DC swing gate operator,battery back-up & solar power• 115/230 V AC (switch selectable) input power or 24 VDC solar power • 1/2 HP quadra drive heavy-duty DC motor• S plit housing allows easy access without having to remove the gate arm• E asy to adjust electronic magnetic limits eliminate old style mechanical switches that can wear out, break or fail • H eavy-duty steel frame • 0.0 Amp SBPD circuit (solar power only)• S olar power ready • 5-Y ear limited warranty6524 VEHICULARAC/DC SWING GA TE OPERA TORACCESS CONTROL SOLUTIONSEasy to Operatemanual releaseRESIDENTIAL • COMMERCIALSteel Frame for strength and durabilityGate Tracker TMrecord users accessDC Motor & Battery Backupfor continued gate operation ifAC power is lostMECHANICALPrimary reduction is provided by a pulley / belt driving a 60:1 worm gear reduction system running in a continuous oil bathThe 6524 rotates the gate 90° in approximately12-14 secondsOperator mechanics are mounted on a steel frame plated for corrosion resistanceT wo-piece articulating arm mechanical slow-start /slow-stop functionMounting: operator requires a concrete mounting pad Keyed access is provided to release arm for manual gate operation in the event of a power outageSplit polypropylene housing simplifies installation and maintenance, no need to remove the gate armUnique breakaway hub helps to protect the gear box if the gate is rammedGATE TRACKER TMReporting output provides operator data to aDKS 1833, 1835, 1837 or 1838 access control system (requires 2358 expansion board)OPTIONS18 Ah batteries (operator includes two (2) 7.5 AhSLA batteries)Solar kit (Includes two 18 Ah batteries and10 watt, 24 VDC solar panel)ELECTRICALEasy adjustable electronic magnetic limit switchesAuto-close timer 1-30 secondsGate overlap feature for dual (bi-parting) gate operation Selectable shadow / reverse loop functionDC power shut-off switchBattery protection circuitPorts for plug-in open and reverse loop detectors.DKS plug-in detectors onlyAC Powered Operator Only115 V AC convenience outletsAC power shut-off switchMagnetic lock powerDC Powered Operator Only0.0 Amp SBPD PatPend circuit MISCELLANEOUSEnvironmental: 10°F to 115°F (-12°C to 46°C) Thermostatically controlled heater kit required for operation below freezing temperatures to prevent batteries from freezing. Heater kit can only be used with AC powered operatorsShipping weight approximately 175-225 lb (79-102 kg) depending on model and options selectedOperator requires monitored T ype B1 and/or T ype B2 entrapment protection devicesConforms T o ANSI/CAN/UL 325:2017 Ed. 7Certified T o CSA C22.2 #247DISTRIBUTED BY:MEMBER:DoorKing,® Inc.Access Control Solutions since 1948120 S. Glasgow Avenue,Inglewood, California 90301 U.S.A.Tel: 310-645-0023 FAX: 310-641-1586© 2020 All Rights Reserved.Product specifications maychange without notice. Rev. 6/20TECHNICAL FEATURES。
哈雷冲压系统调试手册

目录
1. 修改记录 .............................................................................................................................................. 5 2. 总说明.................................................................................................................................................. 5 3. 概要 ..................................................................................................................................................... 6
Id.-No.: Id.-No.: Id.-No.: Id.-No.: Id.-No.:
79-0000-0014-00 79-0000-0015-00 79-0000-0016-00 79-0020-0009-00 79-0020-0010-00
ECOplus 保留变更的权利
ECOplus, HKL, HBL, HCC HRE
固件 P0135-xx 系统手册
o 对液压冲头实现智能式控制
o 支持液压系统:ECOplus,HKL,HBL,HCC,HRE,HSE
o 数据总线接口:RS-232 / CAN / Profibus
o 用 HS3-A CAN - HS3-A Profibus - PCU30-A Profibus - PCU20-A CAN Bus
亚瑟 美国92系列电动阀门驱动器操作和维护手册说明书

Quarter Master Chief Series 92 ActuatorInstallation, Operationand Maintenance ManualTable of ContentsSeries 92 Electric Actuator Introduction (3)Description (3)Electrical Requirement (3)Installation (4)Electrical (4)Type 21 Ball Valve (4)Type 23 Ball Valve (3-way) (5)Type 57 / 57L Butterfly Valves (5)Actuator Mounting Dimensions (6)Operation (7)Manual Override Operation (7)Setting Limit Switches (7)Options (8)Single Limit Switch (8)Double Limit Switch (8)Heater and Thermostat (8)Mechanical Brake (9)Feedback Potentiometer (9)Series 92 Options Codes for Serial # Tags (10)Troubleshooting (10)Maintenance (12)ATEX Requirements (12)Spare Parts (13)Series 92 Electric Actuator IntroductionDescriptionThe Series 92 electric actuators feature a reversing,capacitor run motor, with a permanently lubricated gear train, and hardened steel spur gears. These actuators are equipped with integral thermal overload protection (AC models) with automatic reset, independently adjustable limit switches, declutchable manual override, beacon position indication, baked powder epoxy coating with stainless steel trim, ISO bolt circle, and 2 (two) ½” NPT conduit entries.Standard models are offered in 115 VAC, feature a combination enclosure of Nema-4X, 7 & 9, and, provide up to 2000 in-lbs. of output torque.Various options are available such as operating voltages, additional limit switches, heater and thermostat, feedback potentiometers, etc.Please see page 8 regarding these options.Electrical RequirementWARNING: Do not open actuator cover while circuits are energized.CAUTION: Proper voltage must be supplied to actuator or damage will result.CAUTION: If 115vac & 220vac models are PLC driven, output contacts of PLC should be rated at a minimum of 1.5 times required input voltage of actuatorNOTE: To conform to various electrical codes, a green grounding screw has been provided (on the baseplate) inside of actuator.Terminal Strip Wiring: 75° C Copper Supply Wires up to #14 AWG, wired as per the attached diagrams or the wiring diagram affixed inside of actuator cover. Control Wiring shall be insulated with conductors rated 105° C, 300 V minimum.Torque Terminal Strip Wiring to 5 in-lbs.115 Vac 230 Vac 12 Vdc 24 Vdc 12 Vac 24 Vac Cycle Timeper 90 Model Torque Amp Duty Amp Duty Amp Duty Amp Duty Amp Duty Amp DutyDegrees (in/lbs) Draw Cycle Draw Cycle Draw Cycle Draw Cycle Draw Cycle Draw Cycle (seconds) S92 400 0.5 100% 0.4 100% 2.075% 4.075% 2.075% 3.0 75% 10A92 700 0.8 75% 0.6 75% 2.075% 4.075% 2.075% 3.0 75% 10B92 1100 0.5 100% 0.4 100% 2.075% 4.075% 2.075% 3.0 75% 25C92 2000 1.0 50% 0.6 50% 2.075% 4.075% 2.075% 3.0 75% 25 NOTE: Amp rating is considered locked rotor.Duty cycles are for ambient temperature (73°F)InstallationElectricalReference Drawing #289S92Models S-92, A92, & B921A. To gain access to terminal strip (Part #24) it is necessary to remove manual override knob (Part #18) by loosening slotted setscrew (Part #39). Remove 2 cover screws and cover; the remaining 6 cover screws are packaged inside the actuator. Torque cover/base screws to 120 in-lbs.Note: Failure to properly tighten cover/base flange fasteners to 120 in/lbs may compromise the certified safety factors of the actuator.Model C921B. To gain access to terminal strip it is necessary to remove manual override hand wheel (Part #18A) by loosening slotted setscrew (Part #39). Remove cam (Part #51) by loosening 2 set screws (Part #52). Remove 2 cover screws and cover; the remaining 6 cover screws are packaged inside the actuator.Torque cover/base screws to 120 in-lbs.All Models2. Make electrical connections to terminal strip as shown on wiring schematiclocated inside the cover (per various electrical codes there is a green screw on the actuator base plate for grounding purposes). Terminals are suitable for up to #14 AWG wire. All units are completely calibrated prior to shipment, and no internal adjustments should be required.3. For United States units, Install 1/2" NPT conduit fitting(s) to actuator base.For ATEX Certified European Union units, Install M20 x 1.5 conduit fitting(s) to actuator base.Note: Proper conduit fitting must be used to maintain enclosure rating and not compromise the certified safety factors of the actuator(weatherproof, explosion proof or combination weather proof/explosion proof). NOTE: We recommend sealing conduit openings on units installed outdoors or exposed to large temperature swings (15ºF or more).We also recommend the Heater and Thermostat option in these applications. 4. Replace actuator (gasket if removed) cover, and install 8 cap screws suppliedand tighten securely to 120 in/lbs. For outdoor or wet locations it isrecommended prior to replacing the cover that the top shaft seal be cleaned and coated with silicone grease. Also clean shaft and lightly coat seal area of shaft with silicone grease. Unit is now ready for operation.Type 21 Ball ValvePosition the valve and the actuator to corresponding positions (either OPEN or CLOSED). The flats on the actuator shaft extension indicate valve positionType 21 Ball Valves (See Drawing #0107BV sizes ½” – 2”)Install mounting bracket #3 to actuator #2 using bolts #8 and washers #9. Insert coupling #4 on stem of valve #1 and then bolt valve #1 to mounting bracket #3 using bolts #5, nuts #7, and washers #6.Note: All bolts should be snug and not excessively over tightened.Type 21 Ball Valves (See Drawing #0113BV sizes 2-1/2” - 4")Install mounting bracket #3 to actuator #2 using bolts #8 and washers #9. Insert coupling #4 on stem of valve #1 and then bolt valve #1 to mounting bracket #3 using bolts #5, nuts #7, and washers #6.Note: All bolts should be snug and not excessively over tightened.Type 23 Ball Valve (3-way)Position the valve and the actuator to corresponding positions (either OPEN or CLOSED). The flats on the actuator shaft extension indicate valve positionType 23 Ball Valves (3-way): (See Drawing #0130BV, sizes ½” - 4”)Install mounting bracket #3 to actuator #2 using bolts #8 and washers#9. Insert coupling #4 on stem of valve #1 and then bolt valve #1 tomounting bracket #3 using bolts #5, nuts #7, and washers #6.Type 57 / 57L Butterfly ValvesCAUTION: If valve is in line, system must be shut down and have no line pressure before removing throttle plate and retaining washer.Position the valve and the actuator to corresponding positions (either OPEN or CLOSED). The flats on the actuator shaft extension indicate valve position Butterfly Valves (See Drawing # 0200BF57 sizes 1-1/2” - 6”)No specially machined stem or valve body drilling required. Remove handle (remove handle cap and hex head bolt) to expose throttle plate screws. Remove throttle plate and retaining washer to expose existing bolt pattern.Mount bracket #3 to actuator #2 with bolts #8 and washers #9 and tighten evenly. Insert coupling #4 into actuator #2.Install valve #1 onto mounting bracket #3 and align stem of valve to engage with coupling. (Line scribed on top of stem indicates disc orientation). Install bolts #5, washers #6 and nuts #7 and tighten evenly. Flats on actuator shaft indicate valve position. (Disc Orientation)Butterfly Valves (See Drawing #0168BF57 8” size)No specially machined stem or valve body drilling required. Remove gear operator by removing 4 thru bolts in body of valve to gear operator and lift off. Mount bracket #2 to actuator #10 using bolts #7 and washers #8. Insert actuator shaft adapter #9 into actuator #10. Install valve #1 to mounting bracket #2 and align stem of valve to engage with coupling. (Line scribed on top of stem indicates disc orientation). Install bolts #3, washers #4 & #5 and nuts #6 and tighten evenly. Flats on actuator shaft indicate valve position. (Disc Orientation) CAUTION: If mounted unit is installed other than straight up, the actuator should be supported independently to prevent side loading and loosening up ofOperationManual Override OperationReference Drawing #289S92Models S-92, A92, & B92Pull up the declutching knob (Part #18) and apply a 5/8" open end wrench to exposed flats and rotate within labeled limits as indicated by arrows.To re-engage simply rotate actuator shaft in the opposite direction until declutching knob drops back down into position.Model C92Push down on hand wheel (Part #18A) and rotate within labeled limits.To re-engage simply rotate actuator hand wheel until it moves up and re-engages.CAUTION: The manual override should only be used when there is no power applied to actuator. When power is restored the actuator will automatically resume normal operation.Setting Limit SwitchesReference Drawing #289S92Open Travel Limit Switch (Top Switch Part #25):Using declutchable manual override, move the valve into a full open position. Then loosen set screws on top cam (Part #40) and rotate cam (CCW) into limit switch arm until a click is heard, this designates the switch circuit has opened and defines a full open position. Tighten 2 set screws (Part #40) on cam.Close Travel Limit Switch (Bottom Switch Part #25):Using declutchable manual override, move the valve to a full closed position, loosen set screws on bottom cam (Part #40) and rotate cam (CW) into limit switch arm until a click is heard, this designates the switch circuit has opened and defines a full closed position. Tighten 2 set screws (Part #40) on cam.Manually position valve to midstroke. Reapply power to actuator and drive to open or closed position. Actuator motor will run. The shaft will not turn until drivepins (Part #7) reseat in drive gear. This could take up to 25 seconds.OptionsModels S92, A92, B92, C92Single Limit SwitchInstall additional limit switch on posts on opposite side of standard limit switches using screws provided.Wiring for switch is as follows:Pink = Common to Terminal #6Purple = NC to Terminal #7Blue = NO to Terminal #8Cam must be set so that this switch is tripped just ahead of Closed limit switch. Wire tie loose wiring and check operation before installing cover.Double Limit SwitchInstallation and wiring is the same as for the single limit switch, with the additionof wiring of the second switch as follows:Brown = Common to Terminal #9Green = NC to Ternimal #10Orange = NO to Terminal #11Cam must be set so that this switch is tripped just ahead of Open limit switch. Wire tie loose wiring and check operation before installing cover.Heater and ThermostatModels S92 & A92Install Heater into threaded hole located between actuator base gasket andmotor module.Wiring is as follows:Heater lead = Terminal #12Thermostat lead = Terminal #13Wire tie loose wiring and check operation before installing cover.Models B92 & C92Install Heater into threaded hole located between actuator shaft and motor module.Wiring is as follows:Heater lead = Terminal #12Thermostat lead = Terminal #13Wire tie loose wiring and check operation before installing cover.Mechanical BrakeLoosen two (2) motor screws diagonally from each other and install bracket with tabs facing upward. Tighten screwsInstall hexagonal adapter over armature shaft and tighten set screws.NOTE: The adapter should be resting on the step of the armature shaft.Install brake assembly onto hexagonal adapter making sure that the brake assembly is sitting flush on the bracket. Tighten with supplied screws.Remove motor leads “A” & “B” from capacitor and install “piggy back connectors to capacitor, the re-install motor leads to their original locations.Connect brake leads to piggy back connectors on capacitor (orientation does not matter)Wire tie loose wiring and check operation before installing cover.Feedback PotentiometerUsing 4-40 x 3/8 hardware, install potentiometer and bracket on standoffs by limit switches, with potentiometer gear facing output shaft.Install drive gear face down over output shaft.Wiring for potentiometer as follows:#1 on potentiometer (black) #14 on terminal strip.#2 on potentiometer (white) #15 on terminal strip.#3 on potentiometer (red) #16 on terminal strip.Using multimeter set at 2k ohms, calibrate potentiometer with leads from meter connected to terminals #15 and #16. With actuator in closed position multimeter should read between 95 and 100 ohms.Rotate actuator 90 degrees (open position).Connect leads from multimeter to terminal #14 and #15; multimeter should read 95 to 100 ohms.If necessary adjust open limit switch cam so that multimeter will read 95-100 ohms.Series 92 Options Codes for Serial # TagsExample 1: S92HTP XWJHeater & thermostat and feedback potentiometer installed.Example 2: A92BRM1XWJMechanical brake and 1 extra limit switch installed.Troubleshooting WARNING: Do not open actuator cover while circuits are energized.Q: What if there is no output, but the motor runs?A: Manual override possibly engaged.When the manual override is engaged, the motor will run, but no output will be observed until the manual override re-engages with the output shaft.A: Valve stem broken. When the valve stem is broken, there will not be a change in fluid movement, making it seem as if the actuator has no output..Q: What if valve does not cycle?A: No power source to actuator. Check for power.A: Power source disconnected. Check for broken wire, loose connection or no connection as per appropriate wiring diagram.A: Low or wrong power source. Check for proper voltage.A: Mechanical Brake jammed or misaligned. Check alignment of brake assembly.This could occur during installation when someone would rest their hand on the Mechanical Brake to steady themselves. M1 1 extra limit switchM2 2 extra limit switches HT Heater & thermostat P Feedback potentiometer DP Dual feedback potentiometers C1 4-20 mA Positioner C3 4-20mA Output Transmitter BR Mechanical brake L2 2-Position Indicating Lights CO Center offCL Cycle length control 2W 2-wire control FS Failsafe Battery Pak A4 4-12mA Input Signal Positioner B12 Split Range Positioner ASI AS-I Bus Network CardQ: What if there is water and/or moisture inside of the unit?A: Conduit fitting installed improperly. Re-install correctly.A: Cover and/or base seal damaged. Replace damaged seal(s).A: Base gasket damaged or installed improperly. Check gasket and replace if necessary.A: Temperature swings of more than 15 degrees F. Install heater and thermostat to eliminate condensation.When these temperature swings occur, the unit will “sweat” on the inside causing internal corrosion unless the actuator is equipped with a heater and thermostat to keep a constant temperature inside of the housing.A: Unit has been submerged. Raise unit above liquid level.An actuator that is to be submerged MUST meet NEMA 6 for the proper protection of the actuator and the elimination of a potential hazard. We do not recommend submerging the Series 92 Actuator as the electrical rating does not meet NEMA 6.Q: What if unit is oscillating?A: Valve torque exceeds output torque of actuator. Check for chemical compatibility of valve, and flange torque.Q: What if thermal overload frequently cuts out motor?A: Frequency of operation exceeds duty cycle rating. Check cycling period.A: Unit is oscillating. Refer to above.Q: What if motor hums and no output is observed?A: Foreign material caught in valve. Remove material and inspect valve for damaged and/or worn parts. Replace parts as necessary.A: Unit wired incorrectly (simultaneously powering open and closed). Check wiring as per appropriate wiring diagram.A: Capacitor worn. Replace.Q: What if actuator “over-shoots” limit switches without stopping?A: Actuator wired in parallel to each other. Please note that each actuator requires it’s own set of switch contacts.MaintenanceDisconnect power!WARNING: Do not open actuator cover while circuits are energized. ArrayCAUTION: It is imperative for reducing the chance of electrical shock, and to prevent ignition of hazardous atmospheres that youDisconnect powerbefore any maintenance or repairs are performed.Series 92 actuators are virtually maintenance free. We do however, recommend that periodic checks are made to ensure that all fasteners are tight and properly torqued to extend the life of the actuator and valve.Series 92 Actuators are manufactured with factory lubricated grease in the gear case and gearbox. In most cases, this lubricant should never have to be replenished, however if deemed necessary, we recommend using Aeroshell Grease #33 MS, mfg. by Shell Oil Co.Consult our technical department before replenishing lubricant.For outdoor or wet locations keep top and bottom seals coated with a silicone based grease.ATEX RequirementsATEX Standard EEx d IIB Directive II 2 G Certified UnitsService/Maintenance/Inspection RequirementsAbove directive for hazardous location service electric actuators, for use throughout the European Union.All electric actuators are to be used for remote operation of a valve to open or closed positions. Any other uses are not approved by Asahi/America, Inc.Every 250,000 cycles or 10 years whichever comes first, the actuator must be removed from service and sent back to Asahi/America, Inc. for inspection of wear of bearings as they relate to joints and gaps in accordance with above directive. Any units not within normal tolerances, will need to be re-built or replaced at theusers expense.Spare PartsReference Drawing #289S92We recommend that the following be kept on hand as spare parts.1 --- Limit Switch (Part #25)1 --- Capacitor (Part #27 or #28)NOTE: When ordering replacement motor parts and/or options specify model # and voltage.Attachments:9 drawings: 0043EL, 0044EL, 0042EL, 0107BV, 0113BV,0130BV, 0168BF57, 0200BF57, 289S92。
帕顿2030双向线驱动器 转换器用户手册说明书

SALES OFFICE (301) 975-1000TECHNICAL SUPPORT (301) 975-1007Part # 07M2030-BDoc. #102121U,Rev. CRevised 1/22/08An ISO-90011.0 WARRANTY INFORMATIONPatton Electronics warrants all Model 2030 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.1.1 RADIO AND TV INTERFERENCEThe Model 2030 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 2030 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 2030 does cause interference to radio or television reception, which can be determined by disconnecting the RS-232 interface, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).1.2 CE NOTICEThe CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.1.3 SERVICEAll warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Support: (301) 975-1007; ; or,******************.Notice: Packages received without an RMA number will not be accepted.Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 2030. Technical Service hours: 8AM to 5PM EST, Monday through Friday.2.0 GENERAL INFORMATIONThank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions arise during installation or use of the unit, contact Patton Electronics Technical Support at (301) 975-1007.2.1 FEATURES• Supports Data Rates to 115.2 Kbps• Supports two IEEE 1284 BiTronics®Modes:Compatible and Nibble (switchable)• 4KV ESD Protection on Serial Interface• Power Derived from Both Interfaces,or from External AC Power Supply• LEDs for Power and Data Mode (Distinctive Blinking)• Male Centronics®-36 or Mini-Centronics®-36for Parallel Connection• DEC®MMJ jack, RJ-45 jack, or DB-25 (male or female) for Serial Connection• Miniature Size• Made in USA2.2 DESCRIPTIONThe Patton Model 2030 RS-232/423 to IEEE 1284 BiTronics®Protocol Converter lets you connect RS-232/423 serial hardware to a printer or other device equipped with a BiTronics®parallel interface. Able to work in either Level 1 Compatible or Nibble modes (according to the IEEE 1284 Standard), the Model 2030 supports the high speeds necessary for graphics-intensive laser printer applications.On the serial side, the Model 2030 translated Nibble operations into standard Hewlett-Packard TM LaserJet®IV serial printer escape sequences. This allows operation with standard printer drivers. On the parallel side, the Model 2030 translates all commands received from the serial device into BiTronics®Nibble operations or Compatible operations (depending upon the mode selected).The Model 2030 works with all BiTronics®Level 1 compatible hardware, including Level 2 hardware with Level 1 backward compatibility. Power may be supplied by both interfaces, or by a plug-in AC adapter. A variety of interface connection options are available.3.0 CONFIGURATIONThe Model 2030 is simple to install and designed for excellent reliability. The following instructions will help you set up and install the converters properly. If you have any questions, please call Patton Technical Support at (301) 975-1007.3.1 CONFIGURATION SWITCHESThe Model 2030 uses a set of eight external DIP switches (see Figure 1) that allow configuration to a wide range of applications. Because all eight switches are in one externally accessible DIP switch package, there is no need to open the case for configuration. The configuration switches allow you to select data rates, parity, word length and flow control selection. The following section describes all switch locations, positions and functions.1.Open the Model 2030 case by inserting a small flat-bladescrewdriver in the slot on either side of the case and twistinggently.2.Having exposed the Model 2030 PC board, you will see theminiature DIP switch packet on the side of the board nearestthe Centronics®connector.3.To set the switches, use a small screwdriver and gently pusheach switch to its proper setting. The ON position is printedon the switch packet.4.Fit the case halves and end plate together and push to snapclosed.PATTON MODEL 2030 SPECIFICATIONSTransmission Asynchronous, Full Duplex on the serial Format:side; IEEE1284 BiTronics®on the parallelside, supporting Compatibility and NibbleModes (switchable)Connectors:Male Centronics®-36 or Mini-Centronics®-36 for Parallel Connection; DEC®MMJjack, RJ-45 jack, or DB-25 (male or female)for Serial ConnectionESD Protection:4KVData Rates:9.6, 19.2, 38.4 and 115.2 KbpsRange: Meets capacitive and resistive loadrequirements of RS-232 and RS-423Power Supply: Power derived from RS-232/423 and IEEE-1284 Interfaces. Note: IEEE 1284 Binterface must support the optional 5V onpin 18, and IEEE 1284 C must supportinterface pin 36 (peripheral logic high).Otherwise, power must be supplied usingthe optional AC wall mount power supply.Temperature Range:0-60°C (32-140°F)Altitude: 0-10,100 feetHumidity: 5 to 95% noncondensingDimensions: Approximately 3”H x 2”W x .75”DAPPENDIX BPATTON MODEL 2030INTERFACE CONNECTIONS36 PIN CENTRONICS PARALLEL PORT CONNECTIONS PinDescription Direction1Strobe Output 2Data bit 03Data bit 14Data bit 25Data bit 36Data bit 47Data bit 58Data bit 69Data bit 710Acknowledge Input (active low)11Busy Input (active high)12Paper end 13Select 16Logic Ground 17Chassis Ground 18+5 volts (19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30)31Init 32Error 36nSelectIn Note : All other pins are unconnectedI/O }}GroundNOTES_________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________Copyright ©1997Patton Electronics CompanyAll Rights Reserved.Dear Valued Customer,Thank you for purchasing Patton Electronics products! We do appreciate your business. I trust that you find this user manual helpful.We manufacture one of the widest selections of data communications products in the world including CSU/DSU's, network termination units, powered and self-powered short range modems, fiber optic modems, interface converters, baluns, electronic data switches, data-line surge protectors, multiplexers, transceivers, hubs, print servers and much more. We produce these products at our Gaithersburg, MD, USA, facility, and can custom manufacture products for your unique needs.We would like to hear from you. Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future.Web: Sales E-mail: ****************Support E-mail: ******************Phone - Sales (301) 975-1000Phone - Support (301) 975-1007Fax: (301) 869-9293Mail: Patton Electronics Company7622 Rickenbacker DriveGaithersburg, MD 20879 USAWe are committed to a quality product at a quality price. Patton Electronics is ISO 9001 certified. We meet and exceed the highest standards in the industry (CE, UL, etc.).It is our business to serve you. If you are not satisfied with any aspect of this product or the service provided from Patton Electronics or its distributors, please let us know.Thank you.Burton A.PattonVice PresidentP.S. Please tell us where you purchased this product:__________________________________________________________________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________________________________________________。
利密托克电动头调试说明(中文版)

ESD信号
禁止 OK?
YES
综合报警触点设置一般是不需要更改。综合报警触点已经包 含电源缺相、阀卡涩、电机超温故障报警,通常接(53、 54)端子,即有故障时触点闭合。除了以上三项报警信息 外,还有一下几项可以设置项目,就地(LOCAL)、停止 (STOP)和过扭矩。默认为按钮处于就地和停止位时触点闭 合,故障信号发出,这样的设计是为了将来设备正式投入使 用后,如果有人拨到就地或停止位,控制室就会有报警信 息,有利于监控。也可以根据客户需要进行更改,如果改为 禁止,在就地和停止位就不会有故障信号输出。还有过扭矩 选项,默认为禁止,即关闭状态,也可以更改到允许状态, 这样在电动头有过扭矩情况是也会有报警信号反馈到控制室 。禁止信号和ESD信号通常都是禁止状态,不需要进行更改
1 0 [0] 第三位数字-OK?
YES
1 [0] 0 第二位数字-OK?
YES
[1] 0 0
第一位数字-OK?
NO
[0] 0 0 第一位数字-OK?
更改
YES
阀门设置?
关方向
YES
关断方法
YES
打开方法
YES
(顺时针关)OK?
(阀位)-OK?
(阀位)-OK?
关方向 (逆时针关)-
OK?
关断方式 (扭矩)-OK?
YES-NO-YES
设置?
YES
设置
用中文?
YES
更改
YES
设置?
输入 口令?
口令为100 OK?
YES
YES
1 0 [0] 第三位数字-OK?
YES
1 [0] 0 第二位数字-OK?
YES
[1] 0 0
第一位数字-OK?
Comoso PAVC SERIES 可变体积气动驱动式驱动器说明书

Service Parts GuidePM 3040-25HydraulicsEffective:February, 1997P AVC SERIES VARIABLE VOLUME PISTON PUMPModel P AVC33 * * * * 25P AVC38 * * * * 15123 SECTION Y-YA, M, ME, AM & WPOSITIONCONTROL OPTION1234OMIT A C H M ME S SE AM HMCM OPEN 800599108X4108X4102X1800599OPEN 108X4108X4108X4108X4108X4108X4108X4OPEN OPEN 108X4OPEN 108X4OPEN OPEN OPEN OPEN786635786635OPEN800599800599OPEN 800599OPEN 800599800599800599OPEN102X1OPEN 800599102X1800599102X1102X1102X18005994SECTION Y-YCONTROL OPTIONS & SE56•Use a clean lubricant (compatible with the working fluid) on all pump components during assembly.•Thoroughly clean the reservoir, suction lines, suction strainer, drain lines, etc., before re-installing the pump. Most premature pump failures occur when contaminants from a previous failure have not been completely removed from the system, or cause for previous failure is still present (i.e. water in oil, bypassing filter, etc.).•Always fill the case with clean fluid before starting a new or serviced pump (fill as high as inlet port will allow on a P AVC style pump). For flooded suction, purge air from suction lines by cracking the inlet fitting or vent plug on pump body. This should prevent an airlock condition and allow for faster priming.•Check for proper shaft rotation, if there is a possibility it may have changed during a system rebuild.•Start pump with an open circuit whenever possible. Reduce the compensator to its minimum setting during start-up. Cycle the pump ON and OFF stroke while increasing the compensator to its required setting. This will assist in break-in of new components and help purge air from the case.NOTE:Pump shown is a left hand (CCW) rotation. For a right hand (CW) rotation pump, the port plate kidneys and outlet port orientation will be reversed.7892USE NITRILE SEALSOMIT PUMP DESIGN SERIES 4141111142437871997875717865141TRUNNION HSG.HOUSING-L.H.424310X2954CAP SCREW 78682410X29941TRUNNION HSG.ITEM PART NUMBER QTY DESCRIPTION HOUSING-R.H.5011786949N 786950NNON-ADJ.DIFF .ASSY ADJ.DIFF .ASSY524040786427PORT PLATE, CW 786428PORT PLATE, CCW ITEM PART NUMBER QTY DESCRIPTION R L46474849CAP SCREW SCREW HEX HEAD LOCKWASHER FLANGE O-RING221112X27536X107351252222N-75OMIT 555657111108X6N 787054N 787055NPLUGMAX.VOL.STOP "VAR.2" ASSY P AVC33P AVC382515O M I TMAX.VOL.STOP "VAR.5" ASSY2OMIT47071727323247677786952N 786953N 786951N 786956N 108X4N 800599786635PRESS COMP .ASSY TORQUE PLUG ASSY TORQUE CONTROL ASSY SERVO CONTROL ASSY STRAIGHT PLUG ORIFICE PLUG ORIFICE FITTING0MIT A C H M ME S SE AM CM HM REFER TO SECTION X-X& SECTION Y -YFOR LOCATION & COMBINATIONOF ABOVE COMPONENTSW102X1PIPE PLUG PM 3040-25 11/99 IGS Printed in USAParker Hannifin Corporation Hydraulic Pump/Motor Division 2745 Snapps Ferry Road Greeneville, TN 37745 USA T el:(423) 639-8151Fax:(423) 787-2418Web site: /pumpmotorHydraulics。
Copley+驱动调试帮助

Copley驱动调试帮助向导1.到/Motion/Products/Software/index.html 下载CME2软件并进行安装。
2.软件安装完成后,用RS232通讯线缆将驱动器与电脑串口相连,连接完成后给驱动器上电,再点击桌面“CME2”图标打开软件,如图1 所示:图1点击“OK”后,出现图2界面:图2(以XSL-230-18驱动为例)3.驱动器基本配置点击“Amplifier”菜单下“Basic Setup”或点击图标工具栏第一个图标,出现图3窗口:图3在图3中可以看到当前驱动器的配置情况,如要改变设置,请点击“Change Settings”,进入“Motor Options”设置,出现图4窗口:图4Motor Family(电机类别):Brushless:无刷电机Brush:有刷电机Three Phase Stepper:三相步进电机Motor Type(电机类型):Rotary:旋转电机Linear:线性电机再点击“Next”进入“Feedback Options”设置,出现图5窗口:图5Hall Type(Hall类型):None:没有HallDigital:数字HallAnalog:模拟Hall(Copley直线电机专用)当有Hall时,请勾上“Hall Phase Correction”。
Motor Encoder(电机编码器):None:没有Primary Incremental:主通道数字编码器接口Secondary Incremental:第二通道数字编码器接口Analog:模拟信号编码器接口Low Frequency Analog:低频模拟信号编码器接口(Copley直线电机专用)Position Encoder(位置编码器):None:没有Primary Incremental:主通道数字编码器接口Secondary Incremental:第二通道数字编码器接口Analog:模拟信号编码器接口Position Encoder Type(位置编码器类型):Rotary:旋转Linear:线性Use Position Encoder In Passive(Monitor)Mode:将位置编码器用于监控模式[注]:XSL,XSJ,ACP,ACJ四款驱动均有两个数字编码器通道,两个通道可任意配置为电机编码器或位置编码器。
科蒂斯说明书-1212P

测量篇 ------------------------------------ 23 注意事项 ---------------------------------- 27
1
安全指南
在开始操作前务必仔细阅读本手册! !
只有合格人员才允许安装和使用本产品。合格人员是指经过培 训,并按既定安全惯例和标准进行安装,调试和使用的人员。
34 制动电流限制
值越大,制动能力越强
BOOST CURRENT
35 峰值电流限制
值越大,爬坡及翻越障碍能力越强
BOOST TIME
36 峰值电流允许时间
超过时间则关闭 BOOST 功能
INHIBIT MENU
TYPE 37 速度抑制类型
速度限制设置用
最小值 最大值 缺省值 单 位
5
30
10
%
40
100
4
6
10
16
25
4
永磁电机
电机是将电池电能转换成机械能,驱动电动车车轮旋转的部件。 使用
电机的周围应保持清洁干燥,其内外部不应放置其它物件; 严禁与强磁性物体并存; 输入电压等级需确保正确; 使用中若发现电机有异常声音或气味,应立即停车检查; 电机和控制器之间的走线应尽可能短; 碳刷寿命约 2000H,需及时更换碳刷。
永磁电机控制器使用
说明书
1212/1212P 系列
2014 年 7 月版
1212 系列
永磁控制器 使用说明书
尊敬的用户:
您好! 欢迎您使用 CURTIS 控制器。为了您在使用我们的产品前,能够更好的了解 我们的产品,请您仔细的阅读本说明书,如有其它疑问,请随时与我们联系。
科蒂斯(中国)
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
Copley CME2调试软件用户向导Chinese Revision 1Nov 2009Written by Paul目录1.软件的安装、启动及向导 (4)1. 1 安装软件 (4)1. 2 启动CME2软件 (4)1. 3 串口设置 (4)1. 4 CAN网络参数配置 (6)1. 5 CME2连接到驱动器 (6)1. 6 CME2软件向导 (7)2.基本配置 (9)2.1 改变基本设置 (9)2.2 ServoTube电机配置 (12)3.电机/反馈参数配置 (14)3.1 电机/反馈参数窗口概览 (14)3.2 旋转电机参数设置 (14)3.3 直线电机参数设置 (15)3.4 反馈参数,旋转电机 (16)3.5 反馈参数,直线电机 (17)3.6 反馈注意事项 (17)3.7 Brake/Stop 参数 (18)3.8 Brake/Stop 注意事项 (18)3.9 计算功能 (19)4.数字输入/输出配置 (21)4.1 数字输入 (21)4.2 数字输出 (23)4.3 同步PWM开关频率 (28)5.电机相位 (29)5.1 用Auto Phase 整定电机相位 (29)5.2 选择Auto Phase时Current和Increment Rate值向导 (34)5.3 Auto Phase过程中的微调 (34)5.4 用Motor Phase Manually整定电机相位 (35)6.控制面板 (40)6.1 Control Panel 概览 (40)6.2 状态指示和消息 (41)6.3 Control Panel 监控通道 (41)6.4 控制功能 (42)6.5 Jog 模式 (42)7.控制环路 (44)7.1 电流环设置和调试 (44)7.2 电流环自动调节 (46)7.3 电流模式和电流环的注意事项 (48)7.4 速度环设置和调试 (50)7.5 速度模式和速度环的注意事项 (52)7.6 位置环设置和调试 (54)7.7 位置模式和位置环的注意事项 (59)8.驱动器错误 (62)8.1 错误参数配置 (62)8.2 错误锁定注意事项 (63)8.3 位置速度误差注意事项 (63)9. 命令输入 (66)9.1 模拟命令设置 (66)9.2 PWM输入设置 (68)9.3 数字位置输入设置 (69)9.4 软件编程输入设置 (71)10. CAN网络配置 (72)11. 回原点 (73)1.软件的安装、启动及向导1. 1 安装软件1.到/Motion/Products/Software/index.html下载CME2软件,解压缩后,双击“Setup.exe”文件进行软件安装。
1. 2 启动CME2软件1.双击电脑桌面上的CME2快捷方式图标,启动CME2软件,出现如图所示窗口:提示:当CME2软件运行时,键盘上的F12键可用做驱动器去使能用途。
2.点击上图中的“OK”后,如通讯端口已经被设置,可出现类似下图窗口:如果“基本设置”选项还未被配置,“基本配置”窗口便会自动弹出。
1. 3 串口设置1.如果串口或者CAN口还没有被选择,“通讯向导”窗口便会自动弹出,如下图所示:2.如果CME2的主界面已经打开,可以选择“Tools”菜单下的“Communication Wizard”。
3.选择“Serial Ports”然后点击“Next”,打开“Communication Wizard Select Ports/Serial Ports”窗口,如下图所示:4.从可用的串口中选择用于与驱动器通讯的COM口。
在可用的串口中选中后,点击“Add”,将要用的COM口添加即可;也可在所选的COM口中,点击“Remove”将其移除。
5.点击“Next”保存选项,并打开通讯向导的串口设置窗口,如下图所示:6.配置相应的COM口,设置其波特率。
7.点击“Finish”保存选项。
1. 4 CAN网络参数配置1.如果串口或者CAN口还没有被选择,“通讯向导”窗口便会自动弹出,如下图所示:2.如果CME2的主界面已经打开,可以选择“Tools”菜单下的“Communication Wizard”。
3.选择CAN Network4.点击“Next”,CAN 通讯窗口打开,如下图所示:5.选择合适的CAN 卡,通道和波特率,然后点击“Finish”。
注意:1)CAN Card 列出了已经和电脑相连并且已安装好相应驱动的生产商名称;2)所有的驱动器必须设置为同样的波特率(默认为:1Mbit/s)。
1. 5 CME2连接到驱动器驱动器与CME2的连接方式如下:当只有一个驱动器连接时,软件启动后会自动连接。
1. 6 CME2软件向导2.基本配置点击打开“基本配置“窗口,如下图所示:浏览当前的基本配置情况选择:a. 假如需要,点击“Change Settings”来改变当前的设置;b. 假如你有一个准备好的“.ccx”文件,可直接点击“Load ccx File”将文件直接下载到驱动器中;c. 假如要配置Servo Tube 电机,直接点击“ServoTube Setup”;d. 假如要接受当前显示的设置,直接选择“Cancel”。
2.1 改变基本设置1.点击“Change Settings”来改变驱动器的设置,不同的设置选项因不同的驱动器而改变。
2.设置电机选项3.设置反馈选项4.设置工作模式5.设置混合选项6.当配置好各选项后,点击“Finish”完成基本设置。
2.2 ServoTube电机配置ServoTube 电机配置主要针对于使用Copley ServoTube 直线电机。
1.在“基本设置”界面上,点击“ServoTube Setup”开始基本设置向导。
2.选择合适的电机系列和型号,“Invert Motor Direction”可选,可选的“Additional Encoder Option ”只适用于某些系列的电机,选择合适的分辨率的编码器(1micro meter 或者5micro meter)。
如下图所示:3.设置操作模式4.设置混合选项5.当对当前的设置满意后,点击“Finish”完成设置。
6.如要测试电机的运行,用Jog运行电机。
3.电机/反馈参数配置3.1 电机/反馈参数窗口概览如果系统安装了两个反馈原件,需要确认电机的转数和位置的距离是够对应,他们之间的关系用Ratio来表示。
3.6 反馈注意事项1.Encoder 和Resolver一些Copley驱动器提供了Encoder 和Resolver两种反馈方式的版本。
Encoder版本支持数字差分信号或者模拟sin/cos信号的编码器,并且此版本的驱动器通常需要Hall来整定无刷电机的相位。
Resolver版本支持独立的,单端的,发射型的Resolver。
2.双反馈型驱动器一些Copley驱动器可以通过主编码器通道,次编码器通道(multi-mode port),或者两个通道接收电机,负载,或者两者的位置反馈信号。
(一些驱动器可以工作在没有编码器和Resolver的模式)当驱动器被配置成带有multi-mode port时,multi-mode port可以:●提供基于数字编码器输入的编码器数字缓冲输出信号●提供基于模拟编码器或者Resolver的转换后的数字编码器输出信号●提供次编码器通道做为双编码器位置模式。
此模式下,位于负载端的编码器做为位置闭环,电机端编码器或者Resolver做为速度环反馈。
双闭环设置如下。
驱动器从主编码器通道端接收电机端增量式编码器信号,位置(负载)端编码器信号来自于Multi-mode Port(次编码器通道)。
电机转数与负载端编码器转数比例是1:10。
3.8 Brake/Stop 注意事项许多控制系统在驱动器去使能后需要刹车使电机保持。
在带刹车系统中,用硬件或软件指令去使能后以下序列事件将会发生:●电机开始减速(以位置模式的Abort Deceleration或者速度模式的Fast Stop Ramp减速)同时Brake/Stop Delay time计数开始,这使得电机在执行刹车之前先减慢速度。
●当电机减速到Brake Activation Velocity或者Brake/Stop Delay time溢出时,刹车输出有效并且PWM Delay Brake/Stop Response Time计数开始。
●当PWM Delay Brake/Stop Response Time到达时,驱动器PWM输出断开,这个延时保证了在驱动器PWM输出断开前刹车有足够的时间有效。
这个序列在电流模式下无效。
在电流模式下,当去使能信号有效后,驱动器输出断开,刹车也立即有效。
3.9 计算功能1. 点击“Calculate”计算并且显示设置。
2. 确认峰值电流限制,持续电流限制,和速度环速度限制。
假如这些参数中的一个或多个看上去不合理,点击“Cancel”并且检查:峰值力矩(力),持续力矩(力),速度限制,和力矩(力)常数。
假如必要的话修改它们。
(请看旋转电机设置参数或者直线电机设置参数)假如Motor/Feedback 值正确但是峰值电流限制,持续电流限制,或者速度环速度限制值对于当前的应用并不是最优化的,在调试的过程中改变它们。
3. 点击OK将这些值下载到驱动器的RAM中。
注意:当从一个文件中下载电机数据,假如文件中电机接线配置跟当前存在驱动器中的配置不匹配,CME提示确认正确的配置。
点击Yes选择配置文件,这些配置将被做为电机的相位部分进行测试。
4. 在主界面上,点击“Save to Flash”保存配置以防配置丢失。
4.数字输入/输出配置●点击“Input/Output”打开Input/Output窗口。
●需要的话,设置“Digital Inputs”。
●需要的话,设置“Digital Outputs”。
●点击“Close”,保存设置到驱动器的RAM中●在主界面上,点击“Save to Flash”保存配置以防配置丢失。
4.1 数字输入1. 数字输入界面概览3. 标准的输入功能分配Enable Input: 在大多数Copley驱动器中,IN1被专门配置为硬件使能输入。
Accelus系列默认IN2为硬件使能输入。
其它的输入口可被定义为额外的使能输入。
假如有多个输入被配置为硬件使能输入,当这些使能输入都有效时,PWM才有输出。
Motor Over Temperature: 在大多数Copley驱动器中,IN5位于电机反馈接头中,并被做为电机温度传感器接口。
Other:其它输入口的功能可根据驱动器的控制模式来确定。
4.2 数字输出1. 数字输出界面概览2. 标准输出功能标准输出功能描述如下:3. 数字输出配置:Custom Event驱动器的任意一个数字输出可以被定义响应一组事件,包括错误,报警和状态指示。