优质饮用水的消毒方法

优质饮用水的消毒方法
优质饮用水的消毒方法

优质饮用水的消毒方法

王宝贞1,王欣泽1,李 冰2,张广群1

(1.哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090;2.大庆油田设计研究院,黑龙江大庆163712)

摘 要:饮用水中常见的消毒工艺包括液氯、氯胺、二氧化氯、臭氧、紫外线和膜消毒等.分析了各种消毒工

艺的机理、运行特点和对各种病原微生物的处理效率.饮用水深度净化工艺能够很好地去除水中消毒副产

物前驱物质及病原微生物,提出以氯胺或二氧化氯作为最终的消毒剂,而臭氧氧化可以作为预处理的处理方

案.分析了紫外线消毒技术的应用范围.

关键词:消毒;深度净化;饮用水

中图分类号:T U991.25 文献标识码:A 文章编号:036726234(2002)0420478205

Disinfection of high quality drinking w ater

W ANG Bao2zhen1,W ANG X in2ze1,LI Bing2,ZH ANG G uang2qun1

(1.School of Municipal and Environmental Engineering,Harbin institute of technology,Harbin150090,China;2.Daqing Oil Field Design and Research Institute,Daqing163712,China)

Abstract:The comm on disin fecting process of drinking water includes free chlorine,chloramine,chlorine dioxide, ozone,UV and membrane etc.The disin fection mechanism,operation characteristic and pathogenetic microorgan2 isms rem oval efficiency of each disin fection process was discussed.With advanced drinking water treatment technol2 ogy the disin fecting by2products formation potential and pathogenetic microorganisms can be effectively rem oved.It was recommended that chloramine or chlorine dioxide is used as final disin fectants and ozone oxidation as pretreat2 ment.The application range of UV disin fection technology was als o discussed.

K ey w ords:disin fection;advanced treatment;drinking water

随着人们生活水平的提高和水处理工艺的发展,传统的混凝沉淀砂滤工艺已不能满足人们的要求,饮用水深度净化工艺在国内外得到了广泛的研究和应用.在发达国家,市政自来水的水质是以满足直接饮用为目标的,而在我国,管道直饮水技术指对市政自来水进行深度处理,采用单独的供水管道供给用户,满足生饮需要.目前在一些经济较为发达城市的新建小区中,已逐步开始建立饮用水深度净化工程.

水质标准的提高对消毒工艺提出了挑战,在

收稿日期:2002-01-09.

基金项目:“九五”国家科技攻关项目(96-9090003-03).

作者简介:王宝贞(1932-),男,教授,博士生导师.美国总大肠杆菌标准(T otal C oliform Rule)中提出了对去除水中大肠杆菌的更为严格的标准和更为严格的检测手段,而另一方面消毒剂和消毒副产物标准(Disin fectantsΠDisin fection By-product Rules)却严格地限制了水中消毒剂和消毒副产物的最大值,这使得微生物的灭活要求又难以满足,尤其是近年来研究较多的对人们的健康构成较大威胁的贾第虫和隐孢子虫的灭活要求难以满足[1].当前水源水质恶化主要是以有机污染为主[2],水中的有机物质通过常规的混凝-沉淀-砂滤工艺难以达到非常理想的处理效果.许多天然有机物质如腐殖质,能够与消毒剂Cl

2

发生化学反应,形成消毒副产物.在饮用水深度净化工艺中,采用合理的消毒方法,在保证去除致病菌的

第34卷 第4期 哈 尔 滨 工 业 大 学 学 报 V ol.34 N o.4 2002年8月 JOURNA L OF H ARBI N I NSTIT UTE OF TECH NO LOGY Aug.,2002

同时,又最大限度的减少消毒副产物的浓度是本文研究的主要内容.

1 常见各种消毒方法研究

1.1 氯消毒和氯胺消毒

氯消毒目前仍然得到最广泛的应用,人们对其消毒机理进行了较多的研究.氯消毒主要是通过次氯酸的氧化作用来杀灭细菌,对于水中的病毒、寄生虫卵的杀灭效果较差,需要在较高CT值(消毒剂浓度乘以接触时间)才能达到理想的除菌效果.用氯消毒的另外一个主要的问题就是活性氯与水中的有机物反应生成消毒副产物,其中以三氯甲烷和卤代乙酸为代表.当原水中含有较多的天然有机物如腐殖酸等时,氯消毒后水消毒副产物的含量会超过净水标准.另外,采用氯消毒的口感比采用其他消毒剂差.

氯胺消毒的机理一般认为与氯消毒相同.由于采用氯胺消毒能够减少消毒过程中的TH Ms的产生,并且氯胺在管网中的持续时间更长,所以近年来许多水厂由氯消毒改用氯胺消毒.而且采用氯胺消毒也缓解自来水中的氯味问题[3].氯胺在控制管网中细菌的再次繁殖和生物膜也比氯更为有效[4].

然而氯胺和氯消毒对水中的贾第虫和隐孢子囊的去除效果却不能够令人满意.如在pH=6~9,水中的贾第虫灭活效率达到99.9%时,氯胺的CT值需高达2200mg?minΠL,而对隐孢子在pH7,温度为25℃时,采用氯消毒只有CT值高达7200 mg?minΠL时才能够达到99%的去除率,而在实际应用中难以达到这样高的CT值[5].

1.2 二氧化氯消毒

二氧化氯是由汉费莱?戴维于1811年发现的.二氧化氯是一种强氧化剂,对细菌的细胞壁有较好的吸附和穿透性能,可以有效地氧化细胞酶系统,快速地控制细胞酶蛋白的合成,因此在同样条件下,对大多数细菌表现出比氯更高的去除效率,如在pH=8.5,投药量0.25mgΠL和接触时间为15s的情况下,就能够对水中的大肠杆菌达到99%的去除效果[6].而且二氧化氯对水中的隐孢子虫有着很好的去除效果,处理效率远好于氯但弱于臭氧,关于采用二氧化氯杀灭隐孢子囊的试验人们进行了很多,在pH=8,温度为20℃条件下,处理效率达到90%时的CT值为50~70mg ?minΠL,而处理效率达到99%时的CT值为100~130mg?minΠL[7,8].

单纯的二氧化氯消毒,不会形成显著的含氯的有机消毒副产物,形成的三卤甲烷和卤代乙酸的质量浓度分别低于1和10μgΠL.但是目前国内生产二氧化氯的方法主要有电解法和化学法,这两种方法都会含有一定量的自由氯,在化学法中产生的二氧化氯的量约为总有效氯质量分数的68%,而电解法产生的二氧化氯的质量分数仅为30%左右,所以采用二氧化氯消毒仍然存在着产生含氯有机消毒副产物的可能,只是浓度比液氯消毒低得多.

二氧化氯消毒所产生的主要的消毒副产物为亚氯酸盐和氯酸盐.它们对人体健康有潜在的危害,世界卫生组织对亚氯酸盐在水溶液中的质量浓度建议控制在200μgΠL以下,而对氯酸盐的毒性还在进一步的研究之中[9].

1.3 臭氧消毒

臭氧作为消毒剂应用于本世纪初.臭氧一经溶解在水中,会出现下列两种反应:一种是直接氧化,它是较缓慢的且有明显选择性的反应;另一种则是在水中羟基、过氧化氢、有机物、腐植质和高浓度的氢氧根诱发下分解成羟基自由基,间接地氧化有机物、微生物和氨等.后一种反应相当快,且没有选择性[10].由于具有很高的氧化电位和容易通过微生物细胞膜扩散,并能氧化微生物细胞的有机物或破坏有机体链状结构而导致细胞死亡,对一些顽强的微生物如病毒、芽孢等有强大的杀伤力.

臭氧是目前已知的化学消毒剂中最为有效的一种消毒剂.对水中的各种微生物都表现出良好的去除效果.如在室温条件下,CT值为3和8mg ?minΠL时就可以对水中的隐孢子分别达到2倍和3倍的对数去除率[11].

在臭氧消毒产生的消毒副产物中,有机的消毒副产物以甲醛为代表,无机的副产物主要是溴酸根离子.WH O(1996)饮用水水质指标中甲醛为900μgΠL,溴酸根25μgΠL[12].目前人们研究的热点主要集中在如何能够在有效的灭活水中的致病菌同时又能够控制溴酸根在允许的浓度范围之内[13,14].

臭氧消毒工艺的优点比较明显,对致病菌尤其是耐氯的隐孢子和贾第虫的在低投加量的情况下就能够达到很好的杀灭效果,消毒后水的口感明显好于氯消毒水.臭氧消毒所要解决的主要问题是消毒副产物的控制问题,臭氧的生产设备庞大,流程复杂,需要较高的运行管理水平,同时臭氧容易分解,在室温下,水中的臭氧的半衰期约为30min,在输送管道较长时,单独采用臭氧消毒难

?

9

7

4

?

 第4期 王宝贞,等:优质饮用水的消毒方法

以保证持续的杀菌效果,容易产生细菌的增值问题.臭氧消毒也是各种消毒工艺中造价较高的. 1.4 紫外线消毒

近年来,紫外线技术得到了迅速的发展.在欧洲已经有2000多座饮用水处理厂采用紫外线消毒技术[15].紫外线指的是波长在100~400nm 的电磁波,而在消毒工艺中更有意义的波长为250~270nm,这也正是常用的低压汞灯所辐射的紫外线的主要波长范围,占全部能量输出的85%以上.在波长为254nm附近,两种重要的遗传物质DNA和RNA有强烈的吸收,紫外线能够改变DNA和RNA内含氮的杂环物质,如胸腺嘧啶,在相邻的核苷之间产生新键,形成二聚物,这种作用导致微生物不能进行自我复制,达到了消毒的目的.

对细菌灭活需要的紫外线剂量以紫外线的强度乘以辐照时间计算,它必须保证DNA不能进行自我复制或者突变后代不能进行自我复制[16].一般细菌的体积越大或者DNA和RNA数目越多,对其灭活所需的紫外线剂量就越大.而水中的病毒和成孢细菌对紫外线的抵抗能力也要比其他的细菌高;病毒本身对紫外线的抵抗能力很弱,但是通过宿主的保护作用增强了病毒耐紫外线性.病毒、细菌孢子和变形虫若想获得与大肠杆菌同样的处理效率,其紫外线消毒剂量分别是大肠杆菌的3、4、9和15倍[17].与其他消毒方法不同,采用不同的检测方法,所获得的紫外线消毒效果也不一样.如紫外线杀灭贾地鞭毛虫的试验中,用动物感染所测的的紫外线杀菌效果,要远好于采用体外脱囊(in vitro excystation)方法测得的效果[18].而在紫外线杀灭隐孢子囊的试验中也有类似的结果[19].

对于水中的绝大多数的微生物来说,当紫外线的辐照剂量大于40mW?sΠcm2时,就可以取得大于3的对数去除率(或99.9%的去除率).各国对紫外线消毒的辐照剂量标准各不相同.美国国家标准局和国家卫生基金会标准55-1991(ANSIΠNSF Standard55-1991)中规定了两种标准,对于过滤后的地表水,最小辐照剂量为38mW?sΠcm2,作为其他消毒处理补充的最小辐照剂量为16mW ?sΠcm2.挪威和奥地利规定的最小辐照剂量为16和30mW?sΠcm2.而其他的一些规定中并不指定处理方法,主要是通过控制微生物的最大浓度要求消毒工艺.在实际水处理中,紫外线的消毒剂量大多为40~140mW?sΠcm2,而且主要由制造商来控制.

紫外线消毒技术的优点比较明显,在小水量时有明显的经济优势,在很低的消毒剂量和很短的停留时间的条件下,就能够有效的杀灭致病菌,而且其中有一些致病菌是液氯消毒难以灭活的[20].许多市售的饮用水消毒器都能够对水中的病毒达到4倍以上的对数去除率.紫外线消毒设备易于安装,运行和管理都非常方便.更重要的一点紫外线处理作为一种物理处理方法,不向水中添加新的物质,消毒后的水中不会产生消毒副产物,这也正是化学消毒方法难以解决的一个问题.

紫外线消毒所面临的主要问题就是消毒后的水中无“余氯”作用,在管网内细菌容易重新繁殖,所以单纯的紫外线消毒一般用于小水量,处理后水立刻就被使用的情况,或者原水的生物稳定性好,有机物质量分数极低(一般在10μgΠL以下),而且配水管网内不存在二次污染的情况.

1.5 膜消毒

膜技术被称为21世纪的技术,在饮用水处理工艺中主要应用的压力驱动膜根据孔径的尺寸可以分为微滤、超滤、纳滤和反渗透.膜过滤在水处理中不仅作为去除细菌的有效手段,同时也是去除其他污染物质的重要工艺.在英国最新的有关隐孢子虫的标准(Cryptosporidium Regulation)中,不允许紫外线或臭氧单独作为去除隐孢子虫的手段,新的要求规定处理工艺必须采用能够去除尺寸大于1μm的颗粒的物理屏障,这可能是世界上坚持采用膜工艺的最严格的要求.

与其他消毒方法相比,膜消毒不是将细菌杀死,而是将细菌从水中隔离出来,这样也防止了水中的死细菌再次成为热源.如果仅仅从去除水中细菌的角度出发,采用低压膜超滤和微滤工艺就可以得到理想的效果.超滤膜孔径为5~20nm,微滤膜的孔径为20nm~1μm[21].水中的细菌(0. 5~10μm)、隐孢子虫(4~6μm)和贾第虫(7~14μm)的尺寸大部分大于微滤和超滤的孔径范围.病毒的尺寸(0.01~0.025μm)则与超滤的孔径尺寸相仿.膜过滤工艺去除细菌的主要机理有物理筛分截留,膜表面或内部结构的吸附,膜表面形成的滤饼的截留作用.通过以上作用,膜对水中的各种粒子都表现出良好的效果.微滤和超滤对耐氯性强微生物如隐孢子和贾第虫都表现出其他化学药剂无法达到的效果.在滤出液中这种致病微生物的质量浓度都在检测限以下[22].而对水中病毒的去除,超滤则明显优于微滤,在采用截留相对分子质量‘为10000的超滤膜去除病毒的试验

?

8

4

?哈 尔 滨 工 业 大 学 学 报 第34卷 

中,其对数去除率也可以达到6以上[23].

采用膜消毒的优越性主要有:处理后的水质优良,不需要消耗化学药剂或仅需很少量的化学药剂,低能耗,低运行费用,消毒效果不受原水水质影响,出水水质稳定,等等.膜消毒所面临的主要问题有:膜的堵塞问题,膜的完整性破坏后,滤后水质变坏问题等[24].

1.6 复合消毒方法

由于每一种消毒方法都有一定的局限性,于是人们提出了复合消毒的方法,即采用臭氧或紫外线作为第一步的消毒工艺,有效的杀灭水中的各种病原微生物,再投加二氧化氯、液氯或氯胺等不易分解的消毒剂来维持持续消毒效果[25,26].人们对于采用臭氧预处理然后采用氯或氯胺进行消毒的工艺进行了较多的研究,通过协同作用,取得了较好的效果,尤其是水中的贾第虫等需要较高CT值灭活病原微生物[27].

2 优质饮用水对消毒工艺的要求饮用水深度净化的目的是进一步提高水质,去除水中的有害物质.自来水经过常规的水厂处理后,水中的有害物质主要是消毒副产物和消毒副产物前驱物质.1996年,美国国家环保局(USE2 PA)对美国493个饮用水处理厂去除消毒副产物前驱物质进行了可行性研究,而推荐的工艺主要是活性炭吸附和膜过滤工艺[28].我国目前饮用水深度净化采用工艺也是以这两种工艺为主[29~32].从深度净化的工艺特点分析,活性炭吸附和膜过滤技术都能够有效地去除水中的以T OC为代表的消毒副产物前驱物质和其他的有害物质.根据笔者在北京燕山地区进行的试验表明,活性炭过滤能够有效地去除水中的有机物质,使高锰酸钾指数从2.0mgΠL降低到1.2~1.3mgΠL,而TH M2 FP也可以从124μgΠL降低到75μgΠL左右.通过超滤膜工艺则能够进一步的提高水质,出水中的细菌和大肠杆菌均在检测限以下,而对需要较高CT值处理的病原微生物也能够完全截留.纳滤膜和反渗透膜则能够进一步的去除水中的有机物质.所以,饮用水深度净化消毒工艺的主要目标应该是维持一定的管道中的消毒剂浓度,防止细菌的二次繁殖.

3 优质饮用水消毒方法的选择目前我国的大多数饮用水深度净化车间都采用臭氧消毒,存在的主要的问题就是臭氧分解很快,无法维持持续的杀菌效果,而且输送管道必须采用造价很高的耐臭氧腐蚀的管道.为了克服臭氧的分解问题,有的工艺采用了循环处理后水,重新加入消毒剂的办法,循环的水量达到了设计水量的50%[32],这样必然增加了系统的运行费用,而且从循环管路到用户之间仍然存在着死水区,用户很难控制如何取水,仍然存在着污染的可能性.

在较大规模的小区,建议在饮用水深度净化中对采用氯胺或二氧化氯作为最终的消毒工艺进行研究.一方面,在原水经过了深度净化之后,消毒副产物前驱物质的浓度很低,需要投加的消毒剂剂量较低.氯胺和二氧化氯消毒完全可以将生成的卤代有机物的浓度控制在极低的水平,而在去除了CT值很高的致病菌的前提下,氯胺和二氧化氯消毒能够满足控制微生物污染的水平.另一方面,氯胺和二氧化氯的分解很慢,能够维持持续的杀菌效果,可以不用设计循环管路.再者,氯胺和二氧化氯消毒的造价要比臭氧消毒低得多.关于嗅味,氯胺和二氧化氯同样可以避免液氯消毒的氯味问题.

臭氧在饮用水深度净化中作为前处理应用较多,不但可以消毒,还能够辅助去除水中的各种有机污染物质和铁锰等.

在一些小型的处理工艺中,在即取即用的情况下,可以考虑采用紫外线消毒,既可以保证供水的安全性,同时占地最少,是消毒工艺中较为经济的一种选择.

参考文献:

[1]Y OO S R.Microfiltration:A case study[J].J AWW A,

1995,87(5):38249.

[2]崔玉川,傅 涛.我国城市给水现状及特点[J].中国

给水排水,1999,15(2):52254.

[3]许保玖,安鼎年.给水处理理论与设计[M].北京:中

国建筑工业出版社,1992.

[4]C LE ME NT J A.Overview of American disin fectant residual

practice[J].J Wat SRT-Aqua,1999,48(2):59263. [5]C LARK R M,ADAMS J Q.C ontrol of microbial contamina2

nts and disin fection by2product for drinking wat in the US: cost and performance[J].J Wat SRT-Aqua,1998,47

(6):2552265.

[6]罗启达,王海亮,姜庆云,等.水处理中二氧化氯的

应用[J].城市公用事业,1999,13(4):22224.

[7]ARORA H,LECHE VA LLIER M,BATTIGE LLI D.E ffec2

tiveness of chlorine dioxide in treatment and disin fection by products rules[J].J Wat Supply:Res T echnol-AQUA, 2001,50(4):2092227.

[8]RUFFE LL K M,RE NNECKER J L,M ARI NAS B J.Inacti2

?

1

8

4

?

 第4期 王宝贞,等:优质饮用水的消毒方法

vation of cryptosporidium parvum oocysts withΠchlorine diox2 ide[J].Water Res,2000,34(3):8682876.

[9]MI NE AR R A,AMY GL.Disin fection By Products in Water

T reatment2the Chemistry of their F ormation and C ontrol[M].

New Y ork:CRC Press Inc,1996.3932395.

[10]王宝贞.水污染控制工程[M].北京:高等教育出版

社,1990.

[11]K AN JO Y,KI M AT A L.Inactivation of crytposporidium

spp.O ocysts with ozone and ultraviolet irradiation evaluat2 ed by in vitro excystation and animal in fectivity[J].Wat Sci T echnol,2000,41(7):1192125.

[12]周 云,梅 胜.给水处理中的臭氧副产物[J].中

国给水排水,1999,15(2):27228.

[13]G UNTER U V,PI NKERNE LL U.Ozonation of bromide2

containing drinking waters:a delicate balance between dis2 in fection and bromate formation[J].Wat Sci T echnol, 2000,41(7):53259.

[14]AMY G,DOUVI LLE C.Bromate formation under ozonation

conditions to inactivate cryptosporidium[J].Wat Sci T echn2 ol,2000,41(7):61267.

[15]沈 健.高纯水与紫外线技术[J].给水排水,1998,

24(12):40243.

[16]PARROTT A M J,BEK DASH F.UV disin fection of small

groundwater supplies[J].J AWW A,1998,90(2):71281.

[17]CH ANG J C,OSS OFF S F.UV inactivation of pathogenic

and indicator microorganism[J].Appl Envir Microbiol, 1985,49(6):136121365.

[18]CRAIK S A,FI NCH G R,BO LT ON J R,et al.Inactiva2

tion of giardia muris cysts using medium2pressure ultraviolet radiation in filtered drinking water[J].Wat Res,2000,34

(18):432524332.

[19]LI NDE N K G,SHI N G,S O LSEYM D.C omparative effec2

tiveness of UV wavelengths for the inactivation of Cryptospo2 ridium parvum oocysts in water[J].Wat Sci T echnol, 2001,43(12):1712174.

[20]C LANCYJ L,H ARGY T M.UV light inactivation of cryp2

tosporidium oocyst[J].J AWW A,1998,90(9):922102.[21]OS ADA Y,NAK AG AW A T.Membrane Science and T ech2

nology[M].New Y ork:M2Dekker,1992.

[22]JAC ANGE LO J G,LAI NE J M.Low pressure membrane

filtration for rem oving giardia and microbial indiacators[J].

J AWW A,1991,9:972106.

[23]JAC ANGE LO J G,ADH AM S S.Mechanism of cryptospo2

ridium giardia and MS2virus rem oval by MF and UF[J].J AWW A,1995,(9):1072121.

[24]M ADUE NI S S.The application research of membrane tech2

nology for water disin fection[J].Wat Res,1999,33(2): 3012308.

[25]DRIE DGER A M,RE NNECKER J L,M ARI NAS B J.In2

activation of Cryptosporidium parvum oocysts with ozone and m onochloramine at low temperature[J].Wat Res,2001, 35(1):41248.

[26]M AG ARA Y,S AS AKI T,K OZ AS A H,et al.C omparative

study of disin fectants for water supply[J].Wat Supply, 1996,14(3):3812386.

[27]RNNECKER J L,DRIE DGER A M.Synergy of Sequential

Inactivation of Cryptosporidium Parvum with OzoneΠFree chlorine and OzoneΠM onochloramine[J].Wat Res,2000, 34(17):412124130.

[28]A LLGEIER S C,SH UK AIRY H M,WESTRICKJ J.ICR

treatment studies utilities are currently evaluating mem2 branes and G AC for DBP pescus or rem oval[J].J AWW A, 1998,90:71282.

[29]刘起香,陈 华.深圳市梅林一村管道直饮水设计体

会[J].中国给水排水,2000,16(3):31233.

[30]沙爱燕.优质饮用水工程势在必行[J].环境保护科

学,1999,25(3):22224.

[31]马文铁.大庆油田分质供水工程规划及设计[J].给

水排水,2000,26(10):19221.

[32]李 云,李 冬.我国的“管道分质供水”现状[J].中

国给水排水,1999,15(1):24225.

(编辑 杨 波)

?

2

8

4

?哈 尔 滨 工 业 大 学 学 报 第34卷 

灾区生活饮用水消毒方法(2019年版)

自然灾害灾区生活饮用水消毒方法 (2019年版) 为保证灾区民众能够得到安全的生活饮用水,须做好生活饮用水水源地的保护,水质的消毒处理以及水质的检验。 B.1饮用水的处理与消毒 煮沸是最简单有效的消毒方式,在有燃料的地方可采用。煮沸消毒的同时可杀灭寄生虫卵,所有饮用水提倡煮沸后饮用。 根据水源水状况,选择适宜的化学消毒剂,在专业人员的指导下,参阅消毒剂使用说明书,控制消毒剂用量和接触时间。 B.1.1缸(桶)水消毒处理 自然灾害发生后,若取回的水较清澈,可直接消毒处理后使用。若很混浊,可经自然澄清或用明矾混凝沉淀后再进行消毒。常用的消毒剂为漂白精片或泡腾片。按有效氯4-8mg/L投药,先将漂粉精片或泡腾片压碎放入碗中,加水搅拌至溶解,然后取该上清液倒入缸(桶)中,不断搅动使之与水混合均匀,盖上缸(桶)盖,30min后测余氯0.3-0.5mg/L即可。若余氯达不到,则应增加消毒剂量,缸(桶)要经常清洗。 B.1.2手压井的消毒

手压井一般只经过消毒处理,水质即可达到生活饮用水卫生标准的基本要求。消毒方法同缸(桶)水消毒处理。 B.1.3大口井的消毒 B.1.3.1直接投加法 投消毒剂前先测量井水量及计算投药剂量,水井一般为圆筒状,即 井水量(t)=井水深(m)×3.14×[水井半径(m)]2 漂白粉的投加量(g)=漂白粉有效氯含量%(井水量(吨)×加氯量(mg/L)) 加氯量应是井水需氯量与余氯之和,可根据井水水质按一般清洁井水的加氯量为2mg/L,水质较浑浊时增加到3-5mg/L,以保证井水余氯在加氯30min后在0.7mg/L左右,有条件的地区可进行水质细菌学检验。 投加的方法是根据所需投药量,放入容器中,加水调成浓溶液,澄清后将上清液倒入水桶中,加水稀释后倒入水井,用水桶将井水震荡数次,使之与水混匀,待30min后即可使用。井水的投药消毒至少每天2次,即在早晨和傍晚集中取水时段前进行。 B.1.3.2持续消毒法 将漂白粉或漂粉精片装入开有若干个小孔(孔径为0.2-0.5cm,小孔数可视水中余氯量调整)的饮料瓶中(每瓶装250-300g),用细绳将容器悬在井水中,同时系一空瓶,

生活饮用水深度处理技术-膜分离技术论文

生活饮用水的深度处理技术-膜分离技术摘要:膜处理技术在国外已经发展成为饮用水深度处理的核心技术。本文指出了饮用水的处理要求,介绍了几种典型的膜分离技术:微滤、超滤,纳滤,反渗透。最后介绍了膜分离技术的优缺点。 关键字:微滤、超滤,纳滤,反渗透 abstract: the processing technology in foreign film has become the core technology of the deep treatment of drinking water. this paper points out that the drinking water treatment requirements, introduces several kinds of typical membrane separation technology: micro filter, ultrafiltration, nanofiltration, reverse osmosis. at last, the paper introduces the advantages and disadvantages of the membrane separation technology. key word: micro filter, ultrafiltration, nanofiltration, reverse osmosis 中图分类号:tu74 文献标识码:a 文章编号: 为保证饮用水质量,世界各国不仅及时修订了本国的水质标准,而且制定了控制水中有毒有害物质的对策。随着这些调查和研究工作的不断深人,人们逐步认识到,在很多情况下,常规的净化工艺已不能完全有效地去除水中的病原菌、病毒等。因此,以去除饮用水中有机污染及有毒有害物质为目标的饮用水深度净化技术得到 日益广泛的应用。

饮用水深度处理工艺设计

饮用水深度处理工艺设计 [摘要]针对饮用水水源有机物污染现象日趋严重,常规水处理工艺已难以生产出符合水质标准的饮用水,本文在常规饮用水处理的基础上设计了饮用水深度处理工艺,采用臭氧+砂滤+生物活性炭的新型组合工艺,能够有效保证饮用水的安全性。 [关键词]饮用水;深度处理;臭氧;生物活性炭 1.设计背景 饮用水的质量与人们的生活水平和身体健康息息相关。由于人们对饮用水水质的要求在不断提高,我国也提出了比现行饮用水水质标准(GB5749-85)更严格的2000年城市供水水质目标。 2.设计思想 2.1活性炭吸附 活性炭是一种具有较大吸附能力的多孔性物质。活性炭吸附在常规处理基础上去除水中有机污染物最有效最成熟的水处理深度处理技术。实验研究表明,饮用水处理中活性炭吸附去除的有机物的分子量主要分布在500-1000u(道尔顿)之间,分子量过大或过小吸附作用都较差。 2.2臭氧氧化 臭氧是一种氧化剂,它可以通过氧化作用分解有机污染物。臭氧可氧化溶解性铁、锰、氰化物、酚、致嗅物质和有色物质、生物难降解的大分子有机物等。 2.2.1去除无机物 臭氧预氧化可去除大多数无机物,但预氧化后必须有过滤或凝聚一絮凝一沉淀处理措施,以除去金属离子氧化后形成的不溶物。 2.2.2促进凝聚一絮凝处理 低剂量03(0.5g/m3lg/m3)就足以强化凝聚一絮凝处理。因为一些大分子溶解状污染物被03氧化后分子的极性变大,可与其他含有氢原子的有机物形成氢键,增加分子量,当这种达到一定程度时,溶解度将降低,产生微絮凝效果。 2.2.3氧化天然有机物 地表水和地下中含有大量会使水质恶化的有机物,另外,在末端氧化中腐殖

生活饮用水消毒剂和消毒设备卫生安全评价规范(试行)

生活饮用水消毒剂和消毒设备卫生安全评价规范(试行) 1.范围 根据《生活饮用水卫生监督管理办法》和《消毒管理办法》制定本规范,用于生活饮用水消毒剂和消毒设备的卫生安全评价,本规范规定了用于生活饮用水消毒的消毒剂和消毒设备的卫生安全要求和检验方法。 2.定义 下列定义适用于本规范。 2.1消毒剂杀灭生活饮用水中微生物的化学处理剂 2.2消毒设备产生生活饮用水消毒剂或消毒作用的设备 2.3消毒副产物消毒剂或消毒设备使用后在消毒生活饮用水过程中产生的副产物 2.4新产品依据新原理、新有效成分生产的消毒剂和消毒设备,以及消毒剂的新剂型和新复配制剂。 3.卫生要求 3.1所有消毒剂和消毒设备按说明书规定的使用方法,以表1所列检验步骤,检验结果均能达到生活饮用水消毒目的;各项微生物指标均符合现行《生活饮用水水质卫生规范》的要求。 3.2消毒剂和消毒设备在消毒过程中余留在生活饮用水中的消毒剂残留物、由原料和工艺过程中带入的杂质含量不应超过现行《生活饮用水水质卫生规范》限值要求;消毒过程中产生的消毒副产物浓度不应超

过现行《生活饮用水水质卫生规范》限值要求。 3.3消毒剂及其原料副产物和消毒设备使用后水中可能带入现行《生活饮用水水质卫生规范》未予规定的有害物质时,该有害物质在生活饮用水中的限值可参考国内外相关标准判定,且该有害物质增加量不应超过相关标准限值的10%。 如果上述有害物质没有可参考相关标准时,应按毒理学安全性评价程序进行试验以确定物质在饮用水中最高容许浓度。容许增加值为最高容许浓度值的10%。 3.4消毒剂卫生要求根据说明书规定的使用方法,按表2《生活饮用水消毒剂评价剂量》计算处理后生活饮用水中金属离子增加量、无机物增加量和有机物增加量不应超过现行《生活饮用水水质卫生规范》中规定限值的10%;总α放射性和总β放射性不应增加。 按表3《总体性能试验的检验项目》进行检验结果应符合现行《生活饮用水水质卫生规范》要求。 3.5消毒设备卫生要求根据说明书规定的使用方法,按表2《生活饮用水消毒剂评价剂量》计算处理后生活饮用水中金属离子增加量、无机物增加量和有机物增加量不应超过现行《生活饮用水水质卫生规范》中规定限值的10%;总α放射性和总β放射性不应增加。 按表3《总体性能试验的检验项目》进行检验结果应符合现行《生活饮用水水质卫生规范》要求。 消毒设备中与生活饮用水接触部分的浸泡试验应符合现行《生活饮用

饮用水水质问题及深度处理措施

饮用水水质问题及深度处理措施探讨摘要:水是人类生存必不可少的基本资源之一,然而,随着社会经济的现代化发展,饮用水水源收到了严重的污染。由于水厂所采用的传统处理工艺并不能很好地去除污染物,导致许多水厂所提供的生活饮用水存在水质不合格的现象,严重威胁了人们的健康。本文即针对饮用水水质及其处理中存在的问题进行了分析,并探讨了饮用水深度处理的相关措施。 关键词:饮用水;水质;深度处理;措施 abstract: water is essential to human survival of one of the basic resources, however, along with the social economy development of modernization, drinking water supply received serious pollution. because the traditional water treatment technology and can not very well to remove pollutants, causing many water provide the life there drinking water quality unqualified phenomenon, a serious threat to people’s health. this article is in the drinking water quality and the problems existed in the handling of the analysis, and discusses the depth of drinking water treatment measures. keywords: drinking water; water quality; deep processing; measures 中图分类号:k928.4文献标识码: a 文章编号:

安全饮用水的主要处理工艺流程 ()

安全饮用水的主要处理工艺流程 一、给水处理工艺流程概述 给水处理的任务是通过必要的处理方法去除水中杂质,使之符合生活饮用或工业使用所要求的水质。水处理方法应根据水源水质和用水对象对水质的要求胡定。在给水处理中,有的处理方法除了具有某一特定的处理效果外,往往也直接或间接地兼收其它处理效果。为了达到某一处理目的,往往几种方法结合使用。本节仅列出几种主要给水处理方法,以便于读者对给水处理有一概括的了解。 1.澄清和消毒 这是以地表水为水源的生活饮用水的常用处理工艺。但工业用水也常需澄清工艺。 澄清工艺通常包括混凝、沉淀和过滤。处理对象主要是水中悬浮物和胶体杂质。原水加药后,经混凝使水中悬浮物和胶体形成大颗粒絮凝体,而后通过沉淀池进行重力分离。过滤是利用粒状滤料截留水中杂质的构筑物,常置于混凝和沉淀构筑物之后,用以进一步降低水的浑浊度。完善而有效的混凝、沉淀和过滤,不仅能有效地降低水的浊度,对水中某些有机物、细菌及病毒等的去除也是有一定效果的。根据原水水质不同,在上述澄清工艺系统中还可适当增加或减少某些处理构筑物。例如,处理高浊度原水时,往往需设置泥沙预沉池或沉沙池;原水浊度很低时,可以省去沉淀构筑物而进行原水加药后的直接过滤。但在生活饮用水处理中,过滤是必不可少的。大多数工业用水也往往采用澄清工艺作为预处理过程。如果工业用水对澄清要求不高,可以省去过滤而仅需混凝、沉淀即可。 消毒是灭活水中致病微生物,通常在过滤以后进行。主要消毒方法是在水中投加消毒剂以灭致病微生物。当前我国普遍采用的消毒剂是氯,也有采用漂白粉、二氧化氯及次氯酸钠等。臭氧消毒也是一种消毒方法。 “混凝—沉淀—过滤—消毒”可称之为生活饮用水的常规处理工艺。我国以地表水为

饮用水处理技术研究进展

饮用水处理技术研究进展* 魏云霞1,李彦锋2#,刘晓丽2,叶正芳3 (1.兰州大学资源环境学院 甘肃 兰州 730000;2兰州大学化学化工学院 甘肃 兰州 730000; 3.北京大学环境科学与工程学院,北京 100871) 摘要简要介绍了饮用水的常规处理技术,指出了常规处理技术中的局限性,综述了目前几种饮用水深度处理工艺,包括活性炭吸附、臭氧氧化、生物活性炭、膜技术等,同时介绍了吸附和氧化两种预处理技术,最后对饮用水处理技术的发展方向进行展望。 关键词微污染水源水水处理技术 Treatment technology of micro-polluted drink water Wei Yunxia 1, Li Yanfeng2, Liu Xiaoli2, Ye Zhengfang 3.(1.College of Resources and Environment, Lanzhou University, Lanzhou Gansu 730000; 2.College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou Gansu730000; 3.Department of Environmental Engineering, Beijing University, Beijing 100871) Abstract:This article introduces the actuality of mankind drink water treatment methods from three sides. Firstly, the disadvantages of traditional water treatment technology are point out, and then some depth treatment technology such as active carbon adsorption, oxidation, and member technology are summarized, some pretreatment technology are introduced. Finally, the future direction of new research technology and methods are prospected. Keywords: micro-polluted;drink water;water treatment technology 一般来说,水源水所含的污染物种类较多、性质较复杂但浓度比较低微时,通常被称为微污染水。针对不同的污染类型,人们在饮用水常规处理工艺的基础上研究开发了很多新的工艺和技术,归结起来主要有常规水处理工艺;深度处理技术;源水预处理技术。 1 常规处理工艺及其局限性 1.1 饮用水常规处理工艺 饮用水常规处理技术是指传统的混凝—沉淀—过滤—消毒技术。这种常规处理工艺至今仍被世界大多数国家所采用,成为目前饮用水处理的主要工艺。饮用水常规处理工艺的主要去除对象是水源中的悬浮物、胶体杂质和细菌。混凝是向原水中投加混凝剂,使水中难以自然沉淀分离的悬浮物和胶体颗粒相互聚合,形成大颗粒絮体;沉淀是将絮凝后形成的大颗粒絮体通过重力分离;过滤则是利用颗粒状滤料截留经沉淀后出水中残留的颗粒物,进一步去除水中杂质,降低水的浑浊度。过滤之后采用消毒方法来灭活水中致病微生物,从而保证饮用水卫生安全。 1.2 常规处理的局限性 目前,世界上一些国家对受有机物污染的饮用水进行致突变试验,发现许多饮用水呈现阳性结果。我国的上海、武汉、哈尔滨、新疆的塔什库尔干、伽师等地的饮用水,在致 第一作者:魏云霞,女,1980年生,讲师,博士研究生,主要研究方向为环境污染修复与化学生物。 ?国家“十一五”计划支撑项目(No.2006BRD01B03);国家自然科学基金委员会人才培养基金资助项目(No.J0730425);甘肃省科技攻关计划项目资助项目(No.2GS064-A52-036-02)。

饮用水消毒方法

饮用水消毒方法的应用 1.大中型水厂目前我国极大多数水厂采用氯消毒。氯消毒效果好,具有持续消毒作用(管网余氯),且费用较其它消毒方法低。但是,由于氯气是具有刺激性和有害气体,对金属有极强的腐蚀性,因此采用氯消毒必须有专门的加氯机、加氯间和氯库,以保证加氯的安全性。通常将装有液氯的氯瓶放在磅秤上,在加氯过程中随时观察氯瓶重量度化,经以核对氯瓶中剩余液氯量,防止用空,使用时还应防止加氯机的水倒灌入氯瓶。因氯气比空气重,加氯间和氯库外墙的低处安装排风扇,以排除聚积在室内的氯气;氯库和加氯间内应安置漏气探测报警仪,以预防和处理氯气泄漏事故,在加氯间还应有应急中和处理池(池内装石灰水)。 加氯后,应加强余氯的连续监测,有条件时,加氯地点宜设置余氯连续测定仪。目前国内很多大型水厂采用自动化加氯,也有的水厂采用计算机控制加氯。 为减少沉淀池和滤池中藻类生长,有些水厂采用滤前加氯和滤后加氯的二次加氯方法。但滤前加氯可造成氯与水中有机物反应形成三卤甲烷等物质,因此目前提出在滤前采用臭氧或二氧化氯消毒,滤后采用氯消毒的方法。 小型水厂目前有采用氯消毒方法,也有采用漂白粉消毒。因漂白粉所含有效氯易挥发,每批购进的漂白粉应进行有效氯含量的测定。存放漂白粉的仓库应与漂白粉溶液投加间隔开,并保持阴凉,干燥和良好的自然通风条件。漂白粉溶解池和溶液池一般2个,便于轮流使用。池底坡度不小于2%并坡向排渣孔。因氯有腐蚀性,应有防腐蚀措施.加漂白粉间与—级泵房应隔开,并采用自然通风,室内地坪坡度不小于5%。 漂白粉投加方法:将每包50kg的漂白粉先加400—500kg水搅拌成10%-15%的溶液,再加水调成1%-2%浓度、澄清后、由计量设备投到滤后水中,可采用重力将漂白粉溶液投加到水泵吸水管中,也可用水射器向压力管中投加。 2.企业、农村水厂 2.1企业水厂的消毒企业由于供水量较小,管网相对集中,目前采用的饮水消毒方法较多。有氯化消毒、漂白粉消毒、也有采用臭氧消毒、紫外线消毒和二氧化氯消毒,还有部分采用次氯酸钠消毒。 次氯酸钠是由次氯酸钠发生器将食盐电解后产生的,其有效氯含量在1%-5%。次氯酸钠容易受阳光、温度的作用而分解,因此次氯酸钠宜就地制备和投加。工业制备的次氯酸钠有效氯含量在10%-12%,但由于其不稳定性,在购进时应测试其有效氯含量。存放时间应在1月以内。投加方法要用重力投加,通过水封箱加注到水泵吸水管中,也可用水射器向压力管中投加。加药浓度以有效氯含量在l-6mg/L时每吨水约加10-60ML

几种饮用水消毒方式比较

各种消毒模式的分析与评价: 目前,从水体消毒的种类来说,有氯气、漂白粉、次氯酸钠、氯胺、二氧化氯、臭氧等药剂和紫外线消毒模式,每种消毒模式都具有不同的性能和特点。 我国大多数集中式供水采用氯消毒。氯消毒效果好,且费用较其他消毒方法低。但由于近年来地下水质中各种有机物含量的增加,运用氯消毒会产生三卤甲烷等致突变与致癌变的有机化合物,因此专家建议不宜单独使用氯消毒。也有采用漂白粉、次氯酸钠消毒的,因漂白粉、次氯酸钠容易受阳光、温度的作用而分解,所含有效氯易挥发,所以对存放条件和有效氯测试的要求比较高。使用氯胺消毒需要较长的接触时间,操作比较复杂,并且氯胺的杀菌效果差,不宜单独作为饮用水的消毒剂使用。而紫外线的灭菌作用只在其辐照期间有效,所以被处理的水一旦离开消毒器就不具有残余的消毒能力,如果一个细菌未被灭活而进入后续系统,就会沾附在下游管道表面并繁衍后代,容易造成二次污染。为保障农村供水安全,必须选择能替代氯消毒的、适合农村特点的、经济安全的消毒方法。其中,较为理想的是二氧化氯(CIO2)和臭氧(O3)。 二氧化氯(CIO2) 二氧化氯的应用现状 20世纪40年代,欧洲一些国家发现CIO2用于水的消毒有很好的效果,但因制造复杂,价格较贵,一直未受到重视。近年来,国外在避免氯消毒所引起的有害作用而寻找新的消毒剂时,对CIO2的研究和应用日益增多。由于CIO2不会与有机物反映而生成三氯甲烷,所以在饮用水处理中应用越来越广泛。二氧化氯消毒的安全性被世界卫生组织(WHO)列为A1级,被认定为氯系消毒剂最理想的更新换代产品。目前,美国和欧洲已有上千家水厂采用二氧化氯消毒,我国近两年采用二氧化氯消毒的水厂也逐渐增多。 二氧化氯的制备方法 由于二氧化氯水溶液易挥发,对压力、温度和光线敏感,所以不能压缩进行液化储存和运输,只能在使用时现场制备,立即使用。二氧化氯的制备方法有电解食盐法、化学反应法、离子交换法等。其中电解法和化学法在生产上应用较多。 臭氧(O3) 臭氧的应用现状 目前,在欧洲主要城市已把臭氧作为深度净化饮用水的一种主要手段。20世纪70年代初以来,许多国家还对臭氧应用于城市污水、工业废水、循环冷却水处理进行了研究,并有很多成功的例子。在我国,臭氧消毒总的来说是处在起步阶段,尤其是水厂净水处理工艺,但在区域供水工程中,臭氧消毒得到了一定的应用,积累了一些经验。

国内外饮用水的预处理和深度处理

国内外饮用水预处理与深度处理技术 学生:曾雪萍学号:20086814 摘要:随着有机化工、石油化工、采矿、农药和医药工业的迅速发展,造成水源水污染的有害物质数量也逐年增多。水源水中的人工合成有机物污染、内分泌干扰物污染等问题都开始受到人们的关注。这些污染物浓度很低,但很难通过常规的水处理工艺有效去除,且来源难以确定,已成为饮用水水质净化面临的重要挑战。研究表明,通过对原水采用预处理,以及在常规水处理后再进行深度处理可以改善和提高饮用水水质。关键词:饮用水预处理深度处理 一、饮用水预处理 预处理通常是指在常规处理工艺前面采用适当的物理、化学和生物的处理方法,对水中的污染物进行初级去除。同时使常规处理更好的发挥作用,减轻常规处理和深度处理的负担,发挥水处理工艺的整体作用,改善和提高饮用水水质。 工程中可采用的预处理方法有:生物预处理法、化学预氧化法、粉末活性炭法等。(1)生物预处理法 针对水源水被污染的特性,可适时增加生物预处理。生物预处理主要是对原水进行曝气或其他生物处理,去除水中氨氮和生物可降解有机物,包括生物接触氧化池和曝气生物滤池等。1971年,日本的小岛贞男首次成功地将生物接触氧化法应用于富营养化水源水预处理,去除藻类60%^80%,氨氮90%以上,嗅味50%-70%,使水厂出水水质得到明显改善,把本来属于污水处理应用范畴的生物法引人了给排水处理领域。 生物预处理工艺以生物膜法为主导,生物预处理的填料上生长着细菌、原生动物、后生动物等微生物形成生物膜,在与水接触时,生物膜上的微生物摄取、分解水中的有机物和氮、磷等营养物质。去除常规工艺不能充分去除的氨氮、亚硝酸盐氮、藻类、可生物降解有机污染物等,此外,还能去除或减少可能在加氯后生长的致突变物质的前驱物,不同程度地去除原水中的铁、锰、色、嗅及浊度,从而使水得到净化。其中,CODMn,,去除率一般为15%-20%,氨氮和亚硝酸盐去除率可高达80%以上。 生物预处理适合于水中有机污染物可生化性较强、无工业废水污染的情况,,对优先污染物去除效果也不佳,且无法间歇运行等。如果原水受生活污水污染,有机物和氨氮较高〔接近或超过《地表水环境质量标准》(GB 3838-2002) 中的111类水体的上限〕,与增加臭氧一活性炭深度处理相比,选用生物预处理是解决该类水质问题的经济合理的选择方案。生物预处理方案的确定应结合已有研究成果和原水水质特征进行必要的模拟试验,确定生物预处理的工艺适用性、池型及设计和运行参数。 (2)化学预氧化法 化学预氧化法是将氯、臭氧、高锰酸盐等氧化势较高的氧化剂投加到原水中,以氧化或者催化氧化水中的有机物或改变有机物的性质,同时削弱污染物对常规处理工艺的不利影响,强化常规处理工艺的除污效能。化学预氧化的目的主要是为去除水中有机污染物和控制氧化消毒副产物,从而保障饮用水的安全性。此外预氧化的目的还有除藻、除嗅和味、除铁和锰、氧化助凝等作用。 在传统给水处理工艺中,可在多个点加人氧化剂,氧化剂在不同点起着不同的作用。在预处理过程中,氧化剂和水中多种成分作用,能够提高对有害成分的去除效率,但各种氧化剂作为预处理对给水处理的综合影响程度较大。目前,能够用于给水处理的氧化剂主要有臭氧、高锰酸盐、氯、二氧化氯、过氧化氢等。

生活饮用水杀菌消毒方案

生活饮用水杀菌消毒方案 紫外线杀菌原理和相关知识:紫外线是一种肉眼无法看见的光线,根据波长的不同可细分 UVA(315~400nm)UVB(280~315nm)UVC(200~280nm)。UVC最易被DNA(核糖核酸)吸收,紫外线消毒系统就是使用UVC。莱特莱德紫外线杀菌设备集光学、微生物学、机械、化学、电子、流体力学等综合学科于一体。采用特殊设计的高效率、高强度和长寿命的紫外C光发生装置产生的强紫外C光照射流水。当水中的细菌、病毒、藻类生物等受到一定剂量的紫外C光(波光253.7nm)照射后,其细胞的DNA、RNA结构被破坏,细胞再生无法进行,从而达到水的消毒和净化的目的。 波长185nm谱线在空气中产生臭氧,而臭氧可起到杀菌、除味的效果。185nm的谱线还可以分解水中的有机物分子,产生氢基自

由基并最终将水中的有机物分子氧化为二氧化碳,达到去除TOC的目的。 生活饮用水工艺流程图 工艺流程:生活饮用水(自来水)→石英砂过滤器→活性炭过滤器→(软化器)→精密过滤器→反渗透膜/纳滤膜/超滤膜→紫外线杀菌系统→水箱(生活直饮水/生活饮用水) 石英砂过滤器:采用水泵加压,使原水通过过滤介质,去除水中的悬浮物,从而达到过滤的目的。特点:运行可以实现自动控制,过滤效率高,阻力小,处理流量大,反冲次数少。应用范围:广泛应用于纯水、食品饮料水、矿泉水和电子、印染、造纸、化工行业水质的预处理及工业污水二级处理后的过滤。也用于中水回用系统、游泳池

循环水处理系统的深度过滤。对于工业废水中的悬浮物也有很好的去除效果。 活性炭过滤器过滤:介质:活性炭,工作原理:利用活性炭的吸咐性能去除液体中的杂质使液体得到净化。 特点: 1、能吸附水中的有机物、胶体微粒、微生物。 2、可吸附氯、氨、溴、碘等非金属物质。 3、可吸附金属离子,如银、砷、钗、六价铬、汞锑、锡等离子。 4、可有效去除色度和气味及制药工业除去水中热源,延长交换树脂的使用寿命。 软化器:又称离子交换器,离子交换器是用于降低水中的硬度,生水由上而下通过交换器进行软化,水中含有的镁、钙、阳离子与水交换剂的钠离子互相交换,使水中不易形成碳酸盐垢及硫酸盐垢,从而获得软化水。 精密过滤器:也叫保安过滤器:采用PP棉、尼龙、熔喷等不同材质作滤芯.工作原理:通过不同孔径的滤芯去除水中的微小悬浮物,细菌及其它杂质等,使原水水质达到反渗透膜的进水要求。 反渗透膜:在高于溶液渗透压的作用下,依据其他物质不能透过半透膜而将这些物质和水分离开来。反渗透膜的膜孔径非常小,因此能够有效地去除水中的溶解盐类、胶体、微生物、有机物等。 水箱:不锈钢纯水箱,304或316材质,多种规格型号,主要用于水处理未端的水质储存。

纳滤膜技术深度处理饮用水

纳滤膜技术深度处理饮用水 发布时间:2013-3-11 9:13:43 中国污水处理工程网 随着各种洗涤剂、农药、化肥的大量使用以及生活污水、工业废水排放量的增加,加剧了我国地表及地下水源的污染。水体中污染物浓度和种类不断增加,其中部分难降解物质性质非常稳定,采用传统的饮用水处理技术难以去除,且加氯消毒还有形成消毒副产物的风险。为了保证出水安全性,必须对饮用水进行深度处理。饮用水深度处理主要有活性炭吸附、o3氧化、膜分离及其组合工艺。其中,膜分离技术因对水中难降解污染物去除效果好,对药剂无依赖性,高效节能而被广泛应用,并被公认为饮用水深度处理先进技术。 1 纳滤在饮用水处理中的优势 相比微滤、超滤和反渗透这3种膜分离技术,纳滤在饮用水深度处理中更具优越性。纳滤膜是一种低压反渗透膜,分离性能介于超滤和反渗透之间,不仅能有效去除水中的重金属、无机盐、天然与合成有机物、微生物等有害物质,还能保留对人体有益的矿物质和微量元素,产水安全卫生,有益人体健康。因此,纳滤膜技术被认为是最有发展潜力的饮用水深度处理技术。 1纳滤在饮用水处理中的优势 相比微滤、超滤和反渗透这3种膜分离技术,纳滤在饮用水深度处理中更具优越性。纳滤膜是一种低压反渗透膜,分离性能介于超滤和反渗透之间,不仅能有效去除水中的重金属、无机盐、天然与合成有机物、微生物等有害物质,还能保留对人体有益的矿物质和微量元素,产水安全卫生,有益人体健康。因此,纳滤膜技术被认为是最有发展潜力的饮用水深度处理技术。 2纳滤膜的特征及分离机理. 2.1纳滤膜特征 (1)纳米级孔径。纳滤膜孑L径为纳米级(10-9m),适于截留粒径1nlTl左右,分子量在200一l000的物质。 (2)离子选择性。纳滤膜上或膜中带有负的带电基团。由于静电作用,纳滤膜对二价和多价离子的截留率比一价离子高得多2。 (3)操作压力低。纳滤分离的操作压力一般为0.5—2.0MPa,比达到相同渗透通量的反渗透分离所需压差低0.5—3.0Mpa。

超滤技术在饮用水深度处理上的应用

超滤技术在饮用水深度处理上的应用 超滤技术在饮用水深度处理上的应用 摘要:随着社会的发展与进步,重视超滤技术在饮用水深度处理上的应用对于现实生活具有重要的意义。本文主要介绍超滤技术在饮用水深度处理上的应用的有关内容。 关键词:超滤技术;深度处理;饮用水;应用; 中图分类号:TV213 文献标识码:A 文章编号: 引言 水资源短缺问题是人类社会生存和发展的瓶颈: 一方面,随着经济社会的发展,人们对水资源水质和需求量的要求都在不断提高; 另一方面,随着环境污染的加剧,可供人们利用的水资源却越来越少。要破解水资源短缺的困局,一方面,开发新型的水处理技术,提高处理水水质; 另一方面,不断开发新的水资源,如海水淡化、废水循环利用等。超滤技术作为一种新型高效的水处理技术应运而生。 一、超滤技术基本原理 超滤膜对溶质的分离机理为: 一次吸附、阻塞、筛分。其中,筛分是在压力作用下,溶剂和小分子的溶质透过膜到低压侧,而被膜阻挡,料液逐渐被浓缩而后以浓缩液排出。因此,可以用微孔模型表示超滤的传递过程。 二、超滤的技术优点 ( 1) 超滤是一种绿色物理分离技术, 其分离机理主要是筛分和扩散作用。即使不加混凝剂, 也能有效去除原水中的悬浮物和胶体物质, 将出水浊度降至0. 1 NTU 以下。因此超滤可少用甚至不用混凝剂, 从而减少混凝药剂对水质的污染。 ( 2) 超滤技术可有效去除几乎全部致病微生物, 包括隐孢子虫、贾第虫、细菌和病毒等, 出水水质一般可达到水质标准对微生物指标的要求, 因此原则上没有必要再对出水进行杀菌消毒。当然, 还需向水中投加少量消毒剂, 以保持一定的持续消毒能力, 以免水在输配过程中受到二次污染。

浅析生活饮用水的消毒方式

浅析生活饮用水的消毒方式 【摘要】本文对生活饮用水中常用的几种消毒方法进行了介绍,讨论了液氯、二氧化氯及氯胺消毒工艺的原理、优点、缺点及影响因素。同时提出了安全消毒的概念,指出紫外线+氯组合消毒工艺是保障消毒安全的重要技术选择。 【关键词】饮用水;消毒方式 一、常规饮用水消毒方式及影响因素 水厂传统的饮用水常规消毒方式主要有液氯消毒和二氧化氯消毒,近几年又开始采用氯胺消毒的方式进行消毒。这些消毒方式各有利弊,分析如下: 1.液氯消毒 (1)原理。液氯消毒是将液氯气化后变成气相氯气,通过加氯机投入水中。HCIO和CIO-都具有氧化能力,但HCIO是中性分子,可以靠近附着在带负电荷细菌的表面,并渗入到细菌体内,对细菌进行氧化,进而造成细菌死亡;而CIO-带负电,难于扩散到带负电荷的细菌附近,所以CIO-虽有氧化能力但对水却难起消毒作用。在我国用液氯作消毒剂对自来水消毒十分普遍。 (2)优点。一是杀菌效率高。氯气是一种强氧化剂和广谱杀菌剂,能有效杀死水中的细菌和病毒。二是持续性好。氯气具有持续消毒能力是因为水体经氯消毒后能长时间地保持一定数量的余氯,能达到良好的消毒效果。 (3)缺点。一是存在二次污染。氯与污水中某些有机物反应,生成一系列含氯化合物,大部分对人体健康有害。二是安全性较差。液氯有毒,有泄露的风险,存在安全隐患。三是形成氯胺,降低消毒能力。氯与氨反应生成氯胺,会影响消毒效果。 (4)影响因素。一是接触时间。氯加入水中后,保证与水有一定的接触时间,是充分发挥消毒作用的有效条件。二是pH。水的pH越低,所含HCIO越多,当pH9时,CIO-接近100%。三是温度。温度越高,氯对微生物的杀灭效果越好,水温每升高lO℃,病菌杀灭率提高2倍~3倍。 2.二氧化氯消毒 (1)原理。二氧化氯可有效氧化细胞内含疏基的酶;对细胞壁有较好的吸附性和渗透能力,可与半胱氨酸、色氨酸和游离脂肪酸反应,快速控制生物蛋白质的合成,并能改变病毒衣壳蛋白,导致病毒灭活。二氧化氯原子为正4价,还原成氯化物时可得到5个电子,是国际上公认的含氯消毒剂中唯一的高效消毒剂,它可以杀灭包括细菌繁殖体,细菌芽孢,真菌,分枝杆菌和病毒等微生物。

饮用水深度处理工艺选择及工程实例

饮用水深度处理工艺选择及工程实例 摘要:新国标《生活饮用水卫生标准》(GB5749-2006)将于2012年7月1日强制执行,但目前饮用水水源污染严重,水处理工艺落后,国内自来水水质状况令人担忧。本文介绍活性炭+超滤膜组合工艺组合工艺及工程应用实例,供水厂升级改造选择。 关键词:饮用水深度处理,臭氧-生物活性炭,膜处理,工程实例Abstract: new gb “life sanitary standard for drinking water” (GB5749-2006) will be on July 1, 2012 compulsory execution, but the drinking water sources pollution is serious, water treatment process behind, domestic running water quality condition is anxious. This paper introduces activated carbon + ultrafiltration membrane combination craft combination technology and engineering application examples, the water supply factory upgraded choice. Keywords: drinking water depth processing, ozone-biological activated carbon, film processing, engineering example 中图分类号:TU991文献标识码:A 文章编号: 0 引言 随着2012年7月1日新国标《生活饮用水卫生标准》(GB5749-2006)即将强制执行,公众对水质标准与国际标准接轨的呼声也越来越高。新国标相对现在实行的1985版本相比,加强了对水质有机物、微生物和消毒副产物等方面的要求。指标数量高达106项,其中包括6项微生物指标,这与世界最严的水质标准——欧盟水质标准持平。 有媒体报道“全国普查自来水合格率仅50%”,而据住建部城市供水水质监测中心2011年最新抽样检测,我国自来水厂出厂水质达标率也仅为83%。 针对目前十分严峻的饮用水水源污染现状,开发可靠、经济,与水源水质相适应的饮用水深度处理技术,保证饮用水安全是目前亟待解决的重要问题。 1 国内外深度处理主流工艺

优质饮用水的消毒方法

优质饮用水的消毒方法 王宝贞1,王欣泽1,李 冰2,张广群1 (1.哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090;2.大庆油田设计研究院,黑龙江大庆163712) 摘 要:饮用水中常见的消毒工艺包括液氯、氯胺、二氧化氯、臭氧、紫外线和膜消毒等.分析了各种消毒工 艺的机理、运行特点和对各种病原微生物的处理效率.饮用水深度净化工艺能够很好地去除水中消毒副产 物前驱物质及病原微生物,提出以氯胺或二氧化氯作为最终的消毒剂,而臭氧氧化可以作为预处理的处理方 案.分析了紫外线消毒技术的应用范围. 关键词:消毒;深度净化;饮用水 中图分类号:T U991.25 文献标识码:A 文章编号:036726234(2002)0420478205 Disinfection of high quality drinking w ater W ANG Bao2zhen1,W ANG X in2ze1,LI Bing2,ZH ANG G uang2qun1 (1.School of Municipal and Environmental Engineering,Harbin institute of technology,Harbin150090,China;2.Daqing Oil Field Design and Research Institute,Daqing163712,China) Abstract:The comm on disin fecting process of drinking water includes free chlorine,chloramine,chlorine dioxide, ozone,UV and membrane etc.The disin fection mechanism,operation characteristic and pathogenetic microorgan2 isms rem oval efficiency of each disin fection process was discussed.With advanced drinking water treatment technol2 ogy the disin fecting by2products formation potential and pathogenetic microorganisms can be effectively rem oved.It was recommended that chloramine or chlorine dioxide is used as final disin fectants and ozone oxidation as pretreat2 ment.The application range of UV disin fection technology was als o discussed. K ey w ords:disin fection;advanced treatment;drinking water 随着人们生活水平的提高和水处理工艺的发展,传统的混凝沉淀砂滤工艺已不能满足人们的要求,饮用水深度净化工艺在国内外得到了广泛的研究和应用.在发达国家,市政自来水的水质是以满足直接饮用为目标的,而在我国,管道直饮水技术指对市政自来水进行深度处理,采用单独的供水管道供给用户,满足生饮需要.目前在一些经济较为发达城市的新建小区中,已逐步开始建立饮用水深度净化工程. 水质标准的提高对消毒工艺提出了挑战,在 收稿日期:2002-01-09. 基金项目:“九五”国家科技攻关项目(96-9090003-03). 作者简介:王宝贞(1932-),男,教授,博士生导师.美国总大肠杆菌标准(T otal C oliform Rule)中提出了对去除水中大肠杆菌的更为严格的标准和更为严格的检测手段,而另一方面消毒剂和消毒副产物标准(Disin fectantsΠDisin fection By-product Rules)却严格地限制了水中消毒剂和消毒副产物的最大值,这使得微生物的灭活要求又难以满足,尤其是近年来研究较多的对人们的健康构成较大威胁的贾第虫和隐孢子虫的灭活要求难以满足[1].当前水源水质恶化主要是以有机污染为主[2],水中的有机物质通过常规的混凝-沉淀-砂滤工艺难以达到非常理想的处理效果.许多天然有机物质如腐殖质,能够与消毒剂Cl 2 发生化学反应,形成消毒副产物.在饮用水深度净化工艺中,采用合理的消毒方法,在保证去除致病菌的 第34卷 第4期 哈 尔 滨 工 业 大 学 学 报 V ol.34 N o.4 2002年8月 JOURNA L OF H ARBI N I NSTIT UTE OF TECH NO LOGY Aug.,2002

灾区生活饮用水消毒方法

灾区生活饮用水消毒方法 为保证灾区民众能够得到安全的生活饮用水,须做好生活饮用水水源地的保护,水质的消毒处理以及水质的检验。 B.1饮用水的处理与消毒 煮沸是最简单有效的消毒方式,在有燃料的地方可采用。煮沸消毒的同时可杀灭寄生虫卵,所有饮用水提倡煮沸后饮用。 根据水源水状况,选择适宜的化学消毒剂,在专业人员的指导下,参阅消毒剂使用说明书,控制消毒剂用量和接触时间。 B.1.1缸(桶)水消毒处理 自然灾害发生后,若取回的水较清澈,可直接消毒处理后使用。若很混浊,可经自然澄清或用明矾混凝沉淀后再进行消毒。常用的消毒剂为漂白精片或泡腾片。按有效氯4-8mg/L投药,先将漂粉精片或泡腾片压碎放入碗中,加水搅拌至溶解,然后取该上清液倒入缸(桶)中,不断搅动使之与水混合均匀,盖上缸(桶)盖,30min后测余氯0.3-0.5mg/L即可。若余氯达不到,则应增加消毒剂量,缸(桶)要经常清洗。 B.1.2手压井的消毒 手压井一般只经过消毒处理,水质即可达到生活饮用水卫生标准的基本要求。消毒方法同缸(桶)水消毒处理。 B.1.3大口井的消毒 B.1.3.1直接投加法 投消毒剂前先测量井水量及计算投药剂量,水井一般为圆筒状,即

井水量(t)=井水深(m)×3.14×[水井半径(m)]2 漂白粉的投加量(g)=漂白粉有效氯含量%(井水量(吨)×加氯量(mg/L)) 加氯量应是井水需氯量与余氯之和,可根据井水水质按一般清洁井水的加氯量为2mg/L,水质较浑浊时增加到3-5mg/L,以保证井水余氯在加氯30min后在0.7mg/L左右,有条件的地区可进行水质细菌学检验。 投加的方法是根据所需投药量,放入容器中,加水调成浓溶液,澄清后将上清液倒入水桶中,加水稀释后倒入水井,用水桶将井水震荡数次,使之与水混匀,待30min后即可使用。井水的投药消毒至少每天2次,即在早晨和傍晚集中取水时段前进行。 B.1.3.2持续消毒法 将漂白粉或漂粉精片装入开有若干个小孔(孔径为0.2-0.5cm,小孔数可视水中余氯量调整)的饮料瓶中(每瓶装250-300g),用细绳将容器悬在井水中,同时系一空瓶,使药瓶漂浮在水面下10cm处。利用取水时的震荡使瓶中的氯慢慢从小孔中放出,达到持续消毒的目的。一次加药后可持续1周左右。采用本法消毒,应有专人负责定期投加药物,测定水中余氯,余氯量在0.7mg/L左右。若水井较大,可同时放数个持续消毒瓶。 B.1.3.3超量氯消毒法 经水淹的水井必须进行清淘、冲洗与消毒。先将水井掏干,清除淤泥,用清水冲洗井壁、井底,再掏尽污水。待水井自然渗水到正常水位后,

相关文档
最新文档