Moreover, our store provides various types of classic sample texts, such as work reports, contract agreements, insights, speeches, rules and regulations, job responsibilities, operating procedures, plans, blessings, and other sample texts. If you want to learn about different sample formats and writing methods, please pay attention!

电工作业工作规程(15篇范文)

【第1篇】电工作业工作规程

1.电工应持证上岗,非电工人员禁止从事电气作业。

2.安拆作业前,电工人员应仔细研读设备的电气线路图以及电气部件的安装方法、顺序以及步骤,熟练掌握电气工作原理。

3.机械拆装前,电工应全面检查设备的电气线路、电气部件、限位开关、绝缘和接地情况并符合安全使用要求,确保电气线路工作正常可靠。

4.严格按规定的技术标准进行电气安装和调试工作,对安装好的机械设备,要做好机身接零接地工作,要仔细调整各安全限位装置使之动作灵敏可靠。

5.作业中要认真遵守电气、机械、高空作业安全规程,防止触电、坠落、挤伤故的发生,同时要注意保护协同作业人员的安全。

【第2篇】矿井大型设备维修电工作业安全操作规程

1.上班前不准喝酒、严格遵守工种岗位责任制,上班时不得干与本职无关的工作,遵守本操作规程及《煤矿安全规程》有关规定。

2.不得带电检修、搬迁电气设备、电缆和电线。检修或搬迁前,必须切断电源,挂好停电牌,并采取防止自转和自滑的措施。

3.在井下瓦斯浓度超过1、%时,禁止进行电气检修作业。当电气设备附近20 米内的瓦斯浓度达到1.5 %时,必须停止工作,切断电源,撤出人员,及时汇报有关部门,进行处理。

4.高空或井筒作业时,必须佩戴安全帽和保险带,保险带应扣锁

在安全牢靠的位置上。

5.需要变配电所的值班人员进行操作停送电的检修项目,停送电时,必须严格执行“工作票”制度,并设专人联系停送电,严禁带电作业。

6.无论高压、低压供电系统停电作业,作业前必须挂“停电作业”牌,并进行验电、放电,接临时地线等项安全措施。

7.在电气线路、电气设备未经验明确实无电前,一律视为有电,在未做好安全措施前,不准用手摸带电体。

8.两个或两个以上工种联合作业时,必须指定专人统一指挥。严禁在他人停电作业的线路上或设备上擅自进行工作,需要时应另行办理手续。

9.在试验采用新技术、新工艺、新设备和新材料时、应制定相应的安全措施,报领导批准。

10.作业前对所用工具、仪表、保护用品进行认真检查、调试,确保准确、安全、可靠。

11.检修负责人应向检修人员讲清检修内容、人员分工及安全注意事项。

12.作业前要搞清整个供电系统各部的电压等级,使用与电压等级相符的合格的验电笔时,要逐渐接近导体。

13.在进行定期检修或大修设备前,应按照作业计划,做好相应的准备工作。

14.需要对6 千伏以上高压电气设备检修作业时,还必须遵守“高

压设备作业规程”。

15.操作高压电气设备时,必须戴合格的绝缘手套、并穿电工绝缘靴或站在绝缘台上,由一人操作,一人监护,在停电后的开关上,挂上“有人工作,禁止合闸”的停电警示牌。

16.对所规定的日、周、月检内容按时进行维护检修,不得漏检、漏项。

17.各种电气安全保护装置应按规定进行定期维修、试验和整定。

18.对所维修的电气设备应按规定进行巡回检查,并注意各部温度和有无异响,异味,异常震动。

19.注意各种仪表应指示准确(如电流表、电压表、功率表、电度表等),发现问题及时处理。

20.对高低压开关的保护装置应按规定进行定期整定。

21.注意检查变压器的声响和温度,变压器上层油温不应超过85 ℃。

22.检查电动机的运行情况,注意轴承温度,线圈温度,有无异响,异味等。

23.对提升机等大型设备的各项机电保护、后备保护、闭锁功能及相应的检测装置应定期检查试验,并保证动作灵敏可靠,指示正确。

24.向电气设备补充的绝缘油,应同原使用的绝缘油有相符的物理、化学

性能和不低于原使用油的电气耐压强度,电气设备绝缘油的更换和试验要做好记录(有特殊要求的电气设备,按产品说明书执行)。

25.在架空线路或电缆线路上工作前,必须将该线路可能来电的所有开关刀闸全部拉开,并加绝缘隔板,挂好停电警示牌。经验明无电后,对大地充分放电装设接地线时,必须先接接地端,后接导体端,接触应良好,拆除地线顺序相反。

26.各种安全保护装置、监测仪表和警戒标志,未经领导批准,不准随意拆除和改动。

27.经检修负责人和操作监护人共同确认无问题后,方可按操作顺序进行送电。

28.对检修后电气设备,机械保护进行测试和联合试验,确保整个系统保护灵敏可靠。

29.设备检修后在送电前要清点人员、工具、测试仪器、仪表和更换的材料、配件是否齐全。

30.对检修作业场所进行清扫,搞好设备和场所的环境卫生。

31.检修后的设备状况,要由检修负责人向操作人员交待清楚,由检修、管理、使用三方共问检查验收后,方可移交正常使用。

32.认真填写检修记录,将检修内容、处理结果及遗留问题与司机交待清楚,双方签字。

【第3篇】煤矿矿井大型设备维修电工作业操作规程

1.上班前不准喝酒、严格遵守工种岗位责任制,上班时不得干与本职无关的工作,遵守本操作规程及《煤矿安全规程》有关规定。

2.不得带电检修、搬迁电气设备、电缆和电线。检修或搬迁前,必须切断电源,挂好停电牌,并采取防止自转和自滑的措施。

3.在井下瓦斯浓度超过1、%时,禁止进行电气检修作业。当电气设备附近20 米内的瓦斯浓度达到1.5 %时,必须停止工作,切断电源,撤出人员,及时汇报有关部门,进行处理。

4.高空或井筒作业时,必须佩戴安全帽和保险带,保险带应扣锁在安全牢靠的位置上。

5.需要变配电所的值班人员进行操作停送电的检修项目,停送电时,必须严格执行“工作票”制度,并设专人联系停送电,严禁带电作业。

6.无论高压、低压供电系统停电作业,作业前必须挂“停电作业”牌,并进行验电、放电,接临时地线等项安全措施。

7.在电气线路、电气设备未经验明确实无电前,一律视为有电,在未做好安全措施前,不准用手摸带电体。

8.两个或两个以上工种联合作业时,必须指定专人统一指挥。严禁在他人停电作业的线路上或设备上擅自进行工作,需要时应另行办理手续。

9.在试验采用新技术、新工艺、新设备和新材料时、应制定相应的安全措施,报领导批准。

10.作业前对所用工具、仪表、保护用品进行认真检查、调试,确保准确、安全、可靠。

11.检修负责人应向检修人员讲清检修内容、人员分工及安全注意事项。

12.作业前要搞清整个供电系统各部的电压等级,使用与电压等

级相符的合格的验电笔时,要逐渐接近导体。

13.在进行定期检修或大修设备前,应按照作业计划,做好相应的准备工作。

14.需要对6 千伏以上高压电气设备检修作业时,还必须遵守“高压设备作业规程”。

15.操作高压电气设备时,必须戴合格的绝缘手套、并穿电工绝缘靴或站在绝缘台上,由一人操作,一人监护,在停电后的开关上,挂上“有人工作,禁止合闸”的停电警示牌。

16.对所规定的日、周、月检内容按时进行维护检修,不得漏检、漏项。

17.各种电气安全保护装置应按规定进行定期维修、试验和整定。

18.对所维修的电气设备应按规定进行巡回检查,并注意各部温度和有无异响,异味,异常震动。

19.注意各种仪表应指示准确(如电流表、电压表、功率表、电度表等),发现问题及时处理。

20.对高低压开关的保护装置应按规定进行定期整定。

21.注意检查变压器的声响和温度,变压器上层油温不应超过85 ℃。

22.检查电动机的运行情况,注意轴承温度,线圈温度,有无异响,异味等。

23.对提升机等大型设备的各项机电保护、后备保护、闭锁功能及相应的检测装置应定期检查试验,并保证动作灵敏可靠,指示正确。

24.向电气设备补充的绝缘油,应同原使用的绝缘油有相符的物理、化学

性能和不低于原使用油的电气耐压强度,电气设备绝缘油的更换和试验要做好记录(有特殊要求的电气设备,按产品说明书执行)。

25.在架空线路或电缆线路上工作前,必须将该线路可能来电的所有开关刀闸全部拉开,并加绝缘隔板,挂好停电警示牌。经验明无电后,对大地充分放电装设接地线时,必须先接接地端,后接导体端,接触应良好,拆除地线顺序相反。

26.各种安全保护装置、监测仪表和警戒标志,未经领导批准,不准随意拆除和改动。

27.经检修负责人和操作监护人共同确认无问题后,方可按操作顺序进行送电。

28.对检修后电气设备,机械保护进行测试和联合试验,确保整个系统保护灵敏可靠。

29.设备检修后在送电前要清点人员、工具、测试仪器、仪表和更换的材料、配件是否齐全。

30.对检修作业场所进行清扫,搞好设备和场所的环境卫生。

31.检修后的设备状况,要由检修负责人向操作人员交待清楚,由检修、管理、使用三方共问检查验收后,方可移交正常使用。

32.认真填写检修记录,将检修内容、处理结果及遗留问题与司机交待清楚,双方签字。

【第4篇】一般电工作业安全规程

1.电气作业人员必须经专业安全技术培训考试合格,发给许可证后,持证上岗、操作。徒工和其它非持证电工,必须在持证电工的监护和指导下才准进行操作。

2.电工应掌握电气安全知识,了解安全责任区域的电气设备性能,熟悉触电急救方法和事故紧急处理措施。

3.电气作业应严格遵守安全操作规程和有关制度:

(1)工作票制度;

(2)操作票制度;

(3)工作许可制度;

(4)工作监护制度;

(5)工作中断、转移和终结制度;

(6)调度管理制度;

(7)危险作业(登高、带电、易燃易爆场所动火等)审批制度;

(8)临时线审批制度。

4.电工上岗、操作必须穿合格的绝缘鞋,必要时应戴安全帽及其它防护用品。所用绝缘工具、仪表、安全装置和工具须检查完好、可靠禁止使用破损、失效的用具,对不同电压等级、工作环境、工作对象,要选用参数相匹配的用具。

5.在供、配电设备和线路上作业,必须设人监护,监护人不得从事操作或做与监护无关的事情。

6.任何电气设备、线路未经本人验电以前,一律视为有电,不准触及。需接触操作时应切断该处的电源,经验电或经放电(对电容性

设施)之后验电合格,方能接触工作,对于与供配电网络相联系的部分,除进行断电、放电、验电外,还应挂接临时接地线,开关应上锁,防止停电后突然来电。

7.供配电回路停送电必须凭手续齐全的工作票和操作票进行。禁止约时停送电,动力配电箱的闸刀开关,禁止带负荷拉开或合闸,必须先将用电设备开关切断,方能操作。手工合(拉)刀闸应一次推(拉)足。处理事故需拉开带负荷的动力配电箱闸刀开关时,应采用绝缘工具,戴绝缘手套和防护眼镜或采取其它防止电弧烧伤和触电的措施。

8.未经电气技术负责人许可和批准改造电气设施的结构之前,电工不得改变电气设施的原有接线方式和结构。

9.各种电气接线的接头要保证导通接触面积不低于导线截面积,应尽可能采用紧固的压接或用工具扎接,不应用手扭接,线头不应突出,接头不得松动,防止带电体碰触屏护引起事故。

10.使用电动工具应遵守有关电动工具安全操作规程,使用行灯必须采用由隔离变压器供电的安全电压电源。

11.工作结束,应认真把电气设备使用方面问题向接班人员认真交接清楚,必要时,将有关事宜载入交接班记录。

【第5篇】蓄电池机车充电工作业操作规程

1.对于防爆特殊型蓄电池极柱的焊接,必须由经过专业培训并通过主管部门考核、取得《允许操作证》的人员担任。

2.配制硫酸电解液必须用纯水或蒸馏水。

3.配制电解液时必须穿戴胶靴、橡胶围裙、橡胶手套、护目眼

镜和口罩等防护用品。

4.在调合电解液时必须将硫酸徐徐倒入水中,严禁向硫酸内倒水(以免硫酸飞溅,烫伤工作人员)。

5.配制酸性电解液,遇有电解液烫伤时,应先用5 %的硫酸钠溶液清洗,然后再用清水冲洗。

6.配制碱性电解液,如果皮肤沾有碱液时,应先用3、%的硼酸水清洗,然后再用清水冲洗。

7.禁止在充电过程中紧固连接线及螺帽等。禁止将扳手等工具放在电池上。

8.碱性蓄电池使用300 ~350 个循环、酸性蓄电池使用6 个月应全部更换一次电解液并进行清洗,然后按初充电方式进行充电。

9.每组电瓶使用达30 个循环时,要进行一次全面检查,并均衡充电一次。

10.每周应测量一次泄漏电流,清洗一次特殊工作栓。

11.每周必须检查和调整每只蓄电池电解液的密度。

12.严禁占用机车充电。

13.在井行蓄电池充电室内测定电压时,可使用普通型电压表,但必须在揭开电池盖10 分钟后进行。

14.妥善保管好防火工具及消防器材,确保其完好、有效。

15.作业时应穿着规定的劳动保护用品。

16.认真执行岗位责任制和交接班制度。

17.认真检查电压表、点温计、密度计及温度计等检测仪表,确

保其灵敏可靠。

18.充电前必须先进行整体检查:

(1)电池装置外部应完好,铭牌和防爆标志齐全。

(2)电池装置的型号、额定工作电压。

19.换电瓶箱时,必须把电机车控制器手把拉回零位,取下手把,抽出电机车上的插销。

20.用推移方法换电瓶时,机车应与充电架对中,抽出电瓶箱与机车上的4 个固定串销,再平行推移到充电架上。

21.用吊车换电瓶时,应先检查吊车起重钩环、钢丝绳、制动闸与电动按钮,确认无误后再进行起吊。吊车升起后,严禁人员在起重物下行走或站立。

22.充电工作开始前应先检查充电机及充电机上的仪表,确认指示准确后再进行送电。

23.擦净电池箱盖上的灰尘、积水后,打开电池箱清洗干净。

24.每次充电前都应对电源装置进行检查,发现问题及时处理。

25.检查各电池间连接极柱是否正确,接线端子的连接是否牢固。

26.充电机电源的两极不得接反(电源的正极接电池的正极、电源的负极接电池负极)。

27.整流设备充电插销必须采用电源装置的专用插销,不得用其他物品代用。

28.清除放在电瓶上的任何工具、物品与脏物,打开全部电池旋塞。

29.充电前应再检查一次电源连接是否正确,观察电压表的指示值,并做好记录。然后启动整流器开始充电。

30.注意观察电池在充电过程中发生的变化(其中包括电解液的密度和温度、电池的端电压、充电电流的变化)如有异常情况应停电处理,不准电池带故障充电。

31.各种型号的电瓶及充电机,其充电方式、充电电流、充电时间、常规充电或快速充电,应按该产品说明书及有关技术文件执行。

32.在有80 %的单体电池电压升至2.4 伏时,方可改用第二阶段充电。当电解液冒出细密强烈气泡,而且达到2.5 伏以上,电压、比重稳定3、小时不变,即为充电完毕。

33.停止充电前各电池槽的比重:酸性为1.26 ±0.01、,否则,可用蒸馏水(当大于1.270 时)或比重为1.300 的稀硫酸(当小于1.250 时)调整;碱性为1.17 ~1.220、液面高出极板高度:酸性为10 ~20 毫米,碱性为15 ~30 毫米。

34.充电时电解液的温度不得超过下列规定:合成碱电解液43、℃;苛性钠电解液35 ℃;硫酸电解液45 ℃。温度超过时应立即停充或降低电流充电,待冷却后再充。测量温度时应不少于3、块电池。

35.注意连接线与极柱不得有过热或松动现象。

36.电池中电解液溢出时,应及时吸出、擦净。

37.监视充电设备的运行情况,遇有不正常现象立即停充,待处理后再充电。

38.在充电过程中,每小时必须检查一次电池电压、电流、液面、

比重和温度,并做好记录。

39.充电完毕必须停止1、~1.5 小时,待冷却后方可盖上电池旋塞。擦净注液口的酸碱迹,用清水冲刷后盖上电池箱盖,锁上螺栓。

40.每班工作结束后,须填写有关记录并打扫环境卫生、整理好工具和仪表后,方可交接班。

【第6篇】电工作业安全操作要点规程

电工作业安全操作要点(规程)

1、一般作业要求:

(1)线路上禁止带负荷接电或断电,并禁止带电操作。

(2)熔化焊锡块的工具要干燥,防止锡爆。

(3)喷灯不得漏油、漏气和堵塞,不得在有易燃、易爆的场所点火和使用。

(4)不得使用锡焊容器盛装电缆胶。高空浇注时,下方不得有人。

(5)有人触电时,应立即切断电源,进行急救。

(6)电气失火时,应立即切断电源,使用泡沫灭火器或干砂灭火。

2、设备和内线安装

(1)多台配电箱(盘)安装时,手指不得放在两盘的结合处,也不得触摸连接螺孔。

(2)管子煨弯用砂子必须烘干,装砂架子应搭设牢固,用机械敲打时,下面不得站人,管子加热时,管口前不得有人。

(3)管子穿线时,不得对管口呼唤、吹气,防止带线弹出勾眼。

3、外线工程作业:

(1)人工立杆时,叉木应坚固完好,配合用力要均衡;机械立杆时,两侧应设溜绳。立杆时坑内不得有人。

(2)登杆作业,安全带应拴于安全可靠处,不准拴于瓷瓶或横担上,工具、材料应用绳子吊递、禁止上下抛扔。

(3)杆上紧线应侧向操作,调整拉线时,杆上不得有人。单方向紧线时,反方向设置临时拉线。

(4)架线时在线路上每2-3km应接地一次,送电前必须拆除。遇雷雨时,应停止工作。

4、电气调试作业:

(1)进行耐压试验装置的金属外壳须接地,被试设备或电缆两端如不在同一地点时,另一端应有人看守或闭锁。人员撤离后,方可升压。

(2)对电力传动装置系统及高低压各型开关调试时,应将有关的开关手柄取下或锁上,防止合闸。

(3)雷电时禁止测定线路绝缘。

(4)电气材料或设备需放电时,应穿戴绝缘防护用品,用绝缘棒安全放电。

5、施工现场变配电和维修作业:

(1)单人值班时,不准超越现场变配电高压设备的遮拦和从事修理工作。

(2)在高压带电区域部分停电工作时,人体与带电部分应保持安

全距离,并需有人监护。

(3)变配电室、外高压中分及线路停电工作时应切断有关电源,操作手柄应上锁或挂指示牌,验电时应戴绝缘防护用品,检修完毕并全面检查无误后,方可拆除临时短路接地线。

【第7篇】煤矿内线电工作业操作规程

1.上班前不准喝酒,上班时不做与本职工作无关的事情,遵守有关各项规章制度。

2.检查、检修、安装、挪移机电设备时,禁止带电作业,必须遵循验电、放电、封线(装设短路地线)的顺序进行工作。

3.从事高压电气作业时,必须有2、人以上工作,操作高压设备时一人监护,一人操作,严格执行停送电制度。

4.同一供电系统和同一控制系统有多人同时工作时,必须注意互相之间的影响和相互之间的安全。凡因停送电影响他人安全的地点应按下列规定执行:

(1)一般不准同时作业,需要在停电的线路上进行多项作业时,应分别办理停电手续。

(2)必须有可靠的安全措施,以保障他人安全。

(3)必须同时工作时,要分别挂停电牌,并指定专门联系人负责联系各相关工作环节的进度,各环节均结束工作且人员撤离后方可送电。

5.修理后达不到防爆要求的电气设备严禁下井使用。

6.检修所用的零配件必须合格。

7.准备材料、配件、工具、测试仪器仪表及工作中其他使用的用具。

8.穿绝缘鞋,携带验电笔和绝缘工具。工作服要扎紧袖口。工作前先进行检查,经验电、放电、装设短路地线后再进行工作。

9.检修前、后的设备均需测试绝缘电阻。受潮或绝缘电阻低于规程要求的设备均应进行干燥处理。

10.使用起重工具时,应先检查手动葫芦、三角架、起重梁、卡子、绳套等工具的强度是否合乎要求,起重工具应牢固可靠。

11.操作高压开关应按下列顺序操作:

(1)送电合闸操作顺序应为:先合电源侧刀闸(隔离开关),后合负荷侧刀闸,最后合断路器。

(2)停电拉闸操作顺序应为:先断开断路器,后拉负荷侧刀闸(隔离开关),最后拉电源侧刀闸(隔离开关)。

12.检修电机、变压器吊芯抽转子时,必须防止碰撞线圈和损坏绝缘。变压器、电机更换线圈时,应在拆开后绘出草图,并记下有关数据,作为绕制新线圈的依据。

13.检修开关时,不准任意改动原设备上的端子序号和标记。要保护好防爆面,对失爆或不合格的防爆面要按规程要求进行修理。

14.设备检修后都要经过检查、试验,合格后填写检修试验记录,否则不准出厂。

15.操作电气设备时必须按下列规定执行:

(1)操作高压电气设备时必须执行工作票、操作票制度。应遵循

验电、放电、挂短路地线的顺序进行工作。装设短路地线应先接接地端,后接导体端。

拆短路地线时顺序与此相反。

(2)在由变电站(所)配出线路的各机房、车房内进行停送电工作时,应事先与变电站(所)联系,与变电站(所)的值班员配合好,按规定程序进行操作。

(3)在有可能反送电的开关上工作时,必须切断前一级反送电的电源开关。并在前后两级反送电的开关上悬挂“有人工作,禁止送电”的标志牌和装设短路地线。送电时必须联系好。由专人联系,专人送电。严禁不经联系盲目送电或约定时间送电。

(4)在有可能反送电的开关门上应加锁和悬挂“反送电开关,小心有电”的标志牌。

(5)操作刀闸(隔离开关)时应果断迅速。

(6)操作高压开关应符合规定的顺序,严禁带负荷操作隔离刀闸。

16.在继电保护、仪表等二次回路上工作时,必须遵守下列规定:

(1)严禁将带电的电流互感器二次侧开路,不得将二次侧永久接地点断开。

(2)短路电流互感器二次线圈必须用短路片或不小于 2.5 平方毫米的铜线。短路片和铜芯线必须紧固,接触良好。

(3)严禁将带电的电压互感器二次侧短路。

(4)在电流互感器和电压互感器上工作时,必须停电后再工作,如停母线电源确有困难时,也必须按规定顺序断开断路器及上下刀闸

(隔离开关),放置绝缘隔板后再进行工作。

(5)在二次回路上进行通电试验时,为防止由二次向一次反送电,应将二次回路断开,并取下二次回路的保险后,方准进行工作。

17.检查、检修各种大型固定设备的电气系统时,必须按下列规定执行。

(1)必须经矿主管领导或主管技术人员批准,方可进行。

(2)维修电工必须将检修、检查内容、时间和停电的范围及有关的注意事项向值班司机讲明,并做好检修、检查前的一切准备工作后,方准进行工作。

(3)检修、检查时,停、送电操作应由司机按操作顺序规定进行操作。维修电工做好监护工作,严禁违章作业。

18.两条线路需要并联或并联回路中的电缆由于事故被切断,进行重新接头或连接时均需定相。找好相序后才准许并联运行,其定相步骤和方法如下:

(1)准备一个一次电压与线路电压同等级的电压互感器和量程大于200 伏的电压表,互感器与电压表必须正常可靠。

(2)将电压表接于互感器二次侧。

(3)将一条线路停电,经验电、放电,确认无电压后,将线路中的一相用铜导线接于互感器的一个接线柱上。

(4)从电压互感器的另一个接线柱上引出一根导线,并将导线固定在高压试电笔验电的一端。操作人员戴绝缘手套、穿绝缘靴或站在绝缘台上,持验电笔手把。此时工作人员应与互感器和导线保持安全

距离,将停电的线路送电。

(5)将高压试电笔由远至近缓慢地去接触另一带电线路的其中一相,此时电压表的指示为零时表示被试相为相同相序。如果电压表指示有电压且电压值等于或大于100 伏时,被试相为不同相序。

(6)依上述方法试其他两相。三相试完找出相同相序后,做好标记。依方法再核对一次,准确无误后再准备接线。

(7)定好相后,两条线路按停送电的顺序停电,经验电、放电、挂接地线后进行接线并联。

(8)定相应选在场地宽敞、便于操作、停送电方便、与另一路电源停电开关较近的开关处工作。定相场地应设遮栏,禁止无关人员靠近。

(9)定相停送电时应由专人指挥,专人停送电。一人操作,一人监护。必须由有经验的人做此工作。每停一次电后必须验电、放电,确认无电压后再进行工作。

19.清点工具、材料、配件、仪器、仪表,做好检查、检修记录。

20.检修好的设备,经检查和试运转验收合格签字后上卡入账,入库保管或投入使用。

【第8篇】电工安全作业操作规程

1、适用范围

本规程规定了电工安全作业的一般规定。

本规程适用于公司电工作业。

2、主要内容

电工安全操作规程(通用5篇)

电工安全操作规程(通用5篇) 电工安全操作规程篇一 加强进网作业电工管理保障电网供用电平安规程依据《电力法》、《电力供应与使用条例》和《电工进网作业许可证管理方法》(电监会15号令),为加强进网作业电工的管理,规范电工进网作业许可行为,保障首都电网供用电平安,现就有关工作通知如下,请各单位遵照执行。 一、电工进网作业许可证是电工具有进网作业资格的有效证件,凡在电力用户的受电装置或者送电装置上,从事电气安 装、试验、检修、运行等作业人员,均应根据电监会15号令的规定取得电工进网作业许可证并进行注册。未取得电工进网作 业许可证或者电工进网作业许可证未注册的人员,不得进网作业。 二、国家电力监管委员会华北监管局负责北京地区电工进网作业许可的考试、受理、审查、打算、注册和日常监督检查;并 对电工进网作业行为进行监督检查。北京市平安生产监督管理部门对电工特种作业持证上岗状况进行监督检查。 三、对有关单位进网作业电工持证的要求:(一)电力用户单位高压变电所、凹凸压配电室,以及受送电装置的运行值班、维护检修等岗位的工作人员,均应取得许可证;倒闸操作时,持证操作人员数量要符合一人操作,一人监护的要求,并执行《电业平安工作规程》(dl408-91)的其他有关规定。 (二)供电企业内凡进入用户受送电装置上,从事电气安装、修理、试验、运行作业的。人员(包括农村电工),均应取得电工进 网作业许可证。 (三)自备电厂中在升压站等送出设施上从事电气安装、修理、试验、运行作业的人员,均应取得电工进网作业许可证。 (四)承装(修、试)电力设施企业内,凡进入用户受送电装置从事电气安装、修理、试验、运行作业的人员,均应取得 电工进网作业许可证。 四、电力及平安生产管理部门依法对从事进网作业人员进行下列检查: (一)进网作业人员是否取得《电工进网作业许可证》并是否已注册;(二)进网作业范围是否符合许可的作业范围;(三)进网作业行为、平安保障措施是否符合进网作业规定。 (四)电工作业人员是否持特种作业操作证上岗。 五、依据《电工进网作业许可证管理方法》(电监会15 号令)第四十一条:用人单位招用或者支配未取得电工进网作业许可证或者电工进网作业许可证未注册的人员从事进网作业,或者不根据规定协作许可机关监督检查的,国家电力监管委员会华北监管局将赐予警告,并处10000 元以下罚款。 六、根据《用电检查管理方法》,北京市电力公司协作有关部门详细开展北京地区电工进网作业许可执行状况的宣扬、检查及监督整改工作。 电工安全操作规程篇二 一、工作前,必须佩戴和使用符合国家标准或行业标准的劳动保护用品和用具。 二、操作人员必须掌握触电急救方法。 三、必须保持变配电设备的完好状态,严格按照规定巡视巡查,发现问题及时上报并配合维修人员及时修复,严禁设备带病作业。

电气维修工安全操作规程(15篇范文)

电气维护和修理工安全操作规程(15篇范 文) 【第1篇】电气维护和修理工安全操作规程 1、电修人员必须具备电路基础学问,严格遵守《电工安全操作规程》谙习设备安装位置、特性、电气掌控原理及操作方法,不允许在未查明故障及未有安全措施的情况下盲目试机。 2、在现场维护和修理时必须有两人以上,不允许单人操作。 3、在使用仪表测试电路时,应先调好仪表相应档位,确认无误后才略进行测试。 4、维护和修理设备时,必须首先通知操作人员,在停车后切断设备电源,把熔断器取下,挂上标示牌,方可进行检修工作。检修完毕应适时通知操作人员。 5、电器或线路拆除后,可能通电的线头必须适时用绝缘胶布包扎好,确保安全稳妥。 6、非专职人员,不得装拆、处置计算机系统的cpu、电源板、输入组件、输出组件,以保证计算机系统安全牢靠。 7、任何电器设备未阅历电,一律视为有电,不准用手触及。 8、禁止使用一般铜丝替换熔断器。 9、每次维护和修理结束时,必须清点所带工具、零件,清除工

作场所全部杂物,以防遗失和留在设备内造成事故。 10、临时工作停止电源后或每班开始工作,都必须重新检查电源,确定已断开,并验明无电,才略操作。 11、电气设备发生火灾时,要立刻切断电源,并使用四氯化碳 或二氧化碳灭火器灭火,严禁带电用水或用泡沫灭火器灭火。 【第2篇】电气维护和修理安全操作规程5 21.每台设备必须用单独导线接地或接零,禁止串联。严禁将铁管、设备外壳或其他接地线,做为单相设备的零线。 22.检修行车,肯定要有指定的梯口上车,严禁走轨道、钢梁, 事先肯定要与车间负责人取得联系。行车司机应作监护,如必须走 钢梁时,工作前必须实行停电、验电、挂牌、短路接地等安全措施,并需有人警戒。 23.若发觉工作人员触电,应快速、安全地使其脱离电源,切勿 用手去拉,并视触电情况,进行相应的救助(如人工呼吸,请医生 诊治等)。 24.工作完毕后,清理好现场,做到文明生产。 【第3篇】机修与机床电气维护和修理工安全操作规程 1、使用工具必须齐备、完好牢靠,禁止使用有裂纹、带毛刺、 手柄松动等不符合安全要求的工具。

电工操作规程(精选15篇)

电工操作规程(精选15篇) 电工操作规程 1 1.电工需经过专业的综合培训,合格后方可持证上岗。 2.尽量不要带电工作,如果必须带电工作时,应采取必要的安全措施,入站在橡胶上或穿绝缘胶鞋,并须有专人监护等。 3.各种电动设备,尤其是移动式电动设备,应建立经常的(每次使用前)与定期的检查制度。入发现故障或与有关规定不符时,应及时加以处理。 4.严禁使用导线头上不带插头的灯具和电器设备。 5.湿手赤脚不准去触电器开关及其他电器设备。 6.开关设备的要求: 1)开关的类型和容量大小的选择,应根据不一样环境,不一样容量的值班来决定。 2)直接用手操作的闸刀开关必须是防护式或封闭式。 3)开关应垂直安装,并应由上至下的方向拉开电源。在断开时,闸刀应无电,以保证不带电换保险丝。 4)开关安装的高度,对地距离在1.5m左右,不得低于1.2m. 5)照明拉线开关应装在火线上。 6)开关的金属外壳应采取保护接零线或保护接地。 7.对插座的要求 1)不一样的电源或不一样电压的插座应有明显标志。 2)插座应与照明线分开安装,以专用线控制。 3)插座只允许供容量2kw以下的设备使用,直接启用的电动机只允许 0.5kw以下。 4)220V单项设备应用三孔插销,380V三项设备应用司空插销。 5)36V以上插座应装在距地1.2m以上。 6)要根据生产场所的性质来选择插座的'型式。 8.保险丝的要求 1)保险丝容量选择:电动机不超过铭牌电流2.5倍。电热器及白炽灯按负

载电流选择,日光灯的负载电流为总瓦数除以电压一半。 2)不准使用铜丝及其他导体代替保险丝。 3)动力负荷电流大于60A、照明及电热负荷大于100A时,应采用管型保险丝。 4)额定电流10A至60A宜采用插型保险丝或塞型保险丝,有爆炸危险的地方可采用管型熔断器。 5)在中性线和接地线上禁止装设可熔断保险器。 9.电气照明要求 1)灯头对距离应不少于以下规定室外3m,生产车间2.5m,一般室内2m。低于这一要求时,应采用36V以下的安全电压。 2)局部照明,可移动照明应采用36V以下的安全电压。 3)螺旋灯头应采用具有安全护罩的胶木灯头,接线应正确。 4)36V以下低于照明变压应是栓线圈的,禁止采用自藕变压器或串联电阻来降压。 5)日光灯的镇流器应安装在明显易检修的地方,不准设于顶棚内。 10.手持电器用具均应采用胶皮绝缘导线,单相采用三芯,三相采用四芯。 电工操作规程 2 一、上岗前的检查和准备工作 1、上班前必须按规定穿戴好工作服、绝缘鞋、安全帽。 2、在安装或维修电气设备时,要清扫工作场地和工作台面,防止灰尘等杂物落入电气设备内造成故障。 3、班前班中不准饮酒,身体不适、心境不佳者不得上岗操作,工作时应集中精力,不得玩耍、打闹,不准做与本职工作无关的事,听从领导和指挥。 4、必须检查工具、测量仪表和防护用具是否完好。 二、安全礼貌操作 1、在全部或部分停电的设备上工作,必须落实保证安全的组织措施和技术措施。 2、电工须持证上岗,严禁非电气作业人员装修电气设备和线路,排除故障

维修电工操作规程(10篇范文)

维修电工操作规程(10篇范文) (经典版) 编制人:__________________ 审核人:__________________ 审批人:__________________ 编制单位:__________________ 编制时间:____年____月____日 序言 下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢! 并且,本店铺为大家提供各种类型的经典范文,如工作报告、合同协议、心得体会、演讲致辞、规章制度、岗位职责、操作规程、计划书、祝福语、其他范文等等,想了解不同范文格式和写法,敬请关注! Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! Moreover, our store provides various types of classic sample texts, such as work reports, contract agreements, insights, speeches, rules and regulations, job responsibilities, operating procedures, plans, blessings, and other sample texts. If you want to learn about different sample formats and writing methods, please pay attention!

电工作业工作规程(15篇范文)

电工作业工作规程(15篇范文) (经典版) 编制人:__________________ 审核人:__________________ 审批人:__________________ 编制单位:__________________ 编制时间:____年____月____日 序言 下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢! 并且,本店铺为大家提供各种类型的经典范文,如工作报告、合同协议、心得体会、演讲致辞、规章制度、岗位职责、操作规程、计划书、祝福语、其他范文等等,想了解不同范文格式和写法,敬请关注! Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! Moreover, our store provides various types of classic sample texts, such as work reports, contract agreements, insights, speeches, rules and regulations, job responsibilities, operating procedures, plans, blessings, and other sample texts. If you want to learn about different sample formats and writing methods, please pay attention!

电工安全操作规程(大全)

电工安全操作规程(一) 1、运行、检查、检修电器设备,必须严格执行和遵守工南钢、电业安全工作规程,严格执行安全操作规程和制度。 2、电工应基本掌握电器安全知识,包括高压、低压、直流、交流电子技术等,必须持证操作,未经培训和考试不合格者不得独立操作。 3、大项目检查时,必须要工作处做好安全措施。 4、检查、维修电器设备时,应有人监护,严禁独立一人作业。 5、检查、维修设备时,必须严格遵守南钢的有关安全规定,办理有关手续后方可操作,切断电源,进行验电程序,挂上“在检修中,严禁合闸”警示牌,确认无电并采取短路接地措施;确认检修完毕,清理现场后,应由停电挂警告牌者取下,按程序恢复送电。 6、电工操作者和检修者在工作前,应验明劳保用品和工具是否符合绝缘安全要求,严禁侥幸作业。 7、凡需用行灯照明时,必须采用安全电压36V及以下。使用保险必须符合电业技术设计要求,严禁用不同规格、替用。 8、一切电气设备的金属外壳和支架,必须有良好的安全保护装置。 9、对正在运行的电器设备,发生或未发生不正常现象一律不准带负荷拉、隔离开关。 10、电气设备的保护装置不得随意变动或拆除,不得更改其整定好的设计参数,必须定期做预防性检验及绝缘防护用品的预防性试验。 11、电工必须具备必要的电气安全救护,防火知识,掌握触电后的紧急救护法及电火灾扑救方法。 12、熟知电气用消防器材,电工随时可用会用。 13、一般情况下,在电器设备上工作均应停电后操作。必须带电作业时,要采取安全措施,按带电作业规程操作。 14、严格按电气设备的安装技术进行安装及维护。电线、电缆、母线等电板导接头处要拧紧,绝缘包扎好,严禁有松动或破损裸露的现象。 15、对于电气设备的裸露部位(带电体)或旋转部位设置安全防护或防护遮拦,并挂牌显示。 16、外线登高电工必须严格遵守高空作业安全规程。 17、高压停电送电,必须得到有关主管方面的指令,方可按工作票制度,工作许可制度,工作监护制度,进行操作,拉闸时必须两人,操作者应听取监护者发布逐条操作命令,操作人员再背读命令无误后再操作。 18、谨防静电危害,做好静电安全措施,雷电时,禁止带电作业。 19、移动用电工具必须经南钢安检合格,并在有效期内使用。 电工作业安全操作规程(二) 一、在电工作业时,可能产生的危险有害因素:触电、物体打击、高处坠落。 (1)未经过相关培训,持证上岗,不具备相关的安全知识。 (2)检修作业前未按规定办理相关的安全措施导致触电。 (3)不按电工规定的劳动用品穿戴(绝缘鞋等)导致触电。 (4)高处作业不带安全帽、安全带,使用的梯台不符合相关安全要求导致高处坠落、物体打击。 (5)带电作业导致触电。 (6)检修作业前未做工作标识,无安全措施,误送电导致触电。 (7)在检修岗位不遵守相关岗位的安全规定,导致事故。 (8)不使用应该使用的绝缘手套、绝缘棒、绝缘鞋等操作导致触电。 二、为保证电工操作的安全,操作者应做到的防护措施: (1)操作者必须经过培训取证后方可上岗作业。 (2)检修作业前必须做好相关的安全措施(挂好接地、工作牌等) (3)按规范要求穿戴劳保用品。 (4)高处作业戴安全帽、系好安全带,检查使用的梯、台符合安全规定。 (5)严禁带电作业

低压电工操作规程3篇

低压电工操作规程3篇 1【第1篇】低压电工安全操作规程(7) 低压电工安全操作规程(七) 1.遵守电气安全技术操作规程《通则》有关规定。 2.不准在设备运行过程中拆卸修理,必须停运并切断设备电源,按安全操作程序进行拆卸修理。临时工作中断或每班开始工作前,都必须重新检查电源是否已经断开,并验明是否无电。 3.动力配电箱的刀开关,禁止带负荷拉闸。 4.电机检修后必须遥测相间及每相对地绝缘电阻。绝缘电阻合格,把皮带轮上紧方可试车。空载电流应不超过规定范围。 5.试验电机、电钻等,不能将其放在高处,需放稳后再试。 6.定期巡检、维修电气设备,应确保其正常运行,安全防护装置齐备完好。 7.凡是暂时拆除的电气设备的导线电源端必须用绝缘胶布包好,不得有裸露部分。对不再使用的电源管线应拆除。 8.熔断器熔丝的额定电流要与设备或线路的安装容量相匹配,不能任意加大。带电装卸熔体时,要戴防护眼镜和绝缘手套,必要时应使用绝缘夹钳,操作人站在绝缘垫上。 9.电气设备的保护接地或接零必须完好、合格。即:电气设备裸露的不带电导体(金属外壳)经接地线、接地体与大地紧密连接起来,称保护接地,其电阻一般不超过4欧姆。将电气设备在正常情况下不带电的金属部分与电网的零线相连接,称保护接零。在同一低压配电系统中,

保护接零与保护接地不许混用。 10.螺口灯头的开关必须接在相线上,灯口螺纹必须接在零线上。 11.监督执行在动力配电盘、配电箱、开关、变压器等各种电气设备的附近,不准堆放易燃易爆、潮湿或其它危及安全,影响维护检修的物品。 12.临时装设的电气设备,必须符合临时接线安全技术规程。 13.每次检修完工后,必须清点所用工具、材料及零配件,以防遗失和留在设备内造成事故。将检修情况向使用人交代清楚,并送电与使用人一起试车。不能由维修电工单独试车。 14.漏电保护器应定期清扫、维修,检查脱扣机构是否灵敏,定期测试绝缘电阻,阻值应不低于1.5兆欧,电子式漏电保护器不准用兆欧表测量相邻端子间的绝缘电阻。 15.低压停电时,按规定办理停电手续,并会同申请停电人去现场检查、验电、挂地线或设遮拦,在开关的操作把上挂“禁止合闸,有人作业”的警示牌。在同一线路上有两组或以上人员同时工作时,必须分别办理停电手续,并在此路刀闸把上挂以数量相等的警示牌。 16.工作完毕,作业人员检查、清理现场,待全部人员撤离现场,工作负责人填写工作终结并签字后交停电执行电工复查无误方可摘警示牌送电。遇有两组及以上人员作业时,必须在各组完全完工后,方可摘警示牌送电。 【第2篇】高低压电工操作规程办法 1、值班电工必须具备必要的电工知识,熟悉安全操作规程,熟悉供电

电工安全操作规程(大全)

电工安全操作规程 1、运行、检查、检修电器设备,必须严格执行和遵守工矿、企业、电业安全工作规程,严格执行各单位根据实际情况制定的电业,安全操作规程和制度. 2、电工应基本掌握电器安全知识,包括高压、低压、直流、交流电子技术等,必须持证操作,未经培训和考试不合格者不得独立操作。 3、大项目检查时,必须要专人负责分管停、送电、监督和指挥工作,并在工作处做好安全措施. 4、检查、维修电器设备时,应二人搭档,相互监护。 5、检查、维修设备时,必须严格遵守本单位制定的有关安全规定,办理有关手续后方可操作,切断电源,进行验电程序,挂上“严格合闸"警示牌,确认无电并采取短路接地措施;确认检修完毕,清理现场后,应由停电挂警告牌者取下,按程序恢复送电。 6、电工操作者和检修者在工作前,应验明劳保用品和工具是否符合绝缘安全要求,严禁侥幸作业。 7、凡需用行灯照明时,必须采用安全电压36V及以下。使用保险必须符合电业技术设计要求,严禁用不同规格、替用。 8、一切电气设备的金属外壳和支架,必须有良好的安全保护装置。 9、对正在运行的电器设备,发生或未发生不正常现象一律不准带负荷拉、隔离开关。 10、电气设备的保护装置不得随意变动或拆除,不得更改其整定好的设计参数,必须定期做预防性检验及绝缘防护用品的预防性试验。 11、电工必须具备必要的电气安全救护,防火知识,掌握触电后的紧急救护法及电火灾扑救方法. 12、变电所、配电室、电器站等处,必须备用电气用消防器材,并要设专人保管,电工随时可用会用。 13、一般情况下,在电器设备上工作均应停电后操作.必须带电作业时,要采取安全措施,按带电作业规程操作. 14、严格按电气设备的安装技术进行安装及维护.电线、电缆、母线等电板导接头处要拧紧,绝缘包扎好,严禁有松动或破损裸露的现象。 15、对于电气设备的裸露部位(带电体)或旋转部位设置安全防护或防护遮拦,并挂牌显示。 16、外线登高电工必须严格遵守高空作业安全规程。 17、高压停电送电,必须得到有关主管方面的指令,方可按工作票制度,工作许可制度,工作监护制度,进行操作,拉闸时必须两人,操作者应听取监护者发布逐条操作命令,操作人员再背读命令无误后再操作. 18、谨防静电危害,做好静电安全措施,雷电时,禁止带电作业。 --—--—--—————--——-—--—-————-—---—--————-—--—-——---—————— -—---————-----——-——-—--—---—- 电工岗位职责和安全技术操作规程 (一)、岗位职责 1、负责本公司、本车间的高、低压线路、电机和电气设备的安装、修理与保养工作。 2、认真学习和掌握先进的电力技术,熟悉所辖范围内的电力、电气设备的用途、构造、原理、性能及操作维护保养内容。

电工安全操作规程和岗位职责(共8篇)

电工安全操作规程和岗位职责(共 8 篇) 第1 篇:电工岗位职责和安全操作规程 电工岗位职责和安全技术操作规程 (一)、岗位职责 1、负责本公司、本车间的高、低压线路、电机和电气设备的安装、修理与保养工作。 2、认真学习和掌握先进的电力技术,熟悉所辖范围内的电力、电气设备的用途、构造、原理、性能及操作维护保养内容。 3、严格遵守部颁电路技术规程与安全规程,保证安全供电,保证电气设备正常运转。 4、经常深入现场,巡视检查电气设备状况及其安全防护,倾听操作工的意见,严禁班上睡觉。 5、认真填写电气设备大、中修记录(检修项目、内容、部位、所换零部件、日期、工时、备件材料消耗等项)积累好原始资料。 6、按试车要求参加所修设备的大、中修的试车验收工作。 7、掌握所使用的工具、量具、仪表的使用方法并精心保管,节约使用备件、材料、油料。搞好文明生产,做好交接班记录。 (二)、安全操作规程 1、停电作业时,必须先用电笔检查是否有电,方可进行工作,凡是安装设备或修理设备完毕时,在送电前进行严格检查,方可送电。 2、在一般情况下不许带电作业,必须带电作业时,要做好可靠的安全保护措施,有二人进行(一人操作一人监护)。 3、雷雨天禁止高空、高压作业(禁止使用高压拉杆等),雨天室外作业必须停电,并尽量保持工具干燥。 4、高空作业必须佩戴好安全带、小绳及工具袋,禁止上下抛掷东西。 5、高空作业必须执行停送电工作票制度,做到无工作票不上杆,不交票不送电。 6、高空作业坚持"四不上":梯子不牢不上,安全用具不可靠不上,没有监护不上,线路识别不明不上。

7、带电工作时,切勿切割任何载流导线。 8、工作前必须检查工具是否良好,并要合理使用工具,工作前需首先检查现场的安全情况,保证安全作业。 9、任何电气设备拆除后不得有裸露带电的导体,清扫电动机线圈时,不得用洗油及尖锐金属以免损坏绝缘,设备检修时不得私自改变线路,安装必须按图纸施工。 10、凡是一般用(临时)的电器设备与电源相接时,禁止直接或搭挂,需装临时开关或刀闸。 11、使用高压拉杆时,须戴高压绝缘手套。 12、遇有严重威胁人身或设备的安全紧急情况时,可先拉开有关开关,事后向上级报告。 13、在设备进行维修前,必须将电源切断并加锁或悬挂"停电作业"牌。 14、对变压器维修时,高低压侧均需断开线路电源及负荷线,防止意外发生高压等危险。 15、300 安以上电流互感器,次级回路禁止带电作业。 16、电工安全用具装备应经常检查绝缘情况并规定每年一次耐压试验。 17、在带电操作换灯泡(防止电压不符灯泡爆炸)和切线等作业时,要戴防护眼镜。 (三)、技术操作规程 1、值班人员为了掌握、监视设备运转情况,及时发现异常和缺陷,应对所辖一切电气运转设备至少巡回检查二次。 2、如遇天气变化,高峰负荷,设备异常等情况,要适当增加特巡。 3、主要巡视检查维护项目: (1)、变压器、油色应透明不发黑,油面不过高过低,外壳无漏油现象和变形。 (2)、电气设备有无异常音响、臭味、变色、过热、冒烟等现象。 (3)、仪表、信号、指示灯、集控保护等是否处于良好状态。 (4)、变压器、电动机、电缆、元件等按其运动规定巡视。

安全用电操作规程范文(通用多篇)

安全用电操作规程范文(通用多篇) 第1篇: 安全用电操作规程 第1条所有配电箱均应标明其名称、用途,并作出分路标记。 第2条所有配电箱门应配锁,配电箱和开关箱应由持证的电工负责使用管理。 第3条所有配电箱、开关箱应每月进行检查和维修一次。检查、维修人员必须是专业电工。检查维修时必须按规定穿戴绝缘鞋、手套,必须使用电工绝缘工具。 第4条对配电箱,开关箱进行检查、维修时,必须将其前一级相应的电源开头分闸断电,并悬挂停电标志牌,严禁带电作业。 第5条所有配电箱、开关箱在使用过程中必须按照下述操作顺序:一、送电操作顺序为:总配电箱__分配电箱__开关箱二、停电操作顺序为:开关箱__分配电箱__总配电箱(出现电气故障的紧急情况除外) 第6条施工现场停止作业一小时以上时,应将动力开关箱断电上锁,并挂牌标志。 第7条开关箱的操作人员必须符合第27条要求,并熟悉开关电器的正确操作方法。 第8条配电箱、开关箱内不得放置任何杂物,并应保持经常维修和整洁。

第9条配电箱、开关箱内不得挂接其它临时用电设备,不准乱剪乱接电源线。 第10条熔断器的熔体更换时,严禁用不符合原规格熔体或铁丝、铜丝、铁钉等金属体代替使用。 第11条配电箱、开关箱的进线和出线不得承受外力。严禁挂晒衣服等生活用具,与金属尖锐断口和强腐蚀介质接触。 第12条电工安装、维修或拆除临时用电工程必须由电工完成。电工技术等级应同工程的难易程度和技术复杂性相适应。 第13条各类用电人员应做到: 一、掌握安全用电基本知识和所用设备的性能。 二、使用设备前必须按规定穿戴和配备好相应的劳动防护用品,并检查电气装置和保护设施是否完好。严禁设备带'病'运转。 三、停用的设备必须拉闸断电,锁好开关箱。 四、负责保护所用设备的负荷线,保护零线和开关箱。发现问题及时报告解决。 五、搬迁或移动用电设备,必须经电工切断电源并作妥善处理后进行。 第14条施工现场临时用电必须建立安全技术档案,内容共应包括: 一、临时用电施工组织设计的全部资料。 二、修改临时用电施工组织设计的资料。 三、临时用电技术交底与验收资料。

维修电工安全操作15篇

维修电工安全操作15篇 【第1篇】清理线维修电工钳工安全操作规范 1、工作前,必须穿戴好防护用品,电工随身携带电器维修工具并应遵守“电工安全操作规程”,非电气工作人员不得维修电气设备及线路。钳工应遵守“钳工安全操作规程”。开车前检查设备各工位是否复位,有无妨碍线运行的障碍物,如有异常,应通知停车检修。 2、严禁带电工作。停电检修设备应拉闸断电,挂牌示警。在进行电气作业前,必须验明确实无电后,才能工作;维修结束,确认设备和人员安全才能合闸。 3、、使用测电笔不准超出使用范围,一般测电笔只允许测试500伏以下的电压。 4、随时观察设备运行状况,电器运行状况,若出现异常应和操作者联系,停机并挂警示牌,排除故障,禁止在设备运行时调整、检修设备。一时难以排除的故障,应及时报告。当危害到人或设备的安全时,应果断按下急停钮,并及时报告段长等有关人员,同时作好事故记录。 5、维修抛丸机、热处理炉、机械手等设备时必须挂“有人工作,禁止合闸”警示牌,且要有人监护。 6、维护、检修气压、液压系统时应注意内部是否存残余压力,凡拆卸时会靠自重落下或移动的部件,必须进行可靠支撑,否则禁止随意拆卸。拆卸气管、油管时管口严禁对着人。禁止随意调整气压、油压。

7、在更换、维修热处理炉的循环风机时应注意保持距离,勿将身体的任意部位伸入风机内。需更换循环风机时,安装前要先检查,风机未装平稳或转动不畅,不得开启使用。 8、用人力移动机件时,必须要协调配合,统一指挥,以防止挤伤压伤。 9、清洗零件时,严禁吸烟。废油应倒在指定容器内,不准随便倒入地沟或地面。 10、在地沟维修设备时,必须两人以上,并与地面取得联系,互相配合,防止意外。 11、在地沟巡查时注意和皮带、辊道保持安全距离。每班应检查两次泵站电器、液压运行情况 12、在地沟、油泵房进行电气焊作业时,一律报动火作业审批,严禁随便动火。 13、登高检修时要系安全带,地面应有人监护,以防工具掉落伤人。禁止非工作人员在下面通行,作业区应拦上隔离装置,并标明“禁止通行”的牌子。 14、工作完毕,应清点工具是否有遗漏,防止遗忘在设备内部引发事故,通知操作者开车试运行,并清理工地,方可撤离。 【第2篇】制芯维修电工、钳工安全操作规范 1、工作前,必须穿戴好防护用品,电工随身携带电器维修工具并应遵守“电工安全操作规程”,非电气工作人员不得维修电气设备及线路。钳工应遵守“钳工安全操作规

电气维修安全操作规程5(15篇范文)

电气维修安全操作规程5(15篇范文) (经典版) 编制人:__________________ 审核人:__________________ 审批人:__________________ 编制单位:__________________ 编制时间:____年____月____日 序言 下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢! 并且,本店铺为大家提供各种类型的经典范文,如工作报告、合同协议、心得体会、演讲致辞、规章制度、岗位职责、操作规程、计划书、祝福语、其他范文等等,想了解不同范文格式和写法,敬请关注! Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! Moreover, our store provides various types of classic sample texts, such as work reports, contract agreements, insights, speeches, rules and regulations, job responsibilities, operating procedures, plans, blessings, and other sample texts. If you want to learn about different sample formats and writing methods, please pay attention!

电气安装工安全操作规程(15篇范文)

电气安装工安全操作规程(15篇范文) (经典版) 编制人:__________________ 审核人:__________________ 审批人:__________________ 编制单位:__________________ 编制时间:____年____月____日 序言 下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢! 并且,本店铺为大家提供各种类型的经典范文,如工作报告、合同协议、心得体会、演讲致辞、规章制度、岗位职责、操作规程、计划书、祝福语、其他范文等等,想了解不同范文格式和写法,敬请关注! Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! Moreover, our store provides various types of classic sample texts, such as work reports, contract agreements, insights, speeches, rules and regulations, job responsibilities, operating procedures, plans, blessings, and other sample texts. If you want to learn about different sample formats and writing methods, please pay attention!

电工工作制度15篇

电工工作制度15篇 【第1篇】电工日常巡检工作制度 一、天天当值电工上班后,对囫囵大楼、照明灯具、电器具、楼层配电柜举行检查,如发觉楼层或楼梯间有未关的灯具顺手关闭,节省用电,但需保证合理的照明。 二、如发觉灯具及其电器具损坏或有故障时,准时修理、更换或排解,如暂无备品、备件须准时申购准时更换、修理,不得延误、影响正常工作。 三、如客户需延时使用灯具、电器时,当值电工应作好交-班记录,准时通知下一班电工关灯或切断电源。 四、值班电工应定时巡查主楼凹凸压配电室、暖通空调、主机水泵管道,发觉问题准时处理。 五、如有客户入驻,值班电工应对晚间客户用电故障及大楼内发生的电气故障举行准时处理。 六、如有装潢工程队施工,电工应确保楼层平安用电,并保证施工现场平安。 七、定期检查和清扫配电柜,并有的确的平安防范措施。 八、全部修理电工与值班电工巡查都必需记录,对所更换灯具、电器具等,也必需有明确记录,每月举行统计。 【第2篇】防漏电、触电工作制度 1、井下不得带电检修、搬迁电气设备、电缆和电线。检修或搬迁前,

必需切断电源,检查瓦斯,在巷道风流中瓦斯浓度低于1%,再用与电源电压相适应的验电笔检验,检验无电后,方可举行导体对地放电。全部开关的闭锁装置必需牢靠地防止擅自送电,防止擅自开盖操作,开关把手在切断电源时,必需闭锁,并悬挂“有人工作,不准送电”字样的警示牌,惟独执行这项工作的人员才有权取下此牌送电。 2、操作井下电气设备应遵守《煤矿平安规程》之规定,非专职人员或非值班电气人员不得擅自操作电气设备,操作高压电气设备主回路时,操作人员必需戴绝缘手套,并穿电工绝缘靴或站在绝缘台上,手持式电气设备的操作手柄和工作中必需接触的部份必需有良好绝缘。 3、井下低压馈电线上,必需装设检漏庇护装置或有挑选性的漏电庇护装置,保证自动切断漏电的馈电线路。机电队必需加强井下低压检漏装置的检查、维护,发觉问题准时处理,保证检漏装置台台完好。天天必需严格执行上午9:30时漏电跳闸实验,并具体记录。 4、煤电钻必需使用设有检漏,漏电闭锁,短路,过负荷,断相,远距离起动和停止煤电钻功能的综合庇护装置。每班使用前,使用单位必需对煤电钻综合庇护装置举行一次跳闸实验,并有记录。机电队要加强电钻综保的检查、维护工作。任何单位和个人严禁将综保短接或塞死违章使用,一经发觉将郑重处理。如造成严峻后果,将依照有关法律、规矩依法查处。 5、井下电缆的选用、悬挂和衔接严格执行《煤矿平安规程》之规定。 6、简单遇到的暴露的带电体必需加装防护罩或遮拦等防护设施。 7、井下电气设备的庇护接地必需符合《煤矿平安规程》之规定及《煤

电气设备运行安全操作规程(15篇范文)

电气设备运行安全操作规程(15篇范文) (经典版) 编制人:__________________ 审核人:__________________ 审批人:__________________ 编制单位:__________________ 编制时间:____年____月____日 序言 下载提示:该文档是本店铺精心编制而成的,希望大家下载后,能够帮助大家解决实际问题。文档下载后可定制修改,请根据实际需要进行调整和使用,谢谢! 并且,本店铺为大家提供各种类型的经典范文,如工作报告、合同协议、心得体会、演讲致辞、规章制度、岗位职责、操作规程、计划书、祝福语、其他范文等等,想了解不同范文格式和写法,敬请关注! Download tips: This document is carefully compiled by this editor. I hope that after you download it, it can help you solve practical problems. The document can be customized and modified after downloading, please adjust and use it according to actual needs, thank you! Moreover, our store provides various types of classic sample texts, such as work reports, contract agreements, insights, speeches, rules and regulations, job responsibilities, operating procedures, plans, blessings, and other sample texts. If you want to learn about different sample formats and writing methods, please pay attention!

用电安全操作规程15篇

用电安全操作规程15篇 【导语】用电平安操作规程怎么写受欢迎?本为整理了15篇优秀的用电平安规程范文,为便于您查看,点击下面《名目》可以快速到达对应范文。以下是我为大家收集的用电平安操作规程,仅供参考,盼望对您有所关心。 名目 【第1篇】临时平安用电技术措施规程 临时平安用电技术措施 本系统采纳tn-s供电系统,在专用爱护线上无电流,此线特地承受故障电流,确保其爱护装置动作,但应留意其pe线不得断开,在供电末端应给pe线重复接地。 1. 施工现场的总配电箱和开关箱应至少设致命伤级漏电爱护器,而且两级;漏电爱护器的额定动作电流和额定动作时间应协作,使之具有分级爱护的功能。 2. 开关箱设置漏电爱护器,施工现场全部设备,除做爱护接零外,必需在设备负荷的首端处安装漏电爱护器。 3. 漏电爱护器应装设在配电箱隔离开关的负荷侧或开关的负荷侧。 4. 漏电爱护器的选择应符合gb6829-86《漏电电流淌作爱护器》的要求,开关箱内的漏电爱护器的额定漏电动作应不大于30ma额定漏电动作时间应小于0.1s。

5. 配电系统应设置室内配电屏和室外安排电箱或设置室外总配电箱和安排电箱,实行分级配电。 6. 动力配电箱与照明配电箱宜分别设置,如合置在同一电箱内,动力和照明线路应分路设置,照明线路设在动力开关上侧且箱内供电线路均有标识。 7. 开关箱应由末级安排电箱供电,开关箱内应一闸一漏,每台用电设备应有自己的开关箱,严禁用一个开关电器直接掌握两台设备。 8. 配电箱、开关箱应装设在干燥、通风常温场所,装设在用电设备或负荷相对集中的地区,安排电箱与天关箱不得超过30m,开关箱与其掌握的固定式用是设备的水平距离不宜超过3m。 9. 配电箱、开关箱四周应有足够两人同时工作的空间,其四周不得堆入任何有碍操作修理的物品。 10.配电箱应安装端正、坚固、移动式的箱体应装设在结实的支架上,固定式配电箱、开关箱的下皮与地面垂直距离大于 1.3m,移动式安排电箱、开关箱的下皮与地面的垂直距离为0.6-1.5m,箱体的下皮或优质绝缘材料制作。铁板的厚度大于2mm 11.配电箱、开关箱中导线的进线口和出线口应设在箱体下底面。 12.配电箱、开关箱内的各种电器按规定的位置坚固在安装板上,不得歪和松动。 13.工作零线应通过接线端子板连接,并应与爱护零线接线板分设。 14.配电箱后面的排线需排列整齐,成束绑扎,并用卡钉固定在盘板上,盘板引出及引入的导线应留出适当余度,以备检查

电工安全操作规程(大全)

电工安全操作规程(一) 1、运行、检查、检修电器设备,必须严格执行和遵守工南钢、电业安全工作规程,严格执行安全操作规程和制度. 2、电工应基本掌握电器安全知识,包括高压、低压、直流、交流电子技术等,必须持证操作,未经培训和考试不合格者不得独立操作。 3、大项目检查时,必须要工作处做好安全措施。 4、检查、维修电器设备时,应有人监护,严禁独立一人作业。 5、检查、维修设备时,必须严格遵守南钢的有关安全规定,办理有关手续后方可操作,切断电源,进行验电程序,挂上“在检修中,严禁合闸"警示牌,确认无电并采取短路接地措施;确认检修完毕,清理现场后,应由停电挂警告牌者取下,按程序恢复送电. 6、电工操作者和检修者在工作前,应验明劳保用品和工具是否符合绝缘安全要求,严禁侥幸作业。 7、凡需用行灯照明时,必须采用安全电压36V及以下。使用保险必须符合电业技术设计要求,严禁用不同规格、替用. 8、一切电气设备的金属外壳和支架,必须有良好的安全保护装置。 9、对正在运行的电器设备,发生或未发生不正常现象一律不准带负荷拉、隔离开关. 10、电气设备的保护装置不得随意变动或拆除,不得更改其整定好的设计参数,必须定期做预防性检验及绝缘防护用品的预防性试验. 11、电工必须具备必要的电气安全救护,防火知识,掌握触电后的紧急救护法及电火灾扑救方法。 12、熟知电气用消防器材,电工随时可用会用。 13、一般情况下,在电器设备上工作均应停电后操作。必须带电作业时,要采取安全措施,按带电作业规程操作。 14、严格按电气设备的安装技术进行安装及维护.电线、电缆、母线等电板导接头处要拧紧,绝缘包扎好,严禁有松动或破损裸露的现象。 15、对于电气设备的裸露部位(带电体)或旋转部位设置安全防护或防护遮拦,并挂牌显示. 16、外线登高电工必须严格遵守高空作业安全规程。 17、高压停电送电,必须得到有关主管方面的指令,方可按工作票制度,工作许可制度,工作监护制度,进行操作,拉闸时必须两人,操作者应听取监护者发布逐条操作命令,操作人员再背读命令无误后再操作。 18、谨防静电危害,做好静电安全措施,雷电时,禁止带电作业。 19、移动用电工具必须经南钢安检合格,并在有效期内使用. 电工作业安全操作规程(二) 一、在电工作业时,可能产生的危险有害因素:触电、物体打击、高处坠落。 (1)未经过相关培训,持证上岗,不具备相关的安全知识。 (2)检修作业前未按规定办理相关的安全措施导致触电。 (3)不按电工规定的劳动用品穿戴(绝缘鞋等)导致触电。 (4)高处作业不带安全帽、安全带,使用的梯台不符合相关安全要求导致高处坠落、物体打击。 (5)带电作业导致触电。 (6)检修作业前未做工作标识,无安全措施,误送电导致触电。 (7)在检修岗位不遵守相关岗位的安全规定,导致事故。 (8)不使用应该使用的绝缘手套、绝缘棒、绝缘鞋等操作导致触电. 二、为保证电工操作的安全,操作者应做到的防护措施: (1)操作者必须经过培训取证后方可上岗作业。 (2)检修作业前必须做好相关的安全措施(挂好接地、工作牌等) (3)按规范要求穿戴劳保用品. (4)高处作业戴安全帽、系好安全带,检查使用的梯、台符合安全规定。 (5)严禁带电作业