TH4108Y-变频器远程控制器
台达 TH4108变频器远程控制器说明书

TH4108--变频器远程控制器说明书TH4108VFD--B变频器专用V5.2–00202台达VFD目录1、简介-------------------------------------------------------------------------------------------12、功能特点说明-------------------------------------------------------------------------------13、技术规格及参数----------------------------------------------------------------------------1 3.1变频器远程控制器的型号说明----------------------------------------------------------------------13.2技术规格及参数-----------------------------------------------------------------------------------------24、外观说明-------------------------------------------------------------------------------------34.1M型远程控制器的外观说明------------------------------------------------------------------------34.2A型变频器远程控制器的外观说明----------------------------------------------------------------34.3外型及开孔尺寸-----------------------------------------------------------------------------------------44.4键盘功能说明--------------------------------------------------------------------------------------------44.5LED数码管及指示灯说明---------------------------------------------------------------------------54.6变频器远程控制器操作面板操作-------------------------------------------------------------------55、电气接线说明-------------------------------------------------------------------------------6 5.1M型变频器远程控制器后部的端子定义----------------------------------------------------------6 5.2A型变频器远程控制器后部的端子定义----------------------------------------------------------6 5.3变频器远程控制器后部的端子定义说明----------------------------------------------------------6 5.4M型变频器远程控制器的接线图-------------------------------------------------------------------75.5A型变频器远程控制器的接线图--------------------------------------------------------------------76、操作说明-------------------------------------------------------------------------------------8 6.1变频器的设置--------------------------------------------------------------------------------------------8 6.2变频器远程控制器的参数设置界面说明---------------------------------------------------------10 6.3变频器远程控制器的设定参数项------------------------------------------------------------------116.4变频器远程控制器操作方法-------------------------------------------------------------------------177、选配件说明---------------------------------------------------------------------------------188、维护及质量保证---------------------------------------------------------------------------189、随机附件------------------------------------------------------------------------------------1810、用户注意事项----------------------------------------------------------------------------19工程应用,我们更专业TH41TH41008-M/A 变频器远程控制器说明书变频器远程控制器说明书(台达变频器专用V5.2 –002)1、简介变频器远程控制器是一种远程操作变频器的智能仪表,通过RS485网络远程控制变频器的启动、停止、加速、减速、正反转,并实时显示变频器的设置频率、实际频率等状态信息。
变频恒压供水电脑控制器说明书

HD4000变频恒压供水电脑控制器使用手册目录系统概述 (2)主要性能指标 (2)安装尺寸和接线端子说明 (3)操作面板指示及参数设定说明 (5)恢复系统参数出厂值 (5)参数列表及参数出厂默认值 (6)系统参数功能详细说明 (9)故障显示代码说明 (17)外部输入信号端子说明 (17)系统当前时间的调整 (18)手动临时开机的调整 (18)外部输出端子与部分变频器端子的连接表 (19)4-20mA压力变送器的连接方法 (20)RS485远程通讯接口 (20)一、系统概述HD4000系列微电脑变频供水/补水控制器是专为变频恒压供水系统和锅炉及换热系统补水而设计的电脑控制器,可与各种品牌的变频器配套使用。
具有压力控制精度高、压力稳定、第二消防压力(动压)设定、系统超压泄水自动控制、设定参数密码锁定等多项功能。
二、主要性能指标1.可编程设定多种泵工作方式,最多可拖4台泵循环启动;2.配备RS485远程通讯接口,标准组态软件支持远程通讯;3.液晶汉字显示,参数调整和设定具有密码锁定及保护功能;4.采用人工智能模糊控制算法,设定参数少,控制精度高,双看门狗电路,采用数字滤波及多项抗干扰措施,防止软件跑飞;5.可接无源远传压力表、有源电压及电流型压力变送器;6. D/A输出控制频率电压为DC 0-10V, 也可设定为DC 0-5V;7.具有压力传感器零点和满度补偿功能;8.具有定时自动倒泵和退泵功能,不用的泵可以设定退出循环;9.具有动压、静压(消防压力)设定和控制功能;10.具有缺水自动检测保护功能和外部输入停机保护功能;11.具有超压自动泄水设定和控制功能;12.具有供水附属小泵控制功能,可设定小泵变频或工频模式;13.具有定时自动开、关机控制功能;14.具有小流量水泵睡眠控制功能;15.具有手操器功能,可手动调节输出电压来控制变频器的频率;16.可代替电接点压力表进行上、下限压力控制;17.具有分时分压供水控制功能,最多有六段时间控制;18.具有上限保护压力控制功能,超压自动停泵;19.系统运行状态和故障状态汉字提示,运行状况一目了然;三、安装尺寸和接线端子说明1.控制器外形尺寸: 160mm×80mm×90mm2.控制柜面板开口尺寸151mm×75mm,面板卡入式安装。
远程控制阀门工作原理

远程控制阀门工作原理嘿,咱今儿就来唠唠远程控制阀门这玩意儿的工作原理。
你想啊,这远程控制阀门就好比是一个特别听话的小机灵鬼。
咱在远处动动手指,它就能乖乖地按照咱的指示来行动。
它就像是一个神通广大的小卫士,守护着管道里的流体,该让它们通过的时候就放行,不该通过的时候就坚决拦住。
那它是咋做到的呢?其实啊,它里面有好多精巧的小零件呢!就像是一个小团队在协同作战。
有负责接收信号的,就像耳朵一样,时刻听着远方的命令;有负责执行动作的,就像强壮的胳膊,有力地开关阀门。
比如说,在一个大工厂里,各种管道错综复杂,要是靠人一个个去开关阀门,那得多累啊,还容易出错呢!可这远程控制阀门就不一样啦,你坐在控制室里,舒舒服服地看着屏幕,动动鼠标或者按按按钮,嘿,那边的阀门就听话地工作啦!这多方便呀,就好像你有了千里眼和顺风耳,还能隔空施展魔法一样。
再打个比方,这远程控制阀门就像是一个智能的守门员。
管道就是球门,流体就是球员,远程控制就是教练在指挥。
教练说让谁进就让谁进,不让进的绝对别想溜进去。
而且这个守门员还特别靠谱,不会偷懒,不会开小差,随时都精神抖擞地坚守岗位呢!你说这远程控制阀门是不是很神奇?它让我们的生活和工作变得更加轻松、高效。
不用再大费周章地跑来跑去开关阀门啦,这可真是科技带来的大好处呀!它就像是我们的好帮手,默默地在那里工作,为我们的生产和生活保驾护航。
不管是输送水、气、油还是其他什么东西,它都能精准地控制流量和流向。
这可不是一般的厉害呀!所以啊,可别小看了这远程控制阀门哦,它虽然个头不大,但是作用可大着呢!它让我们的世界变得更加有序、更加便捷。
你想想,如果没有它,那得有多麻烦呀!哎呀,真不敢想象呢!它真的是现代科技的一个小奇迹呀!原创不易,请尊重原创,谢谢!。
SC-8G-BLK 变频器远程手持遥控器说明书

变频器远程手持遥控器使用说明书SC-8G-BLK使用之前请仔细领会产品说明书前言广泛的应用,适合各种不同的工业无线控制化需求SC-8G-BLK型遥控器可适用于绝大部份之应用与操作环境,外型符合人体工学,即使经过长时间腰挂或操作亦不觉苦;同时并俱备多种规格可供选用。
停工愈短,利润愈高拥有一部好的机器,就好比如鱼得水,如虎添翼般得以事半功倍。
SC-8G-BLK遥控器革命性的研发技术,操作力求简单易懂,零件寿命符合长时间恶劣环境要求,令自动化无线控制绩效达到最完美的境界。
工业无线的特色提高生产效能--控制掌握操作者手里,使操作者独特判断,有连贯性,产能自然提高.人力资源减少--减少一名驾驶手操作,使用者可独立挂钩头,一人独立操作,勿须指挥.远离危险区操作--对于高温,强酸,强碱..等,可站在安全且视野良好地方操作.减低制造,维护成本--可完全取代驾驶室功能,让'驾驶室’发挥移动性功能.产品部份:轻巧无线的发射器,外壳采用顶级PA材质,保护达IP65具高度耐冲击,防水和防尘等特性,内藏式和外接天线设计不易受外力折损,搭配腰挂式背带或颈带,使操作更轻松,便利SC-8G-BLK型遥控器是您最聪明的选择。
接收器外壳符合EMC标准,保护达IP67,除防尘防水外更可抗紫外线,可在恶劣环境下安装使用。
内部可计算机做功能设定,并具备多重数字防护,抗干扰性特强,可有效防止误动作产生。
SC-8G-BLK型遥控器大幅缩短了工程师装设的时间。
SC-8G-BLK型遥控器采用欧制高耐用按键,寿命达百万次以上。
发射器使用二颗(AA1.5V)电池,省电且更换容易。
若SC-8G-BLK型遥控器标准型遥控器仍无法满足您的需求,我们亦接受客户特殊要求制做,满足您所需的任何功能。
SC-8G-BLK型遥控器基本配备背挂式发射器1只/接收器1只/使用手册1本/背颈带1条SC-8G-BLK型遥控器选用本配备外加吸盘延长3米线吸盘天线SC-8G-BLK技术数据保护装置:电流突波吸收能力/短路保护/特殊无接地保护发射功率:<10mW混附发射:>60dBc使用电池:AA碱性干电池2只(约可使用1-4个月)安全密码组:亿组工作温度:-10°C∼+70°C反应时间:100mS遥控距离:150公尺(标准品)接点容量:10A使用频率:300/868Mhz-1-电压比例输出:0-10V(配合变频器)天线阻抗:50Ω使用电压:220V调制方式:F1D尺寸:发射器:L224x W65x H45mm接收器(BOX2):L200x W85xH65mm保护等级:发射器:IP65接收器:IP67重量:480g(发射器)/1,430g(接收器)外壳颜色:发射器:黑橙接收器:黑橙安全标准:符合EMC标准SC-8G-BLK安装要领接收机之安装程序十分简单,所需工具如下:尖嘴钳/斜口钳/十字起子/梅花扳手/三用电表/电钻/电缆配线及其材料安装前注意事项(a)请先确定变频器原始线控动作正常。
M-System R7C-RR4 远程控制电磁闸控制模块说明书

BEFORE USE ....Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below .I f you have any problems or questions with the product, please contact M-System’s Sales Office or representatives. ■PACKAGE INCLUDES:Remote control relay control module .................................(1) ■MODEL NO.Confirm Model No. marking on the product to be exactly what you ordered.■INSTRUCTION MANUALThis manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures.POINTS OF CAUTION■POWER INPUT RATING & OPERATIONAL RANGE• Locate the power input rating marked on the product and confirm its operational range as indicated below:24V AC rating: 24V ±10%, 50/60Hz, approx. 100mA 24V DC rating: 24V ±10%, approx. 65mA ■GENERAL PRECAUTIONS• Before you remove the unit or mount it, turn off the power supply and output signal for safety .• DO NOT set the switches on the module while the power is supplied. The switches are used only for maintenance without the power. ■ENVIRONMENT • Indoor use.• When heavy dust or metal particles are present in the air, install the unit inside proper housing with sufficient ventilation.• Do not install the unit where it is subjected to continuous vibration. Do not subject the unit to physical impact.• Environmental temperature must be within -10 to +55°C (14 to 131°F) with relative humidity within 30 to 90% RH in order to ensure adequate life span and operation. ■WIRING• Do not install cables close to noise sources (relay drive cable, high frequency line, etc.).• Do not bind these cables together with those in which noises are present. Do not install them in the same duct. ■AND ....• The unit is designed to function as soon as power is sup-plied, however, a warm up for 10 minutes is required for satisfying complete performance described in the data sheet.COMPONENT IDENTIFICATION(A) Status Indicator LED *1(B) Station Address Setting Rotary SW (C) Baud Rate Setting Rotary SW (D) I/O Status Indicator LED(E) CC-Link, Power Supply Terminals (F) Output Terminals(G) Terminating Resistor SW*1. Refer to ‘Status Indicator LED’ section for detailed information.■FRONT VIEW■ SIDE VIEW■STATUS INDICATOR LED ID COLOR FUNCTION PWR Red Turns on when the internal 5V is sup-plied normally .RUN Red Turns on when the refresh data is re-ceived normally .ERR Red Turns on when the received data isabnormal.SD Red Turns on when the module is transmit-ting.RDRed Turns on when the module is receiving.■STATION ADDRESSStation Address is selected between 1 and 64 in decimal.The left switch determines the tenth place digit, while the right switch does the ones place digit of the address.Station Address Setting (x1)Station Address Setting (x10)056 222 38 18SEN TRONIC AG■BAUD RATEBaud Rate is selected with the rotary switch.Baud Rate Setting■TERMINATING RESISTORTo use the terminating resistor, turn the switch ON, and OFF to invalidate. (Factory setting OFF)■POWER SUPPL Y, CC-LINK TERMINAL ASSIGNMENT4DA 5DG 6U(+)1DB 2SLD 3FG 7V(–)NO.ID FUNCTION, NOTES1DB White 2SLD Shield 3FG FG 4DA Blue 5DG Yellow 6U(+)Power input 7V(–)Power input■OUTPUT TERMINAL ASSIGNMENT10561278934Y3C3NC NC C0Y0Y1Y2C1C2NO.ID FUNCTION NO.ID FUNCTION 1NC No connection 6NC No connection 2C0Common 07Y0Output 03C1Common 18Y1Output 14C2Common 29Y2Output 25C3Common 310Y3Output 3INDICATOR LED■STATUS INDICATOR LED PWRRUNERRSD *1RDSTATUS *2ON ON BL BL ON Communicates normally with occasional CRC errors due to noise interference.ON ON BL BL ONCommunicates normally but the Baud Rate and/or Station Address switches failed. ERR LED blinks approximately in 0.5 seconds intervals.ON ON BL BL OFF ----ON ON BL OFF ON CRC error found in the received data. Unable to respond.ON ON BL OFF OFF ----ON ON OFF BL ON Normal communication ON ON OFF BL OFF ----ON ON OFF OFF ON Unable to receive data addressed to the station.ON ON OFF OFF OFF ----ON OFF BL BL ON Performs the interval-timed responses but CRC error found in receiving the refreshdata.ON OFF BL BL OFF ----ON OFF BL OFF ON CRC error found in the data addressed to the station.ON OFF BL OFF OFF ----ON OFF OFF BL ON Link is not started.ON OFF OFF BL OFF ----ON OFF OFF OFF ON No data addressed to the station. Or unable to receive data addressed to the stationdue to noise interference. (Missing parts of the data sent from the master)ON OFF OFF OFF OFF Unable to receive data due to wire breakdown ON OFF ON OFF ON/OFF Faulty Baud Rate and/or Station Address setting OFFOFFOFF OFF OFF Power input removed. Or power supply failure.OFF = OFF , ON = ON, BL = Blinking*1. SD LED may look not blinking but ON with high baud rate and fewer connected modules.*2. LEDs indicated with “----” in STATUS rarely occurs in normal operation (LED failure or the like as possible cause).■I/O STATUS INDICATOR LEDFeedback input status and output bit status are indicated with LED.ON : LED ON OFF : LED OFFTERMINAL CONNECTIONSConnect the unit as in the diagram below . ■EXTERNAL DIMENSIONS unit: mm (inch)TERMINALS for CC-Link, POWERTERMINALS for OUTPUT■CONNECTION DIAGRAMY0Y1C1Y2C2Y3C3C0DA DB DG SLD FG U(+)V(–)■Output Connection ExampleCaution: FG terminal is NOT a protective conductor terminal.COMMUNICATION CABLE CONNECTIONSMaster UnitRemote Unit Remote UnitBe sure to connect the terminating resistor across DA and DB at both ends of communication line.When this unit is located at an end, turn the terminating resistor SW ON.The Master Unit can be located at not only both ends but also any node of the of communication line.MASTER CONNECTION DATA ALLOCATIONRX(n+0)3 to RX(n+0)0Unused (R7C-RR4)Unused 0F1FInterval-timed Response (X)0F1FRefresh Data (Y)R7C-RR4RY(n+0)F to RY(n+0)8(R7C-RR4)I/O DATA DESCRIPTIONSFeedback input 0Feedback input 1Feedback input 2Feedback input 3Not UsedOutput 3 OFF0: OFF 1: ONOutput 0 ON Output 0 OFFOUTPUT SETTINGEach output is set with 2 bits. Refer to the table below for output setting.NO.BIT SETTING FUNCTIONOutput 08, 90, 0No operation 1, 0Output 0 ON 0, 1Output 0 OFF 1, 1InvalidOutput 110, 110, 0No operation 1, 0Output 1 ON 0, 1Output 1 OFF 1, 1InvalidOutput 212, 130, 0No operation 1, 0Output 2 ON 0, 1Output 2 OFF 1, 1InvalidOutput 314, 150, 0No operation 1, 0Output 3 ON 0, 1Output 3 OFF 1, 1InvalidDo not set both bits 1. If the 2 bits are simultaneously 1, the module will not operate normally.For repeating the output of ON pulse, after setting (0, 0), set (1, 0) once again.WIRING INSTRUCTIONS■SCREW TERMINALTorque: 0.5 N·m■SOLDERLESS TERMINALRefer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Applicable wire size: 0.25 to 1.65 mm2 (AWG 22 to 16) Recommended manufacturer: Japan Solderless TerminalMFG. Co., Ltd, Nichifu Co., Ltd。
宇控yk580变频器说明书

宇控yk580变频器说明书宇控yk580变频器是一种电力变频器,可用于各种工业应用,包括机械传动系统、制造业和物流产业。
本文将对宇控yk580变频器的特点、技术规格、安装和维护等方面进行详细的说明。
1、特点宇控yk580变频器具有以下几个特点:1.1、高精度控制宇控yk580变频器采用空间矢量控制(SVPWM)技术,可以获得高精度的速度和转矩控制。
该技术能够有效降低噪音和无功损耗,提高整个系统的效率和可靠性。
1.2、广泛的应用领域宇控yk580变频器广泛应用于各种电机控制领域,例如,风扇和泵设备、机械传动系统、制造业自动化控制和物流产业。
1.3、多种控制方式宇控yk580变频器支持多种控制方式,包括V/F控制、矢量控制和SVPWM控制。
用户可以根据不同的应用需求选择适当的控制方式。
1.4、智能保护机制宇控yk580变频器具有多种保护机制,包括过温保护、欠相保护、过电流保护以及供电电压异常保护。
当某些故障发生时,变频器会自动停机以避免更严重的损坏。
2、技术规格宇控yk580变频器的技术规格如下:2.1、输入电源电压:三相 380V/220V± 15%频率:50/60 Hz ± 5%2.2、输出功率及电流输出功率:0.75 KW - 315 KW输出电流:1.9 A - 630 A2.3、控制方式V/F控制、矢量控制、SVPWM控制2.4、保护机制过温保护、欠相保护、过电流保护、供电电压异常保护2.5、环境要求环境温度:-10 ℃ - 40 ℃相对湿度:<90%2.6、其他控制精度:1%输出频率:0 - 400 Hz3、安装步骤在安装宇控yk580变频器前,需要注意以下几个问题:3.1、安装环境安装场所不应该存在影响变频器工作的磁场干扰源,应该确保变频器的通风良好,防止发热。
3.2、布线按照电路图,连接三相电源,电机和外部信号。
在接线之前,请首先断开变频器上的电源。
3.3、接地变频器需要接地保护,确保安全工作。
远程自动控制压力调压溢流阀
收稿日期:2004-02-02 作者简介:刘光恒(1965-)男,天津市人,高级工程师,主要从事高压水射流清洗设备和清洗技术研究。
2004 年第 3 期 1
·2 ·
清 洗 世 界
要,工业清洗越来越被人们重视,并迅速被广泛推广
第 20 卷 · 11
和应用。现在高压水射流清洗技术已经成为工业清洗
Abstract The author of this thesis have successfully developed a remote autocontrol pressure-regulating overflow valve, which is installed on high pressure water jet to accomplish its remote pressure control and regulation. And this paper emphatically illustrates this pressure-regulating overflow valve from aspects of operation principle, construction and application examples. Key words high pressure water jet; pressure-regulating overflow valve; electric device
2004 年第 3 期 3
· 第 3 期
3 应自行研制的远程自动控制压力调压溢流阀已 在“G X X T 油田载车清洗系统”中成功得到运用。 GXXT 油田载车清洗系统装备有两台 GS70 型高压水 射流清洗机,每台清洗机安装了一台远程自动控制压 力调压溢流阀,成功实现了成套清洗系统的自动控 制。图 4为安装有远程自动控制压力调压溢流阀的高 压水射流清洗机,图 5 为 GXXT 油田载车清洗系统的 操作控制台。
变频器的远程控制
四川工程职业技术学院毕业设计论文设计题目: 变频器的远程控制专业:作者:日期:指导教师:摘要本设计是一个完整的小型工程项目,变频器的远程控制是利用USS协议实现PLC与变频器之间的通信,完成远程控制。
通过PLC外接电位器控制电机,实现无级调速,并在文本显示器上显示和设定电机转速;同时通过PLC 外接按钮或者文本显示器实现电机的启动与停止。
变频器具有调范围宽、精度高、可靠性好、效率高、操作方便和便于与其他设备接口和通信等优点。
随着技术的发展和价格的降低,变频器在工业控制中的应用越来越广泛。
如果用PLC的开关量、模拟量模块与变频器交换信息,存在占用的PLC开关量的I/O点数较多,易引入噪声等;如果用PLC通过通信来监控变频器,那么通信方式使用的接地线少,传送量少,可以连续地对变频器进行监视和控制。
还可以通过通信修改变频器参数,实现多台变频器的联动控制和同步控制。
关键词:变频器;远程控制;USS协议;文本显示器。
AbstractThis design is a complete small projects, inverter remote control is the use of USS Protocol for communication between PLC and frequency converter, through the remote control. Through an external potentiometer control motors PLC to realize stepless speed regulation, and appears on the Text Display and set the motor speed, while an external button or Text Display by PLC starting and stopping of the motor.Inverter incorporates a wide adjustment range, precision, reliability, high efficiency, easy to operate and easy to interface with other devices and communication and so on. As technology advances and prices lower, frequency converter in industrial control applications are widely used.If PLC switch, analog modules exchange information with inverter, PLC switch I/O points occupied by large, easy to introduce noise; if using PLC communication to monitor inverter, communication style, using a grounding wire less, less shipping, continuously monitoring and control of the inverter. Parameters can be modified by the communication frequency converter, achieving more than one linkage control and synchronous control of frequency converter.Keywords: Converter;remote control;USS protocol;Text Display.目录摘要 (I)目录 (III)第1章绪论 (1)1.1课题研究背景和意义 (1)1.2现状与发展及主要工作内容 (1)1.3设计任务及要求 (1)第2章系统总体设计 (2)2.1控制要求 (2)2.2系统组成 (2)2.2.1系统示意图 (2)2.2.2系统框图 (3)2.2.3工作条件 (3)2.3控制方案 (3)2.3.1起停控制 (3)2.3.2调速控制 (4)2.3.3调速模块的切换 (4)2.3.4保护措施 (4)2.4电气原理图 (5)2.5通讯 (5)2.4.1 USS协议 (5)2.4.2 MPI协议 (8)第3章系统的硬件设计 (9)3.1系统的硬件选型 (9)3.1.1 PLC及其扩展模块的选型 (9)3.1.4 空气开关的选型 (9)3.1.5 直流稳压电源的选型 (9)3.2 变频器和文本显示器的简介 (9)3.2.1 MM420变频器 (9)3.2.2 文本显示器 (10)3.2.3 USS通信硬件连接 (10)3.3 控制系统的I/O点及地址分配 (10)3.4系统主电路和控制电路的硬件设计 (11)第4章系统软件设计 (12)4.1 编程软件介绍 (12)4.2 系统软件设计分析 (12)4.3 程序流程图 (14)4.4 程序编写 (14)第5章硬件和软件结合调试 (19)5.1 USS协议与MM420变频器的通信 (19)5.1.1安装指令库 (19)5.1.2编写通讯程序,编译下载程序 (19)5.1.3设置MM420变频器参数,接好电动机 (20)5.1.4连接网络线 (21)5.2联机调试 (21)结论 (22)参考文献 (23)附录 (24)附录一 (24)附录二 (25)第1章绪论1.1课题研究背景和意义计算机及通讯技术已成为工业环境中大部分解决方案的核心部分,其在系统中的比重正在迅速增加。
控制器的远程控制说明书
控制器的远程控制说明书一、概述本说明书旨在向您介绍如何使用控制器实现远程控制功能,以便更加便捷地操作相关设备。
请仔细阅读并按照说明进行操作,确保使用过程中的安全和顺利。
二、远程控制设置1. 首先,确保控制器已经与所需设备正确连接,并处于工作状态。
2. 打开控制器的电源开关,等待系统启动。
3. 进入控制器的设置菜单,根据具体的情况选择“远程控制”选项。
4. 在远程控制设置页面中,选择“添加设备”选项,并按照提示完成设备的添加。
5. 完成设备添加后,返回上一界面并选择“远程控制模式”。
6. 在远程控制模式下,您可以根据需要进行各类操作,如开关设备、调节参数等。
三、远程控制操作1. 打开手机或者电脑的浏览器,输入控制器的远程控制网址。
2. 根据页面提示,输入相应的账号和密码,进行登录。
3. 进入远程控制主页面,您可以看到控制器已添加的设备列表。
4. 选择所需设备,并点击进入设备控制界面。
5. 在设备控制界面,您可以根据设备的功能进行操作,比如开关设备、调节亮度或音量等。
6. 操作完成后,及时保存设置并退出远程控制界面。
四、其他注意事项1. 请确保网络连接的稳定性,以保证远程控制的正常进行。
2. 在操作设备时,请注意设备是否处于安全状态,避免因远程控制而导致意外情况发生。
3. 对于一些复杂的操作或者特殊设置,建议参考具体设备的说明书或联系相关技术支持。
4. 如需取消某台设备的远程控制权限,可以在控制器的设置菜单中进行相应的操作。
五、总结通过本说明书,您应该已经了解了如何使用控制器进行远程控制,并成功完成了相关设备的添加与操作。
在使用过程中,如果遇到任何问题,请及时寻求技术支持或者参考设备的详细说明。
祝您使用愉快!。
基于串口服务器的变频器远程控制系统
wa ea d h r wa e u i gABB i v re ed s r e ih h slW o t W i h sc n g r t n rs u c sc n r a d r sn n et r e c i d whc a O c s . t t i o f u a i . e o r e a n r a b h i o b h e d t e n t r n g me tc l b p e n t e id sr . e s a d a h ewo k ma a e n a e a P id i h u ty r n l l n Ke r s n v r r s r l e ie s r e ; t en t ACS 0 y wo d :i e t ; e i v c e r r E h r e ; e ad 60
网 相 连 , 够 灵 活 方 便 地 实 现 对 变频 器 的 远 程 监 控 。 系 统 软 、 件 结 构 简 单 , 本 低 , 应 了 工 业 现 场 资 能 硬 成 适
源 共 享 与 网络 化 管 理 的 需要 。 关 键 词 : 频 器 ; 口服 务 器 ; 太 网 ; S 0 变 串 以 AC 6 0
W ANG Na, a g-h n L o p n ZHANG n c i AICh n s e g, IGu — i g, Yu - a
( . e t f l t c] nie r g , ia nvr t, i n2 0 2 , hn ;. e ea G o p J a 5 10, hn ) 1 D p .o e r a E g ei E ci n n J nU i sy J a 5 0 2 C ia 2 G n rl ru , i n2 0 0 C ia n ei n n
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
TH4108Y-变频器远程控制器--用户指南目录1、综述 (1)1.1、产品简介 (1)1.2、开箱检查 (1)2、功能特点说明 (1)3、操作面板说明 (2)3.1外观说明 (2)3.2显示区说明 (2)3.3按键和旋钮功能说明 (3)4、外型及开孔尺寸 (3)5、Y型变频器远程控制器后部的端子定义和说明 (4)6、操作说明 (6)6.1变频器远程控制器的参数设置界面说明 (6)6.2变频器的设定参数项 (7)6.3变频器远程控制器的设定参数项 (7)6.4变频器远程控制器操作方法 (11)7、维护及质量保证 (12)8、随机附件 (12)9、用户注意事项 (12)工程应用,我们更专业TH4108AY变频器远程控制器使用指南Version 4.31、综述感谢您购买郑州天宏自动化技术有限公司生产的TH4108系列变频器远程控制器。
由于致力于变频器远程控制器的不断改善,因此本公司所提供的资料如有变更,恕不另行通知,敬请谅解。
1.1、产品简介变频器远程控制器是一种远程操作变频器的智能仪表,可通过RS485网络远程通讯控制变频器的启动、停止、加速、减速、正反转,并实时显示变频器的设置频率、实际频率等状态信息,通讯距离可长达1200米(9600bps),有效减少变频器的干扰。
可接外置操作按钮,便于工程使用。
有手/自动功能(监听功能),便于组成计算机或PLC的自动控制系统。
可接外置操作按钮,便于工程使用。
有手/自动功能(监听功能),便于组成计算机或PLC 的自动控制系统。
1.2、开箱检查在开箱时,请认真确认:产品是否有破损现象;本机是否与您的订货要求一致。
本公司在产品的制造及包装出厂方面,已严格检验,若发现有某种遗漏,请速与本公司或供货商联系解决。
2、功能特点说明2.1 远程控制变频器的启动、停止、正转、反转、递增、递减变频器的频率。
2.2 可禁止变频器反转功能。
2.3 从机监听功能,在监听模式时MON灯亮。
2.4 若变频器有故障,则在故障显示区显示Exxx,表示变频器的故障代码。
2.5 可以用无线的方式和变频器通信(外接无线收发模块TH4070)。
2.6 提供7路DI开关量输入端子,可外接按钮控制变频器启动、急停、正反转、监听等功能。
操作简便、抗干扰、安全可靠。
2.7 提供5路DO开关量输出端子,可控制变频器启动、急停、正反转、监听等功能。
操作简便、抗干扰、安全可靠。
3、操作面板说明3.1 外观说明①液晶屏显示区,常态显示设定值、变频器实际频率、输出电流、输出电压、母线电压、输出功率、输出转矩、故障代码和运行时间等参数,指示变频器的状态;在参数设定状态显示参数项和参数值以及对该参数项的文字说明②按键和旋钮区,有五个按键和一个旋转编码开关。
3.2 显示区说明常态下TH4108Y液晶显示变频器远程控制器的显示屏可划分为5个显示区,常态下的显示区划分:①设定值显示区,显示设定频率或设定转速值②实际值显示区,显示实际频率或实际转速值③输出参数显示区,可显示读取的变频器输出电流、输出电压、母线电压、输出功率、输出转矩和故障代码等数值④运行时间显示区,按下RUN键开始计时,在该区显示运行时间,显示格式为:00:00:00,依次为:小时:分钟:秒 按下STOP 键后运行时间自动清零⑤ 状态显示区,从左至右分别为:运转指示(运转时点亮),反向指示(反向时点亮),监听指示(监听时点亮),故障指示(出现故障时点亮),通讯指示(通讯正常时闪烁,监听状态或通讯异常时不显示图标)3.3 按键和旋钮功能说明4、外型及开孔尺寸(图4-2)变频器远程控制器外形5、Y型变频器远程控制器后部的端子定义和说明(图4-1)Y型变频器远程控制器后部端子定义5.1 端子中的220N和220L是仪表供电电源输入端,接220V交流电。
5.2 端子中的A、B、CGND是RS485通讯接口,连接变频器(只接A和B即能工作,但建议连接CGND到变频器的通讯GND)。
5.3端子中的ADC0、ADC1和ADGND是模拟量输入端子,其中:ADC0:是0-10V电压信号输入正端ADC1:是4-20mA电流信号输入正端ADGND:是模拟量输入信号公共输入负端5.4端子中的DAC0、DAC1和DAGND是模拟量输出端子,其中:DAC0:是0-10V电压信号输出正端DAC1:是4-20mA电流信号输出正端DAGND:是模拟量输出信号输出公共负端5.5端子中的IN0-IN6是7路开关量输入端口,INCOM是公共接点,可以通过按钮开关来对变频器进行控制。
DI开关量输入端内部电路结构是双向光耦,如下图所示:INCOM可以是电源的正端也可以接电源的负端,INx接另一端即可。
推荐的接线方式:TH4108变频器远程控制器的输入公共端INCOM与1号端子POWER 短接,2号端子PGND 外接控制信号线即可实现各开关信号的闭合断开控制。
INx 的定义如下:5.6 端子中的OUT0-OUT4是5路开关量输出端口,OUTCOM 是公共接点,输出开关量控制变频器的启停、正反转、故障复位等。
DO 开关量输出端内部电路结构如下图所示:DO 输出有两种方式:OC 三极管输出和继电器无源输出,在OC 输出模式下可以外接DC 24V 继电器做后极控制。
默认是OC 输出,若需要继电器无源输出时需在电路板上加焊24V 继电器。
其中:OC 三极管输出时,DGND 是DO 输出的公共端子,OUT2是输出正端 继电器输出时,输出端子即COM 和OUTPUT ,无源输出,不分正负。
※ OC 模式下外接DC 24V 继电器的接线方式:TH4108A 的输出公共端OUTCOM 与2号端子PGND 短接,1号端子POWER 接继电器正控制端,OUTx 接继电器负控制端,即可实现对DC 24V 外接继电器的控制。
OUTx的定义如下:6、操作说明6.1 变频器远程控制器的参数设置界面说明6.1.1 参数设定界面:6.1.2 参数项与参数值的显示:①参数项显示区,格式如Cxxx,显示参数项;②参数值显示区,显示左侧参数项的参数值③文字说明区,是对该参数项的文字说明。
6.1.3 切换参数项:递增参数项:顺时针旋转编码开关。
递减参数项:逆时针旋转编码开关。
6.1.4 改变参数值:递增参数值:顺时针旋转编码开关。
递减参数值:逆时针旋转编码开关。
6.2 变频器的设定参数项见附页6.3 变频器远程控制器的设定参数项表中符号说明:X: 参数在运行过程中不能修改;√:参数在运行过程中可以修改;-:无意义;*:只对某种特定的变频器有效,详见变频器参数设置表。
(图6-2)变频器远程控制器参数功能一览表6.4 变频器远程控制器操作方法6.4.1 变频器的启动(RUN):在停车状态,没有故障并且“停止接线端子IN1”没有按下,即变频器远程控制器的外接停止按钮没有压下时,按下RUN键,或按下“运行接线端子IN0”,变频器启动,RUN灯亮。
6. 4.2 变频器的停止(STOP):当RUN灯亮,按下STOP/RESET或“停止接线端子IN1”(即变频器远程控制器的外接停止按钮压下)时,变频器停止。
RUN灯灭。
6.4.3 变频器的正反转(正反转控制接线端子IN2):开关量断开时发送正转指令,开关量闭合时发送反转指令,反转时F/R灯亮。
6.4.4 改变变频器频率:递增频率: 按▲键,或顺时针旋转旋钮。
递减频率: 按▼键,或逆时针旋转旋钮。
6. 4.5 故障的复位:若检测到变频器故障,ERR灯亮,这时按下STOP/RESET键,若在运行状态首先发送停车指令,再次按下STOP/RESET键发送故障复位指令;若不在运行状态则直接发送故障复位指令。
7、维护及质量保证①正常情况下,仪表不需要特别维护,请注意防潮。
②因产品质量问题引起的故障,在出厂12个月内实行三包。
8、随机附件①操作使用指南一份②安装卡子一对③出厂检测报告及合格证一份9、用户注意事项●用户远程连接电缆长度在400m以下时,可选用普通屏蔽4芯电缆屏蔽层本地端接地;●用户远程连接电缆长度在400m至800m时,应选用金属编织网为屏蔽层的两对双绞线屏蔽电缆,屏蔽层双端接地,金属管道可为AWG18号以上线制成的双绞线;●用户远程连接电缆长度在800m至1 公里时,应选用金属端编织网为屏蔽层的多对双绞线屏蔽电缆,屏蔽层必须走线方向多点接地;●多雷雨地区应安装防雷电设施;●用户远程连接电缆与电源功率电缆间距必须操持最少30cm间距,如空间无法分开应使金属隔离物或置于金属管道内,在其走线长度内金属隔离物或管道应多次接地;●用户应尽量减少无用电缆长度;●使用天宏无线模块时,在防止雷击和静电的情况下,一般来说,天线越高则通讯距离越远。
通讯为连续模式,失败概率不高的情况下,一般不影响使用;●请在下述环境下使用,否则可能造成远程控制器故障硬件版本:Version 4.3软件版本:Version 408说明书更新日期:2011-07-25郑州天宏自动化技术有限公司。