横河流量计说明书(1)

合集下载

Yokogawa FSW-9000 Series流量监测开关说明书

Yokogawa FSW-9000 Series流量监测开关说明书

connection of the FSW-9000 Series are made with 316 SS and the standard enclosure is glass-filled nylon. The FSW-9000 Series can be made with a great variety of process connections such as threaded, flange, or sanitary and is also available in an aluminum enclosure for hazardous environments. Intrinsic safety barriers required for explosion proof areas.
The conical shape of the sensor’s tip means that the probe can be installed at almost any angle in the pipe and that if the probe is misaligned, accuracy will not be affected. The sensing element and
1⁄2 NPT
Glass filled nylon,
1⁄2 NPT conduit, cable gland, and 2 m (6.5') cable
51 mm (2")
FSW-91-R
Flow sensor 330 (FSCN-90 electronics
sold separately)
1⁄2 NPT
Measuring Ranges for FSW-9000 Series

横河电容式电磁流量计

横河电容式电磁流量计

GeneralSpecification 一般规格书CA 100SG/SN,CA200SG/SN电容式电磁流量计ADMAG CA 电磁流量计在超低导电率流体(可低至0.01μs/cm )、粘性流体或高浓度浆液的测量中有着非常完美的表现。

由于ADMAG CA 采用了非接液式电极,它的陶瓷衬里管外面的电极,可通过管子的电容,来检测出流体所产生的电动势。

■特点: ■非接液式的电极·不受粘性流体或高浓度浆液影响·极广的测量范围,导电率的最小值可至0.01μs/cm (15~100mm 通径) ·不必担心流体的泄漏问题 ■能够测量腐蚀性和磨损性介质 ·99.9%高纯度氧化铝陶瓷衬里■转换器采用双腔结构(电器部分与周围隔开),以便于接线■高清晰度背光LCD 液晶显示,便于操作■高精度,精度可达流量的±0.5%(25~100mm 通径)■技术指标: ■电磁流量转换器*注意:对于不带显示器的转换器,必须用手持式终端来设置参数**注意:脉冲输出和报警输出使用相同的接线端,所以这两个功能不能在同一时间使用 输出信号:电流输出:4~20mA DC负载电阻最大为750Ω(通信时为250~600Ω) 半导体触点输出:脉冲输出或报警输出(参数选择)(额定触点:30V DC (关)和200mA (开)) 通信信号(选用)BRAIN 通信信号(叠加4~20mA DC 信号上) 通信线的条件:负载电阻:250~600Ω(包括电缆电阻) 负载电容:最大0.22μF 负载电感:最大3.3mH与电源线间距:≥15cm (避免平行布线) 接收仪表的输入阻抗:≥10k Ω(在2.4kHz 时) 最大电缆长度:2km (使用“CEV ”电缆时)瞬时流量量显示功能:(仅用于带显示器的转换器)流量既可用流量单位显示,也可用量程百分比显示累积流量显示功能:(仅用于带显示器的转换器)只要设定一个积算系数,可以显示用任何流量单位表示的累积值 量程范围设定功能:可以通过设定体积单位、时间单位、流量值和流量计通径来设定体积流量体积单位:加仑,桶(=158.987L ),m 3,L ,cm 3 时间单位:秒、分钟、小时、天 流量计通径:mm ,inch 失电数据保护:由EEPROM 贮存数据,不需要备份电池 阻尼功能:可设定范围从1秒~200秒(63%响应时间) 脉冲输出功能:通过设定一个脉冲系数就可以输出用任何单位表示的脉冲量脉冲宽度:占空比50%或固定脉冲宽度(0.5,1,20,33,50或100ms )供用户选择输出速率:0.0001-1000PPS (选择脉冲输出时)报警输出功能:在有警告产生时显示警告信号(通常被关闭) 自诊断功能:(仅用于带显示器的转换器)转换器失灵,流量管损坏,设定错误等都可以被诊断并且显示出来 接线口:ANSI 1/2NPT 内螺纹,DIN Pg13.5内螺纹,ISO M20*1.5内螺纹,JIS G1/2(PF1/2)内螺纹 端子连接:M4螺钉 外壳材料:铝合金 涂层:聚氨酯防腐涂层转换器盖子:深海藓绿(蒙赛尔色系0.6GY3.1/2.0) 转换器外壳:乳白色(蒙赛尔色系2.5Y8.4/1.2) 防护结构:IP67、NEMA4X ■测量管结构:IP67、NEMA4X 通径:15,25,40,50,80,100,150,200mm 涂层:15~100mm 通径:无(不锈钢表面)150、200mm 通径:聚氨酯防腐涂层,乳白色(蒙赛尔色系2.5Y8.4/1.2) 测量管材料:外壳:不锈钢(15mm :SCS11,25~200mm :SUS304) 接液部分材质: 衬里:氧化铝陶瓷接地环:不锈钢(SUS316),哈氏合金C276或等同材料,钛注:哈氏合金是海恩斯公司的注册商标 垫圈:聚四氟乙烯垫圈 电极结构:无接液型 接地电阻:≤100Ω防爆性能:(仅限15~100mm 通径) 通过FM ,CSA ,JIS 认证■基本性能 精确度:15~100mm 通径:保证精确度(流体导电率≥0.1μs/cm )150、200mm 通径:保证精确度(流体导电率≥1μs/cm )重复性:流量值的±0.1%(最小1mm/s ) 最大功耗:14W (包括传感器和转换器) 绝缘电阻:在500V DC 时,电源与接地端之间的绝缘电阻为100M Ω在500V DC 时,电源与各输出端之间的绝缘电阻为100M Ω在100V DC 时,各输出端和接地端之间的绝缘电阻为20M Ω绝缘强度:1500V AC (电源与接地端间耐压1分钟)警告在进行电压击穿测试、绝缘电阻测试或其他无电源的电器测试时,请在电源关闭后等待10s 再打开外壳的盖子。

YOKOGAWA ROTAMASS 3系列科里奥利质量流量和密度计 规格说明书

YOKOGAWA ROTAMASS 3系列科里奥利质量流量和密度计 规格说明书

通用规格说明书横河电机株式会社GS 01R04B04-00C-C第九版ROTA MASS 系列 科里奥利质量流量和密度计RCCT39/XR RCCT34-39/IRRCCS30-33RCCR31RCCF31+RCCS34-39/IR目 录特点1测量原理1性能规格2正常工作条件3机械规格4电气规格5远程电缆规格5危险区域规格6压力损失9规划和安装提示10尺寸12型号,后缀代码和可选项代码18ROTAMASS质量流量计分一体型和分离型两种类型,每种类型都有高精度的数字信号处理电路,确保精确而稳定的质量流量测量。

ROTAMASS使用隔爆型转换器壳体和相应的本安型检测器,以适用于危险区域。

ROTAMASS的信号处理电路,防护外壳以及检测器对外部应力和振动的特殊隔离系统,使它在实际应用中表现出卓越的性能。

测量原理根据科里奥利原理测量质量流量,几乎所有的流体都可测量,包括多相流体,高粘度液体(浆糊和泥浆)和气液混合体。

若测量特殊液体(如磨料或高腐蚀性液体)和气体,请联系横河电机中国公司。

特点几乎可测量所有流体,包括高粘度液体,泥浆和多相流体 可提供现场安装和架装的分离型转换器 高精度的数字信号处理使测量精确稳定特殊的检测器隔离系统大大减少外部应力和振动的干扰 简单的测量流路便于自动排空和清洗,可用于食品行业 在大量程下能确保高精度和高稳定度 精确的密度测量,误差小于±0.0005g/cm 3 测量溶液、悬浊液和乳浊液的浓度(如含水率,纯油计算) 两个模拟量输出,两个脉冲量输出或状态输出和 一个状态输入作为标准I/O多种防爆认证(ATEX,FM,IECEx,GOST/RTN,GOST K等) 温度范围:-200℃~+350℃ 基于微处理器的高性能断电期间EEPROM保存设定的参数和累计量高清晰LCD显示 HART通信功能可选基金会现场总线通信(参见GS 01R04B05-00ENE) 可选本安输出 可选不同的测量管材料提供EN,ASME或JIS标准法兰,或根据要求提供···················横河电机株式会社 版权所有 00GS 01R04B04-00C-C性能规格型号- 分离型检测器RCCS30~33:双管道,低流量设计- 分离型检测器RCCS34~39/XR:2管道设计- 分离型现场安装转换器RCCF31- 分离型架装转换器RCCR31- 一体型RCCT34~39/XR:双管道设计被测流体:液体,气体或泥浆可测参数:质量流量,密度,温度以及由这些参数换 算出的值:浓度,体积流量和净流量质量流量测量表1:测量范围类型RCCS30RCCS31RCCS32RCCS33Qmax t/h 0.10.30.6 1.5Qnom t/h 0.0450.170.370.9类型RCCx34RCCx36RCCx38RCCx39RCCx39 /IR RCCx39 /XR Qmax t/h 51750170300600Qnom t/h2.71032100250500Qnom是指压损为1bar时水的流速。

Yokogawa FD-7000 非侵入式超声流量计说明书

Yokogawa FD-7000 非侵入式超声流量计说明书

E-13U N on-Invasive Design, Easy to Install, No System DowntimeU P owered by Rechargeable Internal Battery (Included) or AC Line PowerU O perates with Semi-Clean Liquids, Emulsions and SlurriesU D igital Flowrate Indicator Plus 8-Digit TotalizerU 4 to 20 mA Output StandardU E asy-to-Use Data Entry KeypadU N EMA-4X ABS Waterproof EnclosureU NIST Certificate Standard significant quantities of suspended particles or gas bubbles to reflect sound signals. Now, with the model FD-7000 ultrasonic flowmeter, this is no longer required. When the FD-7000 is used to measure the flow of liquids containing suspended solids or bubbles, the transducers are mounted on a straight run of pipe in the same manner as other ultrasonic meters. In applications where insufficient “reflectors” exist (a condition indicated by a low reading on the FD-7000’s flow analyzer bar graph), the transducers are relocated to a point in the piping where non-symmetrical hydraulic turbulence will be present—ideally just downstream of a 90° elbow. The FD-7000’s unique digital filtering system and signal recognition circuitry transforms the reflections from this non- symmetrical, and not necessarily linear, turbulence into a useable and linear data format.A backlit, 2 line by 20 character, alphanumeric LCD offers simultaneous flowrate and totalizer displays.The FD-7000 is designed for ease of use in the field. Only a few simple keypad entries are required to con-figure the flowmeter for any given pipe and flow conditions.The encapsulated, submersible design of the transducer sensor head allows it to be easily mounted to the pipe surface with the coupling compound and elastic bands that are supplied with the unit. A 6 m (20') retractable cable for connection to the transmitter/ indicator unit is supplied as as integral part of the sensor. The FD-7000 sensor is utilized on pipes that range in internal diameter from 25 mm to 1.5 m (1 to 60").Flowrates can be measured in smaller pipes from 6 to 25 mm (1⁄4 to 1") in diameter with use of the small pipe sensor, model FD-7000-S1.FD-7000 shown smaller than actual size.FD-7000Versatile Multi-liquid ultrasonic FlowMeters enhanced doppler designc o m p l e t e w i t h p o r t a b l e n sd u ce rE-14E FD-7000-STD, replacement sensorfor line sizes 25 to 1524 mm (1 to 60") shownsmaller than actual size.SPECIFICATIONS System Accuracy: ±2% of FS Velocity Range: 0.15 to 6.2 MPS (0.5 to 20 FPS) Measuring Units: FPS, GPM, MGD Linearity: ±0.2% FS Repeatability: 0.4% of FS Flow Rate Display: 6-digit LCD Totalizer Display: 6-digit LCD (resettable)Outputs: 4 to 20 mA into 600 Ωmax., isolated Power Requirements:115 Vac ±10%, 50/60 Hz, 20 VA max. (standard); 230 Vac 50/60 Hz (optional). Internal gel cell battery provides 8 hrs. of continuous operation Liquid Requirements: Full-pipe,low-viscosity (water-like) liquidComes complete with operator’s manual, 2 transducers, couplant, power cord, NIST certificate and gel cell battery.Ordering Example: FD-7000, ultrasonic flowmeter.Required pipe mounting configuration.Transmitter/Indicator Operating Temperature: -30 to 70°C (-22 to 158°F)Sensor Operating Temperature:-40 to 121°C (-40 to 250°F)Dimensions: 432 L x 279 W x 203 mm H (17 x 11 x 8")Weight:10 kg (22 lb)Enclosure: NEMA-4X (IP65)。

Yokogawa DPF60数字流量计、积分总计器与批次控制器说明书

Yokogawa DPF60数字流量计、积分总计器与批次控制器说明书

M-211⁄8DIN RATEMETERS, TOTALIZERS, AND BATCH CONTROLLERSFor Voltage and Current InputsThe DPF60 is a combinationmicroprocessor-based digital rateindicator and integrating totalizer.It accepts inputs of 4 to 20 mA,0 to 20 mA, 0 to 5 V, or 1 to 5 V and can be scaled for engineering unitsdirectly from the NEMA 4X (IP66)rated front panel without tweakinginternal potentiometers. The dualstandard 5 A (@ 250 Vac) relays can be assigned to the ratemeter, or tothe totalizer, or one relay to each for batch control and rate alarm.The display features a floatingdecimal point that moves left or right depending on how many “significant figures” the user has selected. In the totalizer mode, 6-digits can bedisplayed. The unit is fully scalable from 0 to 59,999, which indicates the flow rate represented at 20 mA. A peak and valley feature allows the user to call up the recent high and low readings.A square-root extracting input is optional on all units for use with differential pressure flowmeters,such as orifice plates and pitot tubes.With the DPF66, the user can toggle between rate of flow and total flow (6-digits) from the front panel. The rate display is selectable for units per second, minute, or hour,and the totalizer integrates in the same engineering units. The DPF65displays just total flow, while the DPF64 only displays rate of flow.SPECIFICATIONS Accuracy:±0.15% FS for rate and total Temperature Range:Operating:5 to 54°C (41 to 129°F)Storage:-40 to 93°C (-40 to 199°F)Relay Output:2 SPDT relays, 5 A @250 Vac; relays latch or auto-recycle after 0.1 to 99.9 s Power:94 to 126 Vac, 50/60 Hz (or 12 to 24 Vdc) standard; 187 to 253 Vacor 12 to 24 Vdc optional Display: 15 x 8 mm (0.6 x 0.32") LED—6-digits total, 5-digits rate Standby:Non-volatile RAM retains scale settings, presets, output status andtotal flow up to 1 year without power Regulated Power Output: ±5%24 Vdc @ 50 mAOrdering Examples:DPF64-RS232,ratemeter/ batch controller with RS232 output,$289 + 79 = $368.OCW-3, OMEGACARE SM extends standard 2-year warranty to a total of 5 years ($105), $368 + 105 = $473.DPF64-SQRT,digital ratemeter with square root extraction option, $289 + 79 = $368.DPF66 1⁄8DIN, $420, shown actual size.ߜFront-Panel Programmingand Scaling ߜRate and Totalin One Unit ߜRemote orFront-Panel Reset ߜRelays Latch orAuto-RecycleߜZero and Span Adjustable ߜRate Alarm Acts asWindow Alarm with Hysteresis Around Setpoint ߜAnalog Output OptionalDPF60 Series Starts at$OMEGACARE SM extended warranty program is available for models shown on this page.Ask your sales representative for full details when placing an order. OMEGACARE SMcovers parts, labor and equivalent loaners.Panel Cutout: 45 H x 92 mm W(1.772 x 3.622"); DIN standard; 112 mm (4.4") depthCANADA www.omega.ca Laval(Quebec) 1-800-TC-OMEGA UNITED KINGDOM www. Manchester, England0800-488-488GERMANY www.omega.deDeckenpfronn, Germany************FRANCE www.omega.frGuyancourt, France088-466-342BENELUX www.omega.nl Amstelveen, NL 0800-099-33-44UNITED STATES 1-800-TC-OMEGA Stamford, CT.CZECH REPUBLIC www.omegaeng.cz Karviná, Czech Republic596-311-899TemperatureCalibrators, Connectors, General Test and MeasurementInstruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References,Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes andAssemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, WirePressure, Strain and ForceDisplacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, PressureReference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators,Strain Gages, Torque Transducers, ValvespH and ConductivityConductivity Instrumentation, Dissolved OxygenInstrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis InstrumentationHeatersBand Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and SwitchingDevices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular HeatersFlow and LevelAir Velocity Indicators, Doppler Flowmeters, LevelMeasurement, Magnetic Flowmeters, Mass Flowmeters,Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding FlowmetersData AcquisitionAuto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data LoggersPlug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers。

横河RAMC金属浮子流量计中文说明书

横河RAMC金属浮子流量计中文说明书


,
。、

,
RAMC
,

2-2 “ ”。
VDI/VDE3513。
3-2
(-E,-H)

RAMC
6~9mm

, RAMC
,
,
1.5mm2。
。 。
,
,
,
PG11
, 。
, RL 500Ω 。
RL, : 2/3
RAMC RL=(U-13.5V)/20mA, 4
RAMC,
2
3
2
,“-” “A” ,
“+”、“-” “A” 。 。
SI SI SI ..

/A12
(US)
m3 l Nm3 Nl t kg scf gal
F1-:
F2-: F3-: F4-: F5-:
F11: F12:
F13:
F14: F15: F21:
F31: F32: F33: F34:
F41: F51:On/Off F52-5:
F11-1: F11-2: F11-3:%
Euro F12-1: m3 F12-2: 1 F12-3: Nm3 F12-4: N1 F12-5: t F12-6: kg
( EU
/Kn)

ATEX,94/9/EG
1 (2 ) 2 。


IP54。


RAMC, 。
RAMC
(
( 10 )),RAMC
。,






(
( 10 ))。


EEPROM。
RAMC-E/NS1 -H/NS1

横河电磁流量计资料

横河电磁流量计资料

General Specification 一般规格书 AE100MG/MN/MH/SC,AE200MG/MN/MH/SC,AE300MG/MN 一体型电磁流量计AE14 电磁流量转换器AE100DG/DN/DH,AE200DG/DN/DH,AE300DG/DN分离型电磁流量传感器AE100/200/300[Style:S2], AE14[Style:S1]ADMAG系列电磁流量计是横河公司在流量仪表领域中多年经验的结晶,其设计与横河公司质量控制体系保证了产品的高精度和高可靠性,ADMAG AE是由ADMAG系列改进而来的。

ADMAG AE 的外壳分为两腔,它将电器部分与周围隔开以便于接线。

ADMAG AE采用双频励磁,具有快速响应和消除输出噪声功能,而且可采用陶瓷衬里,从而使得该电磁流量计的应用更加广泛。

■特点:■双频励磁技术所带来的快速响应和高稳定性■高精确度,指示值的0.5%■双腔外壳将电器部分与周围隔开以便于接线■交、直流电源均可使用(100V/200V)■用于24V直流的4芯电缆■高清晰度LCD背光显示■99.9%高纯度氧化铝陶瓷衬里■完善的防漏液保护——铂氧化铝陶瓷合金电极和陶瓷衬里■压力容器等级97/23/EC■技术指标:■用于AE100MG/MN/SC/MH,AE200MG/MN/SC/MH,AE300MG/MN的电磁流量转换器AE14注1:对于不带显示器的转换器,必须用手持式终端来设置参数注2:脉冲输出和报警输出使用相同的接线端,所以这两个功能不能在同一时间使用注3:请参照GS01E07F01-00C现场通讯类型(/FB)输出信号:(注3)电流输出:4~20mA DC (负载电阻最大为750Ω) 半导体触点输出:脉冲输出或报警输出(参数选择) (额定触点:30V DC(关)和200mA(开)) 通信信号(选用)(注3)BRAIN或HART通信信号(叠加4~20mA DC信号上) 负载电阻:(包括电缆电阻)BRAIN:250~600ΩHART:230~600Ω取决于环路中的其它设备(多点模式)负载电容:最大0.22μF负载电感:最大3.3mH与电源线间距:≥15cm(避免平行布线)接收仪表的输入阻抗:≥10kΩ(在2.4kHz时)最大电缆长度:2km(使用“CEV”电缆时)瞬时流量量显示功能:(仅用于带显示器的转换器) 流量既可用流量单位显示,也可用量程百分比显示 累积流量显示功能:(仅用于带显示器的转换器) 只要设定一个积算系数,可以显示用任何流量单位表示的累积值阻尼功能:(注1)可设定范围从1秒~200秒(63%响应时间)量程范围设定功能:(注1)可以通过设定体积单位、时间单位、流量值和流量计通径来设定体积流量体积单位:加仑,桶(=158.987L),m3,L,cm3时间单位:秒、分钟、小时、天流量计通径:mm,inch脉冲输出功能:(注2)(注3)通过设定一个脉冲系数就可以输出用任何单位表示的脉冲量脉冲宽度:占空比50%或固定脉冲宽度(0.5,1,20,33,50或100ms)供用户选择输出速率:0.0001-1000PPS(选择脉冲输出时)状态输出功能:(注2)(注3)在参数设定中,可以选择下述中的一个·自动双范围状态输出自动双范围选择·正、反流向状态输出直接测量正向和反向流量·积算开关状态输出:当内部积算值超过设定值时,状态触点就改变状态·下限报警:流量小于下限设定值报警报警输出功能:(注2)(注3)在有警告产生时显示警告信号(通常被关闭)自诊断功能:(注1)转换器失灵,流量管损坏,设定错误等都可以被诊断并且显示出来失电数据保护:由EEPROM贮存数据,不需要备份电池接线口:ANSI 1/2NPT内螺纹,DIN Pg13.5内螺纹,ISO M20*1.5内螺纹,JIS G1/2内螺纹端子连接:M4螺钉外壳材料:铝合金涂层:聚氨酯防腐涂层盖子:深海藓绿(蒙赛尔色系0.6GY3.1/2.0)外壳:乳白色(蒙赛尔色系2.5Y8.4/1.2)防护结构:IP67,NEMA4X,JIS C0920水密性防护安装(AE14):2英寸管道安装■测量管AE100MG/MN/SC/MH,AE200MG/MN/SC/MH,AE300MG/MN;AE100DG/DN/DH,AE200DG/DN/DH,AE300DG/DN 结构:IP67,NEMA4X,JIS C0920防浸水型通径:**65和125mm衬里为PFA只有CENELEC ATEX涂层:接线盒(AE***D):聚氨酯防腐涂层盖子:深海藓绿(蒙赛尔色系0.6GY3.1/2.0)外壳:乳白色(蒙赛尔色系2.5Y8.4/1.2)壳体2.5~100mm通径:无(不锈钢表面)125~400mm通径:,乳白色(蒙赛尔色系2.5Y8.4/1.2)测量管材料:2.5~15mm通径:外壳:不锈钢(SCS11)法兰(仅15mm):不锈钢(SUS304)管子:不锈钢(SCS13)或氧化铝陶瓷(99.9%)接线盒:铝合金(AE***D)25~100mm通径:外壳:不锈钢(SCS304)法兰:不锈钢(SUS304)管子:不锈钢(SUS304)*或氧化铝陶瓷(99.9%) 接线盒:铝合金(AE***D)125~400mm通径:外壳:碳钢法兰:碳钢管子:不锈钢(SUS304)*或氧化铝陶瓷(99.9%——仅限150和200mm通径)接线盒:铝合金(AE***D)*仅对于PFA和聚氨酯衬里接液部分材质:衬里:PFA,氧化铝陶瓷,聚氨酯电极:不锈钢(SUS316L),哈氏合金C(相当于哈氏合金C-276),钛,钽,铂铱接地环:不锈钢(SUS316),哈氏合金C(相当于哈氏合金C-276),钛,钽,铂铱垫圈:·VALQUA#7020:四氟乙烯树脂和填充物(在流量管管体和接地环之间;陶瓷衬里)·VALQUA#4010:四氟乙烯橡胶(在流量管管体和接地环之间;附加规格/FRG)·非石棉连接片外壳带四氟乙烯树脂(在接地环和管道法兰之间。

横河AXF电磁流量计说明书

横河AXF电磁流量计说明书

上海数捷电气有限公司联系人丗胡先生 •i手机丗137********•j联系电话丗021-********-23传真丗021-******** E-mail•Fhxc@QQ:904091685電磁流量計操作說明書1.基本操作程序資料之設定可由SET,SHIFT,及鍵來變更.AXFA11亦可使用手提BRAIN Terminal(BT200)或HART 通信器設定.NOTE(1) 於保護蓋之玻璃視窗上使用這些按鍵.(2) 玻璃視窗上如有髒污,灰塵,或其他物質時,請用軟質乾淨的布料擦拭.(3) 穿戴髒污的手套操作,可能使按鍵反應異常1.1操作盤架構及功能(1) 資料顯示區依參數設定可顯示第一行(Display Select 1),第二行(Display Select 2),第三行(Display Select 3).每行右方以反白字體顯示對應該行之內容.(2) 按鍵設定操作SET: 往下移動項目層,選擇,或確認.SHIFT+SET: 往上移動項目層(按著SHIFT 鍵時,再按SET 鍵)移動游標向下(參數選項)或 增加數值(數值參數)SHIFT: 移動游標向右(數值參數)移動游標向上(參數選項)(3)顯示項目(4) 反白字體顯示(1) 資料顯示區(3) 顯示項目(2) 設定開關(紅外線觸控開關)顯示項目及反白字體指示瞬間流量: %實際瞬間流量實際瞬間流量: mA 條狀圖指示實際瞬間流量正向累積流量逆向累積流量正逆向偏差累積流量儀表標號電極附著診斷通信通信型式顯示瞬間流量之百分比顯示瞬間流量之讀值顯示瞬間流量電流輸出顯示瞬間流量之百分比條狀圖顯示正向累積流量顯示逆向累積流量顯示正逆向累積流量間之偏差量顯示儀表標號( 16個字元 )以條狀圖顯示電極附著狀況1.2顯示單元設定方法NOTE於改變任何設定之前請確認詳細之相關參數設定內容1.2.1顯示模式 → 設定模式當電源啟動時即進入顯示模式,且依下列步驟進入設定模式顯示例 : 顯示模式至設定模式步驟條狀圖指示瞬間流量按住鍵2 秒鐘同時按鍵和於設定模式回到顯示模式時 , 輸入模式將在一分鐘內被省略開始顯示模式顯示模式輸入模式(2秒或多)主項參數搜尋模式副項參數搜尋模式參數搜尋模式參數更換模式設定模式按著SHIFT鍵時,再按SET鍵實際瞬間流量﹝FR ﹞正向累積流量﹝FTL ﹞鍵並選擇[ YES ] , 進入設定模式銀幕顯示系統是否進入設定模式反白字體為游標位置指示目前選擇的項目按整個銀幕點滅要求確認此時再按一次確認所選之項目系統進入設定模式可選擇參數設定整個步驟是從顯示模式變為參數搜尋模式參數搜尋模式設定模式1.2.2設定模式當設定模式依照1.2.1所述被啟動,如在十分鐘內無任何操作時,系統自動回復至顯示模式 .1.3參數設定步驟AXFA11 常用的參數已一起群組在表單 B 中的Easy Setup . 本節提供B : Easy Setup 之參數設定步驟 .1.3.1( 例 ) 選擇型式資料 : 流量單位本例敘述流量單位設定B21 : Base Flow Unit ( 將 m3 改為 l [ Liter ] )此銀幕已在參數搜尋模式1. 選擇型式2. 數字型式3. 字元型式在預設清單中選擇所須之資料項目設定數值及小數點資料是由字元組合計16個字元詳下表開始主項目參數搜尋模式設定模 主項目參數按鍵進入 B : Easy Setup .此銀幕已在副項目參數搜尋模式按 鍵,使游標移至B21 : Base Flow Unit游標已移至 B21 : Base Flow Unit ( 副項目選擇畫面 ( A ) )此銀幕已用 鍵叫出參數更換模式按 鍵,使游標移至欲選擇之單位項目選定之後按 鍵整個畫面點滅要求確認再按一次 鍵系統自動回至副項目選擇畫面 ( A )主項目 副項目參數主項目 主項目主項目目前之單位設定可選擇之單位可選擇之單位目前之單位設定 副項目選擇 ( A )副項目參數搜尋模式參數更換模式副項目參數搜尋模式1.3.2( 例 ) 數字型式資料 : 流量範圍本例敘述流量範圍設定B23 : Flow Span ( 將 100 l/min 改為 120 l/min )此銀幕已在副項目參數搜尋模式按 鍵,使游標移至B23 : Flow Span游標已移至 B23 : Flow Span ( 副項目選擇畫面 ( B ) )按 鍵進入參數更換模式點滅的位數可變更NOTE用 鍵移動位數用 鍵變更數值及小數點位置變更至 120 l/min 步驟如下按 鍵機游標移至10位數按 鍵將數值變更為2設定完成後按 鍵設定模 主項目參數開始主項目參數搜尋模式副項目參數搜尋模式參數更換模式主項目 副項目參數主項目 副項目選擇 ( B )按鍵進入B : Easy Setup .上述步驟之後畫面將會點滅再按一次 鍵 , 確認數值變更為120 l/min .系統自動回至副項目選擇畫面 ( B )NOTE輸入值超出有效選擇範圍時 , 顯示" Out of range . Touch any key . "之訊息NOTE小數點位置設定超出有效選擇範圍時 ,顯示 " Invalid value . Touch any key . "之訊息1.3.3( 例 ) 字元型式資料 : 儀表標號本例敘述流量範圍設定C20 : Tag No. ( 將 "FI-1101" 改為 "FI-1201" )按 鍵,使游標移至C : Basic Setup游標已移至 C : Basic Setup 按 鍵進入 C : Basic Setup副項目參數搜尋模式主項目 副項目選擇 ( B )錯誤的 設定錯誤的 設定設定模 主項目參數開始主項目參數搜尋模式設定模主項目參數上述步驟完成後游標會定位在C10 :Tag No. ( 副項目選擇畫面 ( D ) )按 鍵進入參數更換模式游標會在要號之左方點滅此例要設定"FI-1201",按 鍵移動由標至百位數位置按 鍵將數值變更為 2再按 鍵上述步驟之後畫面將會點滅再按一次 鍵 , 確認標號變更為"FI-1201"系統自動回至副項目選擇畫面 ( D )在使用( 鍵和 鍵 )後,返回顯示畫面,如有設定顯示儀表標號,則可確認所變更的內容在 Display Select 3 選擇 Tag No. 顯示副項目參數搜尋模式參數更換模式副項目參數搜尋模式主項目副項目選擇 ( D )主項目 副項目選擇 ( D )目前之設定值變更值目前之設定值參數清單總覽1.A 項 ( 清單 A ) : 顯示項目 - Display Items2. B 項 ( 清單 B ) : 簡易設定項目 - Easy Setup Items瞬間流量 % 顯示瞬間流量顯示瞬間流量 mA 顯示正向累積流量顯示逆向累積流量顯示正逆向累積流量偏差顯示顯示自我檢查結果選擇語言顯示與 H30 連結設定阻尼時間,與 C11 連結設定流量單位與 C40 連結設定時間單位與 C41 連結設定流量範圍單位為 B22/B23 ,與 C42 連結選擇瞬間流量顯示之小數點位置與 C43 連結選擇每一脈波之流量單位用於累積流量顯示與 D10 連結設定每一脈波之流量與 D11 連結選擇每一脈波之流量單位用於脈波輸出與 E10 連結設定每一脈波之流量與 E11 連結選擇顯示幕第一行之顯示方式與 H10 連結選擇顯示幕第二行之顯示方式與 H11 連結選擇顯示幕第三行之顯示方式,與 H12 連結選擇是否執行自動零點調整,與 M10 連結顯示自我檢查結果3. C 項 ( 清單 C ) : 基本設定項目 - Basic Setting Items設定儀表標號,可達16個字母設定阻尼時間,與 B20 連結選擇雙頻激磁之測量模式設定雙頻激磁之低頻計器係數設定雙頻激磁之高頻計器係數設定增強型雙頻激磁之低頻計器係數設定增強型雙頻激磁之高頻計器係數選擇連接之流量計型式選擇流量計之尺寸單位設定流量計管徑設定流量單位與 B21 連結設定時間單位與 B22 連結設定流量範圍單位為 B22/B23 ,與 B23 連結選擇瞬間流量顯示之小數點位置與 B24 連結3. D 項 ( 清單 D ) : 累積設定項目 - Total Setting Items 顯示自我檢查結果顯示流量範圍設定之流速選用質量流量時,請選擇密度單位設定密度值選擇是否使用特殊之流量單位設定特殊單位,可設8個字元設定特殊流量範圍顯示自我檢查結果選擇每一脈波之流量單位用於累積流量顯示與 B30 連結設定每一脈波之流量與 B31 連結選擇累計顯示之小數點位置設定流量在多少(%)範圍內時停止流量累計功能設定積算之"啟動","停止", "正逆向預設累計"功能設定積算之預設累計值8 位數中之前 6 位數設定積算之預設累計值8 位數中之後 2 位數設定積算之切換值8 位數中之前 6 位數設定積算之切換值8 位數中之後 2 位數選擇是否使用特殊之積算單位設定特殊積算單位,可設個字元3. E 項 ( 清單 E ) : 脈波設定項目 - Pulse Setting Items選擇每一脈波之流量單位用於脈波輸出與 B32 連結設定每一脈波之流量與 B33 連結脈波寬度設定設定流量在多少(%)範圍內時,停止脈波輸出功能設定脈波輸出動作模式顯示自我檢查結果6. F 項 ( 清單 F ) : 輸出入接點功能設定項目 - Status Function Setting Items選擇 SO1 端子之輸出功能選擇 SO2 端子之輸出功能7.G 項 ( 清單 G ) : 警報設定項目 - Alarm Setting Items 顯示自我檢查結果選擇 SI1 端子之輸入功能選擇 SI2 端子之輸入功能設定 SO1,2 輸出動作模式設定 SI1,2 輸入動作模式設定 #2 正向流量範圍設定 #3 正向流量範圍設定 #4 正向流量範圍設定 #1 逆向流量範圍設定 #2 逆向流量範圍設定 #3 逆向流量範圍設定 #4 逆向流量範圍磁滯寬度設定, 用於測量範圍之自動切換磁滯寬度設定, 用於正逆流樣測量切換設定下限流量警報值設定上限流量警報值設定下下限流量警報值設定上上限流量警報值設定流量警報值磁滯寬度設定警報輸出之動作模式選擇警報發生時之電流輸出形式顯示CPU異常時,電流輸出形式設定警報種類是否可指定指定警報是否為一過載警報指定警報是否為一空管警報指定警報是否為一上上/下下限警報指定警報是否為一附著警報運作時時數顯示最近之警報內容顯示最近之警報發生時間顯示第二近之警報內容顯示第二近之警報發生時間顯示第三近之警報內容顯示第三近之警報發生時間顯示第四近之警報內容顯示第四近之警報發生時間顯示自我檢查結果8.H 項 ( 清單 H ) : 顯示設定項目 - Display Setting Items選擇顯示幕第一行之顯示方式與 B40 連結選擇顯示幕第二行之顯示方式與 B41 連結選擇顯示幕第三行之顯示方式,與 B42 連結選擇顯示週期選擇語言顯示與 B10 連結顯示自我檢查結果9.J 項 ( 清單 J ) : 輔助功能設定項目 - Auxiliary Function Setting Items設定電流在多少(%)範圍內時,輸出 4 mA設定電流輸出下限值設定電流輸出上限值設定流量方向減少輸出變動之等級設定設定不感帶時間,減少輸出變動, 0 - 不動作設定是否支援脈衝流量之測量選擇內部頻率是否與電源同步顯示電源頻率設定電源頻率備忘區備忘區備忘區軟體版本顯示自我檢查結果10.K 項 ( 清單 K ) : 診斷機能設定項目 - Diagnostic Function Setting Items選擇是否執行電極附著診斷設定 #1 級電極附著之阻抗值設定 #2 級電極附著之阻抗值設定 #3 級電極附著之阻抗值設定 #4 級電極附著之阻抗值顯示電極附著之阻抗值顯示自我檢查結果11.M 項 ( 清單 M ) : 自動零點調整功能設定項目 - Automatic Zero-Adjustment FunctionSetting Items選擇自動零點調整是否執行顯示調整結果或設定零點顯示自我檢查結果12.N 項 ( 清單 N ) : 迴路測試設定項目 - Loop Test Setting Items選擇 正常/測試 模式設定測試輸出值選擇SO1測試狀態選擇SO2測試狀態選擇警報輸出端測試狀態選擇SI1測試狀態選擇SI2測試狀態顯示自我檢查結果13.P 項 ( 清單 P ) : 參數保護項目 - Parameter Protection Items參數顯示限制顯示是否禁止參數覆寫允許正確的密碼輸入並解除寫入保護功能寫入保護功能之密碼設定顯示是否使用一個開玩笑的密碼(Break)顯示自我檢查結果。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
相关文档
最新文档