各国插脚标准

合集下载

世界各国插头型式一览表

世界各国插头型式一览表

世界各国插头型式一览表插头型式ANEMA 1-15P NEMA 1-15P NEMA1-15P 日本 JIS C 8303日本 JIS C 8303日本 JIS C 8303 日本 JIS C 8303 日本 JIS C8303 YP-11标准:NEMA 1-15PCSA CAN/CSA-22.2 No.21-95电源线:SPT-1 x 2C 18AWG SPT-2 x 2C 18AWG SPT-2 x 2C 16AWG SVT x 2C 18AWG额定电流/电压:10A 125V安全认证:YP-11C标准:NEMA 1-15PCSA CAN/CSA-22.2 No.21-95电源线:SPT-1 x 2C 18AWG SPT-2 x 2C 18AWG SPT-2 x 2C 16AWG SVT x 2C 18AWG额定电流/电压:10A 125V安全认证:YP-11W标准:NEMA 1-15PCSA CAN/CSA-22.2 No.21-95电源线:SPT-1 x 2C 18AWG SPT-2 x 2C 18AWG SPT-2 x 2C 16AWG SVT x 2C 18AWG额定电流/电压:10A 125V安全认证:YP-13标准:Japan JIS C 8303 Taiwan CNS 6797电源线:(H)(V)FF / 0.75mm 2/ 7A,125V~ (H)(V)FF / 1.25mm 2 / 12A,125V~ (H)VCTF / 0.75mm 2 / 7A,125V~ (H)VCTF / 1.25mm 2 / 12A,125V~ (H)VCTF / 2.00mm 2 / 15A,125V~ (H)VCTFK / 0.75mm 2 / 7A,125V~(H)VCTFK / 1.25mm 2 / 12A,125V~ (H)VCTFK / 2.00mm 2 / 15A,125V~安全认证:YP-13D标准: Japan JIS C 8303电源线:(H)(V)FF/ 0.75mm 2/ 7A,125V~ (H)(V)FF / 1.25mm 2 / 12A,125V~ (H)VCTF / 0.75mm 2 / 7A,125V~ (H)VCTF / 1.25mm 2 / 12A,125V~ (H)VCTF / 2.00mm 2 / 15A,125V~ (H)VCTFK / 0.75mm 2 / 7A,125V~ (H)VCTFK / 1.25mm 2 / 12A,125V~(H)VCTFK / 2.00mm 2 / 15A,125V~安全认证:YP-13L标准:Japan JIS C 8303 Taiwan CNS 6797电源线:(H)(V)FF/ 0.75mm 2/ 7A,125V~ (H)(V)FF / 1.25mm 2 / 12A,125V~ (H)VCTF / 0.75mm 2 / 7A,125V~ (H)VCTF / 1.25mm 2 / 12A,125V~ (H)VCTF / 2.00mm 2 / 15A,125V~ (H)VCTFK / 0.75mm 2 / 7A,125V~(H)VCTFK / 1.25mm 2 / 12A,125V~ (H)VCTFK / 2.00mm 2 / 15A,125V~安全认证:YP-15标准:Japan JIS C 8303 Taiwan CNS 6797电源线:(H)VCTF / 0.75mm 2(H)VCTF / 1.25mm 2额定电流/电压:7A 125V (0.75mm 2) 11A 125V (1.25mm 2)安全认证:YP-15G标准: JIS C 8303 电源线:(H)VCTF / 0.75mm 2(H)VCTF / 1.25mm 2额定电流/电压:7A 125V安全认证:插头型式BNEMA 5-15P NEMA 5-15P NEMA 5-15PUL - CSA/ Asia UL - CSA/ Asia UL - CSA/ Asia UL - CSA / AsiaNEMA 6-20P NEMA 6-20P NEMA 5-20P NEMA 5-20PUL - CSA / AsiaNEMA 6-15P NEMA 6-15PYP-12标准:NEMA 5-15PCSA CAN/CSA-22.2 No.21-95电源线:SVT x 3C 18AWG SJT x 3C 18AWG SJT x 3C 16AWG SPT-2 x 3C 18AWG SPT-2 x 3C 16AWG额定电流/电压:10A 125V安全认证:YP-12L标准:NEMA 5-15PCSA CAN/CSA-22.2 No.21-95电源线:SVT x 3C 18AWG SJT x 3C 18AWG SJT x 3C 16AWG SPT-2 x 3C 18AWG SPT-2 x 3C 16AWG额定电流/电压:10A 125V安全认证:all the configurations:YP-12LYP-12L-2YP-12L-3YP-12L-4YP-12L-5YP-12L-6YP-12L-7YP-12L-YP-12标准: JIS C 8303 (Japan); CNS 6797 (Taiwan) 电源线:(H)VCTF / 0.75mm 2(H)VCTF / 1.25mm 2额定电流/电压: 10A 125V安全认证:YP-18标准: NEMA 5-15P Hospital Grade电源线:SJTW 12AWG SJTW 14AWG额定电流/电压: 16A 125V安全认证:Marking:Hospital grade green dotYP-18L标准:NEMA 5-15P Hospital Grade电源线:SJTW 12AWG SJTW 14AWG额定电流/电压: 16A 125V安全认证:Marking:Hospital grade green dotall the configurations:YP-18LYP-18L-2YP-18L-3YP-18L-4YP-18L-5YP-18L-6YP-18L-7YP-18L-YP-19标准: NEMA 6-15P 电源线:SJT, SJTW 12AWG SJT, SJTW 14AWG额定电流/电压: 15A 250V安全认证:YP-19L标准: NEMA 6-15P电源线:SJT, SJTW, SJTOW, ST, STW 12AWG SJT, SJTW, SJTOW, ST, STW 14AWG额定电流/电压: 15A 250V安全认证:插头型式CYP-36标准:Australia AS/NZS 3112 without ground pin电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压: 10A / 250V安全认证:YP-57标准: IRAM 2063 (without ground pin) 电源线:H05VV-F x 3C 0.75mm 2H05VV-F x 3C 1.0mm 2额定电流/电压: 10A / 250V安全认证:UL-AR插头型式DYP-35标准:澳洲规格 AS 3112 纽西兰规格 NZS 3112电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压: 10A / 250V安全认证:YP-37标准: IRAM 2073电源线:H05VV-F x 3C 0.75mm 2H05VV-F x 3C 1.0mm 2额定电流/电压:10A / 250V安全认证: UL-ARYP-03标准: GB 1002电源线:RVV(H05VV-F) x 3C 0.75mm 2RVV (H05VV-F) x 3C 1.0mm 2额定电流/电压: 10A / 250V~安全认证:YP-03L标准: GB 1002电源线:RVV(H05VV-F) x 3C 0.75mm 2RVV (H05VV-F) x 3C 1.0mm 2额定电流/电压: 10A / 250V~安全认证:插头型式EYP-21标准:CEE7 standard XVI (CEE 7/16) "Europlug"Pin diameter: 4.0mm电源线: H03VVH2-F 0.75mm 2额定电流/电压:2.5A / 250V安全认证:YP-21K标准: Korea KS C 8305Pin diameter: 4.8mm电源线: H03VVH2-F 0.75mm 2额定电流/电压:3A / 250V安全认证:YP-47标准: Israel standard SI-32 Pin diameter: 4.0mm电源线: H03VVH2-F 0.75mm 2额定电流/电压:10A / 250V安全认证:插头型式FCEE7 standard DIN VDE 0620/05 CEE7 standard 韩国 KSC8305European European 韩国 EK markYP-24标准: CEE7 standard sheet XVII (CEE7/17) 电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压: 10A,16A / 250V安全认证:YP-24L标准: CEE7 standard sheet XVII (CEE7/17)电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压: 10A,16A / 250V安全认证:YP-24K标准: 韩国 KSC8305 电源线: VCTF 0.75mm 2额定电流/电压: 10A / 250V安全认证:插头型式GCEE7 standard sheet CEE7 standard sheetKorea KSC 8305YP-22标准:CEE7 standard sheet VII European plug / Schuko plug (CEE7/7) IEC 60884-1Dimensions: pin diameter: 4.0mmpitch: 19mmConnection toprotective ground: earthing clips on the sides, female earth contact电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压:10A,16A / 250V安全认证:YP-23标准:CEE7 standard sheet VII European plug / Schuko plug (CEE7/7) IEC 60884-1Dimensions: pin diameter: 4.0mmpitch: 19mmConnection toprotective ground:: earthing clips on the sides, female earth contact电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压: 10A,16A / 250V安全认证:YP-22K标准: Korea KSC8305 电源线: VCTF 0.75mm 2额定电流/电压: 7A / 250V安全认证:插头型式I英国规格BS 1363英国规格BS 1363A ASTA CertificationsASTA CertificationsYP-60标准:英国规格BS 1363电源线: H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压: 16A / 250V安全认证:ASTA新加坡PSBYP-61标准:英国规格BS 1363A(knocks withstand capability)乌地阿拉伯 SASO 2203电源线:H05VV-F 0.75mm2H05VV-F 1.00mm2额定电流/电压:3A,5A,10A,13A / 250V安全认证:ASTA 新加坡PSB 沙乌地阿拉伯SASOHong KongHK safetymarkYP-02标准: China GB1002-96 standard电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压:10A / 250V安全认证:YP-02L标准: China GB1002-96 standard 电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压:10A / 250V安全认证:英国标准BS 546南非标准SABSYP-81标准:英国标准 BS 546 南非标准 SABS 164-1电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压:6A / 250V安全认证:南非SABS印度 STQC 'S' markYP-46标准: 瑞士 SEV1011 电源线:H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压:10A / 250V安全认证:YP-45标准: 意大利规格 CEI 23-16 电源线:H03VVH2-F 0.75mm 2H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压:10A / 250V安全认证:YP-26标准: Denmark AFSNIT 107-2-D1 电源线:H03VVH2-F 0.75mm 2H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压:10A / 250V安全认证:插头型式PYP-48标准: 以色列规格 SI-32 电源线:H03VVH2-F 0.75mm 2H05VV-F 0.75mm 2H05VV-F 1.00mm 2额定电流/电压: 2.5A / 250V10A / 250V安全认证:欢迎您的下载,资料仅供参考!致力为企业和个人提供合同协议,策划案计划书,学习资料等等打造全网一站式需求。

各国插脚标准

各国插脚标准

Measured (mm)
澳规插脚尺寸要求之一
澳规插脚尺寸要求之二
阿规插脚尺寸要求之一
阿规插脚尺寸要求之二
Symbol
Requirement (mm)
A
8.0 min.
B
7.92
C
7.92
D
6.86
E
6.86
F
60
G
60
Measured (mm)
Symbol H I J K L M N
Requirement (mm) 1205 13.72 6.25 6.25
美规/墨西哥规插脚尺寸要求之一
尺寸没有标明公差的数字以±0.005为公差,所有单位均为inch; 标注角度的地方没有注明公差的以±1度为公差;
美规/墨西哥规插脚尺寸要求之二
尺寸没有标明公差的数字以±0.005为公差,所有单位均为inch; 标注角度的地方没有注明公差的以±1度为公差;
韩规插脚尺寸要求之一
课堂公约
请将手机调整至静音状态 积极回应、大胆参与
我们将要掌握的内容
一般常用有哪些插脚方式 各种插脚方式的尺寸要求如何
我们将要掌握的内容
一般插脚方式
欧规、英规、美规、韩规、日规、中 规、澳规、阿规共八种
欧规插脚尺寸要求之一
欧规插脚尺寸要求之二
英规插脚尺寸要求之一
英规插脚尺寸要求之二
韩规插脚尺寸要求之二
日规插脚尺寸要求之一
日规插脚尺寸要求之二
日规插脚尺寸要求之三
日规插脚尺寸要求之四
中规插脚尺寸要求之一
中规插脚尺寸要求之二
Symbol
A B C D
Requirement (mm)
1.4 ~ 1.5 6.18 ~ 6.4 12.565 ~ 12.835 15.65 ~ 16.35

世界各国电源插座标准

世界各国电源插座标准

世界各国电源插座标准电源插座标准是各个国家用于统一电器插头和插座设计的规范。

每个国家或地区拥有自己独特的电源插座标准和规范,这是因为不同国家的电力系统、电压、频率以及安全标准等方面存在差异。

以下是一些国际常见的电源插座标准,包括欧洲、北美、亚洲和澳洲:欧洲电源插座标准:1. 德国和奥地利:德国和奥地利采用的是Schuko插座标准,也称为德国标准插座,具有两个圆柱形针脚和一个地线。

2. 英国:英国采用的是英国标准插座,插头具有三个矩形针脚和一个地线,常称为13A插座。

3. 法国:法国采用的是法国标准插座,具有两个圆形针脚和一个地线,另外还有个带安全开关的插座设计。

4. 欧洲其他国家:欧洲大部分国家采用的是CEE 7/4和CEE7/7两种插座标准,这两种标准分别是地面插口和墙壁插座。

北美电源插座标准:1. 美国和加拿大:美国和加拿大采用的是NEMA电源插座标准,常见的插座类型有NEMA 1-15(两个扁平针脚)、NEMA 5-15(两个扁平针脚和一个地线)和NEMA 6-15(两个圆形针脚和一个地线)。

2. 墨西哥:墨西哥采用的是NEMA电源插座标准,与美国相同或相似。

亚洲电源插座标准:1. 中国:中国采用的是国家标准插座,通用插座为三个扁平针脚和两个圆形针脚。

国家还规定了多种安全插座标准,如三插二孔、三插三孔、五插二孔等。

2. 日本:日本采用的是JIS电源插座标准,有两个扁平针脚和一个地线。

澳洲电源插座标准:1. 澳洲:澳大利亚采用的是AS/NZS电源插座标准,常见的插座类型有Three-Flat-Pins(三个扁平针脚)、Two-Flat-Pins (两个扁平针脚)和Two-Slanted-Pins(两个带有角度的针脚)。

这只是世界各国电源插座标准的一小部分,还有其他许多国家拥有独特的标准。

当旅行到不同国家时,了解该国家的电源插座标准是很重要的,以确保电器能够正确连接和使用,并且避免安全隐患。

插座转换器或万用插头可以帮助解决不同标准之间的兼容性问题。

各国插脚安规尺寸标准

各国插脚安规尺寸标准

巴西 2PIN插脚 BLJ认证胶壳 (figure 13. NBR 14136: 2002)
印度插脚:
Indian Plug Checking Worksheet 标准:IS1293
Dimension: mm
Rated Current
Symbol
( ) 6A
( ) 16A
A
22.22±0.15
Symbol Requirement (mm)
H
1205
I
13.720.1
J
6.250.1
K
6.250.1
L
1.550.07
M
18.20.2
N
Marking of
N
neutral with N
沙特插脚: SASO Plug Checking Form according to Figure 1 of SASO 2203
修订记录
2013-10-15修改:
1、 GB1002-2008版 CCC插脚(厚1.4-1.5mm)增加插头插销离边沿的距离不小于6.5mm。 2、 增加日规插脚安规尺寸图表,日规插脚(厚1.4-1.6mm)备注“L"的尺寸要求不大于0.9mm,
及插头插销离边沿的距离不小于5.1mm。 3、 修改美规插脚安规尺寸,美规插脚(厚1.40-1.65mm),备注插头插销离边沿的距离不小于5.1mm.。 4、 插脚图示缩小
2PIN欧洲插脚 Two-pin plugs f (Up to 2.5 A rating) EN50075/IEC60083 - C5/CEE7/DIN49464
P 4.0,Q 18.0 ,I:金属下部结合部分边缘应光滑钝化,不得尖锐刺手. 此插脚适应国家包括:德国,俄罗斯,以色列

各国插头安规标准尺寸

各国插头安规标准尺寸

各国插头安规标准尺寸1.欧洲插头安规标准尺寸:欧洲插头采用的是欧洲标准插头(European Plug),其安规标准尺寸一般为:-两脚间距离:19毫米-地线脚直径:4毫米-具体国家间的插头尺寸可能会有所差异,但绝大多数国家都采用这一标准尺寸。

2.美国插头安规标准尺寸:美国插头采用的是美国标准插头(American Plug),其安规标准尺寸一般为:-两脚间距离:12.7毫米-地线脚直径:4毫米-美国插头通常还有一个额外的插孔用于接地,该插孔直径为6毫米。

3.英国插头安规标准尺寸:英国插头采用的是英国标准插头(British Plug),其安规标准尺寸一般为:-两脚间距离:22毫米-地线脚直径:6毫米-英国插头在设计上考虑了安全性,采用了可分离式插头和插座,以减少电器在插头未完全插入时的触电风险。

4.中国插头安规标准尺寸:中国插头采用的是中国标准插头(Chinese Plug),其安规标准尺寸一般为:-两脚间距离:18毫米-地线脚直径:4毫米-中国插头通常还有两个额外的插孔用于接地,这些插孔直径为4.8毫米。

5.日本插头安规标准尺寸:日本插头采用的是日本标准插头(Japanese Plug)-两脚间距离:15毫米-地线脚直径:4毫米-日本插头在设计上考虑了安全性和便携性,插头和插座都比较小巧。

需要注意的是,虽然各国插头的尺寸有所差异,但是现在市场上很多电器都配备了可调节插头,可以适用于不同国家的插座。

此外,还有一些插头适配器可以用于将不同国家插头转换为所需的插头类型。

使用这些适配器或可调节插头可以方便地将电器连接到不同国家的插座上。

各国插脚尺寸

各国插脚尺寸

2PIN欧洲插脚Two-pin plugs for class II appliances (Up to 2.5 A rating) According to EN50075 - Standard Sheet and IEC60083 - Standard C5Symbol Requirement(mm) Measured (mm) Symbol Requirement(mm)Measured (mm)A ≥ 16.5 I −B 25.6 - 26.6 J 3.94 – 4.06C 45 ︒K 10.0 – 11.0D R 5.0 – 6.0 L 18.5 – 19.5E 34.6 – 36.0 M ≤ 90 ︒F 13.0 – 14.4 N 0.7 – 1.7G Engagement18.0 – 19.2O ≤ 2.0G End 17.0 – 18.0 P ≥ 4.0H Within 4 mm fromengagementface≤ 4.0mmQ ≥ 18.0Above 4 mm fromengagementface≤ 3.8mmA & P only for plug with supply cord. Direct plug-in product not consider the dimensions.UK Plug Checking Form according to Figure 4 of BS1363-3Symbol Requirement(mm) Measured (mm) Symbol Requirement(mm)Measured (mm)A 25.37 max. Q 17.2-18.2B 25.37 max. R 6.22-6.48 /C 34.6 max. S 3.90-4.05D 11.05-11.18 T 6.22-6.48 /E 11.05-11.18 U 6.35 min.F R 15 min. -- V 60︒-80︒--G R 9.5 min. W 1.35-1.85H R 9.5 min. X 3.90-4.05I 22.10-22.36 Y 1.2-2.0J 22.23-23.23 Z R 0.1-1.0 -- K 1.35-1.85 a 58︒-62︒-- L 7.80-8.05 b 1.35-1.85M 58︒-62︒-- c 58︒-62︒-- N 3.90-4.05 / d 1.35-1.85O 9.2 max. e 0.2 max.P 9.5 max. f 1.35-1.85Grounding pinStandard sheet Figure 2.1 (a1) or 2.1(c)Standard sheet Figure 2.1 (e) and fig 2.4Position Required (mm) By Measurement (mm)By the gauges in Figure A1A 6.35±0.15 -B 6.35±0.15C +0.150.051.63-- D 7.92 -- P E 10.31 -- P F 17.06±0.4 - G 19.94±0.8 1 21.9 max. or 27.0 min. - 2 21.9 max. or 27.0 min. - 3 21.9 max. or 27.0 min. - 4 21.9 max. or 27.0 min.- 5 60︒ -- P 6 60︒ -- P 7 8.6 min. - 8 21.0 max. - 9 20.0±1.0 - 10 1.0 max - 118.7±0.5-Dimensions checked by gauge and measurementStandard sheet Figure 2.1Position Required (mm) By Measurement (mm) By the gauges in Figure A1 Plug type (h)R 0.35±0.05 -S 0.9±0.1 -T ≥0.60-V 6 -- PDimension Checking for Two-pin plugs of NA (15 A, 125 V)According to (NEMA WD 6-2002 Figure 1-15)Symbol Requirement (inch) Measured (inch) Symbol Requirement (inch) Measured (inch)A 0.120 - 0.130 E 0.240 - 0.260B 0.151- 0.161 F 0.307 - 0.322C 0.449 - 0.479 G 0.055 - 0.065D 0.625 - 0.718 H 0.495 - 0.505Perimeter faces to the plug blades shall not be less than 7.9 mm (intended for use withchildren’s toys) or 5.1 mm from any point of either bladeDimension Checking for Tow-pin plugs (6 A, 10 A rating)According to Fig 1 of GB 1002-2008Symbol Requirement (mm) Measured (mm) t 1.40 ~ 1.50b 6.18 ~ 6.40F 12.565 ~ 12.835E 15.65 ~ 16.35R 5.00 ~ 7.00dThis distance of live plug to engage edge ≥ 6.5dDimension Checking for Korea plugs (Two-pole plug for 3A250V) According to KSC 8305日本插脚Dimensions checked by gauge and measurementPosition Required (mm) By Measurement (mm)A <14.6B >10.8C 1.35 – 1.65D 1.35 – 1.65E -- --F -- --G 6.0 – 6.6H 6.0 – 6.6I -- --J -- --K 15.7 – 18.3L 15.7 – 18.3M -- --N -- --O -- --P 11.3 – 12.1Q 11.3 – 12.1R φ2.8 –φ3.3S >φ3.5T <0.9巴西插脚Equipment’s combined with two-pole plug (Class II) 10 A/250V a.c. (figure 13. NBR 14136: 2002)Symbol Requirement (mm) Measured (mm) Symbol Requirement (mm) Measured (mm)B 25.5 - 26.5 J 3.95 – 4.05C 90 ︒ - 92 ︒ K 10.0 – 11.0D R 5.0 – 6.0 L 19.0 – 19.7E 35.0 – 36.0 N 1.0 max.F 13.0 – 14.4 O R 2.0 -2.5G 18.8 – 19.2 ④> 3 mm①> 14 mm ⑤See above②See above ⑥See above③See above ⑦See aboveNote:1 The sketches are not intended to govern design, except as regards the dimensions shown2 Plugs can be rewirable or non-rewirableRequirements:①– The distance between the engagement face and the cord or cord guard, if any, shall be at least 14 mm②– Within this distance, the outline shall be not smaller than the engagement face.③– Within this distance, the outline shall be not larger than the engagement face.④– Insulating sleeves on the current-carrying pins are optional If the insulating sleeves are separate parts, they shall enter the plug by at least 3mm measured from the engagement face.⑤– The external diameter of the insulating sleeves shall not be larger than the diameter of the uninsulated part of the pins.⑥– To avoid damage to shutters, the ends of the pins shall show neither sharp edges nor burrs. They shall⑦– The angle of 90° represents the maximum permissible area for the orientation of the entry of the flexible cable or cord.印度插脚:Indian Plug Checking WorksheetDimension: mmSymbolRated CurrentMeasured ( ) 6A ( ) 16AA 22.22±0.15 28.6±0.15B 19.1±0.15 25.4±0.15C 7.010-7.085 8.660-8.735D 5.030-5.105 7.010-7.085E 15.77-16.94 20.47-21.64F 20.47-21.64 28.47-29.64G1) ≥7.94 ≥9.52 Note:1. “G” is the minimum distance between the pins and the perip hery of the plug.阿根廷插脚:IRAM 2063 Plug (Class II, two-pole) Checking Worksheet (IRAM 2063:1982 + Amd 1999)Symbol Requirement (mm) Measured (mm) Symbol Requirement (mm) Measured (mm)A 8.0 min. H 120±5︒B 7.92±0.1 I 13.72±0.1C 7.92±0.1 J 6.25±0.1D 6.86±0.1 K 6.25±0.1E 6.86±0.1 L 1.55±0.07F 60︒M 18.2±0.2G 60︒N Marked “N”Yes / No沙特插脚:SASO Plug Checking Form according to Figure 1 of SASO 2203。

世界各国电源插座标准

世界各国电源插座标准

世界各国电源插座标准世界各国之间存在着多种不同的电源插座标准,这些标准涉及到插座形状、插头大小、插入方式以及电源电压等方面。

下面将就几个主要的国际电源插座标准进行介绍。

1.美国标准(美洲、加拿大等地):美国标准电源插座主要有两种类型:Type A和Type B。

TypeA为两穗直角插座,Type B为两穗圆形插座,两者均为120V。

2.欧洲标准(包括大部分欧洲国家及中国香港等地):欧洲标准电源插座主要有两种类型:Type C和Type F。

TypeC为两穗圆形插座,Type F为两穗圆形插座(加地线)。

3.英国标准(英国、爱尔兰等地):英国标准电源插座为Type G,其特点是三个方形插座孔,其中一个为放置地线,电压为230V。

4.澳大利亚标准(澳大利亚、新西兰等地):澳大利亚标准电源插座为Type I,其特点是三个斜方形插座孔,另外还有一个中间的地线插孔,电压为230V。

5.中国标准:中国标准电源插座主要有两种类型:Type A和Type I。

TypeA为两穗直角插座,Type I为三个斜方形插座孔,另外还有一个中间的地线插孔,电压为220V。

除了上述国家和地区的标准插座,还有许多其他国家和地区采用的特殊标准插座,例如巴西的Type N、南非的Type M等等。

因此,在国际旅行或者国际贸易活动中,需要根据不同的目的地来准备适配器或者万能插头以满足不同插座标准的需求。

在旅行或者贸易活动中,准备适当的国际电源插头适配器是非常重要的。

否则,就可能无法连接电器设备,导致电源无法使用或者设备受到损坏。

因此,建议在出国前提前了解目的地的电源插座标准,并准备相应的适配器,以确保能够安全、有效地使用电源设备。

总结起来,不同国家和地区之间存在多种不同的电源插座标准,涉及到插座形状、插头大小、插入方式以及电源电压等方面。

了解各个国家和地区的标准电源插座,并准备相应的适配器,可以确保能够在国际旅行或者贸易中有效地使用电源设备。

各国插头标准汇总

各国插头标准汇总

.1 主要国家(地区)的电源电压和电源线插头形式主要国家(地区)的电源电压和电源线插头形式是在Q/FSX 10235的基础上加以补充见附录A,根据进口国或合同要求在具体产品标准中规定。

2 主要国家(地区)的电源线插头图形2.1 主要国家(地区)的电源线插头图形见附录B,根据进口国或合同要求选择使用。

2.2 各个国家(地区)的标准对电源线插头的绝缘尺寸有相应的要求,但对外形和颜色没有强制要求,不同的生产厂家其产品外形可能有所不同,插头的颜色可根据客户的要求进行选择,故附录B中的电源线插头图形不是唯一的选择。

2.3 选择电源线插头时,要考虑到进口国对电源线插头取得市场准入认证的要求。

2.4 电源线插头适用设备类型a) Ⅱ类设备:是指其防触电不仅依靠基本绝缘而且采用诸如双重绝缘或加强绝缘之类的附加安全措施的设备,俗称非接地设备。

b) Ⅰ类设备:是指其防触电不仅依靠基本绝缘而且采用附加安全措施的设备,俗称接地设备。

.主要国家(地区)的电源电压和电源线插头型式..........附 录 A电源线插头图形图1图2图3图4图5国家(地区):BRAZIL(巴西)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: NBR 6147和NBR 14136-Figure 9A额 定 值: 10 A 250 V国家(地区):ARGENTINA(阿根廷)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: IRAM 2063 额 定 值: 10 A 250 V国家(地区):AUSTRALIA(澳大利亚)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: AS/NZS 3112:2000 额 定 值: 7.5 A 或10 A 250 V国家(地区):AUSTRALIA(澳大利亚)名 称: 二极带接地电源线插头[适用Ⅰ类(Ⅱ)类设备] 采用标准: AS/NZS 3112:2000额 定 值: 10 A 250 V国家(地区):ARGENTINA(阿根廷)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: IRAM 2073 额 定 值: 10 A 250 V图6图7图8图9图10图11国家(地区):BRAZIL(巴西)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: NBR 6147和Std Sht IEC 60083/75-6C 额 定 值: 16 A 250 V国家(地区):BRAZIL(巴西)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: NBR 6147额 定 值: 15 A 125 V 或250 V国家(地区):BRAZIL(巴西)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: NBR 6147和NBR 14136-Figure 4A 额 定 值: 10 A 250 V国家(地区):BRAZIL(巴西)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: NBR 6147额 定 值: 15 A 125 V 或250 V国家(地区):CHINA(中国)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: GB 2099.1和GB 1002 额 定 值: 6 A 和10 A 250 V国家(地区):CHINA(中国)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: GB 2099.1和GB 1002 额 定 值: 6 A 和10 A 250 V图12图13图14图15图16图17国家(地区):CHINA(中国)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: GB 2099.1和GB 1002 额 定 值: 6 A 和10 A 250 V国家(地区):DENMARK (丹麦)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: IEC 60884-1和SB 107-2-DI(Std.Sht.DK2-5A) 额 定 值: 10 A 250 V国家(地区):EUROPE(欧洲)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: EN 50075 额 定 值: 2.5 A 250 V国家(地区):EUROPE(欧洲)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: CEE 7(Std.Sht.XVII)和IEC 60884-1 额 定 值: 10 A 和16 A 250 V国家(地区):EUROPE(欧洲)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: CEE 7(Std.Sht.VII)和IEC 60884-1 额 定 值: 16 A 250 V国家(地区):EUROPE(欧洲)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: CEE 7(Std.Sht.VII)和IEC 60884-1 额 定 值: 16 A 250 V图18图19图20图21图22图23国家(地区):HONG KONG(香巷)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: BS546:1950 额 定 值: 15 A 250 V国家(地区):INDIA(印度)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: Design Reference to BS 4573 额 定 值: 2.5 A 250 V国家(地区):INDIA(印度)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: IS:6538-1971 额 定 值: 6 A 250 V国家(地区):INDIA(印度)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: IS:6538-1971 额 定 值: 16 A 250 V国家(地区):INDONESIA(印尼)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: Design Reference to KSC 8305 额 定 值: 10 A 250 V国家(地区):INDONESIA(印尼)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: Design Reference to GOST R 51322.1 额 定 值: 16 A 250 V图24图25图26图27图28图29国家(地区):INDONESIA(印尼)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: Design Reference to GOST R 51322.1 额 定 值: 16 A 250 V国家(地区):INDONESIA(印尼)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: SI 32 额 定 值: 16 A 250 V国家(地区):INDONESIA(印尼)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: SI 32 额 定 值: 16 A 250 V国家(地区):ITALY(意大利)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: CEI 23-50 额 定 值: 10 A 250 V国家(地区):ITALY(意大利)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: CEI 23-16(Expiry 2005) 额 定 值: 10 A 250 V国家(地区):ITALY(意大利)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: CEI 23-50 额 定 值: 10 A 250 V图30图31图32图33图34国家(地区):ITALY(意大利)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: CEI 23-16(Expiry 2005) 额 定 值: 10 A 250 V国家(地区):JAPAN(日本)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: JIS C8303和JIS C8306额 定 值: 3 A ~7 A/125 V 和7 A ~15 A 125 V国家(地区):JAPAN(日本)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: UL498,UL817,CSA Std C22.2,JIS C8303和JIS C8306额 定 值: 3 A ~75 A/125 V 和7 A ~15 A 125 V国家(地区):JAPAN(日本)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: JIS C8303和JIS C8306额 定 值: 3 A ~75 A/125 V 和7 A ~15 A 125 V国家(地区):KOREA(韩国)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: KSC 8305 额 定 值: 3 A 250 V国家(地区):KOREA(韩国)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: KSC 8305额 定 值: 3 A 250 V for 0.50 mm27 A 250 V for 0.75 mm 212 A 250 V for 1.25 mm 215 A 250 V for 2.00 mm 2图36图37图38图39图40国家(地区):KOREA(韩国)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: KSC 8305额 定 值: 3 A 250 V for 0.50 mm27 A 250 V for 0.75 mm210 A 250 V for 1.00 mm 212 A 250 V for 1.25 mm 215 A 250 V for 2.00 mm 2国家(地区):KOREA(韩国)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: KSC 8305额 定 值: 3 A 250 V for 0.50 mm27 A 250 V for 0.75 mm 210 A 250 V for 1.00 mm212 A 250 V for 1.25 mm 215 A 250 V for 2.00 mm 2国家(地区):MALAYSIA(马来西亚)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: Compliance Test to MS 589:Part 1:1997额 定 值: 6 A 250 V for 0.75 mm 210 A 250 V for 1.00 mm213 A 250 V for 1.25 mm 2 and 1.50 mm 2国家(地区):RUSSIA(俄罗斯)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: GOST R 51322.1 额 定 值: 16 A 250 V国家(地区):RUSSIA(俄罗斯)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: GOST R 51322.1 额 定 值: 16 A 250 V国家(地区):SINGAPORE(新加波)名 称: 二极带接地电源线插头[适用Ⅰ(Ⅱ)类设备] 采用标准: SS145/A额 定 值: 3 A 250 V for 0.50 mm 26 A(10 A*) 250 V for 0.75 mm210 A 250 V for 1.00 mm213 A 250 V for 1.50 mm 2图42图43图44图45图46图47国家(地区):SINGAPORE(新加波)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: SS472:1999 and selected clause of SS241:1996 额 定 值: 15 A 250 V国家(地区):SOUTH AFRICA(南非)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: Compliance Test to SABS 164-1 额 定 值: 16 A 250 V国家(地区):SWITZERLAND(瑞士)名 称: 二极电源线插头(适用Ⅱ类设备)采用标准: IEC 60884-1,SEV 1011,SEV 6533-2 Type 11 额 定 值: 10 A 250 V国家(地区):SWITZERLAND(瑞士)名 称: 二极电源线插头(适用Ⅱ类设备)采用标准: IEC 60884-1,SEV 1011,SEV 6533-2 Type 11 额 定 值: 10 A 250 V国家(地区):SWITZERLAND(瑞士)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: IEC 60884-1,SEV 1011,SEV 6533-2 Type 11 额 定 值: 10 A 250 V国家(地区):TAIWAN(台湾)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: CNS 101917-2额 定 值: 7 A 125 V for 0.75 mm211 A 125 V for 1.25 mm215 A 125 V for 2.00 mm 2图48图49图50图51图52国家(地区):TAIWAN(台湾)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: CNS 101917-2额 定 值: 7 A 125 V for 0.75 mm211 A 125 V for 1.25 mm215 A 125 V for 2.00 mm 2国家(地区):U.K.(英国)名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: BS 4573 额 定 值: 2.5 A 250 V国家(地区):U.K.(英国)名 称: 二极电源线带保险丝插头(适用Ⅱ类设备) 采用标准: BS 1363/A by ASTA 额 定 值: 3 A 250 V for 0.50 mm26 A 250 V for 0.75 mm 2国家(地区):U.K.(英国)名 称: 二极带接地电源线带保险丝插头[适用Ⅰ(Ⅱ)类设备]采用标准: BS 1363/A and Std.122 by ASTA 额 定 值: 6 A 250 V for 0.75 mm210 A 250 V for 1.00 mm 2国家(地区): :U.S.A.(美国)和CANADA(加拿大) 名 称: 二极电源线插头(适用Ⅱ类设备) 采用标准: UL498,UL817,CSA Std C22.2 额 定 值: 10 A 125 V for AWG 1813 A 125 V for AWG 16 线材要求为双绝缘结构国家(地区): :U.S.A.(美国)名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: UL498,UL817,CSA Std C22.2额 定 值: 10 A 125 V for AWG 1812 A 125 V for AWG 17 13 A 125 V for AWG 16图54国家(地区): :U.S.A.(美国)和CANADA(加拿大) 名 称: 二极带接地电源线插头(适用Ⅰ类设备) 采用标准: UL498,UL817,CSA Std C22.2 额 定 值: 10 A 125 V for AWG 18。