正泰电能表DDS666单相电能表使用说明书

合集下载

正泰 DDSU666.004.0006型单相电子电能表(DIN-Rail)使用说明书

正泰 DDSU666.004.0006型单相电子电能表(DIN-Rail)使用说明书

Type DDSU666.004.0006Single phase electronic energy meter(DIN-Rail)Operation ManualZTY0.464.1224Zhejiang Chint Instrument & Meter Co., Ltd.May, 20191. Brief Introduction1.1 Main application & applicable rangeType DDSU666 single phase electronic energy meter (din-rail) (hereinafter referred to as the “instrument”) is designed based on power monitoring and energy metering demands for electric power system, communication industry, construction industry, etc. as a new generation of intelligent instrument combining measurement and communication function, mainly applied into the measurement and display for the electric parameters in the electric circuit including voltage, current, power, frequency, power factor, active energy, etc. The network can be realized through RS485 communication interface and external device. Adopting the standard DIN35mm din rail mounting and modular design, it is characterized with small volume, easy installation and easy networking, widely applied into the internal energy monitoring and assessment for industrial and mining enterprises, hotels, schools, large public buildings.Complied standards:IEC62052-11《Electricity metering equipment(AC)-General requirements, tests and test conditions- Part11:Metering equipment 》;IEC62053-21《Electricity metering equipment(AC)-Particularrequirements-Part21: Static meters for active energy(classes 1 and 2)》;MODUS-RTU protocol.1.2 Product Features1)Metering the positive and negative active power;2)Adopting wide LCD, it has clear vision.3)RS485 communication function with communication protocol complied with Modbus-RTU;4)Adopting DIN35mm standard din rail mounting, structural modular design, it is characterizedwith small volume, easy installation and easy networking.1.3 Model composition and meaningsFigure 1 Model No. & meanings1.4 Applicable environmental condition.Regulated working temperature range: -25℃~+60℃;Limited working temperature range: -35℃~+70℃;Relative humidity(Annually average):75%;Atmospheric pressure:86kPa~106kPa。

1.读卡器或售电机操作说明书(RW666型)

1.读卡器或售电机操作说明书(RW666型)

1.读卡器或售电机操作说明书(RW666型)正泰售电机管理系统软件(RW666型IC读卡器)一、安装好售电系统后(不要安装在C盘),装好读卡器的电源线、数据线连接上后,系统提示发现新硬件,安装好驱动后。

将电表包装盒内的“购电卡”插入读卡器(箭头指示的方向朝上,推进出用力压到位,直到不能弹出后松手)。

拔卡方法:再压-松手弹出。

二、适用于:正泰生产DDSY666、DTSY666电能表产品。

三、进入软件:系统默认管理员123,密码123,进入.四、修改电价:用户管理→电价维护→删除不需要的电价类型→双击需要修改的电价单价值→改成小区售电电价→保存五、修改密码(此步骤由用户决定是否修改)用户管理→修改密码→原密码123→输入两遍新密码→确定六、建档用户管理→档案管理→增加→用户编号、电表编号任意编制数字(用户号可以与电表号相同但不能与档案中已存在的其他用户相同,即一户一号),输入用户名称(如张三,可不写)、输入用户地址(如1号楼1单元101),证件代码、用户电话可输可不输,电表类型选择单相电能表(如果是三相表就选择三相表,当选择三相表后弹出CT值,一般为1,加互感器的除外,后面有说明。

)→点击保存→出现提示是否制作初始化卡→点击“是”→将新卡插入读卡器→点初始化卡操作中的“写卡”输入一级报警:10,二级报警:5,负荷阀值:40 (电表的最大工作电流,家用电器实际工作电流≥设置数值,电表自动跳闸断电,例如:5/20A电表,最大工作电流20A,10/40A电表,最大工作电流40A,如果用户负载或电器功率大,最大工作电流+10A)→选择电价类型→选中“度数或金额”→输入第一次售电度数或者金额→点击“确认写卡”→出现初始化卡制作成功→拨出读卡器中的卡→在卡的背面标注用户名“张三”→发卡给张三。

这里需要注意一点:做好的初始化卡第一次插入哪块电表后,以后该表只认这张卡,而这张卡也只能给这块表充电,所以第一次卡一定插对。

正泰DDSY666

正泰DDSY666

1.概述DDSY666型单相电子式预付费电能表是用来计量工频交流单相有功电能,并可实现电量预购、限流保护等功能的电子式电能表。

本产品适用于工业和民用单相交流电路。

符合GB/T 17215.321-2008《交流电测量设备 特殊要求 第21部分:静止式有功电能表(1级和2级)》标准和GB/T 18460.3-2001《IC卡预付费售电系统 第3部分:预付费电能表》标准中队单相预付费电能表的全部技术要求。

本产品采用了优选大规模专用集成电路,应用微计算机、表面安装(SMT)、电磁兼容等技术,电路集成度高,结构合理,性能可靠;专用电卡(IC卡)可实现先付费后用电、表内剩余电量不足时自动报警;剩余电量为零时,自动断电;能实现可编程最大功率限制,当用户负荷超过最大功率限制值时自动断电报警等功能,可双向计量电能,独特的保密措施保证用户使用电表和电卡的高度安全性。

2.结构特征与工作原理2.1结构特征本产品采用阻燃ABS树脂外壳,具有较高的绝缘强度和耐腐蚀性,IC卡插口设在罩壳上方右侧位置,具有防窃电、防潜动等功能,造型新颖,美观适用。

2.2工作原理电流回路的电流通过分流器采样得到的电压信号,再通过电能专用计量芯片内部,得到数字相位校正和高通滤波的数字信号进入数字乘法器的一个输入端。

电压回路的电压信号经过电阻分压器取样,再通过电能专用计量芯片内部得到数字信号,进入数字乘法器的另一个输入端与电流通道的信号进行乘法运算,完成被计量电能的瞬时功率测量。

乘法器输出瞬时功率通过数字低通滤波器进行积分处理进入“数字/频率”转换器,变换成与被计量电能平均功率成比例的频率脉冲信号(分为高频脉冲信号和低频脉冲信号),其中高频脉冲输出至测试脉冲输出和用来驱动脉冲指示灯,低频脉冲输出至微处理器接口实现电能计量。

LED清晰地显示出电能值及其它有关内容;功率反向时,电能表仍然能准确计量电能值;售电部门通过售电管理系统对电卡进行初始化,并将电卡发行给用户,同时在管理系统内建立档案,用户必须向售电部门购买电量后才能用电,用户的最大功率限制值由售电部门设定。

浙江正泰仪器仪表有限责任公司PD666-□S系列数显多功能表(ZTY0.464.1220)使用说明书

浙江正泰仪器仪表有限责任公司PD666-□S系列数显多功能表(ZTY0.464.1220)使用说明书

PD666-□S系列数显多功能表使用说明书ZTY0.464.1220浙江正泰仪器仪表有限责任公司二0一九年四月1.概述1.1.主要用途及适用范围PD666-□S系列数显多功能表(以下简称仪表)主要对电气线路中的电压、电流、有功功率、无功功率、频率、功率因数、正反向有功电能、四象限无功电能、谐波含量等参数进行实时测量与显示。

广泛应用于低压配电进线开关柜、馈线开关柜等,是针对电力系统、通信行业、建筑行业等电力监控而设计,集测量、通讯、变送、报警于一体。

执行标准:GB/T 22264.1-2008《安装式数字显示电测量仪表第1部分:定义和通用要求》GB/T 22264.2-2008《安装式数字显示电测量仪表第2部分:电流表和电压表的特殊要求》GB/T 22264.3-2008《安装式数字显示电测量仪表第3部分:功率表和无功功率表的特殊要求》GB/T 22264.4-2008《安装式数字显示电测量仪表第4部分:频率表的特殊要求》GB/T 22264.5-2008《安装式数字显示电测量仪表第5部分:相位表和功率因数表的特殊要求》GB/T 22264.7-2008《安装式数字显示电测量仪表第7部分:多功能仪表的特殊要求》GB/T 22264.8-2009《安装式数字显示电测量仪表第8部分:推荐的试验方法》GB/T 17215.211-2006《交流电测量设备通用要求、试验和试验条件第11部分:测量设备》GB/T 17215.322-2008《交流电测量设备特殊要求第22部分:静止式有功电能表(0.2S 级和0.5S级)》GB/T 17215.323-2008《交流电测量设备特殊要求第23部分:静止式无功电能表(2级和3级)》1.2.产品特点1) 具有电参量测量功能(电压、电流、功率、频率、功率因数、总谐波含量);2) 具有正反向有功电能计量、四象限无功电能计量和存储功能,支持多费率计量功能。

3) RS485接口,支持ModBus_RTU、DL/T 645-2007协议;4) 模拟量输出(变送);5) 开关量输出(报警),继电器输出;6) 开关量输入;7) 具有硬件RTC功能;1.3.型号的组成及其代表意义P2134567①产品类别:正泰安装式数字显示电测量仪表②组别代号:D:多功能表③注册号:666④仪表面板尺寸代号:2:72mm×72mm 3:96mm×96mm 6:80mm×80mm 8:120mm×120mm⑤辅助功能选择:无:默认通讯功能P :默认带开关量输入和通讯功能K:开关量输出(报警)B:模拟量输出(变送)H:定制产品1.4.使用环境条件规定的工作温度范围:-10℃~+45℃;极限的工作温度范围:-25℃~+70℃。

DDSU666单相电子能量表用户手册说明书

DDSU666单相电子能量表用户手册说明书

DDSU666 Single phase electronicenergy meter user manual1.Overview of products 1.1 Applicable rangeThe DDSU666 meter mainly applied into the measurement and display for the photovoltaic system parameters in the electric circuit including voltage, current, power, frequency, power factor, active energy, etc. The network can be realized through RS485 communication interface and external device. Adopting the standard DIN35mm din rail mounting and modular design, it is characterized with small volume, easy installation and easy networking.1.Overview of products1.2 Specification for product model1.3 Outline & Mounting DimensionFigure 1.1 Configuration2.Datasheet3.Instructions for installation 3.1 Check the PackageCheck whether the product shell in the carton is damaged, if is, please contact the supplier3.2 InstallationDirectly clip the instrument on the rail and install it on the distribution box.(1)When installing, firstly clip one terminal of the slot and then clip to the rail with power. (standard DIN35mm) (2)When disassembling, press the movable card with a screwdriver and take out the instrument.Figure 3.1 Meter installation3.3 Instruction of wiring terminalFigure 3.2 Direct connectionFigure 3.3 Meter connection diagram3.4 RS485 interface of inverterFigure 3.4 RS485 pinTable 3.1 RS485 pin port definition4.Fault and troubleshooting5.Displayed functionsWhen the energy meter is in normal working condition (on loadstate), the positive pulse indicator should be flashed. If long time for no flashing or light for the indicator, please check whether the wiring mode of the energy meter is right or not.Table 5.1 LCD logo meanings6.Export limitation function settingThe steps for matching R5 series inverters are as follows: (1)Download eSolar O&M APPWeb to eSolar website https:// to scan the QR code and download “eSolar O&M” APP (or download it from Google Play or App Store by searching “eSolar O&M”). After the installation on your phone, please login it with your installer account.(2)Log in APP→ Click “My” → Click “Remote control” → Click “WiFi” /“Bluetooth”→ Click “Next step”. as shown in Figure6.1. Please refer to WiFi/GPRS/4G module manual for detailed connection operation.(3)Enter “local connect” page and select “Export limitation setting” → input password :201561 as shown in Figure6.2.Figure 6.1 Local connect Figure 6.2 Export limitation setting(4)Turn on “export limitation ”, Wait for 15s countdown seconds to set successfully ,supply the power mode and current mode ,as shown in Figure6.3 and Figure6.4Figure6.3 Countdown interface Figure6.4 Power limit/Current limit settingNote:1.Power mode and current mode could be alternatively selected;2.The setting parameter cannot exceed the given range value3.When the setting is completed, the export limitation system will begin to run.。

正泰电能表DDS666(485)单相电能表使用说明书

正泰电能表DDS666(485)单相电能表使用说明书

正泰电能表DDS666(485)单相电能表使用说明书
1.产品特点:
(1)采用3位半数码管,显示直观,具有放大系数和档系数自动换档;
(2)数字式滤波技术,具有抗干扰能力较强;
(3)计量准确,从0.1A到20A的量程均为一级精度;
(4)压力与负荷能力强。

2.技术参数:
(1)额定电压:220V或110V;
(2)额定电流:1.5(6)A、2.5(10)A、5(20)A、10(40)A、
15(60)A、20(80)A、30(100)A;
(3)频率:50Hz或60Hz;
(4)脉冲常数:6400imp/kWh或3200imp/kWh;
(5)温度范围:-25℃~+55℃。

3.使用方法:
可安装在户外式、配电柜式和铁箱式电能表中,使用时应注意保持电表的清洁、干燥和通风。

在接线过程中,应将电表的相序正确地安装,防止相序接反而导致测量不准确。

在使用电表时,还应避免高温、潮湿或冷却水直接喷射等特殊情况。

4.注意事项:
(1)使用电表前,要认真阅读《使用说明书》;
(2)使用过程中应顺手顺序牢记,避免出现接反等情况;
(3)请勿拆卸电表,以免影响电表的使用寿命和计量准确度;
(4)如需进行校验,请到相关的计量单位进行标准电表核验,以检验电表的准确性和是否符合计量标准的要求。

正泰集团DDSY666型电子式预付费单相电能表使用方法及检修办法

正泰集团DDSY666型电子式预付费单相电能表使用方法及检修办法

正泰集团DDSY666型电子式预付费单相电能表使用方法及
检修办法
傅佃斌
【期刊名称】《电工技术》
【年(卷),期】2009(000)006
【摘要】@@ 0 引言rn我单位宿舍区在2005年电路改造中全部使用了DDSY666型电子式预付费单相电能表.该电表自身耗能少,计量准确,避免了住户拖欠电费的现象,大大节省了每月抄表、报表的人力和时间,提高了工作效率.现将该电表的功能与特点、使用方法以及近年来出现的故障等介绍如下.
【总页数】1页(P71)
【作者】傅佃斌
【作者单位】山东省桓台县人民医院,山东,桓台,256400
【正文语种】中文
【中图分类】TM93
【相关文献】
1.DDSY45型预付费单相电能表设计特点的分析 [J], 廖蔚青;汤天顺
2.一起DDYS22D4型电子式单相预付费电能表由于过电压引起的功能失效原因浅析 [J], 沈幼昌;沈青
3.ZQZA型自动站采集器检修及调试软件使用方法 [J], 周枫;邹蓓;董立亭
4.雀之灵ZDK—Ⅳ型磁浮子式全自动开水器电路原理与检修 [J], 薛淑蓉
5.JJC检修列V型天窗作业防感应电伤害措施 [J], 王涛
因版权原因,仅展示原文概要,查看原文内容请购买。

浙江正泰仪器仪表有限责任公司DDSU666系列单相电子式电能表(导轨)使用说明书

浙江正泰仪器仪表有限责任公司DDSU666系列单相电子式电能表(导轨)使用说明书

DDSU666系列单相电子式电能表(导轨)使用说明书ZTY0.464.922浙制00000205号浙江正泰仪器仪表有限责任公司二0一六年八月目录1.概述 (1)2.工作原理 (2)3.主要技术性能与参数 (3)4关键零部件采用 (4)5.主要功能 (5)6.外形及安装尺寸 (11)7.安装及使用说明 (12)8.常见故障的诊断、分析、排除方法 (13)9.运输与贮存 (14)10.保修与服务 (14)DDSU666系列单相电子式电能表(导轨)ZTY0.464.922使用说明书共15页第1页1.概述1.1主要用途及适用范围DDSU666系列单相电子式电能表(导轨)(以下简称“仪表”)根据电力系统、通信行业、建筑行业等电力监控和电能计量需求而设计,为新一代智能仪表,集测量、通讯于一体,主要用于电气线路中电压、电流、功率、频率、功率因数、有功电能等电参量的测量与显示。

可通过RS485通讯接口与外部装置实现组网;采用标准DIN35mm导轨式安装,结构模数化设计,具有体积小、易安装、易组网等优点;广泛应用于工矿企业、宾馆、学校、大型公建内部电能考核与监测。

符合的标准:GB/T17215.321-2008《交流电测量设备特殊要求第21部分:静止式有功电能表(1级和2级)》DL/T645-2007《多功能电能表通信协议》1.2产品特点1)计量正反向有功电能,反向电能按正向累计;2)采用温宽型LCD;3)DIN35mm标准导轨式安装,结构模数化设计,体积小、易安装、易组网。

资料来源编制<**设计签字**><**设计签字日期**>校对<**校对签字**><**校对签字日期**>审核<**审核签字**><**审核签字日期**>标准化<**标准化签字**><**标准化签字日期**>提出部门审定<**审定签字**><**审定签字日期**>标记处数更改文件号签字日期职责签字日期1.3型号组成及代表意义图1型号组成1.4使用环境条件规定的工作温度范围:-25℃~+55℃;极限的工作温度范围:-40℃~+70℃;相对湿度(年平均):≤75%;大气压:86kPa~106kPa。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

(带RS485通讯接口)
1、概述
正泰牌DDS666型单相电子式电能表系我厂最新产品,按GB/T17215-2002标准进行生产,用于测量额定频率为50Hz,参比电压为220V单相交流有功电能。

该产品采用计量电能的专用大规模集成电路和SMT技术,以确保计量准确度度和可靠性,为使停电后数据不丢失,使用步进电机计度器。

产品特点:
产品全部采用性能稳定、功耗低的工业级元器件,运用工艺精心设计制造。

外壳采用阻燃聚碳酸酯,具有很强的抗机械冲击能力。

具有RS485通讯功能,通讯规约满足DL/T645-1997标准的要求。

型号规格
产品型号为DDS666,规格见表1:
表1
使用环境条件
温度范围
规定的工作温度范围:-25℃~55℃;
工作极限温度范围:-40℃~70℃。

相对湿度年平均小于75%时本机可正常工作。

安全性能
本产品符合:
GB/T 耐热和阻燃试验要求。

GB/T 17215-1998 规定的脉冲电压试验和交流电压试验要求。

GB/T 规定的静电放电抗扰度试验要求;
GB/T 规定的高频电磁场抗扰度试验要求;
GB/T 规定的快速瞬变脉冲群试验要求;
GB/T 规定的雷击浪涌试验要求。

2.产品的结构特征与工作原理
结构
本产品的结构设计合理美观,工艺性好,维护方便。

表内功能板、和标牌全部经过合理的设计,采用了卡式安装,可靠方便;功能板是密封安装在有阻燃功能和较高的机械强度的外壳内,保证仪表在GB/T 17215-2002 标准规定的防尘和防水条件下,能够正常工作。

注:S+、S-为测试脉冲输出端,测试脉冲信号采用光耦隔离。

工作原理
本机采用美国模拟器件公司(ADI)生产的ADE7755芯片计量单相有功电能,
通过电阻分压网络和分流元件分别对电压信号和电流信号采样,送到ADE7755电
能计量芯片,在ADE7755内部经过差分放大、A/D转换和乘法器电路进行乘法运算,完成被计量电能的瞬时功率测量;再通过低通滤波和“数字/频率”转换器,输出与被计量电能平均功率成比例的频率脉冲信号,其中高频脉冲输出可供校验使用,低频脉冲输出给计度器显示电量及CPU进行通讯抄收等数据处理;
3、技术特性
主要性能
计量功能:本机可计量正、反向有功电能,反向电能按正向累计;
输出功能
本机采用无源隔离型电量脉冲输出接口,脉冲输出波形为方波;
本机具有电量脉冲输出指示,采用红色LED指示;
RS485通讯功能
电能表可使用掌上电脑通过RS485通讯的方式对电能表进行表号设置、电量底度设置和抄收当前电量等功能。

还可以存储电量。

主要参数
电压
参比电压Un=220VAC,正常工作电压范围为~
电流:见表1
参比频率:50Hz
准确度等级:级和级
基本误差:见表2
功率消耗
电压线路
在参比电压、参比温度和参比频率下,电压线路的有功功率和视在功率不超过1W和7VA;
电流线路
在基本电流、参比频率和参比温度下,电流线路的视在功率不超过1VA;
起动与潜动
起动:在参比电压、参比频率和COSΦ=的条件下,负载电流为时,电能表能连续计量电能;
潜动:在电压回路加115%Un,电流回路断开时,本机不会产生多于一个的脉冲。

4、尺寸重量
外形尺寸为:155mm×110mm×59mm;
安装尺寸为:×91mm;
图4。