3.西门子S7-1200产品样本
SIMATIC S7-1200数字I O模块6ES7223-0BD30-0XB0的产品数据表说明书

08/18/2014
subject to modifications © Copyright Siemens AG 2014
DC 24 V 0 to 5 V 15 to 30 V
1 mA 0.5 A
Yes ; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four 2 µs 10 µs
Yes
Yes
500 m 300 m
08/18/2014
subject to modifications © Copyright Siemens AG 2014
Cable length unshielded, max.
150 m
Interrupts/diagnostics/status information
Alarms
Alarms
Product data sheet
6ES7223-0BD30-0XB0
SIMATIC S7-1200, DIGITAL I/O SB 1223, 2 DI / 2 DO, 2 DI 24V DC/2 DO 24V DC
-
Supply voltage permissible range, lower limit (DC) permissible range, upper limit (DC)
Climatic conditions for storage and transport
Free fall
Drop height, max. (in packaging)
0.3 m ; five times, in dispatch package
西门子1200资料ppt课件

13
14
UDT(用户自定义数据类型)
15
接上
16
中断
17
18
19
硬件中断一般用作紧急事件的处理
模拟量
22
• 用转换指令中的标定和标准转换 ,
23
pid
• 在项目树中工艺对象中添加PID 控制并组态 • 并在循环中断中调用
变量就可以
8
全局DB 1
9
全局DB 2
10
全局DB 3
11
全局DB和UDT
• 方便用上位机控制,用全局dp更程序地址关联上可以了
12
UDT(用户自定义数据类型)作用是变量 打包做个模板
• 如果FB多次调用 在全局变量中就要建很多变量 所以用UDT (把所 有变量打包)
1. 先建好要用 2. 在全局DB中建立相同数据类型的变量(这时候db中的一个变量
FC的实参(无参数调用)
在FC程序中直接输入变量地址
1
FC的形参(有参数调用) • 现在变量声明表中定义(变量表中的参数不具备存储数据的功能,必须外部
给它分配具体的地址存储数据,temp下的数据分配的L储存区的地址)。
2
FB与FC的区别 • FC如果有很多的中间变量 如果放在temp区 在主程序不能多次同时调用 ,会
4
多重背景
• 被调用的块的背景数据块集成在调用的块里,而实现对数据的集 中处理(调用的函数块将其数据保存在调用函数块的背景数据块中, 而不是自己的背景数据块中。 这可以让您将背景数据集中在一个 块中,并通过程序中较少的背景数据块获取。)
• FB1里多次调用FB2用多重背景做 1. 先把fb2做好 2. 在fb1的static里建变量数据类型选FB2 3. 在ob1主程序调fb1就可以运行
S71200选型用户手册(2017)

输入 / 输出扩展模块 SM(信号模块) SM 1221 数字量输入模块 SM 1222 数字量输出模块 SM 1223 数字量输入 / 直流输出模块 SM 1223 数字量输入 / 交流输出模块 SM 1231 模拟量输入模块 SM 1232 模拟量输出模块 SM 1231 热电偶和热电阻模拟量输入模块 SM 1234 模拟量输入 / 输出模块
附件 电源模块 PM 1207 输入仿真器 SIM 1274 存储卡
TIA 博途产品范围总览 TIA 博途安装的系统要求
SIMATIC HMI 系列面板
附录 附录 1 — 中央处理单元接线图
— 扩展模块接线图 附录 2 — 通用技术规范 附录 3 — 订货数据
4
11 12 13 13 14 14 14
LOGO! 8
PROFIBUS DP / RS485
PROFINET / TCP/IP
I/O能力,程序大小,指令速度,通讯能力, ...
SIMATIC S7-1200
SIMATIC S7-1200 具有集成 PROFINET 接口、强大的集成工艺功能 和灵活的可扩展性等特点,为各种工艺任务提供了简单的通信和有
输入 / 输出扩展模块 SB 及通信板 CB(信号板) SB 1221 数字量输入信号板 SB 1222 数字量输出信号板 SB 1223 数字量输入 / 输出信号板 SB 1231 热电偶和热电阻模拟量输入信号板 SB 1231 模拟量输入信号板 SB 1232 模拟量输出信号板 CB 1241 RS485 通信信号板
逻辑控制器的书本型迷你控制器 LOGO! 到基于 PC 的控制器,无 需求。在研发过程中充分考虑了系统、控制器、人机界面和软件的
西门子S7-1200 PLC编程与应用第2版课件02 S7-1200的硬件结构和安装维护

S7-200ຫໍສະໝຸດ S7-1200PLC的定位
扩
S7-300
展
性
最多可扩展7个模块
最多可扩展8个模块 (Rack0)
S7-1200
最多可扩展3个模 块(CM)
最多可扩展8个模块 (SM)
青岛大学-西门子先进自动化技术联合实验室
数
混合声明的数据类型使内存 非常杂乱
„Classic“ DB
据
块
的
存
组织化数据使内存消
青岛大学-西门子先进自动化技术联合实验室
安装端子板连接器示意图
青岛大学-西门子先进自动化技术联合实验室
2.4S7-1200 PLC的接线
安装现场的接线
在安装和移动S7-1200模块及其相关设备时,一定要切断所有的电源。 S7-1200设计安装和现场接线的注意事项如下
(1)使用正确的导线,采用1.50mm2 ~0.50mm2 的导线。 (2)尽量使用短导线(最长500米屏蔽线或300米非屏蔽线),导线要尽 量成对使用,用一根中性或公共导线与一根热线或信号线相配对。
电源功率的计算
CPU功率预算 CPU 1214C AC/DC/继电器
减 系统要求 CPU 1214C,14点输入 1个SM 1223,5V电源 1个SM 1223,8点输入 1个SM 1223,8点继电器输出
总要求 等于
电流差额 总电流差额
5 VDC 1600 mA
5 VDC -
145 mA -
145 mA
青岛大学-西门子先进自动化技术联合实验室
(3)将交流线和高能量快速开关的直流线与低能量的信号线隔开。 (4)针对闪电式浪涌,安装合适的浪涌抑制设备。 (5)外部电源不要与DC输出点并联用作输出负载,这可能导致反向 电流冲击输出,除非在安装时使用二极管或其它隔离栅。
S7-1200及扩展模块CAD图纸

S7-1200的选型与配置

S7-1200的选型与配置(1)本体硬件拓展S7-1211C=本体+1Board+3CM/CPS7-1212C=本体+1Board+3CM/CP+3SMS7-1214C/1215C/1217C=本体+1Board+3CM/CP+8SM相关说明:1Board(信号板):SB-DI/DO AI/AO CB-RS485SM:DI/DO AI/AO 拓展模块CM:RS422/485 RS232 Profibus等通讯模块CP:远程通讯模块(2)本体各类型的接线图相关说明:电源:20.4-28.8VDCPNP(图示)输入自带AI/AO自带24VDC输出电源晶体管24VDC输出端,0.5A/28.8VDC输入接线:PNP/NPN开关,按钮旋钮开关,触电的哇区别以及注意事项。
相关说明:电源:20.4-28.8VDCPNP(图示)输入自带AI/AO自带24VDC输出继电器输出:交直流均可以输出:2.0A/220VAC/30VDC相关说明:电源:85-264VDCPNP(图示)输入自带AI/AO自带24VDC输出继电器输出:交直流均可以输出:2.0A/220VAC/30VDC(3)拓展模块-SM数字量输入模块类型:均支持PNP/NPN逻辑1信号(最小):信号为1时最小电流及电压逻辑0信号(最大):信号为0时最大电流及电压隔离(现场侧与逻辑侧):光电隔离隔离组:通道之间不隔离滤波时间:将输入滤波时间设置为适合的值以避免高速计数器无法正常工作电缆长度:非屏蔽300m;屏蔽500m相关说明:1.24VDC输入接线与本体一样2.滤波时间需要在不同的应用情况下注意调整3.输入信号的电缆长度要注意考虑4.如果遇到交流220VAC的输入信号时建议通过中间继电器转成无源信号,然后用24VDC进行输入(当然,s7-1200PLC系列也有264VAC拓展模块可选)数字量输出模块1.电流:出点输出的最大电流2.通态触电电阻:通道内部电阻值3.每点的测电流:晶体管输出特性,当信号为0时通过的漏电流4.公共端的电流(最大):每个通道组输出的电流综合。
SIMATIC S7-1200基本控制器说明文档说明书

Basic Controller SIMATIC S7-1200Be flexible thanks to networking possibilities Unrestricted / © Siemens AG/s7-1200SIMATIC controllers set new automation scaleTrends Solutions…Ethernet-based field busIT functionality Increased functionality and designflexibilityIncreased Integrated functionalityOptimized usabilityEasy to manage, reduced complexityPROFINET I/O as a standard at all PLCse.g. web server on-board all PLCsFor the same priceMore interfaces, higher performance, memory …e.g. motion control functions / PID controller /Trace / high speed counterse.g. integrated system diagnostics, project upload Simplified commissioning (serial machine building) Reduced, optimized portfolioIncrease of system functionalityHighlight performance•PROFINET Master –decentralized Profinet architectures possible for I/O, HMI, drives, and other Profinet field devices. NO communication module required!•PROFIBUS Master & Slave –decentralized Profinet architectures possible for I/O, drives, and other Profinet devices, including integration into existing system networks.•AS-i Master –The new AS-i-Master is configured in full in the TIA Portal and a new AS-i network can be created very easily with just a few clicks. AS-i networks do not therefore require separate software!•CANopen Master –Enables connection with CANopen devices, as well as with devices running Transparent CAN 2.0A.Highlight performance•Modbus TCP –Enables communication with devices as Modbus master or slave. Only one TCP function block is required for this. •IO-Link Master –Fast and easy integration of the SIRIUS compact starter, M200D starter and SIRIUS soft starter for simple starter control.•GPRS/LTE module –Easy implementation for data recording and control of decentralized computer.•TCP/IP –Via the instructions for open communication you can communicate with other CPUs, other PCs and with devices that use TCP/IP communication protocols as standard. NO communication module required!SIMATIC S7-1200 in the TIA PortalHighlight performance•RS-485, RS-422 & RS-232 –The S7-1200 CPU supports point-to-point (PtP) communication for character-based serial protocols, and this provides maximum freedom and flexibility for the use of PtP communication instructions in the user program.•Modbus RTU –Using the Modbus instructions the Modbus master or slave is able to communicate with devices that use the Modbus RTU protocol.•USS –Using simple USS instructions you can control the operation of drives that support the USS (Universal Serial Interface) protocolS7-1200CPUSMCM CP SM 1278CB 1241 RS485SINAMICS V20USSMODBUS RTUModuleCommunicationCM 1241RS232serial CM 1241RS422/485serialCM 1243-2AS-i master CM 1242-5PROFIBUS DP slave CM 1243-5PROFIBUS DP masterCP 1242-7GPRS Mobile communications telecontrolCP 1243-7LTE Mobile communications telecontrolCP1243-1Ethernet VPN/Firewall, Telecontrol Ethernet (DNP3, IEC 60870)RF120C RFID 1 Reader port; RS422CM CANopenCANopen3rd party: HMS 021620-BS7-1200 integrated PROFINET (Ethernet) interface… with the STEP 7 software•CPU hardware configuration•Loading a project•Monitoring/amending runtime tags•Set runtime I/O statuses•Diagnostics information... with HMI panels•Data from or to the CPU•System diagnostics... from CPU to CPU•Open communication with T-block instructions•Supported protocols: TCP/IP, ISO on TCP, UDP, S7 Com. (PUT/GET)MRP -Media redundancy protocolBased on ring topology (IEC 61158-5-10)Max. 50 nodes in the ring•PROFINET IO-Controller•PROFINET IO-Devices•Components of the network infrastructure (IE switches) 200 ms reconfiguration timeCPU 1215/17 as MRP Client at least FW V4.1 Configuration and diagnostics in STEP7Industrial Ethernet PROFINET•Improved plant availability•More flexibility•Lower costs since less equipment required > V4.1< V4.2S7 routing•Enables a connection between different subnets • A SIMATIC S7-1200 station acts as an S7 router •Based on PROFINET•Actually only with CP 1243-1 at least V2.0 (6GK7243-1BX30-0XE0) andCPU FW V4.2192.168.0.1 192.168.0.3 177.168.0.1192.168.0.2S7 routedConnectionSubnet1Subnet 2CommunicationWebserverIntegrated Web server•Access to system and process reports as well as identification data •System diagnostics for all configured assemblies centrally anddecentralized•Communication diagnostics on parameters, statistics, connection status •Access to process data via tag tables and freely definable tag lists •Pages to be defined by the user•Firmware updateArchive•Access via Webserver using Filebrowser for reciprocal exchanges of data in .csv format•Logging of user-defined tagsStation webserverVarious types of communication access: CPU PN interface, CP 1243-7 LTE,CP1242-7 V2•Central access via CPU page independentlyof the interface•User is then able to browse to the CP-specific webpages from thereuniform, consistent webserverfor entireS7-1200 stationRemote access viaInternet/mobile communicationsPN accessPROFINET i-Device•Simple configuration of S7-1200 CPUsin a master/slave architecture through reading and writing the reciprocal I/O images•Connection of CPUs in different projects•NO PN-PN coupler required (transparent network)IO controllerCPU1IE / PROFINETIO deviceOperational systemApplication / userprogramIO process imageInputaddr.Outputaddr.Operational systemApplication / userprogramIO process imageInputaddr.Outputaddr.PROFINET IOIO controller 1IO device 2IE / PROFINETIO device 1IO device 3i-deviceSavings with costs / installation / wiring of additional hardwareCPU2•Access for up to 2 controllers on S7-1200 as i-device •Rapid exchange of data in real time between S7-1x00 CPUs•Incorporation of 3rd party controllers under PROFINETAs ofV4.1Shared I-DeviceSerial communication•ASCII protocol (character-based serial communication)uses STEP 7 PtP instructions•USS Drive protocol is programmed with STEP 7 USSlibrary instructions•MODBUS protocol is programmed with STEP 7MODBUS library instructions•3964R ProtokollRS232RS485/422USS drivesUpdate rate Array•Fixed update rate (as fast as possible)•Enable instructions in an interrupt alarm OB in order toset a user-defined update rate.Support for drives•Maximum 15 drives per CM (communication module) supported•Non support:•MM3 drives•Deregistration of missing drives•S7-1200 CPU up to 8 IO-Link master modules -centralized•Data rate COM1 (4.8 kbaud), COM2 (38.4 kbaud), COM3 (230.4 kbaud)•Standard IO Mode (SIO Mode)•up to 4 IO-Link devices (3 wire) or 4 standard actuators•Diagnostics configurable for each port •I&M identification•IO-Link parameter allocation with S7-PCT (Port Configuration Tool) V3.2IO-Link supportSM 1278 4xIO-Link master (6ES7 274-1XK30-0XA0)•Point-to-point connection, no bus system•Existing wiring topologies are retained•Standard sensor/actuator cable (three wires with one signal wire), unshielded, 20 m in length,no special-purpose cable / connector•Manufacturer-independent communication standard for the PNO•Non-stop consistent communication•Cyclical, bidirectional process data communication (typ.2 ms cycle)•Non-cyclical service data transmission betweensensors/actuators and the controller as required •Integrated differentiated diagnostics alarms• LinkSwitchingdevices<20 mControl cabinet<20 m3RA6compact starters3RA27function modules for feeders3UG4monitoring relays3RW40soft startersSIMATIC RF120C –Fast communication module for S7-1200RF120CInterface to the applicationInternal S7 busConnection technology S7-1200 setup technology; screw terminals for 24 V supply Interface to the reader RS422 incl. 24 Volt; up to 115.2 KBaud Connection technology Submin-D connectorRFID system RF200, RF300, RF600, MOBY D/U, MV400FB, driver Instructions: Read, Write, Read_EPC-Mem, Write_EPC-Mem, Set_Ant_RF300, Set_Ant_RF600, Reset_Reader; based on FB101Number of readers 1 per RF120C; 3 per S7-1200Degree of protection IP 20Dimensions (W x H x D)30 x 100 x 75•Level measurement in silos and bunkers •Plattform scales•Force and tension measurements •Typical industries: Food & Beverage,Chemicals, Cement, Aggregate•Legal for trade certificate according OIML-R76•CPU 1212C →up to two SIWAREX modules •CPU 1214C orhigher→up to eight SIWAREX modules •Full parameter access from the CPU via free downloadable function block →Complete commissioning andcalibration via CPU/HMISIWAREX WP231 –Basic applications•Up to eight parallel connected analog 350 Ohm load cells per SIWAREX (1mV/V, 2mV/V, 3mV/V or 4mV/V)• 1 SIWAREX = 1 scale• 4 digital inputs / 4 digital outputs • 1 analog output•Ethernet (Modbus TCP & SIWATOOL)•RS485 (Modbus RTU)SIWAREX WP241 –Belt weigherapplications•Belt scales (Cement-, Aggragate plants, Mines, Food & Beverage plants)•Weigh feeder applications (Food & Beverage, Chemical, Steel)•CPU 1212C →up to two SIWAREX modules •CPU 1214C or higher→up to eight SIWAREX modules •Full parameter access from the CPU via free downloadable function block →Complete commissioning andcalibration via CPU/HMI•Up to eight parallel connected analog 350 Ohm load cells per SIWAREX (1mV/V, 2mV/V, 3mV/V or 4mV/V)• 1 SIWAREX = 1 scale• 3 digital inputs / 4 digital outputs / 1 speed sensor input • 1 analog output•Ethernet (Modbus TCP & SIWATOOL)•RS485 (Modbus RTU)SIMATIC S7-1200SIWAREX WP251 –Dosing , Batching and Bagging applications•Dosing and batching scales (Chemical-, Food-, Pharma, Packaging industries)•Bagging machines (Bulk solids industries)•Eichfähig gemäß OIML-R51, R61 und R76•CPU 1212C →up to twoSIWAREX modules •CPU 1214C or higher→up to eight SIWAREX modules •Full parameter access from the CPU via free downloadable function block →Complete commissioning andcalibration via CPU/HMI•Up to eight parallel connected analog 350 Ohm load cells per SIWAREX (1mV/V, 2mV/V, 3mV/V or 4mV/V)• 1 SIWAREX = 1 scale• 4 digital inputs / 4 digital outputs • 1 analog output•Ethernet (Modbus TCP & SIWATOOL)•RS485 (Modbus RTU)•RS485 (Modbus RTU)•A CANopen connection to a S7-1200 systemenables integration between devices and the S7-1200 system •Up to 3 CANopen modules per S7-1200 CPU •Connection type to the CAN: 9-pin DSUB (male)•Up to 16 CANopen nodes per module•256 bytes each for inputs and outputs with the CANopen module•Can be integrated in the hardware catalog of the TIA Portal configuration suite •Ready-made function blocks for simple PLC programming available in the TIA Portal • LinkController Area Network CANopen 021620-BMODBUS communication•Use of a CM or CB 1241 module for serial communication•MODBUS instructions of the communication module for simplified MODBUS RTU operation.•MB_COMM_LOAD for basic initialization of the master and slave operation•MB_MASTER and MB_SLAVE for controlling the report and connection allocations•Modbus addressing supports a maximum of 247 slaves (slave numbers 1 to 247).•Maximum of 32 devices per segment in the Modbus network depending on the loading and drive functions of the RS485 interface•Repeater required if using more than 32 devices to extend to the next segment•Open User Communication MODBUS TCP instructions usethe PROFINET port integrated in the CPUOverview of CP 1243-1 product features•Single-width S7-1200 enclosure (30 x 110 x 75)•Temperature range in operation: -20°C to +70°C•Standard rail mounting•Diagnostic LEDs (overall status and detail)•Power supply using backplane bus•1 x Ethernet Port RJ45 (10/100 Mbit/s) for connectinga modem/router such as SCALANCE M•Integrated security functions (VPN and Firewall)•Integration to Scada Systems via Telecontrol Protokolls(DNP3, IEC 60870)Communication Processor for connecting S7-1200 to Ethernet network withadditional Interface and security features firewall and VPN. Integration toScada Systems via Telecontrol Protokolls (DNP3, IEC 60870, TelecontrolBasic).Overview of CP 1243-7 product features•1 connection to LTE (4G) mobile network(different versions for EU and North America)•Single-width S7-1200 enclosure (30 x 110 x 75)•Temperature range in operation from -20ºC to +70ºC•Standard rail mounting•Diagnostic LEDs (overall status and detail)•Integrated security functions (VPN and Firewall)•Access to the CPU Webserver•Email and SMS Alarms•Process Monitoring and Control via Cellular networkPROFIBUS DP-Master CM 1243-5•Connection for up to 16 DP slaves•PG/OP communication:up to 4 connection for HMI and 1 connection for PG •S7 communication:4 S7 connections to other S7 stations with PUT/GETPROFIBUS DP-Slave CM 1242-5•as an intelligent DP slave for communication for the S7-1200 with any other DP masterCommunication for S7-1200 CPUs according to PROFIBUS standard IEC61158/61784SIMATIC S7-1200PROFIBUS communication DP master CM 1243-5 and DP slave CM 1242-5Challenges need innovative answersIndividualization Globalization Production Logistics •Global alliance ofproduction and suppliers •New business modelsProduction•Customized mass production•Top quality at a competitive priceTime to Market New Technology•Critical to success inhighly competitive industries•Pressure on productivity increases, shortening time for new developmentSustainabilityEnergy Consumption•The efficient use of energy and environmentally safe materialsAlways the appropriate controller with comprehensive functionalities!Innovations across the entire automation life cycle!Engineered in TIA PortalSecurity IntegratedIntegrated system diagnosis Technology Integrated+Design and Handling+Safety IntegratedInnovative system functions for more productivity!Protecting intellectual property and investment Protecting against unauthorized project changesSecurity integratedFor Efficient fault analysis, Uniform display concept and reducing plant downtimesSystem DiagnosticsInvestment protection while replacing S7-1200 with S7-1500 thanks to compatibility of programsScalabilityUser-friendly products, high efficiency and a scalableproduct portfolioFeature / Function BenefitIntegrated PROFINET◆Web server for service-and diagnostic informationTechnology Integrated◆perfect integration of drives through motion control functionalities and PROFIdriveIntegrated Trace functionality◆Program-and application diagnostics at real-time for recognizing even sporadic problemsUse of all TIA Portal advantages◆Efficient programming, commissioning and service toolshighest engineering requirementsEasily adapted to suit your needsFeature / Function BenefitSystem ModularityModular board concept is integrated customization ◆Adding I/O without increasing theCPU footprintExtensive built-in hardwarecapabilitiesEthernet,analog in/out-puts, MC I/O, HSC I/O, SD memory ◆Reduced need for additionalspecialty modules,smaller footprintand lower costOne Engineering SoftwareOne user program for logic, HMI, networking & drives. ◆Reduced engineering time/cost, easier to maintain, easier to reuseSafety IntegratedOne Controller for fail-safe and standard-automation◆reduction of types-and components by single automation system for Standard and SafetyOne Controller for Standard andSafetyNewNewFeature / Function Benefit•Basic Controller with SafetyIntegrated•Connecting ext. devices viaPROFIsafe•CPU 1212CF◆•One Controller, one Network andone Engineering for standardand fail-safe automation tasks•Energy Meter ModuleSM1238 AI ◆•Central Measurement andHandling of energy data •MRP at 2 Port CPUs 1215 / 17as client (FW 4.2)•S7-Routing (FW 4.2)◆•Higher flexibility in network set-up (flexible topology) and highernetwork availability •Userdefined web pages as startpages (FW 4.2)◆•Individual and easy adaption of(CPU) web pages to applications•Backup / Restore with retaindata (FW 4.2)◆•Protection of data loss(incl actual process values)Easy PLC selection thanks to an optimized Portfolio2xTMCPU 1211C-1PN CPU 1212C-1PN CPU 1214C-1PN CPU 1215C-2PN CPU 1217C-2PN CPU 1212FC CPU 1214FC CPU 1215FCCSM PM 13x CM / CP22x I/Q 11x SB 1x CB 1x BBSM 1226 F-DO 2x Relay SM 1226F-DO 4 x 24 V DC SM 1226 F-DI 16 x 24 V DCMarienhöher Milchproduktion Agro Waldkirchen GmbH / Waldkirchen, Germany -S7-1200 and Energy Meter ModuleAllow internal balancingduring operation without high effort and cost1Efficient operation and cost optimization2ReliableSystem Protection3Transparency in energy consumption... through the acquisition of energy data in acompact solutionIncrease of energy efficiency ... through analysisof the reactive power consumptionGuaranteeing plant availability ... by monitoring the current peaksCPU 1212C with SM1238 Energy Meter ModuleCPU 1212C with SM1238 and visualization via KTP 400CPU 1212C with SM1238 and visualization via KTP 400ChallengePreviously Now -CPU 1212CJanitza UMG96SM 1238 Energy Meter -Basic Panel, KTP 400TIA Portal BasicProducts usedCustomer benefitsProducts/solution Energy data acquisition of direct marketing(butcher shop, diary, cheese factory, sales room), transparency and internal balancing in an agricultural enterprise End customer /F&BWaldkirchen/GermanyiProject informationSIMATIC Controller Get more Information…Always up-to-date!•interesting news from and about AS, such as product innovations, success news, best practice information etc.Newsletter/newsletter Detailed product information and related subjects!•Product Websites •Twitter, Youtube..Internet/S7-1200References CenterFrom customer to customer! •Customers gives account to there experiences using our Products for their applicationsGetting Started/automation-tasksEasy Introduction to the new SIMATIC controller generation!•Learn about the new possibilitiesand get to know the new Hardware even betterhttps:///referen zen/#language=enSubject to changes and errors. The information given in this document only contains general descriptions and/or performance features which maynot always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated companies or third parties. Their unauthorized use may infringe the rights of the respective owner.。
柳絮-S7-1200-6GK7277-1AA10-0AA0产品说明书

● at DC / at 24 V
Interfaces / others Number of electrical connections ● for power supply Type of electrical connection ● for power supply
Supply voltage, current consumption, power loss Type of voltage / of the supply voltage
Standards, specifications, approvals Standard
24 V 19.2 ... 28.8 V Yes 0.5 A / 60 V 0.07 A
1.6 W
0 ... 60 °C -40 ... +70 °C -40 ... +70 °C
95 %
IP20
SIMATIC S7-1200 device design 45 mm 100 mm 75 mm 0.15 kg
Product functions / management, configuration Product function ● multiport mirroring ● switch-managed
Product functions / Redundancy Product function ● Parallel Redundancy Protocol (PRP)/operation in the PRP-network ● Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
T-block 指令来实现,可用于 S7-1200 之间的通讯,S7-1200 与 S7-300/400 的通讯 • 3 个连接用于 S7 通讯的服务器端连接,可以实现与 S7-200, S7-300/400 的以太网 S7 通讯
集成 PROFINET 接口
集成的 PROFINET 接口用于编 程、HMI 通讯和 PLC 间的通 讯。此外它还通过开放的以太 网协议支持与第三方设备的通 讯。该接口带一个具有自动交 叉网线(auto-cross-over)功能 的 RJ45 连接器,提供 10/100 Mbit/s 的数据传输速率,支持 以下协议:TCP/IP native、ISO-on-TCP 和 S7 通讯。
存储器
为用户指令和数据提供高达 50 KB 的共用工作内存。同时还 提供了高达 2 MB 的集成装载内 存和 2 KB 的掉电保持内存。
SIMATIC 存储卡可选,通过不同 的设置可用作编程卡,传送卡和 硬件更新卡三种功能。通过它 可以方便地将程序传输至多个 CPU。该卡还可以用来存储各种 文件或更新控制器系统的固件。
6
集成工艺
高速输入 SIMATIC S7-1200 控制器带有多 达 6 个高速计数器。其中 3 个 输入为 100 kHz,3 个输入为 30 kHz,用于计数和测量。
高速输出 SIMATIC S7-1200 控制器集成 了两个 100 kHz 的高速脉冲输 出,用于步进电机或伺服驱动 器的速度和位置控制。(使用 PLCopen 运动控制指令)这两 个输出都可以输出脉宽调制信 号来控制电机速度、阀位置或 加热元件的占空比。
西门子控制器家族产品
西门子控制器系列是一个完整的产品组合,包括从高性能可编程 逻辑控制器的书本型迷你控制器 LOGO! 到基于 PC 的控制器,无论 多么苛刻的要求,它都能满足要求 — 根据具体应用需求及预算, 灵活组合、定制(系列化的控制器家族产品满足你的不同应用及 需求)。
SIMATIC S7-1200 小型可编程控制器充分满足于中小型自动化的 系统需求。在研发过程中充分考虑了系统、控制器、人机界面和 软件的无缝整合和高效协调的需求。SIMATIC S7-1200 系列的问 世,标志着西门子在原有产品系列基础上拓展了产品版图,代表 了未来小型可编程控制器的发展方向,西门子也将一如既往开拓 创新,引领自动化潮流。
速度和位置控制 PLCopen 运动 控制指令 • PLCopen 是一个国际性的运
动控制标准 • 支持绝对,相对运动和在线
改变速度的运动 • 支持找原点和爬坡控制 • 用于步进或伺服电机的简单
启动和试运行 • 提供在线检测
PID 控制
SIMATIC S7-1200 控制器中提供 了多达 16 个带自动调节功能的 PID 控制回路,用于简单的闭环 过程控制。
• 正交相位
脉冲输出 存储卡 实时时钟保持时间 PROFINET 实数数学运算执行速度 布尔运算执行速度
DC/DC/DC,AC/DC/RLY,DC/DC/RLY 90 x 100 x 75
• 25 KB • 1 MB • 2 KB
• 6 点输入/4 点输出 • 2 路输入
• 8 点输入/6 点输出 • 2 路输入
1 个以太网通信端口
18μs/指令
0.1μs/指令
110 x 100 x 75
• 50 KB • 2 MB • 2 KB
• 14 点输入/10 点输出 • 2 路输入
任何具备串行接口的设备都能够被连接,例如驱动器,打印机, 条形码阅读器,调制解调器等。
点对点连接
CM 1241
以下设备可被连接: • PG 编程设备和计算机(通过超 5 类线)
SIMATIC S7-1200
PG
PROFINET
PG 与 SIMATIC S7-1200 CPU 的连接 8
SIMATIC S7-1200
可扩展的灵活设计
信号模块
多达 8 个信号模块可连接到扩 展能力最高的 CPU,以支持更 多的数字量和模拟量输入/输出 信号连接。
信号板
一块信号板可以连接至所有的 CPU,由此您可以通过向控制器 添加数字量或模拟量输入/输出 通道来量身订制 CPU,而不必 改变其体积。SIMATIC S7-1200 控制器的模块化设计允许您按 照实际的应用需求准确地设计 控制器系统。
7
通讯
SIMATIC S7-1200 配备了不同的通讯机制: • 集成的 PROFINET 接口 • 通过通讯模块实现点对点连接
PROFINET 接口
• SIMATIC HMI 精简系列面板:
精简系列面板 PROFINET
SIMATIC S7-1200
精简系列面板与 SIMATIC S7-1200 CPU 的连接 更多 SIMATIC S7-1200 控制器
集成的 PROFINET 接口允许与以下设备通讯: • 编程设备 • HMI 设备 • 其它 SIMATIC 控制器
支持以下协议: • TCP/IP • ISO-on-TCP • S7 通讯(服务器端)
组网简单
SIMATIC S7-1200 通讯接口由一个抗干扰的 RJ45 连接器组成。该连 接器具有自动交叉网线(auto-cross-over)功能,支持最多 16 个以太 网连接,数据传输速率达 10/100 Mbit/s。为了使布线最少并提供最 大的组网灵活性,可以将紧凑型交换机模块 CSM 1277 和 SIMATIC S7-1200 一起使用,以便轻松组建成一个统一或混合的网络(具有线 型、树型或星型的拓扑结构)。CSM 1277 是一个 4 端口的非托管交 换机,用户可以通过它将 SIMATIC S7-1200 连接到最多 3 个附加设 备。除此之外,如果将 SIMATIC S7-1200 和 SIMATIC NET 工业无线 局域网组件一起使用,您还可以构建一个全新的组网规模。
S7-1200 可编程序控制器
产品样本
3
产品样本
SIMATIC S7-1200
河南四方恒业科技有限公司
33
S7-1200 可编程序控制器
产品样本
技术综述
4
S7-1200 CPU
CPU 1211C
10
CPU 1212C
12
CPU 1214C
14
输入/输出扩展模块
SB 1223 数字量输入/输出模块(信号板)
CSM 1277 以太网交换机 SIMATIC S7-1200
精简系列面板
PROFINET
通过 CSM 1277 工业以太网交换机的多设备的连接
通过通讯模块实现点对点通讯
通讯模块允许通过点对点连接的通讯。应用 RS232 和 RS485 物理 传输介质。数据传输在 CPU 自由端口模式下执行。用户定义的、位元 导向的通讯协议被应用(例如 ASCII 协议,USS,或 MODBUS RTU)。
信号板(SM) CPU
信号模块(SM)
通信模块(CM)
I/O 端子连接器 PROFINET 接口 4
S7-1200 外形及安装
安装简单方便
所有的 SIMATIC S7-1200 硬件都具有内置安装夹,能够方便地安 装在一个标准的 35 mm DIN 导轨上。这些内置的安装夹可以咬合 到某个伸出位置,以便在需要进行背板悬挂安装时提供安装孔。 SIMATIC S7-1200 硬件可进行竖直安装或水平安装。这些特性为用 户安装 PLC 提供了最大的灵活性,同时也使得 SIMATIC S7-1200 成为众多应用场合的理想选择。
打印设备
调制解调器
驱动器
通过 CM1241 在编程接口模式下的点对点连接
中央处理器单元(CPU)
常规规范
型号 外观
CPU 1211C
CPU 1212C
CPU 1214C
3 CPUs 物理尺寸(mm) 用户存储器 • 工作存储器 • 装载存储器 • 保持性存储器 本体集成 I/O • 数字量 • 模拟量 过程映像大小 位存储器(M) 信号模块扩展 信号板 最大本地 I/O - 数字量 最大本地 I/O - 模拟量 通信模块 高速计数器 • 单相
16
SM 1221 数字量输入模块
16
SM 1222 数字量输出模块
17
SM 1223 数字量输入/输出模块
18
SB 1332 模拟量输出模块(信号板)
19
SM 1231 模拟量输入模块
19
SM 1232 模拟量输出模块
20
SM 1234 模拟量输入/输出模块
20
电源模块 PM 1207
21
输入仿真器 SIM 1274
低端独立自动化系统中简 单的开关控制解决方案使 用的智能逻辑控制器
I/O 能力,程序大小,指令速度,通讯能力,…
SIMATIC S7-1200
SIMATIC S7-1200 具有集成 PROFINET 接口、强大的集成工艺功能 和灵活的可扩展性等特点,为各种工艺任务提供了简单的通讯和
有效的解决方案,尤其满足多种应用中完全不同的自动化需求。
21
通讯模块
CM 1241 通讯模块
22
CSM 1277 紧凑型交换机模块
23
SIMATIC HMI 精简系列面板
24
工程组态软件 STEP 7 — 中央处理单元接线图
26
— 扩展模块接线图
28
附录 2 — 通用技术规范
30
附录 3 — 订货数据
31
3
SIMATIC S7-1200 技术综述