川大《电力系统分析基础(1)1350》19秋在线作业1答案

合集下载

电力系统分析基础部分习题答案

电力系统分析基础部分习题答案

电力系统分析部分习题答案(参考)稳态部分第一章 电力系统的基本概念1-2 (1)各个元件的额定电压 G :10.5kVT :10.5/121kV ,10.5kV/399V , 110/38.5/11(10.5)kV,35/6.6(6.3)kV (2) a)发电机和变压器的额定电压G:10.5kV T 1:10.5/121kV T 2:10.5/38.5kV T 3:35/11(10.5)kV b)变压器的实际变比T-1:121(1+2.5%)/10.5 T-2:110/38.5 T3:35(1-5%)/11(10.5)(3) G:10.5kV T 1:10.5/242kV T 2:220/121/38.5kV T 3:35/6.3kV T 4:220/38.5kV T 5:10.5/3.15kV D 1:3kV D 2:6kV第二章 电力网络元件的参数和等值电路2-2-1解:R T =P k *U N 2/(1000S N 2)=100*1102/(1000*31.52)=2.4389(Ω) X T =U k %*U N 2/(100S N )=10.5*1102/(100*31.5)=40.33(Ω) G T =P 0/(1000U N 2)=86/(1000*1102)=7.1074*10-6(s)B T =I 0%*S N /(100U N 2)=2.7*31.5/(100*1102)=7.0289*10-5(s) 等值电路为:2-2-3 解:R T(100)=P kmax *U N 2/(2000S N 2)=163*1102/(2000*202)=2.4654(Ω) R T(50)= 2R T(100) =2*2.4654=4.9307(Ω)U K1%=1/2*( U K1-2%+ U K1-3%- U K2-3%)=1/2*(10.5+17-6)=10.75 U K2%=1/2*( U K1-2%+ U K2-3%- U K1-3%)=1/2*(10.5+6-17)=-0.25 U K3%=1/2*( U K1-3%+ U K2-3%- U K1-2%)=1/2*(17+6-10.5)=6.25 X T1=U k1%*U N 2/(100S N )=10.75*1102/(100*20)=65.0375(Ω)X T2=U k2%*U N 2/(100S N )=-0.25*1102/(100*20)=-1.5125(Ω) X T3=U k3%*U N 2/(100S N )=6.25*1102/(100*20)=37.8135(Ω)G T =P 0/(1000U N 2)=75/(1000*1102)=6.1983*10-6(s)B T =I 0%*S N /(100U N 2)=3.3*20/(100*1102)=5.4545*10-5(s)2-2-5解:P k13=4P ’k13=4*52=208kW P k23=4P ’k23=4*47=188kW P k1= (P k12+P k13- P k23)/2=(152.8+208-188)/2=86.4kW P k2= (P k12+P k23- P k13)/2=(152.8+188-208)/2=66.4kW P k3= (P k23+P k13- P k12)/2=(188+208-152.8)/2=121.6kW R T1=P k1*U N 2/(1000S N 2)=86.4*1212/(1000*202)=3.16(Ω) R T2=P k2*U N 2/(1000S N 2)=66.4*1212/(1000*202)=2.43(Ω) R T3=P k3*U N 2/(1000S N 2)=121.6*1212/(1000*202)=4.45(Ω) U K1%=1/2*( U K1-2%+ U K1-3%- U K2-3%)=1/2*(10.5+18-6.5)=11 U K2%=1/2*( U K1-2%+ U K2-3%- U K1-3%)=1/2*(10.5+6.5-18)=-0.5 U K3%=1/2*( U K1-3%+ U K2-3%- U K1-2%)=1/2*(18+6.5-10.5)=7 X T1=U k1%*U N 2/(100S N )=11*1212/(100*20)=80.53(Ω) X T2=U k2%*U N 2/(100S N )=-0.5*1212/(100*20)=-3.66(Ω) X T3=U k3%*U N 2/(100S N )=7*1212/(100*20)=51.24(Ω) G T =P 0/(1000U N 2)=75/(1000*1212)=5.123*10-6(s)B T =I 0%*S N /(100U N 2)=4.1*20/(100*1212)=5.60*10-5(s) 2-1-2 解:(a )ρ=31.5Ω.mm 2/kM S=150 mm 2 r1=ρ/S=0.21Ω/kM D m =68mm .50398*4*4D D D 33bc ac ab == r=17.0/2=8.5mmx1=0.1445lg(D m /r)+0.0157=0.4164Ω/kM b1=7.58/lg(D m /r)*10-6=2.7335*10-6s/kM (b)因为为双回输电线路R=r1*l/2=0.21*100/2=10.5(Ω) X=x1*l/2=0.4164*100/2=20.8198(Ω) B/2=2*b1*l/2=2*2.7335*10-6*100/2=2.734*10-4 (S) (c) Q=U 2*B=1102*2.734*10-4*2=2*3.308=6.616Mvar 2-1-6解:因为为分裂导线r1=ρ/S=31.5/(2*300)=0.0525Ω/kMΩD m =0794m .1016*8*8D D D 33bc ac ab == 5691mm .70400*12.45d *r r 12eq ===x1=0.1445lg(D m /r eq )+0.0157/2=0.3192Ω/kM b1=7.58/lg(D m /r eq )*10-6=3.5177*10-6s/kM R=r1*l=0.0525*300=15.75(Ω) X=x1*l=0.3192*300=95.7665(Ω) B/2=b1*l/2=0.5277*10-3 (S) 2-4-1解:G :S N =P N /cos φN =50/0.85=58.8235MV AXd ”=0.15*10.52/58.8235*(242/10.5)2=149.3382(Ω) T: R T =P k *U N 2/(1000S N 2)=300*2422/(1000*602)=4.8803(Ω) X T =U k %*U N 2/(100S N )=12.5*2422/(100*60)=122.0083(Ω) G T =P 0/(1000U N 2)=90/(1000*2422)=1.5368*10-6(s) B T =I 0%*S N /(100U N 2)=2*60/(100*2422)=2.049*10-5(s)L :R=r1*l=0.08*200=16(Ω) X=x1*l=0.406*200=81.2(Ω)B/2=b1*l/2=2.81*10-6*200/2=2.81*10-4 (S) 2-4-3解:X 线路=x1*l=0.4*70=28(Ω)U B =110kV ,S B =20MV A,且变压器的变比为110/6.6kV ,所以: X T*=U k %/100*(U N 2/S N )/(U B 2/S B )=0.105 X T*/2=0.0525 X 线路*=28/(1102/20)=0.0463X R*=2121.020/6.6/3.0*3/6*04.0S U /I 3U *100%X 2B 26.B6NNR ==)()()( 因为为双回线X 电缆*=1/2*x1*l/(U B 2/S B )=1/2*0.08*2.5/(6.62/20)=0.0918/2=0.0459R 电缆*=1/2*ρ/S *l/(U B 2/S B )=1/2*18.8/70*2.5/(6.62/20)=0.3083/2=0.15415第三章 简单电力系统的分析和计算3-1-1解:首先求出线路的参数:D=6.5m D m =1895m .813*5.6*5.6D D D 33bc ac ab == 查表得单位线路参数:r1=0.079Ω/kM x1=0.412Ω/kM b1=2.77*10-6S/kM 线路的等值电路为π型等值电路R=r1*l=0.079*230=18.17Ω X=x1*l=94.76Ω B/2=3.1855*10-4S 进行潮流计算:P 2=120MW cos φ=0.92 ⇒Q 2=51.1198MVar线路末端的注入功率: Q 2l =1/2*U 22*B=3.1855*10-4*2092=13.9146MVar S 2’=S 2-Q 2l =120+j51.1198-j13.9146=120+j37.2052 MV A 线路阻抗支路的功率损耗:ΔS Z =(P 2’2+Q 2’2)/U 22*(R+jX)=6.5658+j34.2417 MV A S 1’=S 2’+ΔS Z =126.5658+j71.4469 MV A 求线路上的首端电压:173kV .j513.236U R Q X P j U X Q R P U U j U U U 2'2'22'2'222221+=-+++=+∆+=δ U 1=241.7788kV 线路首端注入电容功率:Q1l=1/2* U 12*B=18.6215Mvar线路首端功率:S 1=S 1’-Q1l=126.5658+j52.8255 MV A 3-1-2解:末端注入功率:Q 2l =1/2*U 22*B=5.5*10-4*2202=26.62Mvar 设末端功率因数为cos φ2,则有:S 2’=S 2-Q 2l =P 2+jQ 2-jQ 2l =220+j(Q 2-Q 2l )=220+j(Q2-26.62)=P 2’+jQ 2’2'2'22'2'222221U R Q X P j U X Q R P U U j U U U -+++=+∆+=δ 22'2'222'2'22222221)U R Q X P ()U X Q R P U ()U ()U (U U -+++=+∆+=δ解得Q 2’=95.2162,所以Q 2=121.8362Mvar 8748.0Q P /P cos 22222=+=ϕ 3-1-14解: 线路参数为:R=r1*l=0.82*2=1.64Ω X=x1*l=0.38*2=0.76Ω 忽略电压降落横分量有⎪⎪⎩⎪⎪⎨⎧⨯+≤⨯≤+%10*)R U )cos /(P P (R U )cos /(P U %10U X Q R P 22222222222N222ϕϕ 将R ,X, cos φ,U N 带入得561MW .1P 561MW .1P 629MW.1P 222≤⎩⎨⎧⇒≤≤ 当P 2=1.561MW 时,10%p%9.58%U U X Q R P %U N222=∆=+=∆3-1-15解:Ω=⇒⎪⎩⎪⎨⎧=====≤+ 1.5R 600kW P 3kV,U U ,X R ,0Q U %10U XQ R P 22N 2N222 342.86kW P 8.0cos ,X R U %10U X Q R P '2N 2'22'≤⇒⎪⎩⎪⎨⎧==≤+ϕ 3-1-17解1(a)首先求出系统的等值电路,计算各个元件的参数LGJ-185: D=4m , 0397m .52*4D 3m ==,查表得:r1=0.17Ω/kMx1=0.409Ω/kM b1=2.79*10-6S/kM因为为双回线,有:R=r1*l/2=100*0.17/2=8.5Ω, X=x1*l/2=0.409*100/2=40.9/2Ω B=2*b1*l=2*2.79*100*10-6=2*2.79*10-4S计算变压器的参数:查表得:P k =190kW,P 0=31.05kW,Uk%=10.5,I 0%=0.7 归算至高压侧的阻抗和导纳参数为:X T =40.3333Ω,R T =2.317Ω,G T =2.5661*10-6S ,B T =1.8223*10-5S 因为两台变压器并列运行,所以并列运行后的参数为X ’T = X T /2= 40.3333/2Ω,R T =2.317/2Ω,G T =2*2.5661*10-6S ,B T =2*1.8223*10-5S 又因为:P2=40MW, 8.0cos 2=ϕ,所以Q 2=30MVar 系统的等值电路为:变压器低压侧U 21=10.5kV ,归算到高压侧为U 2=k*U 21=110/11*10.5=105kV (1)j7.3515kV111.2032 j7.3515kV2032.6105U R Q X P j U X Q R P U U j U U U 2'T 2'T 22'T 2'T 222222'+=++=-+++=+∆+=δ U ’2=111.446kV变压器损耗:AyTmaxyTmax 'T 'T 2'2yT ZTmaxZTmax 'T 'T 222222ZT Q j P 4527MV A .j00637.0)jB G (U S ~Q j P j4.5729MV A 2627.0)jX R (U Q P S ~∆+∆=+=+=∆∆+∆=+=++=∆(或者用下式计算变压器的损耗441MVA.j00621.0)31.5*0.007*j 03105.0(*2)jQ P (2S ~j4.1667MVA0.239431.5)*10010.5j (0.19*)5.31*2(3040*2)jQ P ()2S S (2S ~yT yT yT 222kT kT 2N ZT +=+=+=∆+=++=+=∆)线路注入功率: 4652MV ar .3446.111*10*79.2U *B *2/1Q 242'22l -=-=-=- 所以5604MVA .j313264.40jQ S ~S ~S ~S ~2l yT ZT 2'1+=+∆+∆+=线路的首端电压j12.918kV119.72 j5.5667kV 5183.8UU RQ X P jU XQ R P U U j U U U 2'2'*'1'12'*'1'12'l l 2'1+=++=-+++=+∆+= δU 1=120.4165kV线路上的阻抗损耗和首端线路电容注入功率0455MVar.4120.4165*10*79.2U *B *2/1Q Q j P j4.3167MVA 7946.1)jX R (U Q P S ~2411l ZTm axZlm ax '22'21'21Zl -=-=-=∆+∆=+=++=∆-线路首端功率8325MVA .j3142.121jQ S ~S ~S ~1l Zl 1''1+=+∆+= (2)查表得3150max =τ121MW .27946.10637.02627.0P P P P yTmax Zlmax ZTmax Tmax =++=∆+∆+∆=∆全年总的电能损耗为:6824.5MW.h543.9965653.0827.5050 8760*0.06213150*1.79463150*0.2627 8760*P 3150*P 3150*P W yT Zlmax ZTmax =++=++=∆+∆+∆=∆2.当负荷变为原来的0.5倍和0.25倍时,变压器为单台变压器运行,线路仍为双回线运行,则等值电路为按上述过程计算得:当max 25P .0P =时4133MW .0P 0319.0P 1313.0P Zl yT ZT =∆=∆=∆,, 5765MW .0P 0.5pmax =∆ 当max 225P .0P =时0919MW .0P 03.0P 0328.0P Zl yT ZT =∆=∆=∆,, 1547MW .0P 0.25pmax =∆0MW.h.6975 6000-8760*P 20006000*P 2000*P W 0.25pmax 0.5plmax max =∆+-∆+∆=∆)()(3-2-3解:等值电路图从左向右编号分别为1,2,3,4,则有: 变压器2的功率损耗为:0021.j0(-j0.0162)*12.03.0Z U S S ~222T232N 2B23B23-=+==∆(第2个变压器的第3个绕组) 0066.j0j0.131*11.02.0Z U S S ~222TB222N 2B22B22=+==∆ 3045.j05.0Z U S S ~S ~S ~S ~S ~TB222N 2B22B23B22B22B23'B2+==∆+∆++=34222TB212N'2B2B2l S ~092.j0j0.268*13045.05.0Z U S S ~∆==+==∆ 则节点3的运算负荷为: j0.2780.5j0.118-j0.0923045.j05.0S ~S ~S ~S ~30B21'B23+=++=∆+∆+= 变压器1的功率损耗:016.j0j0.32*11.02.0Z U S S ~222TB12N 2B1Bl =+==∆j0.00510098.j0j0.156)(0.0298*1278.05.0Z U S S ~222232N2323+=++==∆ 129.j0j0.118)-(-j0.011*1Y U S ~20*2N 20-===∆316.j07098.0S ~S ~S ~S ~S ~S ~Bl Bl 202332+=+∆+∆+∆+=j0.00850016.j0j0.014)(0.026*1316.07098.0Z U S S ~222122N 2212+=++==∆3245.j07114.0S ~S ~S ~122A '+=∆+=011.j0(-j0.011)*1Y U S ~10*2N 10-===∆3135.j07114.0S ~S ~S ~S ~10122A +=∆+∆+=然后由以上计算所得的功率和已知的o A01.1U ∠= 计算各点的电压:(以下电压的计算也可以不考虑横分量)kV435.00943.1 j0.0083kV 0057.0U UR Q X P j UX Q R P U U j U U U o 1A12'A 12'A A12'A 12'A 1l2l212-∠=--=-++-=-∆-= δ同理可以计算kV 3.59062.1 j0.0583kV 0339.0U U j U U U o 2B1B12B1-∠=--=-∆-= δkV 3.99037.1 j0.0638kV 0601.0U U j U U U o 2232323-∠=--=-∆-= δ kV 11.69992.0 j0.129kV 1023.0U U j U U U o 3343434-∠=--=-∆-= δ kV 11.38994.0 j0.0048kV 0032.0U U j U U U o 4B3B34B3-∠=++=-∆-= δ kV 12.97012.1U j U U U o B2B24B2-∠=-∆-=δ 同理:然后算出各点的有名值kV 3.59887.40k *U *U U kV 435.075.240 U o B1N *B1B1o 2-∠==-∠= kV 3.9914.228U o 3-∠= kV 11.38586.68k *U *U U o B13N *B3B3-∠== kV 12.97626.10k *U *U U o B12N *B2B2-∠==3-2-6解:因为求初步功率分布,只需计算两端电源供给负荷的功率即可。

川大《电子技术基础(1)(上)1345》15秋在线作业1满分答案

川大《电子技术基础(1)(上)1345》15秋在线作业1满分答案

川大《电子技术基础(1)(上)1345》15秋在线作业1满分答案四川大学《电子技术基础(1)(上)1345》15秋在线作业1一、多选题(共 6 道试题,共 24 分。

)1. 三极管工作在放大区时,发射结和集电结分别处于( )。

A. 正偏B. 反偏C. 零偏正确答案:AB2. 差动放大电路()A. 能抑制零漂B. 提高输入电阻C. 减小输出电阻D. 增益与输入方式无关正确答案:AD3. 双极型三极管放大电路的组态有()A. 共射组态B. 共栅组态C. 共基组态D. 共源组态正确答案:AC4.A. m与j连接B. k与n 连接C. k与j连接D. m与n连接正确答案:AB5. 直流稳压电源包括下列哪些电路()A. 起振电路B. 选频网络C. 稳压电路D. 滤波电路正确答案:CD6. 在放大电路的三种组态中,共集电路()A. 电压放大倍数小于1B. 输入电阻最大C. 输出电阻最小D. 增益最大正确答案:ABC《电子技术基础(1)(上)1345》15秋在线作业1二、单选题(共 10 道试题,共 40 分。

)1. 当PN结外加正向电压时,耗尽层()A. 变宽B. 变窄C. 宽度不变2.A. 共射组态B. 共基组态C. 共集组态正确答案:A3. 在多级直流放大器中,零点漂移影响最严重的是()A. 输入级B. 中间级C. 输出级正确答案:A4.A. 0VB. -12VC. -15V5.A. 24VB. 18VC. 10V正确答案:A6. 1、硅二极管两端正向偏置电压大于多少时,二极管才能导通。

A. 0VB. 0.5VC. 0.7V正确答案:B7. 一个仪表放大电路,要求输入电阻大,并能稳定输出电压,应选()A. 电压串联负反馈B. 电流串联负反馈C. 电压并联负反馈8. 在三极管放大电路中,电压放大倍数小于1,但接近于1的是()A. 共发射极电路B. 共基极电路C. 共集电极电路正确答案:C9.A. 8KΩB. 6KΩC. 3KΩ正确答案:C10. 放大电路中,己知三极管三个电极的对地电位为VA=-6V、VB=-2.3V、VC =-2V , 则该三极管是()A. PNP锗管B. PNP硅管正确答案:A《电子技术基础(1)(上)1345》15秋在线作业1三、判断题(共 9 道试题,共 36 分。

四川大学网络教育《电力系统分析》答案汇编

四川大学网络教育《电力系统分析》答案汇编

分数: 100.0完成日期:2011年02月17日 23点26分说明:每道小题括号里的答案是学生的答案,选项旁的标识是标准答案。

一、单项选择题。

本大题共22个小题,每小题 2.0 分,共44.0分。

在每小题给出的选项中,只有一项是符合题目要求的。

1.发电机的额定电压与网络的额定电压为同一等级时,发电机的额定电压规定比网络的额定电压()( A )A.高5%B.高10%C.低5%D.低10%2.变压器一次绕组的作用相当于用电设备,其额定电压与网络的额定电压相等。

但直接与发电机联接时,其额定电压与发电机的额定电压相比()。

( D )A.高5%B.低5%C.低10%D.相等3.在()情况下,不适宜用调节变压器变比的方式升高电压,这样做有可能会引起系统其它节点电压下降。

( C )A.有功充足B.有功不足C.无功不足D.无功充足4.在发电机容量允许的情况下二次调整可以实现()。

( C )A.二次调整B.一次调整C.无差调节D.有差调节5.频率的一次调整不能实现()。

( B )A.二次调整B.一次调整C.无差调节D.有差调节6.采用逆调压方式的中枢点电压,在最大负荷时较线路的额定电压()。

( D )A.高2%~5%B.相等C.高2.5%D.高5%7.系统单位调节功率K表示在计及发电机组和负荷的调节效应时,引起频率单位变化的负荷变化量。

K的数值越(),负荷增减引起的频率变化就越(),频率也就越()。

()( C )A.小小稳定B.大大稳定C.大小稳定D.大小不稳定8.把中枢点电压保持在较线路额定电压高2%-5%的数值,不必随负荷变化来调整中枢点电压,这种调压方式称为()( C )A.逆调压B.顺调压C.常调压D.以上都不对9.( B )A. AB. BC. CD. D。

川大《发电厂电气部分(1)1349》19秋在线作业2答案

川大《发电厂电气部分(1)1349》19秋在线作业2答案
B.必须经济截面等于标准截面
C.必须经济截面小于标准截面
D.必须经济截面大于标准截面
答案:A
34.在下列设备选择与校验项目中,不适用于高压隔离开关的是()
A.额定电流
B.额定电压
C.额定开断电流
D.额定峰值耐受电流
答案:C
35.大中型发电厂,特别是火力发电厂的厂用电备用方式,常利用()
A.暗备用
B.明备用
7.少油式断路器中油的用途是()
A.隔离
B.绝缘
C.灭弧
D.冷却
答案:C
8.与导体长期发热的稳定温升有关的是()
A.载流量
B.起始温度
C.起始温升和载流量
D.起始温升
答案:A
9.矩形导体长边垂直布置与长边水平布置相比,额定载流量()
A.可大也可小
B.前者小于后者
C.前者大于后者
D.二者相等
答案:C
10.电流互感器正常运行时二次侧不允许()
C.快速启动的柴油发电机组
D.与系统相连的主变兼作备用
答案:B
二、多选题(共5道试题,共30分)
36.影响电流互感器运行误差的因素有()
A.二次侧负荷
B.一次侧负荷功率因数
C.一次侧电网频率
D.一次侧电流
E.一次侧电压
答案:AD
37.厂用供电电源包括()
A.照明电源
B.工作电源
C.备用启动电源
D.事故保安电源
A.都不允许
B.短路
C.接地
D.开路
答案:D
11.隔离开关的用途之一是()
A.拉合小电流回路
B.拉合大电流回路
C.切断负荷电流
D.切断短路电流
答案:A

川大《电力系统继电保护(1)1352》15秋在线作业2满分答案

川大《电力系统继电保护(1)1352》15秋在线作业2满分答案

四川大学《电力系统继电保护(1)1352》15秋在线作业2
一、单选题(共20 道试题,共40 分。


1. 在系统发生振荡时,距离III段保护不受振荡影响,其原因是( )。

A. 保护动作时限小于系统的振荡周期
B. 保护动作时限大于系统振荡周期
C. 保护动作时限等于系统的振荡周期
D. 以上都不对
———答案:B
2. 距离III段的灵敏度校验应按分支系数Kfz为最大的运行方式来确定,目的是为了保证保护的( )。

A. 速动性
B. 选择性
C. 灵敏性
D. 可靠性
———答案:C
3. 高频保护基本原理是———答案:将线路两端的电气量(电流方向或功率方向)转化为高频信号;以( )为载波传送通道实现高频信号的传送,完成对两端电气量的比较。

A. 微波通道
B. 光纤通道
C. 输电线路
D. 导引线
———答案:C
4. 在给方向阻抗继电器的电流、电压线圈接入电流电压时,一定要注意不要接错极性,如果接错极性,会发生方向阻抗继电器( )的后果。

A. 拒动
B. 误动
C. 正向故障拒动或反向故障误动
D. 损坏。

四川大学智慧树知到“电气自动化”《电力系统远动及调度自动化(1)1354》网课测试题答案卷1

四川大学智慧树知到“电气自动化”《电力系统远动及调度自动化(1)1354》网课测试题答案卷1

四川大学智慧树知到“电气自动化”《电力系统远动及调度自动化(1)1354》网课测试题答案(图片大小可自由调整)第1卷一.综合考核(共10题)1.远动终端的基本功能有()。

A.模拟量采集B.开关量采集C.遥控遥调信号输出D.与调度端通信2.发电厂变电站通过通信通道传输的信号包括()。

A.远动信号B.载波信号C.微波信号D.话音信号3.负荷预测主要针对()。

A.无功负荷B.有功负荷C.工业负荷D.居民负荷4.长距离输电线路轻载或空载时受端电压将()。

A.下降B.上升C.不变D.不确定5.状态信息是能方便采集和传送的状态参数。

()A.错误B.正确6.数据传输速率一般不可能采用的是()。

A.600B.2400C.9800D.192007.要实时地、总体地监测优化控制电力系统运行必须安装()。

A.继电保护设备B.自动发电控制系统C.能量管理系统D.励磁调节系统8.为降低通道中干扰的影响状态信息需要进行()。

A.状态信息组织B.状态信息更新C.状态估计D.状态信息预处理9.远动系统仅由厂站端远动终端和调度端远动装置构成。

()A.错误B.正确10.调度自动化系统需要在厂站装设()。

A.EMSB.AGCC.RTUD.CRT第1卷参考答案一.综合考核1.参考答案:ABCD2.参考答案:AD3.参考答案:B4.参考答案:B5.参考答案:B6.参考答案:C7.参考答案:C8.参考答案:D9.参考答案:A10.参考答案:C。

《电力系统分析基础(1)1350》18春在线作业1-0001

《电力系统分析基础(1)1350》18春在线作业1-0001

《电力系统分析基础(1)1350》18春在线作业1-0001A:B:C:答案:AA:B:C:答案:B 架空输电线路各序参数的特点有( ) A:正序参数与负序参数相等 B:正序参数大于负序参数 C:零序参数大于正序参数 D:零序参数大于负序参数 E:架空地线使等值的零序阻抗参数减小答案:A,C,D,E 电力系统中枢点的调压方式有( ) A:顺调压 B:改变变压器的变比调压 C:逆调压 D:常调压 E:发电机调压答案:A,C,D 功角δ的物理意义为( ) A:作为电磁参数代表发电机q轴电势之间的夹角 B:作为继续参数代表发电机转子之间的相对位置 C:各发电机机端电压之间的夹角D:0 答案:A,B 电力系统中消耗感性无功功率的元件有( ) A:白织灯 B:异步电动机 C:电容器 D:变压器 E:输电线路答案:B,D,E 短路冲击电流是短路电流的最大有效值。

A:错误 B:正确答案:A 不对称故障一般采用对称分量法进行分析。

A:错误 B:正确答案:B 电力系统二次调频可以实现无差调节。

A:错误 B:正确答案:B 采用自动重合闸将使最大可能的减速面积减小。

A:错误 B:正确答案:A 最大可能的减速面积大于加速面积,系统将失去暂态稳定。

A:错误 B:正确答案:A 按等微增率准则分配负荷将使系统的燃料消耗最少。

() A:错误 B:正确答案:B 输电线路的零序阻抗等于正序阻抗。

() A:错误 B:正确答案:A 逆调压是大负荷时升高电压,小负荷时降低电压的调压方式。

() A:错误 B:正确答案:B 电力系统电压大小主要受有功功率影响。

A:错误 B:正确答案:A 提高输电电压将提高系统输送功率的极限。

() A:错误 B:正确答案:B。

四川大学《电力系统自动装置(1)2353》21秋在线作业1

四川大学《电力系统自动装置(1)2353》21秋在线作业1

《电力系统自动装置(1)2353》21秋在线作业1
1:电力系统运行中的主要并列方式为
A、自同期
B、非同期
C、准同期
D、同周期
答案:C
2:小型机组的励磁调节方式一般为
A、微分调节
B、比例调节
C、比例微分调节
D、比例积分调节
答案:B
3:最简单的励磁调节器的调节方式是
A、微分调节
B、比例调节
C、比例微分调节
D、比例积分调节
答案:B
4:按提前量的不同,准同期并列装置可分为恒定越前相角和
A、恒定越前功率
B、恒定越前频率
C、恒定越前电压
D、恒定越前时间
答案:D
5:单侧电源线路的自动重合闸的主要特点是
A、存在同步问题
B、可能存在可能不存在同步问题
C、不存在同步问题
D、以上均不正确
答案:C
6:12脉波桥式整流电路的整流元件数为
A、6
B、12
C、18
D、24
答案:B
7:双电源线路配置重合闸装置除满足基本要求外,还该考虑
A、电压幅值
B、有功功率匹配
C、无功功率匹配
D、同步问题
答案:D
8:能够有效地提高系统稳定的功率极限的装置有
A、调速器。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
D.正序参数与负序参数相等
E.架空地线使等值的零序阻抗参数减小
答案:ABDE
4.电力系统中枢点的调压方式有( )
A.顺调压
B.逆调压
C.改变变压器的变比调压
D.常调压
E.发电机调压
答案:ABD
5.功角δ的物理意义为( )
A.各发电机机端电压之间的夹角
B.作为继续参数代表发电机转子之间的相对位置
C.作为电磁参数代表发电机q轴电势之间的夹角
Байду номын сангаасD.0
答案:BC
6.电力系统中消耗感性无功功率的元件有( )
A.输电线路
B.白织灯
C.电容器
D.异步电动机
E.变压器
答案:ADE
三、判断题(共10道试题,共40分)
7.短路冲击电流是短路电流的最大有效值。
答案:错误
8.不对称故障一般采用对称分量法进行分析。
答案:正确
9.电力系统二次调频可以实现无差调节。
《电力系统分析基础(1)1350》18春在线作业1-0001
试卷总分:100得分:100
一、单选题(共2道试题,共40分)
1.
A.
B.
C.
答案:A
2.
A.
B.
C.
答案:B
二、多选题(共4道试题,共20分)
3.架空输电线路各序参数的特点有( )
A.零序参数大于负序参数
B.零序参数大于正序参数
C.正序参数大于负序参数
答案:正确
10.采用自动重合闸将使最大可能的减速面积减小。
答案:错误
11.最大可能的减速面积大于加速面积,系统将失去暂态稳定。
答案:错误
12.按等微增率准则分配负荷将使系统的燃料消耗最少。()
答案:正确
13.输电线路的零序阻抗等于正序阻抗。()
答案:错误
14.逆调压是大负荷时升高电压,小负荷时降低电压的调压方式。()
答案:正确
15.电力系统电压大小主要受有功功率影响。
答案:错误
16.提高输电电压将提高系统输送功率的极限。()
答案:正确
相关文档