浅谈变电站一次设备的设计与选择

合集下载

毕业设计110kv变电站一次、二次系统设计

毕业设计110kv变电站一次、二次系统设计

毕业设计(论文)论文题目:110千伏终端变电站一次系统设计学生姓名:学号年级、专业、层次:二00六年三月目录第一章设计题目 (1)一.毕业设计课题 (1)二.毕业设计的内容要求 (1)第二章变压器容量确信 (2)一.主变容量的确信 (2)二.所用变压器容量的确信 (3)第三章电气主接线确信 (3)一.方案技术经济比较原那么 (4)第四章短路电流及要紧设备选择 (5)一.短路电流计算 (5)二.主设备选择 (8)三.主设备校验 (10)第五章绝缘配合及过电压爱惜 (16)一.绝缘配合 (16)二.过电压爱惜 (17)三.接地 (17)四.泄漏比距 (18)第六章电气设备布置及配电装置 (18)一.电气设备布置 (18)二.配电装置的型式 (19)第七章电容器补偿装置 (19)第八章爱惜配置及交直流部份 (19)一.110千伏线路爱惜配置 (19)二.变压器爱惜配置 (19)三.35千伏线路爱惜配置 (20)四.10千伏线路爱惜配置 (20)五.10千伏电容器组爱惜配置 (20)六.逻辑闭锁 (21)七.交流系统 (21)八.直流系统 (21)第九章监控系统功能配置 ..................................................... 错误!未定义书签。

一.系统结构 ..................................................................... 错误!未定义书签。

二.硬件设备配置............................................................ 错误!未定义书签。

三.软件系统 ..................................................................... 错误!未定义书签。

四.系统功能 ..................................................................... 错误!未定义书签。

66kV变电站一次部分设计

66kV变电站一次部分设计

60kV变电站一次部分设计摘要随着工业时代的不断发展,人们对电力供应的要求越来越高,特别是供电的稳固性、可靠性和持续性。

然而电网的稳固性、可靠性和持续性往往取决于变电站的设计和配置。

由于变电所的设计内容多、范围广、逻辑性强,因此要求要有较高的专业水平,并熟悉各种设计规程和设计原理,设计过程中要针对变电所的规模和形式,具体问题具体分析。

本文是60kv/10kv降压变电所的一次变电的设计方案。

本设计包括对导线的选择,主变压器的选择,无功补偿静电电容器的选择,电气主接线的确定,短路计算,各种电气设备的选择与校验,高压配电装置的规划设计。

在设计和选择设备中都充分考虑到了可靠性,灵活性和经济性。

另外,各种断路器、隔离开关、电流互感器型号的选择要与高压配电装置的布置联系在一起考虑。

本设计是有文字说明和图表解释的比较完整的变电所的设计方案。

关键词:电力系统;电气设备;变压器;变电站The design of 60kv satellite substationAbstractWith the development of the industrial time , people have higher demand of the power supply, especially the power supply stability, reliability and consistency. However, power grid stability, reliability and durative often depends on the design and configuration of substation. As a result of substation design, a wide range of content, logic is strong, it is required to have higher professional level, and are familiar with a variety of design procedures and design principle, design process for substation the size and form, concrete analysis of concrete problems. This is the 60kv/10kv substation of a substation designThis design including the selection of conductors, the selection of main transformer, reactive power compensation capacitors, the main electrical wiring, short-circuit calculation, all kinds of electrical equipment choice and verification, the planning and design of high voltage distribution device. In the design and selection of equipment are fully taken into account the reliability, flexibility and economy. In addition, a variety of circuit breaker, isolating switch, current transformer model should be selected with the high voltage distribution device arrangement linked to consider.This design is a written instructions and diagrams explain the relatively complete substation design.Keywords power system;electrical equipment,;transformer;Transformer substation目录摘要 (I)Abstract (II)第1章绪论 ............................................................................................................ . (1)1.1 课题背景 ............................................................................................................... .1 1.2 合理设计变电站的意义.................................................................................... .1 1.3 变电站设计相关的原则和规范.. (2)第2章10kv线路导线的选择..................................................................................... ..4 2.1选择机械制造厂出线架空型号 ....................................................................... .4 第3章选择主变压器的台数、容量、型号. (9)3.1 线路损耗的总功率 (9)3.2线路所有负荷的总功率 (9)3.3计算变压器二次侧总功 (10)3.4选择变压器型号 (11)第4章补偿电容器的选择 (13)4.1计算变压器功率损耗 (13)4.2计算变压器高压侧功率 (13)4.3计算无功补偿前系统的功率因数 (13)4.4计算需要补偿的无功容量 (13)4.5选择电容器 (14)第5章电气主接线方案设计 (16)5.1主机线设计的基本要求 (16)5.2主接线方案 (17)第6章短路电流的计算 (18)6.1发生短路的原因和短路的定义 (18)6.2短路的分类 (18)6.4短路电流的计算 (18)第7章电气设备的选择 (20)7.1断路器的选择 (20)7.2隔离开关的选择 (23)7.3互感器的选择 (24)7.4避雷器的选择 (27)7.5高压开关柜的选择 (28)7.6母线的选择 (28)结论 (33)致谢 (34)参考文献 (35)附录A (36)附录B (37)第1章绪论1.1课题背景电力工业是关系国计民生的基础产业,在我国电力工业发展中,国家电网承担着优化能源资源配置,保障国家能源安全和促进国民经济发展的重要作用。

35kV变电站电气一次部分初步设计分析

35kV变电站电气一次部分初步设计分析

35kV变电站电气一次部分初步设计分析35kV变电站是电力系统输配电的重要组成部分,其电气一次部分的设计是关键环节之一。

本文对35kV变电站电气一次部分的初步设计进行分析。

一、工程概况本工程位于某市,建设规模为35kV变电站,设计容量为10MVA。

主要负责接受输电系统的电能,对电能进行变压、配电和保护控制等处理,最终将电能供应给现场用电设备。

二、变电站布置变电站采用房间式室内变电站,建筑面积为500平方米。

变电站主体设备包括主变压器、高压开关柜、低压开关柜、电缆室等,站区内应设置合理的道路、绿化、防火设施等。

三、电力系统该变电站为10kV配电网的端点供电,同时接受35kV电网输电,并根据需要进行变压,主要用于城市配电。

输电线路采用双回45kV线路,总长17km,其中变电站至线路起点距离为2km。

主变压器一侧为35kV高压侧,另一侧为10kV低压侧。

1.高压开关柜高压开关柜是35kV变电站电气一次部分的核心装置之一,主要负责电网与变电站主体设备之间的连接,保障电力系统的可靠运行。

该变电站采用的是户外SF6高压断路器,其优点在于容易维护、结构紧凑、质量高等。

2.主变压器主变压器是35kV变电站的主要设备之一,负责变换电压和功率,使电能能够传输到10kV配电网,并保证电能供应的可靠性。

本工程选用10MVA三相油浸式变压器。

低压开关柜是35kV变电站电气一次部分的重要设备,主要用于控制和保护10kV配电系统。

本工程采用GN63A-12型低压开关柜,具有质量高、操作方便、安全可靠等优点。

4.电缆室电缆室是变电站的重要组成部分,负责将输电线路和主变压器等设备之间的电缆进行接入。

本工程电缆室采用的是户内配电室,主要装备有V型电缆支架、电缆编织管等设备。

5.控制保护系统控制保护系统是35kV变电站电气一次部分的重要组成部分,主要用于对电气设备进行保护控制。

本工程选用的保护设备包括电流互感器、电流表、电压互感器、电压表等。

变电站电气一次设计总结

变电站电气一次设计总结

变电站电气一次设计总结发布时间:2022-12-05T08:30:01.354Z 来源:《福光技术》2022年23期作者:赵华博王瑞芳[导读] 一次设备过热问题。

变电站连续运行时,部分一次设备会出现温度快速提升、过热等问题,可能会埋下隐患。

线路及相关设备长期处于过热条件下,会其使用寿命下降、故障几率增加。

呼和浩特供电公司内蒙古呼和浩特 010000摘要:近年来,国家电力部门依据当前科技发展的水平,对变电站供电的可靠性、电压合格率等指标提出了新的要求,进一步维护了我国电力系统的稳定性,以满足人民群众的需求。

根据当前人们对于优质、稳定、实惠的电能需求,国家相关的电力设计部门在一次设计过程中需结合人民群众对电力性能的要求,同时结合实际情况,从质量、安全、性能、价格等多重角度思考,构建出变电站电气一次设计框架,以科学、专业的电力知识和技能解决设计中存在的问题,不断地探索、总结经验,思考解决方法,从而保证电气一次设计的质量水平。

关键词:变电站;电气一次设计1变电站电气一次设计现状(1)一次设备过热问题。

变电站连续运行时,部分一次设备会出现温度快速提升、过热等问题,可能会埋下隐患。

线路及相关设备长期处于过热条件下,会其使用寿命下降、故障几率增加。

如果不及时针对相关故障进行处理,极易引发故障的扩大化。

工程经验表明,电气一次设备中,存在过热问题情况下,其故障多数与导体截面大小相关。

为此,设计中,需充分考虑小截面积条件下,高温工况设备的稳定性,避免设备过度发热等状况的发生,降低线路短路等情况的发生。

因此,变电维修处理中,相关人员要提高养护问题的关注度,结合部件特点、功能和类型等进行养护处理。

如刀闸,一般需长期使用,易发生腐蚀问题,为此,采用导线涂膜法进行防腐保护,力求借助保护膜来降低故障事故的发生。

(2)雷击问题。

结合变电站的电气系统分析,其所处环境相对复杂,易受外界天气条件影响,如雷电天气下,可能会增加电力系统的运行负荷。

变电站的主要一次设备

变电站的主要一次设备
汇报人:
,a click to unlimited possibilities
目录
变电站的定义和作用
添加标题
变电站的定义:变电站是电力系统中变换电压、接受和分配电能、控制电力的流向和调整电压的电力设施,它通过其变压器将各级电压的电网联系起来。
变电站的作用:变电站的主要作用是变换电压、接受和分配电能、控制电力的流向和调整电压,以确保电力系统的稳定运行和满足用户的需求。同时,变电站也是电力系统中重要的监控和保护设施,可以监测和控制电力系统的运行状态,及时发现和处理故障,保障电力系统的安全和稳定。
母线:用于汇集和分配电能,确保设备之间的连接和运行稳定。
电流互感器和电压互感器:用于将高电压或大电流转换为低电压或小电流,以便于测量和保护设备的正常运行。
变压器是一种利用电磁感应原理改变交流电压的设备变压器的主要功能是将一种电压的交流电能转换成另一种电压的交流电能变压器由铁芯(或磁芯)和线圈组成 变压器的种类变压器的种类电力变压器:用于电力系统中的升压和降压仪用变压器:用于测量仪器和保护装置中特种变压器:用于特定场合,如整流、矿用、试验等 变压器的结构变压器的结构铁芯:由硅钢片叠成,构成磁路线圈:绕在铁芯上,形成初级和次级线圈绝缘材料:保证线圈之间的绝缘 变压器的原理变压器的原理当一次线圈接上交流电源时,产生交变磁场交变磁场在二次线圈中产生感应电动势感应电动势的大小与线圈匝数成正比,从而实现了电压的变换
添加标题
变电站的主要设备
01
03
05
02
04
06
避雷器:用于保护设备免受雷电和操作过电压的损害。
断路器:用于切断或接通电流,确保设备在故障或维护时能够安全停运。
变压器:用于将高电压转换为低电压或将低电压转换为高电压,以满足不同电压等级的需求。

220kv变电站一次部分设计毕业论文

220kv变电站一次部分设计毕业论文

河南理工大学毕业设计(论文)说明书摘要随着经济的发展和现代工业建设的迅速崛起,供电系统的设计越来越全面、系统,工厂用电量迅速增长,对电能质量、技术经济状况、供电的可靠性指标也日益提高,因此对供电设计也有了更高、更完善的要求.本设计主要介绍了220kV变电站一次部分的设计。

首先通过对原始资料进行分析,设计主接线形式,综合比较各种接线方式的特点、优缺点,根据电气主接线设计的基本要求选择两种较其它方案可靠的主接线方案;再对两种方案进行全面的可靠性、灵活性和经济性比较,确定最优的主接线方案;然后根据题目要求选择主变压器的台数以及容量,再进行短路电流计算,为设计中需要的高压电气设备的选择、整定、校验等方面做准备;继而进行主要电气设备的选择与校验,最后进行防雷保护设计。

关键词:变电站;主变压器;短路计算;电气设备选择。

ABSTRACTWith the development of economy and the rapid rise of the modern industrial construction, design of power supply system is more and more comprehensive,system,factory power consumption increased rapidly,the power quality, technical and economic conditions, power supply reliability index is increasing, so the design of power supply also has a higher, better.This design mainly introduces the design of 220 kv substation a part。

Through analyze the raw data first, design main wiring forms, comprehensive comparison of various characteristics of wiring method,advantages and disadvantages,choose according to the basic requirement of the main electrical wiring design two kinds of main wiring scheme than other solutions and reliable;Again to the reliability of the two plans to conduct a comprehensive,flexible and economical comparison,to determine the optimal main wiring scheme; Then the sets and the capacity of main transformer according to the request of topic selection, short-circuit current calculation again, needed for the design of high voltage electrical equipment choice preparation, setting,calibration, etc;And then to the main electrical equipment selection and calibration, finally carries on the lightning protection design。

10kV变电站一次和二次设备的技术改造分析

10kV变电站一次和二次设备的技术改造分析

10kV变电站一次和二次设备的技术改造分析摘要:当前我国电网系统实现了全面覆盖,人们越发重视变电站设备运行安全质量,所以关于变电站的检修十分关键,尤其是二次设备的检修更成为影响电网稳定运行的关键。

10KV变电站一次和二次设备技术改造对增强电网稳定性有十分关键的作用,文章主要描述变电站一次与二次改造,讨论技术改造的实现。

关键词:10KV;一次设备;二次设备随着我国电力供应在国内的持续发展,电力成为人们生活内容的一部分电力作为国民经济的重要组成部分,在现实生活中需要保证自身的发电输电与配电的基本功能。

电力系统整体结构比较复杂,具体由发电厂、输电系统等组成。

变电站一次设计,需要充分考虑怎样保证系统运行的稳定与可靠。

变电所作为电力系统的一部分,在联机与配电系统中都十分关键。

1.10KV变电站一次与二次设备按照实际来看,电力设计基本原则是以任务书为根据,满足国家标准,电力工程的建设必须要保证供电的可靠与稳定,确保满足规范。

在变电站的建设中灵活稳定,满足各种技术规范。

变电站建设必须坚固稳定,同时尽可能就地取材,保证设备的先进与技术的可靠,坚持可持续利用原则。

工程建设的前期会根据任务书确定变电所的容量内容和电压等级,这些均是一次设计和二次设计的根据,必须进行详细的分析才可以顺利展开。

作为电气设计内容的主体部分,主接线部分十分重要,对设备的稳定与可靠的有很大影响。

因此在具体的建设中,需要合理选择主接线方案和主变压器。

变电站投入运行之后,会不断的进行改造,在设计上遵循国家以及行业部门的相关规范,系统性的展开综合自动化改造。

在新的信息技术的支持下,变电站投运期间的改造次数逐渐增多,电厂的科技含量也不断提升,电厂的生产运营中变电站改造设计应符合无人值班的要求,根据电力系统发展规划以及地方的电力负荷需求,进行针对性的改造。

2.项目以及改造范围本文讨论的10KV变电站投入运行之后,负责周围工农业的生产以及生活的用电。

在使用期间内曾经进行多次改造,现在改造已经初步实现综合自动化。

110KV 变电所一次设备部分设计

110KV 变电所一次设备部分设计

湖南铁路科技职业技术学院毕业设计(论文)任务书课题厦门海沧110KV牵引变电所的一次设备部分设计编号专业电气化铁道技术班级312-1学生姓名贺桂林指导单位湖南铁路科技职业技术学院指导教师陈衡峰摘要本设计参考类似工程而做,共分三个部分。

第一部分为设计任务书,主要介绍新建变电所的基本资料、110KV用户负荷统计资料、主电路的设计,待建变电所与电力系统的连接情况、设计任务及要求。

第二部分为变电所计算部分,包括负荷计算、无功补偿计算、主变容量选择计算、所用电容量选择计算、短路电流计算;以及新建变电所主方案的确定、主要设备选择过程及结果等。

第三部分包括图纸和参考文献。

本论文以厦门海沧110KV变电站资料为背景,从原始资料的分析做起,目的是通过变电站设计,综合运行所学知识,结合实际工作贯彻执行我国电力工业有关方针政策及技术标准,做到理论联系实际。

培养独立分析和解决实际工程技术问题的能力,同时也为今后工作打下良好的基础。

牵引变电所一次设备的设计是铁路供电设计的重要组成部分。

其内容包括主接线形式的选择,短路电流的计算,设备的选择与校验计算等多方面设计内容。

本文的主要设计内容包括:(1) 根据负荷情况确定变压器的容量。

(2) 根据实际工程要求与国家设计规范的要求选择主接线形式。

(3) 选择了系统中具有典型性的两个短路点,计算他们的短路电流。

(4) 根据所得到的短路电流计算结果选择、校验设备。

(5) 绘制变电所主接线图、平面俯视图、侧面剖视图。

关键词:牵引变电所;电气主接线;变压器容量目录绪论 (1)第一章待建变电所原始资料 (3)第二章牵引变电所概论 (5)2.1 牵引变电所设计概述 (5)2.2 牵引变电所的分类 (5)2.2.1 牵引变电所按牵引网电流性质的分类 (5)2.2.2 交流牵引变电所按频率和牵引网相数的分类 (5)2.2.3 工频单相交流牵引变电所按主变压器结构种类和接线方式的分类 (6)2.3 牵引变电所的设计原则 (6)2.4 牵引网与接触网 (7)第三章电气主接线方案的确定 (8)3.1 电气主接线概述 (8)3.2 电气主接线的基本形式 (8)3.2.1 单母线接线 (8)3.2.2 桥形接线 (9)3.3 牵引变电所主接线 (12)3.3.1 三相YN,D11接线变压器 (12)3.3.2 单相V,v接线变压器 (12)3.3.3斯科特接线变压器 (13)3.4牵引侧主接线 (13)3.4.1 27.5kV(或55kV)侧馈线的接线方式 (13)3.4.2 复线铁路斯科特接线变压器AT供电方式馈电线接线 (15)3.4.3 动力变压器及自用电变压器接线 (16)3.5 主接线方案 (17)3.5.1 主接线方案的拟定 (17)3.5.2 主接线方案的确定 (17)第四章高压电器设备的选择 (19)4.1 电器选择的一般原则 (19)4.1.1 按正常工作条件选择高压电器设备 (19)4.1.2 按短路时故障情况进行效验 (19)4.2 高压断路器的选择 (19)4.2.1 110kV侧断路器的选择 (19)4.2.2 10 kV侧断路器的选择 (20)4.3 隔离开关的选择 (20)4.4 电压母线的选择 (21)4.5 各主要电气设备选择结果一览表 (22)第五章变压器容量的确定 (23)5.1 牵引变电所容量和负荷计算 (23)5.2计算条件 (23)4.3牵引变压器的计算容量 (25)结论 (28)致谢 (29)参考文献 (30)附录 (31)绪论电力工业是国民经济的一个重要组成部分,它为工业、农业、交通运输和城市提供能源。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

浅谈变电站一次设备的设计与选择
摘要:由于电气设备和载流导体得用途及工作条件各异,因此它们的选择校验项
目和方法也都完全不相同。

本文针对110kV变电站电气一次设计中的部分技术问题。

包括变电站主接线、电气平面布置和主变压器的选择提出了一些技术设想,可
为其他工程设计提供借鉴和参考。

关键词:变电站;一次设备;设计
由于电气设备和载流导体得用途及工作条件各异,因此它们的选择校验项目和
方法也都完全不相同。

但是,电气设备和载留导体在正常运行和短路时都必须可
靠地工作,为此,它们的选择都有一个共同的原则。

一、电气设备选择的一般原则
1.应满足正常运行检修短路和过电压情况下的要求并考虑远景发展。

2.应满足安装地点和当地环境条件校核。

3.应力求技术先进和经济合理。

4.同类设备应尽量减少品种。

5.与整个工程的建设标准协调一致。

6.选用的新产品均应具有可靠的试验数据并经正式签订合格的特殊情况。


择的高压电器,应能在长期工作条件下和发生过电压、过电流的情况下保持正常
运行。

7.绝缘水平:在工作电压的作用下,电器的内外绝缘应保证必要的可靠性。

接口的绝缘水平应按电网中出现的各种过电压和保护设备相应的保护水平来确定。

由于变压器短时过载能力很大,双回路出线的工作电流变化幅度也较大,故其计
算工作电流应根据实际需要确定。

高压电器没有明确的过载能力,所以在选择其
额定电流时,应满足各种可能方式下回路持续工作电流的要求。

二、一次设备的设计与选择
(一)高压断路器的选择
高压断路器在高压回路中起着控制和保护的作用,是高压电路中最重要的电
器设备。

型式选择:本次在选择断路器,考虑了产品的系列化,既尽可能采用同
一型号断路器,以便减少备用件的种类,方便设备的运行和检修。

选择断路器时应满足以下基本要求:
1.在合闸运行时应为良导体,不但能长期通过负荷电流,即使通过短路电流,也应该具有足够的热稳定性和动稳定性。

2.在跳闸状态下应具有良好的绝缘性。

3.应有足够的断路能力和尽可能短的分段时间。

3.应有尽可能长的机械寿命和电气寿命,并要求结构简单、体积小、重量轻、安装维护方便。

(二)隔离开关的选择
隔离开关是高压开关设备的一种,它主要是用来隔离电源,进行倒闸操作的,还可以拉、合小电流电路。

选择隔离开关时应满足以下基本要求:
1.隔离开关分开后应具有明显的断开点,易于鉴别设备是否与电网隔开。

2.隔离开关断开点之间应有足够的绝缘距离,以保证过电压及相间闪络的情
况下,不致引起击穿而危及工作人员的安全。

3.隔离开关应具有足够的热稳定性、动稳定性、机械强度和绝缘强度。

4.隔离开关在跳、合闸时的同期性要好,要有最佳的跳、合闸速度,以尽可
能降低操作时的过电压。

5.隔离开关的结构简单,动作要可靠。

6.带有接地刀闸的隔离开关,必须装设连锁机构,以保证隔离开关的正确操作。

(三)各级电压母线的选择
选择配电装置中各级电压母线,主要应考虑如下内容:
1、选择母线的材料,结构和排列方式;
2、选择母线截面的大小;
3、检验母线短路时的热稳定和动稳定;
4、对35kV以上母线,应检验它在当地睛天气象条件下是否发生电晕;
5、对于重要母线和大电流母线,由于电力网母线振动,为避免共振,应校验母线自振频率。

根据设计要求, 35KV母线应选硬导体为宜。

LGJ—185型钢芯铝绞线即满足
热稳定要求,同时也大于可不校验电晕的最小导体LGJ—70,故不进行电晕校验。

(四)绝缘子和穿墙套管的选择
定和绝缘,是由导电体、绝缘子和金具来实现的。

所以,绝缘子必须有足够
的绝缘强度和机械强度,耐热、耐潮湿。

选择户外式绝缘子可以增长沿面在发电
厂变电站的各级电压配电装置中,高压电器的连接、固放电距离,并能在雨天阻
断水流,以保证绝缘子在恶劣的气候环境中可靠的工作。

穿墙套管用于母线在屋
内穿过墙壁和天花板以及从屋内向屋外穿墙时使用,6~35KV为瓷绝缘,60~
220KV为油浸纸绝缘电容式。

(五)电流互感器的配置和选择
1、参数选择。

技术条件:正常工作条件下,一次回路电流,一次回路电压,二次回路电流,二次回路电压,二次侧负荷,准确度等级,短路稳定性——动稳
定倍数,热稳定倍数承受过电压能力——绝缘水平,泄露比。

环境条件:环境温度,最大风速,相对湿度。

2、型式选择。

35kV以下的屋内配电装置的电流互感器,根据安装使用条件
及产品情况,采用瓷绝缘结构或树脂浇注绝缘结构。

35kV以上配电装置一般采用油浸式绝缘结构的独立式电流互感器,在有条件时,如回路中有变压器套管,穿
墙套管,应优先采用套管电流互感器,以节约投资,减少占地。

110KV侧CT的选择,根据《设计手册》35KV及以上配电装置一般采用油浸
瓷箱式绝缘结构的独立式电流互感器常用L(C)系列。

出线侧CT采用户外式,用于表计测量和保护装置的需要准确度。

当电流互感器用于测量、时,其一次额定电
流尽量选择得比回路中正常工作电流的1/3左右以保证测量仪表的最佳工作、并
在过负荷时使仪表有适当的指标。

根据 >
>
选择型号为LCWB6-110W型。

35KV侧CT可根据安装地点和最大长期工作电流选LCZ--35系列CT (六)电压互感器的配置和选择
1、参数选择。

技术条件:正常工作条件下一次回路电压,一次回路电流,二次负荷,准确
度等级,机械负荷。

环境条件:环境温度,最大风速,相对湿度,海拔高度,地震烈度。

2、型式选择。

6~20kV配电装置一般采用油浸绝缘结构,在高压开关柜中或
在布置地位狭窄的地方,可采用树脂浇注绝缘结构。

当需要零序电压是,一般采用三相五住电压互感器。

35~110kV配电装置一般采用油浸绝缘结构电磁式电压互感器。

110kV侧PT的选择。

《电力工程电气设计手册》248页,35-110KV配电装置一般采用油浸绝缘结构电磁式电式互感器,接在110KV及以上线路侧的电压互感器,当线路上装有载波通讯,应尽量与耦合电容器结合。

统一选用电容式电压互感器。

35KV及以上的户外装置,电压互感器都是单相的出线侧PT是当首端有电源时,为监视线路有无电压进行同期和设置重合闸。

准确度测量计算与保护用的电压互感器,其二次侧负荷较小,一般满足准确度要求,只有二次侧用作控制电源时才校验准确度,此处因有电度表故选编0.5级。

PT与电网并联,当系统发生短路时,PT本身不遭受短路电流作用,因此不校验热稳定和动稳定。

参考文献:
1董安平;张雪原;邓明丽;陈纪刚;吴广宁;;直供方式下综合地线对牵引回流的影响[J];西南交通大学学报;2010年01期
2张文欣;;英达感应式锌锅电控原理与应用分析[J];中国高新技术企业;2010年03期
3方东华;;绝缘棒改造为变电设备带电除冰工具的方法及注意事项[J];中国高新技术企业;2010年06期。

相关文档