©2018 Lennox Industries Inc.Dallas, Texas, USA507765-01 02/2018EL196UHE SERIESGAS FURNACEUSER’S INFORMATIONMANUALFIGURE 1NOTE - This manual is the property of the homeownerand must be left with the equipment user.This furnace is equipped with safety devices that protect you and your property. If one or more of these devices is activated, furnace operation will stop. If your home is left unattended for an extended period of time, equipment op-eration must be checked periodically. If this is not possible, the water supply to the house should be shut off and the pipes should be drained. This will prevent prob-lems associated with a NO HEACAUTIONBefore attempting to perform any service or maintenance, turn the electrical power to unit OFF at disconnect switch.TOP CAP1 - K eep the furnace area clear and free of combustiblematerial, gasoline, and other flammable vapors and liquids. If it is installed in an insulated area, the furnace must be kept free of insulating material.Insulating material may be combustible.2 - A fter any heavy snow, ice or frozen fog event, thefurnace vent pipes may become restricted. Always check the vent system and remove any snow or ice that may be obstructing the plastic intake or exhaust pipes.3 - D O NOT obstruct air flow to unit. Unit must receivean unobstructed flow of combustion and ventilating air. DO NOT block or obstruct air openings on the furnace or air openings to the area in which the furnace is installed. Take care to maintain established clearances surrounding the furnace.4 - D O NOT store chlorine or fluorine products nearunit or introduce these products into the combustion air. These products can cause furnace corrosion.5 - D O NOT draw return air from a room where thisfurnace, or any other gas appliance (ie., a water heater), is installed. When return air is drawn from a room, a negative pressure is created in the room. Ifa gas appliance is operating in a room with negativepressure, the flue products can be pulled back down the vent pipe and into the room. This reverse flow of the flue gas may result in incomplete combustion and the formation of carbon monoxide gas. This toxic gas might then be distributed throughout thehouse by the furnace duct system.Your furnace is a gas appliance. It is critical that the gas supplied to the unit be completely burned to avoid the pro-duction of carbon monoxide gas. Complete combustion of the gas requires, but is not limited to, correct gas pressure and gas flow rate, adequate combustion, air, and properventing.Exposure to carbon monoxide gas can cause personal injury and even death to all occupants, including pets. Any item that is powered by or gives off heat from a combustion process (including lawn mowers, automobiles, and fire-places) has the potential to produce carbon monoxide gas. Because of this, Lennox recommends the use of a carbon monoxide detector in your home, even if you do not own gas appliances. Reliable detectors are available at reasonable retail prices. Contact your Lennox dealer for more details about this investment in your safety. Your furnace is designed to meet standards set by national agencies, and to operate safely when properly installed and maintained. However, the unit’s performance can be great-ly impacted by the individual installation and the operating environment. It is your responsibility to ensure that this appliance is maintained. Proper maintenance is critical for your safety and the satisfactory operation of the product. Lennox strongly recommends annual inspection and maintenance of this appliance. Contact your Lennox dealer for an inspection by a licensed professional servicetechnician (or equivalent).BEFORE PLACING THE UNIT INTO OPERATION, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. The gas valve on the EL196UHE will be equipped with a gas control switch. Use only your hand to move the switch. Never use tools. If the switch will not move by hand, do not try to repair it. Call a licensed professional service technician (or equivalent). Force or attempted repair may result in a fire or explosion.Placing the EL196UHE furnace into operation:EL196UHE units are equipped with an ignition system. Do not attempt to manually light burners on this furnace.Each time the thermostat calls for heat, the burners will auto-matically light. The ignitor does not get hot when there is no call for heat on units with this ignition system.Operating the Gas Valve (Figure 2)1 - S TOP! Read the safety information at the beginning ofthis section.2 - S et the thermostat to the lowest setting.3 - T urn off all electrical power to the unit.4 - T his furnace is equipped with an ignition device whichautomatically lights the burners. Do not try to light theburners by hand.5 - R emove the upper access panel.6 - M ove switch on gas valve to OFF. See figure 2.7 - W ait five minutes to clear out any gas. If you then smellgas, STOP! Immediately call your gas supplier from aneighbor’s phone. Follow the gas supplier’s instructions.If you do not smell gas go to next step.8 - M ove switch on gas valve to ON. See figure 2.FIGURE 29 - R eplace the upper access panel.10 - T urn on all electrical power to the unit.11 - S et the thermostat to desired setting.NOTE - When unit is initially started, steps 1 through 11 may need to be repeated to purge air from gas line.12 - I f the appliance will not operate, follow the section“Turning Off Gas to the Unit” and call your licensedprofessional service technician (or equivalent). Turning Off Gas to the Unit1 - S et the thermostat to the lowest setting.2 - T urn off all electrical power to the unit if service is tobe performed.3 - R emove the upper access panel.4 - M ove switch on gas valve OFF.5 - R eplace the upper access panel.ters should be inspected monthly. Clean or replace the filter(s) when necessary to ensure proper furnace oper -ation. A filter must be in place when the unit is operating. See table 1 for recommended filter sizes.NOTE - Use replacement filters that are similar in size and efficiency ratings to those originally provided by the installing contractor. Use of replacement filters with higher filtration ratings may restrict air flow to the furnace. This may result in reduced unit efficiency, as well as premature blower motor failure.TABLE 1Furnace Cabinet WidthFilter SizeSide Return Bottom Return 17-1/2”16 X 25 X 1 (1)16 X 25 X 1 (1)21”16 X 25 X 1 (1)20 X 25 X 1 (1)should inspect the complete system each season (heat-ing and cooling). The following maintenance procedures should only be conducted by a licensed professional ser-vice technician (or equivalent). Do not attempt to service the unit in any way.Venting SystemAnnually (before heating season) inspect furnace venting system, vent cap, heat exchanger, and burners for cor-rosion, deterioration, or deposits of debris. Remove any obstructions.Inspect the furnace for obvious signs of deterioration.Inspect the furnace venting system to make sure it is in place, physically sound, and without holes, corrosion, or blockage.Vent pipe must be clear and free of obstructions and must slope upward away from the furnace.Inspect the furnace return air duct connection to ensure duct is sealed to the furnace and terminates outside the space containing the furnace.Inspect the physical support of the furnace to guarantee that it is sound without sagging, cracks or gaps around base and it maintains seal between base and support.Inspect the condensate drain and trap for leaks and cracks. The drain and trap must also be cleaned and the trap must be filled with water.During a seasonal check the service technician will con-duct a combustion analysis. The technician will also in-spect the indoor blower, burner flames, electrical connec -tions and the venting system.BlowerCheck the blower wheel for debris and clean if necessary. The blower motors are prelubricated for extended bearinglife. No further lubrication is needed.Burner FlameElectrical1 - C heck all wiring for loose connections.2 - C heck for the correct voltage at the furnace (furnaceoperating).3 - C heck amp-draw on the blower motorMotor Nameplate__________Actual__________erate. Before calling, always check the following to be sure service is required:1 - C heck that electrical disconnect switches are ON.2 - C heck room thermostat for proper setting.3 - R eplace any blown fuses or reset circuit breakers.4 - G as valve should be ON.5 - A ir filter should not be plugged, which will limit airflow.6 - I s gas turned on at meter?7 - I s manual main shut-off valve open?Record the model and serial number of the furnace. These numbers are on the unit nameplate, which is located on the blower deck below the combustion air inducer.Serial Number __________________Model Number __________________unit, and contact a Lennox dealer for an inspection by a licensed professional service technician (or equiva-lent).• I f you repeatedly hear any new or unfamiliar sounds while your unit is operating, there may be a prob-lem. For example, poorly performing burners canproduce unfamiliar noises.• I f you smell any unusual odors, your unit may be operating improperly. For example, units can giveoff unfamiliar odors if components are required tooperate in abnormal conditions.• L ook for visible signs of a malfunctioning unit. Ex-amples include unusual amounts of condensate onwindows inside your house, visibly burnt compo-nents or unusual dirt or rust accumulations on thevent pipe or in the unit.• I f you experience headache, nausea, fatigue, or dizziness, the cause could be exposure to carbonmonoxide gas. This is often misdiagnosed as theflu because symptoms are similar. If you suffer fromflu-like symptoms that are exaggerated at home,but seem to subside while you are away from thehouse, exposure to carbon monoxide could be thecause.Your vigilance may pay off in early detection of a problem before either personal injury or property damage occurs. Do not hesitate to contact a qualified service technician asan investment in your well being.At the beginning of each heating season, and to comply with the Lennox Limited Warranty, your system should be checked as follows by a licensed professional service technician (or equivalent).1 - C heck wiring for loose connections, voltage atindoor unit and amperage of indoor motor.2 - C heck the condition of the belt and shaft bearingsif applicable.3 - I nspect all gas pipe and connections for leaks.4 - C heck the cleanliness of filters and change ifnecessary (monthly).5 - C heck the condition and cleanliness of burners andheat exchanger and clean if necessary.6 - C heck the cleanliness of blower assembly andclean the housing, blower wheel and blower motorif necessary.7 - I nspect the condensate drain and trap for leaks andcracks. The drain and trap must also be cleanedand the trap must be primed with water. Inspect therubber hoses connected to the pressure switches forcracks or loose connections, replace as necessary.Remove the rubber hoses from the cold end headerbox and inspect for any blockage, clean as needed.If strainers are installed in the hoses remember toremove and clean before reinstalling the hoses.8 - E valuate the heat exchanger integrity by inspectingthe heat exchanger per the AHRI heat exchangerinspection procedure. This procedure can beviewed at 9 - E nsure sufficient combustion air is available to thefurnace. Fresh air grilles and louvers (on the unitand in the room where the furnace is installed)must be properly sized, open and unobstructed toprovide combustion air.10 - I nspect the furnace intake and exhaust pipes tomake sure they are in place, structurally sound,without holes, blockage or leakage and theexhaust pipe is sloped toward the furnace. Inspectterminations to ensure they are free of obstructionsand are structurally sound. Inspect the furnacereturn air duct connection to ensure the duct issealed to the furnace. Check for air leaks on supplyand return ducts and seal where necessary.NOTE - After any heavy snow, ice or frozen fog event the furnace vent pipes may become restricted. Always check the vent system and remove any snow or ice that may be obstructing the plastic intake or exhaust pipes.11 - I nspect the furnace return air duct connection toensure the duct is sealed to the furnace. Check for air leaks on supply and return ducts and seal where necessary.12 - C heck the condition of the furnace cabinet insulationand repair if necessary.13 - P erform a complete combustion analysis during thefurnace inspection to ensure proper combustion and operation. Consult Service Literature for proper combustion values.14 - V erify operation of CO detectors and replacebatteries as required.Perform a general system test. Turn on the furnace to check operating functions such as the start-up and shut-off operation.1 - C heck the operation of the ignition system, inspectand clean flame sensor. Check microamps before and after. Check controls and safety devices (gas valve, flame sensor, temperature limits). Consult Service Manual for proper operating range. Thermal Limits should be checked by restricting airflow and not disconnecting the indoor blower. For additional details, please see Service and Application Note H049.2 - V erify that system total static pressure and airflowsettings are within specific operating parameters.3 - C lock gas meter to ensure that the unit is operatingat the specified firing rate for each stage of operation. Check the supply pressure and the manifold pressure on both low fire and high fire. If manifold pressure adjustment is necessary, consult the Service Literature for unit specific information on adjusting gas pressure. Not all gas valves areadjustable. Verify correct temperature rise.dealers. When ordering parts, include the complete fur-nace model number listed on the CSA International name-plate -- Example: EL196UH45XE36B. All service must be done by a licensed professional installer (or equiv -alent), a service agency, or the gas supplier.Cabinet PartsUpper access panel Blower access panel Top CapControl Panel Part s TransformerIntegrated control Door interlock switch Blower Parts Blower wheel MotorMotor mounting frameBlower housing cutoff plate Heating Parts Flame SensorHeat exchanger assembly Gas manifoldCombustion air inducer Gas valveMain burner cluster Main burner orifices Pressure switch IgnitorPrimary limit control Flame rollout switches。
壁挂炉说明书

壁挂炉说明书尊敬的用户:您好!感谢您选择我们的壁挂炉产品。
为了确保您能够安全、正确地使用本产品,充分发挥其性能并延长使用寿命,请您在使用前仔细阅读本说明书。
一、产品概述本壁挂炉是一种高效、节能、环保的供暖和热水供应设备,适用于家庭、公寓、别墅等场所。
它采用先进的燃烧技术和智能控制系统,能够根据您的需求自动调节供暖温度和热水供应量,为您提供舒适、便捷的生活体验。
二、产品特点1、高效节能采用先进的燃烧技术,热效率高,能够有效节省能源消耗。
智能控制系统可以根据室内外温度自动调节燃烧功率,避免能源浪费。
2、安全可靠配备多重安全保护装置,如过热保护、漏电保护、缺水保护等,确保您的使用安全。
严格按照国家安全标准设计和生产,经过严格的质量检测,品质可靠。
3、舒适便捷可以提供稳定的供暖和热水供应,温度均匀,舒适度高。
操作简单方便,您可以通过控制面板轻松设置温度、模式等参数。
4、环保静音燃烧过程中产生的污染物排放量低,符合环保要求。
运行时噪音低,不会影响您的正常生活。
三、技术参数以下是本壁挂炉的主要技术参数:|型号|额定功率(kW)|供暖面积(㎡)|热水产量(L/min)|燃气种类|电源(V/Hz)|||||||||具体型号|具体功率|具体面积|具体产量|天然气/液化气等|具体电压/频率|四、安装要求1、安装位置应选择通风良好、干燥、无腐蚀性气体和易燃物的地方,如厨房、阳台等。
安装高度应便于操作和维修,且距离地面不少于 15 米。
2、排烟系统必须安装专用的排烟管道,将燃烧产生的废气排出室外。
排烟管道的长度和弯头数量应符合安装要求,以确保排烟顺畅。
3、燃气管道燃气管道应采用符合国家标准的管材,并由专业人员进行安装和连接。
安装完成后,应进行气密性检测,确保燃气无泄漏。
4、水路连接供暖和热水管道的连接应牢固、密封,不得有漏水现象。
应安装过滤器和安全阀,以保护壁挂炉和系统的安全。
五、使用方法1、开机前准备检查燃气、水、电是否正常供应。
德国威能壁挂炉使用说明

德国威能壁挂炉使用说明引言:一、产品概述:德国威能壁挂炉是一种燃气供暖设备,采用了先进的燃烧技术和高效的加热系统,既能够提供温暖的空气,又能够为家庭提供热水。
其主要特点包括:简洁紧凑的设计、高效的能源利用、智能化的控制系统和全面的安全保护措施。
二、安装步骤:1.在选择安装位置时,请确保墙壁牢固且能承受足够重量,并在安装位置附近有适当的排气通风设施。
2.将威能壁挂炉安装在合适的位置,并将其稳固固定在墙壁上。
3.连接燃气管道和水管道,并确保连接处密封良好,没有泄漏。
4.通过电源插头将壁挂炉连接到电源。
三、操作指南:1.打开天然气阀门,确保天然气供应畅通,并确保壁挂炉通电。
2.将壁挂炉的温度调至所需温度。
大多数威能壁挂炉配备了温度调节器,用户可以根据需要进行调节。
3.等待一段时间,直到壁挂炉达到所设定的温度。
一般情况下,壁挂炉会自动运行和停止,以维持设定的温度。
4.如果需要热水,您可以打开对应的热水龙头。
壁挂炉会自动加热水源,当水温达到设定的温度时,会停止加热。
四、保养维护:1.定期清洗灰尘和杂物,保持壁挂炉的表面干净。
2.检查燃气和水管道的连接处是否有泄漏,并及时修复。
3.定期检查和更换壁挂炉的滤网和过滤器,确保炉内燃烧清洁。
4.定期检查壁挂炉的燃烧器和火焰是否正常,如有异常请及时维修。
5.如果长时间不使用壁挂炉,请关闭天然气阀门,切断电源。
五、安全注意事项:1.在使用壁挂炉之前,请仔细阅读产品说明书,了解使用方法和注意事项。
2.在使用壁挂炉时,请确保房间内有适当的通风和排气设施,避免一氧化碳中毒。
3.按照正常操作规程使用壁挂炉,不要擅自改动或拆卸设备,以免引发火灾或其他安全事故。
结论:。
扬子l1pb20壁挂炉说明书

《扬子l1pb20壁挂炉说明书》滁州扬子热能设备科技有限公司是中国扬子集团下属骨干科技型企业,总部位于安徽省除州市经济技术开发区。
主导产品有燃气壁挂炉,散热器等。
公司立足于环保、节能、新能源行业的发展,是集研发、制作、销售及进出口业务为一体的多元化科技型企业。
壁挂炉是耗燃气较大的家用电器,如何节能,大家都比较关心。
首先,应掌握真确的壁挂炉使用方法,不要总是频繁开启,越频繁开关越消耗燃气。
购买时还应选择高品质、信誉好、品牌大的燃气壁挂炉。
下面详细介绍扬子燃气壁挂炉使用方法,教你怎么正确使用扬子燃气壁挂炉。
扬子燃气壁挂炉使用方法介绍一、运行模式的选择由于标准的燃气壁挂炉,一般都是有采暖与卫生热水两种不同的运行模式,而在燃气壁挂炉的控制面板上也相应的存在着两个选择功能,在冬天时,我们可以使用燃气壁挂炉提供采暖与热水的功能,并且热水功能优先,或者是根据用户的使用情况来进行自动的切换,而在夏季,则燃气壁挂炉处于等机的状态,只有在使用热水的情况下进入热水模式。
扬子燃气壁挂炉使用方法介绍二、温度的控制燃气壁挂炉对于温度的控制一般是以恒温为主要的原则,在升温其地暖的水温一般保持在60度左右,暖气片的温度在80度,而对于恒温期则地暖保持在4 0度,暖气片的温度为60度,这是一种非常经济节能的运行模式。
扬子燃气壁挂炉使用方法介绍三、无人时的操作对于上班一族,往往家里会有无人时,如果将钢炉关闭,然后下班之后再进行高档位的急速加热,其实这是一种非常不科学的方法,不仅不节能,反而会浪费燃气,并且对于锅炉与暖气都有被冻坏的情况。
如果是居室内长期不居住,最好的方法就是把锅炉与暖气片内的水放掉。
扬子燃气壁挂炉使用方法介绍四、冬天防冻措施燃气壁挂炉可以长时间通电,对于寒冷的冬天,如查燃气壁挂炉已经充水,则必须对燃气壁挂炉设置防冻与准备足够的燃气,以免暖气片或者是水泵、换热器等因燃气的不足而被冻坏,而在对燃气壁挂炉设置防冻功能时,必需要保证家里的水、电、气的充足与畅通,然后进行定期的检查锅炉水压的情况,则最为经济的办法就是把燃气壁挂炉系统内的水给排出来,然后用气泵吹。
万家乐L1PB38-19P2说明书

万家乐L1PB38-19P2说明书万家乐L1PB38-19P2
基本参数
产品类型即热式燃气壁挂炉
燃气类别天然气,液化气
能效等级2级
显示方式LED数码显示
采暖温度30-80℃
燃气压力天然气/液化气:2000/2800Pa
水箱容积10L
采暖面积100-200㎡
采暖系统工作压力 0.3MPa
产热水能力卫生水温度调节范围:35-60℃
卫生热水产率19 L/min T=25K
卫生热水产率16 L/min T=30K
输入功率最高38KW,最低17KW
输出功率最高34KW,最低14.5KW
防水等级IPX4
其他性能供暖系统结构形式:封闭式
排烟方式:强制给排气
供暖模式:散热器/地暖
绝缘类型:1类
电源功率120W
电源 AC220V/50Hz
产品尺寸780×540×330mm
产品重量50kg
能源种类:天然气包装清单:壁挂炉整机、使用说明书、保修卡、膨胀螺栓、密封垫圈、排烟管垫片、烟管密封条、给排烟管(单独包装)售后服务:产品包修期限产品整机包修期为2年。
博途Gepard燃气壁挂炉说明

博途Gepard壁挂炉简介
博途Gepard壁挂炉由威能集团研发团队打造,采用先进的RNC平台技术,运用高品质的生产线管理流程,无论是核心生产组件的选择,还是零部件的试验创新,到整机的设计、测试,每一个环节均执行威能统一标准。
博途推出的Gepard系列燃气采暖热水炉新品均为欧洲进口,博途Gepard所有新品均可使用天然气,而且满足中国市场的各种使用环境。
Gepard系列壁挂炉外形结构紧凑,体积小巧,极尽简约,科技感十足。
一、3档手动调节水泵,可按实际采暖热水需求选择档位。
源自德国威能RNC技术平台,灵活的手动调节功能,随心所欲的采暖洗浴体验。
贴心的外置水泵联动功能,还能满足大阻力系统需求。
二、燃气阀性能稳定,噪音小,安全可靠。
平静的燃烧,稳定的运行,噪音小,采暖体验好。
三、供回水双温感, 精确控温,节约燃气。
主热交换器供水水管各1个温感,精确控温,节约燃气。
防冻、防超温多种保护功能让用户安心使用,轻松省钱。
四、小流量启动,适合高层水压低的使用情况。
数字化的热水流量系统完美控制水流水压,精准调节,出水温度恒定。
五、火排数量多,和空气预混更充分,燃烧效率更高。
先进的燃烧器设计,不浪费每一立方燃气,燃烧效率“杠杠的”,燃烧更充分更环保。
复合材质水路组件,热量损失小,不宜积聚灰尘。
每一个零部件的构成都是基于德国威能RNC技术平台试验创新的结果,机身内部设计精工细制。
天津神菱L1PB28-B使用说明书

天津神菱L1PB28-B使用说明书
消费者在使用壁挂炉时会遇到CO及氮氧化物等废气排放的问题,不仅影响环境,还会影响家人安全。
有了神菱壁挂炉,消费者就不必再担心了。
神菱壁挂炉采用全预混的燃烧方式,预先将空气和燃气进行最佳配比后进行充分燃烧,烟气排放物中氮氧化物NOX空前降低,为欧洲最低的5级排放。
普通壁挂炉为了保持设定温度会反复运行与停止,能源浪费不说,且影响机器使用寿命。
对此,神菱壁挂炉采用独有的AUTO变频科技(全球专利),根据用户采暖需求、温度感应装置监测进回水温度、室内温度和室内外温差,智能选择最节能、最舒适的加热功率及加热温度,让机器低耗高效运行,有效避免机器疲劳运行和能源损耗。
打开天然气阀门壁挂炉下的四根水管阀门全部打开安装了壁挂
炉程序控制器的住户,要把控制器的温度调高于室温,否则壁挂炉不会工作打开壁挂炉启动开关检查水压,及时补水;刚打开开关时,壁挂炉温度显示屏上会显示水压,如数字显示低于1.0bar,则须补水。
通常,正常水压在1.2bar—1.5bar之间供暖气温调至"*"挡或是3挡检查壁挂炉下方水管连接处以及其他暖气末端连接处是否渗水对暖
气片再进行一次放气,如果暖气局部不热或是听到水流的哗哗声都证明里面有气体未排出。
壁挂炉使用说明

6. 壁挂炉的注水
重要事项:在壁挂炉不运行时,应定期检查压力表(14-图3)上读取的水压是否在0.7-1.5bar之间。一旦发现超 压应立即打开壁挂炉排水阀,如果水压过低,应打开注水阀(图3)。 我们建议您应慢慢地打开注水阀,以便空气释放。 操作时夏季/冬季选择旋钮必须处于“关闭”(0)位置。
备注:如果水压经常频繁下降,请联络特约技术援助服务中心进行检查维修。
2
目录
1.安装前须知
4
2.启动前须知
4
3.壁挂炉的启动
5
4.卫生热水温度的调节
5
5.室内温度的调节
6
6.壁挂炉的注水
6
7.壁挂炉的关闭
6
8.燃气种类的更换
6
9.长时间停机时系统的防冻保护
7
10.安全装置的指示---处理方法
7
11.常规保养说明
7
BAXI s.p.a.是欧洲生产家用采暖及生活热水设备(燃气壁挂炉、落地炉及电热水器)的最具实力的厂家之 一,公司根据 UNI EN ISO9001 规定,已获得 CSQ 认证,此认证确保了 BAXI S.p.A Bassano Del Grappa 意大利工厂(您所购壁挂炉的生产厂)的质量体系达到了 UNI EN ISO 9001 标准要求,UNI EN ISO 9001 标准是关于生产各阶段及产品生产和发货过程中人员操作的最严格的标准。
1. 卫生水路系统: 1.1. 如果水质硬度超过20 °F(1 °F=每升水含10mg碳酸钙),建议加装一个符合现行规定的多磷酸盐计量投配
器或者具有同等效果的系统。
1.2. 在装置安装以后及使用之前,必须对设备进行一次细致的清洁。
2. 供暖水路系统 2.1. 新设备
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
天然气壁挂炉使用说明书
天然气壁挂炉是现代家庭采暖和热水的首选设备之一,它有着安全、高效、环保等优势,但是在使用过程中也需要注意一些事项,下
面我们就来详细介绍一下。
一、安全使用
1、安装
天然气壁挂炉需要安装专业人员进行安装。
安装时需选择平整、
通风好的位置,并避免燃气和电器的干扰。
2、操作
天然气壁挂炉操作非常简单,但是需要根据使用说明进行正确操作。
首先,需要开启家庭天然气供应门,并打开燃气开关;其次,将
壁挂炉开关打开,选择热水、采暖模式;最后,等待壁挂炉自动点火,即可开始使用。
3、维护
天然气壁挂炉需要定期清洗和维护,以保证其正常运行和安全。
建议选择专业维修公司进行定期检查和维护,如有异常情况及时进行
处理。
二、高效节能
天然气壁挂炉采用高效能的燃烧方式,具有很高的能量利用率,可大幅节省能源开支。
此外,壁挂炉还采用了智能控制系统,可进行精准的温度调节,达到舒适的室内温度。
三、环保健康
天然气壁挂炉无烟、无味,不产生垃圾,对环境污染非常小。
而且壁挂炉的燃气燃烧后会产生少量的水蒸气和二氧化碳,对人体健康影响较小。
总之,天然气壁挂炉是现代家庭采暖和热水的理想选择,使用时应注意安全、高效、环保等方面,才能保证其正常运行和长久使用。