CR1000 数据采集器

合集下载

CR1000X测量和控制数据记录仪快速入门指南说明书

CR1000X测量和控制数据记录仪快速入门指南说明书

CR1000X Measurement and Control DataloggerTable of Contents1. Getting started12. USB communications23. Testing communications with EZSetup44. Making the software connection65. Creating a Short Cut data logger program86. Sending a program to the data logger127. Working with data147.1 Default data tables147.2 Collecting data157.2.1 Collecting data using LoggerNet157.2.2 Collecting data using PC400167.3 Viewing historic data161. Getting startedGetting started provides a cursory view of data acquisition and walks you through a procedure to set up a simple system. You may not find it necessary to progress beyond this. However, should you want to dig deeper into the complexity of the data logger functions or quickly look for details, extensive information is available in the full CR1000X manual.This exercise guides you through the following steps:l Connecting the data logger to a computerl Attaching a sensor to the data loggerl Creating a program for the data logger to measure the sensorl Making a simple measurementl Storing measurement data on the data loggerl Collecting data from the data logger with a computerl Viewing real-time and historical data with a computerIn addition to your data logger, the following items are used in this exercise (many are shipped with your data logger and all are available on ):l Type T thermocouple, 4 to 5 inches long; one is shipped with the data loggerl Computer with a USB portl USB cablel Data logger support software such as LoggerNet or PC400 installed on your computerAdditional Campbell Scientific publications are available online at . Video tutorials a re available at /videos . Generally, if a particular feature of the data logger requires a peripheral hardware device, more information is available in the help or manual written for that device.2. USB communicationsSetting up a USB connection is a good way to begin communicating with your data logger. Because this connection does not require configuration (like an IP address), you need only set up the communications between your computer and the data logger. Use the following instructionsor watch the Quickstart videos at https:///videos.Follow these steps to get started. These settings can be revisited using the data logger support software Edit Datalogger Setup option .1. Using data logger support software, launch the EZSetup Wizard.l LoggerNet users, click Setup, select the View menu and ensure you are in the EZ(Simplified) view, then click Add Datalogger.l PC400 users, click Add Datalogger.2. Click Next.3. Select your data logger from the list. In the Datalogger Name field, type a meaningfulname for your data logger (for example, a site identifier or project name), and click Next.4. Select the Direct Connect connection type and click Next.5. If this is the first time connecting this computer to a CR1000X via USB, click InstallUSB Driver, select your data logger, click Install, and follow the prompts to install theUSB driver.6. Plug the data logger into your computer using a USB cable. The USB connection supplies5 V power as well as a communications link, which is adequate for setup. A 12 V battery willbe needed for field deployment. If using RS-232, external power must be provided to the data logger, and a CPI/RS-232 RJ45 to DB9 cable is required to connect to the computer.7. From the COM Port list, select the COM port used for your data logger. It will appear asCR1000X (COM number).8. USB connections do not typically require a COM Port Communication Delay; this type ofdelay allows time for hardware devices to "wake up" and negotiate a communications link.Accept the default value of 00 seconds and click Next.9. You must match the PakBus address hardware settings of your data logger. A USBconnection does not require a baud rate selection, keep the default. T he default PakBus address is 1.10. Set an Extra Response Time if you have a difficult or marginal connection and you want thedata logger support software to wait a certain amount of time before returning acommunications failure error. Accept the default value of 00 seconds.11. Set a Max Time On-Line to limit the amount of time the data logger remains connected.When the data logger is connected, communications with it are terminated when this time limit is exceeded. A value of 0 in this field indicates that there is no time limit formaintaining a connection to the data logger.12. Leave the Neighbor PakBus Address as the default of 0.13. Click Next.14. By default, the data logger does not use a security code or a PakBus encryption key.Therefore, the Security Code can be set to 0, and the PakBus Encryption Key can be left blank. If either setting has been changed, enter the new code or key.15. Click Next.16. Review the Setup Summary. If you need to make changes, click Previous to return to aprevious window and change the settings.17. Setup is now complete. The EZSetup Wizard allows you to Finish, or you may click Next totest communications, set the data logger clock, and send a program to the data logger.3. Testing communications with EZSetup1. Advance to, or select, t he Communication Test step in EZ Setup. See USB communications(p. 2) for more information.2. Ensure the data logger is physically connected to the computer, select Yes to testcommunications, then click Next to initiate the test.3. With a successful connection, the Connection Time w ith the data logger is displayed in thelower-left corner of the wizard. Click Next.4. The Datalogger Clock window displays the time for both the data logger and the computer(server).l The Adjusted Server Date/Time displays the current reading of the clock for the computer running your data logger support software. If the Datalogger Date/Timeand Adjusted Server Date/Time do not match, c lick Set Datalogger Clock to set thedata logger clock to the computer clock.l Optionally, specify a positive or negative Time Zone Offset to apply when setting the data logger clock. This offset allows you to set the clock for a data logger that is in adifferent time zone than the computer (or to accommodate for changes in daylightsaving time).5. Click Next.6. The data logger ships with a default GettingStarted program. If the data logger does nothave a program, you can choose to send one by clicking Select and Send Program. C lick Next.7. LoggerNet only - Use the following instructions or watch the Scheduled/Automatic DataCollection video :l The Datalogger Table Output Files window displays the data tables available to be collected from the data logger and the output file name. By default, all data tables setup in the data logger program will be included for collection. M ake note of theOutput File Name and location. Click Next.l Check Scheduled Collection Enabled to have LoggerNet automatically collect data from the data logger on the Collection Interval entered. When the Base Date andTime are in the past, scheduled collection will begin immediately after finishing theEZSetup wizard. Do not set up a scheduled collection during this tutorial. Click Next.8. Click Finish, or you may click Next to test communications, set the data logger clock, andsend a program to the data logger.4. Making the software connectionOnce you have configured your hardware connection (see USB communications (p. 2)), your data logger and computer can communicate. Use the Connect screen to send a program, set the clock, view real-time data, and manually collect data.LoggerNet users, select the Main category and Connect on the LoggerNet toolbar, then selectthe data logger from the Stations list, then click Connect. Once connected, select a table to view in the Table Monitor.PC400 users, click Connect, then Monitor Data. When this tab is first opened for a data logger, values from the Public table are displayed. To view data from other tables, click Add , select a table or field from the list, then drag it into a cell on the Monitor Data tab.For more information, see Working with data (p. 14).See Collecting data (p. 15) for more information on copying stored data from the data logger to the computer.To disconnect, click Disconnect.For more information, s ee the Connect Window Tutorial .5. Creating a Short Cut data logger programYou must provide a program for the data logger in order for it to make measurements, store data, or control external devices. There are several ways to write a program. The simplest is to use the program generator called Short Cut. For more complex programming, CRBasic Editor is used. The program file may use the extension .CR1X, .CRB, or .DLD.Data logger programs are executed on a precise schedule termed the scan interval, based on the data logger internal clock.Measurements are first stored in temporary memory called variables in the Public table. Data stored in variables is usually overwritten each scan. Periodically, generally on a time interval, the data logger stores data in tables. The data tables are later copied to a computer using your data logger support software.Use Short Cut software to generate a program for your data logger. Short Cut is included with your data logger support software.This section guides you through programming a CR1000X data logger to measure the voltage of the data logger power supply, the internal temperature of the data logger, and a thermocouple. With minor changes, these steps can apply to other measurements. U se the following instructions or watch the Quickstart part 3 video :1. Using data logger support software, launch Short Cut.l LoggerNet users, click Program then Short Cut.l PC400 users, click Short Cut.2. Click Create New Program.3. Select CR1000X Series and click Next.4. Lists of Available Sensors and Devices and Selected Measurements Available for Output aredisplayed. Battery voltage BattV and internal temperature PTemp_C are selected bydefault. During operation, battery and temperature should be recorded at least daily to assist in monitoring system status.5. Use the Search feature or expand folders to locate your sensor or device. Double-click on asensor or measurement in the Available Sensors and Devices list to configure the device (if needed) and add it to the Selected list. For the example program, expand the Sensors and Temperature folders and double-click Type T Thermocouple.6. If the sensor or device requires configuration, a window displays with configurationoptions. Click Help at the bottom of the window to learn more about any field or option.For the example program, accept the default options:l 1 Type T TC sensorl Temp_C as the Temperature label, and set the units to Deg Cl PTemp_C as the Reference Temperature Measurement7. Click the Wiring tab at the top of the page to see how to wire the sensor to the data logger.With the power disconnected from the data logger, insert the wires as directed in thediagram. Ensure you clamp the terminal on the wire, not the colored insulation. Use the included flat-blade screwdriver to open and close the terminals.8. Click OK.9. Click Next.10. Use the Output Setup options to specify how often to make measurements and how oftenoutputs are to be stored. Type 1 in the How often should the data logger measure itssensor(s)? box. Leave the units as Seconds.11. Multiple output intervals can be specified, one for each output table (Table1 and Table2tabs). For the example program, only one table is needed. Click the Table2 tab and click Delete Table.12. In the Table Name box, type a name for the table. For example: OneMin.13. Select a Data Output Storage Interval. For example: 1 minute.14. Click Next.15. Select a measurement from the Selected Measurements Available for Output list, then clickan output processing option to add the measurement to the Selected Measurements for Output list. For the example program, select BattV and click the Minimum button to add it to the Selected Measurements for Output list. Do not store the exact time that theminimum occurred. Repeat this procedure for an Average PTemp_C and Average Temp_C.16. Click Finish and give the program a meaningful name such as a site identifier. Click Save.17. If LoggerNet or other data logger support software is running on your computer, and thedata logger is connected to the computer, you can choose to send the program. Generally it is best to collect data first; so, we recommend sending the program using the instructions in Sending a program to the data logger (p. 12). Click No, do not send the program to the data logger.18. Make note of the newly generated program location and filename. By default, programscreated with Short Cut are stored in C:\Campbellsci\SCWin\.19. Close Short Cut.If your data acquisition requirements are simple, you can probably create and maintain a data logger program exclusively with Short Cut. If your data acquisition needs are more complex, the files that Short Cut creates are a great source for programming code to start a new program or add to an existing custom program using CRBasic. See the CRBasic Editor help for detailed information on program structure, syntax, and each instruction available to the data loggerhttps:///crbasic/cr1000x/ .6. Sending a program to the data loggerSome methods of sending a program give the option to retain data when possible. Regardless of the program upload tool used, data will be erased when a new program is sent if any change occurs to one or more data table structures in the following list:l Data table name(s)l Data output interval or offset l Number of fields per record l Number of bytes per fieldl Field type, size, name, or position l Number of records in tableU se the following instructions or watch the Quickstart part 4 video .1. Connect the data logger to your computer.lLoggerNet users, select Main and Connect on the LoggerNettoolbar, select the data logger from the Stations list, then Connect.l PC400 users, select the data logger from the list and click Connect .2. LoggerNet users, click Send New... (located in the Current Program section on the right sideof the window).PC400 users, click S end Program... (located in the Datalogger Program section on the right side of the window).3. PC400 users, confirm that you would like to proceed and erase all data tables saved on thedata logger. Click Yes.4. Navigate to the program, select it, and click Open. For example: navigate toC:\Campbellsci\SCWin and select MyTemperature.CR1X. Click Open.5. LoggerNet users, confirm that you would like to proceed and erase all data tables saved onthe data logger. Click Yes.6. The program is sent and compiled.7. Review the Compile Results window for errors, messages and warnings.8. LoggerNet users, click Details, select the Table Fill Times tab.PC400 user click OK then click Station Status, select the Table Fill Times tab.Ensure that the times shown are expected for your application. Click OK.After sending a program, it is a good idea to monitor the Public table to make sure sensors are taking good measurements. See Working with data (p. 14) for more information.7. Working with data7.1 Default data tablesBy default, the data logger includes three tables: Public, Status, and DataTableInfo. Each of these tables only contains the most recent measurements and information.l The Public table is configured by the data logger program, and updated at the scan interval set within the data logger program. It shows measurement and calculation results as they are made.l The Status table includes information about the health of the data logger and is updated only when viewed.l The DataTableInfo table reports statistics related to data tables. It also only updates when viewed.l User-defined data tables update at the schedule set within the program.For information on collecting your data, see Collecting data (p. 15).Use these instructions or follow the Connect Window tutorial to monitor real-time data.LoggerNet users, select the Main category and Connect on the LoggerNet toolbar, then selectthe data logger from the Stations list, then click Connect. Once connected, select a table to view in the Table Monitor.PC400 users, click Connect, then Monitor Data. When this tab is first opened for a data logger, values from the Public table are displayed. To view data from other tables, click Add , select a table or field from the list, then drag it into a cell on the Monitor Data tab.7.2 Collecting dataThe data logger writes to data tables b ased on intervals and conditions set in the CRBasic program. After the program has been running for enough time to generate data records, data may be collected by using data logger support software. During data collection, data is copied to the computer and still remains on the data logger. Collections may be done manually, or automatically through scheduled collections set in LoggerNet Setup. Use these instruction or follow the Collect Data Tutorial .7.2.1 Collecting data using LoggerNet1. From the LoggerNet toolbar, click Main and Connect, select the data logger from theStations list, then Connect.2. Click Collect Now.3. After the data is collected, the Data Collection Results window displays the tables collectedand where they are stored on the computer.4. Select a data file, then View File to view the data. See Viewing historic data (p. 16)7.2.2 Collecting data using PC4001. Click Connect on the main PC400 window.2. Go to the Collect Data tab.3. By default, all output tables set up in the data logger program are selected for collection.Typically, the default tables (DataTableInfo, Public, and Status) are not collected.4. Select an option for What to Collect. Either option creates a new file if one does not alreadyexist.l New data from data logger (Append to data files): This is the default, and most often used option. Collect only the data, in the selected tables, stored since the last datacollection from this instance of PC400 and append this data to the end of the existingfiles on the computer.l All data from data logger (Overwrite data files): Collects all of the data in the selected tables and overwrites (or replaces) the existing data files on the computer.5. Click Start Data Collection.6. After the data is collected, the Data Collection Results window displays the tables collectedand where they are stored on the computer.7. Select a data file, then View File to view the data. See Viewing historic data (p. 16)7.3 Viewing historic dataView Pro contains tools for reviewing data in tabular form as well as several graphical layouts for visualization. Use these instructions or follow the View Data Tutorial .Once the data logger has had enough time to store multiple records collect and review the data.1. To view the most recent data, connect the data logger to your computer and collect yourdata (see Collecting data (p. 15) for more information).2. Open View Pro:l LoggerNet users click Data then View Pro on the LoggerNet toolbar.l PC400 users click View Data Files via View Pro.3. Click Open, navigate to the directory where you saved your tables (the default directoryis C:\Campbellsci\[your data logger software application]). For example: navigate to theC:\Campbellsci\LoggerNet folder and select OneMin.dat.4. Click Open.AustraliaLocation: Phone: Email: Website:Garbutt, QLD Australia 61.7.4401.7700********************.au .auBrazilLocation: Phone: Email: Website:São Paulo, SP Brazil11.3732.3399**********************.br .brCanadaLocation: Phone: Email: Website:Edmonton, AB Canada 780.454.2505************************** www.campbellsci.caChinaLocation: Phone: Email: Website:Beijing, P. R. China86.10.6561.0080********************.cn Costa RicaLocation: Phone:San Pedro, Costa Rica506.2280.1564FranceLocation:Phone:Email:Website:Montrouge, France0033.0.1.56.45.15.20*******************www.campbellsci.frGermanyLocation:Phone:Email:Website:Bremen, Germany49.0.421.460974.0*******************www.campbellsci.deIndiaLocation:Phone:Email:Website:New Delhi, DL India91.11.46500481.482*******************www.campbellsci.inSouth AfricaLocation:Phone:Email:Website:Stellenbosch, South Africa27.21.8809960********************.zawww.campbellsci.co.zaSpainLocation:Phone:Barcelona, Spain34.93.2323938ThailandLocation:Phone:Email:Website:Bangkok, Thailand66.2.719.3399*********************UKLocation:Phone:Email:Website:Shepshed, Loughborough, UK44.0.1509.601141********************.ukUSALocation:Phone:Email:Website:Logan, UT USA435.227.9120********************Campbell Scientific Regional Offices。

日光温室遮阳与喷雾降温对越夏快菜生长及品质的影响

日光温室遮阳与喷雾降温对越夏快菜生长及品质的影响

日光温室遮阳与喷雾降温对越夏快菜生长及品质的影响袁丁;秦占军;武占会;梁浩;李炎艳;王宝驹;王丽萍【摘要】以京研快菜为试材,设置遮阳网、遮阳网+外侧喷雾、遮阳网+内侧喷雾3种降温处理,研究不同降温方式对日光温室环境指标的影响,以及对越夏快菜生长及品质的影响.结果表明:在夏季晴朗天气,3种降温方式均能降低日光温室室内温度,其中遮阳网+内侧喷雾处理的降温效果最好;3种降温处理均能提高快菜植株的净光合速率和气孔导度,遮阳网+内侧喷雾处理的快菜株高和叶片数显著高于仅遮阳网处理及对照,增设喷雾处理的快菜单株质量显著高于仅遮阳网处理且品质更好.【期刊名称】《中国蔬菜》【年(卷),期】2019(000)007【总页数】5页(P62-66)【关键词】日光温室;遮阳;喷雾降温;越夏生产;快菜【作者】袁丁;秦占军;武占会;梁浩;李炎艳;王宝驹;王丽萍【作者单位】河北工程大学园林与生态工程学院,河北邯郸 056038;北京市农林科学院蔬菜研究中心,北京100097;北京市农林科学院蔬菜研究中心,北京100097;农业农村部华北都市农业重点实验室,北京 100097;北京市农林科学院蔬菜研究中心,北京100097;农业农村部华北都市农业重点实验室,北京 100097;河北工程大学园林与生态工程学院,河北邯郸 056038;邯郸市农业科学院,河北邯郸 056001;北京市农林科学院蔬菜研究中心,北京100097;农业农村部华北都市农业重点实验室,北京100097;河北工程大学园林与生态工程学院,河北邯郸 056038【正文语种】中文日光温室能够为蔬菜作物提供良好的生长环境,具有显著的经济效益和社会效益,但是在北京夏季中午时段,天气晴朗、阳光较好时室外温度可达40 ℃,室内温度则高达50 ℃(崔建云等,2006)。

而蔬菜作物生长的适宜温度多为20~30 ℃,温度过高会导致坐果率低下、花瓣凋零等问题,因此研究日光温室夏季降温措施、延长温室生产时间、提高温室利用率已成为热点(刘建荣等,2018)。

敦煌西千佛洞气象环境变化特征分析

敦煌西千佛洞气象环境变化特征分析

考古与文博研究西千佛洞位于甘肃省敦煌市西南约35公里处党河北岸的崖壁上,洞窟分布在东西长2.5公里的崖壁上,现存北魏、西魏、北周、隋、唐、五代、宋、回鹘、西夏、元代洞窟22个[1]。

1961年,西千佛洞被国务院列为第一批全国重点文物保护单位。

西千佛洞始凿于北魏,经历了1500多年自然和人为因素影响,岩体存在风化、裂隙、冲沟等问题,壁画存在起甲、脱落、酥碱、变色等多种病害。

李最雄[2]、张博[3]等研究表明,石窟岩体风化受多重因素共同作用,包括岩体自身特性和自然环境,降雨、光照、温湿度变化会引起岩体矿物质吸水膨胀、失水收缩,胶结物质老化,周期性的干湿交替使得岩体结构受损,强度降低,最终导致岩体风化。

季节性的冻融循环作用,使得岩体也出现开裂、脱落现象。

西千佛洞属典型的温带大陆性干旱气候,日照强,降水少,蒸发量大,突发性强降雨会产生地表径流,冲蚀崖壁形成冲沟,威胁洞窟文物保存[4]。

敦煌地区风沙活动研究表明,偏西风形成的强风沙流造成敦煌西千佛洞气象环境变化特征分析牟锐王小伟薛平李荣华(敦煌研究院国家古代壁画与土遗址保护工程技术研究中心,甘肃敦煌736200)[摘要]为明确西千佛洞文物的赋存环境,本研究选取了2019-2020年气象站监测数据集,分析西千佛洞各气象要素如太阳辐射、气温、相对湿度、降水、风向、风速的年、季、月、日变化特征及相互关系。

研究表明:西千佛洞太阳辐射、气温、风向、风速年际较差小,降水、相对湿度年际变化较大。

各气象要素的季、月、日波动幅度较大。

太阳辐射与气温变化趋势一致,夏季最高,冬季最低,太阳辐射年均182.7W/m2,气温年均11.9℃,温差最大54℃。

年降水低于100mm,集中在6、7月,以小雨为主。

相对湿度四季呈递增趋势,RH≥67%占比20%,相对湿度最大100%,湿差最大98%。

文物处在干湿交替、冷热大幅度变化的环境中,易引发塑像壁画粉化、起甲等病害。

区域主风向为西南风,风速小对石窟影响较小;强风集中在东北~东南(NNE~SE)方向,最大风速17.9m/s,东南方向强风对崖面产生强烈风蚀作用,东北方向强风形成的风沙流对石窟文物本体及环境危害最大。

LoggerNet 软件使用精华摘录

LoggerNet 软件使用精华摘录

一、基本知识1、注意:不同的转接线在接不同的USB 口时,转化出来的COM 口不同,请及时查看。

2、波特率为9600—115200,数值越大,通信速度越快,建议使用9600 比较稳定,直连的情况下可以使用115200.3、Campbell 公司的采集器是一种可编程的数据采集器****警告1、发送程序将导致数采内部存储的数据全部被清空,并且不可修复,请在发送程序前备份数采内部数据。

如果数采配置有CFM100 或者NL115 模块,配置有CF 卡的话,卡内的数据也一起清空,请在发送程序前取卡。

2、请发送数采对应的程序,CR1000 为.cr1 后缀的文件,如果发送错误,比如为.cr3 文件,将会导致数采的不可逆损坏,只能返厂修理、4、使用Custom…(自定义采集)可以更改数据的名称以及存储路径。

在第三个选项File Format 中,可以选择ASCII Table Data,Long Header,(TOACI1)(ASCII 长字头文件,TOACI1 格式),ASCII Table Data,Long Header,(TOA5)(ASCII 长字头文件,TOA5 格式),Binary Table Data (TOB1)(二进制数据文件TOB1 格式),Array Compatible CSV(EXcell 表格文件)。

5、单击Station Status 按钮来查看数采状态二、故障诊断1、从数采采集的数据为.dat 格式,可以使用Excel 表格打开,但是很多客户在打开数据时发现数据没有分列,可以通过如下操作解决:选择某列数据,点击Excel 的数据,选择分列选项,在弹出对话框中选择,逗号分隔即可解决问题。

2、点击LoggerNet 软件主界面上的按钮CardConvert,可以转化数据。

***注意:数采内部存储的数据格式为TOB3,可以使用Cardconvert 工具将数据格式转化为TOB1,以便于Edire 软件(国际通用的处理涡动数据软件)使用,只需在数据输出的File Format 处更改为TOB1 即可。

美国Campbell数据采集仪CR1000

美国Campbell数据采集仪CR1000

A rugged instrument with research-grade performance.m e a sur e m e nt & c ontr o l d atal o gg e rCAMPBELL®SCIENTIFIC, INC.W H E N M E A S U R E M E N T S M A T T E RCR1000北京华云信通科技发展有限公司The CR1000 provides precision measurement capabilities in a rugged, battery-operated package. It consists of a measurement and control module and a wiring panel. Standard operating range is -25° to +50°C; an optional extended range of -55° to +85°C is available.*Originally, the standard CR1000 had 2 MB of data/program storage, and an optional version, the CR1000-4M, had 4 MB of memory. In September 2007, the standard CR1000 started having 4 MB of memory, making the CR1000-4M obsolete. Dataloggers that have a module with a serial num-ber greater than or equal to 11832 will have a 4 MB memory. Th e 4 MB dataloggers will also have a sticker on the canister stating “4M Memory”.CR1000Measurement and Control SystemInput/Output Terminals —Individually configured for ratiometric resistive bridge, thermocouple, switch closure, high fre-quency pulse, low-level ac, serial sensors, and more.CS I/O Port —connects with AC-powered PCs and com-munication peripherals such as phone, RF, short-haul, and multidrop modems.RS-232—provides a 9-pin DCE port for connecting a battery-powered laptop, serialsensors or RS-232 modems.Removable Power Terminal —simplifi es connection to external power supply.Peripheral Port —allows data to be stored on a CompactFlash card and/or supports Ethernet communications.{Features4 Mbyte memory*• Program execution rate of up to 100 Hz • CS I/O and RS-232 serial ports • 13-bit analog to digital conversions• 16-bit H8S Renesas Microcontroller with 32-bit • internal CPU architectureTemperature compensated real-time clock• Background system calibration for accurate mea-• surements over time and temperature changes Single DAC used for excitation and measurements • to give ratio metric measurementsGas Discharge Tube (GDT) protected inputs• Data values stored in tables with a time stamp and • record numberBattery-backed SRAM memory and clock ensuring • data, programs, and accurate time are maintained while the CR1000 is disconnected from its main power sourceSerial communications with serial sensors and • devices supported via I/O port pairs P • akBus ®, Modbus, DNP3, TCP/IP , FTP , and SMTP protocols supportedMeasurement and Control ModuleTh e module measures sensors, drives direct communi-cations and telecommunications, reduces data, con-trols external devices, and stores data and programs in on-board, non-volatile storage. Th e electronics are RF shielded and glitch protected by the sealed, stainless steel canister. A battery-backed clock assures accurate timekeeping. Th e module can simultaneously provide measurement and communication functions. Th e on-board, BASIC-like programming language sup-ports data processing and analysis routines.Wiring PanelTh e CR1000WP is a black, anodized aluminum wiring panel that is compatible with all CR1000 modules. Th e wiring panel includes switchable 12 V , redistributed analog grounds (dispersed among analog channels rather than grouped), unpluggable terminal block for 12 V connections, gas-tube spark gaps, and 12 V sup-ply on pin 8 to power our COM-series phone modems and other peripherals. Th e control module easily dis-connects from the wiring panel allowing fi eld replace-ment without rewiring the sensors. A description of the wiring panel’s input/output channels follows.Analog InputsEight differential (16 single-ended) channels mea-sure voltage levels. Resolution on the most sensitive range is 0.67 µV.Pulse CountersTwo pulse channels can count pulses from high level(5 V square wave), switch closure, or low level AC signals. Switched Voltage ExcitationsTh ree outputs provide precision excitation voltages for resistive bridge measurements.Digital I/O PortsEight ports are provided for frequency measurements, digital control, and triggering. Th ree of these ports can also be used to measure SDM devices. Th e I/O ports can be paired as transmit and receive. Each pair has 0 to 5 V UART hardware that allows serial communica-tions with serial sensors and devices. An RS232-to-logic level converter may be required in some cases. CS I/O PortAC-powered PCs and many communication peripherals connect with the CR1000 via this port. Connection to an AC-powered PC requires either an SC32B or SC-USB interface. Th ese interfaces isolate the PC’s electrical system from the datalogger, thereby protecting against ground loops, normal static discharge, and noise.RS-232 PortThis non-isolated port is for connecting a battery-powered laptop, serial sensor, or RS-232 modem. Because of ground loop potential on some measure-ments (e.g., low level single-ended measurements), AC-powered PCs should use the CS I/O port instead of the RS-232 port (see above).Peripheral PortOne 40-pin port interfaces with the NL115 Ethernet Interface & CompactFlash Module, the NL120 Ether-net Interface, or the CFM100 CompactFlash® Module. Switched 12 VoltTh is terminal provides unregulated 12 V that can be switched on and off under program control. Storage CapacityTh e CR1000 has 2 MB of fl ash memory for the Operat-ing System, and 4 MB of battery-backed SRAM for CPU usage, program storage, and data storage. Data is stored in a table format. Th e storage capacity of the CR1000 can be increased by using a CompactFlash munication ProtocolsTh e CR1000 supports the PakBus, Modbus, DNP3, TCP/IP, FTP, and SMTP communication protocols. With the PakBus protocol, networks have the distrib-uted routing intelligence to continually evaluate links. Continually evaluating links optimizes delivery times and, in the case of delivery failure, allows automatic switch over to a confi gured backup route.Th e Modbus RTU protocol supports both fl oating point and long formats. Th e datalogger can act as a slave and/or master.Th e DNP3 protocol supports only long data formats. Th e dataloggers are level 2 slave compliant, with some of the operations found in a level 3 implementation.Th e TCP/IP, FTP, and SMTP protocols provide TCP/IP functionality when the CR1000 is used in conjunction with an NL115, NL120, or third party serial IP device. Refer to the CR1000 manual for more information. Power SuppliesAny 12 Vdc source can power the CR1000; a PS100 or BPALK is typically used. Th e PS100 provides a 7-Ahr sealed rechargeable battery that should be connected to a charging source (either a wall charger or solar panel). Th e BPALK consists of eight non-rechargeable D-cell alkaline batteries with a 7.5-Ahr rating at 20°C.Also available are the BP12 and BP24 battery packs, which provide nominal ratings of 12 and 24 Ahrs, respectively. Th ese batteries should be connected to a regulated charging source (e.g., a CH100 connected to a unregulated solar panel or wall charger). Enclosure/Stack BracketA CR1000 housed in a weather-resistant enclosure can collect data under extremely harsh conditions. Th e 17565 Stack Bracket allows a small peripheral to be placed under the mounting bracket, thus conserving space. With the bracket, the CR1000 can be attached in a “horizontal” orientation in an ENC10/12 enclosure (i.e., the long axis of the CR1000 spanning the short axis of the enclosure).Above is a CR1000 mounted to the stack bracket. The Velcro strap is for fastening a peripheral to the base of the bracket.Keyboard DisplayTh e CR1000KD can be used to program the CR1000, manually initiate data transfer, and display data. Th e CR1000KD displays 8 lines x 21 characters (64 x 128 pixels) and has a 16-character keyboard. Custommenus are supported allow-ing customers to set up choiceswithin the datalogger programthat can be initiated by a simple“toggle” or “pick list”.Portable Handheld DevicesAn Archer-PCon or user-supplied PDA can be used to collect and display the CR1000’s data, transfer datalog-ger programs, graph data for up to two elements, and transfer the datalogger’s data to a PC. User-supplied PDAs require either PConnect or PConnectCE soft ware. Direct LinksAC-powered PCs connect with the datalogger’s CS I/O port via an SC32B or SC-USB interface. Th ese inter-faces provide optical isolation. A battery-powered lap-top can be attached to the CR1000’s RS-232 port via an RS-232 cable—no interface required.External Data Storage DevicesA CFM100 or NL115 module can store the CR1000’s data on an industrial-grade CompactFlash (CF) card (2 GB or less). Th e PC reads the CF card using either the CF1 CompactFlash Adapter or a 17752 USB Reader/Writer. Th e CR1000 can also store data on an SC115 2-GB Flash Memory Drive. Th is light-weight device can easily be carried to the PC for data download.CD295 DataView II DisplayTh is two-line, 32-character LCD displays one real-time value, a description, and units. It is typically mounted in an enclosure lid, which allows customers to view the CR1000’s data on-site without opening the enclosure. Short Haul ModemsTh e SRM-5A RAD Short Haul Modem supports com-munications between the CR1000 and a PC via a four-wire unconditioned line (two twisted pairs). Multidrop InterfaceTh e MD485 intelligent RS-485 interface permits aPC to address and communicate with one or more dataloggers over the CABLE3CBL cable. Distancesup to 4000 feet are supported.EthernetUse of an NL120, NL115, or NL100 interface enables the CR1000 to communicate over a local network or a dedicated Internet connection via TCP/IP. Th e NL115 can also store data on a CompactFlash card.RadiosRadio frequency (RF) communications are supported via narrow-band UHF, narrow-band VHF, spread spectrum, or meteor burst radios. Line-of-sight is required for all of our RF options.Telephone NetworksTh e CR1000 can communicate with a PC using land-lines, cellular CDMA, or cellular GPRS transceivers.A voice synthesized modem enables anyone to call the CR1000 via phone and receive a verbal report of real-time site conditions.Satellite TransmittersOur NESDIS-certifi ed GOES satellite transmitter pro-vides one-way communications from a Data Collection Platform (DCP) to a receiving station. We also off er an Argos transmitter that is ideal for high-altitude and polar applications and a METEOSAT transmitter for European applications.Data Storage and Retrieval OptionsTo determine the best option for an application, consider the accessibility of the site, availability of services (e.g., cellular phone or satellite coverage), quantity of data to collect, and desired time between data-collection sessions. Some communication options can be combined—increasing the fl exibility, convenience, and reliability of the communications.One CR1000KD can becarried from station to sta-tion in a CR1000 network.This weather station at Denali National Park, Alaska, transmits datavia a GOES satellite transmitter.Channel Expansion4-Channel Low Level AC ModuleTh e LLAC4 is a small peripheral device that allows customers to increase the number of available low-level ac inputs by using control ports. Th is module is oft en used to measure up to four anemometers, and is especially useful for wind profi ling applications. Synchronous Devices for Measurement (SDMs) SDMs are addressable peripherals that expand the data-logger’s measurement and control capabilities. For example, SDMs are available to add control ports, analog outputs, pulse count channels, interval timers, or even a CANbus interface to the system. Multiple SDMs, in any combination, can be connected to one datalogger. MultiplexersMultiplexers increase the number of sensors that can be measured by a CR1000 by sequentially connecting each sensor to the datalogger. Several multiplexers can be controlled by a single CR1000.SoftwareStarter Soft wareOur easy-to-use starter soft ware is intended for fi rst time users or applications that don’t require sophisti-cated communications or datalogger program editing. SCWin Short Cut generates straight-forward CR1000 programs in four easy steps. PC200W allows custom-ers to transfer a program to, or retrieve data from a CR1000 via a direct communications link.At /downloads you can down-load starter soft ware at no charge. Our Resource CD also provides this soft ware as well as PDF versions of our brochures and manuals.Datalogger Support Soft wareOur datalogger support soft ware packages provide more capabilities than our starter soft ware. Th ese soft ware packages contains program editing, commu-nications, and display tools that can support an entire datalogger network.PC400, our mid-level soft ware, supports a variety of telemetry options, manual data collection, and data display. For programming, it includes both Short Cut and the CRBasic program editor. PC400 does not support combined communication options (e.g., phone-to-RF), PakBus® routing, or scheduled data collection.RTDAQ is an ideal solution for industrial and real-time users desiring to use reliable data collectionsoft ware over a single telecommunications medium, and who do not rely on scheduled data collection. RTDAQ’s strength lies in its ability to handle the display of high speed data.LoggerNet is Campbell Scientifi c’s full-featured datalog-ger support soft ware. It is referred to as “full-featured” because it provides a way to accomplish almost all the tasks you’ll need to complete when using a datalogger. LoggerNet supports combined communication options(e.g., phone-to-RF) and scheduled data collection.The Network Planner, included in LoggerNet 4 or higher, gener-ates device settings and confi gures the LoggerNet network mapfor PakBus networks.Both LoggerNet and RTDAQ use View Pro to display historical data in a tabular or graphical format.The CR1000 is compatible with the AM16/32B (shown above) and AM25T multiplexers.ApplicationsThe measurement precision, fl exibility, long-term reliability, and economical price of the CR1000 make it ideal for scientifi c, commercial, and industrial applications.MeteorologyTh e CR1000 is used in long-term climatological moni-toring, meteorological research, and routine weather measurement applications.Sensors the CR1000 can measure include: Agriculture and Agricultural ResearchTh e versatility of the CR1000allows measurement of agricul-tural processes and equipmentin applications such as:plant water research•canopy energy balance•machinery performance•plant pathology•crop management•decisionsfood processing/storage•frost prediction•irrigation scheduling•integrated pest•management Wind ProfilingOur data acquisition systems can monitor conditionsat wind assessment sites, at producing wind farms,and along transmission lines. Th e CR1000 makes andrecords measurements, controls electrical devices, andcan function as PLCs or RTUs. Because the datalog-ger has its own power supply (batteries, solar panels),it can continue to measure and store data and performcontrol during power outages.Typical sensors for wind assessment applications in-clude, but are not limited to:s onic anemometers•t hree-cup and propeller•anemometers (up to10 anemometers can bemeasured by using twoLLAC4 peripherals)wind vanes•temperature sensors•barometric pressure•wetness•solar radiation•For turbine performanceapplications, the CR1000monitors electrical current,voltage, wattage, stress, and torque.Soil MoistureTh e CR1000 is compatible with the following soilmoisture measurement technologies:Soil moisture blocks are inexpensive sensors•that estimate soil water potential.Matric water potential sensors also estimate•soil water potential but are more durable thansoil moisture blocks.Time-Domain Refl ectometry Systems (TDR)•use a refl ectometer controlled by a CR1000 toaccurately measure soil water content. Multi-plexers allow sequential measurement of a largenumber of probes by one refl ectometer, reducingcost per measurement.Self-contained water content refl ectometers are•sensors that emit and measure a TDR pulse.Tensiometers measure the soil pore pressure of•irrigated soils and calculate soil moisture.Our rugged, reliable weather station measures meteorologicalconditions at St. Mary’s Lake, Glacier National Park, MT.cup, propeller, and•sonic anemometerstipping bucket•rain gageswind vanes•pyranometers•ultrasonic ranging•sensorthermistors, RTDs,•and thermocouplesbarometric pressure•sensorsRH sensors•cooled mirror•hygrometersThis vitaculture site inAustralia integrates meteo-rological, soil, and cropmeasurements.A Campbell Scientific systemmonitors an offshore windfarm in North Wales.Photo courtesy npower renewablesCopyright © 2004, 2010Campbell Scienti fi c, Inc. Campbell Scientific, Inc. | 815 W 1800 N | Logan, Utah 84321-1784 | (435) 753-2342 | 。

红狮自动化系列操作员界面面板CR1000和CR3000说明书

红狮自动化系列操作员界面面板CR1000和CR3000说明书

CR1000 and CR3000 HMIsRed Lion Automation SeriesPRODUCT HIGHLIGHTS>NEMA 4X, IP66 Front Panel Rating >Industrial Environmental Specifications •Wide operating temperature•High shock and vibration tolerance •CE, UL/cUL, UL/cUL Hazardous >Supports over 300 Industrial Drivers >SD Card for database upload/download >Built-In Web Server for Remote Access* >Real-Time Data Logging*CR1000 and CR3000 HMIs provide industry-leading protocol conversion and connectivity choices along w ith enhanced visual display features to deliver operator interface devices that easily scale and adapt as requirements change.The CR1000 and CR3000 automation HMIs from Red Lion combine an ever-expanding list of over 300 industrial drivers with the intuitive and powerful Crimson 3.1 development platform to create an operator experience designed to easily adapt as needs change and operations grow. Basic requirements for machine interface and protocol conversion are easily handled by the CR1000 products, while the CR3000 HMIs address more advanced needs with real-time data logging and a built-in web server.INDUSTRY APPLICATIONS >Factory Automation >OEM Machine Builders >Automotive >Food & Beverage >Water/WastewaterCUSU LFEATURES & BENEFITS > F ull-color HMI touchscreen•A variety of 4.3” to 15” models with widescreen(model dependent) ensures the right fit for virtually any application •16M colors>Industry-leading protocol conversion • C ommunicate with over 300 protocols• E asily convert between serial, USB and Ethernet devices•Convert up to 6 protocols simultaneously with CR1000 and up to 15 with CR3000•Manage multi-vendor environments with ease>Powerful Integration Capabilities• C rimson 3.1 software enables point-and-click configuration• U pdated 3D symbols and primitives create a modern operator experience •Ethernet, USB and serial ports make communication simple• R obust web server* provides remote access and control to reduce costly site visits•Send email and/or SMS notifications on alarm conditions*•Built-in data logging enhances troubleshooting and helps meet regulatory requirements•Automate population of data values using SQL Queries feature**Model dependentCOMMUNICATION PROPERTIESUSB PortsUSB Device:CR1000 and CR3000 (All Models) - (1) USB DeviceT ype B adheres to USB specification 1.1USB Host:CR3000 (4.3”) – (1) USB Host portCR3000 (7”, 10.4”, 15”) – (2) USB Host portsType A adheres to USB specification 2.0 and supports full-speeddata transfers with hardware overcurrent protected (0.5 A max perport)Serial Ports for programming or communications: Format/Baud ratesindependently configurableCR1000 (All) - One (1) RS232 and One (1) RS232/RS422/RS485selectableCR3000 (4.3”) - Two (2) RS232 and One (1) RS422/RS485CR3000 (7”, 10.4”, 15”) - Two (2) RS232 and Two (2) RS422/RS485 Ethernet Ports: 1500 Vrms network isolationCR1000 (All) - One (1) 10/100 BASE-T(X) port (RJ45)CR3000 (4.3”) - One (1) 10/100 BASE-T(X) port (RJ45)CR3000 (7”, 10.4”, 15”) - Two (2) 10/100 BASE-T(X) ports (RJ45) POWER INPUTCR1000 (All models) 24 VDC +/- 20%CR3000 (All models) 10 to 30 VDCMust use a Class 2 circuit according to National Electrical Code (NEC),NFPA-70 or Canadian Electrical Code (CEC), Part I, C22.1 or a Limited Power Supply (LPS) according to IEC 60950-1 or Limited-energy circuit according to IEC 61010-1. Power connection via removable threeposition terminal block.Battery: Lithium coin cellTypical lifetime of 5 yearsPOWER CONNECTIONHigh compression cage-clamp terminal blockWire Strip Length: 0.3” (7.5 mm)Wire Gauge Capacity: 12 to 24 AWG (3.31 to 0.20 mm2) copper wire Torque: 4.4-5.3 inch-lbs (0.5-0.6 N-m)NETWORK MEDIA10BaseT: ≥ Cat3 cable100BaseTX: ≥ Cat5 cableENVIRONMENTALOperating Temperature: -10°C to 50°CStorage Temperature: -20°C to 70°COperating Humidity: 0 to 85% (non condensing)Operating Altitude: Up to 2000 metersShock: 30 g per IEC 68-2-27Vibration: 2 g @ 5-500 Hz per IEC 68-2-6CERTIFICATION & COMPLIANCECE ApprovedImmunity: IEC/EN 61000-6-2 for Industrial LocationsEmissions: IEC/EN 6100-6-4 for Industrial Locations; CISPR 11 Class A Safety: IEC/EN 61010-1RoHS CompliantUL ListedClass I, Division 2, Groups A, B, C and D for CR3000 onlyType 4X Indoor / IP66 Enclosure rating (front face only) MECHANICALConstruction: Polycarbonate enclosure with NEMA 4X/IP66 rating forindoor use when correctly fitted with the gasket provided. Installation Category II, Pollution Degree 2.Weight:CR1000 4.3” model – 15.0 oz (425 g)CR1000 7” model – 1.91 lb (868 g)CR1000 10.4” model – 3.08 lb (1.395 Kg)CR3000 4.3” model – 1.00 lb (454 g)CR3000 7” model – 2.01 lb (913 g)CR3000 10.4” model – 3.16 lb (1.435 Kg)CR3000 15” model – 4.12 lb (2.155 Kg)Specifications are subject to change. Visit for more information.Dashes in listed model numbers added to improve readability, and are not included in orderable part numbers. CR1000 and CR3000 HMIs Ordering Guide4.3” models7” Models10” ModelsTHIS VIEW SHOWN WITH MOUNTING PLATE AND BRACKETSTHIS VIEW SHOWN WITH MOUNTING PLATE AND BRACKETSConnect. Monitor. Control.ADLD0478 042718 © 2018 Red Lion Controls, Inc. All rights reserved. Red Lion, the Red Lion logo, N-Tron and Sixnet are registered trademarks of Red Lion Controls, Inc. All other company and product names are trademarks of their respective owners.As the global experts in communication, monitoring and control for industrial automation and networking, Red Lion has been delivering innovative solutions for over forty years. Our automation, Ethernet and cellular M2M technology enables companies worldwide to gain real-time data visibility that drives productivity. Product brands include Red Lion, N-Tron and Sixnet. With headquarters in York, Pennsylvania, the company has offices across the Americas, Asia-Pacific and Europe. Red Lion is part of Spectris plc, the productivity-enhancing instrumentation and controls company. For more information, please visit .THIS VIEW SHOWN WITH MOUNTING PLATE AND BRACKETSTHIS VIEW SHOWN WITH MOUNTING PLATE AND BRACKETS4.3” models7” Models10” Models。

LoggerNet操作说明_CR1000

LoggerNet操作说明_CR1000

一、概述自动气象站采用的LoggerNet软件是Campbell 公司开发的一种集通讯和数据采集于一体的应用软件,运行在Windows95,98,Windows NT 4.0、Windows 2000或Windows XP环境下的应用软件。

用户可通过该软件进行配置,建立PC机和数据采集器的连接,发送采集程序,收集数据,观察实时数据,以及进行数据分析等。

LoggerNet的最新版本为3.1.5。

安装软件时。

建议LoggerNet的运行路径和工作路径安装在不同的磁盘分区上,工作路径最好不要安装在计算机的操作系统所在的磁盘上,因为LoggerNet默认的收集数据的路径在其工作路径所在的磁盘上。

当然,下载数据时,用户可以选择不同的路径存放文件。

打开LoggerNet软件,将会弹出一个工具条式的主界面,如下图一所示。

主界面上我们采集数据主要用到“Setup”、“Connect”、“View”按钮。

二、通讯设置(“Setup”窗口)单击主界面上的“Setup”按钮,将弹出“Setup”窗口,如图所示。

设置Setup窗口的步骤如下:2.1.1点击“AddRoot”按钮,弹出Add窗口2.1.2选择添加“ComPort”,弹出此时选择PakBusPort(Other Logger)选项弹出选择CR1000选项然后点击Close按钮,Setup窗口变为点击Setup窗口下面的Apply按钮,再在窗口左侧的导航栏里选择CR1000,单击窗口右面的“Data Files”标签页,出现如图所示的画面。

将CR1000与电脑连接好再点击标签页下面的Get Table Definitions按钮得到采集器的数据表定义。

再在标签页左边数据表栏中选择数据表(注:数据表名在编写程序里命名)此时在标签页的“Output File Name”下面的文本框显示为采集数据路径和名,其路径和名可以更改,点击文本框右面的按钮,在弹出的Windows“另存为”对话框内选择存储路径和文件名。

工程安装调试报告(超声波测风用)

工程安装调试报告(超声波测风用)

系统安装调试报告(超声波测风)项目名称:项目地址:项目实施人:项目实施日期:年月日项目简介风场址号拟安装日期年月日风场地址塔厂址名称纬度盛行风向经度地形类型海拔高度塔高项目实施人签字:签字时间:系统简介系统名称:系统主要施工内容:项目开工日期:年月日项目拟完成日期:年月日系统设备清单及配件清点记录序号设备名称合同数量实际到货数量零配件全否备注1风塔2 普通测风系统3 工控机KVM4 超声测风系统5 规约转换6 无线传输模块7 服务器8 pc机9 防火墙10 反向隔离11 机柜注:1、实际到货与合同型号或数量不符,请在备注中说明原因;2、设备随机清单、合格证、保修卡、安装手册等如不齐全,请在备注中说明缺少什么3、设备随机零配件不全请在表中说明项目开工组织以下事项是否齐备,请做选择,如不满足,请在备注中说明:☐项目管理实施规划(施工组织设计)已审批;☐施工图会检已进行;☐各项施工管理制度和相应的作业指导书已制定并审查合格;☐安全文明施工二次策划满足要求;☐施工技术交底已进行;☐施工人力和机械已进场,施工组织已落实到位;☐物资、材料准备能满足连续施工的需要;☐计量器具、仪表经法定单位检验合格;☐特殊工种作业人员能满足施工需要。

备注:如全部满足,请签字确认,并进行项目施工项目实施人签字:签字日期:年月日第一部分:测风塔的安装(本项目如果不包含测风塔,本部分可以不填写)测风塔塔架出厂资料测风塔制造商:产品出厂合格证标示工程名称:基站名称:产品名称:测风通讯塔规格型号:M数量:一座出厂编号:本产品符合标准:GB/T2694-2003《输电线路铁塔制造技术条件》DL/T646-1998《钢管杆塔制造技术条件》YDT/757-1995《微波通信铁塔制造技术条件》GY65-1989《广播电视塔制造技术条件》GB50205-2001《钢结构工程施工及验收》铁塔出厂检验记录工程名称规格型号M样品基数1基产品标准YD/T5132-2005 检验标准YD/T5132-2005 报告编号材质配件目次检验项目名称标准要求允许偏差实测结果实测偏差结论一材料符合标准和实际要求二装配1 端距±5.02 通信孔距与构件中心相对偏差±1.03连接间隙变宽50MM以下≤1.04 变宽50MM以上≤2.05 接头装配尺寸位移有孔≤1.06 无孔≤5.0三试装1 试装就位率≥99%2 通心孔率≥96%3 试装控制尺寸正常结论按YD/T5132-2005标准试装并检验所有项目符合设计要求,检验合格。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

数字I/O通道
• 作为数字输入输出通道
输入特性 • H 3.8 to 5.3 VDC • L < -0.3 to 1.2 VDC 输出特性 • H(on) = 5V +/- 0.1V • L (off) = <0.1V • 最大通道电流= 1mA
数字I/O通道
用于SMD 通讯 字符串传 输 Pakbus协议传 输 文件传输 标准RS232协 议传输
• 冷端温度(Tref) 在Crbasic中,可以用PanelTemp( PTemp, Integ)指令来调用数据采 集器接线面板温度。我们用Ptemp来做冷端温度补偿。
周期/频率信号测量
3 2 1 0
a 列1
列2
周期/频率信号测量
3
2 1 0 0 3 6 9 12 15 18 a 阈值,一般 设为峰值的 1/2 0:输出周期 1:输出频率
TCType Tref
• 热电效应(塞贝克效应) 热电偶回路中产生的电势差为:
NA E AB (T , T0 ) (T T0 ) ln e NB


T
T0
A
B d T
上式中前一项是由于两种不同材料金属连接时产生的接触电势 差,取决于材料的电子密度;而后一项是因同一种材料的均质导 体两端温度不同时产生的温差电势,即所谓汤姆逊效应。但由于 导体汤姆逊效应引起的电势差甚小,常可忽略。于是当材料 A、B 的特性(NA、NB)为已知时,并使一端温度T0固定,则待测温度 T 是电动势EAB(T,T0)的单值函数。这给工程中用热电偶测量温度 带来极大的方便。
BrHalf( Dest, Reps, Range, SEChan, ExChan, MeasPEx, ExmV, RevE x, SettlingTime, Integ, Mult, Offset )
whether the excitation should be reversed
这个选项的目的是 消除系统误差。 系统误差是由一些固有的因素(如测量方法的缺 陷)产生的, 理论上总是可以通过一定的手段来消除。如天平的两臂应是等长的, 可实际上是不可能完全相等的;天平配置的相同质量的砝码应是一样的,可实际上 它们不可能达到一样。电子学中,导线和测量仪器的接触电阻,传感器输出线不等 长,所有这些都是系统误差的来源。 消除系统误差的一个普遍方法叫换位测量(反向激发)。 Eg: 1 or 0
0 0.4 0.8 2 1.6 2 2.4 2.8
电压(mv)
800 700 600 500 400 300 200 100 0
H端对地电压
L端对地电压
0 0.22 0.44 0.66 0.88 1.1 1.32 1.54 1.76 1.98 2.2 2.42
800 600 400
Vh-VL
H-L 200 0 0 0 0 0 0 1 1 1 1 1 2 2
数据采集器工作过程 传感器输出 模拟量 热电偶,电压,电流,周期,桥式测量电阻 脉冲量 开关,低压交流,高频信号 数字I/O: TTL,RS232,高频,脉冲,开关,sdi-12….
数据采集器 信号整合
数据检索 外部储存
模拟-数字 转换 加工 数据储存
数字 采集 直接/远程通讯
计算机
数据采集器测量过程演示
startFreq和EndFreg是 频率范围,频率范围 为20Hz~5KHz
检波刷新周期(ms)
测量前延时 时间(ms)
VibratingWire ( Dest, Reps, Range, SEChan, ExChan, StartFreq, EndFreq, TSweep, Steps, DelMea s, NumCycles, DelReps, Multiplier, Offset )
模拟通道
模拟电压 桥式输入 热电偶 周期/频率信号
模拟电压测量
单端接法
差分接法
单端通道标号
差分通道标号
无电磁干扰时传感器输入端对地电压 600 500 400 300 200 100 0 0 0.4 0.8 2 1.6 2 2.4 2.8
有电磁干扰时传感器输入端对地电压
电压(mv)
600 500 400 300 200 100 0
channel number of measrue
measure the offset voltage
模拟通道Range
CR1000 Range
Range +/- 5000 +/- 2500 +/- 250 +/- 25 +/- 7.5 +/- 2.5 Basic Resolution (uV) 1330 667 66.7 6.7 2 0.67
列1
列2
PeriodAvg(Dest, Reps, Range, SEChan, Threshold, Option, Cycles, Ti meout, Mult, Offset)
当Cycles不为1时, 两次测量间隔
要测量周期数,如果输入3 最后输出3个周期测量均值
and Range Code mV2500 mV250 mV25 mV2_5
Mult,offset 选项(偏移和倍乘)
自然信息
转换函数
电学信号
VoltDiff( Dest, Reps, Range, DiffChan, RevDiff, SettlingTime, Integ, Mult, O ffset ) 差分测量指令中的参数设置和单端测量基本相同,唯一不同的是 RevDiff这一项,这一项只有两个选择,false or ture。如果选择ture, 这条指令会额外测量一次,不过这次的测量顺序是先测量L通道,然后 测量H通道,最后将两次测量的结果取平均值。 差分测量可有效消除电磁干扰, RevDiff用于减少系统自身工作时所 出现的随机误差。
7
Settling Time Parameter
6
5 4 3 2 1 0 被测信号 电磁噪音 叠加信号
-1
-2
6000 4000 2000 0 -2000 1 4 7 1013161922252831 -4000 -6000
Integration Parameter
0 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6
检波分布次数,假设我们 要测量某未知频率为、 1kHz左右的波,我们将频 率范围设置为 100Hz~1.5KHz 如果steps设置为100,那 么在测量频率时,每 140Hz跳一次。如果输入-1, 数据采集器将进行全频率 扫描
循环测量 次数
两次测量 时间间隔 (ms)
脉冲通道 (pulse)
开关次数计数 高频频率输eps, Range, DiffChan, TCType, TRe f, RevDiff, SettlingTime, Integ, Mult, Offset )
TCSE( Dest, Reps, Range, SEChan, TCType, TRef, MeasOff, SettlingTime, Integ, Mult, Offset )
VoltSE( Dest, Reps, Range, SEChan, MeasOff, SettlingTime, Integ, Mult, Offset )
Variable to store the results
The number voltage of range for repetitions measure for the measure
低压交流信号频率/周期
脉冲通道
开关计数:开关最少时间周期 = 11mS 其中:至少5mS 打开, 至少6mS 关闭 高频测量,频率不能超过 250kHz 低压交流信号测量,见下表: RMS (mV)
20 200 2000 5000
Range (Hz)
1 to 20 0.5 to 200 0.3 to 10,000 0.3 to 20,000
TCType Tref
• • • • • • • • • • 热电偶类型(TCType): Alphanumeric Numeric Type TypeT 0 铜/ 铜镍合金 TypeE 1 镍铬合金 / 铜镍合金 TypeK 2 镍铬合金 / 镍铝合金 TypeJ 3 铁/ 铜镍合金 TypeB 4 铂铑30合金/铂铑6合金 TypeR 5 铂铑13/铂 TypeS 6 铂铑10合金/铂 TypeN 7 镍铬硅合金 / 镍硅合金
Gain 1 10 33 100
Signal (peak-topeak) Min 500 mV 10 mV 5 mV 2 mV
Signal (peak-topeak) Max 10 V 2V 2V 2V
Min Pulse-Width 2.5 us 10 us 62 us 100 us
Max Frequency 200 kHz 50 kHz 8 kHz 5 kHz
测量的关键设置,有关测量时序和测量 阶段整合信号的时间 Settling time 有两个选择,0和非0 如果选择0,就默认settling time和integ 相等。非0的选择,单位为微秒(us) Integ
Setup & Settle
Integ.
12位A/D Conv.
Reset
有三个选择:250us,_60Hz,_50Hz
脉冲通道 (pulse)
• 测量指令:
测量方式选择,一共有三种方式: 0 高频 1 低压交流 2 开关量
测量结果储存方式选择,共3种: 0 计数 1 储存频率 >1 以XXms为测量周期 对频率进行测量,xx必须为扫描间 隔的整数倍
PulseCount( Dest, Reps, PChan, PConfig, POption, Mult, Offset )