HJ-4A数显恒温多头磁力搅拌器
丙酸氟替卡松乳膏体外透皮吸收量测定

丙酸氟替卡松乳膏体外透皮吸收量测定丁水生;肖学成;李金;陈凤;李丹【摘要】Objective To establish a high performance liquid chromatography ( HPLC ) method for quantitative determination of fluticasone propionate in percutaneous solution, and investigate the ability of percutaneous penetration of fluticasone propionate cream. Methods Hypersil ODS C18 column (250 mm×4.6 mm,5 μm) was used. Mobile phase was as follows; methanol-1. 15 g·L-1 ammonium dihydrogen phosphate (adjusted to pH 3.5 )-acetonitrile (55 : 35:15 in volume). The column temperature was set at 55℃. The flow rate was 1.0 mL·min-1. The detection wavelength was 240 nm. Improved Franz type diffusion cells were used in, vitro permeation studies and excised minipig' s skins in vitro were used as a transdermal barrier. The concentration of fluticasone propionate in the receptor solution was determined by HPLC to investigate its cumulative permeation quantities at different time points respectively , which were compared with those of the commercial cream. Results The regression equation of penciclovir was linear in the range of 0. 050 2-1.003 0 μg·mL-1(A=47 709.364 7×C+300. 774 4, r=0. 999 8). The average recovery was 99. 58%. A good linear relationship existed between the cumulative penetration quantities and the time. There was no significant difference in the skin permeation quantities between the self-made cream and commercial cream. Conclusion The method was simple, rapid, and accurate. It is a better method to evaluate the characteristics of permeation for fluticasonepropionate.%目的建立丙酸氟替卡松乳膏中体外透皮接收液的高效液相色谱(HPLC)测定方法,研究丙酸氟替卡松乳膏的透皮能力.方法采用Hypersil ODS C18色谱柱(250 mm×4.6 mm,5μm),流动相:甲醇-0.01 mol·L-1磷酸氢二胺(用磷酸溶液调pH至3.5)-乙腈(55:35:15),柱温为55 ℃;检测波长为240 nm,流速1.0 mL·min-1.体外透皮实验采用改良的Franz扩散池,以体外乳猪皮作为透皮屏障,比较自制乳膏与市售乳膏的透皮结果,分别在不同时间点取样测定透皮接收液中丙酸氟替卡松浓度,计算累积透皮量.结果丙酸氟替卡松在0.0502 ~1.0030μg·mL-1浓度范围内峰面积与浓度之间呈良好的线性关系(r=0.9998),回归方程为A=47 709.364 7×C+300.7744,平均回收率99.58%.自制乳膏与市售乳膏的透皮结果差异无统计学意义.结论该检测方法操作简便,快速准确,是考察丙酸氟替卡松乳膏体外透皮吸收量较理想的方法.【期刊名称】《医药导报》【年(卷),期】2012(031)012【总页数】3页(P1613-1615)【关键词】丙酸氟替卡松乳膏;透皮吸收;色谱法,高效液相【作者】丁水生;肖学成;李金;陈凤;李丹【作者单位】广东省佛山市禅城区南庄医院药剂科,528061;湖北中医药大学药学院,武汉430065;湖北中医药大学药学院,武汉430065;湖北中医药大学药学院,武汉430065;湖北中医药大学药学院,武汉430065【正文语种】中文【中图分类】R986;R927.2丙酸氟替卡松具有很强的抗炎和局部血管收缩作用,主要用于治疗银屑病和白癜风。
壳聚糖质活性炭对亚甲基蓝的吸附性能研究

壳聚糖质活性炭对亚甲基蓝的吸附性能研究宋娟;李晓晖;宁喜斌【摘要】Use chitosan to make activated carbon. It studied the effect onthe adsorption capacity of meth-ylene blue,and analyzed the adsorption kinetics and the adsorption isotherm. The results showed that the best adsorption conditions of methylene blue optimum for chitosan activated carbon:crosslinking agent a-mount of 0. 3 g,adsorption time of 60 min,the volume methylene blue of 10 mL,adsorption temperapure of 50℃. The adsorption process coincided with the second order kinetic,Freundlich model could describe the process properly.%用壳聚糖制成活性炭,研究其对亚甲基蓝的吸附能力,并分析了吸附动力学以及吸附等温线。
结果显示,壳聚糖质活性炭对亚甲基蓝最佳的吸附条件为:投入量为0.3 g,吸附时间为60 min,亚甲基蓝体积为10 mL;吸附温度为50℃,吸附过程较为符合二级吸附动力学方程、Freundlich模型。
【期刊名称】《应用化工》【年(卷),期】2014(000)008【总页数】4页(P1446-1448,1452)【关键词】壳聚糖;活性炭;亚甲基蓝;吸附【作者】宋娟;李晓晖;宁喜斌【作者单位】上海海洋大学食品学院,上海 201306;上海海洋大学食品学院,上海 201306;上海海洋大学食品学院,上海 201306【正文语种】中文【中图分类】TQ317.3活性炭是一种比较特殊的碳质材料,是一类具有石墨微晶的无定形的碳,是一种具有丰富孔隙结构和巨大比表面积的良好碳质吸附材料,其中主要化学成分是碳元素,并含有少量的氢、氮、氧及灰分。
磁力搅拌器使用方法

磁力搅拌器使用方法磁力搅拌器是一种常用的实验室设备,广泛应用于化学、生物、医药等领域。
它通过磁力场驱动磁子旋转,从而实现对容器内液体的搅拌和混合。
正确的使用方法不仅可以提高实验效率,还能确保实验安全。
下面将介绍磁力搅拌器的使用方法。
首先,将磁力搅拌器放置在水平台面上,并连接电源。
在使用前,务必检查电源线是否完好,搅拌器是否有损坏,以及磁子是否有松动或损坏。
确保设备完好无损后,可以进行下一步操作。
接下来,准备容器和待搅拌的溶液。
选择合适的容器放置在磁力搅拌器上,注意容器底部必须是平整的,以确保磁子能够正常旋转。
将待搅拌的溶液倒入容器中,注意不要超过容器容积的80%,以防止溢出。
然后,在容器中加入磁子。
通常情况下,磁子的数量应根据容器的大小和液体的粘稠度来确定,一般情况下每毫升液体需要1-2颗磁子。
将磁子均匀地分布在溶液中,避免磁子间相互吸引而聚集在一起。
接着,将容器放置在磁力搅拌器上,并调节搅拌器的转速。
通常情况下,初次搅拌时转速可以设置为中等速度,待液体开始搅拌后再适当调整转速。
在调节转速时,要注意慢慢增加或减小转速,避免突然调整导致液体溢出或磁子脱落。
最后,在使用过程中要随时观察搅拌情况。
确保磁子能够均匀旋转,溶液能够充分混合,避免产生气泡或溢出。
在使用结束后,要及时关闭磁力搅拌器的电源,并将容器从搅拌器上取下,清洗和存放设备。
总之,正确的使用方法能够确保磁力搅拌器的正常运转,保障实验的顺利进行。
在使用过程中,要注意设备的安全和操作的规范,确保实验的准确性和可靠性。
希望以上介绍的磁力搅拌器使用方法能够对您有所帮助。
中国毛虾自溶前后多肽和氨基酸的变化

基金项目:国家重点研发计划(编号:2019YFD0902000)作者简介:祝宝华,男,上海海洋大学在读硕士研究生。
通信作者:李晓晖(1976—),女,上海海洋大学副教授,博士。
E mail:xhli@shou.edu.cn收稿日期:2022 11 29 改回日期:2023 05 11犇犗犐:10.13652/犼.狊狆犼狓.1003.5788.2022.81114[文章编号]1003 5788(2023)09 0148 06中国毛虾自溶前后多肽和氨基酸的变化Changesofpeptidesandaminoacidsin犃犮犲狋犲狊犮犺犻狀犲狀狊犻狊beforeandafterautolysis祝宝华1犣犎犝犅犪狅犺狌犪1 李晓晖1,2,3犔犐犡犻犪狅犺狌犻1,2,3 杨志艳1犢犃犖犌犣犺犻狔犪狀1惠婷婷1犎犝犐犜犻狀犵狋犻狀犵1 徐晨晨1犡犝犆犺犲狀犮犺犲狀1 李 燕1,2,3犔犐犢犪狀1,2,3(1.上海海洋大学,上海 201306;2.上海水产品加工及贮藏工程技术研究中心,上海 201306;3.农业部水产品贮藏保鲜质量安全风险评估实验室,上海 201306)(1.犆狅犾犾犲犵犲狅犳犉狅狅犱,犛犺犪狀犵犺犪犻犗犮犲犪狀犝狀犻狏犲狉狊犻狋狔,犛犺犪狀犵犺犪犻201306,犆犺犻狀犪;2.犛犺犪狀犵犺犪犻犃狇狌犪狋犻犮犘狉狅犱狌犮狋犪狀犱犘狉狅犮犲狊狊犻狀犵犪狀犱犛狋狅狉犪犵犲犈狀犵犻狀犲犲狉犻狀犵犜犲犮犺狀狅犾狅犵狔犚犲狊犲犪狉犮犺犆犲狀狋犲狉,犛犺犪狀犵犺犪犻201306,犆犺犻狀犪;3.犔犪犫狅狉犪狋狅狉狔犳狅狉犚犻狊犽犃狊狊犲狊狊犿犲狀狋狅犳犙狌犪犾犻狋狔犪狀犱犛犪犳犲狋狔狅犳犛狋狅狉犪犵犲犪狀犱犘狉犲狊犲狉狏犪狋犻狅狀狅犳犃狇狌犪狋犻犮犘狉狅犱狌犮狋狊,犕犻狀犻狊狋狉狔狅犳犃犵狉犻犮狌犾狋狌狉犲,犛犺犪狀犵犺犪犻201306,犆犺犻狀犪)摘要:目的:为开发毛虾小分子生物活性肽和氨基酸类产品提供依据。
电子价目表

主要技术参数
出厂价
(元)
HH-S1
单孔水浴锅
水箱尺寸150x150x115mm不锈钢
480
HH-S2
双孔水浴锅
水箱尺寸300x150x115mm不锈钢
520
HH-S14
单列四孔水浴锅
水箱尺寸600X150x115mm不锈钢
780
HH-S16
单列六孔水浴锅
水箱尺寸900x150x115mm不锈钢
1380
HY-6
双层振荡器
频率:0-200转/分,振幅20mm定时
4800
HY-6A
测速双层振荡器
频率:0-200转/分,振幅20mm定时、速度数显
5180
HY-8
大型调速多用振荡器(摇床)
转速,起动-260rpm/min,工作台尺寸:700×620mm
9880
七、恒温水浴锅、水箱、水槽、低温槽
型号
13800
GPJ-400
人工气候箱
25000
三、DHP电热恒温培养箱
型号
工作室规格(mm)
主要技术参数
出厂价(元)
DHP-200
260×200×300
1.室温+5℃~60℃
2.波动度≤±0.5℃
3.均匀度≤±1℃
4.搁板负荷45kg/m~
2100
DHP-260
260×260×300
2280
DHP-360
34400
YWX-100
盐雾腐蚀试验箱
47300
YWX-160
盐雾腐蚀试验箱
54300
SYW-100
盐雾腐蚀试验箱
湿度范围:85-98%RH
49800
数显恒温振荡器(摇床)

4
79-2
双向磁力加热搅拌器
最大搅拌容量1000ml ,加热功率200W ,调速范围0 ~2400 转/分,正反方向工作
480
5
78HW-1
恒温磁力搅拌器
最大搅ห้องสมุดไป่ตู้容量1000ml ,电子控温,室温~l00℃,加热功率:200W ,调速0~2400转/分
400
6
79HW-1
恒温磁力搅拌器
最大搅拌容量1000ml,电子控温,室温~100℃,加热功率:250W ,调速0~2400转/分
980
15
HJ-4A
数显恒温多头磁力搅拌器
最大搅拌容量4×1000ml ,数显控温室温~100℃,加热4×200W ,调速范围:0 ~2400转/分
2380
16
HJ-5
数显恒温多功能搅拌器
具有电动、磁力双重搅拌功能,数显控温常温~100℃,无级调速
980
l7
HJ-6
多头磁力加热搅拌器
最大搅拌容量6×1000ml ,加热功率:6×200W ,调速范围:0 ~2400 转/分
最大搅拌容量1000ml ,数显控温,室温~100℃,加热功率:300W ,数显测速
980
10
HJ-1
磁力搅拌器
分两种规格,最大搅拌容量500ml , 1000ml ,调速范围:0~2400 转/分
260
11
HJ-2
双头磁力加热搅拌器
最大搅拌容量2×1000ml ,加热功率:2×150W ,调速范围:0~2400 转/分
960
8
HY - 4
往复式调速多用振荡器
工作方式:水平往复,定时范围:0 ~120 分,工作频率:起动~320 次/分
HJ-6 HJ-6A(恒温)磁力搅拌器 使用说明书

HJ-6/HJ-6A(恒温)磁力搅拌器
使用说明书
一:使用说明
HJ-6HJ-6A为六联(恒温)磁力搅拌器,可单独加热、单独使用,也可多联加热,多联使用。
无级调速,操作简便,能在较广的速度范围内对液体溶液进行精密稳定的搅拌,特别适合搅拌小体积的样品,是石油、化工、医药卫生、环保、生化实验室、分析室、教育科研的必备工具。
调速范围:60-2000转/分
数显控温范围:室温~99.9℃(HJ-6A)加热盘直径:12cm
搅拌功率:25W×6加热功率:250W/联
二:使用方法
使用前首先检查随机配件,然后按顺序装好夹具。
打开电源开关,即开始工作,调节调速旋钮至所需转速。
调速是由慢至快,不允许高速启动。
如需加热则打开加热开关,加热指示灯ON亮,然后按下“SET”键,数码管数字开始闪动,此时可以设定温控温度,按“∧”或“∨”键,使数码管显示为所需要的设定温度。
再按“SET”键,回到标准工作模式。
这时仪器已在加热,指示灯开始闪烁,待水温已达到了所设定的温度,指示灯停止闪烁,开始自动恒温。
不工作时应切断电源,加热盘擦拭干净,调速旋钮旋至最低,温控仪调至“0”度。
三:注意事项
1:为确保安全,使用时请接上地线。
2:加热时间一般不宜过长,应间歇使用以延长寿命。
3:中速运转可连续工作8小时,高速运转可连续工作4小时。
金坛市宏华仪器厂
82334280。
HJ-4A数显恒温多头磁力搅拌器

HJ-4A数显恒温多头磁力搅拌器目录一、用途 (2)二、主要技术指标和参数 (2)三、仪器结构 (2)四、仪器使用及注意事项 (3)五、仪器成套及技术文件 (3)本仪器为精密、低温制冷仪器,使用前请详阅说明书,谨慎操作!一、产品简介该产品是实验室工作人员对各种液体进行匀和和搅拌的必备仪器,也是配套各类分析仪器的常规产品。
近二十年的市场销售,被国内外各大院校、环保监测、卫生防疫、石油化工等实验室广泛采用。
本仪器均采用永磁直流电机,具有无噪声、抗振动、力矩大,搅拌效果显著等优点。
二、技术指标★电源电压: 220V+10% 50HZ★电机功率: 4×5W★加热功率: 4×200W★调速范围; 0-1400rpm★定时范围; 0-120min★控温范围(℃):室温—100★控温精度(℃):±1★外形尺寸(长x宽x高cm):48×2l×10One, product introductionThe product is the laboratory staff to various liquid and stirring and the necessary equipment, and supporting various types of analytical instruments in the conventional products.Nearly twenty years of marketing, by domestic and foreign universities, environmental monitoring, health and epidemic prevention, oil and chemical laboratory is widely used.The instrument adopts the permanent magnet DC motor, has no noise, vibration, big torque, stirring effect significant advantages.Two, technical indicatorsIn the power supply voltage:220V+10%50HZMotor power:4 x5W.Heating power:4 x200W.In0-1400rpm speed range;Of0-120min timing range;In the temperature range ( c ) at room temperature: -100On the temperature control accuracy ( c ): + 1Of dimensions ( length x width x high cm ) : 48* 2L * 10。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
HJ-4A数显恒温多头磁力搅拌器
HJ-4A数显恒温多头磁力搅拌器的参数:
HJ-4A
数显恒温多头磁力搅拌器方法:
当使用数显恒温多头磁力搅拌器时,请首先检查随机配件是否齐全,然后按顺序先装好夹具,把所需搅拌的烧杯放在镀铬盘正中,加入溶液把搅拌子放在烧杯溶液中,然后先插上仪器接插的电源插头,再接通电源打开电源调速开关,指示灯亮,即开始工作,调速是由低速逐步调至高速,不允许高速档直接启动,以免搅拌子不同步,引起跳动.温度控制把探头对号插入插座,调置温控旋钮到所需温度即可,不工作时应切断电源,为确保安全,使用时请接上地线.仪器
应保持清洁干燥,严禁溶液进入机内,以免损坏机件,防止剧烈震荡.。