量较大,π→π*跃迁,跃迁所需能量较小;n→ π*跃迁,所需能量最低。

而电荷转移跃迁吸收峰可延伸至可见光区内,配位场跃迁的吸收峰也多在可见光区内。

分子结构中能产生电子能级跃迁的化合物可以产生紫外吸收光谱。

紫外吸收光谱又称紫外吸收曲线,是以波长或波数为横坐标,以吸光度为纵坐标所描绘的图线。

在吸收光谱上,一般都有一些特征值,如最大吸收波长(吸收峰),最小吸收波长(吸收谷)、肩峰、末端吸收等。

4.Lambert-Beer定律的物理意义是什么?为什么说Beer定律只适用于单色光?浓度C与吸光度A线性关系发生偏离的主要因素有哪些?朗伯-比耳定律的物理意义:当一束平行单色光垂直通过某溶液时,溶液的吸光度A与吸光物质的浓度c及液层厚度l成正比。

Beer定律的一个重要前提是单色光。

也就是说物质对单色光吸收强弱与吸收光物质的浓度和厚度有一定的关系。

非单色光其吸收强弱与物质的浓度关系不确定,不能提供准确的定性定量信息。

浓度C与吸光度A线性关系发生偏离的主要因素(1)定律本身的局限性:定律适用于浓度小于0.01 mol/L的稀溶液,减免:将测定液稀释至小于0.01 mol/L测定(2)化学因素:溶液中发生电离、酸碱反应、配位及缔合反应而改变吸光物质的浓度等导致偏离Beer定律。

《无机及分析化学》1-12章习题答案

《无机及分析化学》1-12章习题答案
15. As2S3(H2S为稳定剂) 的胶团结构: [(As2S3)m ·nS2- ·(2n-x)H+]x- ·xH+
第一章 气体和溶液 (15页)
17. 聚沉能力由大到小排列: A. 100 mL0.005mol·L-1KI 和100 mL0.01mol·L-1
AgNO3 制成的为正溶胶,所以排列顺序为: AlCl3 K3[Fe(CN)6] MgSO4 (电荷同由小到大) B. 100 mL0.005mol·L-1 AgNO3和100 mL0.01mol·L-1 KI制成的为负溶胶,所以排列顺序为: K3[Fe(CN)6] AlCl3 MgSO4(电荷同由大到小)
13.
2SO2(g) + O2(g) = 2SO3(g)
n平衡
1.90
0.95 1.10
K K p( p ) B K C ( Rp T ) B
c(ScO (2S)O c3()O2)RpT1
1.1208.0 010.31 1.2 90.9 58.31151 00.5 031
第三章 化学反应速率和化学平衡 (56页)
V=1425∕900=1.58 L
c=1 25.2 0∕1.5.81 0 =.0 151 .80m1 o8 l·.L6 0 -1 0 9. 40.:0 6.6 00 :5.33 1:2:1
T bm B 0 .05 0 1 .50 00 M K b m A0 .51 9 .0 20 1g 8 m 0-1o
⑸ 减小容器体积
n(Cl2)增大
⑹ 减小容器体积
p(Cl2)增大
⑺ 减小容器体积
K⊖不变
⑻ 升高温度
K⊖增大
⑼ 升高温度
p(HCl)增大
⑽ 加N2 ⑾ 加催化剂

分析化学课后习题答案(第7章)

分析化学课后习题答案(第7章)

7.1 计算下列重量因数:测定物 称量物(1)FeO Fe 2O 3(2)KCl (→K 2PtCl 6→Pt ) Pt(3)Al 2O 3 Al(C 9H 6ON)3 (4)P 2O 5 (NH 4)3PO 4·12MoO 3答案:232(FeO)271.85(1)0.8999(Fe O )159.69M M ⨯== 2(KCl)274.55(2)0.7643(Pt)195.08M A ⨯== 23963(Al O )101.96(3)0.11102(Al(C H ON))2459.44M M ==⨯ 254343(P O )141.94(4)0.037822((NH )PO 12MoO )21876.3M M ==⨯ 7.2 称取某可溶性盐0.3232g ,用硫酸钡重量法测定其中含硫量,得BaSO 4沉淀0.2982g ,计算试样含SO 3的质量分数。

答案:3443(SO )(BaSO )(BaSO )(SO )100%0.29820.3430 100%31.65%0.3232s M m M w m =⨯⨯=⨯= 7.3 用重量法测定莫尔盐(NH 4)2SO 4·FeSO 4·6H 2O 的纯度,若天平称量误差为0.2mg ,为了使灼烧后Fe 2O 3的称量误差不大于0.1%,应最少称取样品多少克?答案:323424423234244230.210100%0.1%(Fe O )2(NH )SO FeSO 6H O0.210100%(Fe O )0.1%2((NH )SO FeSO 6H O)0.210 100%1(g)1600.1%2392s s M m M m M M ---⨯⨯≤⋅⋅⨯≥⨯⋅⋅⨯=⨯=⨯⨯ 7.4 计算下列微溶化合物在给定介质中的溶解度(除(1)题外均采用I =0.1时的常数)。

(1) ZnS 在纯水中(p K 0sp (ZnS)=23.8,H 2S 的p K a1=7.1,p K a2=12.9);(2) CaF 2在0.01mol ·L -1 HCl 溶液中(忽略沉淀溶解所消耗的酸);(3) AgBr 在0.01mol ·L -1 NH 3溶液中;(4)BaSO4在pH7.0,EDTA浓度为0.01mol·L-1的溶液中;(5)AgCl在0. 10 mol·L-1的HCl溶液中。

分析化学各章练习题及答案

分析化学各章练习题及答案

章节试题及答案(仅供练习参考)1、误差是衡量 ··········································································································· ( )A.精密度B.置信度C.准确度D.精确度2、偏差是衡量 ··········································································································· ( )A.精密度B.置信度C.准确度D.精确度3、下列论述中错误的是 ························································································· ( )A.单次测量结果的偏差之和等于零B.标准偏差是用于衡量测定结果的分散程度C.系统误差呈正态分布D.偶然误差呈正态分布4、下列论述中正确的是 ··························································································· ( )A.总体平均值通常用σ表示B.正态分布中正误差和负误差出现的概率相等C.标准偏差通常用μ表示D.分析结果落在 μ±σ范围内的概率为%5、下列论述中正确的是 ························································································· ( )A.系统误差加减法的传递是分析结果的绝对偏差为各测量步骤绝对偏差的代数和B.偶然误差乘除法的传递是分析结果的相对偏差为各测量步骤相对偏差的代数和C.置信度是以自由度来表示的D.少量实验数据是按t 分布进行统计处理6、下列论述中错误的是 ························································································· ( )A.平均值的置信区间是μ=x ±nμσ B.少量实验数据的平均值的置信区间是μ= x ±n t f⋅αS C.平均值与标准值的比较要用F 检验实验法是比较两组数据的方差S 27、根据分析天平的称量误差(±)和对测量的相对误差(%),下列论述中正确的是·····························································································································()A.试样重量应≥B.试样重量应≥C.试样重量应<D.试样重量就≥8、下列论述中,有效数字位数错误的是·····························································()A.[H+]=×10-2(3位)=(3位)(2位) =×10-5(2位)9、下列表达中最能说明偶然误差小的是·······························································()A.高精密度B.标准偏差大C.仔细较正过所有法码和容量仪器D.与已知含量的试样多次分析结果的平均值一致10、下列论述中最能说明系统误差小的是·····························································()A.高精密度B.标准偏差大C.仔细校正过所有砝码和容量仪器D.与已知含量的试样多次分析结果的平均值一致11、定量分析中精密度和准确度的关系是·····························································()A.准确度是保证精密度的前提B.精密度是保证准确度的前提C.分析中,首先要求准确度,其次才是精密度D.分析中,首先要求精密度,其次才是准确度12、若试样的分析结果精密度很好,但准确度不好,可能原因是 ···················()A.试样不均匀B.使用试剂含有影响测定的杂质C.使用未校正的容量仪器D.有过失操作13、分析测定中论述偶然误差正确的是·······························································()A.大小误差出现的几率相等B.正误差出现几率大于负误差C.负误差出现几率大于正误差D.正负误差出现的几率相等14、下列论述中错误的是·······················································································()A.方法误差属于系统误差B.系统误差包括操作误差C.系统误差又称可测误差D.系统误差呈正态分布15、下述情况,使分析结果产生负误差的是·······················································()A.用HCL标准溶液滴定碱时,测定管内壁挂水珠B.用于标定溶液的基准物质吸湿C.测定H2C2O4·H2O摩尔质量时,H2C2O4·2H2O失水D.滴定前用标准溶液荡洗了锥瓶16、对SiO2标样(SiO2%=)测定5次,结果如下:(x1)%,(x2)%,(x3)%,(x4)%,(x5)%。

分析化学分析化学全书 各章习题及答案

分析化学分析化学全书 各章习题及答案

第 1 页共19 页分析化学习题第一章概论练习题及答案一、基础题1、下列论述中正确的是:()A、准确度高,一定需要精密度高;B、精密度高,准确度一定高;C、精密度高,系统误差一定小;D、分析工作中,要求分析误差为零2、在分析过程中,通过()可以减少随机误差对分析结果的影响。

A、增加平行测定次数B、作空白试验C、对照试验D、校准仪器3、下列情况所引起的误差中,不属于系统误差的是()A、移液管转移溶液之后残留量稍有不同B、称量时使用的砝码锈蚀C、滴定管刻度未经校正D、以失去部分结晶水的硼砂作为基准物质标定盐酸4、下列有关随机误差的论述中不正确的是()A、随机误差是随机的;B、随机误差的数值大小,正负出现的机会是均等的;C、随机误差在分析中是无法避免的;D、随机误差是由一些不确定的偶然因素造成的5、随机误差是由一些不确定的偶然因素造成的、2.050×10-2是几位有效数字()。

A、一位B、二位C、三位D、四位6、用25ml移液管移出的溶液体积应记录为()ml。

A、25.0B、25C、25.00D、25.0007、以下关于偏差的叙述正确的是()。

A、测量值与真实值之差B、测量值与平均值之差C、操作不符合要求所造成的误差D、由于不恰当分析方法造成的误差8、分析测定中出现的下列情况,何种属于随机误差?( )A、某学生几次读取同一滴定管的读数不能取得一致B、某学生读取滴定管读数时总是偏高或偏低;C、甲乙学生用同样的方法测定,但结果总不能一致;D、滴定时发现有少量溶液溅出。

9、下列各数中,有效数字位数为四位的是()A 、10003.0-⋅=+L mol c HB 、pH=10.42C 、=)(MgO W 19.96%D 、0. 040010、下列情况引起的误差不是系统误差的是( )A 、砝码被腐蚀;B 、试剂里含有微量的被测组分;C 、重量法测定SiO2含量是,试液中硅酸沉淀不完全;D 、天平的零点突然有变动二、提高题11、滴定分析法要求相对误差为±0.1%,若使用灵敏度为0.0001g 的天平称取试样时,至少应称取( )A 、0.1g ;B 、 0.2g ;C 、 0.05g ;D 、 1.0g12、由计算器算得(2.236×1.1124)/(1.03590×0.2000)的结果为12.00562989,按有效数字运算规则应将结果修约为:( )A 12.006B 12.00;C 12.01;D 12.013、有关提高分析准确度的方法,以下描述正确的是( )。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

第七章原子吸收与原子荧光光谱法1.解释下列名词:(1)原子吸收线和原子发射线;(2)宽带吸收和窄带吸收;(3)积分吸收和峰值吸收;(4)谱线的自然宽度和变宽;(5)谱线的热变宽和压力变宽;(6)石墨炉原子化法和氢化物发生原子化法;(7)光谱通带;(8)基体改进剂;(9)特征浓度和特征质量;(10)共振原子荧光和非共振原子荧光。

答:(1)原子吸收线是基态原子吸收一定辐射能后被激发跃迁到不同的较高能态产生的光谱线;原子发射线是基态原子吸收一定的能量(光能、电能或辐射能)后被激发跃迁到较高的能态,然后从较高的能态跃迁回到基态时产生的光谱线。

(2)分子或离子的吸收为宽带吸收;气态基态原子的吸收为窄带吸收。

(3)积分吸收是吸收线轮廓的内的总面积即吸收系数对频率的积分;峰值吸收是中心频率ν0两旁很窄(dν= 0)范围内的积分吸收。

(4)在无外界条件影响时,谱线的固有宽度称为自然宽度;由各种因素引起的谱线宽度增加称为变宽。

(5)谱线的热变宽是由原子在空间作相对热运动引起的谱线变宽;压力变宽是由同种辐射原子间或辐射原子与其它粒子间相互碰撞产生的谱线变宽,与气体的压力有关,又称为压力变宽。

(6)以石墨管作为电阻发热体使试样中待测元素原子化的方法称为石墨炉原子化法;反应生成的挥发性氢化物在以电加热或火焰加热的石英管原子化器中的原子化称为氢化物发生原子化法。

(7)光谱通带是指单色器出射光束波长区间的宽度。

(8)基体改进剂是指能改变基体或被测定元素化合物的热稳定性以避免化学干扰的化学试剂。

(9)把能产生1%吸收或产生0.0044吸光度时所对应的被测定元素的质量浓度定义为元素的特征浓度;把能产生1%吸收或产生0.0044吸光度时所对应的被测定元素的质量定义为元素的特征质量。

(10)共振原子荧光是指气态基态原子吸收的辐射和发射的荧光波长相同时产生的荧光;气态基态原子吸收的辐射和发射的荧光波长不相同时产生的荧光称为非共振原子荧光。

2.在原子吸收光谱法中,为什么要使用锐线光源?空心阴极灯为什么可以发射出强度大的锐线光源?答:因为原子吸收线的半宽度约为10-3 nm,所以在原子吸收光谱法中应使用锐线光源;由于空心阴极灯的工作电流一般在1~20 mA,放电时的温度较低,被溅射出的阴极自由原子密度也很低,同时又因为是在低压气氛中放电,因此发射线的热变宽∆λD、压力变宽∆λL和自吸变宽都很小,辐射出的特征谱线是半宽度很窄的锐线(10-4~10-3 nm)。

加上空心阴极灯的特殊结构,气态基态原子停留时间长,激发效率高,因而可以发射出强度大的锐线光源。

3.试从原理和仪器装置两方面比较原子吸收分光光度法与紫外-可见分光光度法的异同点。

答:(1)相似之处:a. 都是吸收光谱;b. 工作波段相同190-900 nm;c. 仪器的主要组成部分相同,光源、单色器、吸收池、检测器;d. 定量分析公式相似A = Kc。

(2)不同之处:a. 吸收机理不同,分子吸收为宽频吸收,带状光谱,而原子吸收为窄带、峰值吸收,线状光谱;b. 仪器组成部分的排列不同,分子吸收为光源-单色器-吸收池-检测器,原子吸收为锐线光源-原子化器(吸收池)-单色器-检测器(单色器作用不同);c. 光源不同,分子光谱为连续光源,钨灯、氢灯,原子光谱为锐线光源,空心阴极灯;d. 光源的工作方式不同,分子光谱为直流信号,原子光谱为交流信号;e. 检测器不同,分子光谱为宽频吸收,信号强,普通光电池、光电管。

光电倍增管,原子光谱为窄带吸收,信号弱,必须用光电倍增管。

4. 简述原子吸收光谱法的准确度一般优于原子发射光谱法的主要原因何在?答:在原子吸收测量条件下,测量对象是占原子总数99%以上的基态原子,而原子发射光谱测量的是占少数的激发态原子,温度的变化主要影响激发态原子数的变化,而它们在原子吸收测量条件下占原子总数不到1%,对基态原子数的影响很小,因此原子吸收光谱法的准确度要优于原子发射光谱法。

5. 简述原子吸收峰值测量法的基本原理。

答:原子峰值吸收测量是在中心频率ν0两旁很窄(d ν = 0)范围内的积分吸收测量,此时K ν = K 0。

在原子化器中吸收线的变宽以多普勒变宽∆λD 为主,根据经典理论,峰值吸收系数K 0与∆νD 成反比,与积分吸收成正比,⎰⋅∆=νπννd K K D2ln 20,由于K ν = K 0,代入kN K D⋅∆=πν2ln 20可得kNl A D⋅⋅∆=πν2ln 2434.0,合并常数后得 Kc A =,即原子吸收峰值测量的基础。

6. 说明原子吸收光谱仪的主要组成部件及其作用。

答:原子吸收光谱仪主要由(1)锐线光源,发射谱线宽度很窄的元素共振线;(2)原子化器,将试样蒸发并使待测元素转化为基态原子蒸气;(3)分光系统,使锐线光源辐射的共振发射线正确地通过或聚焦于原子化区,把透过光聚焦于单色器的入射狭缝,并将待测元素的吸收线与邻近谱线分开;(4)检测系统,将待测光信号转换成电信号,经过检波放大、数据处理后显示结果;(5)电源同步调制系统,消除火焰发射产生的直流信号对测定的干扰。

7. 在原子吸收光谱仪和原子荧光光谱仪中对光源如何进行调制?为什么要进行光源调制?答:采用和空心阴极灯同频率的脉冲或方波调制电源,组成同步检波放大器,仅放大调频信号,为了消除原子化器中的原子发射干扰。

8. 试比较石墨炉原子吸收光谱分析法与火焰原子吸收光谱分析法的优缺点,并说明GF -AAS 法绝对灵敏度高的原因。

答:(1)石墨炉原子吸收光谱分析法的优点是:试样用量少,液体几微升,固体几毫克;原子化效率几乎达到100%;基态原子在吸收区停留时间长,约为10-1 s ,因此绝对灵敏度极高。

缺点是:精密度较差,操作也比较复杂。

(2)火焰原子吸收光谱分析法的优点是:对大多数元素有较高的灵敏度,应用广泛,但原子化过程中副反应较多,不仅使气态基态原子数目减少,使测定方法的灵敏度降低,而且会产生各种干扰效应。

9. 哪些测定条件影响原子吸收光谱分析的灵敏度? 答:(1)分析线,通常选择元素的共振吸收线作为分析线以得到最好的灵敏度;(2)单色器光谱通带,合适的光谱通带可提高灵敏度;(3)灯电流,尽量使用最低的灯电流;(4)原子化条件,在火焰原子吸收中,选择使入射光束从基态原子密度最大区域通过的原子化条件以提高分析的灵敏度,在石墨炉原子吸收法中,在保证完全原子化条件下尽量使用低的原子化温度。

10. 下列说法正确与否?为什么?(1)原子化温度越高,基态气态原子密度越大;(2)空心阴极灯工作电流越大,光源辐射的强度越大,测定的灵敏度越高; (3)原子吸收分光光度计用调制光源可以消除荧光发射干扰; (4)原子荧光分光光度计可不用单色器;(5)采用标准加入法可以提高分析方法的灵敏度;(6)原子荧光发射强度仅与试样中待测元素的含量有关,而与激发光源的强度无关。

答:(1)错,在原子吸收光谱中,基态气态原子密度N 0受温度影响很小,基本不随温度变化; (2)错,空心阴极灯的电流太大,放电不稳,信噪比严重下降,灵敏度降低;(3)错,在原子吸收分光光度计中用调制光源是为消除原子化器中的原子发射干扰; (4)对,由于原子荧光的谱线比较简单,可不用单色器;(5)错,标准加入法的测定中是在同一条件下进行,因此并不能提高分析方法的灵敏度,而它能消除基体干扰和某些化学干扰,故可以提高分析的准确度。

(6)错,N l k I A I f 0ϕ=,N 与c 成正比,所以 c l k I A I f 0ϕ=,f I 与0I 也成正比。

11. 原子吸收光谱分析法中,背景干扰是怎样产生的?如何抑制和校正光谱背景?简述用氘灯校正背景吸收的原理。

答:原子吸收光谱分析法中的背景干扰是由原子化过程中产生的分子吸收和固体微粒产生的光散射引起的干扰。

在实际工作中,多采用改变火焰类型、燃助比和调节火焰观测区高度来抑制分子吸收干扰,在石墨炉原子吸收光谱分析中,常选用适当基体改进剂,采用选择性挥发来抑制分子吸收的干扰;在原子吸收光谱分析中,可采用仪器调零吸收法、邻近线校正背景法、氘灯校正背景法和塞曼效应校正背景法等方法来校正背景。

氘灯校正背景是采用双光束外光路,氘灯光束为参比光束。

氘灯是一种高压氘气气体(D 2)放电灯,辐射190~350 nm 的连续光谱。

切光器使入射强度相等的锐线辐射和连续辐射交替地通过原子化吸收区。

用锐线光源测定地吸光度值为原子吸收和背景吸收的总吸光度值,而用氘灯测定的吸光度仅为背景吸收值,这是因为连续光谱被基态原子的吸收值相对于总吸光度可以忽略不计。

仪器上直接显示出两次测定的吸光度之差,即是经过背景校正后的被测定元素的吸光度值。

12. 试从原理和仪器装置两方面比较AAS 法和AFS 法的异同点。

答:(1)AAS 法和AFS 法是基本原理完全不同的两种分析方法,前者基于气态基态原子对辐射的吸收,后者基于气态基态原子在辐射能激发下产生荧光发射,属于发射光谱分析法。

(2)AAS 法和AFS 法所用仪器相近,均有光源、原子化器、分光系统、检测系统和电源同步调制系统组成,不同的是AAS 用的是锐线光源,AFS 除可以使用锐线光源外,还可以使用连续光源;仪器位置不同,在AFS 中,激发光源置于与分光系统(或与检测系统)相互垂直的位置,而AAS 中,在同一直线方向上。

13. 计算火焰温度2000 K 时,Ba 553.56 nm 谱线的激发态与基态原子数的比值。

已知g i /g 0 = 3。

解: eV nms cm eV hcE i 24.256.553100.310136.411015=⋅⨯⨯⨯==--λ)200010618.824.2(exp 3)(exp 1500KK eV eVT Eg g N N i i i ⨯⋅⨯-=-=--κ61081.6-⨯=14. 在火焰温度3000 K 时,Cu 324.75 nm 谱线的热变宽为多少?(M Cu = 63.54) 解: CuD M T71016.7λλ-⨯=∆ 54.63300075.3241016.77nm⨯⨯=- nm 3106.1-⨯=15. 原子吸收分光光度计的单色器的倒线色散率为1.6 nm ⋅mm -1,欲测定Si 251.61 nm 的吸收值,为了消除多重线Si 251.43 nm 和Si 251.92 nm 的干扰,应采取什么措施? 解:已知SD W ⋅=,nmnm W 18.0)43.25161.251(1=-=,nm nm W 31.0)61.25192.251(2=-=代入可得 mm D W S 113.011==,mm DWS 194.022== 要使测定Si 251.61 nm 的吸收值时,多重线Si 251.43 nm 和Si 251.92 nm 不产生干扰,则应使狭缝宽度小于0.113 mm 。

相关文档
最新文档