环洋变频器资料
160_30AB变频器资料

Allen-Bradley 1The Bulletin 160 is a microprocessor controlled adjustable frequency drive designed for reliable control of three-phase induction motors. The drive produces a three-phase, PWM, adjustable frequency output to vary the motor speed. Output voltage is a function of output frequency and is adjustable to meet motor parameters so that optimum motor performance can be obtained.ContentsConformity to StandardsThe Bulletin 160 and 160Z conforms to the following standards:➊External components and proper guidelines must be followed. Refer to the 160 User Manual,publication 0160-5.15 for details.➋Standards apply to 160 Standard Packaged Drives only.Description160 Standard Product 160Z Standard Product Packaged ProductConformity to Standards page 1page 1page 1Descriptionpage 2page 5page 8Catalog Number Explanation page 2page 5page 8Product Selection page 2page 5page 8Options & Accessories page 3page 6page 9Approximate Dimensions–page 7page 10Conformity to:Standard ProductPackaged ProductUL Listed (UL 508C)✔ ✔➋CSA Certified (C-UL)✔ CSA 22.2✔➋IEC Classified ✔CE Approved ➊EMC DirectiveLow Voltage Directive ✔EN61800-3, EN50081-1,EN50082-2EN50178, EN60204-1✔EN61800-3➋EN60204-1VDE Approved ✔C-Tick✔✔ AS/NZS2064.1➋2Allen-BradleyBulletin 160 Standard DrivesThis program includes standard Bulletin 160 drives rated from 0.37-4.0 kW (0.5-5.0 HP). Bulletin 160 drives are available in IP20(NEMA Type 00) and chassis mount (external heatsink) designs. The chassis mount product meets IP40/54/65 (NEMA 1/4/12/4X) ratings when installed in an enclosure of like rating. Chassis mount Bulletin 160 drives rated from 0.37-2.2 kW (0.5-3.0 HP) are available.Catalog Number DescriptionProduct Selection160 Drives➊The Bulletin 160 comes standard with a Ready/Fault indication panel. To order a drive with aProgram Keypad Module installed, add suffix P1 to the catalog number.Example: Catalog Number 160-AA02NSF1 becomes 160-AA02NSF1P1. See Table.➋Meets IP40/54/65 (NEMA 1/12/4/4X) when installed in an enclosure of like rating.160–AA02NSF1P1Bulletin NumberDrive Rating (must be specified)Enclosure Rating (must be specified)Control Method (must be specified)Programmer (Optional)Mounting Input Voltage Rating Drive Ratings Analog Signal Follower Model Preset Speed Model kW HP OutputCurrent Rating Catalog Number ➊❋Catalog Number ➊❋IP 20Open Style200-240V 50/60 Hz 1 Phase 0.37 1/2 2.3A 160S - AA02NSF1160S - AA02NPS10.55 3/4 3.0A 160S - AA03NSF1160S - AA03NPS10.75 1 4.5A 160S - AA04NSF1160S - AA04NPS11.5 28.0A 160S - AA08NSF1160S - AA08NPS1200-240V 50/60 Hz 3 Phase0.37 1/2 2.3A 160 - AA02NSF1160 - AA02NPS10.55 3/4 3.0A 160 - AA03NSF1160 - AA03NPS10.75 1 4.5A 160 - AA04NSF1160 - AA04NPS11.5 28.0A 160 - AA08NSF1160 - AA08NPS12.2 312.0A 160 - AA12NSF1160 - AA12NPS14.0518.0A 160 - AA18NSF1160 - AA18NPS1380-460V 50/60 Hz 3 Phase0.37 1/2 1.2A 160 - BA01NSF1160 - BA01NPS10.55 3/4 1.7A 160 - BA02NSF1160 - BA02NPS10.75 1 2.3A 160 - BA03NSF1160 - BA03NPS11.5 2 4.0A 160 - BA04NSF1160 - BA04NPS12.2 3 6.0A 160 - BA06NSF1160 - BA06NPS14.0510.5A160 - BA10NSF1160 - BA10NPS1Mounting Input Voltage Rating Drive Ratings Analog Signal Follower ModelPreset Speed Model kW HP OutputCurrent Rating Catalog Number ➊❋Catalog Number ➊❋IP 20Chassis Mount ➋200-240V 50/60 Hz 1 Phase 0.37 1/2 2.3A 160S - AA02PSF1160S - AA02PPS10.55 3/4 3.0A 160S - AA03PSF1160S - AA03PPS10.75 1 4.5A 160S - AA04PSF1160S - AA04PPS11.5 28.0A 160S - AA08PSF1160S - AA08PPS1200-240V 50/60 Hz 3 Phase0.37 1/2 2.3A 160 - AA02PSF1160 - AA02PPS10.55 3/4 3.0A 160 - AA03PSF1160 - AA03PPS10.75 1 4.5A 160 - AA04PSF1160 - AA04PPS11.5 28.0A 160 - AA08PSF1160 - AA08PPS12.2312.0A 160 - AA12PSF1160 - AA12PPS14.0518.0A 160 - AA18PSF1160 - AA18PPS1380-460V 50/60 Hz 3 Phase0.37 1/2 1.2A 160 - BA01PSF1160 - BA01PPS10.55 3/4 1.7A 160 - BA02PSF1160 - BA02PPS10.75 1 2.3A 160 - BA03PSF1160 - BA03PPS11.5 2 4.0A 160 - BA04PSF1160 - BA04PPS12.2 3 6.0A 160 - BA06PSF1160 - BA06PPS14.0510.5A160 - BA10PSF1160 - BA10PPS1DescriptionCode Program Keypad Module, Factory Installed P1❋ Contact Sales Office for PricingAllen-Bradley 3User Installed OptionsOperator Interface & Communication Devices➊Requires Remote Programming Adaptor (160-RPA) and cable (160-Cxx) to be operational.➋Includes 10 pin DeviceNet Connector.AccessoryCatalog No.❋Ready/Fault Indicating PanelIndicates if the drive is READY for operation or if a FAULT condition has occurred. This is standard if P1 is not factory installed.160-B1Program Keypad ModuleModule to program and/or monitor drive parameters as well as provide local keypad control (start, stop and reverse functions).160-P1Remote Keypad ModuleModule for remote mounting. Has program, monitor and operator interface capability.160-P2 ➊CopyCat Keypad ModuleHand held module with upload/download capability to program, monitor and control drive.160-P3 ➊Remote Programming AdapterInterface connection for the Remote and CopyCat Keypad modules.160-RPACablesConnects the Remote Programming Adapter to either the Remote or CopyCat Keypad Module.- 1 meter cable, non-locking each end- 1 meter cable, non-locking each end, right angle (for minimal depth)- 3 meter cable, locking each end - 5 meter cable, locking each end 160-C10160-C10R 160-C30160-C5024V DC Interface Module24V DC control interface. Bulletin 160 Series C drives must use a Series B, or later, 24V DC Interface module.160-DM-SF1(Analog model)160-DM-PS1(Preset model)Communication ModulesAllow control and monitoring of parameters via the networks listed below. These modules add 21.4 mm (0.85 in.) to the overall depth of the drive.-DeviceNet™-RS-232 Serial Communication -Profibus -Interbus160-DN2 ➋160-RS1160-PD1160-IB1DriveExplorer™ SoftwareWindows based software package that provides an intuitive means for monitoring or configuring Allen-Bradley drives and communication adapters.See Publication 9306-PL001A-EN-P .Common Mode Chokes ➌Open Style, used to enhance noise immunity.1A - used with communications and signal cables 9A - (with terminal block) used with all 160 drives1321-M0011321-M009❋ Contact Sales Office for PricingRS-232 Serial Communication Module160-RS1DeviceNetCommunication Module160-DN2Remote ProgrammingAdapter 160-RPACopyCat KeypadModule 160-P3Remote KeypadModule160-P2Program KeypadModule 160-P1ProfibusCommunication Module160-PD1InterbusCommunication Module160-IB14Allen-BradleyUser Installed Accessories – All Drive Ratings➊Must order two for a 4.0 kW (5 HP) application. The two dynamic brake modules must be wiredin parallel.➋Catalog numbers listed are for 3% impedance open style units. NEMA 1 and 5% impedancereactor types are also available, refer to Publication 1321-2.0 for detailed information. Use the line reactor for rated application to attain proper impedance.➌Catalog No. 1204-RWR-09-B.➍Reflected Wave Reduction Modules (1204-RWR-09-B) may be used at a 10.5 Amp current ratingproviding the drive to motor cable length is less than 122 meters (400 feet).➎Must mount separately when used with Series C drives.Input Voltage Rating Drive Ratings Dynamic Brake Modules Line Reactors Open Style ➋Fan Replacement KIts kW H P Catalog No.❋Catalog No.➋❋Series CDrive Cat. No.❋200-240V 50/60 Hz 1 Phase 0.37 1/2———0.55 3/4———0.75 1160 - BMA1—160-FRK21.5 2160 - BMA2—160-FRK3200-240V 50/60 Hz 3 Phase0.37 1/2—1321-3R4-B —0.55 3/4—1321-3R4-A —0.75 1160 - BMA11321-3R4-A 160-FRK21.5 2160 - BMA21321-3R8-A 160-FRK22.2 3160 - BMA21321-3R12-A 160-FRK24.05160 - BMA2➊1321-3R18-A 160-FRK3380-460V 50/60 Hz 3 Phase0.37 1/2—1321-3R2-B —0.55 3/4—1321-3R2-A —0.75 1160 - BMB11321-3R2-A 160-FRK21.5 2160 - BMB21321-3R4-B 160-FRK22.2 3160 - BMB21321-3R8-B 160-FRK24.05160 - BMB2➊1321-3R8-B160-FRK3Input Voltage Rating Drive Ratings Line Filters Capacitor Modules kW HPClass A Only Class A & B Catalog No.❋Catalog No.❋Catalog No.❋200-240V 50/60 Hz 1 Phase 0.37 1/2160S-L FA1160S-RFA-9-A 160-CMA10.55 3/4160S-L FA1160S-RFA-9-A 160-CMA10.75 1160S-L FA1160S-RFA-9-A 160-CMA11.5 2160S-L FA1➎160S-RFA-16-B ➎160-CMA1200-240V 50/60 Hz 3 Phase0.37 1/2160-L FA2160-RFB-5-A 160-CMA10.55 3/4160-L FA2160-RFB-5-A 160-CMA10.75 1160-L FA2160-RFB-5-A 160-CMA11.5 2160-L FA2160-RFB-14-A 160-CMA12.2 3160-L FA2160-RFB-14-A 160-CMA14.0 5—160-RFA-22-B ➎160-CMA1380-460V 50/60 Hz 3 Phase ➌ ➍0.37 1/2160-L FB1160-RFB-5-A 160-CMB10.55 3/4160-L FB1160-RFB-5-A 160-CMB10.75 1160-L FB1160-RFB-5-A 160-CMB11.5 2160-L FB1160-RFB-5-A 160-CMB12.2 3160-L FB1160-RFB-14-A 160-CMB14.05—160-RFB-14-B ➎160-CMB1❋ Contact Sales Office for PricingAllen-Bradley 5Bulletin 160Z Standard DrivesThe Allen-Bradley Bulletin 160Z drive is the newest drive within the Bulletin 160 product line. Designed to meet user demands for motor control in wash-down or zero-cabinet environments, the 160Z drive features NEMA Type 4X/IP65 rated protection and networkconnectivity in a compact, space-saving design. Each drive package delivers a user specified, space efficient control solution for three-phase motors, ranging from 0.37 to 2.2 kW (0.5 to 3 HP) at 200 to 240 volts and from 0.37 to 4 kW (0.4 to 5 HP) at 380 to 460 volts. Additional option kits are available for user installation (see page 6).Ordering InstructionsWhen ordering a 160Z drive without a motor, consider the following.•Select basic Catalog Number based on application requirements (i.e. V oltage, Horsepower and Integral CE Filter). For example: a 380-460V three phase, 0.75 kW (1 HP) drive without CE filter is: 160Z-BA04SFNNN•Select 160Z-WMK wall mount kit.•Select wiring glands if necessary: 160Z-G25 for incoming power and 160Z-G16 for communications or I/O wiring.•Select other accessories as needed.Catalog Number DescriptionProduct Selection 160Z Drives➊When using 160Z as wall mount, communication modules should be ordered as separate options.See page 6.➋For 160Z drives mounted on motors, consult factory.160Z –AA02FSNN ➊NBulletin NumberDrive Rating (from table below)Enclosure Rating NEMA 4X (IP65)Control Method (analog signal follower)Filter Option (must be specified)Communication(None)Motor (None)InputVoltage Rating Drive Ratingwithout motor ➋with integral CE filter kW HP Output Current Rating Catalog Number ❋Catalog Number ❋200-240V,50/60 Hz,3-Phase0.370.5 2.3A 160Z-AA02FSNNN —0.550.753A 160Z-AA03FSNNN —0.751 4.5A 160Z-AA04FSNNN —1.528A 160Z-AA08FSNNN —2.2312A 160Z-AA12FSNNN —380-460V,50/60 Hz,3-Phase0.370.5 1.2A 160Z-BA01FSNNN 160Z-BA01FSFNN 0.550.75 1.7A 160Z-BA02FSNNN 160Z-BA02FSFNN 0.751 2.3A 160Z-BA03FSNNN 160Z-BA03FSFNN 1.524A 160Z-BA04FSNNN 160Z-BA04FSFNN 2.23 5.2A 160Z-BA06FSNNN 160Z-BA06FSFNN 458.1A160Z-BA10FSNNN160Z-BA10FSFNN❋ Contact Sales Office for Pricing6Allen-BradleyUser Installed Options/AccessoriesOperator Interface ➊, Communication Devices & Accessories➊160-P1 is not compatible with 160Z drives.➋ A 160-RPA is not required with 160Z drives. 160-RPA circuitry is included as standard.➌Includes 10 pin DeviceNet Connector.➍For mounting with Allen-Bradley 1329RS motors, cast iron, severe duty.➎For mounting with SEW, D-Type IEC motors.➏Maximum continuous output is 3.0 kW at 40°C and 4 kHz, 3.7 kW at 35°C and 2 kHz.AccessoryCatalog No.❋Remote Keypad ModuleModule for remote mounting. Has program, monitor and operator interface capability.160-P2CopyCat Keypad ModuleHand held module with upload/download capability to program, monitor and control drive.160-P3Cables ➋Connects the 160Z to either the Remote or CopyCat Keypad Module.- 1 meter cable, locking each end - 3 meter cable, locking each end - 5 meter cable, locking each end160Z-C10160Z-C30160Z-C50Communication Modules and AccessoriesAllow control and monitoring of parameters via the networks listed below. These modules can be mounted inside the 160Z.-DeviceNet™-RS-232 Serial Communication -Profibus -Interbus-RS232 Communication Terminal Block -Profibus Communication Terminal Block-Interbus In/Out Communication Terminal Block -Interbus Side Metal plate (5 holes)160-DN2 ➌160-RS1160-PD1160-IB1160Z-RTB 160Z-PTB 160Z-ITB 160Z-ISM Motor Adapters-NEMA motor, 0.5 - 2 HP ➍-NEMA motor, 3 - 5 HP ➍-SEW, IEC Motor, 0.37-1.5 kW ➎-SEW, IEC Motor, 2.2 kW ➎-SEW, IEC Motor, 3.7 kW ➎➏160Z-ABN1160Z-ABN2160Z-SEW1160Z-SEW2160Z-SEW3Hardware-Power cable glands-Motor cable glands, wall mounting only -Communication and I/O cable glands 160Z-G25160Z-G20160Z-G16Dynamic Brake Resistors -0.5 - 1 HP (0.37 - 0.75 kW)- 2 - 3 HP (1.5 - 2.2 kW)- 5 HP (3.7 kW)160Z-BMB1160Z-BMB2160Z-BMB3Accessories-Debris cover, motor mount -Debris cover, wall mount -Fan replacement kit-Spare gasket kit (includes all gaskets)-Wall mounting kit (includes one 160Z-G20)-Wall mount adapter 160Z-DC 160Z-DCW 160Z-FRK 160Z-GSK 160Z-WMK 160Z-WMADriveExplorer™ SoftwareWindows based software package that provides an intuitive means for monitoring or configuring Allen-Bradley drives and communication adapters.See Publication 9306-PL001A-EN-P .RS-232 Serial Communication Module160-RS1DeviceNetCommunication Module160-DN2CopyCat KeypadModule 160-P3Remote KeypadModule 160-P2ProfibusCommunication Module160-PD1InterbusCommunication Module160-IB1❋ Contact Sales Office for PricingWall Mounted DimensionsAllen-Bradley7❋ Contact Sales Office for PricingBulletin 160 Standard Packaged Drives The Standard Packaged Drive Program allows users to create drive packages based on their specific needs. A complete drive package may be specified by assembling a single catalog number string that includes a base drive, enclosure and all required options.Ordering Instructions•Select basic Catalog Number based on application requirements(i.e. V oltage, Horsepower, Control Model and EnclosureRatings). For example: a 200-240V three phase, 0.37 kW (1/2HP), analog signal follower model and an IP66 (NEMA 4/12)enclosure is: 160-AA02SF1-AF•Select Enclosure Options and follow the Option Rules. For example: the catalog number with a fused disconnect switch with Start-Stop pushbuttons is: 160-AA02SF1 -AF- DS-D17 Compliance certificationsSee page1 for compliance information. When the “EMC” option is selected, the product will ship with an RFI filter. If the “EMC” option is not selected, reference the Bulletin 160 Series C User Manual for proper installation instructions.Custom Drives ProgramDrive packages that cannot be ordered via a catalog number can be customized to meet user requirements for specific options such as special enclosure sizes and colors, terminal blocks, wire type, etc. Contact factory.Catalog Number DescriptionProduct Selection 160–AA02SF1–AF–DS–D17 BulletinNumberDrive Rating(must be specified)Enclosure Rating(must be specified)Options(as required)Input Voltage Rating Drive RatingsIP 66 (NEMA 4/12)IP66 (NEMA 4X - 304 Stainless Steel)Analog SignalFollower Model Preset Speed ModelAnalog SignalFollower Model Preset Speed ModelkW H POutput CurrentRating Catalog No.Catalog No.❋Catalog No.Catalog No.❋200-240V 50/60 Hz 1 Phase 0.37 0.5 2.3A160S - AA02SF1-AF160S - AA02PS1-AF160S-AA02SF1-AS160S - AA02PS1-AS 0.55 0.75 3.0A160S - AA03SF1-AF160S - AA03PS1-AF160S-AA03SF1-AS160S - AA03PS1-AS0.75 1 4.5A160S - AA04SF1-AF160S - AA04PS1-AF160S-AA04SF1-AS160S - AA04PS1-AS1.5 28.0A160S - AA08SF1-AF160S - AA08PS1-AF160S-AA08SF1-AS160S - AA08PS1-AS200-240V 50/60 Hz 3 Phase 0.37 0.5 2.3A160 - AA02SF1-AF160 - AA02PS1-AF160-AA02SF1-AS160 - AA02PS1-AS 0.55 0.75 3.0A160 - AA03SF1-AF160 - AA03PS1-AF160-AA03SF1-AS160 - AA03PS1-AS0.75 1 4.5A160 - AA04SF1-AF160 - AA04PS1-AF160-AA04SF1-AS160 - AA04PS1-AS1.5 28.0A160 - AA08SF1-AF160 - AA08PS1-AF160-AA08SF1-AS160 - AA08PS1-AS2.20 312.0A160 - AA12SF1-AF160 - AA12PS1-AF160-AA12SF1-AS160 - AA12PS1-AF 4.0518.0A160 - AA18SF1-AF160 - AA18PS1-AF160-AA18SF1-AS160 - AA18PS1-AF380-460V 50/60 Hz 3 Phase 0.37 0.5 1.2A160 - BA01SF1-AF160 - BA01PS1-AF160-BA01SF1-AS160 - BA01PS1-AS 0.55 0.75 1.7A160 - BA02SF1-AF160 - BA02PS1-AF160-BA02SF1-AS160 - BA02PS1-AS0.75 1 2.3A160 - BA03SF1-AF160 - BA03PS1-AF160-BA03SF1-AS160 - BA03PS1-AS1.5 2 4.0A160 - BA04SF1-AF160 - BA04PS1-AF160-BA04SF1-AS160 - BA04PS1-AS2.2 3 6.0A160 - BA06SF1-AF160 - BA06PS1-AF160-BA06SF1-AS160 - BA06PS1-AS 4.0510.5A160 - BA10SF1-AF160 - BA10PS1-AF160-BA10SF1-AS160 - BA10PS1-AS❋ Contact Sales Office for Pricing8Allen-BradleyAllen-Bradley 9Factory Installed Enclosure Options➊Includes 10 pin DeviceNet Connector.➋If a (P1C), (DN2C), (RS1C), (RPAC) or (P2C) is not specified, the drive is supplied with a factory installed “Ready/Fault” indicating panel as standard.➌120V AC Separate Control Power Required.➍Remote Keypad Module option includes the RPA and cable.➎ 5 pin DeviceNet Connectors are Brad Harrison type. See dimensions/locations on page 11.➏DN2C option must be selected. See page 11 for connector locations.➐Enclosure dimensions for 1/2 - 2 HP are 8.44"W x 17"H x 9.15"D with or w/o disconnect and for 3 HP 9.61"W x 16.5"H x 9.46"D with or w/o disconnect.➑Option is not CE/C-Tick.➒When catalog string contains a communication module, D32 must be used with D33 or D13 except with option P2C. When used with option P2C, must be used with D13.Option RulesDescriptionOption Code ❋Cannot be used withOperator Interface:DeviceNet Module (Drive Mounted) ➊- DN2C D17, P1C, P2C, Ready/Fault, RPAC, RS1C, PD1C, IB1CRS-232 Serial Communication Module (Drive Mounted)- RS1C D17, DN2C, P1C, P2C, Ready/Fault, RPAC, PD1C, IB1C, MX14Profibus Module (Drive Mounted)- PD1C DN2C, PIC, RS1C, Ready/Fault, RPAC, P2C, D17, IB1C, MX14Interbus Module (Drive Mounted)- IB1C PIC, RS1C, Ready/Fault, RPAC, P2C, D17, PD1C, DN2C, MX14DeviceNet I/O Relay - 24VDC input/relay output w/5 point DeviceNet connector.- DNRC ➐EMCReady/Fault Panel- ➋DN2C, P1C, P2C, RPAC, RS1C, MX14, PD1C, IB1CProgram Keypad Module (Drive Mounted)- P1C D17, DN2C, P2C, Ready/Fault, RPAC, RS1C, MX14, PD1C, IB1C Remote Programming Adapter- RPAC D17, DN2C, P1C, P2C, Ready/Fault, RS1C, MX14, PD1C, IB1C Remote Keypad Module (Door Mounted)- P2C ➍➐D17, D33, DN2C, Ready/Fault, P1C, RPAC, RS1C, MX14, PD1C, IB1CFused Disconnect Switch (Class J Fuses)- DS Cover Mounted Devices:“Hand -Off-Auto” Selector Switch - D13D17, D33, MX12, MX19“Start-Stop” Push buttons- D17D13, D33, DN2C, MX12, MX19, P1C, P2C, RPAC, RS1C “Forward/Reverse” Selector Switch - D32 ➒MX12, MX19“Local/Remote” Selector Switch - D33D13, D17, MX12, MX19White “Drive Run” Pilot Light ➌- D35D36, MX12, MX19Red “Drive Fault” Pilot Light ➌- D36D35, MX12, MX19“Speed” Potentiometer- D61MX12, MX19, All Preset Speed Models“Local/Remote” & “Local Control Off/Run Forward” 800T Selector Switches- MX12AS, D13, D17, D32, D33, D35, D36, D61, MX19“Local/Off/Remote” 800T Selector Switch with One N.O. Interposing Relay- MX19AS, D13, D17, D32, D33, D35, D36, D61, MX12, MX14Control Interface Cards:24V DC Interface Card for Analog Model- DMSF1C DMPS1C, LTN120, All Preset Speed Models 24V DC Interface Card for Preset Speed Model- DMPS1C DMSF1C, LTN120, All Analog Models 120V AC Interface Card for Analog and Preset Speed Models - LTN120 ➑DMPS1C, DMSF1CDeviceNet Enclosure Mounted Connector Options:Nema 4/12 5 pin connector side mounted ➎- DNSC1 ➏DNSC2, DNBC1, DNBC2, P1C, P2C, RPAC, RS1C, STD Ready/Fault Nema 4x 5 pin connector side mounted ➎- DNSC2 ➏DNSC1, DNBC1, DNBC2, P1C, P2C, RPAC, RS1C, STD Ready/Fault Nema 4/12 5 pin connector bottom mounted ➎- DNBC1 ➏DNSC1, DNSC2, DNBC2, P1C, P2C, RPAC, RS1C, STD Ready/Fault Nema 4x 5 pin connector bottom mounted ➎- DNBC2 ➏DNSC1, DNSC2, DNBC1, P1C, P2C, RPAC, RS1C, STD Ready/Fault Electro Magnetic Compatibility - EMC ➐LTN120, DNRCMotor Brake Option:Motor Brake Contactor and Surge Suppressor(100M cont. 24V powered off DeviceNet Option), DN2C- MX14 ➏➐D35, D36, MX19, P1C, P2C, RPAC, RS1C, Ready/Fault, PD1C, IB1COptionDescriptionMaximum Number of Cover Devices0.37-1.5 kW (0.5-2 HP) without a disconnect or Remote Keypad Module or MX14 or EMC or DNRC is 4.2.2-4.0 kW (3-5 HP) w/o a disconnect or Remote Keypad Module and all drives with a disconnect, MX14 or DNRC or EMC is 5.0.37-4.0 kW (0.5-5 HP) with the Remote Keypad Module is3.i.e. Start-Stop (D17)= 2 Cover Devices Forward-Reverse (D32)= 1 Cover Device White Run Pilot Light (D35)= 1 Cover Device= 4 TotalFactory Installed Enclosure Option Catalog Configuration When ordering, build the catalog string in the following manner: Bulletin number, drive rating, control model, enclosure type and options. Note: Options are to be configured in alpha-numeric sequence.❋ Contact Sales Office for PricingApproximate Dimensions10Allen-BradleyBulletin 160Adjustable Frequency AC DriveAllen-Bradley 11Figure 5– DeviceNet Connector Option Locations Use above dimensions for Figure 2 & Figure 3Use above dimensions for Figure 1Use above dimensions for Figure 2 & Figure 3Use above dimensions for Figure 1Dimensions are in millimeters (inches) and are not to be used for manufacturing purposes Use above dimensions for Figure 4Use above dimensions for Figure 4DNBC1 and DNBC2DNSC1 and DNSC2。
变频器调试说明.docx

真理惟一可靠的标准就是永远自相符合。
土地是以它的肥沃和收获而被估价的;才能也是土地,不过它生产的不是粮食,而是真理。
如果只能滋生瞑想和幻想的话,即使再大的才能也只是砂地或盐池,那上面连小草也长不出来的。
1.变频器上电,修改参数访问级别。
首先选中变频器,按键,然后按键,选择Ports,选择“ 00 PowerFlex 753”,按 ESC键,退到主界面。
设置P301=1 快速访问方法按 PAR#键,输入访问的参数号,如3012.完成变频器Start-up 向导按键,然后按键,选中Start-up菜单,进入启动向导。
启动向导结构如下:①选择”Begin Start Up”,按确认键进入。
面板提示“ Start-Up consists of several steps to configure the drive.Press Enter ”,按“Enter”键确认。
面板提示②“ Geneal Startup”“Appl Specific“选择“ Geneal Startup”,按“ Enter“键确认③面板显示:“Motor Control ”“Motor Data ”“Feedback”“Limits”产的不是粮食,而是真理。
如果只能滋生瞑想和幻想的话,即使再大的才能也只是砂地或盐池,那上面连小草也长不出来的。
“Ref Ramp Stop““I/O”顺序选择以上菜单进入④选择”Motor Control ”菜单,面板显示”This section select the type of Motor Control the drive will use.PressEnter”,按“ Enter”键确认面板显示:“Please Select:Sensorless VectV/HzFlux Vector”对于原料变频器,选择“Sensorless Vect”无速度传感器矢量,对于烧结机一台变频器带两台电机应用,选择“V/Hz”⑤“Motor Control 设”置完成后,选择“M otor Data ”,按“ Enter”确认变频器面板显示“Edit Motor NP Volts ”“400 VAC”按”Enter”确认⑥变频器面板显示“Select type of power units shown on motor nameplateHPKW”选择”KW”,按“ Enter”键确认⑦ 变频器面板显示“Edit Motor NP PowerXX KW”,输入电机额定功率(使用软按键,删除原有显示值再输入电机功率值),按”Enter”键确认⑧ 变频器面板显示“Edit Motor NP Amps ”产的不是粮食,而是真理。
变频器说明介绍模板大全之令狐文艳创作

目录令狐文艳一、用户须知2二、注意事项3三、系统简介 4四、输出逆变系统 5五、可控整流系统 40附录一维护与保养 54附录二、依照EMC导则进行传动装置设计的说明55一、用户须知1.1该变频调速装置为电力电子器件组成,在运输及安装过程中,尽量避免强烈的震动,尽量垂直运输。
1.2该变频调速装置尽量安装在干燥通风的区域,变频器的散热片距墙壁(或遮挡物)距离应大于1.0米。
1.3长期不用时,应存放在清洁干燥的地方;在井下安装好而不运行的状况下,该设备尽量不停电。
1.4 使用之前,必须详细阅读用户手册。
二、注意事项2.1变频调速装置其隔爆外壳体及本安控制盒的结构和非本安及本安电路的电气参数,在出厂前均已装配调试合格,用户严禁改动变频调速装置壳体的结构和电气参数,以确保本产品的防爆性能、电气性能和本安性能。
2.2设备在带电情况下,严禁松动隔爆壳紧固件,在检修或处理故障时,请注意“断电源后开盖”。
(注:本安接线腔不受此限制)2.3外壳应接地良好。
2.4电源接线隔爆腔在接线时请注意按图接线,不得接错。
2.5装置防爆主腔内进行操作时,手上必须带接地导线或静电环。
2.6装置电源R、S、T停电以后5分钟内禁止对变频器隔爆主腔内的任意电路进行操作,且必须用仪表确认机内电容已放电完毕,方可实施机内作业。
停电以后1分钟内禁止再次给电。
2.7负载运行过程中尽量减少瞬时停电次数。
2.8禁止对变频器主回路及控制回路进行耐压试验,如对与变频有电路联系的相关设备进行耐压试验之前应将与变频相关的电路切断。
2.9测量变频器输出电压时必须使用整流式交流电压表,使用其它非整流式电压表测量高频脉冲电压时,容易产生误操作或显示不准确。
2.10变频器安装应远离大容量变压器及电动机(容量为变频器的10倍以上)。
2.11该系统输出端不可以加装进项电容或阻容吸收装置。
2.12该系统变频器箱与电抗器箱连接必须完全按照相关图纸,以保证反馈电压相序一致。
vacon变频器要点免费全文阅读

码
V1. 输出频率
H 电机的运行频率
1
Z
V1. 频率参考值
H
2
Z
V1. 电机速度 3
rp 电机速度的计算值 m
V1. 电机电流
A 电机电流的检测值
4
VACON变频器简介
信号 单
描
代 名称
位述
码
V1. DIN1,DIN2,DIN3
数字输入状态
13
V1. DIN4,DIN5,DIN6 14
数字输入状态
VACON变频器简介
·控制面板介绍
VACON变频器简介
控制面板是变频器和用户连接的桥梁,VACON控制面板包括7个运行状态指示(RUN,正/反转,R EADY,STOP,ALARM,FAULT)和3个控制源(I/O端子/面板/总线通讯BUS 态指示LED绿(ULT)READY),绿(RUN),红(FAULT) 控制信息,例如菜单序号,菜单描述或显示值和数字信息将在三条文本行中给出. 变频器可以通过控制面板上的9个按钮来操作,另外还可以实现参数设置和数据监控的目的.
ห้องสมุดไป่ตู้
检查环境温度
检查与环境温度和电机负载相 比,开关频率没有过高
VACON变频器简介
代码
16
故障
电机过热
可能原因
-变频器由电机温度模型检测出电机过热 -电机过载
17
电机欠栽
电机欠载保护跳闸
22
EEPROM检
参数恢复出错
验故障
-故障操作
-器件失效
26
起动保护
变频器起动保护
29
热电阻故障 选件板的热负载电阻输入检测到电机温度的增
加
31
vacon nx系列变频器选件说明

Vacon NXP高性能工程型变频器
规格:FR4-FR14 安装: • 壁挂式,IP21或IP54(FR4-9) • 轻体式柜机,IP21或IP54(FR10和FR11) • IP00模块(FR9-FR14)
用于+Ix x选件的+A AC 辅助触点 此辅助触点用于检测主电源设备已闭合。它包括1个常开辅助触点 和1个常闭辅助触点。默认情况下,该触点连接到变频器的DIN3端 口。如果预定了+ICO(接触器),它会被安装在主电源设备上。
FR14 如需设计图,可登录 (需要密码)
Vacon NXP的最佳应用领域 • 对速度与转矩的静态及动态精度的要求较高:Vacon NXP可实
现闭环矢量控制,反馈装置可选择编码器或旋转变压器 • 主从同步,定位控制,卷取张力控制,同步或高速应用领域 • 需要IP00模块,12脉冲系统或水冷型变频器的应用
Vacon NXC的最佳应用领域 • 功率要求更高,防护等级为IP21或IP54,并独立装柜 • 需要输入(保险,开关,断路器),输出 (滤波器)设备或其它控制
Vacon NXL紧凑型变频器
规格:MF2和MF3 安装:壁挂式,防护等级IP20,背面或侧面安装
电压 208-240V,单相 208-240V,单相或三相 380-500 V
功率 0.25-0.37 kW 0.55-1.5 kW 0.37-2.2 kW
Vacon NXL紧凑型变频器的标准配置: • 制动斩波器(MF3) • 7段码(数字字符型显示)控制面板 • 两个模拟输入,一个模拟输出,三个数字输入,一个继电器输出,
变频器基础知识培训

四、变频器的调试
1、外围接线 2、绝缘测试 3、调试软件使用
1、外围接线
电网接线
转子接线
4
定子接线
6
主电路
5
外围接线
控制柜接线
编码器接线 7
8
控制电路 编码器 通讯
2、绝缘测试
1、电网侧绝缘测试(须断开防雷器) 2、定子侧绝缘测试(须确定断路器已断开) 3、转子侧绝缘测试(不允许) 注:变频器在出厂时做过严格的绝缘测试,所以在现场一般不需
变频器基础知识培训
REN双馈变频器
天津瑞能电气有限公司工程中心 冯林威 2013.05.05
一、变频器系统概述 二、变频器工作原理简介 三、变频器结构及各模块介绍 四、变频器的调试 五、变频器常见故障及处理 六、变频器相关安全注意事项
一、变频器系统概述
1、双馈变频器适用于双馈异步风力发电机系统。
并网发电命令执行开关,
当定子电压幅值、频率和 相位与电网电压幅值、频 率和相位相同时,并网发 电命令发出后,并网开关 即会闭合。当有故障发生 和停机命令时,并网开关 断开。
1.6、定子接触器
主要为减少主断路器的分合闸次 数,延长主断路器的使用寿命
1.6、电压传感器(包括电网侧和定子侧)
电压传感器: 检测电网线电压和定子线电压, 并将电压信号输入至4U控制器 的信号调理板中进行运算。
断开电网供电后,UPS供电 系统仍在工作,
在操作之前切断UPS输出!
CAUTION!
Hazardous
Voltage, Danger
of electric shock! Multiple
环洋变频器说明书

环洋变频器说明书(正文内容1500字)1. 环洋变频器简介环洋变频器是一种电气驱动设备,主要用于控制电动机的转速和运行效果。
它能够通过调节电源电压和频率,实现对电动机的精确控制,从而达到节能、降低噪音和提高生产效率的目的。
2. 产品特点2.1 高效节能环洋变频器采用先进的调速技术,能够自动监测负荷变化,并根据负荷大小实时调整电机转速和供电频率,以保持最佳运行效率。
相比传统的固定转速驱动方式,环洋变频器能够显著降低能耗,达到节能的目的。
2.2 稳定可靠环洋变频器具有良好的动态响应能力,能够快速调整电机转速并实现平稳运行。
同时,它还具备过载保护、短路保护、过电压保护等多重安全保护功能,保证设备运行的稳定性和可靠性。
2.3 简单操作环洋变频器采用直观的触摸屏界面,操作简单方便。
用户只需根据实际需求设置参数,即可实现精准控制。
此外,环洋变频器还支持多种通信接口,可与上位机或其他设备进行联网,实现监控和远程控制。
3. 产品应用环洋变频器广泛应用于各个领域,如工业制造、建筑、石油化工等。
具体应用包括:3.1 输送系统环洋变频器可用于输送机、输送带、风机等设备,实现对物料的准确传送和跟踪控制。
通过调整转速和频率,能够根据生产需求实现物料的高效运输和分配。
3.2 泵站系统环洋变频器可用于水泵、离心泵、污水泵等设备,实现对水流、液位和压力的控制。
它可以根据实际工况自动调整泵的运行状态,实现节能、稳定的水源供应。
3.3 制造业在制造业中,环洋变频器被广泛应用于机床设备、注塑机、压机等,实现对工艺过程的精确控制。
通过调整电机转速和频率,能够实现产品的精准加工和质量保证。
4. 使用说明4.1 安装与接线在安装环洋变频器时,需按照相关规定选择合适的安装位置,并留出足够的散热空间。
在接线方面,需要根据设备标识和电气图纸进行正确接线,确保电气连接牢固可靠。
4.2 参数设置安装完成后,需要根据实际应用需求进行参数设置。
通过触摸屏界面,可以设定电机额定转速、运行频率、过载保护等参数,以实现最佳的运行效果。
环洋HY01D523B变频器参数表

XXHY01D523B变频器参数表型号 HY01D523B 适用电机功率 1.875(KW)品牌 XX 额定容量 1.5(KVA)外形尺寸 168*124*161(mm)额定电流 7(A)产品特性:内置PID控制:先进的微积分PID闭环算法,响应快速且适应性强内置简易PLC功能,可实现16段速度控制和摆频控制功能内置RS485通讯接口,采用国际标准MODBUS总线控制协议具有超强的抗干扰能力,可轻松实现远程控制低频输出0.5HZ-150%额定转矩,低速运行动力澎湃16KHZ载波频率可调,完全静音运行宽电压工作范围,能在304V-456V正常工作自动稳压技术(AVR),保证变频器负载能力同步和异步控制多种控制技术,动态实现快速启动无跳闸具有完善的故障保护及短路启动保护功能一、项目名称XX变频器控制方式SPWM输入电源380V电源:330~440V;220V电源:170~240五位数码显示及状态指示灯显示频率、电流、转速、电压、计数器、温度、正反转状态、故障等。
二、通信控制RS-485操作温度-10~40℃湿度0~95%相对湿度(不结露)振动0.5G以下频率控制范围0.10~400.00Hz精度数字式:0.01%(-10~40℃);模拟式:0.1%(25±10℃)设定解析度数字式:0.01Hz;模拟式:最大操作频率的1‰输出解析度0.01Hz键盘设定方式可直接以←∧∨设定模拟设定方式外部电压0-5V,0-10V,4—20mA,0—20mA。
其它功能频率下限,启动频率,停车频率、三个跳跃频率可分别设定一般控制加减速控制加减速时间(0.1-6500秒)任意选择V/F曲线可任意设定V/F曲线三、转矩控制可设定转矩提升,最大10.0%启动转矩在1.0Hz时可达150%多功能输入端6个多功能输入端,实现8段速控制,程序运行,4段加减速切换,UP、DOWN机能、计数器,外部急停等功能多功能输出端有5个多功能输出端,实现运转中、零速、计数器、外部异常、程序运行等指示及报警其它功能自动电压稳压(AVR)、减速停止或自由停止、直流刹车,自动复位再起动,频率跟踪,PLC程序控制、横动控制、载波可调,最高达20KHz等四、保护功能过载保护电子电驿保护马达驱动器(恒转矩150%/1分钟,风机类120%/1分钟)FUSE熔断保护FUSE熔断,马达停止过电压220V线:直流电压>400V;380V线:直流电压>800V不足电压220V线:直流电压<200V;380V线:直流电压<400V瞬间停电再起动瞬停后可以频率跟踪方式再起动五、失速防止加/减速运转中失速防止输出端短路电子线路保护其它功能散热片过热保护,反转限制,开机后直接起动及故障复归之功能,参数锁定等。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
0
◎
Pr125
過轉矩檢測時間
0.1-20.0
0
◎
Pr126
脈衝計數器記憶
0:不記憶
1:記憶
0
◎
Pr127~129
保留
Pr130
輔泵個數
0~2
0
◎
恒
壓
供
水方面參數
Pr131
輔泵連續時間
1~9000mim
60
◎
Pr132
輔泵互鎖時間
1~250s
5s
◎
Pr133
高速運行時間
1~250s
60s
◎
Pr134
按機種設定
*
Pr174
變頻器額定電流
按機種設定
0
*
Pr175
變頻器類型
0:恒转矩1:风机类
*
Pr176
變頻器頻率標準
0:50Hz1:60Hz
0
*
Pr177
異常錯誤1
——表示無故障記錄。
◎
Pr178
異常錯誤2
——
◎
Pr179
異常錯誤3
——
◎
Pr180
異常錯誤4
——
◎
Pr181
軟件版本號
——
◎
Pr182
根據機型而定
◎
Pr042
點動頻率
0.00~400.00 Hz
5.00
◎
Pr043
S曲線時間
0~6500S
0
◎
Pr044
X1功能
0:無效1:運轉2:正轉3:反轉4:停止5:正/反轉6:寸動7:寸動正轉8:寸動反轉9:外控計時器一10:外控計時器二11:保留12:散熱器或電機過熱13:緊急停車14:復位15、16:保留17:加減速時間選擇一18:加減速時間選擇二19:多段速一20:多段速二21:多段速三22:高速23:中速24:低速25:PID允許27:遞增28:遞減29:牽伸允許31脈衝計數器32:脈衝計數器復位
Pr030
停車制動時間
0~25.0
0.0
◎
Pr031
直流制動量准位
0.0~20.0%
2.0
◎
Pr032
頻率跟蹤時間
0.1~20.0S
5.0
◎
Pr033
頻率跟蹤電流准位
0.0~200.0S
150.0
◎
Pr034
頻率跟蹤時電壓上升的時間
0.1-10S
0.5
◎
Pr035
~Pr040
保留
Pr041
載波頻率
0~15
0
◎
Pr078
遞增、遞減增量選擇
0:0.01HZ 1:0.1HZ
1
◎
Pr079
保留
Pr080
運行模式選擇
0:普通運行1:內控16段速2:外控四段速3:外控八段速4:牽伸5:擾動
0
◎
多
段
速方面參數
Pr081
內控多段速運行模式選擇
0:運轉一周後停止1:迴迴圈運行2:自動運行(STOP間隔)一周後停止3:自動運行(STOP間隔)迴圈運行
0.0
◎
Pr113
內控多段速計時器十三
0.0-6500.0S
0.0
◎
Pr114
內控多段速計時器十四
0.0-6500.0S
0.0
◎
Pr115
內控多段速計時器十五
0.0-6500.0S
0.0
◎
Pr116
內控多段速計時器十六
0.0-6500.0S
0.0
◎
Pr117
內控多段速記憶功能
0:不記憶
1:記憶
0
◎
Pr118
0
◎
Pr082
內控前八段速運轉方向
0~255(0:正轉1:反轉)
0
◎
Pr083
內控後八段速運轉方向
0~255(0:正轉1:反轉)
0
◎
Pr084
內控前八段速加減速時間
0~65535
0
◎
Pr085
內控後八段速加減速時間
0~65535
0
◎
Pr086
頻率二設定
0.00-400.00 Hz
15.00
◎
Pr087
低速運行時間
1~250s
60s
◎
Pr135
停機壓力准位
1~150%
95%
◎
Pr136
停機准位連續時間
1~250s
30s
◎
Pr137
喚醒准位
1~150%
80%
◎
Pr138
睡眠頻率
0.00~400.0
20.00
◎
Pr139
睡眠頻率連續時間
1~250s
20s
◎
Pr140
保留
Pr141
電機額定電壓
按馬達銘牌設定
過壓失速選擇
0:過壓失速防止功能無效
1:過壓失速防止功能有效
1
◎
Pr119
加速中失速准位元
0-200
150
◎
Pr120
恒速中失速准位
0-200
0
◎
Pr121
恒速中失速防止時減速時間
0.1-25.5
5
◎
Pr122
減速中失速防止准位
0-200
150
◎
Pr123
過轉矩檢測方式選擇
0~3
◎
Pr124
過轉矩檢測准位
內控多段速計時器二
0.0-6500.0S
10.0
◎
Pr103
內控多段速計時器三
0.0-6500.0S
0.0
◎
Pr104
內控多段速計時器四
0.0-6500.0S
0.0
◎
Pr105
內控多段速計時器五
0.0-6500.0S
0.0
◎
Pr106
內控多段速計時器六
0.0-6500.0S
0.0
◎
Pr107
內控多段速計時器七
0:STOP無效
1:STOP有效
1
○
Pr025
啟動方式
0:由啟動頻率開始起動
1:頻率跟
數
Pr026
停車方式
0:減速停止
1:自由運轉停止
0
◎
Pr027
啟動頻率
0.1~10.0 Hz
0.5
◎
Pr028
停車頻率
0.1~10.0 Hz
0.5
◎
Pr029
啟動制動時間
0~25.0
0.0
◎
基準頻率
0.01~400.00 Hz
50.00
◎
Pr005
最高操作頻率
10.00~400.00 Hz
50.00
◎
Pr006
中間頻率
0.01~400.00 Hz
2.5
◎
Pr007
最低頻率
0.01~20.00 Hz
0.50
◎
Pr008
最高電壓
0.1—220/380 V
根據機型而定
◎
Pr009
扭矩提升1
0.1~510.0V
第五章:功能參數一覽表
功能碼
名稱
參數詳細說明
出廠值
更改
說明
Pr000
參數鎖定
0:無效1:有效
0
○
主要功能方面
參
數
Pr001
控制方式
0:操作面板
1:外部端子
2:通訊口
0
◎
Pr002
頻率設定選擇
0:操作面板
1:面板電位器
2:外部端子
3:通訊口
0
◎
Pr003
主頻率
0.00~400.00 Hz
50.00
◎
Pr004
通訊位址
0-250
0
◎
4
8
5通
訊
功
能方面參數
Pr164
通訊傳送速度
0-3
1
◎
Pr165
通訊資料方式
0-5
0
◎
Pr166
保留
Pr167
Pr168
Pr169
保留
Pr170
顯示內容選擇
0-5
0
○
監
視
參
數
Pr171
顯示內容開啟
0-15
0
○
Pr172
故障清除
00 – 10(01為故障清除)
◎
Pr173
變頻器額定電壓
頻率八設定
0.00-400.00 Hz
0.50
◎
Pr093
頻率九設定
0.00-400.00 Hz
10.00
◎
Pr094
頻率十設定
0.00-400.00 Hz
15.00
◎
Pr095
頻率十一設定
0.00-400.00 Hz
20.00
◎
Pr096
頻率十二設定
0.00-400.00 Hz
25.00
◎
Pr097
03
◎
Pr053
J2端子輸出功能
00
◎
Pr054
FO輸出功能
數位頻率信號輸出端0-7
0
◎
Pr055
FO類比輸出增益
0.0~100.0%
100
◎
附加功能方面參數
Pr056