施耐德p341000说明书

合集下载

施耐德电气 Easy UPS 3S 10-40 kVA 操作说明书

施耐德电气 Easy UPS 3S 10-40 kVA 操作说明书
维护 .............................................................................................................40
部件更换 ..................................................................................................40 确定是否需要更换部件 ........................................................................40
带内部电池和模块电池柜的 UPS 的推荐设置 ........................................34 设置生命周期监控..................................................................................... 36 设置......................................................................................................... 37
目录
10-40 kVA
重要安全说明- 请妥善保存这些说明 ......................................................5
电磁兼容性.................................................................................................6 安全注意事项 .............................................................................................6

施耐德培训_Modicon_M340__串行通讯.

施耐德培训_Modicon_M340__串行通讯.
纵向冗余校验longitudinalredundancycheckingseriallinecommunication20060524e处理器内置接口seriallinecommunication20060525内置串行通讯接口的处理器模块?处理器模块bmxp34100020102020?led显示面板1run和err表示模块状态sercom表示串行端口状态?集成的串行通讯端口2modbus字符串?黑色的串行接口标记3123seriallinecommunication20060526串行通讯的可视化led诊断?led指示灯不同的颜色及闪烁方式表示串行通讯端口的运行状态模式绿色闪烁红色闪烁黄色闪烁熄灭指示灯runerrsercom含义模块正在运行模块正在自检模块或系统错误配置错误或软件故障正在数据通讯当前无数据通讯seriallinecommunication20060527f串行端口设置seriallinecommunication200605281串行通讯端口设置?打开项目浏览器中的配置文件夹双击机架图标1?双击处理器模块中的串口图标打开串口通道配置端口2?在功能下拉菜单中选择通讯模式332seriallinecommunication20060529通讯参数配置窗口配置参数模式选择
字符串模式调试界面
通讯错误 计数
Serial line communication – 2006/05 34
G – 编辑通讯程序
Serial line communication – 2006/05 35
M340服务器模式下支持的功能码
Function code
01 02 03 04
Memory address
Serial line communication – 2006/05 37

施耐德 APC Back-UPS CS 1000 BK1000Y产品 说明书

施耐德 APC Back-UPS CS 1000 BK1000Y产品 说明书

Back-UPS CS 1000®11 电源开关+工作指示灯2 四个电池后备兼浪涌保护插座3断路开关®990-2489美国APC公司版权所有2006安全信息-请保存本安全指导包含APC 设备与电池之安装和维护的重要指示,供客户在设置、安装、移动和维修APC 设备时遵照使用。

未经APC 明确同意而对设备作改动,可能使保修服务失效。

操作安全<18千克(<40磅)32-55千克(70-120磅)18-32千克(40-70磅)>55千克(>120磅)>10º小心!电气安全在危险条件下,请勿单独一人工作。

高的短路电流流过导电物质时可以造成严重烧伤。

请检查电源线、插头及插座是否完好。

只有合格的维修人员才可更换UPS 上的插头或安装永久性连接设备。

当不能确定接地情况时,为了减少触电的危险,在安装设备或与其他设备连接前,应将设备与交流电源断开。

只有当所有的连线都接好以后,才能重新接通电源。

接触任何金属接头前,务必断开电源。

连接设备时,应采用三线交流接线(两条火线,一条地线)。

插座应连接于合适的支线(或干线)保护装置(保险丝或断路器)。

采用其他类型的插座可能导致触电危险。

只230V 型号:为遵照欧洲之EMC 规定,与UPS 连接之输出电线长度不得超过10米。

只230V 型号:对于插入式A 类设备,UPS 和连接设备的总泄漏电流不得超过3.5毫安。

小心!消电安全(Deenergizing )如果设备带有内部电源(电池),即使该设备未与交流电源相连,其输出端也可能带电。

为了对插入式UPS 消电,首先按OFF 按钮将设备关闭,然后将设备与交流电源断开。

断开外部电池及内部电池(参见用户手册),按ON 按钮以消去电容器的储蓄电能。

为了对永久连接式UPS 消电,首先按OFF 按钮将设备关闭,然后关闭向UPS 供电的交流电断电器。

断开外部电池及内部电池(参见用户手册)。

M340与ATV31的Modbus串行通信(Modbus通信控制启停、Modbus通信给定速度)_完全通信指导资料

M340与ATV31的Modbus串行通信(Modbus通信控制启停、Modbus通信给定速度)_完全通信指导资料

M340与ATV31Modbus串行通信向导<一> ——Modbus通信控制启停、Modbus通信给定速度本向导分为两部分:1.《快速操作指南》---Know How, 满足了客户“快速解决调试问题”的需求。

●发送快---大小在2M左右,能方便快速地通过电子邮件发给客户使用●调试快---提供了反复调试过的完整准确的PLC通信程序,客户可直接下载●接线快---含有实物照片的通信接线图使客户非常容易理解和模仿,并且快速完成接线●设置快---图形化的变频器参数设置指导使客户可直接上手设置参数,不用查找手册2.《完全通信指导》---Know Why, 满足了客户“系统学习通信知识”的需求。

●知识全---不仅给出了详细的调试步骤和详细解释,还使客户在完成通信的同时系统学习相关的产品和通信知识●考虑全---对客户调试可能遇到的各种突发情况给出了相关提示和解决方法●理解易---提供了程序指令和结构的详细注释,使客户能容易的理解和学习提供的标准程序并能在原有程序上进行扩展第二部分完全通信指导重要信息注意:在尝试安装、操作或调试设备之前,请仔细阅读下述说明并通过查看来熟悉设备。

下述特别信息可能会在文本其他地方或设备上出现,提示用户潜在的危险和注意事项,或提供阐明或简化某一过程的信息。

遵守使用说明,可能导致调试失败、人身伤害甚至设备损坏。

此符号的注意事项,以避免不必要的调试错误。

目录1.实验简介 (4)2.硬软件环境 (4)3. ATV31变频器设置 (5)3.1 操作说明 (5)3.2 参数设置 (6)3.2.1 控制方式 (7)3.2.2 通信参数 (8)4. 硬件连接 (10)5. PLC编程 (11)5.1硬件组态 (11)5.1.1 组态CPU (11)5.1.2 组态Modbus Master (12)5.2 ATV31 Modbus变量说明 (12)5.2.1 ATV31 Modbus内部字 (12)5.2.2 ATV31 DRIVERCOM流程 (14)5.3 通信功能块 (15)5.3.1 连续读功能块READ_VAR (16)5.3.2 连续写功能块WRITE_VAR (17)5.4 编程 (18)5.4.1 时间令牌设置 (18)5.4.2 读写从站寄存器 (19)5.4.3 DRIVERCOM流程 (20)6. 实验调试 (21)6.1 计算机与PLC的连接 (21)6.2 软件调试 (22)6.3 ATV31常见通信故障 (23)7. 带多台变频器 (25)7.1 硬件连接 (25)7.1.1 分配器模块和RJ45连接器 (25)7.1.2 接线盒方式 (25)7.2 软件扩展 (26)8. 附件 (28)8.1 M340示例程序 (28)8.2 ATV31的Modbus用户手册 (28)8.3 ATV31编程手册 (28)1.实验简介PLC通过Modbus监控变频器的运行是工业中较常见的应用,本文以施耐德M340 PLC与ATV31变频器为例,简要介绍PLC与变频器之间Modbus串行通信的过程,包括硬件接线、变频器参数设置、硬软件组态、上电调试等,实现在PLC上远程控制ATV31变频器的故障初始化,启动/停止,正转/反转,频率给定等。

施耐德PLC检维修手册

施耐德PLC检维修手册

施耐德P L C检维修手册(总12页)-CAL-FENGHAI.-(YICAI)-Company One1-CAL-本页仅作为文档封面,使用请直接删除施耐德可编程控制器检维修规程1 主题内容及适用范围本规程规定了施耐德公司可编程序控制器运行状态维护检修的具体要求。

本规程适用于施耐德premium可编程序控制器的运行维护检修。

2 引用标准JHBM104.014吉林石化公司自动化仪表管理办法施耐德公司premium可编程序控制器的相关技术资料3 编制本规程目的为了加强premium可编程序控制器的巡检、运行、维护、检修管理,为专业人员提供工作指南,增强工作可靠性、针对性,特制定本规程。

4 概述4.1 系统概述premium可编程控制器采用模块化设计,不同模块可灵活组合。

一个系统可包括:·电源模件(PS):将premium连接到120/230V AC或24VDC电源上。

·中央处理单元(CPU):有多种CPU可供用户选择。

·数字量输入和输出(DI/DO)和模拟量输入和输出(AI/AO)的信号模件(SM)。

·通讯处理器(CP):实现总线连接和点到点连接。

·功能模件(FM):专门用于计数、定位、凸轮等控制任务。

4.2 环境技术标准4.2.1 对系统供电要求·标称电压:120/240V AC;允许范围:90~140V AC/190~264V AC。

·标称频率:50/60Hz;允许范围:47~63Hz。

4.2.2 对接地要求·主参考地接地电阻:<0.1Ω/30A/2min。

·主参考接地要求单点接地:各个接地棒之间的距离要求大于3m;接地线径要求大于5.2mm。

4.2.3 环境条件4.2.3.1 施耐德系统模板对脉冲状干扰的EMC响应见表1。

4.2.3.2 施耐德系统模板对正弦干扰的响应见表2。

4.2.3.3 运行环境的气候条件见表3。

Schneider Electric XU2S18PP340WDR光电门接收器数据手册说明书

Schneider Electric XU2S18PP340WDR光电门接收器数据手册说明书

T h e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d /o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n .T h i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s .I t i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f .N e i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n .Product data sheetCharacteristicsXU2S18PP340WDRlight curtain receiver XU2-S - detection of body- 750..1200 mm - 12..24 VProduct availability: Non-Stock - Not normally stocked in distribution facilityMainRange of product Preventa Safety detectionProduct or component typeSafety thru-beam receiver photo-electric sensors Device short name XU2S Product compatibility XPSCM1144P XPSCM1144Output type1 safety outputs OSSD PNP [Sn] nominal sensing distance26.25 ft (8 m)ComplementaryDetection system Transmitter-receiver system[Us] rated supply voltage 12...24 V DC 10...30 V)against reverse polarity Current consumption <= 35 mA no-load Line of sight type 90° to case axisElectrical connection 1 male connector M12, 4 pins Tightening torque 212.42 Lbf.In (24 N.m) fixing nut 17.70 lbf.in (2 N.m) connector Marking CEMaterial Nickel plated brass casePMMA (polymethyl methacrylate) lenses Net weight0.18 lb(US) (0.08 kg)EnvironmentAmbient air temperature for operation -13…131 °F (-25…55 °C)Ambient air temperature for storage -40…158 °F (-40…70 °C)IP degree of protection IP67 EN/IEC 60529Shock resistance 30 gn 3 axes : 3 times EN/IEC 60068-2-27Vibration resistance7 gn 10…55 Hz)EN/IEC 60068-2-6Ordering and shipping detailsCategory22477 - SAFETY MODULES (PREVENTA)Discount Schedule SAF2GTIN03389110106299Package weight(Lbs)0.29 kg (0.65 lb(US))Returnability No Country of originFROffer SustainabilitySustainable offer status Green Premium productREACh Regulation REACh DeclarationEU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)EU RoHS Decla-rationMercury free YesRoHS exemption information YesEnvironmental Disclosure Product Environmental ProfileCircularity Profile End Of Life InformationContractual warrantyWarranty18 monthsDimensions DrawingsDimensions(1)LED(2)PotentiometerConnections and SchemaWiring Schemes (3-wire DC)ReceiverLight switching (no object present). PNP outputDark switching (no object present). PNP outputConnector Pin View(1)(+)(2)Programming (3)(-)(4)OutputConnecting to a Safety Module1 :Click on Download & Documents2 :Click on System user guideTo have all connection schematics concerning our safety module, select "download and document" and download the file "Connecting to a monitoring device XU2S"Performance CurvesCurvesInfrared Detection Curve(1)Ø of beamVerification of Correct Operation(1)LED off(2)LED on(3)Red LED(4)Signal level(5)Optimum alignment。

M340与ATV71的Modbus串行通信(Modbus通信给定速度、数字量输出控制启停)_完全通信指导

M340与ATV71的Modbus串行通信(Modbus通信给定速度、数字量输出控制启停)_完全通信指导
2.《完全通信指导》---Know Why, 满足了客户“系统学习通信知识”的需求。
知识全---不仅给出了详细的调试步骤和详细解释,还使客户在完成通信的同时系统学习相关 的产品和通信知识
考虑全---对客户调试可能遇到的各种突发情况给出了相关提示和解决方法 理解易---提供了程序指令和结构的详细注释,使客户能容易的理解和学习提供的标准程序并
变频器会自动停止输出并在液晶显示器上显示故障起因故障现象解决方案恢复运行变频器显示变频器输出硬件线路故障slf1约10秒出frqset保持约10秒后停止输出frqset保持后停止输检查并恢复硬件线路通信自动恢复fault1复位rstfault1plc断电plc重新热启动通信自动恢复fault1复位rstfault1plc热启动如10秒内不能启动则停止输出frqset保持约10秒后停止输出frqset保持立即停止输出变频器复位frqset清零通信自动恢复fault1复位rstfault1cpu停止运行plc启动通信自动恢复fault1复位rstfault1通信自动恢复plc冷启动rdy就绪plc冷启动10秒为atv71变频器modbus超时的出厂设定值即在10秒之内如果没有检测到modbus请求或接收信号会报slf1故障
注意
“注意”表示需要注意的操作,如果不遵守,可能导致调试失败。
M340 与 ATV71 的 Modbus 串行通信向导
2
施耐德技术服务中心 TSC
目录
1.实验简介 ........................................................................ 4 2.硬软件环境 ......................................................................4 3. ATV71 变频器设置 ................................................................5

施耐德 APC SMV系列750, 1000, 1500, 2000, 3000 VA说明书

施耐德 APC SMV系列750, 1000, 1500, 2000, 3000 VA说明书

Important Safety InstructionsSAVE THESE INSTRUCTIONS - This manual contains importantinstructions that should be followed during installation and maintenance of the Easy UPS and batteries.Read these instructions carefully and look at the equipment to becomefamiliar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure.The addition of either symbol to a “Danger” or “Warning” safetylabel indicates that an electrical hazard exists which will resultin personal injury if the instructions are not followed.This is the safety alert symbol. It is used to alert you to potentialpersonal injury hazards. Obey all safety messages that followthis symbol to avoid possible injury or death.Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VA2Product Handling GuidelinesSafety and General InformationGeneral safety• Adhere to all national and local electrical codes.• This UPS is for indoor use only. To prevent the risk of fire or electric shock, install in temperature and humidity controlled indoor area, free of conductive contaminants.Easy UPS must be installed indoor with controlled environment free of excessive dust, corrosive air or conductive dust. Keep out of direct sun light, water and heat sources.• Place the unit on the stable floor.• Be sure that the mains socket outlet that supplies the UPS is installed near the UPS and easily accessible. Avoid using extension cords.• UPS must be connected to an earthed mains socket outlet.• Connect the power cable directly to a wall outlet. Do not use surge protectors or extension cords.• CAUTION : This UPS is designed to satisfy the requirement of PCs only.• Do not connect printers, heaters, or copiers to the UPS.Battery safety<18 kg <40 lb 18-32 kg 40-70 lb 32-55 kg 70-120 lb >55 kg >120 lb• Servicing of user replaceable batteries should be performed orsupervised by personnel knowledgeable about batteries and requiredprecautions.NOTE: In this case batteries are not user replaceable.• When replacing battery the UPS must be off, and its AC inletunplugged.• CAUTION: Do not dispose of batteries in a fire. The batteries mayexplode.• CAUTION: Do not open or mutilate batteries. Released material isharmful to the skin and eyes and may be toxic.• CAUTION: A battery can present a risk of electrical shock and burns byhigh short-circuit current. Contact with any part of a grounded batterycan result in electrical shock. The following precautions should beobserved when working on batteries.–Remove watches, rings or other metal objects.–Use tool with insulated handles.–Wear rubber gloves and boots.–Do not lay tools or metal parts on top of batteries.–Disconnect the charging source prior to connecting or disconnectingbattery terminals.–Determine if battery is inadvertently grounded. If inadvertentlygrounded, remove source from ground. Contact with any part of agrounded battery can result in electrical shock. The likelihood of suchshock can be reduced if such grounds are removed during installationand maintenance.• CAUTION: The UPS contains internal batteries and may present ashock hazard even when disconnected from AC power.• CAUTION: Battery circuit is not isolated from AC input, hazardousvoltage may exist between battery terminals and ground. Test beforetouching.• CAUTION: Failed batteries can reach temperatures that exceed theburn thresholds for touchable surfaces.Radio Frequency WarningThis is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to take additional measures.Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VA3Package Contents4Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VARear Panel FeaturesEasy UPS SMV Series 750, 1000, 1500, 2000, 3000 VA5Front Panel FeaturesFront panel display6Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VAEasy UPS SMV Series 750, 1000, 1500, 2000, 3000 VA7Start UpConnect batteryThe battery connector is located on the rear panel. Refer to “Rear Panel Features” on page 5 for details.NOTE : Connect prior to operation.Disconnect prior to transportation. Turn off the UPS and remove input power cable before disconnecting the battery connector. Connect equipment and input power to Easy UPS1. Connect equipment to the battery backup outlets of Easy UPS.2. Plug the Easy UPS power cord directly into a wall outlet, not into asurge protector or power strip.3. Press the POWER ON /OFF button to turn on the unit.NOTE : The Easy UPS should charge the battery for at least 8 hours to ensure sufficient runtime.4. Press the POWER ON /OFF button in 1~3 seconds. Confirm that theEasy UPS is on and is providing power to outlets.Cold start the UPSUse the cold start feature to supply power to connected equipment from the UPS batteries when the UPS is off and there is no power utility.• Press the POWER ON /OFF button. The display panel will illuminate.• Press the POWER ON /OFF button again to supply battery power to the connected equipment.Connect and install management softwareEasy UPS is provided with management software forunattended operating system shutdown, UPSmonitoring, and UPS settings.Refer to for more information. SpecificationsModel SMV750I-MSX SMV1000I-MSXSMV1500AI-MSXSMV2000AI-MSXSMV3000AI-MSXInput SpecificationsVoltage220/230/240 V ACVoltage range165-290 V AC ± 5 V AC165-295 V AC ± 8 V AC Fuse8 A8 A12 A20 A25 A Frequency range45-65 Hz (auto sensing) ±1 HzOutput specificationsUPS capacity (total)750 V A/525 W1000 VA/700 W1500 V A/1050 W2000 V A/1400 W3000 V A/2100 WRated voltage230 VAC Transfer time Typical 2-6 ms, 12 ms max. Waveform Pure Sinewave BatteryType (Maintenance-free Lead acid)12 V /7 Ah x 212 V /7 Ah x 212 V /10 Ah x 212 V /7 Ah x 412 V /9 Ah x 4Charging time4-6 hours recover to 90% capacity PhysicalDimension (D x W x H)410 x 160 x 220 mm(16.1 x 6.3 x 8.7 in)455 x 180 x 240 mm(18 x 7.1 x 9.4 in)Weight withoutpackage13.6 kg17.8 kg23.5 kg25.2 kgPackaging Dimension (D x W x H)508 x 272 x 339 mm(20 x 10.8 x 13.3 in)604 x 319 x 414 mm(23.8 x 12.5 x 163 in)Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VA8Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VA 9Audible Indicators and Status IconsTroubleshootingUse the table below to solve minor installation and operation problems.ModelSMV 750I-MSX SMV 1000I-MSX SMV 1500AI-MSX SMV 2000AI-MSX SMV 3000AI-MSX Weight with package 16.6 kg20.75 kg26.9 kg28.9 kgEnvironment Operating,temperature and humidity 0-90% RH @ 0-40 °C (non-condensing)0-95% RH @ 0-40 °C (non-condensing)Noise level < 45 dB International Protection CodeIP20Problem and/or Possible Cause SolutionEasy UPS will not turn on The Easy UPS is not turned on.Press the POWER ON /OFF button to turn on the Easy UPS.The Easy UPS is not connected to AC power, there is no AC power available at the wall outlet, or the AC power is experiencing a brownout or over voltage condition.Be sure that the power cord is securely connected to the utility power outlet and AC power isavailable at the utility power outlet. Check that the wall outlet is switched on or input fuse works properly.10Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VAServiceIf the unit requires service, do not return it to the dealer. Follow these steps:1. Review the Troubleshooting section of the manual to eliminate commonproblems.2. If the problem persists, contact APC by Schneider Electric CustomerSupport.a.Note the model number and serial number and the date of purchase.The model and serial numbers are located on the rear panel of theunit.b.Call APC by Schneider Electric Customer Support and a technicianwill attempt to solve the problem over the phone. If this is notpossible, the technician will issue a Returned Material AuthorizationNumber (RMA#).c.If the unit is under warranty, the repairs are free.d.Service procedures and returns may vary internationally. Refer to theAPC by Schneider Electric website for country specific instructions.3. Pack the unit in the original packaging whenever possible to avoiddamage in transit. Never use foam beads for packaging. Damagesustained in transit is not covered under warranty.4. Always DISCONNECT THE UPS BATTERIES before shipping.The United States Department of Transportation (DOT), and theInternational Air Transport Association (IATA) regulations requirethat UPS batteries be disconnected before shipping. The internalbatteries may remain in the UPS.5. Write the RMA# provided by Customer Support on the outside of thepackage.6. Return the unit by insured, pre-paid carrier to the address provided byCustomer Support.Easy UPS SMV Series 750, 1000, 1500, 2000, 3000 VA11© 2020 APC by Schneider Electric. APC, the APC logo, and Easy UPS areowned by Schneider Electric Industries S.A.S., or their affiliated companies. All other trademarks are property of their respective owners.EN 990-9144811/2020WarrantyRegister your product on-line The standard warranty is two (2) years from the date of purchase. SEITstandard procedure is to replace the original unit with a factoryreconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declaresuch a need at first contact with an SEIT Technical Support representative.SEIT will ship the replacement unit once the defective unit has beenreceived by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to SEIT. SEIT pays ground freight transportation costs to ship the replacement unit to the customer.APC by Schneider Electric IT Customer SupportWorldwideFor country specific customer support, go to the APC by Schneider Electric website, .。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

施耐德p341000说明书
施耐德p341000供应高施耐德万高型双电源自动切换开关WATSNB-32/4PCR隔离型双电源自动切换开关是一种由微处理器控制,用于电网系统中网电与网电或网电与发电机电源启动切换的装置,可使电源连续源供电。

系列双电源,当常用电突然故障或停电时,通过双电源切换开关,自动投入到备用电源上,(小负荷下备用电源也可由发电机供电,)使设备仍能正常运行。

常见的是电梯、消防、监控上、照明等。

产品功能:电源自动切换及过载、短路保护等产品性能:切换时间延时可调,动作时间准确
产品特点:搞干扰能力强、精度高、防腐性能好,供电可靠产品结构:体积小,结构紧凑,飞弧短,分断高
电气级别:CB级、PC级
产品极数:2、3、4产品壳架:63、100、160、250、400、630产品电流:1A、2、4、6、10、16、20、25、32、40、50、63、80A100、125、160、200、250、315、350、400、500、630A产品符合标准:IEC60947-
6、GB14048.11
B型(外置式):市电-市电的转换/市电-发电机的转换负荷卸载通信
功能可选完整解决方案。

标准配置型号,定制配置型号/符合IEC和GB标准/通过CCC认证和EMC测试额定电压:690V额定电流:1A-3200A极数:4P机械寿命:8000次短切换时间:
产品特点:
安装性能好,采用双列复合式触头、横拉式机构、微电机预储能以及微电子控制技术,基本实现零飞弧(无灭弧罩)采用可靠的机械联锁和电气联锁采用过零位技术,紧急情况下可强制置零(同时切断两路电源)具有明显通断位置指示、挂锁等功能,可靠实现电源与负载间的隔离。

可靠性高,使用寿命8000次以上机电一体化设计,开关转换准确、灵活、顺畅。

电磁兼容性好,抗干扰能力强,对外无干扰,自动化程度自动电源转换系统
性能描述
符合标准GB14048.11-2008
污染等级Ⅲ级
工作温度-25?℃to+70℃
电器级别CB、PC级
使用类别AC-33B/AC-33iB
获得证书CCC及EMC证书CB级转换开关电器
具备短路及过载保护功能?电流等级1-1600A
执行元件C65微型断路器,NSX、NS塑壳断路器
具备较高的短路分断能力
可配置多种脱扣器,满足不同场所需求
具备高限流特性,经济的选择性PC级转换开关电器
接通、承载,但不用于分断短路电流
电流等级32-1600A
执行原件INT及NSX-NA负荷隔离开关
具备较高短路接通及短时耐受能力优势:功能丰富,性能可靠,连接简便,转换稳定,保护。

双电源转换开关电器(转换开关)将一个或几个负载电路从一个电源转换至另一个电源的电器。

由一个(或几个)转换开关电器和其它必需的电器组成,用于监测电源电路、并将一个或几个负载电路从一个电源自动转换至另一个电源的电器。

电气行业中简称为“双电源自动转换开关”或“双电源开关”。

ATS产品的国标标准定义为由一个(或几个)转换开关电器和其它必需的电器组成,用于检测电源电路,并将一个或多个负载电路从一个电源自动转换到另一个电源的电器.ATS适合应用于建筑领域消防等关键负荷的双电源供应,EPS适合应用于EPS是以解决应急照明、事故
照明、消防设施等一级负荷供电设备为主要目标,提供一种符合消防规范的具有独立回路的应急供电系统。

UPS主要是为IT行业设备提供用电,提供纯净、不间断的后备电源。

柴油发电机供电方式适合应用于在需要长时间后备电源的供电场所与ATS、EPS、UPS配合使用。

相关文档