系统操作维护文档1、Cluster的操作l 查看Cluster状态:使用hastat命令来查看# hostnameChina168-1# hastatGetting Information from all the nodes ......HIGH A V AILABILITY CONFIGURATION AND STATUS------------------------------------------LISTOF NODES CONFIGURED IN <China168> CLUSTERChina168-1 China168-2CURRENT MEMBERS OF THE CLUSTERChina168-1 is a cluster memberChina168-2 is a cluster memberCONFIGURATION STATE OF THE CLUSTERConfiguration State on China168-1: StableConfiguration State on China168-2: StableUPTIME OF NODES IN THE CLUSTERuptime of China168-1: 3:17pm up 1 day(s), 2:30, 3 users, load average: 0.13, 0.41, 0.50uptime of China168-2: 3:18pm up 1 day(s), 2:30, 3 users, load average: 0.08, 0.18, 0.24LOGICAL HOSTS MASTERED BY THE CLUSTER MEMBERS Logical Hosts Mastered on China168-1:NoneLogical Hosts for which China168-1 is Backup Node:NoneLogical Hosts Mastered on China168-2:NoneLogical Hosts for which China168-2 is Backup Node:NoneLOGICAL HOSTS IN MAINTENANCE STA TENoneSTA TUS OF PRIV ATE NETS IN THE CLUSTERStatus of Interconnects on China168-1:interconnect0: selectedinterconnect1: upStatus of private nets on China168-1:To China168-1 - UPTo China168-2 - UPStatus of Interconnects on China168-2:interconnect0: selected interconnect1: upStatus of private nets on China168-2:To China168-1 - UPTo China168-2 - UPSTA TUS OF PUBLIC NETS IN THE CLUSTERStatus of Public Network On China168-1:bkggrp r_adp status fo_time live_adpnafo0 hme0:hme1 OK 89755 hme1Status of Public Network On China168-2:bkggrp r_adp status fo_time live_adpnafo0 hme0:hme1 OK NEVER hme0…………………….我们可以看到上面红字的部分,它表示现在两台机器都是Cluster的成员。
SUN服务器磁带机数据库安装及其日常维护介绍材料

SUN硬件系统安装及管理维护手册目录一,Sun X4600服务器安装及维护 (3)1.1 X4600服务器硬件设置及维护管理 (3)1.2在X4600服务器上安装RHEL5.2操作系统 (7)二,Sun STK6140存储阵列安装及维护 (16)2.1 STK6140磁盘阵列硬件安装 (16)2.2 STK6140磁盘阵列管理与维护设置 (17)三,SUN SL48自动磁带库安装及维护 (25)3.1 SL48磁带库安装 (25)3.2 SL48维护管理设定 (27)四,Oracle 10g数据库安装 (28)4.1 安装基本信息 (28)4.2 安装前准备工作 (28)4.3 安装ORACLE 10G (10.2.0.1版本)数据库系统 (31)五,VCS双机热备软件安装及日常维护 (41)5.1 VCS 5.0双机热备软件安装 (41)5.2 VCS软件日常管理 (43)六,NETBACKUP自动备份软件安装及日常维护 (48)6.1 NETBACKUP备份软件安装 (48)6.2 Netbackup软件日常管理 (55)七,系统开关机流程 (57)7.1系统关机流程 (57)7.2 系统开机流程 (57)一Sun X4600服务器安装及维护1.1 X4600服务器硬件设置及维护管理SUN X4600服务器背后示意图:服务器连接方式:SUN X4600服务器有二种人机界面连接方式:➢显示器/键盘/鼠标管理➢ILOM管理(有串行口和网络口两种管理途径)各接口部位如上图所示,对于支持无显示器操作的操作系统,键盘、鼠标和视频显示器是可选件。
安装在机柜中的服务器,可以采用网络管理口进行远程管理。
网络管理IP设置:如上图所示,标注"NET 0" 至"NET 3" 的连接器为10/100/1000 千兆位以太网端口。
标注"NET MGT" (网络管理)的端口为10/100 以太网端口,用于将系统连接到一个管理网络。
SUN日常维护手册

SUN日常维护手册Sun日常维护手册(v 20131108)版本说明目录目录版本说明 (2)一、机房环境检查 (6)1.机房温度 (6)2.机房湿度 (6)3.机房洁净度 (6)二、主机硬件运行情况检查 (7)1.主机状态灯检查 (7)1.1 SUN SPARC Server Front Panel LEDs (7) 1.2 SUN SPARC Server Rear Panel LEDs (8)1.3 SUN SPARC Server Disk Drive LEDs (9)2、主机硬件配置及运行状态检查 (9)2.1 CPU配置检查 (9)2.2 内存配置检查 (10)2.3 内置硬盘配置检查 (12)2.4 网卡配置检查 (13)2.5 风扇情况检查 (15)2.6 系统日志检查 (16)三、存储设备运行情况检查 (17)1.Sun StorEdge A1000系列 (17)2.Sun StorEdge 3510系列 (17) 3.Sun StorageTek 6140系列 (18) 四、Solaris操作系统运行状态检查 (21) 1.操作系统版本 (21)2.文件系统类型 (22)2.1 UFS (Unix File system) (23)2.2 VXFS (Veritas File System) (23) 2.3 ZFS (Zettabyte File System) (24) 3.卷管理和数据镜像 (25)3.1 SVM卷管理 (25)3.2 VXVM卷管理 (27)3.3 ZFS卷管理 (30)4.多路径检查 (30)4.1 多路径配置文件 (30)4.2 多路径状态检查 (31)5.系统性能运行检查 (31)5.1 CPU使用情况检查 (31)5.2 内存使用情况检查 (32)5.3 I/O使用情况检查 (34)五、双机Cluster运行状态检查 (35)1. Sun Cluster (35)2. Veritas Cluster (39)六、故障诊断信息收集 (42) 1.Power-On Self Test (POST) (42) 2.Sun Explorer (43)七、日常维护周期策略 (43)1.日维护内容 (43)1.1 机房环境 (43)1.2 硬件状态 (46)1.3 系统状态 (47)1.4 集群状态 (49)1.5 性能和安全 (49)1.6 磁盘阵列存储状态 (51)2.周维护内容 (52)2.1 机房环境 (52)2.2 硬件状态 (52)2.3 系统状态 (53)2.4 集群状态 (53)2.5 性能和安全 (53)2.6 补丁 (53)2.7 磁盘阵列存储状态 (53)3.月维护内容 (55)3.1 机房环境 (55)3.2 硬件状态 (55)3.3 系统状态 (55)3.4 集群状态 (55)3.5 性能和安全 (55)3.6 补丁 (55)3.7 磁盘阵列存储状态 (56)八、附录 (56)8.1. ILOM巡检指导v1.0 (56)8.2. XSCF 巡检操作指导v1.0 (58)8.2 SC 巡检操作指导v1.0 (64)一、机房环境检查机房的温度,湿度和洁净度是否合理,将会直接影响到设备的正常运作,如果机房的温度过高,湿度过于干燥,灰尘过多的话将会直接影响设备的使用寿命,因此平时对机房的健康和检查也是必不可少的。
SUN平台系统维护

Fault
Activity Disk fault Over-temp
Power fault
硬件故障指示灯
power
(cont.)
Hardware Cycling or running failure normally
off on off off off on off on/off on off System has no power Failure mode Failure mode System is hung, either in POST/OpenBoot
第29页
Sun Fire480000的配置和维护
Use DHCP or static network settings? [DHCP]: static // 设置成静态计算机。
第25页
Sun Fire4800的配置和维护
Hostname [ha132]: 4800-sc0 //控制板的逻辑主机名。 // 控制板
IP Address [192.9.160.132]: 192.168.0.1 使用的IP地址 。 Netmask [255.255.255.0]: ↙ Gateway [192.9.160.254]: 0.0.0.0 DNS Domain []: Primary DNS Server []: Secondary DNS Server []: ↙ ↙
系统硬件资源的分配:
ACLs ----
//系统硬件资源的划分(这里只分配一个domain)
//domain
ACL for domain A [ SB0 SB2 SB4 IB6 IB8 ]: ↙ A 可以利用所有硬件
ACL for domain B [ SB0 SB2 SB4 IB6 IB8 ]: 不能利用所有硬件
SUN2000-(50KTL) 用户手册

SUN2000-(50KTL,50KTL-C1)用户手册文档版本 Draft A 发布日期2016-01-30华为技术有限公司版权所有© 华为技术有限公司2016。
保留一切权利。
非经本公司书面许可,任何单位和个人不得擅自摘抄、复制本文档内容的部分或全部,并不得以任何形式传播。
商标声明和其他华为商标均为华为技术有限公司的商标。
本文档提及的其他所有商标或注册商标,由各自的所有人拥有。
注意您购买的产品、服务或特性等应受华为公司商业合同和条款的约束,本文档中描述的全部或部分产品、服务或特性可能不在您的购买或使用范围之内。
除非合同另有约定,华为公司对本文档内容不做任何明示或默示的声明或保证。
由于产品版本升级或其他原因,本文档内容会不定期进行更新。
除非另有约定,本文档仅作为使用指导,本文档中的所有陈述、信息和建议不构成任何明示或暗示的担保。
华为技术有限公司地址:深圳市龙岗区坂田华为总部办公楼邮编:518129网址:客户服务邮箱:support@客户服务电话:4008302118前言概述本文档主要介绍了SUN2000-50KTL/50KTL-C1(后文简称SUN2000)的安装、电气连接、调试、维护和故障处理的方法。
请在安装、使用逆变器之前,认真阅读本手册,了解安全信息并熟悉逆变器的功能和特点。
读者对象本手册适用于光伏电站操作人员及具备相应资质的电气技术人员。
符号约定在本文中可能出现下列标志,它们所代表的含义如下。
修改记录修改记录累积了每次文档更新的说明。
最新版本的文档包含以前所有文档版本的更新内容。
文档版本Draft A (2016-01-30)试验局版本。
目录前言 (ii)1 安全注意事项 (1)2 产品介绍 (3)2.1 产品简介 (3)2.2 外观说明 (4)2.3 标签说明 (8)2.4 工作原理 (10)3 逆变器存储 (12)4 系统安装 (13)4.1 安装前检查 (13)4.2 准备安装工具 (13)4.3 挂墙安装 (17)4.3.1 选择安装位置 (17)4.3.2 搬运逆变器 (22)4.3.3 安装工程安装件 (23)4.3.4 安装逆变器 (26)4.4 支架安装 (29)4.4.1 选择安装位置 (29)4.4.2 搬运逆变器 (32)4.4.3 安装工程安装件 (32)4.4.4 安装逆变器 (34)5 电气连接 (35)5.1 开维护腔门 (35)5.2 连接保护地线(PE) (36)5.3 连接交流输出线 (38)5.4 连接直流输入线 (42)5.5 连接通信线 (48)5.5.1 通信方式说明 (48)5.5.2 连接RS485通信线 (49)5.6 关维护腔门 (55)6 系统调试 (57)6.1 上电前检查 (57)6.2 系统上电 (57)6.3 系统下电 (58)7 系统维护 (59)7.1 日常维护 (59)7.2 故障处理 (60)8 逆变器处置 (65)8.1 拆卸逆变器 (65)8.2 包装逆变器 (65)8.3 报废逆变器 (65)9 技术数据 (66)A 缩略语 (69)1 安全注意事项人员要求●所有针对SUN2000的操作必须由训练有素的专业电气技术人员进行。
太阳能发电系统维护手册精品

太阳能光伏发电系统运行维护手册北京XXXX有限公司2011年8月10日一、使用注意事项为避免危险,在运行、维修和检查之前,请您详细阅读本使用说明书,本文中记载的注意事项和粘贴在设备上的注意标记,请您一定要遵守。
本使用说明书中用“警告”和“注意”标记作为安全方面的注意事项。
当错误使用时,使用者可能有死亡或负重伤的情况。
发生轻伤或设备损坏情况的概率高。
当错误使用时,使用者负重伤的可能性小,有受伤害的危险情况和只是发生设备损坏的情况。
再者,在上述 “注意”中记载的事故或状况,有时也关联着大的事故。
因为记载的内容都是重要的,请务必遵守。
除在上述的符号外,也请注意下述的表示符号。
表示不应做的事。
表示非做不可的事。
1.1安全注意事项警告注意二、用户日常检查及维护日常检查时每月进行一次外观检查。
检查项目如表所示,当认为异常时,可向专业技术人员求助。
2.1用户维护参考三、系统的操作顺序3.1运行的操作顺序(运行前的准备工作)确认汇流箱、逆变器所有的开关断开后,连接蓄电池。
●请注意极性,不要短路,触电。
逆变器、蓄电池等开关应置于“ON”位置。
以后这些开关运行中严禁断开。
除长期停用以外,正常时应放在ON位置上。
(运行顺序)●运行应在太阳能电池发电充足的状态下进行。
①闭合交流系统并网输出开关;②闭合蓄电池开关;(只适用于带蓄电池的系统)③在显示单元上,请确认A01没有点亮;④闭合太阳能电池输入开关,逆变器单元的运行开关置于“运行”位置;⑤此状态经过20秒,运行开关的绿色LED和显示单元的“运行”指示灯点亮,则设备开始运行⑥闭合自立输出开关(只针对LINE BACK ∑ PLUS设备,市电停电后,此端口才有电压输出);⑦在并网运行时,请对下列情况进行确认:●不应进行外部停止操作。
●太阳能电池应正处于发电充足状态。
(直流电压在启动电压以上)●在显示单元上应不出现异常的表示。
3.2 停止顺序补充:在对应急配电回路线路维修时,请切断系统应急输出。
SUN系统操作维护文档 _4

mount到操作系统中,因此在操作系统中是看不到它的,
它保留着整个系统的完整备份。当工作中的硬盘出现故障时,可以使用第二块硬盘启动
系统。有关这里如何操作,详见系统维护文档。
China168-1机器上的两块硬盘的设备名分别为
c0t0d0和
c0t2d0,China168-1机器上的两
inet 204.152.65.1 netmask fffffff0
scid0:1: flags=10080c1<UP,RUNNING,NOARP,PRIVATE,IPv4> mtu 16321 index 3
inet 204.152.65.33 netmask fffffff0
scid1: flags=10080c1<UP,RUNNING,NOARP,PRIVATE,IPv4> mtu 16321 index 4
# hostname
China168-1
# ifconfig -a
lo0: flags=1000849<UP,LOOPBACK,RUNNING,MULTICAST,IPv4> mtu 8232 index 1
inet 127.0.0.1 netmask ff000000
scid0: flags=10080c1<UP,RUNNING,NOARP,PRIVATE,IPv4> mtu 16321 index 3
整个磁盘的管理可以理解为一个分层的结构,就象
OSI的
7层网络模型一样,每一层只
使用它的下一层给它提供的接口,而不去理会更底层的信息,同时向上一层提供本层的
接口。最底层是物理上的
6块磁盘,最上层是划分出来的卷。其模型见下图:
Sun StorEdge 3510 FC 阵列安装、操作和维护手册说明书

Sun StorEdge 3000 系列安装、操作和维护手册Sun StorEdge 3510 FC 阵列Sun Microsystems, Inc.4150 Network CircleSanta Clara, CA 95054 U.S.A.650-960-1300部件号 817-2760-102003 年 3 月,修订版 A请将对本文档的意见发送到:*******************版权所有 © 2002-2003 Dot Hill Systems Corporation, 6305 El Camino Real, Carlsbad, California 92009, USA.保留所有权利。
Sun Microsystems, Inc. 和 Dot Hill Corporation 可能拥有与本产品或文档中涉及的技术相关的知识产权。
具体来说(且不仅限于此),这些知识产权包括 /patents 所列出的美国专利中的一项或多项,以及在美国或其他国家(地区)申请的一项或多项补充专利或未决专利。
本产品或文档按照限制其使用、复制、分发和反编译的许可证进行分发。
本产品或文档的任何部分,未经 Sun 及其许可方(如果有)的事先书面授权,不得以任何形式或任何手段加以复制。
第三方软件由 Sun 供应商提供版权及许可授权。
本产品的某些部分来源于 Berkeley BSD 系统,已获得 University of California 的许可。
UNIX 是在美国和其他国家(地区)的注册商标,已通过 X/Open Company, Ltd. 获得独家许可。
Sun、Sun Microsystems、Sun 标志、Sun StorEdge、AnswerBook2、, 和 Solaris 是 Sun Microsystems, Inc. 在美国和其他国家(地区)的商标或注册商标。
美国政府权利 ó 商业使用。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
现场工程师SUN设备维护手册更新日期:2002 年 6 月18 日版本:2.0目录技术部分1系统维护 (1)1.1 系统日常维护操作 (1)1.2 操作命令示例 (3)2常用SUN企业级服务器介绍 (12)2.1 E250服务器 (12)2.2 E450服务器 (12)2.3 E3000/E3500服务器 (13)2.4 E4000/E4500服务器 (13)2.5 E5000/E5500服务器 (13)2.6 E6000/E6500服务器 (14)3SUN系统管理员常用概念/命令 (15)3.1 SUN服务器体系结构 (15)3.2 系统自检(POST)/O PENBOOT(P ROM)/IDPROM/VNRAM常用命令 (19)3.3 S OLARIS 操作系统的安装: (22)3.4 应用软件常用安装/删除命令(ADD/DELETE SOFTWARE) (23)3.5 补丁管理命令P ATCH (24)3.6 操作系统启动过程及运行级别 (24)3.7 操作系统启动/关闭时运行的脚本命令 (26)3.8 硬盘分区及格式化(DISK PARTITION AND FORMAT ) (27)3.9 S OLARIS 文件系统管理(UNIX FILE SYSTEM ) (28)3.10 系统备份/恢复(BACKUP AND RESTORE ) (29)3.11 网络管理(NETWORK) (31)3.12 路由服务器: (34)3.13 域名服务器(DNS) (34)3.14 NIS服务器 (35)3.15 NFS文件系统(NFS FILE SYSTEM ) (37)3.16 并行打印机/显示器管理(P ARALLEL P ORT P RINTER ) (38)3.17 用户管理USER ACCOUNT (39)3.18 系统资源限制(如:同时打开文件数、文件大小、CPU利用限制...) (41)3.19 系统性能监控和管理 (41)3.20 常用UNIX命令集锦(C OMMONLY USED UNIX COMMANDS ) (41)4数据保护 (43)4.1 常用概念 (43)4.1.1存储(Storage): (43)4.1.2备份(Backup): (43)4.1.3恢复(Restore): (43)4.1.4归档(Archive): (44)4.2 存储介质操作 (45)4.2.1介质环境适应(Media Acclimation) (45)4.2.2介质操作环境(Operating Environment) (45)4.2.3介质存储环境(Storage Environment) (45)4.3 注意事项: (45)4.3.1要求作到 (45)4.3.2要求避免 (46)5机房场地规划要求 (47)5.1 环境部分 (47)5.2 电力部分 (47)5.3 空调照明消防部分 (49)5.4 存储要求 (49)技术部分1系统维护1.1系统日常维护操作机器S/N 日期:20 年月日步骤检测内容命令功能是否正常1 状态灯观察系统面板状态灯,是否有橙色维修报警灯亮?是□否□2 确定系统基本信息# uname –a Displays system information 是□否□3 # last Tells who was or still is on thesystem 是□否□4 系统低层信息诊断# /usr/sbin/prtconf –vp Show system configuration details 是□否□5 # psrinfo | wc –l Display number of processors是否有CPU处于离线(offline)状态?CPU是否与实际相符? 是□否□6 # prtconf | grep "Memory size" Display Memory SizeMEM是否与实际相符? 是□否□7 # /usr/platform/sun4u/sbin/prtdiag -v |more prtdiag displays systemconfiguration and diagnosticinformation on sun4u and sun4dsystems. The diagnosticinformation lists any failed FieldReplaceable Units (FRUs) in thesystem.是否有警告/错误? 是□否□8 系统日志分析# vi /var/adm/messages Check error/WARNING messages是否有警告/错误? 是□否□9 文件系统/磁盘分析# df –k Check number of free disk blocksand files是否有文件系统使用率大于90%?是否所有文件系统都已安装(mount)?是□否□10 # swap –s Print summary information abouttotal swap spaceusage and availability交换区是否用完? 是□否□11 # format disk partitioning and maintenanceutility硬盘数是否与实际相符? 是□否□12 # prtvtoc /dev/rdsk/c?t?d?s2 Disk geometry and partitioning info 是□否□13 # vxdisk list List detailed disk information onthe specified disks.是否有vm disk* 处于error状态? 是□否□14 # vxdg list List the content of disk group是否有磁盘组(disk group)不见? 是□否□15 # vxprint -ht display records from the VolumeManager configuration and status 是□否□16 # luxadm probe Finds and displays informationabout all attached A5x00subsystems, including the logicalpathname, the WWNs, andenclosure names. Thissubcommand warns the user if itfinds different SENAs with thesame enclosure names. 是□否□17 #mt –f /dev/rmt/0 Check the tape driver status 是□否□18 网络分析# ifconfig -a configure network interfaceparameters displays the currentconfiguration 是□否□19 # /etc/opt/SUNWconn/bin/nettr -stats 0device=qfe Checked Trunking interface To getbasic performance data是□否□20 # ndd /dev/ip \? Shows IP variables in the kernel 是□否□21 # netstat -i 5 5 在errs 栏是否有明显大量错误?在colls 栏是否有明显大量冲突? 是□否□22 # netstat -a Displays number active establishedconnections to the localhost是否有异常的端口状态? 是□否□23 # netstat –r Show network route table 是□否□24 # traceroute <ipaddress> Follow the route to the ip address 是□否□25 性能分析# /usr/ucb/ps -aux | more Displays CPU % usage for eachprocess in ascending order 是□否□26 # sar –u 5 20 Report CPUUtilization, %usr, %sys, %wio, %idle; portion of time running in usermode, running in system mode, idlewith some process waiting forblock I/O, and otherwise idle. 是□否□27 # iostat -xn 20 5 Command to display drivesstatistics系统是否I/O繁忙(%b>30)? 是□否□28 # vmstat 10 Displays summary of what thesystem is doing every 10 seconds系统是否内存不够(sr栏>200)?系统是否CPU资源不够(id<10)? 是□否□1.2操作命令示例edis# netstat -i 5input hme0 output input (Total) outputpackets errs packets errs colls packets errs packets errs colls 38646105 20969 9013311 0 0 56861879 20969 27229085 0 0 23 0 1 0 0 75 0 53 0 025 0 2 0 0 25 0 2 0 030 0 3 0 0 68 0 41 0 037 0 44 0 0 80 0 87 0 022 0 2 0 0 34 0 14 0 019 0 2 0 0 50 0 33 0 029 0 3 0 0 75 0 49 0 017 0 2 0 0 50 0 35 0 013 0 2 0 0 23 0 12 0 029 0 2 0 0 29 0 2 0 036 0 2 0 0 36 0 2 0 0 edis# netstat -a |moreUDPLocal Address Remote Address State-------------------- -------------------- -------*.sunrpc Idle*.* Unbound*.32771 Idle*.name Idle*.biff Idle*.talk Idle*.time Idle*.echo Idle*.discard Idle*.daytime Idle*.chargen Idle*.32775 Idle*.32776 Idle*.32777 Idle*.32778 Idle*.32779 Idle*.32780 Idle*.32781 Idle*.32784 Idle*.lockd Idle*.syslog Idle*.32791 Idle*.177 Idle*.32792 Idle*.32793 Idle*.161 Idle*.32797 Idle*.32798 Idle*.32796 Idle*.* Unbound*.6500 Idle*.camudp Idle*.162 Idle*.33050 Idle*.33051 Idle*.6665 Idle*.* UnboundTCPLocal Address Remote Address Swind Send-Q Rwind Recv-Q State -------------------- -------------------- ----- ------ ----- ------ ------- *.* *.* 0 0 0 0 IDLE*.sunrpc *.* 0 0 0 0 LISTEN *.* *.* 0 0 0 0 IDLE*.ftp *.* 0 0 0 0 LISTEN *.telnet *.* 0 0 0 0 LISTEN *.shell *.* 0 0 0 0 LISTEN *.login *.* 0 0 0 0 LISTEN *.exec *.* 0 0 0 0 LISTEN *.uucp *.* 0 0 0 0 LISTEN *.finger *.* 0 0 0 0 LISTEN *.time *.* 0 0 0 0 LISTEN *.echo *.* 0 0 0 0 LISTEN *.discard *.* 0 0 0 0 LISTEN *.daytime *.* 0 0 0 0 LISTEN *.chargen *.* 0 0 0 0 LISTEN *.32771 *.* 0 0 0 0 LISTEN *.32772 *.* 0 0 0 0 LISTEN *.fs *.* 0 0 0 0 LISTEN *.32773 *.* 0 0 0 0 LISTEN *.printer *.* 0 0 0 0 LISTEN *.dtspc *.* 0 0 0 0 LISTEN *.xaudio *.* 0 0 0 0 LISTEN *.32774 *.* 0 0 0 0 LISTEN *.32775 *.* 0 0 0 0 LISTEN *.32776 *.* 0 0 0 0 LISTEN *.bpcd *.* 0 0 0 0 LISTEN *.vopied *.* 0 0 0 0 LISTEN *.bpjava-msvc *.* 0 0 0 0 LISTEN *.32777 *.* 0 0 0 0 LISTEN *.lockd *.* 0 0 0 0 LISTEN*.smtp *.* 0 0 0 0 LISTEN*.32778 *.* 0 0 0 0 LISTEN*.32779 *.* 0 0 0 0 LISTEN*.32780 *.* 0 0 0 0 LISTEN*.* *.* 0 0 0 0 IDLE*.* *.* 0 0 0 0 IDLE*.* *.* 0 0 0 0 IDLE*.32781 *.* 0 0 0 0 LISTEN*.32782 *.* 0 0 0 0 LISTEN*.32783 *.* 0 0 0 0 LISTEN*.* *.* 0 0 0 0 IDLE*.32784 *.* 0 0 0 0 LISTEN*.32785 *.* 0 0 0 0 LISTEN*.32786 *.* 0 0 0 0 LISTEN*.32787 *.* 0 0 0 0 LISTEN*.32788 *.* 0 0 0 0 LISTEN*.32789 *.* 0 0 0 0 LISTEN*.32790 *.* 0 0 0 0 LISTEN*.32791 *.* 0 0 0 0 LISTEN*.32792 *.* 0 0 0 0 LISTEN*.* *.* 0 0 0 0 IDLE*.* *.* 0 0 0 0 IDLE*.1521 *.* 0 0 0 0 LISTEN edis.2649 *.* 0 0 0 0 LISTEN edis.2651 *.* 0 0 0 0 LISTEN edis.32898 edis.2649 32768 0 32768 0 ESTABLISHED edis.2649 edis.32898 32768 0 32768 0 ESTABLISHED *.32899 *.* 0 0 0 0 LISTEN edis.32900 edis.2649 32768 0 32768 0 ESTABLISHEDedis# ifconfig -alo0: flags=849<UP,LOOPBACK,RUNNING,MULTICAST> mtu 8232inet 127.0.0.1 netmask ff000000hme0: flags=863<UP,BROADCAST,NOTRAILERS,RUNNING,MULTICAST> mtu 1500inet 10.243.1.95 netmask ffffff00 broadcast 10.243.1.255ether 8:0:20:ad:d6:47edis# ping gdmal001 is aliveedis# formatSearching for disks...doneAVAILABLE DISK SELECTIONS:0. c1t0d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>/sbus@3,0/QLGC,isp@0,10000/sd@0,01. c1t1d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>/sbus@3,0/QLGC,isp@0,10000/sd@1,02. c1t8d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>/sbus@3,0/QLGC,isp@0,10000/sd@8,03. c1t9d0 <SUN18G cyl 7506 alt 2 hd 19 sec 248>/sbus@3,0/QLGC,isp@0,10000/sd@9,0Specify disk (enter its number):edis# df -kFilesystem kbytes used avail capacity Mounted on/dev/dsk/c1t0d0s0 1018191 81032 876068 9% //dev/dsk/c1t0d0s4 2056211 511060 1483465 26% /usr/proc 0 0 0 0% /procfd 0 0 0 0% /dev/fd/dev/dsk/c1t0d0s5 1018191 204755 752345 22% /var/dev/dsk/c1t0d0s6 8068221 4316583 3670956 55% /export/dev/dsk/c1t0d0s3 1018191 216595 740505 23% /opt/dev/md/dsk/d0 51728612 21259039 29952287 42% /oracleswap 7391456 18608 7372848 1% /tmpedis# swap -lswapfile dev swaplo blocks free/dev/dsk/c1t0d0s1 32,1 16 4099424 4099408/dev/dsk/c1t0d0s7 32,7 16 4194272 4194272gdwww001# vxdisk listDEVICE TYPE DISK GROUP STATUSc0t0d0s2 sliced - - errorc0t0d0s7 simple c0t0d0s7 rootdg onlinec1t32d0s2 sliced - - errorc1t35d0s2 sliced oracle02 oracledg onlinec1t38d0s2 sliced oracle01 oracledg onlinec1t50d0s2 sliced oracle03 oracledg onlinec1t51d0s2 sliced oracle04 oracledg onlinegdwww001# vxdg listNAME STATE IDrootdg enabled 938671525.1025.gdqry001oracledg enabled 938675696.1064.gdqry001gdwww001# vxprint -htDisk group: rootdgDG NAME NCONFIG NLOG MINORS GROUP-IDDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEV NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEXPL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODE SD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODEdg rootdg default default 0 938671525.1025.gdqry001dm c0t0d0s7 c0t0d0s7 simple 1024 9748 -Disk group: oracledgDG NAME NCONFIG NLOG MINORS GROUP-IDDM NAME DEVICE TYPE PRIVLEN PUBLEN STATEV NAME USETYPE KSTATE STATE LENGTH READPOL PREFPLEXPL NAME VOLUME KSTATE STATE LENGTH LAYOUT NCOL/WID MODE SD NAME PLEX DISK DISKOFFS LENGTH [COL/]OFF DEVICE MODEdg oracledg default default 82000 938675696.1064.gdqry001dm oracle01 c1t38d0s2 sliced 4711 35363560 -dm oracle02 c1t35d0s2 sliced 4711 35363560 -dm oracle03 c1t50d0s2 sliced 4711 35363560 -dm oracle04 c1t51d0s2 sliced 4711 35363560 -v vol01 fsgen ENABLED ACTIVE 35363560 SELECT -pl vol01-02 vol01 ENABLED ACTIVE 35363560 CONCAT - RW sd oracle02-01 vol01-02 oracle02 0 35363560 0 c1t35d0 ENA pl vol01-01 vol01 ENABLED ACTIVE 35363560 CONCAT - RW sd oracle01-01 vol01-01 oracle01 0 35363560 0 c1t38d0 ENAv vol02 fsgen ENABLED ACTIVE 35363560 SELECT -pl vol02-01 vol02 ENABLED ACTIVE 35363560 CONCAT - RW sd oracle03-01 vol02-01 oracle03 0 35363560 0 c1t50d0 ENA pl vol02-02 vol02 ENABLED ACTIVE 35363560 CONCAT - RW sd oracle04-01 vol02-02 oracle04 0 35363560 0 c1t51d0 ENAedis# psrinfo -vStatus of processor 0 as of: 06/14/02 14:51:51Processor has been on-line since 04/26/02 15:08:40.The sparc processor operates at 400 MHz,and has a sparc floating point processor.Status of processor 1 as of: 06/14/02 14:51:51Processor has been on-line since 04/26/02 15:08:43.The sparc processor operates at 400 MHz,and has a sparc floating point processor.Status of processor 4 as of: 06/14/02 14:51:51Processor has been on-line since 04/26/02 15:08:43.The sparc processor operates at 400 MHz,and has a sparc floating point processor.Status of processor 5 as of: 06/14/02 14:51:51Processor has been on-line since 04/26/02 15:08:43.The sparc processor operates at 400 MHz,and has a sparc floating point processor.edis# /usr/platform/sun4u/sbin/prtdiag -v |moreSystem Configuration: Sun Microsystems sun4u 8-slot Sun Enterprise E4500/E5500 System clock frequency: 100 MHzMemory size: 4096Mb========================= CPUs =========================Run Ecache CPU CPUBrd CPU Module MHz MB Impl. Mask--- --- ------- ----- ------ ------ ----0 0 0 400 8.0 US-II 10.00 1 1 400 8.0 US-II 10.02 4 0 400 8.0 US-II 10.02 5 1 400 8.0 US-II 10.0========================= Memory =========================Intrlv. Intrlv.Brd Bank MB Status Condition Speed Factor With--- ----- ---- ------- ---------- ----- ------- -------0 0 1024 Active OK 60ns 4-way A0 1 1024 Active OK 60ns 4-way A2 0 1024 Active OK 60ns 4-way A2 1 1024 Active OK 60ns 4-way A========================= IO Cards =========================Bus FreqBrd Type MHz Slot Name Model--- ---- ---- ---- -------------------------------- ---------------------- 1 SBus 25 0 QLGC,isp/sd (block) QLGC,ISP1000U 1 SBus 25 3 SUNW,hme 1 SBus 25 3 SUNW,fas/sd (block) 1 SBus 25 13 SUNW,socal/sf (scsi-3) 501-3060 1 UPA 100 2 FFB, Double Buffered SUNW,501-4790No failures found in System===========================No System Faults found=============================================== Environmental Status ========================= Keyswitch position is in Secure ModeSystem Power Status: RedundantSystem LED Status: GREEN YELLOW GREENNormal ON OFF BLINKINGFans:-----Unit Status---- ------Rack OKKey OKAC OKSystem Temperatures (Celsius):------------------------------Brd State Current Min Max Trend--- ------- ------- --- --- -----0 OK 32 26 37 stable1 OK 37 36 41 stable2 OK 33 29 38 stableCLK OK 28 25 30 stablePower Supplies:---------------Supply Status--------- ------0 OK1 OK2 OK3 OKPPS OKSystem 3.3v OKSystem 5.0v OKPeripheral 5.0v OKPeripheral 12v OKAuxilary 5.0v OKPeripheral 5.0v precharge OKPeripheral 12v precharge OKSystem 3.3v precharge OKSystem 5.0v precharge OKAC Power OK========================= HW Revisions =========================ASIC Revisions:---------------Brd FHC AC SBus0 SBus1 PCI0 PCI1 FEPS Board Type Attributes--- --- -- ----- ----- ---- ---- ---- ---------- ----------0 1 5 CPU 100MHz Capable1 1 5 1 22 UPA-SBus-SOC+ 100MHz Capable2 1 5 CPU 100MHz CapableBoard 1 FFB Hardware Configuration:-----------------------------------Board rev: 2FBC version: 0x3241906dDAC: Brooktree 9070, version 13DRAM: Mitsubishi 130b, version 2System Board PROM revisions:----------------------------Board 0: OBP 3.2.28 2000/12/20 12:24 POST 3.9.28 2000/12/20 12:29 Board 1: FCODE 1.8.28 2000/12/20 12:22 iPOST 3.4.28 2000/12/20 12:28 Board 2: OBP 3.2.28 2000/12/20 12:24 POST 3.9.28 2000/12/20 12:29edis# vmstat 5 5procs memory page disk faults cpur b w swap free re mf pi po fr de sr m0 s0 s1 s7 in sy cs us sy id 0 0 0 7968 1688 0 16 0 4 4 0 0 1 1 1 0 621 685 290 0 1 99 0 0 0 7383872 74640 0 1 0 0 0 0 0 2 3 2 0 617 662 255 0 1 98 0 0 0 7383872 74640 0 0 0 0 0 0 0 1 0 1 0 616 528 321 0 1 99 0 0 0 7383664 74512 0 291 0 0 0 0 0 1 2 1 0 621 3459 379 3 2 94 0 0 0 7383872 74640 0 0 0 0 0 0 0 1 0 1 0 615 533 336 0 1 99edis# iostat -xn 20 5extended device statisticsr/s w/s kr/s kw/s wait actv wsvc_t asvc_t %w %b device0.0 1.2 0.0 14.0 0.0 0.0 0.0 16.7 0 1 d00.0 0.8 0.0 6.3 0.0 0.1 4.1 63.2 0 0 c1t0d00.0 1.2 0.0 11.6 0.0 0.0 0.0 16.7 0 1 c1t1d00.0 0.0 0.0 1.3 0.0 0.0 0.6 17.9 0 0 c1t8d00.0 0.0 0.0 1.1 0.0 0.0 0.0 11.2 0 0 c1t9d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c0t6d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 edis:vold(pid249) extended device statisticsr/s w/s kr/s kw/s wait actv wsvc_t asvc_t %w %b device0.0 1.1 0.0 8.4 0.0 0.0 0.0 19.0 0 1 d00.0 0.1 0.0 0.4 0.0 0.0 0.0 8.7 0 0 c1t0d00.0 1.1 0.0 8.4 0.0 0.0 0.0 19.0 0 1 c1t1d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t8d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t9d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c0t6d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 edis:vold(pid249) extended device statisticsr/s w/s kr/s kw/s wait actv wsvc_t asvc_t %w %b device0.0 1.1 0.0 8.8 0.0 0.0 0.0 15.9 0 1 d00.0 1.0 0.0 7.8 0.0 0.1 0.0 58.4 0 1 c1t0d00.0 1.1 0.0 8.8 0.0 0.0 0.0 15.8 0 1 c1t1d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t8d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t9d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c0t6d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 edis:vold(pid249) extended device statisticsr/s w/s kr/s kw/s wait actv wsvc_t asvc_t %w %b device0.0 1.0 0.0 8.4 0.0 0.0 0.0 18.6 0 1 d00.0 0.0 0.0 0.1 0.0 0.0 0.0 13.1 0 0 c1t0d00.0 1.0 0.0 8.4 0.0 0.0 0.0 18.6 0 1 c1t1d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t8d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t9d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c0t6d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 edis:vold(pid249) extended device statisticsr/s w/s kr/s kw/s wait actv wsvc_t asvc_t %w %b device0.0 1.1 0.0 8.8 0.0 0.0 0.0 15.9 0 1 d00.0 0.5 0.0 3.5 0.0 0.0 0.0 24.3 0 0 c1t0d00.0 1.1 0.0 8.8 0.0 0.0 0.0 15.9 0 1 c1t1d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t8d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c1t9d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 c0t6d00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 edis:vold(pid249)% mt status/dev/rmt/0n: no tape loaded or drive offline% mt -f /dev/rmt/0n statusHP DDS-3 4MM DAT tape drive:sense key(0x6)= Unit Attention residual= 0 retries= 0file no= 0 block no= 0garden:/home/dyin 3 %2常用Sun企业级服务器介绍Sun企业级服务器的RAS特性(Reliablility,Availability,Serviceability):UltraSPARC微处理器“马力”强劲;Gigaplane系统互联,速度保证;可靠技术,易于更换出错部件。