浊度计说明书

合集下载

TSS浊度计使用说明书

TSS浊度计使用说明书
第 2 章 安 装 ............................................................................................................3
2.1 安装说明......................................................................................................... 3 2.2 变送器的安装................................................................................................. 3 2.3 传感器的安装................................................................................................. 4 2.4 电气连接......................................................................................................... 8
第 3 章 操 作 ..........................................................................................................12
3.1 操作界面....................................................................................................... 12 3.2 菜单总体结构............................................................................................... 13 3.3 常规设置流程............................................................................................... 14 3.4 菜单详细介绍............................................................................................... 15

浊度检测仪使用说明书

浊度检测仪使用说明书

濁度檢測儀使用說明書使用之前請仔細閱讀說明書!在线浊度仪一、测量原理ZD 系列浊度测量仪,中、低浊度范围内(小于10NTU 为低浊度,11-100NTU 为中浊度,大于100NTU 为高浊度)采用90°散射光原理。

光路原理如下图:Io ——入射光 It ——透射光 Is ——散射光 D ——溶液浑浊度一束特定光谱的平行光通过溶液时,一部分被吸收和散射,一部分透过溶液。

与入射光成90°方向的散射光的强度符合雷莱公式:Is=KNV 2Io入4Io ——入射光强度 Is ——散射光强度 N ——单位溶液微粒数 V ——微粒体积 入——入射光波长 K ——系数在入射光恒定的条件下,在一定浊度范围内,散射光强度和溶液的浑浊度成正比。

上式可整理改写为:Is =K ´N(K ´表示常数)Io根据这一公式,我们可以通过测定水样中微粒的散射光强度来测量水样的浑浊度。

这是本产品的基本测量原理。

DZ 系列浊度仪高浊度测量采用的是散射和透射结合型原理。

二、基本电路方框图散射光结构仪器工作原理图透射光结构仪器工作原理图光电传感器由光源、透镜、光电元件等组成,当光线通过被测液样时,与入射光成90°方向的散射光作用于光电元件,产生了随浊度变化的电信号,该信号与基准信号一起送入信号处理器。

信号处理器以集成电路为核心,构成性能稳定的电子线路,对信号进行放大、滤波、运算、补偿等处理,使其在整个测量范围内与被测液样的浊度成线性关系。

稳压电源由变压器、整流器、滤波器、稳压模块等组成,将200伏至240伏范围内变化的交流电变换成仪器所需要的直流工作电压。

三、结构图1、浊度传感器2、进水口3、出水口4、溢流口5、排气口6、电源220伏7、信号输出8、校准电位器9、浊度显示仪表10、信号输出11、浊度显示面板1 2、挂钩 13、电源220伏浊度传感器是本仪器的关键部位,内装光电转换器件、集成电路板、不锈钢水箱等,对其更加爱护和保养。

HACH2100N中文说明书

HACH2100N中文说明书

HACH 2100 N 型实验室浊度计使用说明手册(用软件 1 版)一九九七.六HACH 2100 N 型实验室浊度计使用说明(用软件 1 版)目录操作页1 概述1.1 仪器介绍1.2 规定的随机附件1.3 工作原理1.4 使用前的准备1.4.1 开箱1.4.2 工作环境1.4.3 工作电源选用2 浊度测量2.1 操作控制和指示2.2 测量浊度2.2.1 步骤2.2.2 备忘录2.3 测量技术2.3.1 清洗样品管2.3.2 应用硅油2.3.2.1用硅油的步骤2.3.3 制备稀释水2.3.4 标志和样品管配套2.3.4.1标志单支样品管2.3.4.2样品管配套2.3.5 去除汽泡(脱气)2.3.5.1用真空2.3.5.2加表面活性剂2.3.5.3用超声波浴槽2.3.5.4用加热2.3.6 信号平均2.3.7 测量超量程样品2.3.8 样品稀释2.3.8.1用样品管配件2.3.8.1.1安装与拆下样品管配件 2.3.9 冷凝(结雾)2.3.10 校核2.3.11 有代表性采集样品3 操作3.1 操作控制和指示3.1.1 RANGE 键使用3.1.2 UNITS Exit 键使用3.1.3 SIGNAL AVG 键使用3.1.4 RA710 键使用3.1.5 PRINT 键使用3.1.6 CAL 键使用3.1.7 ENTER 键使用3.1.8 Arrow 键使用3.1.9 报警音键(信号音)3.2 标定3.2.1 Formazin 贮备液3.2.2 稀释水3.2.3 制备推荐的 Formazin 稀液3.2.4 用 Formazin 标定 2100N 浊度计 3.2.4.1复查标定序列3.2.5 Gelex 二级浊度标准的使用3.2.6 配制 Formazin 贮备液3.3 特别研究的应用(不推荐)3.3.1 扣去稀释水浊度3.3.2 编辑标定数据点3.3.3 制备用户自选的 Formazin 稀液3.3.4 用用户自选标准标定 2100N 浊度计装置 / 维护4 空气清洗系统4.1 连接空气清洗5 流通样品管套件的使用6 数据输出7 维护7.1 清洗7.2 换灯8 排除故障8.1 绪言8.2 错误信息8.3 诊断功能8.3.1 基本诊断码8.3.2 其他诊断8.3.2.1显示节和插图8.3.2.2冷起动8.3.2.3闪烁“9”8.3.2.4闪烁“0”9 零部件和附件更换10 维修服务11 规格12 担保1 概述1.1 仪器介绍Hach 2100N 型实验室浊度计(图1)是用于 0-4000 NTU (散射浊度单位)的浊度测量。

浊度计作业指导书

浊度计作业指导书

浊度计作业指导书一、引言浊度计是一种用于测量液体中悬浮颗粒物浓度的仪器。

本指导书旨在为使用浊度计进行测量的操作人员提供详细的指导,以确保测量结果的准确性和可靠性。

二、测量原理浊度是指液体中悬浮颗粒物的数量和大小,也是液体透明度的度量。

浊度计通过测量液体中光的散射来确定浊度值。

当光通过液体时,与悬浮颗粒物相互作用,使光线发生散射,浊度计通过测量散射光的强度来计算浊度值。

三、仪器准备1. 确保浊度计处于稳定的工作环境中,避免温度和湿度的变化对测量结果的影响。

2. 检查浊度计的电源是否正常,确保仪器能够正常启动。

3. 检查浊度计的光源和接收器是否干净,如有污垢应及时清洁。

4. 根据测量要求选择合适的测量单元,确保测量范围和灵敏度的匹配。

四、标定1. 打开浊度计,等待仪器稳定后进行标定。

2. 使用标准溶液进行浊度计的零点校准。

将标准溶液置于浊度计测量单元中,记录零点浊度值。

3. 使用已知浓度的标准溶液进行浊度计的定标。

将标准溶液置于浊度计测量单元中,记录定标浊度值。

4. 根据零点浊度值和定标浊度值,计算出浊度计的校准系数。

五、样品处理1. 根据测量要求,选择合适的样品处理方法。

常见的样品处理方法包括过滤、离心、稀释等。

2. 对于浑浊的样品,应先进行过滤处理,以去除大颗粒物的干扰。

3. 对于含有悬浮颗粒物较多的样品,应根据测量要求进行适当的稀释,以保证测量结果在仪器的测量范围内。

六、测量操作1. 将经过处理的样品置于浊度计测量单元中。

2. 确保浊度计处于稳定状态后,记录测量值。

3. 如需多次测量同一样品,应先将样品搅拌均匀,再进行测量,以确保结果的一致性。

4. 如需测量多个样品,应在每次测量前清洁浊度计测量单元,以避免样品之间的交叉污染。

七、数据处理1. 根据测量结果计算出样品的浊度值。

2. 如需将浊度值转换为悬浮颗粒物的浓度,应根据样品的特性和测量方法进行相应的计算。

3. 记录测量结果和计算过程,以备后续分析和比较。

昕瑞WGZ-2浊度计说明书

昕瑞WGZ-2浊度计说明书

一、概述WGZ系列浊度计(仪)是用于测量悬浮于水或透明液体中不溶性颗粒物质所产生的光的散射程度,并能定量表证这些悬浮颗粒物质的含量。

本仪器采用国际标准ISO7027中规定的福尔马肼(Formazine)浊度标准溶液进行标定,采用NTU作为浊度计量单位。

二、用途可以广泛应用于发电厂、纯净水厂、自来水厂、生活污水处理厂、饮料厂、环保部门、工业用水、制酒行业及制药行业、防疫部门、医院等部门的水样浊度测定。

三、仪器特点►微电脑,触摸式键盘,LCD背光液晶显示屏,串行RS232数据通讯接口,可选配外置或内置打印机。

►特制高强度长寿命光源,年、月、日时间显示,设有数据存储查询功能,可满足GLP需求►数据非线性处理及数据平滑功能,快速自动多点校正,自诊断信息提示,可选量程自动或人工切换►快捷设置平均测量模式,以最短的时间得到正确的数据,特别适用于极低浊度测量,可测不稳定水样►精确的光路系统,可靠的定位结构,有效的色度补偿,直读浊度值►可选光谱测量单元,多种测量模式,选配流动取样装置,可实现连续测量。

四、注意事项WGZ系列浊度计是光电相结合的精密计量仪器,操作前应仔细阅读使用说明书并通过正确操作才能获得精确的测量结果。

a、使用环境必须符合工作条件。

b、测量池内必须长时间清洁干燥、无灰尘,不用时须盖上遮光盖。

c、潮湿气候使用,必须相应延长开机时间。

d、被测溶液应沿试样瓶壁小心倒入,防止产生气泡,影响测量准确性。

e、更换试样瓶或经维修后须重新标定。

f、非专业维修工程师,请勿打开仪器进行维修。

五、工作条件a、环境温度使用5~40℃,储存-20~55℃;b、相对温度不大于90%RH无冷凝现象;c、电源电压220V±22V 频率50±1Hz,并且具有良好接地;d、仪器应水平放置在平稳的实验台上,有效的避开直射光线;e、仪器周围应留有足够的空间以利散热,且无强烈震动源及强磁场干扰;f、周围空气中应无明显灰尘及腐蚀性气体存在。

便携式浊度计使用手册

便携式浊度计使用手册

TN-100/T-100浊度仪使用手册目录1 概览................................................ ........................................ .11.1打开TN- 100 /T-100型浊度表表及其配件------------------------1 1.2 显示--------------------------------------------------------------21.3键盘及其功能------------------------------------------------------31.4电池安装---------------------------------------------------------42 浊度标定 (5)2.1校正标准---------------------------------------------------------52.2索引---------------------------------------------------------------52.3校准程序-------------------------------------------------------- 62.4恢复出厂设置---------------------------------------------------83 浊度测量............................................... .......... . (10)3.1基本资料--------------------------------------------------------103.2浊度测量程序--------------------------------------------------103.2.1样品瓶的制备------------------------------------------------113.2.2测量程序---------------------------------------------------123.3单次测量或连续测量----------------------------------------134故障排除指南............................................... ......... ……….... .155日常维护............................................... (16)5.1样品瓶的处理、清洁和护理---------------------------------166 配件................................................ ............................... .. (17)7 规格................................................ ........................... .. (18)8 附录1 :浊度............................................. . (19)8.1 定义-----------------------------------------------------------198.2为何重要?-----------------------------------------------------198.3测量原理-------------------------------------------------------198.4散射浊度单位(NTU)-------------------------------------208.5索引—样品瓶----------------------------------------------------209 附录2 :良好的测量技术指导 (21)9.1让小瓶中样品保持良好状态--------------------------------219.2样品与样品瓶的匹配-----------------------------------------219.3抽气--------------------------------------------------------------229.4及时采样--------------------------------------------------------229.5其他重要抽样技术--------------------------------------------229.6校准--------------------------------------------------------------239.7稀释--------------------------------------------------------------2310质保................................................ (24)11项目返回.............................................. .......................... . (24)1 概览感谢您选择防水便携式TN-100/T-100浊度仪。

西仪WGZ-2000浊度计使用说明书

西仪WGZ-2000浊度计使用说明书

WGZ-2000浊度计使用说明书上海精密科学仪器有限公司目次1.仪器的作用┈┈┈┈┈┈┈┈┈┈┈┈┈┈22.仪器的工作环境┈┈┈┈┈┈┈┈┈┈┈┈23.仪器的性能┈┈┈┈┈┈┈┈┈┈┈┈┈┈24.仪器的工作原理┈┈┈┈┈┈┈┈┈┈┈┈25.仪器的光学系统┈┈┈┈┈┈┈┈┈┈┈┈36.仪器的电路系统┈┈┈┈┈┈┈┈┈┈┈┈37.仪器的使用方法┈┈┈┈┈┈┈┈┈┈┈┈48.常见故障及处理方法┈┈┈┈┈┈┈┈┈┈69.仪器成套性┈┈┈┈┈┈┈┈┈┈┈┈┈┈710.售后服务及承诺┈┈┈┈┈┈┈┈┈┈┈┈7附录1┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈8附录2┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈9附录3┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈┈11本产品根据上海精密科学仪器有限公司企业标准《WGZ-2000浊度计》生产生产许可证证号:沪制01040048号1.仪器的作用WGZ-2000型浊度计可用于测量悬浮于水(或透明液体)中不溶性颗粒物质所产生的光的散射或衰减程度,并能定量表征这些悬浮颗粒物质含量的仪器。

该仪器可广泛用于水厂、食品、化工、电厂、冶金环保及制药行业等部门,是常用的实验室仪器。

2.仪器的工作环境1.环境温度:5℃~35℃2.相对湿度:不大于85%3.使用时放置在坚固的平稳的工作台上,且避免震动。

4.尽量远离高强度的磁场、电场及发生高频波的电器设备。

5.避免高温接近仪器。

6.供给仪器的电源为220V±22V,50Hz±1Hz,并必须装有良好接地线。

3.仪器的性能1.光源:钨卤素灯6V、12W2.接收元件:硅光电池3.测量范围NTU:0.00—19.99;20.0—199.9;200—2000(量程自动切换)4.读数显示方法:四位LED数字显示5.仪器线性误差:3%FS6.示值允许误差:≤±5%7.样品瓶:φ25mm×95mm8.样品容积:20ml~30ml9.质量:8kg10.外型尺寸:358mm×323mm×160mm(1×b×h)11.熔断器:RF1-201A250V4.仪器的工作原理WGZ-2000型浊度计的基本原理是当光通过装有悬浮样品的样品瓶时,产生的90º散射光信号与前向透射光和前向散射光信号的和之比随浊度大小而变化,即:90º散射信号(前向透射+前向散射)信号仪器的光学和电路根据以上原理而设计。

水质浊度计使用方法说明书

水质浊度计使用方法说明书

水质浊度计使用方法说明书一、产品概述水质浊度计是一种用于测量水体浊度的仪器。

浊度是指水中悬浮颗粒物的浓度,是评估水质清澈程度的重要指标。

本产品具有测量快速、准确度高等特点,适用于环境监测、水质评估、工业生产等多个领域。

二、产品结构和外观水质浊度计主要由仪器主体和显示屏组成。

仪器主体具有测量窗口,内部装有浊度测量模块和数据处理模块。

显示屏可以显示测量结果和其他相关信息。

三、使用前准备1. 确保水质浊度计电量充足,如电池电量不足应及时更换。

2. 清洁测量窗口,确保表面干净无污染物。

3. 打开仪器主体开关,并等待仪器启动完成。

四、测量操作步骤1. 将水质浊度计测量窗口放入待测水体中,确保与水体充分接触。

2. 点击显示屏上的测量按钮,开始自动测量。

3. 等待测量完成,显示屏将显示出浊度数值和测量结果。

4. 按需保存数据或进行其他操作。

五、注意事项1. 使用时请确保仪器主体与水体充分接触,以保证测量的准确性。

2. 测量过程中,请勿移动或震动测量仪器,避免测量结果受到干扰。

3. 使用后请及时清洁测量窗口,防止残留污染物对下次测量的影响。

4. 请勿将水质浊度计暴露在极高或极低温度环境中,以免损坏仪器。

5. 如发现仪器异常情况,请及时联系售后服务。

六、维护与保养1. 定期清洁测量窗口,可使用干净的软布轻轻擦拭。

2. 长时间不使用时,建议关闭电源并储存于干燥通风的环境中。

3. 如需更换电池,请参照产品说明书进行操作。

七、故障排除1. 若测量结果出现异常,请检查测量窗口是否干净,并确保测量操作正确。

2. 如仍无法解决问题,请联系售后服务。

八、技术规格1. 测量范围:0-1000 NTU(浊度单位)2. 测量精度:±2% FS3. 工作温度:5-40°C4. 供电方式:内置电池,可连续工作10小时5. 产品尺寸:XXmm × XXmm × XXmm6. 产品重量:XXg注:NTU为浊度单位,FS为满量程。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

上海悦丰浊度仪SGZ-200A
用途
SGZ系列数显浊度仪是用于测量悬浮于水或透明液体中不溶性颗粒物质所产生的光的散射程度,并能定量表证这些悬浮颗粒物质的含量。

本仪器采用国际标准ISO7027中规定的福尔马肼(Formazine)浊度标准溶液进行标定,采用NTU作为浊度计量单位。

可以广泛应用于发电厂、自来水厂、生活污水处理厂、饮料厂、环保部门、工业用水、制酒行业及制药行业、防疫、医院等部门的浊度测定。

仪器特点
流线型外形设计,美观的国际流行雪花漆表面,将更适合现代实验室环境。

宽大明亮的LCD液晶显示屏,使读数更为舒适,且不受自然光的影响。

简洁的操作及其宽广的测量范围与较高的性价比,更能适合于各行业使用。

独特的定位结构及其高精度的光路系统,有效的保证仪器能长时间稳定工作。

精确的量程自动切换装置,及其可靠的线性补偿系统,使得测量数据更准确,稳定性更好。

增加了色度补偿系统,有效的避免试样颜色引起的干扰,能正确反映浊度的概念。

上海悦丰浊度仪SGZ-20A
技术参数介绍:
技术参数Specifications
用途
SGZ型数显浊度仪是用于测量悬浮于水或透明液体中不溶性颗粒物质所产生的光的散射程度,并能定量表征这些悬浮颗粒物质的含量。

本仪器采用国际标准ISO7027中规定的福尔马肼(Formazine)浊度标准溶液进行标定,采用NTU作为浊度计量单位。

可以广泛应用于发电厂、自来水厂、生活污水处理厂、饮料厂、环保部门、工业用水、制酒行业及制药行业、防疫部门、医院等部门的浊度测定。

仪器特点
采用LCD带背光的液晶显示屏,使读数更为舒适,且不受自然光的影响。

简洁的操作及适量的测量范围与较高的性价比,更能适合于各行业使用。

独特的定位结构及高精度的光路系统,有效保证测量值的正确性及重复性。

采用低漂移、高精度、稳定性好的电路系统,及高效长寿命光源,可有效保证仪器长时间稳定工作。

P型带RS232输出接口,连接电脑和打印机。

用户可根据需要可以选择不同的浊度单位。

相关文档
最新文档