单层工业房的课程设计例题

合集下载

单层单跨工业厂房设计计算书课程设计

单层单跨工业厂房设计计算书课程设计

混凝土结构课程设计书计算书题目:单层单跨工业厂房班级:姓名:学号:教师:时间:目录第一章设计资料...................................................................................................... - 0 -第二章厂房标准构件及排架柱材料选用.............................................................. - 2 -厂房中标准构件选用情况................................................................................. - 2 -排架柱材料选用................................................................................................ - 3 -第三章排架柱高与截面计算................................................................................. - 3 -排架柱高计算.................................................................................................... - 3 -排架截面尺寸计算 ............................................................................................ - 3 -第四章排架柱上的荷载计算................................................................................. - 4 -屋盖自重计算.................................................................................................... - 4 -柱自重计算........................................................................................................ - 4 -吊车、吊车梁及轨道自重计算 ......................................................................... - 4 -屋面活荷载计算................................................................................................ - 4 -吊车荷载计算.................................................................................................... - 5 -风荷载计算........................................................................................................ - 5 -第五章内力计算.................................................................................................... - 6 -G作用内力计算 ........................................................................................... - 6 -x屋面活荷载内力计算 ........................................................................................ - 8 -吊车荷载作用内力计算 .................................................................................... - 8 -风荷载作用...................................................................................................... - 10 -最不利荷载组合.............................................................................................. - 11 -第六章柱的配筋计算 .......................................................................................... - 14 -上柱配筋计算:.............................................................................................. - 14 -下柱配筋计算:.............................................................................................. - 15 -斜截面受剪承载力验算 .................................................................................. - 17 -柱牛腿设计...................................................................................................... - 18 -柱的吊装验算.................................................................................................. - 18 -第一章设计资料一、设计题目2、材料:混凝土:C20,C25,C30。

单层单跨工业厂房课程设计

单层单跨工业厂房课程设计

单层单跨工业厂房课程设计————————————————————————————————作者:————————————————————————————————日期:《混凝土与砌体结构》课程设计计算说明书设计题目:单层单跨工业厂房课程设计2011年 06 月 15 日一 经设计确定以下做法和相应荷载的标准值:1本工程为某单层单跨工业产房,无抗震设防要求.跨度为24m,长度为66m ,柱距为6 m 。

选用二台Q=10t 的中级工作制A5桥式吊车,吊车轨顶标高为9.2 m,厂房采用钢筋混凝土装配式结构.2(1)屋面板:选自[G410㈠],板重: 1.3kN/ m 2嵌缝重:0.1kN/ m 2 (2)天沟板:选自[G410㈢](3)天沟重(包括水重):17.4kN/根(4)天窗架:Π形钢筋混凝土天窗架选自[G316].天窗架及挡风板传到屋架上的重量(5)预应力钢混筋凝土折线形屋架选自[G415㈠],屋架轴线图尺寸如图23所示。

每榀屋架重60。

5kN 。

(6)屋盖支撑:选自[G415㈠]重量为:0.05kN/ m 2 (沿水平面)(7)基础梁:选自[G320],b ×h=250×450mm, 每根自重:16。

90kN (8)吊车梁:选自[G323㈠],见图24每根自重:50kN轨道及垫层重:0.6kN/ m9)连系梁与过梁,截面与尺寸见剖面图.(10)柱间支撑:选自[G142。

1] 二 柱截面尺寸与高度的确定 基础采用单独杯形基础,基础顶面标高为﹣0.6m 柱顶标高为11。

4m ,牛腿顶面标高为7.8m 。

柱子尺寸:a )、柱子高度:上柱高m m m H U 6.38.74.11=-=下柱高m m m H L 4.86.08.7=+= 柱总高m m m H 0.126.04.11=+=11.10200400200+0.0001400224002008002-21502525150150100400240175017.80011.403004004001-1400150图 25b )、柱截面尺寸:建议上柱为方形截面,b ×h=400×400mm ,下柱为工字形截面,b ×h ×h f=400×800×150mm,牛腿尺寸、柱下端矩形截面部分高度尺寸见图25.柱截面几何特征值为:251106.1mm A ⨯= 2911013.2mm I ⨯= m kN g /0.41= 25210775.1mm A ⨯=2921038.14mm I ⨯=m kN g /44.42=三 荷载计算 1、恒载(1)屋盖恒载(防水层+隔气层)自重 2/35.0m kNmm 20厚水泥砂浆找平层 33/40.002.0/20m kN m m kN =⨯预应力混凝土屋面板(包括灌缝) 2/40.1m kN 屋盖钢支撑 2/05.0m kN 2/2.2m kN天窗架 kN 7.37天沟重(包括水重) 根/4.17kN屋架重力荷载为榀/5.60kN ,则作用于柱顶的屋盖结构重力荷载设计值:kNkN kN kN m m m kN G 98.244)4.177.372/5.602/186/2.22.121=+++⨯⨯⨯=((2)吊车梁及轨道重力荷载设计值:kN m m kN kN G 76.656/8.0502.13=⨯+⨯=)((3)柱自重重力荷载设计值:上柱kN m m kN G G B A 28.176.3/42.144=⨯⨯== 下柱kN m m kN G G B A 76.444.8/44.42.155=⨯⨯==2、屋面活荷载屋面活荷载标准值为2/5.0m kN ,学荷载标准值为2/2.0m kN ,后者大于前者,故仅按前者计算。

单层厂房课程设计例题

单层厂房课程设计例题

2.7单层厂房结构设计实例2.7.1设计任务某厂金工车间的等高排架。

该金工车间平、立面布置如图2-53所示。

柱距除端部为m 5.5,其余均为m 6,跨度m 18 m 18;每跨设有两台吊车,吊车工作制级别为5A 级,轨顶标高为2.7积图2-53(a) 厂房立面图1图2-53(b) 平面图屋面做法:绿豆砂保护层2.7.2设计参考资料1.荷载资料,见表2-15:表 2-15 荷载资料2.吊车起重量及其数据,见表2-16。

表2-16 吊车起重量及其数据3.地质资料,见表2-17。

表2-17 地质资料4.预应力屋面板、嵌板及天沟板选用,见表2-18。

表2-18 预应力屋面板、嵌板及天沟板5.屋架选用图集,见表2-19。

表2-19 屋架选用图集6. 吊车梁选用图集,见表2-20。

表2-20 吊车梁选用图集注:轨道连结件重:7.基础梁:选用标准图号320G 3-JL ,kN 7.16/根。

8.钢窗重:2kN/m 45.0。

9.常用材料自重,见表2-21。

表2-21 常用材料自重2.7.3 结构构件选型及柱截面尺寸确定因该厂房跨度在15~36m之间,且柱顶标高大于8m,故采用钢筋混凝土排架结构。

为了使屋盖例如:下柱工形截面100150900400⨯⨯⨯得 惯性矩求法如下:48232331038.195))325150450(25150213625150(4)37515030012150300(212900100mm I ⨯=--⨯⨯⨯+⨯⨯+⨯⨯+⨯⨯+⨯=本设计仅取一榀排架进行计算,计算单元和计算简图如图2-55所示。

图2-55 计算单元和计算简图2.7.4荷载计算 1. 永久荷载⑴屋盖永久荷载 2kN/m 35.0二毡三油防水层绿豆砂浆保护层400400150 400 900 1002525 150400600150 40010001002525 150A 柱B 柱20厚水泥砂浆找平层 230.40kN/m m 02.0kN/m 20=⨯ 80厚泡沫混凝土保温层 230.64kN/m m 08.0kN/m 8=⨯预应力混凝土大型屋面板(包括灌缝)2kN/m 4.1屋盖钢支撑 2kN/m 05.0 总计 2kN/m 84.2屋架重力荷载为60.5kN/榀,则作用于柱顶的屋盖结构的重力荷载标准值为:kN 61.18360.5/218/2684.21=+⨯⨯=k G(2) 吊车梁及轨道重力荷载标准值:kN 4960.82.44k 3=⨯+=G(3)柱自重重力荷载标准值 A 、C 柱:上柱:.4kN 413.60.4k 4C k 4A =⨯==G G 下柱: kN 49.306.569.4k 5C k 5A =⨯==G G B 柱:上柱:.6kN 123.60.6k 4B =⨯=G 下柱:.11kN 236.594.4k 5B =⨯=G 各项永久荷载作用位置如图2-56所示。

课程设计——混凝土厂房设计

课程设计——混凝土厂房设计

混凝土单层工业厂房设计一、设计课题单层工业厂房排架设计结构布置平面图注:本工程采用小括号()的数据二、排架柱设计1.计算简图排架跨度取厂房的跨度21m,上柱高度等于柱顶标高减取牛腿顶标高。

下柱高度从牛腿顶算至基础顶面。

为了得到排架柱的截面几何特征,需要假定柱子的截面尺寸。

从刚度条件出发。

1)确定柱子各段高度基底标高为-0.7m, 则柱总高H=12.6+0.7=13.3m, 则上柱的高度Hu=13.3-9.4=3.9m, 下柱高度HL=8.7+0.7=9.4m,计算简图如下图1-1所示图1-12)确定柱截面尺寸下柱截面高度,根据吊车起重量及基础顶面至吊车梁顶的高度h=900mm根据顶面至吊车梁底的高度, 下柱截面宽度:400mmA,B轴柱子采用同种截面,柱子几何尺寸如计算简图如下图1-2所示图1-23)计算柱截面几何特征表1-3 截面几何特征柱号A柱B柱上柱下柱上柱下柱截面尺寸(mm)正方形400×400 工字形400×900×100矩形400×400工字形400×900×100面积A(103mm2) 160.0 157.5 160.0 157.5 惯性矩I(106mm4) 2133 16611 2133 16611每米重量G(KN/m) 4.00 3.94 4.00 3.942.荷载计算排架的荷载包括恒载、屋面活荷载、吊车荷载和风荷载。

荷载均计算其标准值。

1)恒载恒载包括屋盖自重、上柱自重、下柱自重、吊车梁及轨道自重。

①屋盖荷载P1面荷载:二毡三油防水层上铺小石子: 0.35KN/ m220厚水泥砂浆找平层: 0.40KN/ m2预应力混凝土屋面板,其自重(包括细石混凝土填缝、油毛毡贴缝):1.50KN/ m2------------------------------------------------------------------------------------------------------------------------------------------------------------------------小计 2.25 KN/m2外天沟板线荷载:天沟板(已计满水及找坡): 25KN/个集中荷载:预应力混凝土折线形屋架(包含支撑, YWJ21跨度 21m): 111.8KN/榀)屋架作用在柱顶的恒载标准值:A柱:P1A=2.25×6×21/2+25+0.5×111.8=222.65KNB柱:P1B=2.25×6×21/2+25+0.5×111.8=222.65KNP1作用点位置与纵向定位轴线的距离为150mm,如图2-1所示②上柱自重P2A柱:P2A=4×3.9=15.6KNB柱:P2B=4×3.9=15.6KN下柱自重P3下柱大部分截面为I 形。

完整钢结构课程设计

完整钢结构课程设计

1.设计资料: ......................................................................................................... 错误!未定义书签。

2.结构形式与布置 ................................................................................................. 错误!未定义书签。

3.荷载计算 ............................................................................................................. 错误!未定义书签。

4.内力计算 ............................................................................................................. 错误!未定义书签。

附件:设计资料1、设计题目:单层工业厂房屋盖结构——梯形钢屋架设计2、设计任务及参数:第五组:某地一机械加工车间,长84m,跨度24m,柱距6m,车间内设有两台40/10T中级工作制桥式吊车,轨顶标高18.5m,柱顶标高27m,地震设计烈度7度;采用梯形钢屋架,封闭结合,×6m预应力钢筋混凝土大型屋面板m2,上铺100mm厚泡沫混凝土保温层容重为1KN/m3,三毡四油上铺绿豆砂防水层m2,找平层2cm厚m2,卷材屋面,屋面坡度i=1/10,屋架简支于钢筋混凝土柱上,混凝土强度等级C20,上柱截面400×400mm;钢材选用Q235B,焊条采用E43型;屋面活荷载标准值m2,积灰荷载标准值m2,3、设计任务分解学生按照下表分派的条件,完成梯形钢屋架设计的全部相关计算和验算及构造设计内容;表-34、设计成果要求在教师指导下,能根据设计任务书的要求,搜集有关资料,熟悉并应用有关规范、标准和图集,独立完成课程设计任务书指导书规定的全部内容;1需提交完整的设计计算书和梯形钢屋架施工图;2梯形钢屋架设计要求:经济合理,技术先进,施工方便;3设计计算书要求:计算依据充分、文理通顺、计算结果正确、书写工整、数字准确、图文并茂,统一用A4纸书写打印;A、按步骤设计计算,各设计计算步骤应表达清楚,写出计算表达式及必要的计算过程,对数据的选取应写明判断依据;B、计算过程中,必须配以相应的计算简图;C、对计算结果进行复核后,为保证施工质量且方便施工,应按规范要求对计算结果进行调整并写明依据;4梯形钢屋架施工图共两张,图纸绘制的要求:布图合理,版面整齐,图线清晰,标注规范,符合规范/图集要求;单层工业厂房屋盖结构——梯形钢屋架设计1.设计资料:1某地一机械加工车间,长84m,跨度24m,柱距6m,车间内设有两台40/10T 中级工作制桥式吊车,轨顶标高18.5m,柱顶标高27m,地震设计烈度7度;采用梯形钢屋架,封闭结合,×6m 预应力钢筋混凝土大型屋面板m 2,上铺100mm 厚泡沫混凝土保温层容重为1KN/m 3,三毡四油上铺绿豆砂防水层m 2,找平层2cm 厚m 2,卷材屋面,屋面坡度i=1/10,屋架简支于钢筋混凝土柱上,混凝土强度等级C20,上柱截面400×400mm;钢材选用Q235B,焊条采用E43型;屋面活荷载标准值m 2,积灰荷载标准值m 2,雪荷载及风荷载见下表;2屋架计算跨度)(7.233.0240m l =-=3跨中及端部高度:设计为无檩屋盖方案,采用平坡梯形屋架,端部高度mmh 19000=中部高度mm h 3100=为6.7/0l ,屋架跨中起拱500/l 考虑,取48m. 2.结构形式与布置屋架形式及几何尺寸如图所示:图1.梯形钢屋架形式和几何尺寸根据厂房长度102m>60m、跨度及荷载情况,设置三道上、下弦横向水平支撑;因柱网采用封闭结合,厂房两端的横向水平支撑设在第一柱间,该水平支撑的规格与中间柱间支撑的规格有所不同;在所有柱间的上弦平面设置了刚性与柔性系杆,以保证安装时上弦杆的稳定,在各柱间下弦平面的跨中及端部设置了柔性系杆,以传递山墙风荷载;在设置横向水平支撑的柱间,于屋架跨中和两端各设一道垂直支撑;梯形钢屋架支撑布置如图下图所示:屋架上弦支撑布置图屋架下弦支撑布置图3.荷载计算屋面和荷载与雪荷载不会同时出现,计算时,取较大的荷载标准值进行计算;故取屋面活荷载2m 进行计算;屋面风荷载迎风面 m KN /88.51235.00.1)0.1(4.11-=⨯⨯⨯-⨯=ω 背风面 m KN /82.31235.00.165.0(4.11-=⨯⨯⨯-⨯=ω由于屋面坡度较小,对荷载影响小,未予考虑;风荷载对屋面为吸力,重屋架不考虑;表 1 荷 载 计 算 表设计屋架时,应考虑以下三种荷载组合: .全跨永久荷载 + 全跨可变荷载全跨节点永久荷载及可变荷载:KN F 991.4865.1)82.16234.3(=⨯⨯+=.全跨永久荷载 + 半跨可变荷载全跨节点永久荷载:611.3265.16234.31=⨯⨯=F半跨节点可变荷载:KN F 38.1665.182.12=⨯⨯=.全跨屋架包括支撑自重+半跨屋面板自重+半跨屋面活荷载:全跨节点屋架自重:KN F 67.465.15184.03=⨯⨯=半跨节点屋面板自重及活荷载:KN F 31.2365.1)7.089.1(4=⨯⨯+=1、2为使用节点荷载情况,3为施工阶段荷载情况; 4.内力计算屋架在上述三种荷载组合作用下的计算简图如图所示:屋架计算简图由图解法或数解法解得F=1的屋架各杆件的内力系数F=1作用于全跨、左半跨和右半跨;然后求出各种荷载情况下的内力进行组合,计算结果见表2屋架构件内力组合表竖杆AaCb、EcGdHRIe 0 00 0 0 0 0 0 05.杆件设计1上弦杆整个上弦采用等截面,按GH,HI杆件的最大内力设计,即KNN89.797-=上弦杆计算长度:在屋架平面内,为节间轴线长度,即在屋架平面外,本屋架为无檩体系,并且认为大型屋面板只起到刚性系杆作用,根据支持布置和内力变化情况,取oyl为支撑点间的距离,即mmloy6000=根据屋架平面外上弦杆的计算长度,上弦杆截面选用两个不等肢角钢,短肢相并;如下图所示;腹杆最大内力KNN06.440-=,由屋架节点板厚度参考可知:中间节点板与垫板厚度取10mm,支座节点板刚度取12mm;设70=λ,查Q235钢的稳定系数表,可得751.0=ϕ由双角钢组成的T形和十字形截面均属于b类,则需要的截面积为236.4941215751.01089.797mmfNA=⨯⨯==ϕmmlloox1508==需要回转半径:mm l i oxx 5.21701508===λ , mm l i oy y 7.85706000===λ根据需要A,x i ,y i 查角钢规格表,选用101101802⨯⨯L ,肢背间距a=10mm,则:25680mm A =,mm i x 3.31=,mm i y 3.86=按所选角钢进行验算:52.693.866000===yoy y i l λ<λ=150, 758.0=y ϕb 类 双角钢T 型截面绕对称轴y 轴应按扭曲计算长细比yz λ,6.331160056.056.0110.1110=⨯=<==b l t b y 则yz λ=y λ=,754.0=ϕ,MPa MPa A N 3.1865680754.01089.7973=⨯⨯=ϕ<MPa 215故所选截面满足要求;填板每个节间放一块满足1l 范围内不少于两块,尺寸取60mmx130mmx10mm 则 间距cm x i cm l d 2.12513.340404.7528.150==<==,取80cm; 2下弦杆整个下弦杆采用同一截面,按最大内力所在的杆计算;K N 86.741=Nmm l ox 3000= ,mm l oy 118502/23700==因跨中有通长系杆,所需截面积为:235.34502151086.741mm f N A =⨯==选用101101802⨯⨯L ,因oy l ≥ox l ,故用不等肢角钢,短肢相并,如下图;25680mm A =,mm i x 3.31=,mm i y 3.86=8.953.313000===x ox x i l λ<350,31.1373.8611850===y oy y i l λ<35018.483.311508===x ox x i l λMPa MPa A N 21561.13056801086.7413<=⨯==σ故所选截面满足要求;填板每个节间放一块,尺寸取60mm ×130mm ×10mm,则 间距cm i cm l d 4.25013.380801502300=⨯=<==,取150cm; 3斜腹杆 ①端斜杆aB :杆件轴力 KN N 06.440-= 计算长度 =ox l mm l oy 2448=因=ox l oy l ,故采用不等肢角钢,长肢相并,使≈x i y i ;选用8801252⨯⨯L ,肢背间距a=10mm,则: 23200mm A =,mm i x 1.40=,mm i y 7.32= 按所选角钢进行验算:86.747.322448===yoy y i l λ<λ=150 双角钢T 型截面绕对称轴y 轴应按扭曲计算长细比yz λ,7.1788.24458.058.0108.08202=⨯=<==b l t b y 则yz λ=y λ1+2204209.1tl b y =×1+y λ>=⨯⨯58.81)8.08.244809.1224故由58.81max ==yz λλ,b 类,678.0=ϕ,MPa MPa A N 8.2023200678.01006.4403=⨯⨯=ϕ<MPa 215 故所选截面满足要求;填板放两块,尺寸取60mm ×145mm ×10mm,则 间距cm i cm l d 8.13027.340406.8138.244=⨯=<==,取90cm; ②杆件dR-RI此杆在R 节点处不断开,采用通长杆件;05.611.402448===x ox x i l λ最大拉力:KN N dR 60.65= ,KN N RI 33.103= 最大压力:KN N dR 63.34-= ,KN N RI 03.31-=再分式桁架中的斜腹杆,在桁架平面内的计算长度取节点中心间距mm l ox 2157=,在桁架平面外的计算长度:mm N N l l oy 5.6399)63.3403.3125.075.0(4314)125.075.0(21=⨯+⨯=⨯+⨯= 选用4632⨯L ,查角钢规格表得2996mm A =,mm i x 6.19=,mm i y 4.29=1507.996.192157<===x ox x i l λ因x λ<y λ,只需求y ϕ;查表得3486.0=y ϕ,则MPa A N y 7.999963486.034630=⨯==ϕσ<MPa 215 拉应力: MPa MPa A N 2157.10399610333<===σ 所选截面满足要求;填板放两块,尺寸取60mm ×83mm ×10mm,则 间距cm i cm l d 4.7896.140409.7137.215=⨯=<==,取75cm; ③ 杆件Bb杆件轴力 KN N 58.339=计算长度 =ox l ×2534=, mm l oy 2534= 选用8752⨯L ,查角钢规格表得22300mm A =,mm i x 8.22=,mm i y 0.35=3509.882.2027<===xoxx i l λ 3504.720.352534<===yoy y i l λ 所选截面满足要求;15067.2174.295.6399<===yoy y i l λ填板放两块,尺寸取60mm ×95mm ×10mm,则 间距cm i cm l d 4.18228.280804.6334.253=⨯=<==,取80cm; ④杆件bD杆件轴力 KN N 24.267-=计算长度 =ox l ×2798=, mm l oy 2798= 选用8752⨯L ,查角钢规格表得22300mm A =,mm i x 8.22=,mm i y 0.35=1502.988.224.2238<===x ox x i l λ,1508.812.342798<===y oy y i l λ x λ>y λ,567.0=x ϕ,MPa MPa A N x 2159.2042300567.0267240<=⨯==ϕσ 所选截面满足要求;填板放三块,尺寸取60mm ×95mm ×10mm,则 间距cm i cm l d 2.9128.240400.7048.279=⨯=<==,取70cm; ⑤杆件Dc杆件轴力 KN N 33.180=计算长度 =ox l ×2778=, mm l oy 2778= 选用8752⨯L ,查角钢规格表得22300mm A =,mm i x 8.22=,mm i y 0.35=3505.978.224.2222<===x ox x i l λ,35037.790.352778<===y oy y i l λ MPa MPa A N 2154.782300180330<===σ 所选截面满足要求;填板放两块,尺寸取60mm ×95mm ×10mm,则 间距cm i cm l d 4.18228.280806.9238.277=⨯=<==,取100cm; ⑥杆件cF杆件轴力 KN N 64.118-=计算长度 =ox l ×3055=2444m, mm l oy 3055=选用8752⨯L ,查角钢规格表得22300mm A =,mm i x 8.22=,mm i y 0.35=1502.1078.222444<===x ox x i l λ,1503.890.353035<===y oy y i l λx λ>y λ,449.0=x ϕ, MPa MPa A N x 2159.1142300449.0118640<=⨯==ϕσ 所选截面满足要求;填板放三块,尺寸取60mm ×95mm ×10mm,则 间距cm i cm l d 2.9128.240404.7645.305=⨯=<==,取cm 80; ⑦杆件Fd杆件轴力 KN N 49.52=计算长度 =ox l ×3035=2444m, mm l oy 3035= 选用4632⨯L ,查角钢规格表得2996mm A =,mm i x 6.19=,mm i y 4.29=3509.1236.192428<===x ox x i l λ,3505.1004.293035<===y oy y i l λMPa MPa A N 2157.5299652490<===σ 所选截面满足要求填板放两块,尺寸取60mm ×83mm ×10mm,则 间距cm i cm l d 8.15696.180802.10135.303=⨯=<==,取110cm; ⑧杆件RG杆件轴力 KN N 13.34=计算长度 =ox l ×1952=, mm l oy 1952= 选用4632⨯L ,查角钢规格表得2996mm A =,mm i x 6.19=,mm i y 4.29=3507.796.196.1561<===x ox x i l λ,3506.644.291952<===y oy y i l λx λ>y λ,688.0=x ϕ,MPa A N x 8.49996688.034130=⨯==ϕσ<MPa 215 所选截面满足要求填板放两块,尺寸取60mm ×83mm ×10mm,则 间距cm i cm l d 8.15696.180801.6532.195=⨯=<==,取70cm; 4竖杆 ①杆件Aa杆件轴力 KN N 50.24-=计算长度 =ox l ×1900=1520m, mm l oy 1900=由于杆件内力较小,按150][==λλ选择,需要回转半径为mm i x 13.10=,mm i y 67.12=选用4562⨯L ,查角钢规格表得2878mm A =,mm i x 3.17=,mm i y 7.26=15086.873.171520<===x ox x i l λ,15034.697.261900<===y oy y i l λx λ>y λ,636.0=x ϕ,MPa A N x 87.43878636.024500=⨯==ϕσ<MPa 215 所选截面满足要求;填板放两块,尺寸取60mm ×76mm ×12mm,则 间距cm i cm l d 2.6973.140403.633.190=⨯=<==,取65cm; ②杆件HR杆件轴力 KN N 99.48-=计算长度 =ox l ×1406=, mm l oy 1406= 选用4562⨯L ,查角钢规格表得2878mm A =,mm i x 3.17=,mm i y 7.26=15002.653.178.1124<===x ox x i l λ,1503.517.261406<===y oy y i l λx λ>y λ,78.0=x ϕ,MPa A N x 53.7187878.0448990=⨯==ϕσ<MPa 215 所选截面满足要求;填板放三块,尺寸取60mm ×76mm ×10mm,则 间距cm i cm l d 2.6973.140408.4636.140=⨯=<==,取50cm; ③杆件Cb杆件轴力 KN N 92.48-=计算长度 =ox l ×2200=1760m, mm l oy 2200= 选用4562⨯L ,查角钢规格表得2878mm A =,mm i x 3.17=,mm i y 7.26=1507.1013.171760<===x ox x i l λ,1503.807.262200<===y oy y i l λx λ>y λ,483.0=x ϕ,MPa A N x 5.115878483.0448920=⨯==ϕσ<MPa 215 所选截面满足要求;填板放三块,尺寸取60mm ×76mm ×10mm,则 间距,2.6973.14040554220cm i cm l d =⨯=<==取60cm; ④杆件Ec杆件轴力 KN N 92.48-=计算长度 =ox l ×2500=2000m, mm l oy 2500= 选用4562⨯L ,查角钢规格表得2878mm A =,mm i x 3.17=,mm i y 7.26=1506.1153.172000<===x ox x i l λ,15024.917.262200<===y oy y i l λx λ>y λ,460.0=x ϕ,MPa A N x 1.121878460.0448920=⨯==ϕσ<MPa 215 所选截面满足要求;填板放三块,尺寸取60mm ×76mm ×10mm,则间距,2.6973.140405.624250cm i cm l d =⨯=<==取65cm; ⑤杆件Gd杆件轴力 KN N 47.73-=计算长度 =ox l ×2800=2240m, mm l oy 2800= 选用4632⨯L ,查角钢规格表得2996mm A =,mm i x 6.19=,mm i y 4.29=1503.1146.192240<===x ox x i l λ,1507.924.292800<===y oy y i l λ x λ>y λ,468.0=x ϕ,MPa A N x 6.157996468.073470=⨯==ϕσ<MPa 215 所选截面满足要求;填板放三块,尺寸取60mm ×83mm ×10mm,则 间距,4.7896.14040704280cm i cm l d =⨯=<==取70cm表 3 屋 架 杆 件 截 面 选 择 表1.下弦设计 1下弦节点b已知采用用E43型焊条,角焊缝的抗拉、抗压和抗剪强度设计值160wf f Mpa ;设“Bb ”杆的肢背和肢尖焊缝mm mm h f 68和=,则所需的焊缝长度为按等肢角钢连接的角焊缝内力分配系数计算:肢背: mm l w 2.1648216087.02339580321=⨯+⨯⨯⨯⨯=,取180mm ;肢尖: mm l w 4.956216067.02339580312=⨯+⨯⨯⨯⨯=,取100mm ;设“bD ”杆的肢背和肢尖焊缝mm mm h f 68和=,则所需的焊缝长度为: 肢背: mm l w 9.1518216087.02267240321=⨯+⨯⨯⨯⨯=,取120mm ;肢尖: mm l w 6.776216067.02267240312=⨯+⨯⨯⨯⨯=,取90mm ;“Cb ”杆的内力很小,焊缝尺寸可按构造确定,取mm h f 5=;根据上面求得的焊缝长度,并考虑杆件之间应有的间隙及制作和装配等误差,按比例绘出节点详图,从而确定节点板尺寸为300mm ×340mm;下弦节点“b ”下弦与节点板连接的焊缝长度为,mm h f 6=;焊缝所受的力为左右两下弦杆的内力差kN 27.32618.42245.685==∆—N ,受力较大的肢背处的焊缝应力为MPa f MPa w f 1603.971234060.7226270332=)—(<=⨯⨯⨯⨯=τ,焊缝强度满足要求;2下弦节点c已知采用用E43型焊条,角焊缝的抗拉、抗压和抗剪强度设计值160wf f Mpa ;设“cD ”杆的肢背和肢尖焊缝mm mm h f 68和=,则所需的焊缝长度为按等肢角钢连接的角焊缝内力分配系数计算:肢背: mm l w 4.838216087.02180330321=⨯+⨯⨯⨯⨯=,取100mm ;肢尖: mm l w 3.566216067.02180330312=⨯+⨯⨯⨯⨯=,取60mm ;设“cF ”杆的肢背和肢尖焊缝mm mm h f 68和=,则所需的焊缝长度为: 肢背: mm l w 4.608216087.02186401321=⨯+⨯⨯⨯⨯=,取80mm ;肢尖: mm l w 3.416216067.02118640312=⨯+⨯⨯⨯⨯=,取60mm ;“cE ”杆的内力很小,焊缝尺寸可按构造确定,取mm h f 5=;根据上面求得的焊缝长度,并考虑杆件之间应有的间隙及制作和装配等误差,按比例下弦节点“c ”绘出节点详图,从而确定节点板尺寸为260mm ×300mm;下弦与节点板连接的焊缝长度为,mm h f 6=;焊缝所受的力为左右两下弦杆的内力差kN 41.15545.86586.741=-=∆N ,受力较大的肢背处的焊缝应力为MPa f MPa w f 16079.371234060.7215541032=)—(<=⨯⨯⨯⨯=τ,焊缝强度满足要求;3下旋节点d已知采用用E43型焊条,角焊缝的抗拉、抗压和抗剪强度设计值160wf f Mpa ;设“Fd 的肢背和肢尖焊缝mm mm h f 68和=,则所需的焊缝长度为按等肢角钢连接的角焊缝内力分配系数计算:肢背: mm l w 6.358216087.0252490321=⨯+⨯⨯⨯⨯=,取80mm.肢尖: mm l w 8.246216067.0252490312=⨯+⨯⨯⨯⨯=,取60mm.设“dR 的肢背和肢尖焊缝mm mm h f 68和=,则所需的焊缝长度为: 肢背: mm l w 5.408216087.0265600321=⨯+⨯⨯⨯⨯=,取80mm.肢尖: mm l w 1.286216067.0265600312=⨯+⨯⨯⨯⨯=,取60mm .“Gd 的内力很小,焊缝尺寸可按构造确定,取mm h f 5=;根据上面求得的焊缝长度,并考虑杆件之间应有的间隙及制作和装配等误差,按比例绘出节点详图,从而确定节点板尺寸为260mm ×340mm;下弦节点“d ”下弦与节点板连接的焊缝长度为,mm h f 6=;焊缝所受的力为左右两下弦杆的内力差kN 05.181.74086.741=-=∆N ,受力较大的肢背处的焊缝应力为MPa f MPa w f 16026.01234060.72105032=)—(<=⨯⨯⨯⨯=τ,焊缝强度满足要求;4下弦节点e1弦杆与拼接角钢连接焊缝计算:下弦与节点板连接的焊缝长度为50cm,mm h f 8=;焊缝所受的力为弦杆的内力kN 81.740=N ,则需焊缝长度为: =+⨯⨯⨯=167.04w ff w f h N l mm 222.698216087.04740810=⨯+⨯⨯⨯,取w l =250mm 拼接角钢长度不小于2⨯250+10=510mm,取540mm;为了保证施焊方便和保证连接焊缝的质量,还需将连接角钢的竖直肢切去Δ=t+mm h f 5+=10+8+5=23mm;2竖杆与节点板连接焊缝计算:按下弦杆内力的15%计算;kN N 12.111%15408107=⨯=设肢背、肢尖焊脚尺寸为6mm,弦杆一侧需焊缝长度为肢背:mm l w 39.671216067.021012.111323=+⨯⨯⨯⨯⨯=,取w l =80mm 肢尖mm l w 28.391216067.021012.111313`=+⨯⨯⨯⨯⨯=,按构造要求,取焊缝长度`w l ≥50mm, 取`w l =60mm3节点板尺寸:按比例绘出节点详图,从而确定节点板尺寸:图14.下弦节点“e ”MPa f MPa w f 16056.911650080.7274081032=)—(<=⨯⨯⨯⨯=τ 焊缝强度满足要求;2上弦设计1上弦节点“B ”“Bb ”杆与节点板的焊缝尺寸和节点“b ”相同;已知: kN 06.440-N =aB设“aB ”杆的肢背和肢尖焊缝mm mm h f 68和=,则所需的焊缝长度为按不等肢角钢短肢连接的角焊缝内力分配系数计算:肢背: mm l w 164.538216087.024********=⨯+⨯⨯⨯⨯=,取170mm ; 肢尖: mm l w 120.056216067.024********=⨯+⨯⨯⨯⨯=,取140mm ; 为了便于在上弦上搁置屋面板,节点板的上边缘可缩进上弦肢背8mm;用槽焊缝把上弦角钢和节点板连接起来;槽焊缝作为两条角焊缝计算,槽焊缝强度设计值乘以的折减系数;计算时可略去屋架上弦坡度的影响,而假定集中荷载P 与上弦垂直;上弦肢背槽焊缝内的应力由下面计算得到:。

单层厂房排架设计例题1 精品

单层厂房排架设计例题1 精品

单层厂房结构课程设计实例1、结构构件选型及柱截面尺寸确定该厂房是某市郊区内的一个高双跨(18m+18m)生产车间。

车间长总36m,纵向柱矩6m,在车间中部,有温度伸缩逢一道,厂房两头设有山墙。

柱顶标高大于8m,故采用钢筋混凝土排架结构。

为了使屋架具有较大刚度,选用预应力混凝土折线形屋架及预应力混凝土屋面板,选用钢筋混凝土吊车梁及基础梁。

厂房的各构选型见表1-1表1-1主要构件选型由图1-1可知柱顶标高是8.4米,牛腿顶面标高为9.0m;室内地面至基础顶面的距离为0.5米,则计算简图中柱顶标高H,下柱高度H l和上柱的高度Hu 分别为:H=12.9m+0.5m=13.4mH1=8.4m+0.5m=6.5mH u=10.7m-6.5=4.2m根据柱的高度,吊车起重量及工作级别等条件,确定柱截面尺寸,见表1-2。

见表1-2 柱截面尺寸及相应的参数2.荷载计算2.1恒载 2.1.1屋盖恒载2222222224.95kN/m 总计0.05kN/m 屋盖钢盖钢 1.9kN/m 板预应力混凝土大型天沟 1.4kN/m 缝)(包括 板预应力混凝土大型屋面 0.4kN/m 厚水泥砂浆20mm 0.05kN/m 一毡毡二油隔气 0.4kN/m 厚水泥珍珠岩保温层100mm 0.4kN/m 厚水泥砂浆20mm 0.35kN/m 二毡毡三油防水灌找平层层找平层层屋架重力荷载为106.0kN/榀,则作用于柱顶的屋盖结构的重力荷载设计值为:410.4kN kN/m 2/1062/246kN/m 95.42.111 m m G G B A2.1.2吊车梁及轨道重力荷载设计值:kN 72.5460.8kN/m kN 8.402.13 m G2.1.3柱自重重力荷载设计值: A 、C 柱:上柱:G 4A =G 4C =1.2×4.0kN/m ×3.35m=16.08kN 下柱: G 5A =G 5C =1.2×4.69kN/m ×9.5m=53.47kN B 柱:上柱: G 4B =1.2×6.0kN/m ×3.35m=24.12kN 下柱: G 5B =1.2×6.94kN/m ×9.5m=79.12kN 各项恒载作用位置如图2-1所示。

(参考资料)单层厂房课程设计计算例题

(参考资料)单层厂房课程设计计算例题

单层厂房课程设计计算书一、总则(一)、设计任务:1、厂房结构布置2、选用标准构件3、排架柱、牛腿及柱下基础设计(二)、设计依据:1、建筑结构荷载规范(GB50009-2001)2、混凝土结构设计规范(GB50010-2002)3、建筑地基基础设计规范(GB50007-2002)4、房屋建筑制图统一标准(GB/T5001-2001)5、建筑结构制图标准(GB/T50105-2001)6、各标准图集7、有关规范、标准、设计手册及教材(三)、设计资料1、该厂房位于北京,地面粗糙度为B 类,该市基本风压为0.45KN/m 2。

基本雪压为0.40KN/m 2,地基土为砂质粘土,承载力标准值为200KN/m 2。

设计基准期为50年,不考虑抗震设防。

厂房跨度为18米,无天窗,长度66m,柱距6m,室内地坪标高为000.0 m ,室外地坪为-0.300m ,车内设两台A5级桥式吊车,相关资料见下表:起重量(t )桥跨l k (m )最大轮压(KN )小车重(t )大车轮距W (m )大车宽B (m )车高H(mm )B 1(mm )吊车总重(t )轨顶标高(m )16/3.216.5156.806.7654.05922233627324.08.852、构造做法及要求:1)、屋架采用18m 梯形钢屋架(含屋盖支撑);吊车梁采用中轻级工作制钢吊车梁(Q235钢)[标准图集SG520-1~2]。

2)、屋面:卷材防水(二毡三油防水层上铺小豆石0.35KN/m 2,20mm 水泥砂浆找平层0.4KN/m 2,100mm 厚加气混凝土保温层0.60KN/m 2,冷底子油一道,热沥青二道0.05KN/m 2,预应力混凝土大型屋面板[标准图集92(03)G410-1-3])。

3)、墙体:370mm 清水砖墙。

采用普通烧结砖。

4)、柱间支撑:标准图集97G3365)钢窗:重0.45KN/m .2型钢和钢板:采用Q235B 钢。

3、采用材料:一般构件:C30;基础:C25;基础垫层:C10。

工业厂房例题

工业厂房例题

单层厂房结构课程设计实例1.结构构件选型及柱截面尺寸确定因该厂房跨度在15--36m之间,且柱顶标高大于8m,故采用钢筋混凝土排架结构。

为了使屋盖具有较大刚度,选用预应力混凝土折线型屋架及预应力混凝土屋面板。

选用钢筋混凝土吊车梁及基础梁。

由图2-54可知柱顶标高为9.6m,牛腿顶面标高为6n;设室内地面至0.5m,则计算简图中柱的总高度H,下柱高度H,和上10.2m 0.5m 10.7m+12.800图2-54厂房剖面图根据柱的高度、吊车起重量及工作级别等条件,可确定柱的截面尺寸,见表2-22。

2-22计算参数柱号截面尺寸/ mm面积/ 2 / mm 惯性矩/mm4自重/ kN/mA, C上柱矩400 400 1.6 10521.3 108 4.0基础顶面的距离为柱高度H,分别为:H l 6m 0.5m 6.5mH u 10.7m 6.5m 4.2m+7.200亠+6.000 -0.150 [亠X O1!L ± 0.000111+11.750+9.600/Mat:.卜」….B)屋盖钢支撑 2.84kN/m 2下 柱 I400 900 100 150 1.875 105195.38 1084.69 B上 柱矩 400 6002.4 10572 1086.0 下 柱I400 1000 100 1501.975 105256.34 1084.94本设计仅取一榀排架进行计算,计算单元和计算简图如图2-55示。

1 , nM ,1i ,0乌1 1 0,i i f *'1a q '0 'L 0'1" 0l^=,1H L 0' 1l-l18004 E -------------A 柱■iMJ图2-55计算单元和计算简图2.荷载计算1.恒载⑴屋盖恒载 绿豆砂浆保护层 二毡三油防水层0.35kN/m 220厚水泥砂浆找平层 20kN/m 30.02m0.40kN/m 2280厚泡沫混凝土保温层8kN/m 30.08m 0.64kN/m 2预应力混凝土大型屋面板(包括灌缝)1.4kN/m 2 0.05kN/m 2总计--- 4- A 活 A、IHA1800B柱屋架重力荷载为60.5kN/榀,则作用于柱顶的屋盖结构的重力荷载设计值 为:■.1i 1L3上=2&启J二卞=「让匚匕3.iJC F 】〔)图2-56荷载作用位置图 ■ «◎ (单位:kN ) 2.屋面活荷载 屋面活荷载标准值为 于前者,故仅按前者计算。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

单层工业房设计一、设计资料:1. 工程概况某造纸车间为一单跨单层钢筋混凝土厂房,厂房总长66m,跨度27m,柱距6m,设有20/5t、10t各一台中级工作级别吊车,轨顶标高+10.1m。

厂房平面图如图(1)2. 设计资料屋面构造:二毡三油防水层(上铺绿豆砂);20mm厚水泥砂浆找平层;100mm水泥膨胀珍珠岩保温层;一毡二油隔气层;20mm厚水泥砂浆找平层;预应力混凝土大型屋面板。

围护结构:240mm厚普通砖墙,双面抹灰;钢框玻璃窗宽×高:4000mm×5100mm 和4000mm×1800lmm。

地面:钢筋混凝土地面,室内外高差150mm。

3.设计基本原始资料自然条件:基本风压为0.5kN/m2,地面按B类,基本雪压为0.3KN/m2,屋面活荷载为0.5kN/m2。

地质条件:场地地面以下0.8内为填土,填土下层4.8m内为粉质粘土,地基承载力特征值为240kN/m2,地下水位为-5.5m。

该工程位于非地震区,不考虑抗震设计。

4. 材料钢筋:箍筋为HPB235级钢筋、受力钢筋HRB335级钢筋。

混凝土:柱采用C40,基础采用C20。

5.设计要求1)初步确定排架结构布置方案;2)对结构上部的标准构件进行选型,并进行结构布置;3)排架的荷载计算和内力分析;4)排架柱的设计;5)柱下独立基础的设计二、构件选型及屋盖布置根据厂房的跨度、吊车起重量的大小、轨顶标高,吊车的运行空间等初步确定出排架结构的剖面如图(2)所示。

为了保证屋盖的整体性,屋盖采用无檩体系。

1.屋面板采用1.5m×6m预应力混凝土屋面板,根据屋面做法求得屋面荷载,采用标准图集92G410(一)中的Y—WB—2,屋面板自重标准值为1.4KN/m2(包括灌缝自重)。

2.天沟板(外天沟排水)选用92G410(三)标准图集中的JGB77—1,自重标准值2.02kN/m。

3.屋架采用预应力混凝土折线形屋架,选用标准图集95G415(三),每榀屋架自重标准值为120kN。

4.屋盖支撑在端部第二开间的屋架端部和跨中设三道垂直支撑、其他跨相应部位设下弦系杆,端头第二开间设下弦横向水平支撑。

5.吊车梁选用95G425标准图集中的先张法预应力混凝土吊车梁,梁高1200mm,每根自重标准值44.2kN,轨道及垫层构造高度200mm,轨道及连接重l kN/m。

6.排架柱排架的上柱截面为矩形, 下柱采用工字形截面。

7. 支撑布置设计采用大型屋面板,可以不设屋架上弦支撑。

根据构造要求,设置相应的屋架下弦支撑,并在跨度中点处布置一道垂直支撑。

见图(3)本设计跨度27m,大于18m,因此需要布置支撑。

柱截面高度h>600mm,下部柱间支撑做成双片,其间距为柱截面高减去200mm,见图(4)。

图(3)屋架下弦支撑图(4)柱的支撑布置三、排架的荷载计算1.排架计算简图的确定(1)确定柱高。

吊车梁顶标高=轨顶标高—轨道构造高度=10.1—0.2=9.9m牛腿标高=吊车梁顶标高—吊车梁高=9.9-1.2=8.7m柱顶标高=轨顶标高+吊车高度H+上部运行尺寸,取为12.6m 上柱高H u=柱顶标高--牛腿标高=12.6—8.7=3.9m全柱高H=柱顶标高—基顶标高=12.6--(--0.6)=13.2m下柱高H l=H--H u=13.2-3.9=9.3m,λ= H u/H=3.9/13.2=0.295(2)初步拟订柱尺寸根据表一的参考尺寸,取上柱b×h=400mm×450mm, 下柱b×h×h f=400mm ×850mm×200mm,截面尺寸如图(5)所示。

图(5)下柱截面尺寸(单位:mm)图(6)排架计算简图(3)参数计算 上柱: 493100375.3450400121mm I u ⨯=⨯⨯= 下柱:233L 25)322500(25300212500300121850400121I ⨯+⨯⨯⨯⨯-⨯⨯-⨯⨯= 41010887.1mm ⨯=比值:16.0==luI I n 排架计算简图如图(6) 2.荷载计算 (1)恒载计算。

1)屋盖结构自重标准值:二毡三油防水层 0.35KN/m 220mm 厚水泥砂浆找平层; 20×0.02=0.4 KN/m 2 100mm 水泥膨胀珍珠岩保温层; 4×0.1=0.4 KN/m 2 一毡二油隔气层; 0.05 KN/m 220mm 厚水泥砂浆找平层; 20×0.02=0.4 KN/m 2 预应力混凝土大型屋面板。

1.4 KN/m 2 g k =3.00 KN/m 2 天沟板 2.02×6=12.12 KN 屋架自重 120KN则作用在一榀横向平面排架一端柱顶的屋盖自重标准值为kN G k 12.315212012.1222760.31=++⨯⨯=mm h e u 75150245015021=-=-=2)柱自重标准值:上柱 G 2k =25×0.4×0.45×3.9=17.55kNmm h h e u l 20024502850222=-=-=下柱 G 3k =25×9.1×[0.2×0.4×2+0.4×0.1+2×kN 4.541.1]025.0)1.04.0(21=⨯⨯+⨯ 注(1.1为考虑下柱仍有部分矩形截面而乘的增大系数)3e =03)吊车梁及轨道自重标准值:G 4k =44.2+1×6=50.2kN4e =800—850÷2=375mm(2)屋面活荷载标准值由《荷载规范》可知,不上人屋面均不活荷载为0.50 KN/m 2,不大于基本雪压,屋面活荷载在每侧柱顶产生的压力为Q 1k =0.5×6×27÷2=40.5 KN(3)吊车荷载标准值 由DSQD 型其参数如下吊车吨位(t ) Q 1k (kN ) Q 2k (kN ) 吊车宽度B (mm ) 轮距K (mm ) P maxk (kN ) P mink (kN )20/5 320 69.77 6055 4100 216 79 10 240 34.61 5980 4050 136 51根据B 与K 及支座反力影响线图(7),可求得图(7) 求D max 时的吊车位置图)]()([43,2max 21,1max ,max y y P y y P D k k k +++=β)]60075.060575.4(136)69.11(216[9.0+++= kN 84.339=)]()([43,2min 21,1min min,y y P y y P D k k k +++=β)]60075.060575.4(51)69.11(79[9.0+++= kN 125=kN Q Q T k k k 7.6)77.69200(1.041)(4132,1=+⨯⨯=+=αkN Q Q T k k k 04.4)61.34100(12.041)(4132,2=+⨯⨯=+=α)]()([432211max,y y T y y T T k k k +++=βkN 4.10)68.004.432.17.6(9.0=⨯+⨯⨯=其作用点到柱顶的距离y=69.09.37.2/,7.22.19.3===-=-u e u H y m h H (4)风荷载标准值。

计算21q q 、时风压高度变化系数按柱顶离室外天然地坪的高度12.6+0.15=12.75m 取值,计算k W 时风压高度变化系数按檐口标高14.9m 取值)(/61.96.05.014.1]8.11.03.23.1[])6.05.0()5.08.0[(14.1)109.14(0.101500.114.10.1)(/62.165.008.15.0)(/60.265.008.18.008.1)1075.12(0.101500.114.10.10210201→=⨯⨯⨯⨯-⨯=-++==---+=→=⨯⨯⨯==→=⨯⨯⨯===---+=m kN B w h h W m kN B w q m kN B w q z k z z s k z s k z μμμμμμμ图(8)风载体型系数(长度单位:mm )排架受荷总图如图(9)图(9)排架受荷总图3.内力计算(1)恒载作用下。

由于单层厂房多属于装配式结构,柱、吊车梁及轨道的自重,是在预制柱吊装就位完毕而屋架尚未安装时施加在柱子上的,此时尚未构成排架结构。

但在设计中,为了与其他荷载项计算方法一致,并考虑到使用过程的实际受力情况,在柱、吊车梁及轨道的自重作用下,仍按排架结构进行内力计算。

在屋盖自重G1k、上柱自重G2k、吊车轨道及连接G4k作用下,由于结构对称、荷载对称,故可简化为如图(10)的计算简图图(10)恒荷载作用下计算简图1)在G 1k 作用下) m -23.63(kN =0.075×-315.12=e G =M 11k 12k ⋅) m -63.03(k N =0.2×-315.12=e G =M 21k 12k ⋅ 2) 在G 2k 作用下) m -3.51(k N =0.2×-17.55= e G =M 22k 22k ⋅ 3) 在G 4k 作用下m)kN 18.83(=0.375×50.2 =e G =M 44k 42k ⋅)叠加以上弯矩M 1k = M 11k =-23.63(m kN ⋅)M 2k = M 12k +M 22k +M 42k =-63.03-3.51+18.83=-47.7(m kN ⋅)已知,295.0,181.0==λn 由规范公式: 72.0)116.01(295.01)16.011(295.0123)11(1)11(12332321=-+--⨯=----⨯=n n C λλ在M 1k 作用下 )(29.12.1364.2372.0111→=⨯==kN H M C R k 由规范公式21.1)116.01(295.01295.0123)11(1132322=-+-⨯=-+-=n C λλ 在M 2k 作用下)(37.42.1371.4723.1222→=⨯==kN H M C R k在G 1k 、G 2k 、G 3k 、G 4k 共同作用下的弯矩图和轴力图如图(11)图(11)恒荷载作用下内力图 图(12)屋面活荷载作用下的计算简图(2)活荷载作用。

1)屋面活荷载作用下:由于Q 1k 作用位置与G 1k 相同)(1.82.05.40)(04.3075.05.4021111211m kN e Q M m kN e Q M k Q k Qkk⋅-=⨯-==⋅-=⨯-==)(74.02.131.821.1)(17.02.1304.372.012211121→=⨯==→=⨯==kN HM CR kN H M C R kk k kQ Q Q Q 在Q 1k 作用下的M 图和N 如图(12)所示 2)吊车竖向荷载作用下: 当D max,k 作用在A 柱时 A 柱m kN e D M kk⋅=⨯==44.127375.084.3394max,max,B 柱m kN e D M k k ⋅-=⨯-==88.46375.01254min,min, 与恒载计算方法相同,可得C 2=1.21 A 柱)(68.11),(68.112.139.11821.11max,2←-=←-=⨯==kN V kN H D C R A k A B 柱)(26.4),(26.42.1388.4621.11min,2→=→=⨯==kN V kN H D C R B kBA 柱与B 柱相同,剪力分配系数5.0==B A ηη)(42.7),(42.726.468.11)(71.3)26.468.11(5.0)(2122→=←-=+-=+=→=+--=+-==kN V kN V V V kN R R V V B A A A B A A A B η内力图如图(13)图(13)吊车竖向荷载作用下内力图3)吊车水平荷载作用下:当T max 向左作用时69.09.32.19.3=-=u H y 295.0,181.0==λn 由规范公式可得当674.0)]11(1[2)2.0416.0(8.126.0335=-+-+-==n n C H y u λλλ时, 当627.0)]11(1[2)1.0243.0(1.227.0335=-+++-==n n C H y u λλλ时,)(57.6,57.64.10632.0632.069.011max,55→===⨯=====kN V V kN T C R R C H y B A k B A u 时,线性插入得考虑空间作用分配系数,由表12-16可以查得85.0=μ)(915.0)(915.066.566.6)(585.5)57.657.6(85.05.0)(212122→=+=→=-=+=←-=+⨯-=+-==kN V V V kN V V V kN R R u V V B B B A A A B A A B A ηT max 向左作用的M 图、N 图如图(14)所示。

相关文档
最新文档