SICK-PBS-压力传感器

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

Burst pressure 0.5 1 1 1.7 3.4 3.4 10 10
Pressure ranges 0…4 0…6 0…10 0…16 0…25 0…40 0…60
Pressure ranges 0…0.1 0…0.16 0…0.25 0…0.4
MPa MPa MPa MPa
Unit
MPa abs MPa abs MPa abs MPa abs Unit
Pressure ranges 0…1 0…1.6 0…2.5 0…4 0…6 0…10 0…16 0…25
Overpressure safety 2 3.2 5 8 12 20 32 50
Burst
Unit
MPa MPa MPa MPa MPa MPa MPa MPa
pressure
5
10
10
17
34
34
100
100
Pressure ranges 0…40 0…60 0…100 0…160 0…250 0…400 0…600
Pressure ranges 0…1 0…1.6 0…2.5 0…4
Unit
bar bar bar bar
bar abs bar abs bar abs bar abs
Starting from a smallest measurement range of 0…1 bar, there is a large number of measurement ranges available up to 600 bar. In addition, the PBS offers absolute and compound ranges. The zero point can be adjusted within a span of +3% of the measurement range. The PBS has a circularly welded stainless steel membrane. Hence, there are no internal sealing elements and it is well suited for a large variety even of corrosive media. The PBS is wear-free and does not require maintenance. As there is a large multitude of customary process connectors available as standard, no additional adapters are needed. For electrical connection the PBS has an M12x1 connector.
Overpressure safety 0.2 0.32 0.5 0.8
The PBS features the following functionalities: • Switching point and reset point
(Hysteresis) • Window function • Normally open or normally closed • Switching delay • Min/max memory • Password protection to prevent from
PBS
Technical Data
Configurations Unit
bar bar bar bar bar bar bar bar Unit
D atA S h ee t
PBS Electronic Pressure Switch with Display
PBS - electronic pressure switch, transmitter and display in one device.
Baidu Nhomakorabea
The pressure switch PBS is designed for pressure monitoring and measurement in liquid and gaseous media. The PBS is suited for general industrial applications such as machine and plant engineering, in machine tool systems, in hydraulic and pneumatic systems, for pressure monitoring and control and for pumps and compressors. It is pressure switch, transmitter and display in one and the same device. In its standard configuration it has two switching outputs (PNP or NPN). In addition, there are configurations available with one or two switching points and an analog output signal (4…20 mA or 0…10 V) as well as with IO-Link.
Overpressure safety 2 3.2 5 8
Burst pressure 5 10 10 17
Pressure ranges 0…6 0…10 0…16 0…25
Pressure ranges -1…0 -1…+1.5 -1…+3 -1…+5
Overpressure safety 2 3.2 8 8
Burst pressure 5 10 17 17
Pressure ranges -1…+9 -1…+15 -1…+24
Benefits
• Compact and robust design • Rotatable housing for flexible
installation • Safe and simple operation and
set-up with three large buttons and clearly legible display • Wide application range • Insensitive against corrosive media through hermetically sealed stainless steel membrane • Cost reduction through IO-Link
Pressure ranges 0…0.1 0…0.16 0…0.25 0…0.4 0…0.6 0…1 0…1.6 0…2.5
Overpressure safety 0.2 0.32 0.5 0.8 1.2 2 3.2 5
unintended misadjustment • Change over between pressure units
in display
Customer-specific parametrization at factory is available upon request. The intuitive setup using the three large buttons and the integrated display are according to the recommendation 24574-1 of the German engineering federation VDMA. The display and the electrical connector can be rotated against the process connector and against each other to allow well visible display orientation and clean cable routing.
相关文档
最新文档