xStack Storage 快速安装配置指导(win)090120
将系统装进内存

只要不对真实硬盘进行读写操作,硬盘灯绝不闪,上网时那叫一个流畅。。。没用过固态硬盘,但是从性能上讲内存硬盘绝对 要比固态硬盘强,这是不容置疑的,缺点就是每次启动都要加载磁盘镜像(约20秒),并且每次对系统盘的操作重启后就会 还原 如果你现在正闲的蛋疼,并且有大内存,最重要的是爱折腾,那你就赶紧试试把win7装到内存吧~~~ 所需软件下载 1.Winimage:用于制作磁盘镜像 下载地址://200910/WinImagePortable.rar 2.grub for dos:在内存上映射磁盘镜像以及引导内存系统 下载地址:/project/grub4dos/GRUB4DOS/grub4dos 0.4.4/grub4dos-0.4.4.zip 3.Firadisk驱动:识别grub映射的磁盘镜像 下载地址:/grub4dos/FiraDisk/firadisk-driver-0.0.1.16.zip 4.prosen大侠制作的 win7精简版7260ex下载地址(395mb):/file/f04f0a9259
windows文件夹控制在1g左右,原来四五个g的winsxs被减到了可怜的二十几兆。。。
系统睡眠后将硬盘拔掉再启动,只有虚拟硬盘运行,没有硬盘的声音了,整个世界都清净了。。。
安装内存win7和内存xp的过程大致相同,但是有几点需要注意的: 1. win7下安装firadisk虚拟磁盘驱动需要点击设备管理器后在操作里点击”添加过时硬件“ 2. 制作系统镜像前需要打开cmd,然后: bcdedit /set {default} osdevice boot bcdedit /set {default} device boot bcdedit /set {default} detecthal 1 这是因为Vista开始bootmgr引导程序和NTLDR有所不同,一旦发现磁盘大小,文件系统等发生改变,会导致启动时出现 winload.exe错误导致无法启动系统。以上命令就是解决这个问题的。
AMD RAID 安裝指南说明书

AMD RAID 安裝指南1. AMD BIOS RAID 安裝指南 (2)1.1 RAID 簡介 (2)1.2 RAID 組態預防措施 (4)1.3 傳統 RAID ROM 組態(適用於 AMD X470、B450、X370、B350及 A320 晶片組) (5)1.4 UEFI RAID 組態(適用於 AMD X399、X470、B450、X370、B350及 A320 晶片組) (11)2. AMD Windows RAID 安裝指南 (16)1. AMD BIOS RAID 安裝指南AMD BIOS RAID 安裝指南係在說明如何藉由使用板載FastBuild BIOS utility,在 BIOS 環境下設定 RAID 功能。
製作 SATA 驅動程式磁片後,按下<F2> 或 <Del>進入BIOS設定,然後依照支援光碟所含「使用手冊」的詳細說明進行,之後即可開始使用板載 RAID 選項 ROM 公用程式設定 RAID。
1.1 RAID 簡介「RAID」是「獨立磁碟容錯陣列」的縮寫,是一種將兩顆以上硬碟組成一個邏輯單元的方法。
為達到最佳效能,請在建立 RAID 磁碟組時,安裝相同型號與容量的硬碟。
RAID 0(資料等量分配)RAID 0 是一資料等量分配技術,可最佳化兩顆相同的硬碟,以讀寫平行、交錯式堆疊中的資料。
此作法將可使單一磁碟的資料傳輸速率加倍,同時兩硬碟還可作為單一磁碟機,以持續的資料傳輸速率運作,進而提升資料存取及儲存效能。
警告!儘管 RAID 0 功能可提升存取效能,但並未提供任何容錯機制。
若熱插拔任何 RAID 0 磁碟的硬碟,將導致資料損壞或遺失。
RAID 1(資料映射)RAID 1 為資料映射技術,可將一顆磁碟機的資料映像複製至第二顆磁碟機,並維持相同的資料映像。
由於正常運行的磁碟機包含另一顆磁碟機內完整的資料複本,因此,若有一顆磁碟機故障,磁碟陣列管理軟體就會將所有應用程式引導至正常運行的磁碟機,因而提供了資料保護功能,並增進整部系統的容錯機制。
Storage Center 操作系统版本 7 软件更新指南说明书

Storage Center 操作系统版本 7软件更新指南注、小心和警告注: “注”表示帮助您更好地使用该产品的重要信息。
小心: “小心”表示可能会损坏硬件或导致数据丢失,并告诉您如何避免此类问题。
警告: “警告”表示可能会导致财产损失、人身伤害甚至死亡。
版权所有© 2018 Dell Inc. 或其附属公司。
保留所有权利。
Dell、EMC 和其他商标均为 Dell Inc. 或其附属公司的商标。
其他商标均为其各自所有者的商标。
2018 - 11Rev. F关于本指南 (4)修订历史记录 (4)读者对象 (4)联系 Dell (4)相关出版物 (4)1 使用入门 (5)Storage Center 配置要求 (5)Storage Manager Client 要求 (5)Storage Center 更新 (6)软件更新类型 (6)决定更新应用方式 (7)验证主机的最佳做法 (7)添加或升级机柜 (7)2 更新 Storage Center 软件 (9)使用 Storage Manager 更新 Storage Center (9)重新平衡端口 (10)使用 Unisphere 更新 Storage Center 软件 (10)重新平衡端口 (11)更新 Storage Center 版本 6.6 软件 (11)重新平衡端口 (12)目录3关于本指南本指南介绍了 Storage Center 更新软件包的内容,并提供了使用 Dell Storage Manager 更新 Storage Center 软件和固件所需的说明。
修订历史记录文档编号:680-025-018读者对象负责更新 Storage Center 软件的存储管理员是本指南的读者对象。
读者对象应该具备一定的存储和联网概念的工作知识。
联系 DellDell 提供了几种联机和电话支持与服务选项。
可用的选项因国家/地区和产品而不同,某些服务在您所在的区域可能并不提供。
nas存储服务器搭建详细教程

nas存储服务器搭建详细教程一、介绍随着数字化时代的到来,个人和企业对于数据的存储需求不断增加。
因此,搭建一个高效可靠的存储服务器成为了一个重要的任务。
本文将详细介绍如何搭建NAS(Network Attached Storage)存储服务器,以满足您的数据存储需求。
二、选择硬件在搭建NAS存储服务器之前,首先需要选择合适的硬件设备。
以下是一些常用的硬件选择建议:1. 主机:选择一台具有足够处理能力和存储容量的计算机作为主机。
2. 硬盘:选择高容量、高性能的硬盘,可以使用RAID技术提高数据的冗余性和读写速度。
3. 网络接口卡:选择支持千兆以太网的网卡,以满足高速数据传输的需求。
三、安装操作系统在选择好硬件之后,需要进行操作系统的安装。
可以选择运行在Linux系统上的自由软件NAS系统,例如FreeNAS或OpenMediaVault。
以下是一个简单的操作系统安装流程:1. 下载所需的NAS操作系统镜像文件,并将其烧录到U盘或光盘中。
2. 启动存储服务器,从U盘或光盘启动,并按照安装程序的提示进行操作系统的安装。
3. 安装完成后,重启系统,并登录到操作系统。
四、配置网络和存储安装完成操作系统后,需要进行网络和存储的配置。
以下是一些配置过程的步骤:1. 网络配置:设置存储服务器的IP地址、网关和DNS服务器。
确保存储服务器与其他设备可以进行正常通信。
2. 存储配置:在操作系统中配置硬盘和RAID(如果需要)以及文件系统。
可以使用Web界面或命令行工具进行配置。
3. 共享文件夹:创建共享文件夹并设置权限,以便其他设备可以访问和存储数据。
五、数据备份和恢复策略为了确保数据的安全性和可靠性,需要制定合适的数据备份和恢复策略。
以下是一些建议:1. 定期备份:定期将存储服务器中的数据备份到外部存储设备或云存储中,以防止数据丢失。
2. 冗余存储:使用RAID等技术提高数据的冗余性,当硬盘损坏时可以进行数据恢复。
EverFocus X-Lite Windows快速安装指南说明书

X-Lite WindowsQuick Installation GuideCopyright © EverFocus Electronics Corp,Release Date:September 2015Version: v1.0.0Table of Contents1. X-Lite Install Guide (1)2. X-Lite Launch Window (6)2.1 Launch Window (6)3. X-Lite Log In & Initial Setup (7)3.1 X-Lite Log-In (7)3.2 Time Zone (9)3.3 Main Page Icon Description (11)1. X-Lite Install Guide.1)To install X Lite,double click on the ICON.2)The install wizard will launch and guide the user through the installationprocess.Figure13)Users will have to accept the terms and conditions of the End User LicenseAgreement to go to the next steps and install the software.Figure24)Check “Create a desktop icon” and click “Next”.Figure35)Select“Install”to run the install procedure for the software.Figure4Figure56)Once the install procedure is complete,the software will launch automaticallyby clicking on the“Finish”button.Figure6Figure7Figure8It is essential to set the correct“User Time Zone”2. X-Lite Launch Window.2.1 Launch WindowFigure 9is the launch window. Any functions being carried out by X Lite are run through this window. Closing this window will shut down X Lite and any functions being carried out at the time, including “Schedule Archive and Event Listener”.Figure9Refer to ing this button will launch X-Lite window. Up to three windows can be launched; each can run independent display functions.This button provides a visual display of Schedule Archive process.This button will launch an Event Listener window displaying event information without the need of running an X-Lite window all the time.3. X-Lite Log In & Initial Setup.3.1 X-Lite Log-In.Use this button to launch an X-Lite Window. The LOG IN screen will display as shown in Figure 10Figure10The default user name:adminThe default password:11111111Figure11Figure 11shows the default screen when an X-Lite window is launched. This window can be used to access various menu features of the software.3.2 Time ZoneIt is essential that the correct time zone is selected. Incorrect Time Zone settingwill affect accurate play back of data.Use the“settings” icon to gain access to “User Time Zone”. In“Setting”,select“User Setting” “User Time Zone”.Select the region the computer being used is located in,and then select“Apply”.Figure121234verify time is correct and apply settingsFigure13Figure14Select the correct region and confirm the time is correct before using APPLY.3.3 Main Page Icon DescriptionUsed to hide or display the side menu tree.Used to adjust aspect ratio for on screen cameras.Display date and time information for a device.Window display to full screen mode.Display camera menu option.To add an EverFocus device.Display live video.Play back video from a device.Download video or set up a schedule archive.Access software setting.Log out software.Change display theme between dark and light.Refresh the page.。
Dot Hill 服务器存储设备安装指南说明书

The person using these instructions must be qualified to service and install storage products.CAUTION: At least two people, optionally using a mechanical lift, are required to raise and move the enclosure into the rack.For detailed instructions and safety precautions, refer to the“Weight and placement guidelines” section of the Assure dSAN 6004 Series Setup Guide.Required tools•#2 Phillips screwdriver•Antistatic protection devicesRackmount bracket kit hardwareIMPORTANT: Do not install disk drive modules until the chassis is securely mounted in the rack.NOTE: During installation, apply torque specifications to screws as necessary.•Rear tie-down screws used to attach the back of the chassis to the rail: 10 in-lbs +/- 1.0 in-lbs.•All other rackmount bracket kit screws: 20 in-lbs +/- 2.0 in-lbs.1. Install railsNOTE: The two rail kit installation pictorials immediately following show the left and right rails viewed from thefront and looking rearward. An assembly and anexploded view is provided for each rail.Complete sub-steps 1–8 (following) to install the rails.1.Slide the rear rail insert (2) into the front rail sleeve (1).rail assembly to the rack and note which tapped holes inthe rear rail inserts align with the slotted holes on front railsleeves. If cage nuts are pre-installed, remove them.ing the measurements recorded in sub-step 2 above,select two or three #8-32 x 3/8 flathead Phillips screws(depending on your cabinet depth) to loosely attach therear rail insert to the front rail sleeve. You will tighten thescrews later.Code Part description QtyRails and brackets-Left rail (front sleeve with rear insert)1-ea.-Right rail (front sleeve with rear insert)1-ea.ScrewsA#8-32 x 3/8, FH, PLP2, SS6B#10-32 x 3/4, Truss, PLP, SS; orM5 x 10, PH, PLP2, SS; orM6 x 10, PH, PLP2, SS; or#12-24 x 3/8, PH, PLP, SS8C#10-32, Shoulder, Round hole mtg; or#10-32, Shoulder, Square hole mtg; or#10-32 x 0.319, FH100, PLP2, SS; orM5 x 8.4, FH, PLP2, SS; orM6 x 9.4, FH, PLP2, SS; or#12-24 x 0.354, FH100, PLP2, SS8D#10-32 x 0.217, FH100, PLP2, SS3NutsE#10-32, STL - Cage Nut; or#10-32, UNF - Clip Nut4Use fasteners that pertain to your rack type.4U56 storage enclosure(Enclosure bezel and disks are not installed) AssuredSAN 4U56Rackmount Bracket KitInstallationP/N 83-00006946-10-01Revision AFebruary 20162See Dot Hill’s customer resource center (CRC) web site foradditional information https://.。
istorage_doc

Istorage 服务器安装和使用指南1.准备服务器: (1)2.光盘启动服务器: (1)3.安装系统: (1)4.重启服务器: (3)5.注册服务器: (3)6.管理客户端的使用: (4)7.支持的1000M网卡: (12)8.支持的磁盘有关的硬件: (16)9.共享配置: (19)10.ShareRaid使用说明 (20)11.超级用户方式游戏更新: (22)12.超级客户端方式游戏更新: (26)13.建议服务器配置: (29)14.SAMBA,FTP使用说明: (29)15.服务器上的磁盘性能测试方法: (31)16.常见问题解决方法: (32)1. 准备服务器:准备一台服务器。
注意:安装程序会将系统盘上的所有分区删除,原来的数据会都丢失,有用的数据要先备份。
2. 光盘启动服务器:先下载安装光盘iso,然后刻录成一张光盘,将启动光盘放入光驱中,让光盘引导系统启动。
系统启动完毕,提示输入用户名和密码。
默认情况下用户名是root,密码是123,用户可以用passwd root命令修改密码3. 安装系统:1.执行par命令,看系统上的磁盘名称,如下图:关键看Name一项,不带数字的是表示磁盘,带数字的表示磁盘的分区,例如sda表示第一个磁盘,sda1表示第一个磁盘的第一个分区,sdb表示第二个磁盘,他没有分区。
2.如果要安装的系统盘上有分区,执行clear_disk 磁盘名,如要安装的是刚才看到的sda盘,就执行clear_disk sda,会看到类类似下图的结果:可以看到磁盘sda的分区都被删除了,这个时候要重启服务器。
然后在安装系统。
3.安装系统:安装命令介绍:install 磁盘名磁盘缓存大小(GB)根据你的实际情况,选择不同的安装参数,。
例如,●如果不需要磁盘缓存,安装命令为:install 磁盘名(如hda,sda) 0●如果将系统盘的所有剩余空间都作为磁盘缓存,安装命令为:install 磁盘名(如hda,sda) all。
win系统搭建nas完美方案

win系统搭建nas完美方案搭建NAS完美方案随着数字化时代的到来,数据的存储变得越来越重要。
对于许多人来说,个人云存储已经成为了一个不可或缺的工具。
在众多个人云存储方案中,搭建NAS(Network Attached Storage)是一种非常流行的选择。
在本文中,将介绍如何在Win系统上搭建NAS的完美方案。
一、硬件准备在搭建NAS之前,我们需要准备以下硬件设备:1. 一台运行Windows操作系统的台式电脑或服务器。
2. 至少两块硬盘,建议是高容量的硬盘(例如4TB或8TB)。
3. 一个网络交换机或路由器,用于将NAS与其他设备连接起来。
二、软件准备在进行硬件安装之前,我们需要准备以下软件:1. Windows操作系统安装光盘或镜像文件。
2. NAS管理软件,常用的有FreeNAS和OpenMediaVault等。
三、硬件安装与系统配置1. 将硬盘连接到计算机的SATA接口上。
2. 启动计算机,并按照Windows操作系统的安装向导进行安装。
3. 打开计算机的BIOS设置界面,确保硬盘被检测到并设置为启动设备。
4. 在Windows操作系统安装完成之后,检查硬盘是否正常工作,并对其进行分区和格式化。
5. 安装并配置NAS管理软件。
根据软件提供的向导,完成NAS系统的初始化设置。
四、NAS功能设置1. 创建共享文件夹:根据自己的需求,创建一个或多个共享文件夹,用于存储和共享数据。
2. 用户和权限管理:设置不同用户的访问权限,确保数据的安全性。
3. 远程访问设置:根据需要,配置并启用远程访问功能,以便在外部网络中访问NAS。
4. 数据备份与同步:设置自动备份和数据同步功能,保护数据免受意外损失。
五、其他功能扩展除了基本的文件存储和共享功能,NAS还可以通过以下方式进行功能扩展:1. 媒体服务器:可以将NAS配置为媒体服务器,通过DLNA或其他协议,在家庭网络中共享音视频文件。
2. 下载服务器:通过配置下载服务器软件,将NAS变成一个24小时运行的下载设备。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
xStack Storage TM
DSN系列产品Windows环境下
快速安装配置手册(图示) Array
D-Link xStack Storage iSCSI SAN Arrays
DSN-1100/DSN-2100/DSN3-XXX/DSN-5XXX
Installation Wizard
Version1.0
2009.1.20
第一章硬件安装
磁盘阵列在安装前,建议详细检查外观,确认是否有破损或者有异响,察看是否运输等问题造成的设备故障。
安装所需环境:
配置主机一台,服务器、笔记本等均可,有网络接口,10/100/1000Base-T均可。
磁盘阵列GUI管理软件需要JAVA运行环境支持。
在D-Link产品Firmware2.0版本以后,可以支持到J2SE v1.6–JRE;早先的Firmware1.0系列版本只能支持到J2SE v1.4.2–JRE。
相关软件,可以在以下网站下载(/products/archive/)
应用服务器一台,Windows操作系统,用于挂载ISCSI存储设备,承担客户应用系统。
应用服务器上如利用自身网卡进行数据传输,需选装微软的Microsoft iSCSI Software Initiator,建议安装2.0以上的版本。
下载地址如下
(/downloads/details.aspx?familyid=12cb3c1a-15d6-4585-b385-befd1319f825&displaylang=en)
设备连接示意图:
磁盘阵列的数据传输端口没有缺省IP地址,不会与服务器及网络的IP地址产生冲
突;但磁盘阵列的管理端口含缺省的IP地址,所以建议只连到管理PC上,避免造
成不必要的影响。
第二章系统初始化设定
首次登陆系统相关设定
1.登陆
磁盘阵列默认的初始管理IP地址为:192.168.1.1;打开IE浏览器,输入管理端ip地址后,会自动跳转到Https连接状态,确认连接后,即可打开管理界面。
IE浏览器会运行一些可执行程序,如果您的浏览器安全级别设置的偏高,可能会导致浏览器无法正常打开管理界面。
点击最下方“I Accept the End User License Agreement”按钮,进入系统管理员帐户设定。
2.系统管理员密码设定
缺省的系统管理员用户名:admin;密码:admin。
如果不填写,系统自动默认初始值。
3.管理端口IP地址设定
建议不修改默认值,如果此设备要连接到客户应用网络中以便日后管理,请联络系统管理员,确认新分配的地址。
4.数据端口IP地址设定
依据设备的不同,会分别提示输入DATA Port0-4(0-7)的ip地址设定,建议直接点击“Next”按钮直接跳过,在稍后的网络管理中按需求配置。
5.Email事件通知
该功能通常需要SMTP服务支持,一般客户很少有SMTP服务器,建议直接跳过。
6.配置结束
配置结束后,会将相关的信息显示出来。
点击“Finish”按钮,磁盘阵列系统会重启相关服务。
7.重新登陆
系统重启后,会自动跳转到系统登陆界面,点击第一行的“Click here”便进入系统管理界面。
登陆过程中会自行启动Java运行环境。
因管理软件会调用某些windows相关插件,如果您的Windows系统不曾安装过,可能会无法正常启动磁盘阵列管理软件,可点击后两行的按钮,自动安装Windows相关插件。
8.阵列管理
在左侧菜单栏,显示加入管理列表的磁盘阵列设备,右侧为系统管理员帐户和密码的输入区。
再此管理界面下,可添加多台D-Link xStack磁盘阵列(Add xStack),进行统一管理。
磁盘阵列的管理软件需要浏览器的安全较低,需JAVA小程序运行等相
关选项打开,否则会导致无法IE浏览器正常打开阵列管理软件。
第三章系统管理
系统管理主要是浏览阵列相关信息,进行磁盘阵列维护等工作,D-Link公司会定期的推出新版本磁盘阵列的管理系统Firmware,请关注D-Link公司的网站,以便升级您的设备。
在下面图例中,我们将演示如何更新磁盘阵列的系统管理软件。
不需要更新系统的客户可直接跳过此章节。
1.磁盘阵列信息
2.磁盘阵列系统信息
可以看到相关的系统日志,了解磁盘阵列的运转信息。
3.系统设定页面
“Settings”页面下,可查阅阵列系统的版本信息,以及对磁盘阵列进行关机、重启等操作。
点击“Upgrade”可弹出文件浏览窗口,浏览管理pc本地文件夹,进行Firmware的上传。
4.选择系统软件
磁盘阵列的系统Firmware文件以FRU开头,中间数字部分是版本信息,后面的型号用于对应阵列型号。
磁盘阵列的型号不同,更新软件也不同,通常DLink后面没有型号注明是适用于
2XXX和3XXX系列产品,DSN1100和DSN5XXX系列产品因设备硬件系统的差异有
自己的升级文件。
截至到2009年1月,最新的系统版本是2.5.1.63。
确定磁盘阵列匹配的升级文件后,系统会提示文件上传,并于上传完成后自动重新启动。
6.系统更新
系统软件通常在30兆左右,上传文件需要一点时间,请耐心等待,并确保磁盘阵列在上传文件过程中网络和供电系统不要中断。
系统更新完成后,会提示“系统软件更新成功”,点击“确定”阵列重启。
8.管理软件重新连接
在从2.0升级到2.5的系统版本后,因系统版本差异,原来的打开的管理软件无法正常管理新的磁盘阵列系统,需要关闭原有的管理软件,重新登陆管理。
9.重新登陆
新的登陆界面比2.0版本多了一行,用于导出系统日志进行故障分析。
10.系统核查
升级完毕后,请进入管理界面的系统设备页面,核对相关的版本信息。
系统会列出设备原有的Firmware信息,并允许转换回原有的系统软件。
11.新增加的功能
2.5版本的Firmware增加了对阵列控制器相信信息的查询及管理。
第四章配置网络
1.网络管理界面
在右侧信息窗口中,会显示出所有端口,如该端口已插上网线,状态会显示为已连接。
右键点击要配置的网口,选择“Create Portal”即可配置IP地址。
2.端口绑定(LAG方式)配置
右键点击网口设备,选择“Group Ports”。
在网口选择中,按“Ctrl”可执行多选。
如果需开启VLAN功能,则需要在该功能前打√。
配置后显示如下:
第五章配置卷
1.进入卷管理页面
在左侧菜单选取“Physical Storage”,在右侧信息栏中可查看所有硬盘信息,硬盘如果有损坏,会用红色标记出来,并注明Failed。
在左下侧的操作命令中,点击“Volume Creation Wizard”即可弹出卷设定页面。
2.卷命名
在下面的两个选项中,选取下面的一个,手动选择相关参数,比较适合工程师操作,更容易按客户需求配置出所希望的卷。
3.选择卷的Raid级别设置
按照顺序分别是:Raid10,Raid5,Raid1,Raid0,JBOD模式
4.选择磁盘数量
选择所需要的磁盘数量,不能超出最低的理论值。
注:因演示环境磁盘损坏,无法正常进行下去,接下来的配置比较简单,输入卷的大小,确认什么主机可以访问到磁盘,即可完成全部配置。
后续更新的文档中会列出相应的图片。
第六章服务器加载卷
1.服务器运行Initiator
正确安装Initiator后
点击桌面上的按钮
2.添加ISCSI设备
在Discovary页面下,点击“Add”,输入iscsi阵列数据传输端口IP地址,如果在磁盘阵列端没有修改端口号,默认都是3260。
3.加载卷
在Targets页面下,会列出磁盘阵列端所设定好的卷,标记后“Log On”即可。
然后在Windows系统的“计算机管理—存储—磁盘管理”中,可扫描到新的磁盘,格式化后即可使用。