电能表的选择

合集下载

西门子9410电能表选择与应用指南说明书

西门子9410电能表选择与应用指南说明书

/PDS9410 | Selection and Application GuideIntroduction and Typical applications 2Features and benefits 3-4Measurements 5-6Installation 7Functions89410 Built-in web pages 9Applications and benefits 10Ordering information11Compact power, energy and power quality metersTypical power and energy management applications using the 9410 MeterThe Siemens 9410 series power meter combines accurate, 3-phase energy and power measurement with data logging, power quality analysis, e-mail, alarming, Modbus Mastering, Waveform capture and extensive I/O capabilities not typically available in a compact meter.Table of Contents22Financial management including accounting and billingPower generation transmission and distributionFacility and energy managementSupports operations management planning and procedures PDUs and RPPsService entrances and onsite generation Tenants, departments or subcontractorsPower mitigation and main power distribution equipmentProcesses, lines, machines or equipment3Selection and Application Guide | 9410Features and benefitsMain real time valuesPower quality main screenWaveformsMin /maxThe 9410 series meters are ideally suited to local and remote monitoring of low or high voltage electrical installations in industrial facilities, commercial buildings, utility networks or critical power environments. Facility and operationspersonnel will benefit in energy-related costs while avoiding power quality conditions that can reduce equipment life and productivity.The 9410 series meter is easy to install and use, offering integrated or remote high-visibility displays. A range of expansion modules help match features to the application and support field-upgrading of meters as required. Serial and Ethernet communication enable the meter to be used within a power management system or with third-party management systems.Benefits• Maximize profits by providing high output with the least amount of risk to availability.• Improve availability and reliability of electrical systems and equipment.• Monitor power quality (PQ) for compliance and to prevent problems.• Meters fully supported by .• Down to one millisecond digital Input event logging.Typical applicationsIndustrial, commercial, and critical power • Energy savings- Measure efficiency, reveal opportunities and verify savings- Sub-bill tenants for energy costs- Allocate energy costs to departments or processes - Reduce peak demand surcharges - Reduce power factor penalties- Leverage existing infrastructure capacity and avoid over-building- Support proactive maintenance to prolong asset life • Energy availability and reliability- Validate that power quality complies with the energy contract- Verify the reliable operation of equipment- Improve response to power quality-related problems For electrical infrastructure• Energy availability and reliability- Improve transmission and distribution network reliability - Enhance substation metering to reduce field service time - Maximize the use of existing infrastructure • Power quality- Verify compliance with new power quality standards- Analyze and isolate the source of power quality problems9410 Meter49410 | Selection and Application Guide9410 MeterCost-effective, modular designStandard features include a range of 3-phase power and energy measurements, total harmonic distortion (THD) metering, one RS-485 Modbus communication port,Dual- port Ethernet port, three digital inputs, one KY-type digital output, and alarming on critical conditions. The9410 meter has custom logging and power quality analysis capabilities, while expansion modules offer additional I/O.Easy installationMounts into panel cutouts using two clips with no tools required. Directly connects to circuits up to 600V AC, eliminating the need for voltage (potential) transformers.High-Visibility C O L O R displayIntegrated or remote LCD offers multi-phase measurements,summary screens, bar charts, intuitive navigation and selectable languages.High accuracy measurementsIEC 62053-22 class 0.2S and ANSI C12.20 0.2S real energy accuracy for sub-billing and cost allocation. For reactive energy Class 0.5S (IEC62053-24)Power quality analysisReveal and understand power quality conditions with the 9410 meter capabilities:• Dip and Swell detection• Waveform capture - 256 samples per cycle (Pre and Post)• Disturbance direction and detection • Trending and forecasting • Compliant PQ standards - IEC6100-4-30 Class S - IEC 62586- EN50160Extensive data logging, trending and forecastingNon-volatile on-board logging of min/max values, energy and demand, maintenance data, alarms, and any measured parameters. Trending and short-term forecasting of energy and demand.Custom alarming with time stampingTriggers alarms on over 50 definable power or I/O conditions. Use boolean logic to combine up to four alarms.Expandable I/OA wide choice of standard or optional digital and analog inputs and outputs for pulse counting, demand metering for other utilities (pulse inputs from water, air, gas electricity or steam meters), equipment status/position monitoring, demand synchronization, triggering conditional energy metering, equipment control or interfacing.Serial and Ethernet CommunicationsUp to two simultaneous Modbus communications ports. Use the RS-485 port on the base meter unit or the Dual-Port Ethernet for daisy-chaining via Ethernet. The Ethernet port will allow up to 8 supervisory systems to link to the meter at the same time and provide email-alarms and Modbus master functionality.Panel-mount meter with integrated display DIN-rail mounted meter with remote display option, including adapter, cable and displayFeatures and benefitsSelection and Application Guide |9410 MeasurementsPQ compliance reporting and basic PQ analysis •Monitors and logs parameters in support of international PQ standards,•IEC 61000-4-30 Class S•IEC 62586 PQI-S•EN 50160•Generates onboard PQ compliance reports accessible via onboard web pages:- Basic event summary and pass/fail reports, such as EN50160 for power frequency, supply voltage magnitude, supply voltage dips, short and long interruptions,temporary over voltages, voltage unbalance andharmonic voltage.- ITIC (CBEMA) and SEMI curves, with alarm categorization to support further analyses.- NEMA Motor Derating curve.- Basic meter provides EN 50160 but can be configured to provide IEEE 519.- Harmonic analysis:THD on voltage and current, per phase, min/max,custom alarming.- Individual harmonic magnitudes and angles on voltage and current, up to the 63rd harmonic.•Built-In web-enabled waveform viewer •High resolution waveform capture: triggered manually or by alarm, captured waveforms available directly from the meter via FTP in a COMTRADE format.•Disturbance detection and capture: sag/swell on any current and voltage channel, alarm on disturbance event, waveform capture with per-event information.•Patented disturbance direction detection: provides indication of the captured disturbance occurring upstream or downstream of the meter; time stamped results provided in the event log, with degree of certainty of disturbance direction.Used with , provides detailed PQ reporting across entire network:•EN 50160 report.•IEC 61000-4-30 report.•PQ compliance summary.•ISO 50001.•Display of waveforms and PQ data from allconnected meters.•Onboard data and event logging.•512MB of standard non-volatile memory.350 MB of standard non-volatile memory dedicated to capture billing data, events, and waveforms.Built-in web-enabled basic configurations, real-time data display,power quality harmonics display, phasor diagram display, andNew! power quality waveform viewer.569410 | Selection and Application Guide9410 MeterFront panel display showing function selection buttons and 3-phase voltage, current and power summary displayFront panel displayThe unique, anti-glare backlit white LCD can be easily read in extreme lighting conditions or viewing angles. An intuitive navigation with self-guided menus make the meter easy to use. Multilingual operation can be user-configured for English, Spanish, French, Italian, German, Portuguese, Chinese, and Russian.The large 6-line display offers summary screens thatsimultaneously presents up to 4 concurrent values, including power and energy values, I/O conditions or alarm status. Forexample, all three voltage or current phases plus neutral can be quickly reviewed at one time. Bar chart displays graphically represent system loading and I/O conditions. Historical and active alarms are displayed with time stamping. Active alarms can be Color coded for quick indication of alarm severity.The 9410 displays can also be customized to show anymetering point or imported data point from Modbus RTU/TCP connected devices, making this a unique central display for critical information.7Selection and Application Guide | 9410InstallationInstallation – Mounting optionsA meter with integrated display, or a remote display module, can be panel mounted through a square cutout ( 92 x 92 mm) or remote display retrofitted through an existinground meter hole using an adapter. A small panel footprint and shallow depth make the meters suitable for lowvoltage switchboards, shallow cable compartments or on standalone machines. The meter unit (without display) is DIN rail compatible.Meters with the optional integrated display can be door panel mounted when voltage connections are within thelocal regulation limits. When voltage exceeds regulation limits, the meter unit can be mounted inside the electrical cabinet with an optional remote display connecting via a display adapter and cable. A single remote display can be transferred between any meter units.Circuit and control power connectionsCompatible with low and high voltage 4-wire wye and 3-wire delta systems. Direct connect inputs up to 690 V AC line-to-line or use voltage (potential) transformers for higher voltage systems. All models offer a universal AC or DC power supply.3.78 in.96 mm3.78 in.96 mmDimensions for I/O Up to four modules 3.562 in.90.5 mm3.562 in.90.5 mm0.866 in.22 mm 77.5 in.3.051mm90.5 mm3.562 in.90.5 mm3.562 in.90.5 mm0.866 in.66 mm Dimensions for I/O modules typical. Up to four modules allowed to be connected.3.562 in.90.5 mm3.574 in.90.8 mm3.562 in.90.5 mm3.78 in.96 mm3.78 in.96 mmD.Dimensions:A. Meter with integrated display panel mount9410 |Selection and Application Guide9410 MeterFunctionsAlarm and control functions Array Over 50 definable alarm conditions with 1 second response time can be used to log critical events or to perform control functions. Trigger on over or under conditions on any measured parameters, phase unbalance, digital input changes and more.Multiple alarms can be defined, with each alarm individually configured with pickup setpoint, dropout setpoint and delay. Each alarm can be assigned one of four priority classes. Assign multiple alarms to a single quantity to create alarm levels. Assign different actions based on the severity levelof the alarm. Use alarms to trigger waveform recording, data logging or to control digital outputs.Customizable Programmable logic with the 9410 meter increases flexibility by allowing the combination of up to four other alarms using NAND, AND, OR, NOR and XOR functions. CommunicationsMultiple simultaneously operating communication ports allow the meters to be used as part of a power and energy management system and interface with other automation systems. Captured waveforms, alarms, billing data, and more can be uploaded to 6.0 or later for viewing and analysis. Option modules offer a choice of communications standards.• Standard RS-485 port (on meter unit): 2-wire connection, upto 38.4 kbaud, Modbus (ASCII and RTU) or JBUS protocol.• Support of IPv6• Dynamic Host Configuration Protocol (DHCP) IPv4 & IPv6 - DHCP is a network protocol that enables a server to automatically provide an IP address and other related information for a device. • A dual port 10/100 Base-T UTP port supporting ModbusTCP/IP, DNP3 and IEC 61850 communications. Full-function embedded web server provides standard web browser access to meter data, and the ability to email on an alarm from the host meter. RS-485/232 port, 2- or 4-wire, Modbus (ASCII and RTU) master port providing Ethernet-to-serial line gateway or Modbus master functionality.Software integrationIntegration with the system software allows for automatic retrieval of the meters real-time and on-board data logs. Modbus compatibility and register-based logged data supports integration and data access by building automation, SCADA and other third-party systems.Special featuresHour counter: load running time in days, hours and minutes.Upgradeable Firmware – Your meters can be upgraded withthe latest firmware. Contact your local Siemens representativefor details.8Selection and Application Guide |9410Harmonics web pageRealtime web pagePhasor web page Power Quality web page9410 Built-In Web PagesExample screen from software showing electrical system diagramwith multiple real-time metering points.Built-In web-enabled Waveform viewerThe 9410 comes with many standard HTML web pagesshowing the meters data, but additional custom web pagescan be designed to display other Modbus serial or ModbusTCP connected devices like power meters, trip units, flowmeter information, and more!99410 |Selection and Application Guide9410 MeterApplications and benefits•Maximize profits by providing high output with the least amount of risk to availability.•Improve availability and reliability of electrical systems and equipment.•Monitor power quality (PQ) for compliance and to prevent problems.•Meters fully supported by Power Monitoring Software.Main characteristics•Precision metering:•IEC 61557-12 PMD Sx K70 3000m 0.2 (performance measuring and monitoring functions).•Class 0.2S accuracy IEC 62053-22, ANSI C12.20 Class 0.2 (active energy).•Industry leading Class 0.5S* accuracy for reactive energy (IEC 62053-24).•Cycle-by-cycle RMS measurements updated every ½ cycle.•Full ‘multi-utility’ WAGES metering support.•Net metering.•Anti-tamper protection seals.•PQ compliance reporting and basic PQ analysis.•Monitors and logs parameters in support of international PQ standards- IEC 61000-4-30 Class S-IEC 62586 PQI-SDigital and analog inputs and outputsThe 9410 meter provides a three digital status/counter input and digital (KY type) output. A wide range of optional field-installable expansion modules will add more digital and analog I/O as required. Up to four expansion modules can be installed per meter (including loggingor communication modules).Digital output relays can act in response to internal alarms, external digital input status changes, or commands over communications. Digital inputs can be used to trigger alarms, trigger logging, and synchronize to a demand pulse or control conditional energy accumulation. Both models offer five channels for metering of water, air, gas, electricity or steam utilities through the digital input pulse counting and consumption/ demand calculation capabilities of the meter. Pulses from multiple inputs can be summed through a single channel communications. Up to 27 total digital inputs can be logged in the 9410 with millisecond time stamping for critical information like detailed sequence ofevent recording.Attachment of logging, I/O, or Ethernet expansion modules to meter unitBottom view of 9410 meter unit, showing dual Ethernet port and RS-485communication port connectors, configuration switches and 4x expansionI/O modules.1011Selection and Application Guide | 9410Ordering informationPlease contact your local sales representative for ordering information.Visit /pds for more information onother PDS products, applications and system solutions.The contents of this 9410 Selection and Application GuideManual shall not become part of or modify any prior orexisting agreement, commitment, or relationship. Thesales contract contains the entire obligation of Siemensrespecting the products. The warranty contained in thecontract between the parties is the sole warranty ofSiemens. Any statements contained herein do not createnew warranties or modify the existing warranty.Published bySiemens Industry, Inc. 2018.Siemens Industry, Inc.5400 Triangle ParkwayNorcross, GA 30092For more information, please contactour Customer Support Center.Phone: 1-800-241-4453E-mail: *******************/PDSOrder No.: PBBR-941SA-0118Printed in U.S.A.© 2018 Siemens Industry, Inc.The technical data presented in this document is based on an actual case or on as-designed parameters, and therefore should not be relied upon for any specific application and does not constitute a performance guarantee for any projects. Actual results are dependent on variable conditions. Accordingly, Siemens does not make representations, warranties, or assurances asto the accuracy, currency or completeness of the content contained herein. If requested, we will provide specific technical data or specifications with respect to any customer‘s particular applications. Our company is constantly involved in engineering and development. For that reason, we reserve the right to modify, at any time, the technology and product specifications contained herein.。

如何正确选择高压低压配电柜的电力仪表

如何正确选择高压低压配电柜的电力仪表

如何正确选择高压低压配电柜的电力仪表随着电力系统的不断发展和电气设备的不断更新,高压低压配电柜的电力仪表也成为了保障电力系统正常运行的关键设备。

正确选择电力仪表对于电力系统的稳定运行至关重要。

本文将介绍如何正确选择高压低压配电柜的电力仪表。

一、了解电力仪表的种类在选择电力仪表之前,我们需要先了解电力仪表的种类。

主要有电能表、电压表、电流表、功率因数表、频率表等。

不同的电力仪表具有不同的功能,通过对电力系统进行监测和测量,确保电力系统的正常运行。

二、确定所需的仪表功能选择电力仪表之前,我们需要明确所需的仪表功能。

根据电力系统的需要,确定是否需要测量电能、电压、电流、功率因数或频率等参数。

在安装电力仪表时,确保仪表的功能和所需参数与电力系统的要求一致。

三、考虑电力仪表的精确度和准确性精确度和准确性是选择电力仪表时需要考虑的重要因素。

根据电力系统的要求,选择具有高精确度和准确性的电力仪表,以保证测量结果的可靠性。

此外,还需要考虑电力仪表的刻度范围和显示方式,以适应不同的测量需求。

四、了解电力仪表的品牌和质量在选择电力仪表时,了解电力仪表的品牌和质量也非常重要。

优质的品牌往往具有较高的可靠性和稳定性,能够更好地适应电力系统的运行环境。

选择有信誉和口碑的品牌,可以提高电力仪表的使用寿命和工作效率。

五、考虑电力仪表的安装和维护便捷性除了仪表本身的功能和质量外,我们还需要考虑电力仪表的安装和维护便捷性。

选择安装和维护便捷的电力仪表,可以减少人力和时间成本,提高工作效率。

合理的安装和维护方式能够延长电力仪表的使用寿命,降低故障率。

六、参考其他电力系统的成功案例在选择高压低压配电柜的电力仪表时,可以参考其他电力系统的成功案例。

了解其他电力系统在选择电力仪表方面的经验和教训,可以帮助我们更好地做出决策。

通过借鉴成功案例,我们可以在选择电力仪表时避免一些常见的错误。

七、咨询专业的电力系统工程师如果对于电力仪表的选择仍然存在疑问,我们可以咨询专业的电力系统工程师。

电表和互感器的选择与型

电表和互感器的选择与型

电表与互感器的选择与型号一、电能表的定义电度表是用来自动记录用户电量的仪表,用以计算电费。

所谓一度电(即),表示功率为1000W的用电器用电1小时所耗用的电能。

电度表有单相、三相之分。

三相三线制用于动力,三相四线制用于照明或含三相用电设备的动力线路的计费。

选用时应根据电源及负荷情况选择。

?1、单相直接接入电度表额定电流:(6)A 1(2)A 2(4)A (5)A (10)A 5(10)A 5(20)A 5(30)A 10(40)A 10(60)A 15(60)A 20(80)A 极限 20(100)A(极少用到)等,最大可达100A,括号前的为基本电流值,也称叫标定电流,是作为计算负载基数电流值的,括号内的电流叫额定最大电流,是能使电能表长期正常工作,而误差与温升完全满足规定要求的最大电流值。

通过电能表的电流可高达基本电流的2~8倍,达不到2倍表上只标基本电流值。

也就是说,如果某用户所装电能表只标有一个电流值,如5A,这只是基本电流值,并非允许通过的最大电流。

对于这种电能表一般可以超载到120%也不会发生问题,而且能满足电能表的准确测量。

另一方面,感应系电能表由于其转动机构阻力较大,按标准规定起动电流不能低于基本电流的0.5%(准确度为级的电能表),可见电能表轻载到基本电流的0.5%以下时可能无法起动。

如果负载经常在100A左右的话建议选装三相四线电能表相对安全. 20(100)A的电能表在单相电能表电流规格中已属极限. 如果最大负载电流超过80A 可以适当选择此规格。

一般单项电度表允许短时间通过的最大额定电流为额定电流的2倍,少数厂家的电度表为额定电流的3倍和4倍。

?2、三相四线电度表额定电流:5(30)A 10(60)A 20(80)A 30(100)A等。

长时间允许通过的最大额定电流一般可为额定电流的倍,常用有(6)A 此规格均使用互感器接入。

常用表法如下:电压标法: 3X220/380 三相四线标法3X380 三相三线标法规程规定“经电流互感器接入的电能表,其标定电流宜不超过电流互感器额定二次电流的30%,其额定最大电流应为电流互感器额定二次电流的120%左右”电流互感器二次电流已标准化为5A,那么它的30%就是 A,其额定最大电流值就是6A。

高压低压配电柜的电能监测与计量技术

高压低压配电柜的电能监测与计量技术

高压低压配电柜的电能监测与计量技术在现代工业生产和日常生活中,电能的使用变得越来越重要和普遍。

而在电能使用的过程中,对于电能的监测与计量变得尤为重要。

特别是在高压低压配电柜中,电能的监测与计量技术的应用不仅可以提高电能的使用效率,还可以确保用电安全以及合理分配用电资源。

本文将介绍一些常见的高压低压配电柜的电能监测与计量技术。

一、高压低压配电柜的概述高压低压配电柜是用于控制和分配电能的装置。

它由高压部分和低压部分组成,高压部分主要负责接受来自变电站的高压电能,并将其分配给低压部分。

低压部分则将电能进一步分配给各个用电设备。

因此,高压低压配电柜的电能监测与计量技术对于电能的合理使用和管理具有重要作用。

二、高压低压配电柜的电能监测技术1. 电能量的监测电能量的监测是指对电能的使用情况进行实时监测和记录。

通过安装电能表和监测设备,可以准确地获取电能的使用量。

这不仅对于企业合理安排生产计划和节约能源有帮助,也对电网的负荷平衡和用电安全有重要意义。

2. 功率因数的监测功率因数是指电力系统中有功功率和视在功率之间的比值。

功率因数的监测可以帮助我们了解电能使用的效率,如何合理调整电能的使用方式。

通过对功率因数进行实时监测,可以发现用电设备存在的潜在问题,提高用电设备的效率,降低能源的消耗。

3. 电流、电压的监测在高压低压配电柜中,对电流和电压进行监测是非常重要的。

通过实时监测电流和电压的大小和波动情况,可以及时发现电力系统中的故障或异常情况,并采取相应的措施进行修复和防范,以确保用电设备的正常运行和人身安全。

三、高压低压配电柜的电能计量技术1. 电能表的选择和安装在高压低压配电柜中,电能表的选择和安装是电能计量的核心环节。

电能表应根据实际需要选择合适的类型和规格,确保其计量精度和稳定性。

同时,在安装电能表时,应遵循相关的标准和规范,保证其安全可靠地运行。

2. 能源管理系统的应用能源管理系统是一种集电能计量、数据采集、数据监测和数据分析为一体的综合管理系统。

浅谈单相电子式电能表的检验及选择

浅谈单相电子式电能表的检验及选择

区电网电压波动 比较 大。要注 意检查 电压波动极限情况下, 电能表
关键词: 电能表
0 引 言
检验
电子 式 电能 表 与 我 们 熟 悉 的感 应 式 电 能 表 《 称 机 械 表 )既 有 俗 , 电源的波纹不能有明显地增加。准确度要求还包括 , 如谐波、 外部磁 相同的地 方, 也有不相 同的地方 , 不同的地 方更 多, 且 特别是表的内 感应、 高频 电磁场影响等。一般地市级及县级供 电企业不具 备条件 部 , 应 式 电能 表 是 采 用 电磁 感 应 元 件 , 面 是 铁 芯 、 圈 加机 械传 感 里 铁 检 验, 可以请省级 电力试验所检验。 动 装 置 ; 电 子 式 电能 表 则 主 要 是 采 用 电 子 元 件 , : 而 即 电阻 、 电容 加 23电气要求 电气要求的功率消耗检验 , . 包括 电压线路和 电流 集成 电路等。 因此 , 应根据 电子式 电能表 的这一特性来进行选择。 换 线路 , 以用互感器校验 仪测量 电能表 的电压、 可 电流和 负载阻抗后 , 句话说要以 电子设备 的技术要求进行选择 , 而不能简 单的照搬 以前 计 算出额定 电压 、 额定 电流 下电能表 的功率消耗。这种方法既准确 选用机械式 电能表 的技术要 求选 择 电子式 电能表( 当然 , 也有可 以 又 方便 : 电源影响、 电压降落和短时中断、 自热影响可以在 电能表校 借鉴 的地方) 。现就我们在工作中体会 , 谈谈单相 电子式 电能表 的选 验 台上 模拟进行 ; 时过 电流会影响检验 , 短 严格按 规程定义做 比较 购, 供有 关的工作人员参考。 困难 , 可以在 2倍最大 电流下 , 逐步延长时间 , 检测 电能表 的温升 ( 电 1 查验 生产 厂 家 所 必 须 具 备 的基 本 技 术 条 件 流 端 子 及 取样 电 阻)和 误 差 。 这可 以 了解 电能表 过 负 载后 的损 坏 程 电能表是属 国家强制检验计量 器具 , 根据计量 法规定 , 所选 电 度 。为防止低压供 电线路中性点断开后 , 因负载不平衡 引起某相 电 能 表必须 具有 省级 以上技 术监 督局 颁发 的制 造计量 器具 许 可证 压 升高烧 坏 电能表 的情 况发生 ,将 单相 电表 的输入 电压 升高 到 ( MC证) 这是电能表生产厂家所必须具 备的条件和必须履行 的法 C 。 4 0 经过 4小时后 , 2 V, 再在额定 电压 下检验 电能表应合格( 试验时要 律手续。 它可以证 明厂 家具备 了基本 的设施、 人员和检测仪器设备 , 有人值守 , 注意安全 , 发现有异常立即断 电检查) 。 是可以生产销售 的产品。但是在 目前市 场竞争激 烈的情 况下, 电 供 24气候条件和 电磁兼容性 能 这两项对 电子式 电能来说都 很 . 企业有更大 的选择余地 , 因此 , 还可 以多比较 一下其他证 明产 品质 重 要 。 尤 其 是 电磁 兼 容 性 能 对 电 子 式 电 能表 影 响极 为 严 重 , 电磁 兼 量 的文件。如 : 权威部 门的鉴定报告 、 寿命试验 报告 、 被列入国家经 容性能较差的表 , 现场运行中往往 出现“ 死机 ” “ 、 飞字 ” 等现象, 甚至 贸委 ” 国城 乡 电网建设 与改造所需设 备产品及生产 企业推荐 目 全 内部 电子元件损坏。这是电子式电能表有别于机械式 电能表的一个 录 ”I0 0 0质量认证等等。这些都 是证 明产 品质量 的重要文件 。 重要特性。电磁兼容检验一共有 5个项 目, : 电放 电试验 、 、 90 S 即 静 高频 由于各厂家价格竞争激烈 ,根据经验仅仅凭 这些文件还是 不够 的, 电磁场试验、 电快速瞬变脉冲群试验 、 浪涌试验 、 无线 电干扰抑制试 只能证 明有 了可以选 用的基础。下一步就要根据 电子式 电能表的性 验。其中浪涌和脉 冲群 比较接近 电网中的一些瞬态情况 , 建议有条 能特点、 国家检验 规程 , 合当地 电网和气候 的实际情况对厂 家生 件 的地市级及县级供 电企业购置相应 设备 ,对 电能表进行抽查 检 给 产的电能表实物进行检验 。 验。另外需要注意的有 , 由于 目前电子表 的机械计量器 , 还没有从原 2 对 电 能表 实物 进 行 检 验 理 上 根 本解 决 卡 字 问题 。主要 是 通 过选 择 制造 工 艺 好 的计 量 器 和 进 对 厂家送 来的 电能表 实物 进行 检验 , 要是从 以下 几 个方面 进 行。 主 厂时严格筛选 保证 电能表整机质量。 因此 , 要特 别注意计量器的质 即: 机械要求、 所能适应 的气候条件、 电气要求、 电磁兼容性、 准确度要 量 。步进 电机 有 屏 蔽 可 以 防 电磁 干 扰 , 壳 采 用 铝合 金 支 架 、 轮 精 外 齿 求这五个方面。这五个方面在国家标准《 1级和 2 级静止式交流有功电 细、 无毛刺、 材料不 易变形 、 自润 滑性 能、 有 步进 电机磁性 能强 、 加工 能表》 /1 2 - 9 8中都有明确的规定。规定中有些试验和检验 精密 , ( T 1 1 9 ) GB 7 5 都可以减 少卡字的问题。 要注意仔细检查和 了解。 再就是要进 项 目一般地市级及县级供电企业有条件检验,但有相当多的项 目还不 行走字检 验。为更严格地考核计量器质量 , 保证 安装到现场的 电能 具备条件检验。下面将需要注意的地方和解决的办法做一简要说明。 表 在 电压 允许 范 围 内都 能 正 确 计 量 , 议 采 用 本 地 区 电网 可 能 出 现 建

安装三相四线电能表的注意事项

安装三相四线电能表的注意事项

安装三相四线电能表的注意事项安装三相四线电能表是一项非常重要的任务,它关系到电力供应的安全和稳定运行。

下面是安装三相四线电能表时需要注意的事项:一、前期准备工作1. 确定接入点:根据电力供应点和用电负荷的需要,确定三相四线电能表的接入点。

接入点应与电源线路的终点相对应,以确保电能计量的准确性和可靠性。

2. 选择合适的电能表:根据用电负荷和电压等级选择适合的三相四线电能表。

电能表的额定电流和额定电压应与被测电路的参数相匹配。

3. 安装位置选择:选择一个干燥、通风良好、温度适宜的位置安装电能表。

避免与其他电气设备或水源等有潜在危险的设备靠近,以确保安全性。

二、安装电能表1. 检查和清理电气设备:在安装电能表之前,先检查用电负荷设备和线路的电气连接是否正常。

同时,清理杂物和灰尘以确保电能表的准确度。

2. 连接电源线路:根据电能表的连接图,正确连接电源线路。

确保三相线和零线正确连接,避免导致线路短路或断路的情况发生。

3. 固定电能表:使用合适的工具将电能表固定在安装位置上,确保电能表的稳定性。

注意不要损坏电能表的外壳和内部元件。

三、接线连接1. 线序检查:在接线之前,检查线序是否正确。

确保A、B、C三相线与电源主线的相位对应关系正确。

2. 接线规范:按照电能表的接线图,将电源线路和用电负荷线路正确接入电能表的对应接线端子上。

注意保持接线端子的干净和紧固状态,以确保电能表的正常运行。

3. 地线连接:将电能表的地线正确接入到接地线中,以确保安全。

四、终端测试1. 供电测试:在接线完成后,进行供电测试。

检查电能表是否能够正确读取电能数据,尤其是有无误差和异常。

2. 动态测试:通过合理的负荷运行,验证电能表的稳定性和可靠性。

记录测试结果,以备后续参考和分析。

3. 警示标识:安装完成后,在电能表周围设置相应的警示标识,以提醒人员注意电流和电压的存在,防止误操作和事故发生。

五、验收和维护1. 验收检查:完成安装后,进行验收检查,确保安装质量和电能表的正常运行。

电能表校准方案(二)

电能表校准方案(二)

电能表校准方案(二)电能表校准方案一、背景介绍电能表是用于测量电能的仪器,其准确性对保障能源计量的公正性和可靠性至关重要。

为确保电能表的准确性,需要定期进行校准。

二、校准目的通过校准电能表,确保其测量结果的准确性,提高能源计量的公正性和可靠性。

三、校准内容1.电能表表盘读数校准–通过标准电能表与被校准电能表逐相比较,记录差值;–根据记录的差值,调整被校准电能表的表盘读数,确保准确性。

2.电能表误差校准–通过标准电能表与被校准电能表逐相比较,记录差值;–根据记录的差值,计算被校准电能表的误差,并进行调整,使误差控制在合理范围内。

四、校准方法1.标准电能表选择–选择具有较高准确度的标准电能表作为参照;–标准电能表应定期送检,并确保其准确度。

2.校准仪器准备–准备标准电能表和被校准电能表;–确保校准仪器完好,无故障。

3.校准过程–将标准电能表与被校准电能表逐相比较,记录差值;–根据记录的差值,分别调整被校准电能表的表盘读数和误差。

4.校准结果记录–记录标准电能表与被校准电能表之间的差值;–记录被校准电能表的表盘读数和误差调整情况。

五、校准周期根据实际情况和法规要求,确定电能表的校准周期,并确保按时进行校准工作。

六、校准责任人及其任务1.校准责任人:–负责制定校准计划和安排校准工作;–监督校准过程,确保准确性。

2.校准任务:–负责准备校准仪器;–执行校准过程,记录校准结果;–编制校准报告。

七、校准记录保存与归档校准记录应进行保存和归档,以备查阅和审计。

八、校准评估与改进定期对校准过程和校准结果进行评估,发现问题及时改进,提高校准工作的质量和效率。

以上即为电能表校准方案的相关内容,通过定期校准,确保电能表的准确性,提高能源计量的可靠性和公正性。

电力设备的电能计量与校准方法

电力设备的电能计量与校准方法

电力设备的电能计量与校准方法在现代社会中,电力设备已经成为人类生活不可或缺的重要组成部分。

为了准确计量和校准电力设备的电能,确保电能计量的准确性和公正性,我们需要采取一系列科学的方法。

本文将介绍电力设备的电能计量与校准方法。

一、电力设备的电能计量方法1. 电能表计量法电能表是常用的电能计量设备,它通过测量电压、电流和功率因数来实现对电能的计量。

在使用电能表进行电能计量时,应注意以下几点:(1)选择合适的电能表:根据电流大小、工作环境和其他特殊要求,选择合适的电能表进行计量。

(2)确保电路连接正确:电流线路和电压线路的连接应准确无误,确保电能表正常工作。

(3)定期检查电能表的运行状况:定期检查电能表的表盘、指针和数字显示是否正常,如发现异常应及时更换或修理。

2. 分散计量法分散计量法是指将不同电能使用者的电能表分开安装在各自的用电端口,分别计量各自的用电量。

这种计量方法适用于多电能使用者的情况,可以更准确地计量每个使用者的电能。

3. 远程计量法远程计量法采用先进的通信技术,将电能表与计量中心相连,实现对电能的远程计量。

这种计量方法可以方便地获取各个使用者的电能信息,并进行统一管理。

二、电力设备的电能校准方法1. 校准准备工作在进行电能校准之前,需要进行一些准备工作,包括:(1)校准环境准备:确保校准环境符合规定的要求,没有干扰源或杂散电磁场。

(2)校准仪器准备:校准仪器应保持良好的状态,准确可靠。

2. 校准过程电能校准一般包括以下几个步骤:(1)连接校准仪器:将校准仪器与待校准设备连接,确保信号传输的准确性。

(2)比较校准:将校准仪器与已知精度的标准设备进行比较,通过比较得到校准结果。

(3)调整校准:根据比较结果,对待校准设备进行调整,使其达到预定的校准要求。

(4)校准记录:完成校准后,做好校准记录,包括校准日期、校准参数和校准结果等信息。

三、电力设备的电能计量与校准的意义准确的电能计量和校准对于电力行业的正常运行和社会公平公正具有重要意义。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

如我们常用的家用单相电度表:DD862-4型、DDS97l型、DDSY97l型等。

电流互感器和电能表的选用标准
电流互感器和电能表选用的级别,是由电能计量装置的类别决定的,
运行中的电能计量装置按其所计量电能量的多少和计量对象的重要程度分五类:Ⅰ类电能计量装置月平均用电量500万kWh及以上或变压器容量为10000kVA及以上的高压计费用户、
200MW及以上发电机、发电企业上网电量、电网经营企业之间的电量交换点、省级电网经营企业与其供电企业的供电关口计量点的电能计量装置。

Ⅱ类电能计量装置月平均用电量100万kWh及以上或变压器容量为2000kVA及以上的高压计费用户、100MW及以上发电机、供电企业之间的电量交换点的电能计量装置。

Ⅲ类电能计量装置月平均用电量10万kWh及以上或变压器容量为315kVA及以上的计费用户、100MW以下发电机、发电企业厂(站)用电量、供电企业内部用于承包考核的计量点、考核有功电量平衡的110kVA及以上的送电线路电能计量装置。

Ⅳ类电能计量装置负荷容量为315kVA以下的计费用户、发供电企业内部经济技术指标分析、
考核用的电能计量装置。

Ⅴ类电能计量装置单相供电的电力用户计费用电能计量装置。

Ⅰ类电能计量装置应至少配0.2s或0.5s等级的有功表,2.0等级的无功表,0.2等级的互感器。

Ⅱ类电能计量装置应至少配0.5s或0.5等级的有功表,2.0等级的无功表,0.2等级的互感器。

Ⅲ类电能计量装置应至少配1.0等级的有功表,2.0等级的无功表,0.5等级的互感器。

电能表铭牌电流5(10)A、10(20)A、5(20)A有何区别?
常用电能表的规格有哪些?
三相:1.5(6)A 此规格均需要互感器接入;还有5(30)A ,10(60)A,20(80)A,30(100)A. 通俗点说就是负荷开关或者断路器脱扣器的整定电流要在其内,超过100A的加互感器用1.5(6)A.
欢迎您的下载,
资料仅供参考!
致力为企业和个人提供合同协议,策划案计划书,学习资料等等
打造全网一站式需求。

相关文档
最新文档