QB2000F单点壁挂式气体检测报警器

合集下载

QB2000甲烷报警器

QB2000甲烷报警器

QB2000甲烷检测报警器QB2000甲烷检测报警器产品描述:QB2000甲烷检测报警器由报警监控器和气体探测器等构成,可混合配接多种气体探测器,安装布网方便,实现1~8路物理量和48路数字量的测量、显示和公共报警控制。

QB2000甲烷检测报警器是我公司研制的多点监控气体检测报警控制器,用于检测环境空气中甲烷气体的浓度。

QB2000甲烷检测报警器广泛用于需要防火、防爆、防中毒的场所进行气体安全检测报警。

QB2000甲烷检测报警器采用嵌入式32位微处理器作为控制单元,高精度进口传感器作为检测变送器,灵敏度高,响应速度快。

QB2000甲烷检测报警器功能特点:先进的32位超低功耗嵌入式微控制器128*64点阵液晶显示全中文菜单方便国内用户使用多种气体混合安装探测器故障自动检测报警记录自动存储500条密码管理功能,重要操作需密码验证,有效防止误操作可接1-8个4-20mA和48路RS485信号输出的探测器最多4个报警继电器联动输出,继电器配置可编程QB2000甲烷检测报警器技术参数:容量:1~48只探测器8只4-20mA信号探测器48只RS485信号探测器检测气体:可燃气检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示报警设定:一级浓度报警点程序设定二级浓度报警点程序设定报警提示:超高亮发光报警提示报警方式:声光报警>110分贝报警输出:无源节点,容量AC 220V 3A环境温度:-10°~50°环境湿度:>90%无结露防爆等级:Exd II CT6防护等级:IP44电源:AC220V,50HZ<4W传输距离:<1000m RVVP3*1.5m㎡屏蔽线尺寸重量:25cm*38cm*10cm 3.0kg注释:根据用户需要选配不同功能及配件QB2000检测报警器检测气体参数:产品名称被测气体测量范围分辨率响应时间一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒光气检测仪/报警器0-1PPM 0.01PPM ≤30秒苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒苯检测仪/报警器0-100PPM 1PPM ≤30秒甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。

QB2000氧气检测控制器

QB2000氧气检测控制器

QB2000氧气检测控制器QB2000氧气检测控制器产品描述:QB2000氧气检测控制器既可以更换同种类型传感器,也可以更换不同气体种类传感器、不同量程传感器模块,操作和识别自动完成。

QB2000氧气检测控制器无论何种传感器模块插入后,无需标定设置。

探测器自动识别,读取出厂标定数据和相关设置值,自检完成后即刻运行。

QB2000氧气检测控制器新出厂传感器模块更换到老探测器上,即可让探测器具备出厂一样的检测、报警准确性,达到计量等检测要求。

QB2000氧气检测控制器一旦最容易损坏及过期的传感器失效后,通过一体化探测器的方便更换性,客户即可查找解决问题,避免了上门服务的延误和人工费用。

QB2000氧气检测控制器在当环境中氧气浓度达到或超过预置警报值时,报警器立即发出声光报警,以提醒及早采取安全措施,并驱动排风、控制系统,防止发生爆炸、火灾、中毒事故,从而保障安全生产。

QB2000氧气检测控制器功能特点:先进的32位超低功耗嵌入式微控制器128*64点阵液晶显示全中文菜单方便国内用户使用多种气体混合安装探测器故障自动检测报警记录自动存储500条密码管理功能,重要操作需密码验证,有效防止误操作可接1-8个4-20mA和48路RS485信号输出的探测器最多4个报警继电器联动输出,继电器配置可编程QB2000氧气检测控制器技术参数:容量:1~48只探测器8只4-20mA信号探测器48只RS485信号探测器检测气体:氧气检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示检测误差:≤±5%F.S响应时间:T90<30s显示方式:LED数码管显示或LED液晶显示报警设定:一级浓度报警点程序设定二级浓度报警点程序设定报警提示:超高亮发光报警提示报警方式:声光报警>110分贝报警输出:无源节点,容量AC 220V 3A环境温度:-10°~50°环境湿度:>90%无结露防爆等级:Exd II CT6防护等级:IP44电源:AC220V,50HZ<4W传输距离:<1000m RVVP3*1.5m㎡屏蔽线尺寸重量:25cm*38cm*10cm 3.0kg注释:根据用户需要选配不同功能及配件QB2000检测控制器检测气体参数:产品名称被测气体测量范围分辨率响应时间一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒光气检测仪/报警器0-1PPM 0.01PPM ≤30秒苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒苯检测仪/报警器0-100PPM 1PPM ≤30秒甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。

QB2000F单点壁挂式一氧化碳检测报警器

QB2000F单点壁挂式一氧化碳检测报警器

QB2000F单点壁挂式一氧化碳检测报警器QB2000F单点壁挂式一氧化碳检测报警器产品描述:QB2000F单点壁挂式一氧化碳检测报警器,是一种固定式可连续检测作业环境中一氧化碳浓度的仪器。

QB2000F单点壁挂式一氧化碳检测报警器为自然扩散方式检测气体浓度,采用进口电化学传感器,具有极好的灵敏度和出色的重复性。

QB2000F单点壁挂式一氧化碳检测报警器大屏幕液晶屏实时显示泄漏气体的浓度值,超过预设报警点立即启动声光报警号或驱动排风系统。

QB2000F单点壁挂式一氧化碳检测报警器仪器采用嵌入式微控制技术,全中文菜单操作简单,便于中国人使用,功能齐全,非常可靠。

QB2000F单点壁挂式一氧化碳检测报警器功能特点:仪器采用先进的32位嵌入式微控制器128*64点阵图形液晶显示用户可自行设置高低报警点全中文菜单方便国内用户使用首次报警时间显示功能具有实时时钟功能自动校准功能,减少测量误差报警记录自动存储200条备用电池非报警状态下可工作2小时以上(用户选配)标准4-20mA信号可直接接入工厂DCS系统(用户选配)RS485数字信号可与工厂上位机连接(用户选配)传感器模块更换后可自动识别,无需重新标定,传感器模块可与我公司模块化探测器通用QB2000F单点壁挂式一氧化碳检测报警器技术参数:测量范围:0-100%LEL显示误差:≤±3%F.S响应时间:T90<30s显示方式:128*64点阵式液晶屏实时显示数据及系统状态报警提示:广角高度发光提示、100dB蜂鸣音随浓度增加频率加大报警点:一级报警用户设定二级报警用户设定报警输出:两路继电器输出,容量AC 220V 2A信号输出:国际标准4-20mA信号可直接接入工厂DCS系统(用户选配)RS485数字信号与工厂上位机连接(用户选配)工作环境:-30°~+50°;湿度<95%RH无结露工作电压:AC 220V 50HZ备用电池供电可连续工作2小时以上(用户选配)防护等级:IP65重量:约1200gQB2000F检测报警器检测气体参数:产品名称被测气体测量范围分辨率响应时间一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒光气检测仪/报警器0-1PPM 0.01PPM ≤30秒苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒苯检测仪/报警器0-100PPM 1PPM ≤30秒甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。

单点壁挂式气体检测报警仪HD1100

单点壁挂式气体检测报警仪HD1100

南京汇登电子科技有限公司地址:南京市白下区洪武路336号HD1100单点壁挂式气体检测报警器使用说明书南京汇登电子科技有限公司Nanjing Huideng Electronic Technology Co.,Ltd专业是基础服务是保证质量是信誉目录1、使用注意事项 (1)2、概述 (2)3、工作原理 (2)4、技术性能及参数 (3)5、安装说明 (4)6、仪器参数设置说明 (5)7、标定说明 (6)8、常见故障及维修 (7)9、产品成套性 (7)附录、标定记录 (8)附录:标定记录型号:HD1100单点壁挂式气体检测报警器规格:仪器编号:传感器编号:出厂日期:温馨提示在使用仪器前请仔细阅读本说明书1.使用注意事项A.在使用仪器之前,仔细阅读操作手册。

B.本仪器的使用必须按我公司指定的工作规程。

C.我公司负责该产品12个月的保修(保修期从用户拿到仪器之日算起)。

用户在使用中应遵守使用说明,任何由用户操作不妥造成的仪器损坏,不在保修范围之内。

D.在维修仪器和更换部件时必须采用我公司的原装部件,并在本公司授权下由受过专门培训的人员来完成。

如果用户自行修理更换部件,仪器的可靠性责任由操作者负责。

E.传感器内有酸溶液,用户不要拆卸,还要注意不要损坏传感器正面的薄膜。

如果操作不当,传感器内酸液泄漏到皮肤上,应及时用水连续冲洗接触部位10分钟。

F.仪器需每年标定一次;仪器的传感器的隔爆片部位要定期清理(用低压压缩空气吹扫),否则灰尘杂质堵塞防护孔会影响检测的灵敏度。

G.本仪器的使用还应遵守国内有关部门及工厂内仪器管理方面的法令和规则。

2、概述随着工业的迅速发展,人类接触有害气体及易燃易爆气体的场所越来越多,由此造成对人类本身的危害越来越大。

一次次的中毒或爆炸事故,使人们清醒的认识到在发展工业的同时保护人类自身安全的重要性。

因此各种有害气体及易燃易爆气体报警仪器渐渐成为工业安全中必不可少的防护设备。

HD1100单点壁挂式气体检测报警器主要用于工业现场非防爆场合的气体检测报警,该仪器采用进口电化学传感器,准确度高、线性好;具有(4~20)mA电流信号输出、RS485输出功能,便于与其它仪表或控制器连接;配备两路开关量控制信号输出,可控制排风扇、电磁阀等设备。

QB2100柜式控制器 说明书(2)

QB2100柜式控制器 说明书(2)

体报警控制器QB2100型气使用说明书V1.2目录11、产品概述 (3)2、技术指标 (3)3、产品介绍 (4)3、1产品使用 (5)3、2功能设置与操作级别 (7)3、2、1一级菜单操作 (7)3、2、2二级菜单操作 (10)3、2、3三级菜单操作 (11)4、控制器与探测器的链接 (12)4、1控制器尺寸(单位:mm) (12)4、2控制器与探测器的链接 (12)5、配套使用的探测器 (14)5、1技术参数: (14)5、2安装位置: (15)6、产品的维护 (16)6、1注意事项 (16)6、2常见故障的分析与排除 (16)6、3 保修期 (17)21、产品概述QB2100可燃/有毒气体报警控制器,是我公司开发的功能实用,操作方便的可燃/有毒气体报警控制器,可与我公司的可燃/有毒气体探测器共同组成工业用气体报警系统。

控制器亦可通过RS485信号上联至监控中心计算机或图形显示装置。

从而构成远程监控、本地监控、现场监控的多级监控网络,大大提高了监控的实时性、准确性。

该产品采用壁挂式安装,每一个地址对应一个探测器。

通过与探测器的配合使用,并通过控制器单片机对探测器上传的数据进行的各种数据处理,最终完成数据的显示、报警、输出和控制等功能。

本产品的设计、制造及检验均遵循以下国家标准:GB16808-2008 《可燃气体报警控制器》GB12358-2006 《作业场所环境气体检测报警仪通用技术要求》GB15322.1-2003 《测量范围为0~100%LEL的点型可燃气体探测器》2、技术指标安装方式:柜式安装工作电压:主电:220VAC/(50~60)Hz3备电:24VDC/4.6AH(可选)额定功率:≤10W工作温度: 0℃~ + 40℃工作湿度:(10~95)%RH探测器输入:三线制或四线制电源线≥1.5mm2(国标线)信号线≥1.5mm2(双色双绞线)报警方式:声音报警:分故障报警、浓度报警两种不同的声音。

CHK-2000型气体报警控制器说明书

CHK-2000型气体报警控制器说明书

CHK-2000型气体报警控制器说明书产品目录1概述12特点13主要参数14安装14.1安装方式14.2外形尺寸15结构和功能25.1结构25.2功能25.2.1报警显示板25.2.2专线控制板25.2.3打印机25.2.4电源26系统设计与说明36.1系统组成和布线框图36.2系统布线和设计要求3 7现场调试步骤37.1绝缘电阻测量37.2编址单元编址37.3控制器静态测量3 7.4控制器空载通电检测3 7.5编制单元登记37.6联动功能测试38操作使用说明48.1正常监视状态48.2液晶屏亮度调节4 8.3故障48.4火警48.5联动48.6菜单操作48.6.1联动48.6.2设置58.6.2.1日期与时钟58.6.2.2自动登记68.6.2.3手动登记68.6.2.4部件隔离68.6.2.5联动编程68.6.2.6开关打印机6 8.6.2.7控制检测68.6.2.8联动控制方式7 8.6.2.9清除操作78.6.2.10汉字注释输入7 8.6.3查询78.6.3.1登记地址查询7 8.6.3.2隔离地址查询7 8.6.3.3联动编程查询7 8.6.3.4控制检测查询8 8.6.3.5当前故障查询8 8.6.3.6汉字注释查询8 8.6.3.7历史记录88.6.4测试88.6.4.1部件状态信号9 8.6.4.2模拟量曲线98.6.4.3回路信号浏览98.6.4.4地址类型状态98.6.4.5控制器自检99联动逻辑编程语句格式910使用与维护1011运输、储存1012随机附件1013其它101概述CHK-2000型可燃气体报警控制器(以下简称控制器)是我公司为了满足燃气市场的不断发展需求而研制开发的新产品。

它是二总线可燃气体报警控制器,集气体泄漏报警和联动控制于一体,可以与我公司生产的防爆型燃气探测器及各种模块等设备组成智能化的总线型可燃气体报警控制系统。

该系统比较适用于中、小型建筑面积的火情监测和控制。

汉威科技 GTQ-WD 系列 工业及商业用途 点型可燃气体探测器 使用说明书

汉威科技 GTQ-WD 系列 工业及商业用途 点型可燃气体探测器 使用说明书

GTQ-WD系列工业及商业用途点型可燃气体探测器使用说明书(使用产品前请仔细阅读本说明书)产品型号:GTQ-WD2200/WD6200汉威科技集团股份有限公司Hanwei Electronics Group CorporationISO9001/ISO14001/OHSAS18001国际管理体系认证企业Ver:00196感谢您购买汉威科技产品。

当您准备使用本产品时请务必仔细阅读使用说明书,并按照所提供的有关操作步骤进行,以使您能充分享受我公司提供的服务,同时避免因误操作而损坏本机或发生其它意外。

如因人为原因导致设备损坏,将会导致保修条款失效。

汉威科技全权负责本说明书的编制及修订,并尽量确保说明书内容正确无误,同时本公司将保留改进产品和修改说明书而不预先通知的权利。

本说明书中的图片仅用于功能说明,若与实物不符,请以实物为准。

请妥善保管本说明书,以便在您日后需要时能及时查阅、获得帮助。

符号定义在开始使用前,请先熟悉可能出现在本说明书中的符号:注意—可能伤及自己或他人。

小心—可能损坏探测器或其它设备。

备注—注释、使用提示或附加信息。

版权声明本使用说明书版权属汉威科技集团股份有限公司所有,未经书面许可,说明书中的任何部分不得复制、翻译、存储于数据库或检索系统内,也不可以电子、翻拍、录音等任何手段及方式进行传播。

用户服务指引1购买产品后,请根据装箱单仔细核对附件、合格证及产品保修卡等是否齐全,若发现不全,应立即与销售商或厂家联络。

2本产品自售出之日起十二个月内,凡用户遵守贮存、运输及使用要求,而产品质量低于技术指标的,凭产品保修卡享受免费维修。

3如果您对我们提供的产品和服务有任何疑问或不满,包括产品技术、质量、安装维修、服务态度、收费标准等问题,请您及时联络我们,我们将会对您的意见及时进行妥善处理。

安全事项在使用本产品之前,请务必阅读以下安全事项并严格遵守相关操作要求。

1使用前请检查探测器外壳有无裂痕或是否缺少零部件。

ATO SKY2000 气体检测仪用户手册说明书

ATO SKY2000 气体检测仪用户手册说明书

Pumping Type Gas DetectorSKY2000User ManualWelcome to visit !Email:*************Tel: +1 800-585-1519 (Toll-free)Global Shipping Enabled*** Thanks for purchasing our product. Please read the user manual carefully before using. *** Keys Operation:Turn on/off: long press for 3s to turn on/off the device, short press to confirm or save data.Menu: in detection mode, press this button to enter into parameter setting mode, and in parameter setting mode, press this button to move the cursor.Plus: in parameter setting mode, short press it to select items upward or add value. Long press for 3 seconds to turn on/off alarm function quickly.Minus: in parameter setting mode, short press it to select items downward or decrease value. Long press for 3 seconds to turn on/off air pump quickly.Exit: in parameter setting mode, short press it to go back to previous menu. Long press to shift the gas concentration unit quickly.Power On / OffPut the detector in clean air, and press the “ON/OFF” for three seconds, the detector will be turned on and the pump will start to work. The screen displays the following interface successively: Brand and Logo, main parameter interface, initialing countdown. The countdown would be 60 or 120 seconds, which is to make sure that the sensors are fully activated. After countdown, the device enter normal detection interface.Take the detector out of the detected environment and wait for the data to get down to zero, then press the “ON/OFF” to turn off the detectorZero CalibrationZero calibration must be done in clean air. Better to do once after alarming happens.Press “MENU” to enter parameter setting mode, select the "calibrate zero", and press “ON/OFF” to enter the mode. Observe the value of “real time concentration”. If the reading is not zero and the drifting is too big when the reading is stable, then it is necessary to conduct zero point calibration.Press “ON/OFF”, the real-time concentration will go back to zero, and press ”ESC” to go back to detection mode, gas concentration values also back to zero.Note: Zero calibration of oxygen detector, nitrogen detector and carbon dioxide detector (target gases are component of the air) cannot be done in the air. Only the target point calibration (value of target point concentration is the standard concentration values in the clean air) can be done.Process of Over-range incorrect operationUsers should avoid using gases which exceed the measure range to impact the sensor, because it will affect the lifespan and sensitivity of the sensor, even, "poison" the sensor. If there is any over-range incorrect operation makes the detector displaying an concentration at a large reading, the remedy is to take the device out of the environment immediately and put it in clean air for over half an hour, and then observe the reading, if it keeps going down, then wait until the reading back to zero before powering it off, and do the zero point calibration next time before using it. If the reading maintained at full scale, user should send the device back to manufacturer or agent for repair or replacing the sensor.①— Air Inlet②— Air Outlet③— air chamber of sensor④— LCD⑤— PLUS⑥— MINUS⑦— MENU⑧— ESC⑨— ON/OFF----------------------------------------------------------------------------------------------------------------------------- Note*If detector is used for the gas cylinder detection, considering the high pressure in the cylinder, please use a pressure regulator, and keep it as the below data:Flow rate: 800mL~1L/minutePressure: 0.1MPa or 1Bar*Please put the detector in clean air for about 5 minutes and waiting for the data falling down to normal before turning it off after measurement.Operation InterfaceWhen the detector is turned on completely, the device will enter the detecting interface. The gas type will be showed on the top left, and the time and battery power will be at the right. In the middle, there is the real- time concentration. There will be BEEP-ON at the bottom left, which means the alarm is on. The PUMP-ON at the bottom right, which means the pump is working.Alarm StatusWhen the detected gas concentration is higher than the low alarm value, the alarm sound will be on, yellow light will be flickered.When the detected gas concentration is high than the high alarm value, the alarm sound will be on, red light will be flickered.Alarm SettingPress “Menu”, choose the “Alarm point set”, and start to set the alarm value.There are LOW POINT and HIGH POINT for set, press “MENU” to move the cursor to the value you want to set, and press the “PLUS” or “MINUS” to change the value. After the setting is done, press “ON/OFF” button to save the settings.Low Battery AlarmWhen the battery is low, there will be sound, light low battery alarm. There will be sound and light every 5 seconds to remind the user to charge the device in time. When the battery is used up, the device will be turned off automatically.Restore SettingWhen all the settings are wrong, or users operate the detector in a wrong way, you can restore the detector to factory settings. But if the detector works normally, please don’t operate this setting. In order to avoid wrong setting, password is needed. If you want to restore the detector to factory setting, please contact the supplier.Storage S et tingIn the storage setting, you can set the storage status and the interval. Every time you turn on the detector, the storage status defaults OFF, so you need to set the storage status if you want to record the data.Press MENU, choose the “Storage set”, move the cursor by pressing MENU at the “ENABLE”, press MINUS to change NO to YES.The storage interval can be 5 seconds, 10 seconds, 15 seconds, etc. The highest interval is 1 hour.(* The storage setting only for gas detector with data storage function)View H istory D ataPress the MENU, choose “view history data”. Then at the top is the record total number, and the reminder “PLEASE SELECT”. Now, if you press MINUS, then the record data will be from the first record to the second in turn. If the record number is above 10, and you want to check the specific number, you press the MENU again, then you can input the exact number and check that record(press the MENU to move the cursor, and press the MINUS and PLUS to change the number), press ON/OFF to confirm and then you will see the detailed record.In the detailed record interface, at the top are the record total number and current number. In the middle are the date and time, and the concentration is at the bottom.Erase H istory D ataTo make sure the detector work perfectly and you can check the history data quickly, we suggest you to erase the history data regularly. Press MENU, choose the “Erase ex_flash”, password is needed (the password is 9999), then press ON/OFF, it shows that “erasing”, and when finished, it will turn back to the detecting interface. Target Point CalibrationNote: Calibration needs to be done by professionals and with necessary accessories and standard gas.Prepare the standard gas before starting the target point calibration. In detection mode, press “MENU”, select “calibrate span”, press ON/OFF button to enter. Then you will need to enter password. (If you need password, please contact the manufacturer to get it)After entering the password successfully, press ON/OFF to enter the target point calibration interface, as shown in the picture. The interface will display “concentration”, “set value. The concentration is the result got from the calculation of several internal calibration parameters. The process of calibration is the process to recalculate the internal parameters of the device. The set value is the value need to be entered manually; it should be the concentration of the standard gas to be calibrated. Select the parameter under the current interface, modify its value with “PLUS” and “MINUS” button.The calibration process is as below:1.Connect the detector with standard gas cylinder by hose.2.Enter the target point calibration interface, set the “SET value”as the standard gas concentration.3.Release the standard gas to the detector in a flow rate of500mL/min. The value of “concentration” will become largergradually, and become stable after 30seconds.4.When the value of “concentration” is stable, press the “ON/OFF” button, the value of “concentration” will be same with oralmost same with the “Set value”. The calibration is finished.5.Cut off the standard gas supply. Press “ESC” to go back todetection interface.。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

QB2000F单点壁挂式可燃气体检测报警器
QB2000F单点壁挂式可燃气体检测报警器产品介绍:
QB2000F单点壁挂式可燃气体检测报警器,单点壁挂式氧气检测报警器,可燃性气体浓度氧气浓度连续检测仪,有毒有害气体浓度监测。

QB2000F单点壁挂式可燃气体检测报警器可更换不同芯片,检测不同气体,现场声光报警,控制接点输出,仪器采用嵌入式微控制技术,全中文菜单操作简单,功能齐全,可靠性高,整机性能居国内领先水平。

QB2000F单点壁挂式可燃气体检测报警器功能特点:
仪器采用先进的32位嵌入式微控制器
128*64点阵图形液晶显示
用户可自行设置高低报警点
全中文菜单方便国内用户使用
首次报警时间显示功能
具有实时时钟功能
自动校准功能,减少测量误差
报警记录自动存储200条
备用电池非报警状态下可工作2小时以上(用户选配)
标准4-20mA信号可直接接入工厂DCS系统(用户选配)
RS485数字信号可与工厂上位机连接(用户选配)
传感器模块更换后可自动识别,无需重新标定,传感器模块可与我公司模块化探测器通用QB2000F单点壁挂式可燃气体检测报警器技术参数:
测量范围:0-100%LEL
显示误差:≤±3%F.S
响应时间:T90<30s
显示方式:128*64点阵式液晶屏实时显示数据及系统状态
报警提示:广角高度发光提示、100dB蜂鸣音随浓度增加频率加大
报警点:一级报警用户设定二级报警用户设定
报警输出:两路继电器输出,容量AC 220V 2A
信号输出:国际标准4-20mA信号可直接接入工厂DCS系统(用户选配)
RS485数字信号与工厂上位机连接(用户选配)
工作环境:-30°~+50°;湿度<95%RH无结露
工作电压:AC 220V 50HZ
备用电池供电可连续工作2小时以上(用户选配)
防护等级:IP65
重量:约1200g
QB2000F检测报警器检测气体参数:
产品名称被测气体测量范围分辨率响应时间
一氧化碳检测仪/报警器CO 0-1000PPm 1PPm ≤30秒
氧气检测仪/报警器O2 0-30%VOL 0.1%vol ≤30秒
臭氧检测仪/报警器O3 0-5PPm 0.01PPm ≤30秒
硫化氢检测仪/报警器H2S 0-100PPm 1PPm ≤30秒
氢气检测仪/报警器H2 0-1000PPm 1PPm ≤30秒
氯气检测仪/报警器CL2 0-20PPm 0.1PPm ≤30秒
氨气检测仪/报警器NH3 0-100PPm 1PPm ≤30秒
二氧化硫检测仪/报警器SO2 0-20PPm 0.1PPm ≤30秒
一氧化氮检测仪/报警器NO 0-250PPm 0.1PPm ≤30秒
二氧化氮检测仪/报警器NO2 0-20PPm 0.1PPm ≤30秒
环氧乙烷检测仪/报警器ETO 0-100PPM 1PPM ≤30
二氧化氯检测仪/报警器CLO2 0-20PPM 0.1ppm ≤30秒
甲醛检测仪/报警器CH2O 0-50PPm 0 0.01PPm ≤30秒
氯化氢检测仪/报警器HCL 0-20PPm 0.5PPm ≤30秒
可燃气体检测仪/报警器EX 0-100%LEL 1% ≤30秒
氰化氢检测仪/报警器HCN 0-20PPM 0.1PPM ≤30秒
丙烯腈检测仪/报警器CH2=CHCN 0-100PPM 1PPM ≤30秒
氟化氢检测仪/报警器HF 0-20PPM 0.1PPM ≤30秒
光气检测仪/报警器0-1PPM 0.01PPM ≤30秒
苯乙烯检测仪/报警器0-100PPM 0-200PPM 1PPM ≤30秒甲苯检测仪/报警器0-100PPM 1PPM ≤30秒
苯检测仪/报警器0-100PPM 1PPM ≤30秒
甲醛检测仪/报警器0-100PPM 1PPM ≤30秒。

相关文档
最新文档