消防应急照明规范

合集下载

消防应急照明及疏散指示系统技术规范标准

消防应急照明及疏散指示系统技术规范标准

消防应急照明和分散指示系统技术规范1 总则为了合理设计消防应急照明和分散指示系统,提升消防应急照明和分散指示系统的施工质量,保证系统正常运转,保证在发生火灾时人员顺利逃生和消防作业,拟订本规范。

本规范合用于新建、改建、扩建、内装饰和改变使用性质的工业与民用建筑内设置的消防应急照明和分散指示系统的设计、施工、查收与保护;不合用于生产和存贮火药、炸药、弹药、火工品等有爆炸危险的场所。

消防应急照明和分散指示系统的设计,一定依据国家有关目标、政策,针对使用对象的特色,做到安全合用、技术先进、经济合理。

消防应急照明和分散指示系统的设计、施工、查收与保护,除切合本规范外尚应履行国家有关标准、规范规定。

2 术语消防应急照明和分散指示系统Fire emergency lighting system为人员分散和发生火灾时仍需正常工作的场所供给照明和分散指示的系统,由各种消防应急灯具及有关装置构成。

消防应急灯具Fire emergency luminaire为人员分散、消防作业供给照明和标记的各种灯具,包含消防应急照明灯具、消防应急标记灯具和消防应急照明标记灯具。

消防应急照明灯具Fire emergency lighting luminaire为人员分散、消防作业供给照明的消防应急灯具。

消防应急标记灯具Fire emergency indicating luminaire用图形和 / 或文字达成下述功能的消防应急灯具。

a)指示安全出口及其分散方向;b)指示楼层、逃难层及其余安全场所;c)指示禁止入内的通道、场所及危险品寄存处。

消防应急照明标志灯具Fire emergency lighting&indicating luminaire同时具备消防应急照明灯具和消防应急标记灯具功能的消防应急灯具。

自带电源型消防应急灯具Fire emergency luminaire powered by self contained battery电池、光源及有关电路装在灯具内部的消防应急灯具。

消防应急照明和疏散指示系统规范

消防应急照明和疏散指示系统规范
详细描述
根据规定,系统的照明亮度应符合国家相关标准,如《消防应急照明和疏散指示系统》中的规定。具体来说,系 统的照明亮度应能够在各种紧急情况下(如火灾、地震等)保持足够的亮度,以帮助人员识别逃生路线和指示标 志。此外,系统的亮度还应根据不同的使用场景和场所进行调整,以满足实际需要。
指示准确度要求
总结词
定期对指示标志进行检查,确保 其完好无损、清晰可见。
及时修复
如发现指示标志有损坏或模糊不 清的情况,应及时进行修复或更
换。
清洁保养
定期对指示标志进行清洁保养, 保持其整洁美观,提高疏散引导
效果。
04
CHAPTER
系统性能要求
照明亮度要求
总结词
照明亮度是消防应急照明和疏散指示系统的重要性能指标,要求系统在紧急情况下提供足够的亮度,确保人员能 够清晰地看到指示标志和逃生路线。
定制化与人性化
针对不同场所和人群的需求,消防应急照明和疏散指示系 统将趋向定制化和人性化,以满足不同场所的特殊要求和 使用体验。
THANKS
谢谢
定义与范围
定义
消防应急照明和疏散指示系统是在火 灾或其他紧急情况下,为人员提供照 明和疏散指示的设备系统。
范围
本规范适用于新建、改建和扩建的建 筑物中的消防应急照明和疏散指示系 统的设计、安装和维护。
02
CHAPTER
消防应急照明系统规范
照明灯具选择
01
02
03
照明灯具类型
应选择高效、低功耗的 LED灯具,具有较长的使 用寿命和稳定的照明性能。
消防应急照明和疏散指示系统 规范
目录
CONTENTS
• 引言 • 消防应急照明系统规范 • 消防疏散指示系统规范 • 系统性能要求 • 安全注意事项 • 结论

消防应急照明系统规范

消防应急照明系统规范

消防应急照明系统规范1. 简介本文档旨在规范消防应急照明系统的设计、安装、使用和维护,确保在紧急情况下提供有效的照明支持,保障人员安全撤离。

2. 设计要求2.1 灯具布置:应根据建筑物的功能、使用人数和布局进行灯具的布置设计,确保灯光覆盖范围和亮度符合安全标准要求。

灯具布置:应根据建筑物的功能、使用人数和布局进行灯具的布置设计,确保灯光覆盖范围和亮度符合安全标准要求。

2.2 电源备份:消防应急照明系统应与建筑物主电源相互独立,采用备用电源供电,以确保在主电源故障时能正常工作。

电源备份:消防应急照明系统应与建筑物主电源相互独立,采用备用电源供电,以确保在主电源故障时能正常工作。

2.3 自动转换:消防应急照明系统应具备自动转换功能,能够在主电源故障时自动切换到备用电源供电。

自动转换:消防应急照明系统应具备自动转换功能,能够在主电源故障时自动切换到备用电源供电。

3. 安装要求3.1 灯具安装:灯具应按照设计要求进行安装,并确保固定可靠、牢固不松动。

灯具安装:灯具应按照设计要求进行安装,并确保固定可靠、牢固不松动。

3.2 电源接线:应采用合适的电线规格进行电源接线,确保安全可靠,并避免线路过长、穿插干扰。

电源接线:应采用合适的电线规格进行电源接线,确保安全可靠,并避免线路过长、穿插干扰。

3.3 测试设备:应配备专业的测试设备,对消防应急照明系统进行定期检测、维护和保养,确保其正常工作状态。

测试设备:应配备专业的测试设备,对消防应急照明系统进行定期检测、维护和保养,确保其正常工作状态。

4. 使用与维护4.1 日常维护:应定期检查消防应急照明系统的灯具和电源设备是否正常工作,如有故障及时修复或更换。

日常维护:应定期检查消防应急照明系统的灯具和电源设备是否正常工作,如有故障及时修复或更换。

4.2 紧急情况演练:定期组织消防应急照明系统的紧急情况演练,提升人员对系统的熟悉度和应急处理能力。

紧急情况演练:定期组织消防应急照明系统的紧急情况演练,提升人员对系统的熟悉度和应急处理能力。

消防应急照明灯标准

消防应急照明灯标准

消防应急照明灯标准
消防应急照明灯是为人员疏散、消防作业提供照明的消防应急灯具,其标准通常包括以下几个方面:
1. 亮度要求:消防应急照明灯的亮度应该符合相关标准的要求,以确保在紧急情况下能够提供足够的照明。

2. 照明时间:消防应急照明灯的照明时间应该符合相关标准的要求,以确保在紧急情况下能够持续提供照明。

3. 电池寿命:消防应急照明灯的电池寿命应该符合相关标准的要求,以确保在紧急情况下能够正常使用。

4. 安装位置:消防应急照明灯的安装位置应该符合相关标准的要求,以确保在紧急情况下能够提供最佳的照明效果。

5. 标识要求:消防应急照明灯应该有明确的标识,包括型号、规格、生产日期等。

6. 质量要求:消防应急照明灯的质量应该符合相关标准的要求,以确保其能够在紧急情况下正常使用。

消防应急照明灯的标准制定是为了保证其质量和可靠性,确保其能够满足消防应急照明的要求。

在进行消防应急照明灯的选择和使用时,应该严格按照相关标准进行,以确保其能够在紧急情况下发挥作用。

消防应急照明和疏散指示系统的设置规范

消防应急照明和疏散指示系统的设置规范

消防应急照明和疏散指示系统的设置规范在我们的生活中,消防应急照明和疏散指示系统是不可或缺的一部分。

这些系统不仅仅是冷冰冰的设备,它们承载着生命的重托。

在紧急情况下,它们能引导我们安全撤离,避免人身伤害。

想象一下,当火灾发生时,浓烟弥漫,四周漆黑一片,只有那闪烁的指示灯像灯塔一样指引着我们前行。

首先,咱们得聊聊系统的设置。

根据规范,消防应急照明系统的设置得讲究。

首先是照明的亮度和覆盖范围,必须确保每个出口和疏散通道都能清晰可见。

这个亮度可不是随便的,太暗容易迷路,太亮又刺眼。

合理的设计就像做菜,火候要掌握得当。

然后,咱们得提到指示标志的颜色。

红色标志给人紧迫感,容易让人反应过来。

而绿色指示则让人感到安全,像是一条宽广的路。

两者结合,就能让人在关键时刻迅速找到出路。

它们的设置位置也要巧妙,不可以遮挡。

试想一下,如果指示灯被家具挡住,那可真是雪上加霜。

接下来,咱们谈谈系统的维护。

消防应急照明和疏散指示系统可不能光靠设置。

定期的检查和维护是必不可少的。

就像汽车得保养,设备也要定期“体检”。

这样才能确保在关键时刻,它们能够发挥出应有的作用。

想象一下,如果突然停电,灯不亮了,那可真是危机四伏。

再来,我们不得不说一下培训的重要性。

无论是工作人员还是普通居民,都应该了解这些系统的功能和使用方法。

培训可以让大家在危急关头不慌张。

比如,在火灾演练中,大家都知道如何迅速找到出口,减少恐慌。

那种安心感,真是无价。

最后,咱们要强调一点,系统的设计和设置要人性化。

尤其是在大型场所,比如商场和医院,人员流动性大,容易出现混乱。

这时候,系统就要像一位温柔的引导者,轻声告诉大家该往哪走。

只有做到这一点,才能真正保障每一个人的安全。

总的来说,消防应急照明和疏散指示系统的设置,不仅仅是遵循规范,更是关乎生命的责任。

希望每个人都能重视这些细节,让我们的生活更加安全。

《消防应急照明和疏散指示系统技术规范》 GB 51309-2018

《消防应急照明和疏散指示系统技术规范》 GB 51309-2018
UDC
P
中华人民共和国国家标准
GB 51309 – 2018
消防应急照明和疏散指示系统技术标准
Technical Standard for fire emergency lighting and evacuate indicating system
2018– 07 –01 发布
2019 – 03 –01 实施
4 3.1 一般规定····················································································· 5 3.2 灯具······························································································· 12 3.3 系统配电的设计············································································· 3.4 应急照明控制器及集中控制型系统通信线路的设计······································17 19 3.5 系统线路的选择················································································ 3.6 集中控制型系统的控制设计··································································20 3.7 非集中控制型系统的控制设计·······························································25 26 3.8 备用照明设计··················································································· 4 施工 28 ································································································ 28 4.1 一般规定····················································································· 30 4.2 材料、设备进场检查·········································································· 30 4.3 布线····························································································· 4.4 应急照明控制器、集中电源、应急照明配电箱安装········································32 34 4.5 灯具安装························································································· 5 系统调试 37 ··························································································· 37 5.1 一般规定····················································································· 38 5.2 调试准备························································································ 5.3 应急照明控制器、集中电源和应急照明配电箱的调试·····································39 5.4 集中控制型系统的系统功能调试·····························································41 5.5 非集中控制型系统的系统功能调试··························································44 46 5.6 备用照明功能调试············································································· 6 系统检测与验收 47 ·················································································· 7 系统运行维护 51 ····················································································· 附录 A 消防应急照明和疏散指示系统子分部、

消防应急照明和疏散指示系统施工及安装规范

消防应急照明和疏散指示系统施工及安装规范

消防应急照明和疏散指示系统施工及安装规范消防应急照明和疏散指示系统的施工和安装规范施工1.主要设备规定1)智能疏散系统中使用的灯具、应急照明集中电源和应急照明控制器等产品必须是通过国家型式认可(或认证)的产品。

产品的名称、型号、规格、使用电池应与市场准入制度要求的有效证明文件一致。

检验方法为核对认可(或认证)证书与产品标志、名称、型号、规格是否相符;核对检验报告(有产品照片)与产品外观是否相符。

检查数量为每个批次、每个规格各抽一台。

2)自带电源型消防应急灯具应抽查应急工作时间和状态转换功能,其应急工作时间不应小于其标称的应急工作时间。

状态转换和状态指示应正常。

检验方法为充电24小时后放电,期间观察灯具的状态转换和状态指示,测量放电时间。

检查数量为每个批次、每个规格各抽一台。

3)疏散指示牌应是通过国家消防产品质检中心检验合格产品。

产品名称、型号、规格应与检验报告一致。

检查方法为核对检验报告(有产品照片)与产品外观是否相符。

施工前,必须准备好系统图、设备布置平面图、接线图、安装图以及消防联动逻辑说明等必要的技术文件。

在施工过程中,施工单位应做好施工(包括隐蔽工程验收)、检验、调试、设计变更等相关记录。

施工结束后,施工方应对系统的安装质量进行全数检查。

竣工时,施工单位应完成竣工图及竣工报告。

2.安装1)系统的安装应符合国家标准GB《建筑电气工程施工质量验收规范》要求。

2)消防应急灯具与供电线路之间的连接不得使用插头连接。

3)消防应急灯具安装后不应对人员正常通行产生影响。

消防应急疏散指示标志灯周围应保证无其他遮挡物,消防应急灯具不应安装在可燃材料表面上。

4)带有疏散方向指示箭头的消防应急疏散指示标志灯在安装时应保证箭头指示疏散方向的与疏散方向相同。

5)指示出口的消防应急标志灯应固定在坚固的墙上或顶棚下,安装方式可以明装,也可以嵌墙暗装。

6)消防应急灯具在安装时应保证灯具上的各种状态指示灯易于观察,试验按钮(开关)能被人工或遥控操作。

消防应急灯安装位置及安装规范

消防应急灯安装位置及安装规范

消防应急灯安装位置及安装规范消防应急照明灯安装位置:根据《建筑设计防火规范》及《高层民用建筑设计防火规范》的规定,消防应急照明灯具的安装位置应该在建筑物的下列部位;1.封闭的楼梯间、防烟楼梯间及其前室,消防电梯及其前室;2.配电室、消防控制室、自动发电机房,消防水泵房、防烟排烟控制室,供消防用电的蓄电池室,电话总机房以及在发生火灾时任然需要停留在火灾环境中进行扑灭火情的其他房间;3.观众厅每层超过1500㎡的展览厅、营业厅、建筑面积超过2000㎡的演播室,人员密集且建筑面积超过300㎡的地下室等;4.公共建筑内的疏散走道(安全出口通道)和长度超过20米的内走道等;消防应急灯安装位置参考图例消防应急灯安装规范一、消防应急照明灯安装规范常见的双头消防应急照明灯,一般安装于疏散通道大门出口的门框上方,走廊、安全出口走道的墙壁上,距离地面约2米以上的高度;大型的电子市场、购物中心等场所,双头应急灯有直接壁挂安装于立柱上面的。

消防应急灯的安装位置以不被物体撞击,遮挡为好;安装过高,会影响停电应急时光照亮度的光效作用,及对应急灯具进行检修、调试的不便;双头消防应急照明灯的按照高度以2.2米左右即可;也要根据使用场所的实际情况而定,当使用场所的空间较大,应急灯具的使用密度增加的情况下,可以适当的对安装高度进行调整;前提条件必须满足消防检查验收部门的相关规定;双头应急灯酒店房间安装图例消防应急照明灯酒店走廊安装使用图例led 应急吸顶灯安全走道安装使用效果图二、消防应急安全出口指示灯的安装规范消防应急出口灯可分为安全出口标志灯和疏散通道指示标志灯。

安全出口标志灯的安装位置通常在建筑物内通往室外的正常出口和应急通道的出口处。

多层和高层建筑各楼层通往楼梯间和消防电梯前室的门口;大面积的厅堂、场、馆通向疏散通道和通往前厅、侧厅、楼梯间的出口;消防应急疏散指示灯安装位置图例安全出口灯一般安装于出口门框的上方,如果门框太高时,可安装于门框的侧口位置;为防止火灾发生时产生的烟雾影响视觉,其安装高度以2.2-2.5米为宜;安全出口灯安装位置图例消防安全指示灯的安装位置通常是在公共建筑物内的安全疏散通道,方便人员疏散时,无论从哪个位置都能够找到正确的紧急逃生出口,消防应急疏散通道或安全紧急出口通道安装的应急疏散指示灯间距不应大于20米。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

消防应急照明规范
消防应急照明是指在火灾等突发情况下,为人员提供必要的照明照度,保证人员疏散安全的一种特殊照明照明。

下面是消防应急照明规范的主要内容。

1. 照明设备的选择:应选择可靠性高的照明设备,如应急灯具、疏散指示灯等,确保其正常工作和长时间使用。

应急照明设备应具备防水、防爆、防尘等功能。

2. 安装位置和数量:应急照明设备应安装在容易发生火灾的区域,如走廊、楼梯间、安全出口等。

照明设备的数量要根据建筑物的大小和人员密度来确定,保证人员在火灾发生时能够迅速找到应急照明设备。

3. 照明照度要求:照明设备应保证照度达到规定的要求,一般是10流明/平方米。

在疏散通道上,夜间的照度应不低于5流
明/平方米,以确保人员能够清晰看到前方和疏散通道的走向。

4. 照明时长要求:消防应急照明设备应能够保证连续工作2小时以上,以应对火灾疏散过程中可能出现的电力中断等情况。

应急照明设备的备用电源应进行定期检查和维护,确保其正常工作。

5. 照明指示标志:疏散通道和安全出口应安装照明指示标志,以指示人员正确的疏散方向。

照明指示标志应清晰可见,具备发光和反射功能,即使在电力中断的情况下,人员也能够看到指示标志。

6. 照明设备的检查和维护:应定期对消防应急照明设备进行检查和维护,确保其正常工作。

检查内容包括电池的充电情况、灯具的照度和照射方向、指示标志的亮度等。

发现问题应及时修复或更换设备。

7. 培训和演练:对建筑物的管理人员和相关人员进行消防应急照明设备的使用培训和疏散演练,提高人员的应急意识和疏散能力。

培训内容包括照明设备的位置和使用方法、疏散通道的选择和疏散顺序等。

以上是消防应急照明规范的一些主要内容,对于保障人员的生命安全和疏散效率具有重要意义。

消防应急照明规范的制定和执行是建筑物安全管理的重要环节,建筑物的相关人员应密切配合,确保规范的有效实施。