TT22010-T充电模块说明书
艾特顿电源防御模块型号PDG23G0060E2ZN商品说明说明书

Eaton PDG23G0060E2ZNEaton Power Defense molded case circuit breaker, Globally Rated, Frame 2, Three Pole, 60A, 35kA/480V, PXR20 LSI w/ ZSI and Relays, No TerminalsEaton Power Defense molded case circuit breakerPDG23G0060E2ZN 78667920454288.9 mm 152.4 mm 104.6 mm 1.82 kg Eaton Selling Policy 25-000, one (1) year from the date of installation of theProduct or eighteen (18) months from thedate of shipment of the Product,whichever occurs first.RoHS Compliant UL 489CCC MarkedIEC 60947-2CSAProduct NameCatalog Number UPCProduct Length/Depth Product Height Product Width Product Weight WarrantyCompliancesCertifications60 AComplete breaker 2Three-polePD2 Global Class A PXR 20 LSI600 Vac600 VNo Terminals35 kAIC at 480 Vac 10 kAIC Icu @125 Vdc 18 kAIC @600V (UL/CSA)25 kAIC Icu/ 20 kAIC Ics/ 52.5 kAIC Icm @480V Brazil (IEC) 10 kAIC Icu @250 Vdc36 kAIC Icu/ 36 kAIC Ics/ 75.6 kAIC Icm @380-415V (IEC) 20 kAIC Icu/ 15/13 kAIC Ics/ 42 kAIC Icm @525V South Africa (IEC)8 kAIC Icu/ 4 kAIC Ics/ 16.8 kAIC Icm @690V (IEC) 30 kAIC Icu/ 22.5 kAIC Ics/ 63 kAIC Icm @440V (IEC) 35 kAIC @480V (UL)55 kAIC Icu/ 55 kAIC Ics/ 121 kAIC Icm @240V (IEC) 65 kAIC @240V (UL)60 AEaton Power Defense MCCB PDG23G0060E2ZN 3D drawing Amperage Rating Circuit breaker frame type Frame Number of poles Circuit breaker type Class Trip Type Voltage rating Voltage rating - max Terminals Interrupt rating Interrupt rating range Trip rating 3D CAD drawing packageApplication notesPower Xpert Protection Manager x64Consulting application guide - molded case circuit breakersPower Xpert Protection Manager x32BrochuresPower Defense technical selling bookletPower Defense brochurePower Defense molded case circuit breaker selection posterPower Defense molded case circuit breakers - Frame 2 product aid CatalogsPower Xpert Release trip units for Power Defense molded case circuit breakersMolded case circuit breakers catalogCertification reportsEU Declaration of Conformity - Power Defense molded case circuit breakersPDG4 CB reportPDG4 CCC certificationPower Defense Declaration concerning California’s Proposition 65PDG2 CB reportInstallation instructionsPower Defense Frame 2 global terminal shield, 3 pole - IL012330EN Power Defense Frame 2/3/4/5/6 voltage neutral sensor module wiring instructions – IL012316ENPower Defense Frame 2 tunnel terminal (aluminum), 150A, 3 pole instructions - IL012238EN H03Power Defense Frame 2 shunt trip UVR instructions - IL012130EN Power Defense Frame 2 clamp terminal (steel), 20A, 3 pole instructions - IL012246EN H03Power Defense Frame 2 screw terminal_end cap kit, 225A, 3 pole instructions - IL012258EN H01Power Defense Frame 2 Direct Rotary Handle Assy With Interlock Version Instructions (IL012138EN).pdfPower Defense Frame 2 tunnel terminal kits - PDG2X1TA225K instructions- IL012239EN H01Power Defense Frame 2 terminal kit - PDG2X3(2)(4)TA225RF instructions - IL012245EN H01Power Defense Frame 2 tunnel terminal (aluminum), 50A, 3 pole instructions - IL012236EN H03Power Defense Frame 1 IEC and Frame 2 Rotary Mechanism with NFPA Handle Attachment Instructions (IL012260EN).pdfPower Defense Frame 2 terminal kit - PDG2X3(2)(4)TA150RFinstructions - IL012244EN H01Power Defense Frame 2 Bell Alarm Switch Instructions (IL012154EN).pdf Power Defense Frame 2 box terminal (steel), 100A, 3 pole instructions - IL012234EN H03Power Defense Frame 2 tunnel terminal (aluminum), 100A, 3 pole instructions - IL012237EN H03Power Defense Frame 2 box terminal (aluminum), 225A, 3 pole instructions - IL012235EN H03Power Defense Frame 1-2-3-4 IP door barrier assembly instructions -IL012278ENPower Defense Frame 2 locking devices and handle block instructions - IL012149ENPower Defense Frame 2 multi wire connector kit -PDG2X3(2)(4)TA2253W instructions - IL012243EN H01Power Defense Frame 2 handle mech direct rotary handle instructions - IL012134ENPower Defense Frame 2 handle mech variable depth rotary handle instructions - IL012136ENPower Defense Frame 2 multi wire connector kit -PDG2X3(2)(4)TA2256W instructions - IL012242EN H01Power Defense Frame 2 PDG2 and PDC(E)9 breaker instructions -IL012106ENInstallation videosPower Defense Frame 2 Bell Alarm with PXR Animated Instructions.pdf.rh Power Defense Frame 2 withTMTU, Shunt Trip_UVR Animated Instructions.rhPower Defense Frame 2 TMTU Aux, Alarm, ST and UVR Animated Instructions.rhPower Defense Frame 2 Handle Mech Variable Depth Rotary Handle Animated Instructions.rhPower Defense Frame 2 Locking Devices and Handle Block Animated Instructions.pdf.rhMultimediaPower Defense Frame 2 Variable Depth Rotary Handle Mechanism Installation How-To VideoPower Defense Frame 2 Direct Rotary Handle Mechanism Installation How-To VideoPower Defense Frame 3 Variable Depth Rotary Handle Mechanism Installation How-To VideoPower Defense Frame 2 Aux, Alarm, Shunt Trip, and UVR How-To Video Power Defense Frame 5 Trip Unit How-To VideoPower Defense BreakersEaton Corporation plc Eaton House30 Pembroke Road Dublin 4, Ireland © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark.All other trademarks areproperty of their respectiveowners./socialmediaEaton Power Defense for superior arc flash safety Power Defense molded case circuit breakers Power Defense Frame 6 Trip Unit How-To Video Eaton Specification Sheet - PDG23G0060E2ZN Power Defense time current curve Frame 2 - PD2Selling Policy 25-000 - Distribution and Control Products and Services Making a better machineIntelligent circuit protection yields space savingsMolded case and low-voltage power circuit breaker health Single and double break MCCB performance revisited Intelligent power starts with accurate, actionable data Molded case and low-voltage breaker health Safer by design: arc energy reduction techniquesSpecifications and datasheetsTime/current curvesWarranty guidesWhite papers。
MMT-DPW 220DPW10BL 使用说明书

MMT-DPW220DPW10BL使用说明书济南科亚电子科技有限公司在使用本产品前请您详细阅读本使用说明书。
由于不遵守该使用及安装说明书中规定的注意事项,所引起的任何故障和损失均不在厂家的保修范围内,厂家将不承担任何相关责任。
请妥善保管好文件,如有相关疑问,请与厂家联系。
该标志表示一种重要提示或是警告。
安全注意事项·请专业技术人员进行安装、连接、调试该设备。
·在带电情况下不能安装、移除或更换设备线路。
·请务必在本产品的电源输入端与电源之间加装必要的保护装置,以免造成危险事故或致命伤害;需要加装:过流保护器、保险、紧急开关。
·请做好本产品与大地、设备之间的隔离及绝缘保护。
·如确实需要带电调试本产品,请选用绝缘良好的非金属专用螺丝刀或专用调试工具。
·本产品需要安装在通风条件良好的环境中。
·本产品不能直接应用在高湿、粉尘、腐蚀性气体、强烈震动的非正常环境下。
注意!驱动器的控制为不隔离型(BL产品)。
因不隔离的所有外出引线均带有高压电,请在安装、使用时务必要采取绝缘及安全措施,以免造成电击事故。
使用前请仔细阅读本说明书。
目录规格及型号---------------------------------------------------3产品特点-----------------------------------------------------3性能参数-----------------------------------------------------3安装尺寸-----------------------------------------------------4安装要求-----------------------------------------------------4拨码开关设置-------------------------------------------------5驱动器接线端子功能示意图-------------------------------------6控制端子功能介绍---------------------------------------------6外部电位器调节方式及连接-------------------------------------7外部频率输入信号控制方式及连接-------------------------------8频率信号输出-------------------------------------------------9电机接线说明-------------------------------------------------9输入电源说明------------------------------------------------10电位器的功能介绍--------------------------------------------10 LED状态指示说明--------------------------------------------11调试步骤说明------------------------------------------------12联系方式----------------------------------------------------12一、规格与型号最大输出功率最大输出转速输入电压范围型号W rpm AC:(V) 220DPW10BL750W以下电机额定转速90-240二、产品特点:●输入范围宽,可适用于AC110或AC220电源,方便使用。
AC DC 模块电源 FA15-220SXXY2N3 产品说明书

◆宽范围输入:85-305VAC/120-430VDC◆空载功率:≤0.2W◆转换效率:典型87%◆开关频率:65KHz典型◆保护种类:短路、过流、过压保护◆隔离电压:3000VAC◆安全等级:CLASS IIFA15-220SXXY2N3---是爱浦为客户提供的高效率模块电源。
该系列电源具有全球输入电压范围、交直流两用、低纹波,低温升、低功耗、高效率、高可靠性、高安全隔离等优点。
该系列产品在工业、办公电力及民用等多个领域都有重要的应用。
认证型号输出规格最大容性负载(MAX)纹波及噪声20MHz(MAX)效率@满载,220Vac(典型值)功率电压1 电流1 电压2 电流2(W)Vo1(V)Io1(m A)Vo2(V)Io2(m A)u F mVp-p %/ *FA15-220S3V3Y2N3 10 3.3 3000 - - 5000 80(需外围)80 FA15-220S05Y2N3 15 5 3000 - - 5000 80(需外围)82 *FA15-220S09Y2N3 15 9 1667 - - 3000 200 84 FA15-220S12Y2N3 15 12 1250 - - 2000 200 86 FA15-220S15Y2N3 15 15 1000 - - 1000 200 87 FA15-220S24Y2N3 15 24 625 - - 600 240 86注1:因篇幅有限,以上只是部分产品列表,若需列表以外产品,请与本公司销售部联系。
注2:由于测试设备的仪器误差定义最低效率为典型值的-2%。
注3:输出效率典型值是以产品满载老化半小时后为准。
注4:“*”为开发中型号。
注5:纹波及噪声的测试方法采用双绞线测试法,具体测试方法及搭配见后面(纹波&噪声测试说明)即可。
注6:FA15-220S3V3Y2N3,FA15-220S05Y2N3需使用外围电路以降低纹波,具体外围参数见图2项目工作条件最小典型最大单位输入电压范围交流输入85 220 305 VAC直流输入120 300 430 VDC 输入频率范围- 47 50 63 Hz 输入电流115VAC - - 0.3A230VAC - - 0.2浪涌电流115VAC - - 16220VAC - - 30空载功耗输入115VAC -- 0.2 W 输入230VAC -漏电流- 0.5mA TYP/230VAC/50Hz热插拔- 不支持遥控端- 无遥控端项目工作条件最小典型最大单位电压精度输入全电压范围任何负载Vo1 - ±2.0 ±3.0 %Vo2 - - - %线性调节率标称负载Vo1 - - ±0.5 %Vo2 - - - %负载调节率输入标称电压20%~100%负载Vo1 - - ±5.0 %Vo2 - - - %最小负载单路输出0 - - %正负双路共地输出- - -% 正负双路隔离输出- - -启动延迟时间输入220VAC(满载)- 1000 - mS 掉电保持时间输入220VAC(满载)- 100 - mS动态响应25%~50%~25% 50%~75%~50%过冲幅度(%):≤±5.0 % 恢复时间(mS ):≤5.0mS 输出过冲输入全电压范围≤10%Vo%短路保护 可长期短路,自恢复打隔式 漂移系数 - -±0.03%-%/℃ 过流保护输入220VAC ≥130% Io 可自恢复打隔式 过压保护输出3.3VDC ≤7.5 VDC输出5VDC ≤7.5 输出9VDC≤15输出12VDC ≤18 输出15VDC ≤20 输出24VDC≤30项 目工作条件最 小典 型最 大单 位开关频率- 61 65 73 KHz工作温度--40-+75℃需在温度降额曲线的基础上进行温度降额使用,降额曲线图见后面(产品特性曲线)即可储存温度- -40-+85焊接温度波峰焊焊接260±4℃,时间5-10S手工焊接360±8℃,时间4-7S相对湿度 - 10 - 90 %RH 隔离电压 输入-输出测试1分钟,漏电流≤5mA 3000 - - VAC 绝缘电阻 输入-输出@施加DC500V100--MΩ振 动- 10-55Hz,10G,30Min,alongX,Y ,Z 平均无故障时间(MTBF )-MIL-HDBK-217F@25℃>300,000HEMC 特性EMI传导骚扰CISPR22/EN55022,CLASS B (推荐电路见图1) 辐射骚扰CISPR22/EN55022,CLASS B (推荐电路见图1) EMC 静电放电IEC/EN61000-4-2 ±6KV/8KV Perf.Criteria B辐射抗扰度IEC/EN61000-4-3 10V/m Perf.Criteria A脉冲群抗扰度IEC/EN61000-4-4 ±1KV Perf.Criteria BIEC/EN61000-4-4 ±2KV(推荐电路见图1) Perf.Criteria B浪涌抗扰度IEC/EN61000-4-5 ±1KV Perf.Criteria BIEC/EN61000-4-5 ±2KV (推荐电路见图1) Perf.Criteria B传导骚扰抗扰度IEC/EN61000-4-6 10Vr.m.s Perf.Criteria A工频磁场抗扰度IEC/EN61000-4-8 10A/m Perf.Criteria A 电压暂降、跌落和短时中断抗扰度IEC/EN61000-4-11 0%-70% Perf.Criteria B封装代号L x W x HY2 50.8X25.4X15.6 mm 2.000X1.000X0.597inch管脚说明1 2 3 4 AC(N)AC(L)+Vo -Vo 输入零线输入火线输出正极输出负极注意:电源模块的各管脚定义如与选型手册不符,应以实物标签上的标注为准。
10 埠智慧型 USB Type-C 充電系統 使用者手冊说明书

使用者手冊10埠智慧型USB Type-C充電系統Copyright©2017 KING-ON 目錄1.產品介紹 (1)2.安全訊息 (1)3.安裝說明 (2)4.面板訊息 (3)5.基本操作 (4)6.規格 (5)7.技術支援 (6)8.充電車故障排除 (7)1.產品介紹多埠智慧型USB Type-C充電系統,是一款為可攜式電腦型設備提供電池充電和管理的系統。
可從公司或學校等大型組織的公用網絡上監控管理多個可攜式電腦型設備(筆記電腦/Chromebook/平板電腦)被充電的設備狀態。
在無此系統之前,這些智慧型設備必須單獨地連接到插座上,十分占據空間且較難整理! 然而,有了多埠智慧型USB TYPE-C 充電系統,您可以輕鬆地為這些設備的電池充電,並有效地管理系統設備,大幅度節省人力成本。
每個多埠智慧型USB TYPE-C充電系統 SCMF10可以同時充電10個可攜式電腦型設備。
您也可以將2個或3個多埠智慧型USB TYPE-C充電系統串接為一組,使您可以同時管理多達30台可攜式電腦型設備,而根據您需要管理的數量不同,您可以自行選擇如何搭配可容納10個的系統設為一組,達成管理10/20/30台可攜式電腦型設備的目的。
智慧型USB TYPE-C充電系統 SCMF10提供了一個節省空間和安全充電的方法。
對於同種單一系列的可攜式電腦型設備,設備的電池充電可以有效的完成,使企業或商業管理可攜式電腦型設備更加輕鬆、簡單。
2.安全訊息在使用我們的產品之前,請仔細閱讀、理解並遵守本指南中的所有安全訊息。
✧ 2.1 室內使用本產品適用於室內使用,請插入100~240VAC,50/60Hz的電源插座。
任何不當使用都可能會損壞產品和/或造成不安全的運作條件。
✧ 2.2 使用地點♦選擇氣流方向不受阻礙的位置。
♦將產品放在平坦的水平表面上,並離任何熱源(如暖爐)至少60公分遠。
♦將產品遠離任何液體。
✧ 2.3 電氣♦將產品插入接地、極化的電源插座。
直流电力电源充电模块ER22010TN含义

一、ER22010TN直流电力电源充电模块称说明概述
ER22010TN直流电力电源充电模块称可在工作电流范围内进行频繁的操作或多次开断短路电流;机械寿命可高达30,000次,满容量短路电流开断次数可达50次。
直流电力电源充电模块适于重合闸操作并有极高的操作可靠性与使用寿命。
直流电力电源充电模块(普通型)采用了立式的绝缘筒防御各种气候的影响;且在维护和保养方面,通常仅需对操作机构做间或性的清扫或润滑。
直流电力电源充电模块(极柱型)采用了固体绝缘结构—集成固封极柱,实现了免维护。
直流电力电源充电模块在开关柜内的安装形式既可以是固定式,也可以是可抽出式的,还可安装于框架上使用
动静触头允许磨损累计厚度mm 3
四、直流电力电源充电模块选型
用户可根据被保护对象选用不同型号的直流电力电源充电模块,对使用场所的不同可选用防污型和高原型。
为满足市场的需求我厂可根据用户的要求设计各种非标产品。
《直流电力电源充电模块ER22010TN》
五、直流电力电源充电模块使用条件:
1.适用于户内、外;
2.环境温度-40℃~+40℃;
3.海拔高度不超过3000m(瓷套式不超过1000m);
4.电源频率不小于48Hz、不超过62 Hz;
5.长期施加在直流电力电源充电模块端子间的工频电压不超过直流电力电源充电模块的持续运行电压;
6.地震烈度8度及以下地区;
7.大风速不超过35m/s。
8.直流电力电源充电模块保护发电厂、变电站的交流电气设备免受大气过电压和操作电压的损坏。
直流电。
消防电源模块说明书

TH220X03Z-220AC消防电源模块技术说明书XXXXXXXX公司拟制:审核:批准:目录第一章概述-------------------------------------------------- 2一、前言-------------------------------------------------- 2二、模块主要特点-------------------------------------------- 2三、模块保护功能-------------------------------------------- 2四、技术指标-------------------------------------------- 4五、型号命名-------------------------------------------- 4第二章模块构成---------------------------------------------- 5一、模块工作原理-------------------------------------------- 5二、模块外形尺寸及固定孔尺寸---------------------------- 5三、接线说明------------------------------------------------ 7四、立式卧式效果图------------------------------------------ 7 第三章使用环境---------------------------------------------- 8第一章概述一、前言我公司研制开发的TH系列电源模块,采用世界领先的“谐振电压型双环控制的谐振开关电源技术”,具有体积小、重量轻、效率高、高可靠等优点。
二、模块主要特点●可适用于交流220V输入方式。
●效率高,模块效率超过92%。
●重量轻,体积小。
高隔离电压DC DC IGBT驱动电源1X-PD220产品手册

BEIJI NG L MY ELECTRO NICS CO.,LTD TX-PD220高隔离电压DC/DCIGBT驱动电源TX-PD220产品手册BEIJI NG L MY ELECTRO NICS CO.,LTD TX-PD220目录一、概述 (3)二、电气参数 (3)2.1 极限参数 (3)2.2 电性能参数 (3)2.3 工作条件 (4)三、尺寸结构 (4)3.1 外形尺寸 (4)3.2 引脚说明 (4)四、应用电路说明 (5)4.1 典型应用电路 (5)4.2 说明 (5)4.3 可定制参数 (5)五、相关产品信息 (6)5.1 TX- KA105特大功率IGBT驱动器 (6)5.2 TX- PD203(DC-DC模块电源) (6)5.3 TX-PA202 (AC/DC电源) (6)六、常见问题 (6)七、其它说明 (6)BEIJI NG L MY ELECTRO NICS CO.,LTDTX-PD220TX-PD220 高隔离电压 DC/DC 驱动电源一、概述∙ 专为高压变频器等需要高隔离电源而设计,DC/DC 变换,两路隔离输出。
∙ 初次级隔离电压15KV/AC ,次级2路输出隔离电压10KV/AC 。
∙ 输入输出耦合电容小。
∙ 输入电源过压、欠压保护。
∙ 输入电源极性保护。
∙输出电压、工作环境温度等参数可定制。
二、电气参数 2.1 极限参数2.2 电性能参数除另有指定外,均为在以下条件时测得:Ta=25℃,Vi=15Vdc,双路负载均RL=240ΩBEIJI NG L MY ELECTRO NICS CO.,LTDTX-PD2202.3 工作条件三、尺寸结构 3.1 外形尺寸3.2 引脚说明BEIJI NG L MY ELECTRO NICS CO.,LTDTX-PD220四、应用电路说明 4.1 典型应用电路4.2 说明∙ 本电源因绝缘电压较高,因此没有电压反馈,故而需要比较稳定的直流输入。
深圳市思特克电子技术 SET220 24-500 1000W 直流电源技术手册

SET220/24-500/1000W直流电源技术手册深圳市思特克电子技术开发有限公司地址:深圳市南山区西丽镇大磡思特克工业园199号联系电话:*************26527304 26527137传真:************* E-mail:*************.cn目录一、SET220/24-500/1000W直流电源概述 (3)二、SET220/24-500/1000W型号说明 (4)三、SET220/24-5OO/1000W功能简介 (5)四、SET220/24-500/1000W技术参数 (6)五、SET220/24-500/1000W机器结构特征 (8)六、使用方法 (9)七、注意事项 (9)八、附件 (9)质量保证卡 (10)警告:不要拆卸电源系统上的任何外壳或模块。
设备内部零件带有致命性的电压或存有高能量的危险!SET220/24-500/1000W直流电源技术手册资料版本SETEC-POWER-DC/DC REV1.1深圳市思特克电子技术开发有限公司主要生产、经营通信用高频开关电源、逆变电源和其它系列电源系统。
公司研发生产的思特克电源,其技术先进、品质优秀。
公司的客户主要是国内信息产业界的大型电信运营商、电力系统、广电系统、以及相关的配套设备生产商。
公司既能为大型电信运营商提供高频开关电源设备,又能为相关生产商提供配套电源。
公司致力于在民族产业之林中独树一帜,吸收世界知名企业的先进技术及其管理经验,建立自己的高科技企业,为发展自主的民族产业而努力。
思特克公司的产品能满足电力系统、通信系统对电源的广泛需求。
既能满足低容量要求的场合、小模块局、接入网、光线传输中断站等,又能满足高电源容量的要求,如移动基站、微波通信、中心局等。
公司的宗旨是,用户需要第一、产品质量一流、售后服务周到。
并已通过了ISO90 00-2000质量体系认证,随着世界科技事业的迅猛发展,我国以信息产业和以其为龙头而拉动的其它行业也在日新月异地发生变化,隐藏着巨大的商机和经济效益。
- 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
- 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
- 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。
第1页共11页整流模块简介
TT系列电力专用高频开关整流模块采用先进的谐振式软开关技术;专门针对各类变电站、电厂及其他直流供电场合的直流屏而设计。
TT系列整流模块采用智能风冷的散热方式,具有高效率,高密度,高功率因数、高可靠性等特点,同时具有造型美观、占用空间少;采用2U*4U标准设计,内置防倒灌二极管,方便客户组屏。
TT系列总包括4款型号:TT11010-T/TT22005-T/TT11020-T/TT22010-T; 4款整流模块采用统一外观,统机箱,统一开孔尺寸,方便客户选型设计。
整流模块型号说明见下图:
TT22010-T整理模块型号说明
工作原理:
整流模块工作原理图如下所示:
第2页共11页
外观及接口
1.整流模块外观
TT22010-T整流模块外观
2.前面板
LE 口播空
数隍
微训庭钮一睫马幵关
产品型号
TT22010-T整流模块前面板
1) LED指示灯
(红色)
故障指 示
灯
灭
亮
输出欠压保护E36 风
扇故障E37 (具体信心参见 故障代码)
2) 数码管
可显示模块电压、电流、地址、告警等信息。
若按键无操作超过大约 30秒后,将自动显示模块电
压,此时如果存在告警,则显示故障代码。
电压显示精度为土
IV ,电流显示精度为土 0.1A 。
3) 微调旋钮
由于不同用户现在蓄电池的节数有差异, 可以通过拨码开关设置整流模块为手动调压时,
整流模块
输出电压自动调整到出厂设定值 235V (标称220V 模块)或121V (标称110V 模块),为了安全起见,
非专业人员请勿操作。
4) 显示按钮
默认为显示电压,按下时依次显示输出电压、输出电流、模块地址。
5) 拨码开关设置
拨码开关用于设置整流模块的控制方式、模块组号、模块地址, 址设置请参照下表:
OFF
1号为最低位,4号为最高位。
模块地 6
1
模块地址 (0~15) 模块组号(1~2)
控制模式(ON:手动、OFF:自动)
二进制与十进制对应关系表
拨码设置说明:
整流模块地址通过拨码开关1234号位设置地址,可设置范围为0~15,亦即每组整流模块的最大并机数为
15个。
通过拨码开关第5号位设置模块分组号,可设置范围1~2组。
整流模块只在相同分组号组内进行均流,
组间不均流。
不同整流模块S485总线可以串联到主监控单元的同一组S485接口,实现一个主监控单元对多个整流模
块组的控制管理。
整流模块地址是监控单元识别个整流模块的唯一标志,同一电源系统中整流模块的地
址设置(分组号+模块地址)不能相同。
对于同一个整流模块通信地址设置必须与监控单元中的整流模块地址设置相同,否则异常。
通过拨码开关的第6号位设置手动控制和自动控制(ON:手动、OFF自动);在自动控制方式下,整流模块的输出电压、限流点、开关机均由监控单元进行控制,人工无法进行干预。
如果整流模块连接到合闸母线上对电池进行充电,一般应设置为自动控制方式。
在手动控制方式下,整流模块的输出电压、限流点、开关机均不接受监控单元控制,但可以将整流模块
的运行参数上报给监控单元。
如果整流模块连接到控制母线上,则整流模块只输出单一的稳定电压,限
流点全部放开,为110%。
手动控制方式下的整流模块与自动控制方式下的整流模块之间不均流。
3.接口定义
参数指标
注:海拔超过2000m需要降额使用,降低工作环境温度1° C/100m.
绝缘电阻与绝缘强度
1、绝缘电阻
输入端、输出端对外壳之间以及输入对输出之前的绝缘电阻〉2M Qo
2、绝缘强度
输入端、输出端段节后,在输入/输出端与外壳之间施加2000V交流电压1分钟,无击穿或飞弧现象。
四、其他功能
1. 保护功能
整流模块具有以下保护功能:输入过/欠压保护,输出过/欠压保护,输出欠压告警、短路保护、缺
相保护、过温保护和风扇故障告警。
整流模块保护/告警信息以故障代码形式在LED上实时显示, 故障代码如下:
2. 通信功能
整流模块内置ENPC和MODUS两种通信协议,可自动识别。
整流模块通过S485方式与监控单元通信,将整流模块输出电压和电流,整流模块保护和告警信息发送给监控单元。
在自动方式下,接受并执行监控单元下发的控制命令。
在手动方式下,整流模块不接受监控单元的控制。
具体通信功能见下表。
五、安装设计
整流模块机械参数
整流模块外形尺寸(长*宽*高):325 X 88x 178mm
单模块托架参数
页
i
*
s
ft ■
T*甲
_ __nt 葩
如果采用天英公司提供托架固定(请按照固定孔位开$ 5通孔即可,面板本身不需压铆),安装流程如下第二步将托架固定在两根横梁上,如图所示:
1血牙® •佗「• !
模块托架固定横梁图
第11页共11
页
1、整流模块采用智能风冷散热方式,风扇安装于模块前部,从整流模块前方抽风吹向模块后方。
因此在安排模块位置时,应保证模块前后散热风道的畅通;建议整流模块之前间隔15~20cm。
同时,整流模块后方尽
量少安装敏感部件,设计是尽量避免直流传感器、温度传感器、采样单元盒等器件安装到风道附近。
2、模块具备热插拔功能,但禁止在易燃环境中对模块进行热插拔;模块不应直接连接到系统交流母线上;为了方便模块的单个维护,模块交流输入进线处应分别设置单独的空气开关。
3、电缆可以选择非屏蔽电缆,根据实际情况选取适当长度的电缆。
为方便使用,我司可提供模块的配套插框,供客户选购。
六、包装、运输与故障处理
产品包装
本产品外包装采用专用纸箱,内包装采用防震材料进行包装,不可回收!
运输
本产品因在包装完好的情况进行运输,严禁在运输过程中存在剧烈震动和撞击;同时防止受潮,雨淋。
温馨提示:因整流模块在系统上只靠面板上M4螺钉固定以防止整流模块滑落,没有与机柜紧固连接。
直流屏机柜在运输时,请务必将整流模块取下,单独包装运输,严禁将整流模块安装于直流屏机柜上运输,否则将造成系统机柜和整流模块损坏。
故障处理
注意:
未经许可,严禁擅自打开整流模块外壳。
否则,由此造成的设备损坏及人身伤害天英公司概不负责; 同时,由此造成的技术泄密,天英公司保留追究相关法律责任的权利
模块常见故障表现有:电源指示灯(绿色)灭、保护指示灯(黄色)亮、故障指示灯(红色)亮。
同时数码管显示故障代码。
常见故障代码及处理如下:
第12页共11
页
安全注意事项
在开始操作之前,请仔细阅读操作指示、注意事项,以减少意外的发生。
产品及产品手册中的“小 心、注意、警告、危险”事项,并不代表所应遵守的所有安全事项,只作为各种操作安全注意事项 的补充。
因此,负责天英公司产品安装、操作的人员必须经严格培训,掌握系统正确的操作方法及 各种安全注意事项后方可进行设备的各项操作。
在进行本公司产品、设备的各项操作时,必须遵守相关行业的安全规范,严格遵守由天英公司提供 的相关设备注意事项和特殊安全指示。
咼压
交流电源设备的安装,必须遵守相关行业的安全规范,进行交流设备安装的人员,必须具有高压、 交流电等作业资格。
操作时严禁在手腕上佩带手表、手链、手镯、戒指等易导电物体。
发现机柜有水或潮湿时,请立刻关闭电源。
在潮湿的环境下操作时,应严格防止水分进入设备。
安装过程中不能容许
操作的开关和按扭上,必须挂上禁止标识牌。
电池
电池的不规范操作会造成危险。
操作中必须严格注意、小心防范电池短路或电解液溢出、流失。
电 解液的溢出会对设备构成潜在性的威胁,会腐蚀金属物体及电路板,造成设备损坏及电路板短路。
电池安装、操作前,为确保安全,应注意如下事项:
摘下手腕上的手表、手链、手镯、戒指等含有金属的物体。
使用专用绝缘工具。
使用眼睛保护装置,并做好预防措施。
使用橡胶手套,佩戴好预防电解液溢出的围裙。
电池在搬运过程中应始终保持电极正面向上,严禁倒置、倾斜。
危险。