CJS-1200TA1;CJS-1200TB1;CJS-1201TA1;CJS-1201TB1;中文规格书,Datasheet资料
迅达APMMR现场安装手册

迅达A P M M R现场安装手册SANY标准化小组 #QS8QHH-HHGX8Q8-GNHHJ8-HHMHGN#安装缩略图摘要本手册提供了在亚太区范围内使用脚手架安装300P MMR主要安装步骤的详细说明。
本手册为保密文件,并仅供授权的培训人员使用。
目录1 安全建议 (4)概要 (4)使用符号 (4)2 先决条件 (5)产品概述 (5)安装步骤 (7)专用工具 (9)3 施工现场准备工作 (10)4 导轨安装 (15)准备工作 (15)导轨支架安装 (15)导轨安装 (21)导轨基座 (21)导轨安装 (22)连接板校正 (24)5 Varidor 30AP C2 厅门入口安装 (25)门框预安装 (27)地坎支架 (30)门框和机械横梁 (31)地坎和护脚板 (35)门板 (36)C2井道互锁装置 (40)门解锁装置 (41)安装门重锤 (42)防护罩 (44)6 PMS420无齿轮机组安装 (45)机组支架 (47)安装PMS420无齿轮机组 (48)*手动应急操作选配装置 (51)制动器调整和制动力测试 (57)*曳引钢丝绳悬挂装置安装 (58)*安装限速器 (62)7 *安装GGM2-AP对重 (71)先决条件 (71)*机械安装 (72)*缓冲器支撑 (72)*对重校正 (73)*安全钳(选配) (74)*导靴 (76)油杯(选配) (79)*对重块 (79)*补偿链悬挂装置 (80)地震传感器(选配) (81)*调整和最后检查 (82)对重防护屏 (83)*对重防护屏后置 (83)*对重防护屏侧置 (84)8 安装轿厢架FRS9-AP/FRM9-AP (87)安装轿厢架FRS9-AP (87)FRS9-AP安全钳和导靴选配件 (98)FRM9-AP安全钳和导靴选配件 (99)9 安装曳引绳 (100)处理钢丝绳 (100)安装钢丝绳 (101)钢丝绳绳头安装 (105)检查钢丝绳张紧度和绳的润滑 (109)限速器钢丝绳 (110)10 轿厢P9KD-AP(CM)安装 (117)轿厢安装步骤 (118)*安装轿厢装璜 (134)安装满载、超载开关 (143)轿厢平衡装置 (144)11 V30 AP轿门安装 (145)11.1 C2轿门 (145)11.1.1 轿门机驱动 (146)11.1.2 轿门板 (147)11.1.3 轿门刀 (149)安装光幕(MiniMax光幕LVH) (151)12 安装缓冲器 (157)13 安装补偿链 (159)补偿链导向装置 (159)4-滚轮导靴 (159)2-滚轮导靴 (162)补偿链 (165)14 安装MX-GC (170)先决条件 (170)材料范围 (171)控制柜 (172)井道信息 (174)井道信息IGSI (174)绝对值线型井道信息系统 (190)控制柜内模块 (210)机房电缆 (211)井道电缆 (215)准备 (220)安装 (223)调整和最后检查 (229)OKR (231)随行电缆 (236)带IGSI和LONCIB的MX-GC,HQ<=70m (237)带IGSI和LONCIB的MX-GC,HQ>70m (238)带IGSI和LONIC/LONICK的MX-GC,HQ<=70m (239)带IGSI和LONIC/LONICK的MX-GC,HQ>70m (240)控制柜内的概述与名称 (241)15 VARIODYN VF44BR和VF88BR安装 (243)VARIODYN VF44BR安装 (243)VARIODYN VF88BR安装 (249)1 安全建议概要安全要求所有参与的安装人员必须熟悉并遵守公司以及当地的安全规范,特别要注意以下几点:照明必须充足,以保证安全生产。
LC1200系列PLC硬件功能说明书

资料编码:2304LC1200-3LC1200系列PLC硬件功能说明书!使用产品之前请仔细阅读产品说明书公司简介苏州市凌臣采集计算机有限公司成立于2006年,是一家本着与客户共赢、为客户创造方案价值的经营理念的企业。
为客户提供各种测试测量、运动控制、机器视觉、机器人等自动化设备的核心零部件和系统解决方案。
凌臣科技于2017年开始创立凌臣采集LCT品牌,研发了包括工控机、PLC控制器、EtherCAT步进驱动器、PCI/PCIe运动控制卡、远程IO模块、气动阀岛等产品,为我司的客户提供了更具性价比的方案解决。
凌臣科技十分重视研发的投入,目前员工总数270人其中研发技术人员占比超50%。
公司同时于2014年成立了基于PC-Base的“授人渔“自动化培训机构,为自动化行业培养了大量专业技术人才。
公司和ADLINK、ABB、ACS、TRIO、TOYO等知名企业保持着长期紧密的合作关系。
LC1200系列通用型运动控制器凌臣全新一代LC1200系列运动控制器,结合CODESYS工业自动化软件平台,将运动控制技术和信息化技术融合于一身,更好的服务于非标自动化,3C,光伏,物流,锂电...目录1产品概述 (4)2型号铭牌信息 (5)3.产品规格说明书 (6)3.1结构与尺寸规格 (6)3.2硬件配置与技术参数: (7)3.3软件配置与技术参数: (8)4.安装与固定 (10)4.1安装环境要求 (10)4.1.1安装环境 (10)4.1.2安装空间 (10)4.1.3安装注意事项 (10)4.2安装方法 (11)4.2.2将DIN导轨固定到控制柜内安装平面上 (11)4.2.3将连接好的模块组安装到导轨上 (12)4.2.4安装系统防护组件——尾板 (13)5.硬件介绍及接线 (14)5.1电源配线 (14)5.2CPU模块输入输出配线 (15)5.2.1接线注意事项 (15)5.2.2外部接线 (15)5.3CPU模块通信配线 (16)5.3.1线缆连接要求 (17)5.3.2通过工业以太网总线连接 (19)5.3.3通过RS485的串行通信连接 (20)5.3.4LC1200系列PLC以太网协议的通讯连接 (24)6.运行与维护 (28)6.1运行与停机操作 (28)6.2指示灯、复位键说明 (29)6.2.1指示灯应用说明 (29)6.2.2复位键操作说明: (29)6.2SD卡使用说明 (30)6.3例行维护保养 (30)1、产品概述这是一款面向通用应用场景,基于CODESYS标准平台开发的中型PLC,本机资源丰富,支持IO模块,支持IEC标准及PLCopen标准。
1200样本手册

TIA 博途产品范围总览 TIA 博途安装的系统要求
SIMATIC HMI 系列面板
附录 附录 1 — 中央处理单元接线图
— 扩展模块接线图 附录 2 — 通用技术规范 附录 3 — 订货数据
4
11 12 13 13 14 14 14
LOGO! 8
PROFIBUS DP / RS485
PROFINET / TCP/IP
I/O能力,程序大小,指令速度,通讯能力, ...
SIMATIC S7-1200
SIMATIC S7-1200 具有集成 PROFINET 接口、强大的集成工艺功能 和灵活的可扩展性等特点,为各种工艺任务提供了简单的通信和有
SIMATIC S7-1200
S7-1200 可编程控制器
产品样本 10.2015
使用 TIA 博途 软件平台进行 工程组态
/s7-1200
2
S7-1200 可编程控制器
产品样本 • 10.2015
技术综述
通信 CM 1241 通信模块 CSM 1277 紧凑型交换机模块 CM 1243-5 PROFIBUS DP 主站模块 CM 1242-5 PROFIBUS DP 从站模块 CP 1242-7 GPRS 模块 TS 模块 CM 1278 I/O 主站模块
W 90 mm 110 mm 130 mm 150mm 45 mm
70 mm 30 mm
H 100 mm 100 mm 100 mm 100mm 100 mm
100 mm 100 mm
D 75 mm 75 mm 75 mm 75mm 75 mm
75 mm 75 mm
西门子(Siemens)建筑技术产品,室温传感器系列1000和标准设计半沉入型系列2000(互动)说

Technical Specification SheetDocument No. 149-312P25February 20, 2018 Room Temperature Sensors, Series 1000 and Standard Design and Semi-Flush MountSeries 2000 (Interactive)Figure 1. Room Temperature Sensor--Series 1000 Shown withAll Available Options.The Series 1000 and Series 2000 Room TemperatureSensors from Siemens Building Technologies, Inc.,offer a wide range of features and functionality thatwork in concert with the APOGEEâ AutomationSystem to deliver exceptional occupant comfort ineven the most demanding application environments.The product family includes plain sensing-onlyvariants, and fully interactive types with a two-line LCDthat permits viewing and modifying controller pointsdirectly from the sensor’s keypad and display as wellas a semi-flush mount model (Series 2000). Allsensors incorporate precision temperature sensingelements to accurately and reliably measure roomtemperature. Their compact, low profile design resultsin an attractive, inconspicuous installation. A styledventilation ring optimizes airflow through the cover forfast measurement response and superior control.Series 1000The Series 1000 Room Temperature Sensor providesaccurate, reliable sensing of room temperatureTerminal Equipment Controllers (TECs), ModularBuilding Controllers (MBCs), Remote BuildingControllers (RBCs), Programmable ModularControllers (PXCs) and Modular Equipment Controllers(MECs).TEC ApplicationsRoom temperature sensors for TEC applicationsincorporate a thermistor element and plug-in PortableOperator's Terminal port located on the bottom of thecover. The plug-in Portable Operator's Terminal portprovides a convenient means of communicating withthe TEC to command or troubleshoot the system.These sensors connect to TECs via a six-wire cableterminated with a plug-in RJ-11 connector. The cabletransmits the temperature, the communication with thePortable Operator's Terminal, and the optional setpointand override signals.MBC, RBC, PXC, and MEC ApplicationsRoom temperature sensors for MBC, RBC, PXC andMEC applications incorporate a platinum RTDelement. Connections to field panels are made via 18to 22 AWG twisted pair cabling. A conveniently locatedunpluggable termination block simplifies bothinstallation and service.Optional Features·Digital temperature display: The digitaltemperature display provides an easy-to-readroom temperature value in degrees Fahrenheit orCelsius.·Setpoint adjustment: The high accuracy setpoint adjustment incorporates dual temperature scaleindication and an access door that covers thesetpoint adjustment switch.·Override button: The flush mounted override button allows an occupant to change to anoccupied control schedule during the unoccupiedcycle for a predetermined time period.·Maintenance free: These sensors draw a small amount of power directly from the controller anddo not use batteries. This eliminates the cost ofbattery replacement and disposal. Specifications (Series 1000)Temperature RangeSetpoint55°F to 95°F(13°C to 35°C)Operating55°F to 95°F(13°C to 35°C)Output Signals Changing resistanceSensing Element Type540 Models 10K NTC Thermistor (Type II)544 Models 1K Platinum RTD (375 ALPHA)Accuracy10K ohm Thermistor55 - 80.6°F (13 - 27°C)C)±0.5°F (±0.3°C)80.6 - 95°F (27 - 35°C)C)±1.0°F (±0.5°C)1,000 ohm RTD mid-range75°F (24°C)±1.3°F (± 0.72°C)Calibration Adjustments None requiredInstallationTEC100 ft. Maximum cable length.6C #24 AWG, Belden 1228A orequal, NEC Class 2MBC/RBC/PXC/MEC300 to 750 ftMax. cable length 18 to 22 AWGtwisted pair NEC Class 2 Installation Adjustments None requiredCoverDimensions3-11/32" H × 2-1/2" W × 1-1/2" D(85 mm × 63 mm × 38 mm) Color Desert beige or whitePower Consumption1544-7xx units8.6 mW maximum1 Power consumption values apply only to those units withsingle line display.Figure 2. Room Temperature Sensor and Semi-Flush Mount Room Temperature Sensor--Series 2000. Series 2000The Series 2000 Room Temperature Sensors provide an interactive digital link to Terminal Equipment Controllers (TECs) that allows viewing and adjusting controller points directly from the sensor’s liquid crystal display and keypad. These sensors incorporate a precision thermistor to accurately and reliably measure room temperature.NOTE:The Semi-Flush Mount Sensor can onlybe mounted in a 2 × 4 box without a gangriser/ring.Standard Features·Programmable Liquid Crystal Display (LCD): A two-line alphanumeric LCD allows simultaneousdisplay of room temperature, a user-selectedcritical point, and day/night operation status. Youcan configure the screen to:-show English or metric units,-turn the room temperature display on or off,-select a critical point for display, or-turn off the critical point display.·Digital setpoint adjustment: The sensor’s keypad allows error-free digital setpoint adjustments inone-degree increments. Setpoint valuesmomentarily display as changes are made.·Display of operating mode: Graphic symbols are displayed to indicate the controller’s operatingmode. A “sun” indicates occupied mode operation and a “moon” indicates night mode operation.·Override button: A flush-mounted override button allows you to change to an occupied controlschedule during the unoccupied cycle for a period of time determined by the system operator.Siemens Industry, Inc.Page 3 of 4Standard Features, Continued· Passkey security: A special hardware passkeyplugs into the sensor’s MMI port to allow access to the display configuration menu and the controller’s point database.NOTE:The Semi-Flush Mount Sensor MMI portcan only be accessed after the front housing is removed.- Backward compatibility: These sensors arebackward compatible with all TECs. The sensors are wired with six-conductor phone cables and standard RJ-11 connectors.- Maintenance free: These sensors draw asmall amount of power directly from the controller and do not use batteries. This eliminates the cost of battery replacement and disposal.Specifications (Series 2000)Effective Sensing and Setpoint Range (TEC)55°F to 95°F (13°C to 35°C)Output Signals Changing resistance Room temperature Changing resistance Setpoint Digital Thermistor Calibration Point (TEC)77°F (25°C)Accuracy (10K ohm Thermistor) 55 - 80.6°F (13 - 27°C)±0.5°F (±0.3°C) 80.6 - 95°F (27 - 35°C)±1.0°F (±0.55°C)Accuracy (QAA1280.FWSC) 60°F - 85°F (140°C - 185°C)+3°F (1.7°C) Other temperature ranges+4°F (2.2°C) Resistance value 10K W ohms Calibration None required Installation (TEC)100 ft maximum cable length 6C#24 AWG, NEC Class 2Installation Adjustments None required Dimensions 3-11/32" H × 2-1/2" W × 1-1/2" D(85 mm × 63 mm × 38 mm)Color Desert beige or whiteProduct Ordering InformationTEC Description Product Part NumberSeries 1000Sensing only540-6601Sensing only, no logo. White 540-661BSensing with override and setpoint 540-6701Sensing with override and setpoint, no logo540-6711Sensing with override, setpoint and temperature display 540-6802Series 2000TEC Sensor540-6501Semi-Flush Mount Room Temperature Sensor, TEC QAA1280.FWSCMBC/RBC/PXC/MEC, Series 1000 Description Product Part NumberSensing only544-7601Sensing with override, setpoint544-7701Sensing with override, setpoint, temperature display 544-78021Add letter suffix to indicate desired color: A=Desert Beige, B=White (for example, 540-660A).2Add letter suffix to indicate temperature display units and color: F=°F, C=°C, A=Desert Beige, B=White (for example,540-680FA).Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes asdesign improvements are introduced. APOGEE is a registered trademark of Siemens Industry, Inc. Other product or company names mentioned herein may be the trademarks of their respective owners. © 2018 Industry, Inc.Siemens Industry, Inc .Building Technologies Division 1000 Deerfield ParkwayBuffalo Grove, IL 60089-4513USA+1-847-215-1000Your feedback is important to us. If you have comments about this document, please send them to***************************************Document No. 149-312P25Printed in the USAPage 4 of 4Accessories Ordering InformationDescriptionProduct Part Number Occupancy Override Button, 25-pack (Beige)544-480A Occupancy Override Button, 25-pack (White)544-480B Setpoint Door, 25-pack (Beige)544-481A Setpoint Door, 25-pack (White)544-481B Blank Bezel, 25-pack (Beige)544-482A Blank Bezel, 25-pack (White)544-482B Room Temperature Sensor Repair Kit, Single-pack (Beige)544-483A Room Temperature Sensor Repair Kit, Single-pack (White)544-483B Blanking Override Button, 25-pack (Beige)544-484A Blanking Override Button, 25-pack (White)544-484B Passkey for Series 2000 Room Temperature Sensors 544-643A Single Adapter Base Kit (White)544-782B Single Adapter Base Kit (Beige)544-782A Double Adapter Base Kit (White)544-783B Double Adapter Base Kit (Beige)544-783A Extender Ring Kit (White)544-785B Extender Ring Kit (Beige)544-785A Non-Conduit Rough-In Kit544-784Series 2000 (Interactive) Room Temperature Sensors, User Guide129-363Sensor Power Supply Module (for MBC applications with digital display option) PTX6.4SPSAvailable with vinyl or plenum jacket in 25-foot, 50-foot and 100-foot lengths.Contact your local Siemens Industry, Inc. field office for more information.TEC room sensor cables (6 conductor w/RJ-11connectors on each end)DisposalThe devices are considered electrical and electronic equipment for disposal in terms of the applicable European Directive and may not be disposed of as domestic garbage.· Dispose of the devices through channels provided for this purpose.·Comply with all local and currently applicable laws andregulations.。
S7-1200选型手册

笙罄合音,无限创新SIMATIC S7-1200 引领小型自动化系统的未来SIMATIC 控制器Answers for industry.2模块化设计、功能强大、易于使用完美的整合在我们新推出的面向简单而高精确度自动化任务的产品中,核心组件是新型的模块化 SIMATIC S7-1200 控制器。
SIMATIC HMI 精简系列面板能够无缝兼容该控制器和功能强大的集成工程组态系统,其性能经过优化,确保了简化开发、快速启动、精确监控并具有高可用性。
上述产品的完美整合,以及其所具有的创新特点,为小型自动化系统带来前所未有的高效率。
控制器SIMATIC S7-1200 控制器具有模块化、结构紧凑、功能全面等特点,适用于多种应用,能够保障现有投资的长期安全。
由于该控制器具有可扩展的灵活设计,符合工业通讯最高标准的通讯接口,以及全面的集成工艺功能,因此它可以作为一个组件集成在完整的综合自动化解决方案中。
通用的接口、强大的通讯功能以及简单且与众不同的集成工程组态软件带给您全新的应用感受。
SIMATIC S7-1200 和 SIMATIC HMI 精简面板完美的应用集成以及 STEP 7 Basic 工程组态软件为您提供了全新整合的小型自动化解决方案。
整合整合的意义222414186810121620控制器面板软件控制器的详细信息– 可扩展的灵活设计– 工业通讯– 集成工艺面板的详细信息软件的详细信息在自动化领域中,功能强大的组件是取得成功的关键因素。
然而要想获得独特的优势,必须依靠组件之间的协作。
面板对小型机器或简单应用的操作可以通过可视化得到进一步的改善。
SIMATIC HMI 精简系列面板具有最基本的功能,为实现创新的自动化解决方案提供了一种经济可行的选择。
SIMATIC HMI 精简系列面板包括高对比度的图形显示屏(触摸和功能键操作),其简单组网和无缝通讯的特点使其成为了适用于 SIMATIC S7-1200 应用的理想面板。
消弧产品规格标准化规定

41
27
DKSC-500-250/10
10.5
41
28
DKSC-550-100/10
10.5
75
29
DKSC-550-250/10
10.5
52
30
DKSC-600-100/10
10.5
82
31
DKSC-600-400/10
10.5
33
32
DKSC-630-100/10
10.5
90
33
DKSC-630-160/10
消弧产品规格标准化规定
干式调匝消弧线圈
表1干式调匝消弧线圈规格参数表
电压
序号
产品型号
额定电压(kV)
等比/等差
档位
电流范围
6kV
1
XHDCZ-100/6
6.3/√3
等比
11
7~28A
2
XHDCZ-175/6
6.3/√3
等比
11
10~50A
3
XHDCZ-200/6
6.3/√3
等比
15
10~55A
4
XHDCZ-250/6
10.5
105
41
DKSC-800-315/10
10.5
82
42
DKSC-800-400/10
10.5
66
43
DKSC-850-100/10
10.5
125
44
DKSC-900-100/10
10.5
132
45
DKSC-900-400/10
10.5
82
46
DKSC-1000-100/10
IGBT模块型号参数大全

各品牌IGBT模块型号参数大全
一.IGBT模块
1.富士IGBT N系列(高速,低导通压降) P系列 S系列
2.EUPEC(西门子)IGBT 电流参数据库85C标称
DN2:标准系列
KE3:低导通压降系列
KS4:高速系列
DLC:低导通压降系列
PIM:三相桥+七单元+NTC GP系列 FP系列
大功率IGBT模块
CHOPPER=IGBT+二极管 GAL=IGBT+C接二级管 GAR=IGBT+E接二极管
3.三菱IGBT模块
H系列
H系列
A系列
NF系列
U系列
MDX系列
MD3:单相桥+六单元 MD1:三相桥+六单元 MD:三相桥+七单元
E3系列
4.SEMIKRON(西门康)IGBT
低损耗型(频率:0-4KHZ)
沟道式超低损耗型(频率0-6KHZ)
标准系列(频率:4-12KHZ)
软穿通式高速型(频率:5-20KHZ)
CHOPPER GAL=IGBT+C串二极管 GAR=IGBT+E串二极管
MiniSKiiP系列
SEMIX系列
SEMITOP系列
GAL=IGBT+C串二极管 GAR=IGBT+E串二极管
SKIM系列
超高速型(频率:30KHZ)
大功率集成装置(SEMISTACK)
5.IXYS(艾赛斯)IGBT
ID=IGBT+C串二极管 DI=IGBT+串二极管
6.APT IGBT
7.DYNEX IGBT
8.ABB IGCT
模块的基本参数,IGBT模块中文资料参数.。
3COM 1200 1201用户手册.pdf说明书

USER MANUALMODEL 1200/1201SynchronousModem EliminatorSALES OFFICE (301) 975-1000TECHNICAL SUPPORT P/N: 07M1200-CDoc# 049011U,Rev. DRevised 1/22/081.0Warranty Information (5)1.1Warranty Statement (5)1.2Radio and TV Interference (5)1.3CE Notice (6)1.4Service (6)2.0General Information (7)2.1Features (7)2.2Description (7)3.0Installation (8)4.0Configuration (9)4.1Data Rate (9)4.2Carrier Detect (9)4.3RTS/CTS Delay (10)4.4Ground (10)5.0Operation (11)5.1LED Status Indicators (Model 1201 only) (11)A Specifications (12)A.1Data Rates (12)A.2Clocking (12)A.3Grounding (12)A.4Range (12)A.5Functional (12)A.6RTS/CTS Delay (12)A.7DCD (12)A.8Ring Indicator (12)A.9Interface (12)A.10Connectors (12)A.11Power Supply (12)A.12Altitude (12)A.13Humidity (12)A.14Dimensions (12)B Block Diagram (13)1.0 WARRANTY INFORMATIONPatton Electronics warrants all Model 1200/1201 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.1.1 WARRANTY STATEMENTPatton Electronics warrants all Model 2701RC Series components to be free from defects, and will—at our option—repair or replace the prod-uct should it fail within one year from the first date of shipment. This war-ranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse, or unauthorized modification. This prod-uct contains no serviceable parts; therefore the user shall not attempt to modify the unit in any way. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other war-ranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user. In the event the user detects intermittent or continuous product malfunction due to nearby high power transmitting radio frequency equipment, the user is strongly advised to use only data cables with an external outer shield bonded to a metal or metalized connector.1.2 RADIO AND TV INTERFERENCEThe Model 1200/1201 generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the man-ufacturer’s instructions-may cause interference to radio and television reception. The Model 1200/1201 has been tested and found to comply with the limits for a Class A computing device in accordance with specifi-cations in Subpart B of Part 15 of FCC rules, which are designed to pro-vide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1200/1201 does cause interference to radio or television reception, which can be determined by disconnecting the unit , the user is encouraged to try to correct the inter-ference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).1.3 CE NOTICEThe CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Cer-tificate of Compliance is available by contacting Technical Support.This device is not intended to be connected to the publictelephone network.Caution1.4 SERVICEAll warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi-als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics T echnical Services at:•Tel: +1(301) 975-1007•Email: ******************•URL: Note Packages received without an RMA number will not beaccepted.2.0 GENERAL INFORMATIONThank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Y ear parts and labor. If any questions or problems arise during installation or use of this product, please contact Patton Electronics Customer Service at (301) 975-1007.2.1 FEATURES•Smallest synchronous modem eliminator available•Data rates to 38.4 Kbps•Synchronous cable runs to 300 feet on each side of device •Constant or RTS controlled carrier selections•RTS-CTS delay options of 0mS, 6.6mS or 53mS•DB-25 connector on each end•Half or full duplex•Internal or external clocking•No external power required•LEDs monitor data and control signals (Model 1201 only)2.2 DESCRIPTIONMeasuring only 5.3 x 2 x 1.2 inches, the Patton Model 1200 is the small-est self-powered synchronous modem eliminator on the market. All power is derived from the RS-232 data signals, so no AC power or bat-teries are required. Constructed with a DB-25 connector on each end, the Model 1200 can extend synchronous cable runs to 300 feet on each side of the device. Optimum distance is achieved at 9600 bps, and strap selectable data rates may extend up to 38,400 bps.The Model 1200 provides internal or external clock options and operates half or full duplex. To emulate dial-up or dedicated service, the delay between RTS and CTS can be set to either 0mS, 6.6mS or 53mS. The carrier can be configured either as “constantly on” or “controlled by RTS”. The Model 1201 has all the features of the Model 1200, plus LED indica-tors that monitor receive data, request to send and data carrier detect on each side of the device.Do the following to install the Patton Model 1200:1.Configure according to the instructions listed in section 4.0, “Config-uration” on page 7.2.Turn off the computer or device to which the Model 1200 is to beconnected.3.Plug the DB-25 connectors directly into the serial ports of your RS-232 devices. If you wish to extend the distance, you can add cableson both sides (see Figure 1).Note Cables must not be longer than 300 feet (see Figure 1).Figure 1.ConfigurationThe Model 1200 is equipped with four strapping options that allow config-uration to a wide range of applications. To gain access to the internal straps, loosen the hex nuts on the DB-25 connectors and pry open the case between the plastic shell ears. Figure 2 shows the location of each strapping option.Figure 2. Strap settings for the Model 1200/12014.1 DATA RATEThe data rate strap controls the rate at which data is transmitted. Adjust the strap to select one of the following options: 1.2, 2.4, 4.8, 9.6, 19.2, 38.4 or external clocking. If “external clocking” is selected, the Model 1200 will automatically match the clocking between your two synchro-nous devices. The default setting is 9.6 Kbps.4.2 CARRIER DETECTThe carrier detect straps allow you to determine whether the carrier is “constantly on” or “controlled by RTS”. By adjusting the strap, you may operate in switched carrier, multi-point and/or hardware handshaking applications. Port 1 and port 2 may be configured separately. The defaults setting is “on” for both ports.4.3 RTS/CTS DELAYThe RTS/CTS delay straps determine the amount of delay between the time the Model 1200 “sees” RTS and when it sends CTS. In order to emulate either dial-up or leased line modems, you can set this strap at either no delay, 6.6mS or 53mS. Port 1 and port 2 may be configured separately. The default setting is 6.6mS for both ports.4.4 GROUNDThe ground strap setting connects the protective ground from port 1 or 2 to the Model 1200’s signal ground. The default setting is port 1.5.0 OPERATIONOnce you have configured the Model 1200 properly (see section 4.0, “Configuration” on page 7) and plugged it into your equipment, you are ready to operate the unit. After the Model 1200 is properly installed, it should operate transparently—as if it were a standard cable connection. Operating power is derived from the RS-232 data and control signals; there is no “ON/OFF” switch.5.1 LED STATUS INDICATORS (MODEL 1201 ONLY)The Model 1201 features six front panel status LEDs that indicate the condition of the modem eliminator and the communication link. The dia-gram below shows the location of each of these LEDs. Following the dia-gram is a description of each LED’s function.•“TD” and “RTS” indicators blink with data activity.•“CD” lights for an incoming signal on the line side and the resulting out-put signal on the RS-232.APPENDIX ASPECIFICATIONSA.1 DATA RATESSelectable: 1200, 2400, 4800, 9600, 19200, 38400A.2 CLOCKINGInternal or externalA.3 GROUNDINGProtective ground (pin 1) may be strapped to signal ground (pin 7)A.4 RANGE300 feet on either side (for a total of 600 feet) at 9600 bps, range extends linearly for lower bit rates and decreases for higher bit ratesA.5 FUNCTIONALEmulates half or full duplex, dial-up or dedicated lineA.6 RTS/CTS DELAYSelectable per port: 0mS, 6.6mS, 53mSA.7 DCDSelectable per port: continuous or RTS controlledA.8 RING INDICATORConstantly onA.9 INTERFACEEIA RS-232C/CCITT V.24A.10 CONNECTORSChoice of two male or two female DB-25 RS-232 connectorsA.11 POWER SUPPLYNone requiredA.12 ALTITUDE0 to 10,000 feetA.13 HUMIDITYUp to 95% non-condensingA.14 DIMENSIONSApproximately 5.3 x 2 x 1.2 in.APPENDIX BBLOCK DIAGRAMCopyright © 2001 Patton Electronics Company All Rights Reserved.Dear Valued Customer,Thank you for purchasing Patton Electronics products! We do appreci-ate your business. I trust that you find this user manual helpful.We manufacture one of the widest selections of data communications products in the world including CSU/DSU's, network termination units, powered and self-powered short range modems, fiber optic modems, interface converters, baluns, electronic data switches, data-line surge protectors, multiplexers, transceivers, hubs, print servers and much more. We produce these products at our Gaithersburg, MD, USA, facility, and can custom manufacture products for your unique needs.We would like to hear from you. Please contact us in any of the following ways to tell us how you like this product and how we can meet your prod-uct needs today and in the future.Web: Sales E-mail: ****************SupportE-mail:******************Phone - Sales (301) 975-1000Phone - Support (301) 975-1007Fax: (301) 869-9293Mail: Patton Electronics Company7622 Rickenbacker DriveGaithersburg, MD 20879 USAWe are committed to a quality product at a quality price. Patton Electron-ics is ISO 9001 certified. We meet and exceed the highest standards in the industry (CE, UL, etc.).It is our business to serve you. If you are not satisfied with any aspect of this product or service provided by Patton Electronics or its distributors, please let us know.Thank you.Burton A.PattonVice PresidentP.S. Please tell us where you purchased this product.________________________________________________________ ________________________________________________________ ________________________________________________________。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
ແ͠
Without
neutral
্෦
detent
1
2
ઃఆܕ
Top setting ༗Γ
With
neutral
detent
แܗଶ Form of packaging
ςʔϐϯά Taping
ϙϦା Plastic bag
ςʔϐϯά Taping
ϙϦା Plastic bag
ચড়ʢςʔϓγʔϧ༗Γʣ
Approx. 0.05g (CJS-1200) Approx. 0.06g (CJS-1201)
˙ిؾతಛੑ
ELECTRICAL CHARACTERISTICS
ఆ֨ Contact rating
Non-switching Switching Minimum
৮߅ Contact resistance
CJS
SLIDE SWITCHES (SMD)
˙֎ੇܗ๏ਤɹOUTLINE DIMENSIONS
Unless otherwise specified, tolerance : ± 0.3 (Unit : mm)
● CJS-1200A1
● CJS-1200B1
3
–
0.6
+0.1 –0.05
݄߸ه
C
Production date code
ᶄ
3
–
0.6
+0.1 –0.05
ε
݄߸ه
C
Production date code
ᶄ
Π ỽ
ν
Terminal No.1
2 – C 0.5
ᶃᶅ Schematic
Terminal No.1
2 – C 0.5
245 ± 3 °C, 2 ~ 3 s ϦϑϩʔɹReflowɿ255 °C (Peak temperature) ʢৄࡉԼهϓϩϑΝΠϧࢀরɹPlease refer to the profile belowʣ खΜͩ Manual solderingɿ350 ± 10 °C, 3 ~ 4 s
90 ± 30 s 30 ± 10 s
Heating time Soldering Zone
Ϧϑϩʔճɿ̎ճɹReflow : two times maximum
A-58 http䂓://o᭽ne䈲icᡷ.cༀom䈱/䈢䉄ᄌᦝ䈘䉏䉎႐ว䈏䈅䉍䉁䈜䇯㩷㩷㩷㪪㫇㪼㪺㫀㪽㫀㪺㪸㫋㫀㫆㫅㫊㩷㪸㫉㪼㩷㫊㫌㪹㫁㪼㪺㫋㩷㫋㫆㩷㪺㪿㪸㫅㪾㪼㩷㫎㫀㫋㪿㫆㫌㫋㩷㫅㫆㫋㫀㪺㪼㪅
—
˙ࣜܕදࣔɹPART NUMBER DESIGNATION
CJS-1201TB1
γϦʔζ໊ɹSeries name ճ࿏ɹNo. of poles ɿճ࿏ 41%5
1 pole
ɹNo. of contacts ɿɹ2 contacts
ઃఆํɹSetting position ɿ্෦ઃఆܕɹTop setting
ແચড়ʢςʔϓγʔϧແ͠ʣ
ແચড়ʢςʔϓγʔϧ༗Γʣ
ճ࿏ ઃఆํ தཱ No. of No. of Setting Neutral poles contacts position detent
แܗଶ Form of packaging
Non-washable type (Without seal tape) Non-washable type (With seal tape) แྔ
แܗଶɹForm of packaging
TɿςʔϐϯάʢϦʔϧʣ Taping (Reel)
ۭཝɿϙϦା
Bulk in plastic bag
Blank
˞͝จʹࡍͯ͠ɺࣜܕҰཡදΛ֬͝ೝ͍ͩ͘͞ɻ Please refer to the LIST OF PART NUMBERS when placing orders.
˙ػցతಛੑ
MECHANICAL CHARACTERISTICS
࡞ಈྗ Operating force
ૢ࡞෦ڧ Stop strength
Μ͚ͩੑ Solderability
Μͩੑ Soldering heat
5.9 N {0.6 kgf} maximum
10 N {1.02 kgf}, 60 s
தཱɹNeutral detent ɿແɹWithout neutral detent ɿ༗ɹWith neutral detent
SPDT : Single Pole Double Throw
ߏɹStructure
1ɿແચড়ʢςʔϓγʔϧແ͠ʣ جຊࣜܕ Non-washable type (Without seal tape) Standard type
ݻணੑ Shear (Adhesion)
ج൘͛ۂੑ Substrate bending
Ҿ͖͕͠͞ڧ Pull-off strength
5 N {0.51 kgf} 10 s Width 90 mm, bend 3 mm, 5 s, 1 time
5 N {0.51 kgf} 10 s { } : ࢀߟɹReference only
೩মੑ Flammability
114ʢϙϦϑΣχϨϯαϧϑΝΠυʣ Polyphenylenesulphide
1"ʢϙϦΞϛυʣ Polyamide
UL-94V-0
114ʢϙϦϑΣχϨϯαϧϑΝΠυʣ Polyphenylenesulphide
ಔ߹ۚɺۚΊ͖ͬ Copper alloy, Gold-plated
CJS-1201TB2 1000pcs./reel
neutral detent
ϙϦା Plastic bag
CJS-1201A1
CJS-1201B1
CJS-1201A2
CJS-1201B2 100pcs./pack
ճ࿏ ઃఆํ தཱ No. of No. of Setting Neutral poles contacts position detent
● RoHS compliant ● Easy to set slider with line marking ● With neutral detent type lined up to 1 pole 2contacts
switch ● Compatible with most automatic pick & place machinery ● Compact and space saving SMD type
Humidity
24 h for 10 cycles
ੑ High temp. exposure
85 °C, 96 h
פੑ Low temp. exposure
−40 °C, 96 h
ԹαΠΫϧ Thermal shock
− 40 (0.5 h) ~ 85 °C (0.5 h), 5 cycles
͞Βʹݟ͘͢ɺѻ͍͘͢ͳΓ·ͨ͠
δϟϯύεΠον SLIDE SWITCHES (SMD)
CJS
3P)4ࢦྩରԠɹRoHS compliant
ε Π ỽ ν
˙ಛɹɹFEATURES
● 3P)4ࢦྩରԠ ● ΧόʔͷϥΠϯϚʔΩϯάʹΑΓεϥΠμઃఆ͕༰қ ● ̍ճ࿏̎λΠϓʹதཱ༗ʢ0''ϙδγϣϯʣϥΠϯφοϓ ● ࣗಈࡌରԠ ● ද໘࣮ԽʹΑΓখܕɺলεϖʔεΛ࣮ݱ
CJS-1201TA CJS-1201TB 1000pcs./reel
CJS-1201A
CJS-1201B 100pcs./pack
˞͝จʹࡍͯ͠ɺ্ࣜܕهΛ֬͝ೝ͍ͩ͘͞ɻ ςʔϐϯά༷ɺΓചΓக͠·ͤΜͷͰɺϦʔϧ୯ҐͰ͝จΛ ͓͍ئக͠·͢ɻ
˞ Verify the above part numbers when placing orders. Taping version can be supplied only in reel unit.
2ɿແચড়ʢςʔϓγʔϧ༗Γʣ Non-washable typபைடு நூலகம் (With seal tape)
ۭཝɿચড়ʢςʔϓγʔϧ༗Γʣ Blank : Washable type (With seal tape)
ࢠܗঢ়ɹShape of terminal
AɿJ-Ϧʔυ BɿΨϧɾΟϯά
J-hook Gull wing
্෦
neutral detent
ϙϦା Plastic bag
CJS-1200A1
CJS-1200B1
CJS-1200A2
CJS-1200B2 100pcs./pack
1
2
ઃఆܕ
Top setting ༗Γ With
ςʔϐϯά Taping
CJS-1201TA1
CJS-1201TB1
CJS-1201TA2
෦ߏਤɹINTERNAL STRUCTURE
ᶃ ᶄ
ᶇ
ᶅ
ᶈ ᶆ
໊ɹশ Part name
ᶃ
Χόʔ Cover
ᶄ
εϥΠμ Slider
ᶅ
ϋδϯά Housing
ᶆ
Մಈ Slider contact
ᶇ
ݻఆ Fixed contact
ᶈ
ࢠ Terminal pin
ࡐɹྉ Material
A-57 http䂓://o᭽ne䈲icᡷ.cༀom䈱/䈢䉄ᄌᦝ䈘䉏䉎႐ว䈏䈅䉍䉁䈜䇯㩷㩷㩷㪪㫇㪼㪺㫀㪽㫀㪺㪸㫋㫀㫆㫅㫊㩷㪸㫉㪼㩷㫊㫌㪹㫁㪼㪺㫋㩷㫋㫆㩷㪺㪿㪸㫅㪾㪼㩷㫎㫀㫋㪿㫆㫌㫋㩷㫅㫆㫋㫀㪺㪼㪅