1U 2U电源控制器说明书

合集下载

nVent ERICO PlusCU 2L 6V 电源控制器操作指南说明书

nVent ERICO PlusCU 2L 6V 电源控制器操作指南说明书

C o u n t -u p I g n i t i o n I n d i c a t o rT r i g g e r G u a r dT r i g g e rB a t t e r y D o o rB a t t e r y I n d i c a t o rC a d w e l d P l u s C u p C o n n e c t o rP L U S C U 2L 6P L U S C U 2L 15P L U S C U 2L 6N B P B P L U S C U 2L 6P B P L U S C U 2L 15P L U S C U 2R L D 6P L U S C U 2R L D 15L e a d C o n n e c t o rIndicator lights are flashing:The PlusCU uses an internal charging mechanism that sends an electric current to the Cadweld Plus cup. If the trigger on the control unit is pulled before the internal charging mechanism resets, the lights will flash. Wait 5 seconds and try again.If the error message persists, contact your nVent ERICO representative.PlusCU does not respond when trigger is pulled:If the unit does not respond, check battery status to determine if new batteries are needed.Cadweld Plus cup does not ignite:Disconnect the PlusCU lead from the PlusCU then re-examine your mold, weldmetal cup, ignition strip, and other Cadweld equipment to verify proper setup.If this issue persists, contact your nVent ERICO representative.PlusCU does not function properly at temperatures below 0° F [-18°C]:Alkaline batteries are not intended for extreme cold temperatures. nVent ERICOrecommends the use of lithium-ion batteries at temperatures below 0° F [-18°C].WARNING:nVent products shall be installed and used only as indicated in nVent product instruction sheets and training materials. Instruction sheets are available at and from your nVent customer service representative. nVent products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.2.All instructions must be completely followed to ensure proper and safe installation and performance.3.Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property4.damage, serious bodily injury and/or death, and void your warranty.SAFETY INSTRUCTIONS:All governing codes and regulations and those required by the job site must be observed.Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.nVent, nVent CADDY, nVent ERICO Cadweld, nVent ERICO Critec, nVent ERICO, nVent ERIFLEX, and nVent LENTON are owned byHigh voltage electrical shock hazard. Keep hands and body clear of the cord(leads) while operating. Failure to do so can result in death or serious injury.Safety First!Personal SafetyWhen working with nVent ERICO Cadweld Plus, always use appropriate safety equipment suchas eye protection, heat-resistant gloves, and other PPE as appropriate to the application and required by local safety codes.Avoid contact with hot materials. Maintain safe working distance and secure footing whilewelding or working with hot materials.Welding material is a mixture of oxides and metal which react to produce hot molten materialwith temperatures in excess of 1400° C [2500° F] and a localized release of smoke. Thesereactions are not explosive and not known to be toxic. Ignition temperatures of weldingmaterial are in excess of 900° C [1650° F] and will not ignite under ambient conditions.For reduced or eliminated smoke options, contact nVent ERICO.。

IUP系列智能直流电源说明书

IUP系列智能直流电源说明书
5为出线柜每一台开关柜内独立配置iupiupiupiup系列智能微型直流操作电源系列智能微型直流操作电源系列智能微型直流操作电源系列智能微型直流操作电源ivtsysivtsysivtsysivtsys英微特电源英微特电源英微特电源英微特电源2g1g1g1g1控控控控制制制制回回回回路路路路路路路路路路路路路路路路g3g3g3g3控控控控制制制制回回回回回回回回回回回回储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线储能小母线g4g4g4g4控控控控制制制制制制制制信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线信号小母线g5g5g5g5控控控控无直流屏4台开关柜1进3出无直流屏4台开关柜1进3出无直流屏4台开关柜1进3出无直流屏4台开关柜1进3出ac220vac220vac220vac220viup200iup200iup200iup200llllnnnndcdcdcdcdcdcdcdcdc220vdc220vdc220vdc220v控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线控制小母线如上图所示g可以为四台开关柜的一次和二次设备提供直流操作电源
在停电较长时间后或首次使用时,接上交流输入,开启开关,需连续充电 10 小时以上,以免要合分闸操作时,电池无法提供足够的功率。
■ 保护功能
5
IUP 系列智能微型直流操作电源
ivtsys 英微特电源
◆ 输出过压保护 直流输出有过压保护功能,当电压大于 231V,自动关闭输出,红色“关闭输

1u开关整流器用户手册V1

1u开关整流器用户手册V1

15A 描述
第 1 章 概述
20A 描述
符合 EN60950 的要求
电池充电电流大于 0.6A,整流器将进入均充,均充电压为 56.4V,当充电 电流大于 3.5A 时,整流器进入限流均充状态,当电池充电电流小于 0.6A 时,整流器将自动转为浮充状态,浮充电压为 53.5V。(24V 时电压减半) 交流断电时,接入电池,如电池电压大于 42.5V,此时整流器内的电池继 电器吸合,电池在线可对负载放电,若电池电压低于 42V,整流器将断掉 电池进行保护。(24V 时电压减半) 整流器不开机时,接入电池,即使电池反接整流器开机也也不会烧毁。如 果整流器在开机状态下接入电池,如电池反接,将会烧毁,严禁开机接入 电池。 平均故障间隔时间 MTBF≥100 000 h 强迫风冷的冷却方式(整流器内部有直流风扇,风通量为 10 CFM)。
第 4 章 使用和维护 4.1 使用………...………………………………………….……………….……..………..10
4.1.1 整流器使用………………………….………………….....................................10 4.1.2 内部保护功能……………………………….…………………...……………..10 4.2 维护………...………………………………………….…………………………….....11 4.2.1 日常维护………...………………………………………….…………………..11 4.2.2 故障处理………...………………………………………….…………………..11
­15°C ~+50°C ­40°C ~+85°C 10%~90%(无凝露) 高×宽×深:45 mm×282 mm×242 mm(不计输出端子) 3.5 kg YD/T731­2002 通信用高频开关整流器

汇川H1u(2u)PLC数字量扩展模块随机手册

汇川H1u(2u)PLC数字量扩展模块随机手册
X07 X11 X13 X15 X17 X00 X02 X04 X06 X10 X12 X14 X16 H2U-1600ENDR
注意
·
♦ 空端子
,不要外部配线; 图二 产品构造图

表五:电气规格
项 目 普通输入端 漏型/源型方式。当S/S端子与24V短接时为漏型输入;当S/S端子与COM短接 时为源型输入。 检测电压 电气参数 输入阻抗 输入为ON 输入为OFF 数字滤波 滤波功能 硬件滤波 只有一个公共端,为S/S DC24V 3.3k~4.3k 3.5mA Min 1.5mA Max 无 除X0~X7以外的其余IO端口为硬件滤 波,滤波时间约10ms
COM
■ 接线端子定义
1) H2U-1600ENN/ H2U-1600ENDR
H1U - - - √ √ √
2 1 3
4 5
6 7
8 9
10 11
12 13
14 15
16 17
18 19
20
S/S X01 X03 X05 X07 X11 X13 X15 X17 X00 X02 X04 X06 X10 X12 X14 X16 H2U-1600ENN
注意
♦ 装卸扩展模块时,请务必切断电源; ♦ 产品废弃时,请按工业废弃物处理。
加速度谱 密度
CanBus通信口
1 2 3 4 5
䃻䃻H1U/䃻H2U系列扩展模块的主要特点:
* * * * 支持点数。最多同时支持8个本地模块和62个远程扩展模块。 访问方便。远程扩展模块通过FROM/TO指令访问,BFM区定义与本地扩展模块的 定义相同。 布线灵活。远程扩展模块(500Kbps:2个站/70米;63个站/25米。仅供参考)。 量程丰富。支持-10000~+10000、-2000~+2000、0~+2000等量程。

一达达2U电源面板指南说明书

一达达2U电源面板指南说明书

1.0 PurposeThis document defines instructions for using 2U Power Patch Panel P/N 81000569.2.0 Environmental ConditionsThis product is designed for indoor use. Temperature 0 to +40C.3.0 Power Input56 & 12 VDC are supplied to the panel using accessory power supply modules,the power supply input is 100-240VAC, 50/60Hz, 5A4.0 DC Power Output(6x) 3 position terminal blocks (return, +56V and +12V) and (6x) 2 position terminal blocks(return, +56V).Power available at the rear terminal blocks are as follows:With 1 Power Supply – 80 watts maximum at 56V to a total maximum of 250W and 10 wattsmaximum at 12V to a maximum of 60w for the whole panel.With 2 Power Supplies – 80 watts maximum at 56V to a total maximum of 500W and 10watts maximum at 12V to a maximum of 60w for the whole panel.5.0 UseThis product is compatible with power supply modules and media conversion modules,which slide gently into slots in an unpowered panel. The output terminal blocks supplypower to class 2 circuits.6.0 Warnings6.1 There is a risk of shock on output terminals 50<voltage<56VDC.6.2 This panel is meant to be installed in a dry indoor location with controlled access byappropriate trained technicians.6.3 Some accessory modules include Class 1 Laser components.6.4 High touch current when multiple power supply modules are installed requires groundconnection before connecting supply. The building installation shall provide a means forconnection to protective ground and the panels shall be connected to it via the socketterminal or any of the three ground studs on the rear output panels. A service person shallcheck whether or not the socket outlet from which the power supplies are powered providesa connection to the building protective ground. If not, the service person shall arrange for theinstallation of a protective grounding conductor from any of the ground studs to theprotective ground wire in the building.6.5 Symbols placed on the equipment:Symbol ExplanationATTENTION, CONSULT ACCOMPANYINGDOCUMENTSRISK OF SHOCKPROTECTIVE GROUND6.6 This product is intended to be used in a location having equipotential bonding such as atelecommunication center, a dedicated computer room, or a restricted access location.6.7 Installation:6.7.1 The building installation shall provide a means for connection to protectiveground.6.7.2 The equipment is to be connected to that means6.7.3 Service person shall check whether or not the socket-outlet from which theequipment is to be powered provides a connection to the building protectiveground. If not, the service person shall arrange for the installation of a protectivegrounding conductor from the separate protective grounding terminal to theprotective ground wire in the building.6.8 The chassis is equipped with a grounding stud on each terminal bay. This stud comes with astar lock washer and a nut. As power supplies are installed into each bay, the serviceperson must connect the grounding stud on the chassis terminal bay to the grounding stud on the rear of the power supply.6.9 The grounding conductor between the chassis terminal bay and power supply shall besecured to the chassis with the provided grounding stud, star lock washer and nut. Then the protective grounding conductor from the chassis grounding stud to protective ground wire in the building shall be secured to the same stud, using the supplied lock washer and nut and ensuring the nut engages at least 2 complete threads.6.10 IllustrationsDimensionsInches [mm]Oblique viewsRear Terminal Block Connections。

H1U H2U 系列可编程控制器 指令及编程手册

H1U H2U 系列可编程控制器 指令及编程手册

前 言H1U/H2U系列PLC是深圳市汇川控制技术有限公司研发的高性价比控制产品,指令丰富,高速信号处理能力强,运算速度快,允许的用户程序容量H2U可达24K步(H1U可达12k步),且不需外扩存储设备。

控制器配备了四个通讯硬件端口,方便现场接线;通讯端口支持多种通讯协议,包括MODBUS主站、从站协议,尤其方便了与变频器等设备的联机控制;提供了严密的用户程序保密功能,子程序单独加密功能,方便用户特有控制工艺的知识产权保护。

控制器提供了多种编程语言,用户可选用梯形图、指令表、步进梯形图、SFC顺序功能图等编程方法。

指令系统为广大工程技术人员所熟悉,而本公司提供的AutoShop编程环境,更是融合了众多PLC编程环境的优点,丰富的在线帮助信息,使得编程时无需查找说明资料,方便易用。

对高速输出信号的处理部分,H1U系列标配3路高速输出,H2U系列部分MT型号为具有三路高速输出功能,MTQ版本则提供了六路高速脉冲输入、五路高速脉冲输出功能,处理能力增强。

本《H1U/H2U系列可编程控制器指令及编程手册》的知识产权属于深圳市汇川控制技术有限公司所有,我公司会根据情况不断更新升级,恕不另行通知,欢迎用户读者随时访问我公司网站,下载最新版本的手册与资料。

我们热忱欢迎读者以多种形式咨询和交流使用方法,反馈手册中的错误和遗漏。

公司网页:信息交流:plc@12目 录前言 (1)手册版本信息 (8)指令详解索引 (9)简单逻辑指令 (9)应用指令(以FNC NO为序) (9)应用指令(以指令助记符为序,未含简单逻辑指令) (11)手册快查引导 (13)第一章 梯形图及梯形图程序 ����������������������������161.1 梯形图的编程特点 (16)1.2 梯形图编程时使用的元件符号 (16)1.3 PLC的执行原理 (17)1.4 PLC数值的基本知识 (18)第二章 H1U/H2U 系列PLC的使用方法 �������������������������242.1 使用PLC的软件硬件需求 (24)2.2 编程与用户程序下载 (24)2.3 与HMI的配合使用 (24)第三章 软元件说明 ��������������������������������263.1 输入继电器X (26)3.2 输出继电器Y (26)3.3 辅助继电器M (27)3.4 状态继电器S (28)3.5 计时器T (28)3.6 计数器C (29)3.7 寄存器D (33)3.8 子程序与中断指针P、I (34)3.9 常数K、H (36)3.10 控制器软元件规格 (37)第四章 指 令 ����������������������������������404.1 基本指令 (40)4.2 步进顺控指令 (44)4.2.1 STL编程指令 (44)4.2.2 SFC顺序功能图编程 (46)4.2.3 SFC编程实例 (51)4.3 应用指令 (60)4.3.1 程序流程(00~09) (62)4.3.2 传送与比较(10~19) (71)4.3.3 四则逻辑运算(20~29) (81)4.3.4 循环移位(30~39) (91)4.3.5 数据处理(40~49) (98)4.3.6 高速处理(50~59) (108)4.3.7 方便指令(60~69) (124)4.3.8 外围设备I/O(70~79) (136)4.3.9 外围SER设备(80~93) (147)4.3.10 浮点数(110~147) (164)4.3.11 定位控制(150~159) (190)4.3.12 时钟运算(160~169) (203)4.3.13 外围设备(170~177) (210)4.3.14 接点比较(224~246) (213)第五章 通信功能 ���������������������������������2185.1 概要 (218)5.1.1 硬件及通信连线 (218)5.1.2 H2U通信协议切换逻辑说明 (219)5.2 HMI监控协议 (223)5.3 并联协议(1:1) (223)5.4 N:N协议 (225)5.5 计算机链接协议 (227)5.6 MODBUS协议说明 (234)5.6.1 MODBUS主站通讯应用 (235)5.6.2 MODBUS从站通讯应用 (238)5.6.3 多台PLC之间采用MODBUS协议通讯的编程方法 (242)5.7 PLC与MD320系列变频器的通讯编程方法 (244)5.7.1 MD320配合PLC应用的功能码设置 (244)5.7.2 PLC修改MD320功能码的编程 (249)5.8 CAN通讯指令说明 (251)5.8.1 硬件配置 (251)5.8.2 CAN通信相关变量 (252)5.8.3 FROM/TO指令 (255)5.8.4 CANTX/CANRX指令 (255)5.9 PLC无线远程监控 (258)5.9.1 简述 (258)5.9.2 设备及软件需求 (258)5.9.3 无线通信模块设定 (258)5.9.4 通信连接 (259)第六章 扩展模块及扩展卡的使用方法 ������������������������2646.1 扩展模块概要 (264)6.1.1 命名规则 (264)6.1.2 基本型号 (264)6.1.3 H2U-CAN-BD扩展卡 (265)6.1.4 扩展模块地址编号 (265)6.1.5 模块的安装尺寸及用户接口表 (266)6.2 数字量输入/输出扩展模块 (267)6.2.1 数字量输入扩展模块 (267)6.2.2 数字量输出扩展模块 (268)6.3 模拟量输入模块 (269)6.4 模拟量输出模块 (274)6.5 模拟量混合(输入/输出)模块 (278)6.5.1 H2U-4AM(R)2通道模拟电压电流输入/2通道模拟电压电流输出混合扩展模块 (278)6.5.2 H2U-6AM(R)4通道模拟电流输入/2通道模拟电压电流输出混合扩展模块 (284)6.5.3 H2U-6CM(R)4通道模拟电压输入/2通道模拟电压电流输出混合扩展模块 (290)6.6 温度控制模块 (297)6.7 扩展卡使用说明 (305)6.7.1 H2U系列6A/6B扩展卡使用说明 (305)6.7.2 H1U/ H 2U系列通讯扩展卡使用说明 (307)第七章 附 录 ����������������������������������3107.1系统特殊软元件 (310)7.1.1 H1U&H2U通用的系统特殊软元件 (310)7.1.2 H2U-XXXX MRN/MTN系列的系统特殊软元件 (316)7.1.3 H1U/H2U-XXXX MR/MT-XP系列新增加的系统特殊软元件 (317)7.2 出错信息说明 (319)7.3 错误代码存贮 (322)7.4 H2U系列MTQ型与MT型的软件差别 (322)7.5 H2U系列高速处理指令的增强功能说明 (324)7.6 程序流程控制指令的相互关系 (328)7.7 部分特殊继电器和寄存器功能说明 (330)附表:产品型号订货索引 (345)第一章 梯形图及梯形图程序1第五章 通信功能5第三章 软元件说明3第七章 附录7第二章 H1U/H2U系列PLC的使用方法2第六章 扩展模块及扩展卡的使用方法6第四章 指令4手册版本信息89指令详解索引简单逻辑指令应用指令(以FNC NO为序)10应用指令(以指令助记符为序,未含简单逻辑指令)1112手册快查引导您若有如下疑问,可参照指引:13141 梯形图及梯形图程序16第一章 梯形图及梯形图程序1.1 梯形图的编程特点:PLC 中梯形图编程方法是仿传统继电器控制系统的电气原理设计的一种设计方法,设计中使用的元件如按钮开关X 、中间继电器M 、时间继电器T 、计数器C 、触点等,都和实际的电气元件的特性相似。

机架式稳压电源 PS-DC1212-1U 说明书

机架式稳压电源 PS-DC1212-1U 说明书

POWER SUPPLY (1RU )
POWER SUPPLY 1RU
机架式稳压电源使用说明书
(8路输出路输出)
)【型号【型号】】:PS-DC1212-1U
【输入【输入】】:AC220V/50HZ 【输出【输出】】:DC12V/12.5A(共8组,独立输出)【尺寸【尺寸】】:433mm*220mm *44mm 【净重【净重】】:5KG
【电源型式【电源型式】
】:19”标准机架式,1U,前面板LED 电压指示【电源功能【电源功能】】:每组独立状态指示灯,独立开关控制【应用范围【应用范围】】:弱电系统中摄像机、高速球、探测器或红外灯等设备的电源供应,
及其他设备
【装箱清单【装箱清单】】:
1、1U 机架式电源1台
2、合格证1个
3、使用说明书1份
4、AC220V 电源输入线1条
5、备用保险管若干只
【面板示意图【面板示意图】】:
Front Panel ( 前面板)
Rear Panel (后面板)
【输出电压调节【输出电压调节】】:在机箱内电路板有标着VR 的正方形可调电位器,可用十字螺
丝刀轻轻调节,顺时针旋转电压增高,逆时针旋转电压降低,可根据需要调节。

【保险规格】AC220V 输入3A
DC12V 输出每路1.5A
(可根据需要换装保险规格,但总功率不得超过1212.5.5.5A A )★特别提示:
接入市电时,请特别注意人身安全注意接线端子的正确接法,防止接反不要超负荷使用本产品
如遇故障,不要自行拆卸,请及时联系供应商。

Tripp Lite SU750RTXL2U智能在线无交流时延2U机械室 柜台UPS系统说明书

Tripp Lite SU750RTXL2U智能在线无交流时延2U机械室 柜台UPS系统说明书

Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: ***********************Model #: SU750RTXL2USmartOnline Expandable 2U Rack / Tower UPS System - On-line, double-conversion, sine wave UPS with PDU switching, current monitoring and fault-tolerant auto-bypassHighlights750VA on-line, double-conversion, extended-run 2U rack / tower UPSZero transfer time, on-line, double-conversion operationMaintains sine wave 100/110 or 120V +/-2% output during overvoltages to138V and brownouts as low as 65V (50/60Hz auto-sensing)Simultaneous communications via HID-compliant USB port, serial port,SNMP/Web card slot and EPO interfaceFault-tolerant auto-bypass mode, current monitoring and switched PDU controlvia 2 switchable output load banksInput: NEMA 5-15P (120V); Output; 6 NEMA 5-15R (120V)2 year product warranty / $250,000 Ultimate Lifetime Insurance (USA &Canada only)Description750VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 13.5 inches. Extended runtime available with optional BP24V15RT2U (limit 1), BP24V28-2U (limit 1) or BP24V70-3U(multi-pack compatible) external battery packs. Full-time sine wave 100, 110 or 120V output with +/-2% voltage regulation. Online,double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138. NEMA 5-15P input plug; NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery work-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerantauto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rack & wallmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.Package IncludesSU750RTXL2U Online Double-Conversion UPS SystemPowerAlert Software and cablingMounting hardware for 4-post rack enclosuresInstruction manualFeaturesSmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applicationsTrue on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 100/110/120V (user selectable) under all usage conditionsMaintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer timeRemoves harmonic distortion, fast electrical impulses, frequency variations and other hard-to-solve power problems not addressed by other UPS typesCorrects line voltage conditions as low as 65V and as high as 138V back to selectable 100/110/120V (+/-2%) valuesStandard internal battery set offers 11 min. runtime at half load (300W) and 6 min. at full load (600W)Extended runtime available with optional BP24V15RT2U (limit 1), BP24V28-2U (limit 1) or BP24V70-3U (no limit) external battery packs Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 13.5 inchesShips with all mounting accessories for 4-post rackmount installationOptional 2POSTRMKITWM enables 2-post rackmount or wallmount installationOptional 2-9USTAND accessory enables small-footprint upright tower placementFault-tolerant auto-bypass maintains continuous utility output to connected equipment, even if the UPS suffers internal failure and requires maintenanceNetwork interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slotHID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IPUPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter sutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpointsBuilt-in Emergency Power Off (EPO) interface with cableNEMA 5-15P input plug/NEMA 5-15R output receptaclesIntegrated 2-bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices (each load bank consists of a single outlet)Front panel LEDs offer current monitoring and battery charge level informationUPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required Single-line tel/DSL or network Ethernet line surge suppression2 year manufacturer's product warranty, $250,000 Ultimate Lifetime InsuranceSpecificationsOUTPUT750Output Volt AmpCapacity (VA)600Output Watt Capacity(watts)Output power factor0.8Crest Factor3:1100V; 110V; 120VNominal OutputVoltage(s) Supported120V defaultNominal VoltagedetailsFrequency50 / 60 HzcompatibilityOutput frequency matches input nominal on startup, defaults to 60 Hz on cold-startFrequencycompatibility details+/- 2%Output voltageregulation (line mode)Output voltage+/- 2%regulation (Batterymode)Built-in UPS output6 5-15R outlet(s)receptaclesTwo switchable single-outlet 5-15R load banksBuilt-in controllableswitched load banksBasic PDU options PDU1215 (1U / 13 5-15R outlets); PDUNV (1U / 2 C19, 12 C13 outlets); PDU1415 (0U / 14 5-15R outlets);PDUV15 (0U / 12 5-15R outlets)Metered PDU options PDUMH15 (1U / 13 5-15R outlets); PDUMH15AT (1U / 8 5-15R outlets)*; PDUMV15 (0U / 16 5-15R outlets)Switched PDU options PDUMH15ATNET (1U / 8 5-15R outlets)*; PDUMV15NET (0U / 16 5-15R outlets)External PDU*ATS switch options PDUMH15AT & PDUMH15AT NET support dual UPS and hot-swappable UPS configurations redundancy optionsSine waveOutput AC waveform(AC mode)Sine waveOutput AC waveform(battery mode)INPUT8.6ARated input current(at maximum load)100V AC; 110V AC; 120V ACNominal InputVoltage(s) Supported5-15PUPS input connectiontypeInput circuit breaker15A6UPS Input cord length(ft.)UPS Input cord length1.8(m)15A 120VRecommendedElectrical ServiceBATTERYFull load runtime4 min. (600w)(minutes)11 min. (300w)Half load runtime(minutes)Extended runtime supported via optional external battery packsExpandable batteryruntimeBP24V15RT2U (limit 1); BP24V28-2U (limit 1); BP24V70-3U (multi-pack compatible)External battery packcompatibility24DC system voltage(VDC)Less than 6 hours from 10% to 80%Battery recharge rate(included batteries)Replacement batteryRBC92-2Ucartridge (internalUPS batteryreplacement)Battery Access Front panel battery access doorBattery replacementHot-swappable, user replaceable batteriesdescriptionVOLTAGE REGULATIONOnline, double-conversion power conditioningVoltage regulationdescriptionOvervoltage2% output voltage regulation during overvoltages to 138correctionUndervoltage2% output voltage regulation during undervoltages to 80correction2% output voltage regulation during undervoltages to 65 (under 70% load only)Severe undervoltagecorrectionLEDS ALARMS & SWITCHESLED Indicators14 LEDs indicate line power, online mode, bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing inrack/tower formatsAlarms Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdownconditionsPower-fail alarm can be silenced using alarm-cancel switchAlarm canceloperationSwitches 2 Switches control off/on power status and alarm-cancel/self-test operationSURGE / NOISE SUPPRESSION480UPS AC suppressionjoule ratingInstantaneousUPS AC suppressionresponse timeUPS Dataline1 line TEL / DSL or 10Base T Ethernet protectionsuppressionYesEMI / RFI AC noisesuppressionPHYSICAL4 post 19 inch rackmount (mounting rail kit included)Installation formfactors supportedwith includedaccessories2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND)Installation formfactors supportedwith optionalaccessoriesPrimary form factor Rackmount3.5 x 17.5 x 13.5UPS / Power Moduledimensions inprimary form factor(height x width xdepth / inches)8.9 x 44.4 x 34.3UPS / Power Moduledimensions inprimary form factor(height x width xdepth / cm)Installed wholesystem total rackspace height (rackspaces)2USecondary form factor Tower (requires 2-9USTAND)Installed wholesystem dimensions insecondary form factor(height x width xdepth / inches)17.5 x 3.5 x 13.5UPS dimensions insecondary form factor(height x width xdepth / cm)44.4 x 8.9 x 34.3UPS / Power Moduleweight (lbs)29UPS / Power Moduleweight (kg)13.2UPS Shippingdimensions (height xwidth x depth / inches)9.5 x 20 x 24UPS Shippingdimensions (height xwidth x depth / cm)24.1 x 50.8 x 61Shipping weight (lbs)41Shipping weight (kg)18.6UPS housing material SteelCooling method FanENVIRONMENTALOperatingTemperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees CelsiusStorage TemperatureRange+5 to +122 degrees Fahrenheit / -15 to +50 degrees CelsiusRelative Humidity0 to 95%, non-condensingAC mode BTU / hr.(full load)304.8Battery mode BTU /hr. (full load)332.1COMMUNICATIONSCommunicationsinterfaceUSB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interfaceNetwork monitoring port description Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communicationsPowerAlert software IncludedCommunicationscableUSB and DB9 cabling includedWatchDogcompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applicationsLINE / BATTERY TRANSFERTransfer time No transfer time (0 ms.) in online, double-conversion mode80V (100% load), 65V (Low voltage transferto battery power(setpoint)138High voltage transferto battery power(setpoint)SPECIAL FEATURESCold-start operation supportedCold Start (startup inbattery mode during apower failure)Automatic inverter bypass; Hot swappable batteriesHigh availability UPSfeaturesIndividually controllable load banksGreen & highefficiency featuresCERTIFICATIONSUPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI); Meets FCC Part 68 / Industrie Canada (telecommunications); ROHS (Reduction of Hazardous Substances)WARRANTYProduct Warranty2-year product warrantyPeriod (U.S., Canada& Puerto Rico)$250,000 connected equipment insuranceConnectedEquipment Insurance(U.S., Canada &Puerto Rico)Related ItemsOptional ProductsProduct Type Related Model Description Qty. Power Distribution PDUMH15ATNET Switched, Metered PDU with ATS - Power Distribution Unit with-dual-input Auto Transfer Switching, individual outlet control and remotenetwork interfaceTower Stands2-9USTAND Enables Tower Placement of Rackmount UPS Systems -Shutdown Cable Kits AS400CABLE KIT Power Management Tools - UPS Communication Cable Kit for System-i / AS400 / iSeries ServersSNMP Accessories SNMPWEBCARD For remote monitoring and control via SNMP, Web, or Telnet. --SNMP Accessories ENVIROSENSE Monitors temperature, humidity and contact-closure inputs. (RequiresSNMPWEBCARD or switched PDU.)-Rackmount/Wallmount Kits2POSTRMKITWM Enables 2-Post Rackmount or Wallmount Installation of SelectRackmount UPS Systems-Power Distribution PDUMH15AT Metered PDU with ATS - Power Distribution Unit with dual-input AutoTransfer Switching-Surge Protectors DTEL2Network Surge Suppressor - Essential protection for data andcommunication lines-Power Distribution PDUMH15Metered PDU / Power Distribution Unit - Safe, reliable powerdistribution with digital current meter-Surge Protectors DNET1Network Surge Suppressor - Essential protection for data andcommunication linesPower Distribution PDUMV15Metered PDU / Power Distribution Unit - Safe, reliable power-distribution with digital current meter-Power Distribution PDU1215Basic PDU / Power Distribution Unit - Safe, reliable power distributionfor critical networking equipmentPower Distribution PDU1415Basic PDU / Power Distribution Unit - Safe, reliable power distribution-for critical networking equipment-Extended Warranties WEXT3-500-15003-Year Extended Warranty - For Smart Line-Interactive and OnlineTower or Rack models, 1500VA or lessExtended Warranties WEXT5-500-15005-Year Extended Warranty - For Smart Line-Interactive and Online-Tower or Rack models, 1500VA or lessExternal Battery Packs BP24V15RT2U BP24V15RT2U - External Battery Pack for UPS System -External Battery Packs BP24V28-2U BP24V28-2U - External Battery Pack for UPS System -External Battery Packs BP24V70-3U BP24V70-3U - External Battery Pack for UPS System -More information, including related products, owner's manuals, and additional technical specifications, can be found online at/en/products/model.cfm?txtModelID=3194.© 2010 Tripp Lite. All Rights Reserved.。

  1. 1、下载文档前请自行甄别文档内容的完整性,平台不提供额外的编辑、内容补充、找答案等附加服务。
  2. 2、"仅部分预览"的文档,不可在线预览部分如存在完整性等问题,可反馈申请退款(可完整预览的文档不适用该条件!)。
  3. 3、如文档侵犯您的权益,请联系客服反馈,我们会尽快为您处理(人工客服工作时间:9:00-18:30)。

系统电源控制设备
前面板
1.面板电源输出插座 输出电流10A,此插座默认为直通插座,可根据需要更改为受控插座.
2.电源电压指示(2U) 误差小于1V.
3..直通按键 按下此开关会强制开启所有输出。

此开关为隐藏式设计,以防误操作。

锁定键和状态指示 长按锁定按键,可以锁定/解锁-按键。

指示灯在电平控制、开关 控制状态下常亮,在RS232数据控制状态下闪亮,-设置延时闪亮一次,取消延时闪亮次;锁 定/解锁时,该指示灯闪亮次。

时序开启钥匙 钥匙处于ON时打开时序,处于OFF时关闭时序。

4(2U)5.八路控制按键(2U)及状态指示 亮灯时表示该路有输出,按一次按键转换一次开关状态。

长 按某一个按键,可以将该路设置成关的时候延时10分钟(第七路为10秒)。

同时按下5和6按键, 可以将机器恢复出厂设置。

此8个按键可以被第九个按键锁定,被锁定后,8个按键无效。

6.(2U)181824(4)(仅限于2U )第一和第二路(后板下排1-6插座)带20A 双重净化功能,符合欧洲CISPR 和美国FCC 规范.对需要高品质电源的设备,如音响系统的周边设备(调音台、 均衡器、效果器、无线话筒、DVD 等),医疗设备,精密仪器等,建议使用此六个 插座。

电源净化功能,对于消除系统间电磁干扰,提高音视频设备的信噪比, 保证系统稳定性,有明显的作用。

后面板
L
N
1.级联输入和级联输出口
2.RS232控制输入接口
3.5V输入控制口和短路输入控制口
4.通道1输出插座(共3个,带净化)
5.通道2输出插座(共3个,带净化)
6.通道3-8输出插座
7.接地端子
8.空气开关火线和零线接入端子10.RS232控制输入接口11.四位凤凰接线端子 包含短路触发,5V输入触发, 5V输出触发接口12.1-8路输出插座13.电源输入电缆
1.接入电源
由具备电工上岗资质人员进行操作。

从配电箱取电,根据实际功率要求使用相应线径,推荐使用6平方纯铜电线。

注意:要按照标示,正确接入各电极,不能接错。

本产品为I类电器,务必接地,确保安全。

2.手动控制 开启空气开关,通过机器面板的时序开关(或者钥匙),开启时序电源输出和关闭时序电源输出。

(仅限2U设备)可单独按动1-8按键,控制该路的输出;该路灯亮表示有输出,灯灭表示没输出。

(仅限2U设备)在特殊情况下,按下面板上隐藏的"bypass"按键,可以强制打开1-8通道输出.
3.级联控制 当输出路数不够时,可通过级联扩展,本机可级联2台。

将电脑通过RS232连接到级联主机,在PC软件上将第7路打钩(2U机器可长按面板第7按键)。

PC PC
1U连接图2U连接图软件控制界面
将主机和从机按照下图连接,实现级联完毕。

开启时,主机开启完后,从机跟随开启;关闭时,先关从机, 再关主机。

(注:级联后,主机的第八路不能使用)
4.电压控制 本机可通过外部的5-12V直流电压控制,实现远程管理。

连接图如下:
5.短路开关控制 本机可通过短路开关控制,如墙开关,或者中控的继电器口.
连接图如下:
6.RS232控制 本机提供开放的串口协议(附于后页),可通过PC或者中央控制器编程发码对本机实行灵活的控制 连接图如下:
主机的3/4脚,连接到从机的3/2脚
主机的Link OUT,连接到从机Link IN 直流电压,按正负极接到"5-12V"
直流电压,按正负极接到"REM IN"(1U)墙开关短路开关,接到“RELAY”(2U)(2U)(1U)(1U)
PC
PC
.....
.....
整机功率:50A 60A
规格: 1U 2U
外部控制: 电平控制,短路开关控制,
级联控制,RS232控制同左
直接控制: 开关 钥匙+按键
尺寸: W482xD210xH44(mm ) W482xD280xH88(mm )重量: . .37Kg 50Kg
第一\第二通道共6个输出插座,共
用净化器。

净化器参数:工作电流20A ,泄漏
电流<0.5mA ,二级净化,符合欧
洲CISPR 和美国FCC 规范
安装尺寸:
(1U)
系统电源控制设备用户手册Copyright @ 2014-04-10
Ver 2.0。